aaa-lux al-series gen6 ip65 ik08 - abacus lighting · aaa-lux the aaa-lux al series family of...

5
AAA-LUX The AAA-LUX AL series family of floodlights are a true retrofit for existing 2 kW Metal Halide (2.2 kW power dissipation) floodlights. The white light produced by the luminaire gives a daylight perception, which enhances play at all levels. The Lighting Control Management System (LCMS) can wirelessly switch and dim the luminaires via the proprietary LEDxLINK protocol. In the absence of a LCMS, the luminaires switch on at full power. Equipped with high-quality LED lamps and optics, the light beams are configured to enable sports fields to be illuminated to the levels dictated by the relevant sports governing bodies. The high-quality optics illuminate the sports fields with excellent uniformity whilst producing minimal stray light. The integrated electronic power supply has a high efficiency (greater than 95%), and a power factor (PF) above 0.95. With zero inrush current, the electrical installation can be designed at nominal current, saving significant cabling costs in the case of a new build installation. Boasting a long lifetime and high reliability, all materials used are suitable for outdoor use even in harsh conditions (high temperature versions are available). Benefits Lightest weight on the market at 22kg 5 Year (20,000 hours) warranty as standard for LED and driver Hardened Glass: • Scratch resistant • Long life • Easy maintenance • Clear Class A LED's driven at max. 60%: • Long life • Efficiency > 160lm/W AAA-LUX Optics: • Maximum efficiency • High uniformity Construction: • Stainless steel fastenings • Anti-corrosion double coated aluminimum body Driver Features: Class A capacitors with long lifetime • IP65/66 glands oriented downwards • High efficiency >95% Automatic temperature protection. Protects against over / under voltage. Surge protection 6,000v High power factor >0.9 from 20-100% • No in-rush current - No voltage peak - Reduces total power requirement - Reduced costs Colour: Dark grey powder coated RAL7015 / Pantone 446C Gen6 v Gen5 - Improvements at a glance: • Market leading weight (22-23kg) - Cost savings by mounting on smaller masts / foundations Low profile design results in lower windage Can be retrofitted on a wider range of masts • Rigid construction increases stability Simplified aiming with integral aiming system Modules are locked in position preventing accidental misalignment during handling Redesigned heat sink greatly improves heat dissipation • Communicates with 3 rd party controllers via API AL-Series Gen6 IP65 IK08 DocID: datasheet-AAA-LUX-Gen6-20180521 www.abacuslighting.com

Upload: others

Post on 12-Jul-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AAA-LUX AL-Series Gen6 IP65 IK08 - Abacus Lighting · AAA-LUX The AAA-LUX AL series family of floodlights are a true retrofit for existing 2 kW Metal Halide (2.2 kW power dissipation)

AAA-LUX

The AAA-LUX AL series family of floodlights are a true retrofit for existing 2 kW Metal Halide (2.2 kW power dissipation) floodlights. The white light produced by the luminaire gives a daylight perception, which enhances play at all levels.

The Lighting Control Management System (LCMS) can wirelessly switch and dim the luminaires via the proprietary LEDxLINK protocol. In the absence of a LCMS, the luminaires switch on at full power.

Equipped with high-quality LED lamps and optics, the light beams are configured to enable sports fields to be illuminated to the levels dictated by the relevant sports governing bodies. The high-quality optics illuminate the sports fields with excellent uniformity whilst producing minimal stray light.

The integrated electronic power supply has a high efficiency (greater than 95%), and a power factor (PF) above 0.95. With zero inrush current, the electrical installation can be designed at nominal current, saving significant cabling costs in the case of a new build installation.

Boasting a long lifetime and high reliability, all materials used are suitable for outdoor use even in harsh conditions (high temperature versions are available).

Benefits• Lightest weight on the market at 22kg• 5 Year (20,000 hours) warranty as standard for LED and driver

Hardened Glass:

• Scratch resistant• Long life• Easy maintenance• Clear

Class A LED's driven at max. 60%:

• Long life• Efficiency > 160lm/W

AAA-LUX Optics:

• Maximum efficiency• High uniformity

Construction:

• Stainless steel fastenings• Anti-corrosion double coated aluminimum body

Driver Features:

• Class A capacitors with long lifetime• IP65/66 glands oriented downwards• High efficiency >95%• Automatic temperature protection. Protects against over / under

voltage. Surge protection 6,000v• High power factor >0.9 from 20-100%• No in-rush current

- No voltage peak- Reduces total power requirement- Reduced costs

Colour: Dark grey powder coated RAL7015 / Pantone 446C

Gen6 v Gen5 - Improvements at a glance:

• Market leading weight (22-23kg)- Cost savings by mounting on smaller masts / foundations

• Low profile design results in lower windage• Can be retrofitted on a wider range of masts• Rigid construction increases stability• Simplified aiming with integral aiming system• Modules are locked in position preventing accidental

misalignment during handling• Redesigned heat sink greatly improves heat dissipation• Communicates with 3rd party controllers via API

AL-Series Gen6IP65IK08

DocID: datasheet-AAA-LUX-Gen6-20180521www.abacuslighting.com

Page 2: AAA-LUX AL-Series Gen6 IP65 IK08 - Abacus Lighting · AAA-LUX The AAA-LUX AL series family of floodlights are a true retrofit for existing 2 kW Metal Halide (2.2 kW power dissipation)

AAA-LUXAL-Series Gen6IP65IK08

AAA-LUX BV | CONFIDENTIAL 11

CB2.0 - Control Box 2

Detailed Energy Usage System Health Check

40m standard100m possible

Smart phone / tablet

3rd party controller API

Touch screen network computer

Diagnostics with four levels

Control boxSwitch box

in / out

Stand aloneSwitch boxTIF in / out

AAA-LUX light management system

The system can be remotely monitored from a central location via computer. Wireless push button boxes or proximity sensors at entry gates can send information to the control box to activate the lights or alternatively smart devices can be used to give the same control. These signals are fed into the system and will activate the desired pre-programmed lighting scenes. In case of emergency, all lights can be switched to maximum at the central console. The facility manager can analyse the energy consumption of the system, and optimize between lighting level and energy costs. With a remote access module, an installer can access the system and inspect the luminaires and light management system. Based on luminaire data, maintenance can be scheduled.

Lighting control & WS-Series

When different zones of a site require full lighting levels and others need to be dimmed at different times through the dark hours, the dimmed zones can be brought back up to full lighting levels instantly for emergencies or to allow maximum dimming duration between working time of the zones. This saves energy, keeps running costs low and increases the level of site security.

Energy saving - Total-cost-of-ownership

• Dimmed to the right level• Switched on when needed• Short ROI

DocID: datasheet-AAA-LUX-Gen6-20180521www.abacuslighting.com

Page 3: AAA-LUX AL-Series Gen6 IP65 IK08 - Abacus Lighting · AAA-LUX The AAA-LUX AL series family of floodlights are a true retrofit for existing 2 kW Metal Halide (2.2 kW power dissipation)

AAA-LUXAL-Series Gen6IP65IK08

Technical data

Minimum Typical Maximum Unit

Voltage input 370 400 * 430 VAC

Power factor at 20%-100% 0.90 0.98

Frequency 45 60 Hz

Standby power 5 W

Colour temperature 5,200 K

Colour rendering index 70 80

Weight 22 kg

Ingress protection IP65

Electrical insulation class I

Frontal surface AL60 (tilt) 0.23 (15°) Cw = 1 m²

Frontal surface AL90 (tilt) 0.25 (15°) Cw = 1 m²

Frontal surface AL180 (tilt) ** 0.29 (15°) Cw = 1 0.33 (30°) Cw = 1 m²

Expected lifetime 60,000 100,000 hrs

Power consumption at 100%Standard

High Temperature (HT)1,3751,200

1,4251,250

WW

CurrentStandard

High Temperature (HT)

@ 400VAC 3.53.2

@ 375VAC3.93.5

AA

Ambient operating temperature ***Standard - Heavy Duty

High Temperature-20-20

+40+50

°C°C

Luminous efficacyStandard

High Temperature (HT)103.3114.1

113.1117.2

159.9159.9

lm/Wlm/W

* 230VAC also available upon request ** Windage on WS300 at 30° tilt is worst case *** Absolute maximum temperature 60°C; auto dimming may occur at high temperatures, see below paragraph

The AAA-LUX Gen.6 is tested according to ANSI/UL1598 ISTM (In Situ Temperature Measurement. The built-in temperature protection dims the luminaire automatically, based on the ambient temperature. The graph below shows the maximum luminous output for the different products per ambient temperature and wind still weather conditions. When the product is already dimmed with the LCMS control system, the temperature protection dims only when this dim level is lower than the set dim level.

STD AL/HT

120%

100%

80%

60%

40%

20%

0%-20 -10 0 10 20 30 40 50

Ambient Temperature vs Luminous Flux

DocID: datasheet-AAA-LUX-Gen6-20180521www.abacuslighting.com

Page 4: AAA-LUX AL-Series Gen6 IP65 IK08 - Abacus Lighting · AAA-LUX The AAA-LUX AL series family of floodlights are a true retrofit for existing 2 kW Metal Halide (2.2 kW power dissipation)

AAA-LUXAL-Series Gen6IP65IK08

Definitions

Accessories

Luminaire technical information and dimming-power

Delivered lumen output and power consumption

Standard:STD luminaires are designed for an average ambient temperature of 30°C. The STD can handle high temperatures up to 40°C although it is recommended to switch to the HT version when, during normal operating hours, the ambient temperature is regularly above 30°C in combination with still winds.

Maximum power:Product is optimised for maximum luminous flux (lm) instead of optimal efficacy (lm/W) and cannot be combined with High Temperature option.

High temperature:Product is designed for high temperature environments and cannot be combined with Maximum Power option.

Lifetime:Can only be assured when the system prohibits the luminaires working during daytime (not designed to operate in full sun load)• All sensitive bolts, nuts, washers and mounting clips are

made of Stainless Steel• Light sources are made of corrosion resistant aluminum

with low copper content

Light spill shield:These shields can be used to further reduce light pollution. They can be placed on the individual light beams of the LED luminaire

Aiming visor:A tool for the installation of the LED luminaire

The Gen6 products are available with various beams to accommodate different areas, mast heights and sports fields. For better light spill control, luminaires can be equipped with light spill caps.

Luminaire Type

Standard High Temperature

AL6006 149,774 136,888

AL9006 149,774 136,888

AL1806 142,472 130,685

Luminous flux in lm per lamp type based on DEKRA LM-79 measurement

Intensity (rel. %)

0.90

0.95

1.00

0.85

0.80

0.75

0.70

0.65

0.60

0.55

0.500% 20% 40% 60% 80% 100%

Intensity (rel. %)

1200

1400

1600

1000

800

600

400

200

00% 20% 40% 60% 80% 100%

Intensity vs Power Power Factor vs Dimming

DocID: datasheet-AAA-LUX-Gen6-20180521www.abacuslighting.com

Page 5: AAA-LUX AL-Series Gen6 IP65 IK08 - Abacus Lighting · AAA-LUX The AAA-LUX AL series family of floodlights are a true retrofit for existing 2 kW Metal Halide (2.2 kW power dissipation)

AAA-LUXAL-Series Gen6IP65IK08

Dimensions (mm)

Polar intensity diagrams

310

840 660

ø22

175

Maximum fixture dimensions including mounting bracket: 840 x 660 x 310

DocID: datasheet-AAA-LUX-Gen6-20180521www.abacuslighting.com