D-dimer level remains a highly sensitive test for acute aortic dissection beyond the first 24 hours after onset AATS Aortic Symposium 2010 New York April 29-30, 2010 Scott A. LeMaire, Ludivine Russell, Neal R. Barshes, Paul M. Allison, Dana E. Haas, Ying H. Shen, Dianna M. Milewicz, Joseph S. Coselli This study describes an unlabeled/investigational use of the Siemens Advanced D-dimer Assay, i.e. for the diagnosis of acute aortic dissection.

Upload: ebony

Post on 04-Jan-2016

32 views

Category:

Documents


0 download

DESCRIPTION

D-dimer level remains a highly sensitive test for acute aortic dissection beyond the first 24 hours after onset. Scott A. LeMaire, Ludivine Russell, Neal R. Barshes, Paul M. Allison, Dana E. Haas, Ying H. Shen, Dianna M. Milewicz, Joseph S. Coselli. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

D-dimer level remains a highly sensitive test for acute aortic dissection beyond the first 24

hours after onset

AATS Aortic Symposium 2010 ▪ New York ▪ April 29-30, 2010

Scott A. LeMaire, Ludivine Russell, Neal R. Barshes, Paul M. Allison,

Dana E. Haas, Ying H. Shen, Dianna M. Milewicz, Joseph S. Coselli

This study describes an unlabeled/investigational use of the Siemens Advanced D-dimer Assay, i.e. for the diagnosis of acute aortic dissection.

Page 2: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Study Objective

• D-dimer has been proposed as a highly sensitive biomarker to detect acute aortic dissection

Elefteriades et al ▪ Cardiology 2008

• Recent data from the International Registry of Acute Aortic Dissection Substudy on Biomarkers (IRAD-Bio) show that D-dimer levels obtained within the first 24 hours after symptom onset had a 96.6% sensitivity

Suzuki et al ▪ Circulation 2009

Page 3: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Study Objective

• Some patients, particularly those with atypical symptoms, present for evaluation beyond the first 24 hours after onset of acute aortic dissection; it is unclear whether D-dimer levels would be useful in detecting dissection in these patients

• The purpose of this study was to determine whether D-dimer levels remain elevated more than 24 hours after the onset of acute aortic dissection

Page 4: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Methods

• Institutional approval was obtained for the study, and written informed consent was obtained from all patients

• Plasma samples were collected within 10 days after onset of symptoms from 100 patients with unrepaired acute aortic dissection

• Whenever possible, serial samples were obtained over a period of 2 or more days

• Samples were grouped according to day of collection relative to the onset of aortic dissection; an average of 25 samples were available for each day’s group, from day of onset (day 0) through post-dissection day 10

Page 5: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Clinical Features

VariablePatients

(n = 100)

Age (yrs), mean ± SD 56 ± 14

Men 61

Hypertension 62

Coronary artery disease 4

Diabetes 10

Chronic obstructive pulmonary disease 11

Smoking (past or current) 54

Marfan syndrome 15

Cancer 3

Page 6: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Dissection Characteristics

VariablePatients

(n = 100)

DeBakey classification: Type I Type II Type III

501238

Classic aortic dissection 94

Intramural hematoma 6

Penetrating atherosclerotic ulcer 0

Drug-induced aortic dissection 1

Iatrogenic aortic dissection 1

Aortic rupture 9

Page 7: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Methods

• D-dimer levels were measured in the clinical laboratory by using the Siemens Advanced D-dimer assay (latex-enhanced immunoturbidimetric assay) on an automated coagulation analyzer BCS XP (range of detection, 0.4-55 µg/mL)

• The approved cut-off for detecting venous thromboembolism for this assay is 1.6 µg/mL; this value was used as the diagnostic threshold

• A post-hoc subgroup analysis was performed to explore whether clinical factors were associated with false-negative D-dimer levels in this cohort

Page 8: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Results

• The median D-dimer level for all plasma samples (n = 279) was 3.56 µg/mL (interquartile range, 2.55-5.60 µg/mL)

• D-dimer levels exceeded the 1.6 µg/mL diagnostic threshold in 266 samples, yielding an overall sensitivity of 95.3%

D-d

imer

lev

els

(μg

/mL

)

40.0

35.0

30.0

25.0

20.0

15.0

10.0

5.0

0.0

1.6 µg/mLthreshold

Page 9: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

D-dimer levels remained markedly elevated throughout the 10-day post-dissection period; daily sensitivities ranged from 89 to 100%

Days after onset 0 1 2 3 4 5 6 7 8 9 10

n 7 27 26 33 26 27 27 30 31 21 24

Sensitivity 100% 89% 89% 94% 100% 100% 96% 97% 97% 95% 96%

1.6 µg/mLthreshold

D-d

imer

lev

els

(μg

/mL

)

40.0

35.0

30.0

25.0

20.0

15.0

10.0

5.0

0.0

Page 10: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

FactorFalse-negative Rate

(D-dimer ≤ 1.6 µg/mL)P

HypertensionYes

No

5/190 (3%)

8/89 (9%)0.02

Coronary artery diseaseYes

No

4/20 (20%)

9/259 (3%)0.009

DeBakey type

I

II

III

2/84 (2%)

4/21 (19%)

7/174 (4%)

0.004

Intramural hematomaYes

No

1/17 (6%)

12/262 (5%)0.6

• False-negative results were significantly more common in samples obtained from patients without hypertension, with a history of coronary artery disease, or with DeBakey type II dissection

• False-negative results did not appear to be related to patient age, intramural hematoma (vs classic dissection), Marfan syndrome, smoking, or cancer

Page 11: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

Conclusions

• Elevated D-dimer levels remain a sensitive indicator of acute aortic dissection throughout the first 10 days after onset

• Post-hoc analysis showed that the sensitivity of D-dimer may be reduced in certain subsets of patients, such as those with dissection involving only the ascending aorta (ie, DeBakey type II)

• Although D-dimer testing may be helpful in detecting acute aortic dissection in patients with delayed presentation, further studies are needed to evaluate the impact of clinical factors on the sensitivity of this assay

Page 12: AATS Aortic Symposium 2010  ▪  New York  ▪   April 29-30, 2010

• Dr. LeMaire is supported by a Thoracic Surgery Foundation for Research and Education/National Heart, Lung and Blood Institute Co-sponsored Mentored Clinical Scientist Development Award (K08 HL080085)

• The Thoracic Aortic Disease Tissue Bank at Baylor College of Medicine is supported in part through the NIH Specialized Center for Clinically Oriented Research in Thoracic Aortic Aneurysms and Dissections (P50 HL083794; DM Milewicz, PI)

Acknowledgements