absolute filters for iso5011-layout 1filteq.com/images/absolute_filters_for_iso5011.pdfnew absolute...
TRANSCRIPT
air- inlet
air- outlet
when door is opened, sealing gasket is released -> filter can easily be taken out of the housing
New Absolute Filter for Test Benches According to ISO 5011for Inlet Air Cleaning Equipment for Internal CombustionEngines and Compressors (replaces plane round filters)
- two versions for flow ranges up to 20 or up to 30 m3/min -> quick mounting and removal of filter (approx. 90 % time saving) -> no dismounting of test bench for weighing of absolute filter -> handling from both sides -> saving costs through multiple usage of absolute filter -> low tara of filter cartridge (approx. 600 g) for exact weighing
FilTEqFiltration Testing Equipment & Services GmbH
www.filteq.com Amthausstr. 14 Tel.: +49-(0)[email protected] D-76227 Karlsruhe Fax: +49-(0)721-406545
*FILTER TESTING*DATA ACQUISITION*GAS CLEANING*POWDER HANDLING and DISPERSING*
by closing the door, seal gasket of filter cartridge is tightened automatically
seal for filter frame
axial skid
bracket for pressing of the filter frame - closed
bracket for pressing on the frame of filter cartridge - filter can be removed for weighing when opened
two handle for easy opening from both sides
Ring line for differential pressure measurement
spring bolt improved guidance to slide in filter (on both sides)
skid is moved to release seals by springs when door is opened
clamping door lock to tighten door seals (hight adjustable)
gas flow in
bracket for pressing on frame of filter cartridge
gas filled damper to prevent falling shut of door (safety device)
connectors for pressure drop measurement
bracket to seal filter cartridge and ring line with 4 openings for pres- sure drop measurement
socket for proximity switch to
prevent start of blower when door is open
proximity switch
improved guidance to slide in filter (on both sides)