absolute isotopic abundance of terrestrial silver

3
JO URNAL O F RESEARC H of the Nati onal Bureau of Sta ndar d s-A. Physics a nd Che mi stry Vol. 66A, No. I, January-Feb ruary 1962 Absolute Isotopic Abundance of Terrestrial Silver* William R. Shields, Ernest 1. Garner, and Vernon H. Dibeler (September 28, 1961) I soto pic ab und ance ratios are r epo r te d for a commercial sil ver nitr at e, 13 sa mpl es of nat ive silver, a nd 11 silver min erals of variou s co mp ositions an d fr om widely di st ribu ted depo sits. Co ll ateral meas ur ements of known mi xt ur es of n early pure s il vel' isotopes permit the d ete rmin at ion of absolute ab und ance rat ios. Nativ e silver from Cobalt, Ontario, pr eviously repor te d as exhibit in g s tat istically s ig nifi ca nt vari at ion, is re-e xam in ed. Addi- tional meas ur eme nt s are reported for sa mples from the same nugget a nd fr om the s ame region. Except for the origina l observ at ion, no sign ifi ca nt variation from normal a bund ance is observed for any of the samples. Th e AgI 07( Agl OO r at io obta in ed from pooling the data is 1.07597 with a 95 per ce nt confidence limi t of ± 0.00055 for the eff ect of ra nd om e rr o rs a nd a total uncer ta in ty of ± 0.001 35 wh en an all owa nce for the possible e ff ects of known sources of sys tematic error is includ ed. 1. Introduction In a recent d etermin at ion of the absolu te isoto pi c ab undan ce ratio of silver, Shi elds, Craig, a nd Dib e- ler [IF carefully measured the AgI07 jAg109 ratio for several sampl es of n ati ve silver. Th ey reported a sta Li stica ll y sig nifi ca nt variation in the ratio for one sa mpl e from Coba lt, On tario compar ed with six sa mpl es from other lo calities. Pr evious in vest iga- Lions of a possible var iat ion in the isotope ratio of naLural silver h ave been limi ted to pro cessed bulk s il ver [2] or to a ver:\T few min eral sampl es . I- less , Marshall, a nd Dr ey [3] h ave reported no vari at ion among four sampl es of ter rest rial silver a nd one sample of Tolu ca Troili te. However, their limit for detect ion of variation was a bou t 2 percent of the isotope rat io. MurLhy [4] h as r ecently m ade a more precise compari son of Tolu ca Troili Le with com- mercial silv er nitrate a nd finds abo ut a 2 percent enrichment of AgI07 in the troilite. As the a pp arent variation reported for Cobalt silver is only a fra ction of this amount , a car ef ul re-examination has been made of native sil ver sampl es, including some from the Cobalt ar ea . In a ddi tion, meas ur eme nt s h ave been mad e on a number of silv er min erals from widely scattered deposits to provide a bro ad er basis for establis hin g a limit to the n at ur al vari at ion in the isotope abundance of terrestrial silver. 2. Experimental Procedure Th e mass sp ectrom eter used in this re search is a 12-in . ra dius-of- curvatur e, 68° deflection with 60° magnet, single focusing, sur face emi ssion ins trument . Th e triple fil ament source uses all rhenium ribbon s 1 X 30 mils. Th e usual techniques were employe d for pr ep aring sampl e filaments for surf ace emission using of the order of 100 J.Lg of sampl e. No extra- neous mater ial was r equire d or used to produ ce sat- isfactory emission char acter istics for Ag+ ions. ·Thi s work was supported in part by tbe U.S. Atomic Energy Commi ssion. I F igures in brackets indicate the lit erature references at tbe end of this paper. 1 Ion c urr enLs were measured with a vibrating reed el ectro m eter. I sotope r atios were meas ur ed both by co mp ari son of Lbe Ag lO7 a nd Ag lO9 ion c urr ents col- l ecte d a lt ernately on the Faraday coll ector and by a r at io-record m ethod using an expand ed scale re- cord er .2 All ratio measurements of the calibr at ion mixtures an d the commercial a nd natural samples were ob- tained und er standardized conditions of essent ially con stant sample size and nomin al ion curr ents of 1 X 10- 11 amp. Th e l atter was controlled by a dju st- ment of the filamen t temperat ur es. Observations were made on a s tr i ct ti me schedu le as illu strat ed in figure 1. The pl ot re pr esents a typical set of un cor- rected cia ta for eight analyses of a commercial il ver nitrate. Each analysis consists of t hr ee ratios ob- se rved at la-min intervals starting 20 min af ter fil a- men ts are t urn ed on. C ur ve A re pr esent s the set of ' Thi s circuit and other detail s of con structi on of the instrument used in tbis wo rk will be pllbJished elsewhere. o 0:: .. o - ... .. .. 2 1.085 .-- -,- -- ..... :: 1.080 o ... I- U ... 0:: 0:: o U z :> 1. 075 '--__ ......... __ -'-__ ---1. ___ .L...-__ ..l.-__ ..J o 20 40 TIME ,min FI GURE 1. Typi?al ratio measurements for commerC'tal szlver mtrate as a function of time. 60 Of ei gbt analyses, curves A and B represent tbe higb es t and lowest observed ratIOS, respectively. Curve C represent s tbe average of all eight analys es.

Upload: others

Post on 22-Dec-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

JO URNAL OF RESEARCH of the National Bureau of Standards-A. Physics a nd Chemistry Vol. 66A, No. I , January- February 1962

Absolute Isotopic Abundance of Terrestrial Silver* William R. Shields, Ernest 1. Garner, and Vernon H. Dibeler

(September 28, 1961)

I sotopi c abundance ratios a re reported for a commercial silver ni t rate, 13 sa mples of native silver, and 11 silver min erals of various compositions an d from widely dis tributed deposits . Collateral measurements of known mi xtures of nearly pure sil vel' isotopes permit the determination of a bsolu te abundance rat ios. Native silver from Cobalt , Ontario, prev iously r eported as ex hibi t in g s tatist ically s ignifican t vari ation, is re-examin ed. Addi­tional measurements a re repo rted for samples from t he sa me nugget a nd from t he same region. Except fo r the original observation, no sign ificant variation from normal a bundance is observed for any of the sa mples. Th e AgI 07(AglOO rat io obtain ed from p oolin g t he data is 1.07597 wi th a 95 perce nt co nfidence limi t of ± 0.00055 for t he effect of ra ndom erro rs a nd a total uncer tain ty of ± 0.00135 when an allowance for the possible effects of known sources of sys tematic error is in cluded.

1. Introduction

In a recent determination of th e absolu te isotopic ab undance ratio of s ilver , Shields, Craig, and Dibe­ler [IF carefully m eas ured th e AgI07jAg109 ratio for several samples of native silver. They reported a staListically significant variation in the ratio for one sample from Cobalt, On tario compared with six samples from other locali ties . Previous investiga­Lions of a possibl e variation in the isotope ratio of naLural silver h ave been limited to processed bulk silver [2] or to a ver:\T few min eral samples . I-less , Marshall , and Drey [3] h ave reported no variation among four samples of ter restri al silver a nd one sam ple of Toluca Troilite. However , their limi t for detection of variation was about 2 percent of the isotope ratio. MurLhy [4] has recently m ade a more precise comparison of T oluca TroiliLe with com­mercial silver nitrate and finds about a 2 percent enrichment of AgI07 in the troilite . As the apparent variation reported for Cobalt silver is only a fraction of this amount, a careful re-examination h as been m ade of native silver samples, including some from t he Cobalt ar ea . In addition, measurements h ave been made on a number of silver minerals from widely scatter ed deposits to provide a broader basis for establishing a limit to the n atural variation in the isotope abundance of terrestrial silver.

2 . Experimental Procedure

Th e mass spectrometer used in this research is a 12-in . radius-of-curvature, 68° deflection with 60° magnet, single focusing , surface emission ins trument. The triple filament source uses all rhenium ribbons 1 X 30 mils. The usu al techniques were employed for preparing sample filaments for surface emission using of the order of 100 J.Lg of sample. No extra­neous material was r equired or used to produce sat­isfactory emission characteristics for Ag+ ions.

·This work was supported in part by tbe U.S. Atomic Energy Commission. I Figures in brackets indicate the literature references at tbe end of this paper.

1

I on currenLs were m easured with a vibrating reed electrom eter. I sotope ratios were m easured both by comparison of Lbe AglO7 and AglO9 ion currents col­lected alternately on the Faraday collector and by a r atio-record method using an expanded scale re­corder .2

All ratio measurements of the calibration mixtures and the commercial and natural samples were ob­tained under standardized cond itions of essentially constant sample size and nominal ion currents of 1 X 10- 11 amp. The latter was controlled by adjust­ment of the filamen t temperatures. Observations were made on a s trict t ime schedule as illustrated in figure 1. The plot represents a typical set of uncor­rected cia ta for eigh t analyses of a commercial ilver nitrate. Each analys is consists of three ratios ob­served at la-min intervals starting 20 min a fter fil a­men ts are turned on. Curve A represents the set of

' This circuit and other details of construction of the instrument used in tbis work will be pllbJished elsewhere.

o

~ 0:: ..

o -... .. .. 2

1.085 .---,---..... --~---,.....----r---~

:: 1.080

o ... I-U ... 0:: 0:: o U z :>

1.075 '--__ ......... __ -'-__ ---1. ___ .L...-__ ..l.-__ ..J

o 20 40 TIME , min

F I GURE 1. Typi?al un~o1"rected ratio measurements for commerC'tal szlver mtrate as a function of time.

60

Of eigbt analyses, curves A and B represent tbe higbest and lowest observed ratIOS, respectively. Curve C represents tbe average of all eight analyses.

data with the highest observed A gI07j A gI09 ratios, TABLE 1. Native Silver Samples curve B represents the lowest ratios, and curve C represents the average ratios of all eight analyses. A variation in abundance ratio with time is observed. Mass spectra were obtained by varying the magnetic field by means of a reversible motor-driven control Helipot.

Except as otherwise indicated, the natural silver samples were obtained from collections of the U.S. National Museum, Smithsonian Institution through the courtesy of Paul E. Desautels and selected by Thomas W. Stern of the U .S. Geological Survey. D etails of the preparation and measurement of the

U.S.N.M. Catalog No.

._---------.--65154.. _______

5791.. ________

81781.. .. ____ .

112858 .. __ .. __

C-162 ________ 62845.. _______

Composition

Silver Nitrate ___

Nati\~e Silver ____

Native SilvcL ...

Native Silvpr ____

Native Silver .'"

Native Silver __ __ Native Silver. _ ..

Locality AgiO/lAg'" Analytical error a

Commercial materi- 1. 0755 0.0013 allot 90138

Silver King Mine, Pina lOo.,Arizona

1. 0734

Ontouagon , Lakc 1. 0766 Superior District, Mich.

GagnonMine, Butte Mont.

1. 0744 .0025

El Mochito Honduras

Mine, 1.0746

Chihuahua, Mexico 1. 0755 Kongsberg, Norway 1. 0744

native silver samples and of the calibration mixtures & This uncertainty is tbe 95 percent confidence limit for the effect of random of nearly pure isotopes are given by Shields, et al. , errors intbe an alyticalprocedure.

[1]. The mineral samples were prepared for analy-sis by Rolf A. Paulson using well-known procedures TABLE 2. Cobalt Silver Samples and taking care to prevent contamination or sepa­ration of isotopes during the solution process. No effort was made to purify mineral samples to better than 80 percent silver. Native silver samples were not purified.

3. Results and Discussion

Tables 1, 2, and 3 summarize the data for the various silver samples examined in this study. Col­umn 1 gives the U.S. National Museum catalog number, when applicable. Columns 2 and 3 identify the ore and locality, respectively. Column 4 lists the absolute A gI07JA gI09 ratios and column 5 gives the 95 percent confidence limit for the effect of ran­dom errors in the analytical procedure. The data for silver nitrate reference obtained with each group of samples is given in each table.

The native silver samples of table 1 were analyzed by mass scanning. Each sample was analyzed four times with eighteen ratio pairs taken within each analysis. The mineral silver samples in table 3 were analyzed with a ratio recording measuring circuit. Each sample was analyzed twice with three ratios observed at 10 min intervals for each sample. Co­balt samples (1), (2), and (3) of table 2 were analyzed with the ratio recording measuring circuit and all other samples were analyzed by mass scanning.

The high value for the cobalt (1) sample (table 2) must remain unreconciled. The nugget from which this sample was cut is part of a private collection donated to the National J\!(useum and some uncer­tainty must be attributed to its origin. However, the isotope ratio of the two samples subsequently obtained from the same nugget are in accord with all other silver samples. Thus, the average of these three samples (1.0764) is taken as the value repre­sentative of the silver from this area.

It is apparent that the observed differences among all samples are less than expected on the basis of random errors associated with the measurements. Therefore, all samples must be regarded as having the same isotope abundance ratio within these limits (0.2 percent of the ratio). Nevertheless, it is inter­esting to note that in general the isotope abundance

2

U.S.N.M . Composition Locality AgIO//Agl" Analytical Catalog No. errOr "

-------------- Silver Nitrate ___ Commercial materi- 1.0763 0. 0009 allot 90138

C- 140 (1)' ___ Native Silver ____ Cobalt, Canada

Ontario, 1. 0783:-(1)

C- 140 (2)' ___ Native Silver ____ Cobalt, Canada

OntariO, 1. 0i58 (2) . 0015 C-140 (3)' ___ Native Silver __ .. Cobalt,

Canada Ontario, 1. 0753 (3)

._------------ Native Silver b .. Silver Miller Mine, 1. 0746

) Cobalt Camp

- ------------- Native Silver b __ Nova Scotia Mine, 1. 0743 Cobalt Camp .0025

-------------- Native Silver b __ Silver Banner Mine, 1.0736 Cobalt Camp

-------------- N ative Silver b __ Grea t Bear Lake, 1. 0745

• Three chips cut from different sides of t he same nugget. b Kindly supplied by tbe Canadian Geological survey through Dr. Frank E .

Senftle, U.S.G.S. o See footnote to t able 1.

TABLE 3. Mineral Silver Samples

U.S.N .M . Composition Locality Ag lO7/AglO' Analytical Catalog No. error a

-------------- Silver Nitrate Commercial mate- 1. 0758 0. 0008 rial, lot 90138 80263 ___ ______ Bromyrite Australia 1. 0752

R- 1215 _______ Cerargyrite Arizona 1. 0750 R-I226 _______ Embolite Australia 1. 0756 C-8] 6 ________ Frei bergi te Bolivia 1. 0754 9604L. _______ Naumannite Idaho 1. 0751 C-330 ________ Hessite Transylvania 1. 0754 . 0015. 62877 _________ Argentite Germany 1. 0752 R- 1144 _______ Polybasite M exico 1. 0743 C- 5638 .. ____ . Stephanite Germany 1.0757 9525.. ________ Pyrargyrite Germany 1. 0750 92933.. _______ Proustite Ch ile 1. 0746

Silver nitrate summary Analytical Total un-

error a AgI07/AgI"

certainty b

Shields, Craig, and Di-beler (1960) 1. 07547 ±0.00126 ±0.OO206

Poolcd data- present work 1. 07597 ± 0.OOO55 ± 0.00135

• See footnote to table 1. b Analytical error plus an allowance for possible eflect due to known sources of

systematic error.

ratios for natural silver samples are lower than that of the commercial silver nitrate. This is presently attributed to the lower silver purity in the natural samples compared with the chemically pure silver nitrate from the commercial and calibration samples.

IL has been observed consistently that the AgI07/AgI09 mtio for a given sample regardless of origin 'was low if any difficulty was experienced in obtaining the standardized intensity level for the Ag+ion current or otherwise required higher-than .. normal filam ent te m.peratures.

1'he proper means of obtaining the "best estimate" of t he Ag107/AgI09 ratio is not obvious. However, t he total number of measurements of the commercial silver nitrate, lot 90138, greatly exceeds all other samples. Furthermore, this material is isotopically indistinguishable from the other samples. If all the inform ation observed to date for the commercial sil­ver nitrate is pooled, the unbiased estimate of Ag107/ AgI09 = 1.07597. The 95 percent confid ence limit for the effect of random errors on this combined value is ± 000055. This limit of error plus a limit for possi-

3

ble systematic error gives the overall limit for the Ag/107/AgI09 ratio of ± 0.00135. The value for the ratio does not differ significan tly from that previously reported by Shields et fll. , but can be tated 'with a smaller uncertainty.

4. References

[1] W. R. Shields, D . N. Craig, and V. H . Dibeler, J. ArneI'. Chern . Soc. 82, 5033- 5036 (1960).

[2] E. A. C. Crouch, E . R. Preece, 1. G. Swainbank, and A. H. Turnbull, Nature 184, No. 4683 (Suppl.), 358 (1959) .

[3] D . C. H ess, It. R . Marshall, and H. C. Urey, Science, 126, 1291- 1293 (1958).

[4] U. R . Murthy, Phys, Rev . Letters 5, No. 12, 539- 541 (1960) .

(Paper 66Al- 135)