ac current probe with rogowski coil

2
AC Current Probe with Rogowski coil FEATURES APPLICATIONS The RCP current probe is based on a rogowski coil which is small, lightweight and can be tied around conductors without breaking the current path. The current sensor is attached to the amplifier box, thus lacking the typical coaxial cable that usually clutters measurement setups. A version with a 20 cm pigtail between coil and transducer is also available, see picture in the “Ordering Codes” section. Coil attached to amplifier box or pigtail options Rogowsky coil with 2MHz bandwidth transducer 500A, 1000A, 2000A models, optional customisation Low noise Output BNC, user selects cable length Battery powered, connects to any oscilloscope Rev 2. [email protected] www.saker-mv.com Power inverters Power quality General AC current measurements Testing of motors

Upload: others

Post on 13-Apr-2022

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AC Current Probe with Rogowski coil

AC Current Probe with Rogowski coil

FEATURES

APPLICATIONS

The RCP current probe is based on a rogowski coil which is small, lightweight and can be tied around conductors without breaking the current path. The current sensor is attached to the amplifier box, thus lacking the typical coaxial cable that usually clutters measurement setups. A version with a 20 cm pigtail between coil and transducer is also available, see picture in the “Ordering Codes” section.

▪︎ Coil attached to amplifier box or pigtail options▪︎ Rogowsky coil with 2MHz bandwidth transducer▪︎ 500A, 1000A, 2000A models, optional customisation▪︎ Low noise▪︎ Output BNC, user selects cable length▪︎ Battery powered, connects to any oscilloscope

Rev 2. [email protected] www.saker-mv.com

▪︎ Power inverters▪︎ Power quality ▪︎ General AC current measurements▪︎ Testing of motors

Page 2: AC Current Probe with Rogowski coil

SPECIFICATIONS

Specifications subject to change. * Risetime measured, at BNC output using no pigtail

ORDERING CODES

RCP Specification RCP500 RCP1000 RCP2000 Units

Bandwidth(*) 2Hz…2MHz 2Hz…2MHz 2Hz…2MHz

Sensitivity 10 5 2.5 mV/A

Maximum measurable current A

Measuring delay 160 160 160 ns

Overall error (sensor positional error included)

%

Output connector BNC BNC BNC

Receiver output range V

Measuring instrument minimum input impedance

100 100 100

Output noise 2 2 2 mVrms

Current consumption 30 30 30 mA

Batteries 2x1.5V AA 2x1.5V AA 2x1.5V AA

Low battery threshold voltage 2.2 2.2 2.2 V

Coil AC insulation test, 50 Hz 1 min 3.5 3.5 3.5 kVrms

Measurement category (with no insulation in the current carrying conductor)

300V Cat III600V Cat II

300V Cat III600V Cat II

300V Cat III600V Cat II

Rogowski enclosed circular conductor diameter, max

71 71 71 mm

Rogowski enclosed planar busbar dimensions, max

100x10 100x10 100x10 mm

Working temperature -20…+60 -20…+60 -20…+60 ºC

Max. operating humidity, non-dondensing

85 85 85 %

Dimensions See dimensions section See dimensions section See dimensions section

1060±

5.3±

2120±

5.3±

< 2±

5.3±

< 2±

530±

< 2±

CODE Description

RCP500 RCP500 current probe, 500A range, including 2m BNC to BNC cable

RCP500P RCP500 current probe with 20cm pigtail cable between coil and transducer, 500A range, includes 2m BNC to BNC cable

RCP1000 RCP1000 current probe, 1000A range, includes 2m BNC to BNC cable

RCP1000P RCP1000 current probe with 20cm pigtail cable between coil and transducer, 1000A range, includes 2m BNC to BNC cable

RCP2000 RCP2000 current probe, 2000A range, includes 2m BNC to BNC cable

RCP2000P RCP2000 current probe with 20cm pigtail cable between coil and transducer, 2000A range, includes 2m BNC to BNC cable

Rev 2. [email protected] www.saker-mv.com