acccata_full_1
DESCRIPTION
http://www.hzvivalve.com/documents/ACCCata_Full_1.pdfTRANSCRIPT
HZVI Actuators Accessories
Limit switch
Features
- Independent installation of switches makes maintenance and replacement convenient.
- Firm and compact design Die-casting aluminum and plastic body
- Quick cam mechanism The cam i s fixed by springs can be set without need of tools and need no adjustment after the initial setting.
- Convenient for installation The NAMUR standard stainless steel shaft and bracket Reasonable design and convenient installation of the bracket connecting hole.
Specifications
Model BAPL-310 BAPL-410
Standard Option Standard Option
Protection Waterproof IP67 Waterproof IP67 Ex dII BT6
(EN50014/50018)
Shell material l Die-casting aluminum
Environment -25~85 ℃
Wiring end 2X1/2" NPT PT1/2"
PF1/2"
2X3/4"NPT PT3/4"
PF3/4"
Terminal Block 8 9~24 8 9~24 0~90 degree 0~180 degree 0~90 degree 0~180 degree
Position
indication Off: red On: yellow
Switch Mechanical switch Proximity switch Sensor switch
Position
Indication Unit 1k Ohm (0~5k Ohm ,0~10k Ohm)
Current feedback 4~20mA (20~4mA)
Model BAPL-210 BAPL-510
Standard Option Standard Option
Protection Waterproof IP67 IP68 Waterproof IP67 NEMA 4 4X
Shell material Die-casting aluminum Plastic
Environment -20~80 ℃ -15~80℃
Wiring end 2X1/2" NPT PT1/2"
PF1/2"
PGB.S
1/2"NPT
Terminal Block 8 points(0.08~0.25mm) Standard PCB 6 0~90 degree 0~180 degree 0~90 degree 0~180 degree
Position
indication Off: red On: yellow
Switch Mechanical switch X2
Proximity switch X2
Mechanical SPDT silver plated
Mechanical SPDT gold plated
Proximity NAMUR switch
Size Drawing
BAPL-310
BAPL-410
Size Drawing
BAPL-210
BAPL-510
Technical specification
Filter Regulator
Model
AFC2000
Ac2000
BFC3000
Bc2000
Working Medium
Air
Pull pipe bore
1/4"
3/8"
Filter element precision
40µm
Applicable pressure range
Manual drainage: 0.05~0.85Mpa
Max. adjustable pressure
0.95Mpa
Guaranteed pressure
1.5Mpa
Applicable temperature
5~60℃
Capacity filter cup
15CC
Capacity of oil feeding cup
25CC
Recommended lubricating oil
ISO VG32 or same level oil
Weight
0.7kg
0.5kg
0.7kg
Components
Filter
AF2000
AFR1500
AF3000
AFR2000
Pressure
regulating
valve
AR2000
AR3000
Oil feeder
AL2000
AL2000
AL3000
AL3000
Filter Regulator
Installation Please clean the connecting pipe and joint to avoid dust to enter gas circuit while installing. Please note whether the direction of gas flow is in accordance with arrow direction on the body and whether the gear form of connecting pipe and joint is correct or not. Fastness between filter, voltage regulating circuit (voltage regulating filter) and oil feeder: Match the bulge on stationary barrier with the groove on the body and then lock them up by stator and screw. Fastness while using high voltage valve and voltage regulating filter alone: circumvolve the fixed loop to lock the accessory stator tight.
Water discharging (filter) There are two modes for water discharging of the filter, automatic and manual. Manual: Water must be discharged before water level comes to filter element.
Voltage Regulation (Voltage Regulating Valve) Please draw back the rotary knob and then circumvolve it. Pressing the rotary knob means orientation. Turning the rotary knob right is to raise the exit pressure and turning the rotary knob left is to lower the exit pressure. While regulating the voltage, evenly adjust to the wanted pressure value step by step. It cannot be adjusted right the first time. Methods of oil feeding and Regulation of oil mass (oil Feeder) JISK2213 Transmission oil (ISO VG32 or same level oil) is applied for oil feeder. Oil mass should not be more than 80% of the cup. Number 0 is the minimum, 9 is the Maximum. The alignment point of number is arrow direction. It cannot be circumvolved from 9 to 0 position and It must be circumvolved clock wise.
Cautions Some accessories are made of PC material. It is not allowed to be near or used in any organic solvent. The PC cup must be cleaned by neutral detergent. Applying Voltage is not more than 0.95Mpa. Replace the filter element when the air flow at exit decreases obviously.
Solenoid Valve
Features The solenoid valve directly install the pneumatic actuators, only need to connect the air supply, save the pipe line connection. It adopt the same installing standard, it can connect with different bore solenoid and different factory’s solenoid valve.
Operating principle
Technical specifications - Change direction time (S): <0.05 - Pull Pipe thread: G1/2", G1/4", G1/8" - Resistance test pressure: 1.2MPa
2W511-0.8 2W512-0.8 2W511-10 2W512-10
2W521-0.8 2W522-0.8 2W521-10 2W522-10
Working medium Air (Filtered with 40µm filter screen )
Acting type Internal Pilot type
Positional
number 5/2 Channel or 3/2 channel
Effective cross-sectional
area 16mm2(CV=0.78) 30mm2(CV=1.68)
Pull pipe bore Air inlet=1/8" Air outlet=1/8" Air inlet=1/4" Air outlet=1/4"
lubrication No need
Using pressure 1.5~8.0kgf/cm2(21~114Psi)
Max 12Kgf/cm2(170.6Psi)
NUMAR STANDARD
5/2 channel 3/2 channel
Solenoid Valve
Technical specifications
Resistance
pressure
Working
temperature 5~60℃(41~140F)
Voltage range +_10%
Electricity
consumption AC:4.5VA DC:3.0W
Insulativity F class
Protection
class IP65(DIN40050)
Electrical
connection Terminal Type
The maximum
acting frequency 5 times/S
The shortest
Excitation Time 0.05S
Dimensions
Hong Kong (Headquarter) Flat 2108, 21F, CC WU Building 308, Hennessy Road Wan Chai - Hong Kong
Tel.: +852 3568 2257 Fax: +852 2125 4982
[email protected] General Enquiries [email protected] Sales Enquires [email protected] Certificates Wenzhou - Zhejiang - P.R. China
Gongye 2nd Road Yongjia, Wenzhou, Zhejiang, P.R. China Shijiazhuang - Hebei - P.R. China
308 National Road Ningjin, Xingtai, Hebei, P.R. China