access control fermax

86
ACCESS CONTROL

Upload: duthoaiquyen

Post on 10-Mar-2015

757 views

Category:

Documents


13 download

TRANSCRIPT

Page 1: Access Control FERMAX

ACCESS CONTROL

Page 2: Access Control FERMAX

WARRANTYAll Fermax products have a 24 months warranty.

Fermax«obligation under this warrany, however, isexpressly limited (at Fermax«option) to replacing,repairing, or issuing credit for any product returnedto FERMAX within twenty four (24) months from dateof shipment by FERMAX and then only if: (a) thedefective product is returned to FERMAX, transportcharges prepaid, (b) examination of the productdiscloses to FERMAX«satisfaction that defects in theproduct have not been caused by misuse, neglect,improper installation, repair alteration or accidentand (c ) re turned mater ia l must at tach theAuthorization for return form.

This warranty does not cover problems arising duecauses with equipment (for example deficiencies ininstallation or incorrect wiring), nor breakdownscaused by incorrect manipulat ion of blows.

LIMIT OF LIABILITYIt is expressly understood and agreed that FERMAXis not an insurer that the products or services soldhereunder will perform functions or prevent: thatFERMAX shall be exempt from liability for all loss ordamage therefrom; and that insurance, if any, shallbe obtained by the Distributor.

Liabil ity shall be l imited to an amount to theconsideration paid by the distributor for such productsor services as the distributor exclusive remedy.

DELIVERY15 days after order confirmation and reception ofpayment.Allow 30 days for special orders.Every endeavour will be made by the Company toadhere to the delivery dates quoted, but such datesare only estimate and are not guaranteed neither shallthey be a term of condition between the Buyer andthe Company.The Buyer shall be responsible for arranging insuranceon goods col lected by the i r own carr iers .Delay in delivery shall by no means entitle the Buyerto cancel the order or thereby render the Seller liableto the Buyer for any loss or expense arising from thede lay un less otherwise agreed in wr i t ing .Ex works. ˚

OWNIRSHIP OF GOODSThe goods shall remain the property of the Seller untilpaid for in full by the Buyer.

CANCELLATIONCancellation of any order or goods or any part of anorder will not be valid after the Buyer has placed theorder unlessthe cancellation is accepted by the Sellerin writing.

Page 3: Access Control FERMAX
Page 4: Access Control FERMAX
Page 5: Access Control FERMAX

Dear partner,

This fourth edition of the Access Control catalogue takes in the complete range of FERMAX solutions foraccess restriction.

You can choose the most suitable option according to the specific needs and features of the installation:

• Styling: for interiors, outdoors or vandal-proof version.• Reader technology: keypad, proximity, radio frequency, fingerprint and Bluetooth.• System: Stand-alone (1 access), stand-alone in network (32 accesses) and centralized (large installations).

This new document has been designed to provide you with detailed and structured information on all theoptions, in technical f i le format, for easy understanding and use by the professional.

The main new features that you will find in this edition are:

• Stand-alone system.

The Bluetooth Kit lets you open the door with a mobile phone. It is a technological and innovating product.City Fingerprint Reader. Cutting-edge technology now at a highly competitive price. Includes thermal readertechnology, recommended in exteriors. Storage capacity: 950 fingerprints.Marine Readers for exteriors made in stainless steel, now available in keypad version (Memokey) and proximity(Private).New RF remote control l ine with an exclusive design and more robust mechanics.

We emphasize the versatility offered by our access control range for integration in any video entry systempanel. Ask for the modular format of the desired reader and integrate it in an outdoor panel.

• Stand-alone system in network. Recommended for average size applications - up to 32 accesses and 1000users. Management handled from intuitive and practical PC software. An interesting balance between benefitsand simplicity in system management and start-up.

• Centralized system. The new software that comes as standard with the Central Unit also includes managementof user authorizations/cancellations and access permits/restrictions and now also time & attendance softwarefor staff clock-in management and calculation of hours worked (for pays management).

You can also find all updated information on our products in the product section of our website www.fermax.com.

Thank you for your confidence.

Jeremy PalacioAccess Control Product Manager

Page 6: Access Control FERMAX
Page 7: Access Control FERMAX

S t a n d - a l o n e 1 1

S t a n d - a l o n e i n n e two r k 3 7

C e n t r a l i z e d 4 9

A c c e s s o r i e s 7 5

C o n t e n t G u i d e

Page 8: Access Control FERMAX

Keypad

Proximity

Bruto

Description

Bruto ModuleCitymax Module

City Bruto Loft

3610

3600

4480

23291

ref.

4500

2 1 3 3

-

2553

ref.

4540

3623

45504550+4420

ref.

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

Description

Citymax Module Bruto Module Marine

Description

2347

2260

4490

23351or

4490+4420

ref.

4520

-

4510

2552or

4510+4420

ref.Description

4530

3624

4560

ref.

4560+4420

4698

-

-

-

ref.

Marine

QUICK GUIDE

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

06

City Loft

-

-

2263

2560

ref.

-

-

2288

2268

ref.

2520

-

-

2561

ref.

2523

-

-

22371

ref.

4699

-

-

-

ref.

Page 9: Access Control FERMAX

BluetoothTM

BluetoothTM

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

Description

PCB Module

7900

-

-

-

ref.

Key button

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

Description

City

or2315+4420

-

-

2315

23261

ref.

Bruto

-

-

-

2554

ref.

Bluetooth

City

Description

4477

4478

-

-

ref.

4476

-

-

-

ref.

Citymax Module

Fingerprint

Optical Reader

-

-

-4470+4420

ref.

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

Description

City

6989

-

69896989+4420

ref.

Citymax Module

QUICK GUIDE

STAND-ALONE

STAND-ALONE KIT

STAND-ALONE IN NETWORK

CENTRALIZED

07

Radio frequency

Box Receiver DIN Rail MDS Single Channel Receiver

MDS SecondaryReceiver

7960

7912

-

-

ref.

7903

7910

-

-

ref.

7952

7911

-

1065

ref.

-

-

-

2464

ref.

6990

6988

69906990+4420

ref.

Page 10: Access Control FERMAX

08

Accessories - Common to all the access control systems.

Stand-alone - The easiest access control to install. No PC required.An ideal access control solution for indoors and outdoors, to manage a single access or door in the most practical and

simple way. Swift and easy to install: only two power supply cables. Reader technologies available are keypad, proximity

readers, radio frequency systems, Bluetooth technology and digital fingerprint.

Stand-alone in network - Secure and practical access control. PC required.The stand-alone access control system in network is recommended when you want to manage permits/restrictions for

up to 32 accesses or doors from a PC. The on–line events record enables a fast graphic view of incoming and outgoing

user flow.

Centralized - The most complete and versatile solution. PC Required.Enables complete management of an installation with multiple accesses (up to 2048) and advanced access control

functions. There are two systems: MDS and CAC. MDS is recommended in installations with audio or video door entry

systems and access control functions, alarms and automation. CAC is the best option for purely access control

installations thanks to its new functions: vehicle control and time & attendance for salary management. Also includes

alarms management and automation.

Page 11: Access Control FERMAX

*(0)

Re f e rence char t / i n dex

09

CITY

CITYMAX MODULE

BRUTO

BRUTO MODULE

LOFT

MARINE

3610

2520

4500

2523

4540

4699

4480

-

-

-

4550

-

23291

2561

2553

22371

4550*(1)+4420

-

KEYPAD

PROXIMITY

CITY

CITYMAX MODULE

BRUTO

BRUTO MODULE

LOFT

MARINE

2347

2263

4520

2288

4530

4698

4490

-

4510

-

4560

-

23351 o 4490+4420

2560

2552 o 4510+4420

2268

4560+4420

-

KEY BUTTON

CITY

CITYMAX MODULE

BRUTO

BRUTO MODULE

-

-

-

-

2315

-

-

-

23261 o 2315+4420

-

2554

-

RADIOFREQUENCY

PCB MODULE RECEIVER

BOX RECEIVER

DIN RAIN MODEL RECEIVER

SINGLE CHANNEL RECEIVER

MDS SECUNDARY RECEIVER

7900

7960

7903

7952

-

-

-

-

-

-

-

-

-

1065

2464

BLUETOOTH

CITY

CITYMAX MODULE

4477

4476

-

-

-

-

FINGERPRINT

A

N

-

6990

6989

-

6990

6989

4470+4420

6990+4420

6989+4420

STAND-ALONE STAND-ALONEIN NETWORK

CENTRALIZED(MDS and CAC)

R E F E R E N C E SREADER

OPTICAL READER

CITY

NOTE: The symbol “-” indicates that there is no such combination. *(0) Ref.4480 is a keypad and proximity reader. *(1) Ref.4550 is a keypad

and proximity reader.

*(1)

CITYMAX MODULE

Page 12: Access Control FERMAX

Simple access control system managing one access.

Page 13: Access Control FERMAX

S t a n d - a l o n e a c c e s s c o n t r o l

Page 14: Access Control FERMAX

Memokeystand-alone

1 2 3

4 5 6

7 8 9

A 0 B

ST

AN

D-A

LO

NE

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):

12V (ac/dc) 6/602A (NA,NC)

0 to 70ºC

130x128x18115x114x45130x128x33

4307

Power supply (V):Consumption (mA) without door release:Relay Contact:

Operating temperature:Programmable from 01 to 99 sec. or bistable

Exit pushbutton and free access button input.

Electric lock activation by relay. With auxiliary relay for other

functions.

Programmable relay times (monostable, bistable).

Each code can activate one or two relays simultaneously.

Multi-function OC output: coercion alarm, wrong code or

tamper.

Technical features

Installation Keypad is located in the outside zone. The rest of the

devices, installed indoors, are connected to it: power supply

and electric lock. Optionally, an exit pushbutton can be

used if there is no door handle (LOFT model) to detect if

the door remains open.

Programming from the keypad by Master code.Programming

Access control keypad with capacity for up to100 different of 4 to 6-digit codes.Manufactured in aluminium.Flush or surface mounted ( ref .8851).Recommended for interiors and exteriors.Reader and controller in the same module(ref.3610) or separate (ref.3620 and ref.3621).

City Memokey (ref.3610)

12 Available in kit (ref.3600)

Power supply

Ref.3610

Door release

Exitbutton

2

2

230Vac

2

Page 15: Access Control FERMAX

13

Memokeystand-alone

1 2 3

4 5 6

7 8 9

A 0 B

ST

AN

D-A

LO

NE

Memokey City CR (ref.3620) Memokey controller CR (ref.3621)

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Metallic box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):

12V (ac/dc) 6/602A (NA,NC)

0 to 70ºC

130x128x18115x114x45130x128x33154x203x50

4307

Power supply (V):Consumption (mA) without door release:Relay contact:

Operating temperature:Programmable from 01 to 99 sec. or bistable

Technical features

Installation The CR keypad is located on the outside, connected to the

controller situated in the interior, the same as the rest of

the devices: power supply and electric lock. Optionally, an

exit pushbutton can be used (if there is no door handle)

and a second CR keypad on the inside.

Programming from keypad by Master code.Programming

Reader (ref.3620) and controller (ref.3621) in twostand-alone modules for enhanced security.The controller is installed indoors next to the powersupply and door release. Metallic box included with controller (measurements:154x203x50mm).A second CR keypad can be added on the inside.Maximum distance: 100 meters.

City Memokey CR (ref.3620+3621)

Available in kit (ref.3591)

Exitbutton

22

Power supply

2

230Vac

6

Exit pushbutton and free access button input.

Electric lock activation by relay. With auxiliary relay for other

fuctions.

Programmable relay times (monostable, bistable).

Each code can activate one or two relays simultaneously.

Multi-function OC output: coercion alarm, wrong code or

tamper.

Electric lock unblocking by code (free access).

2

Door release

Ref.3620

Ref.3621

Page 16: Access Control FERMAX

Memokeystand-alone

Exitbutton

2

1 2 3

4 5 6

7 8 9

A 0 B

Power supply

Ref.2520

Door release

2

230Vac

2

ST

AN

D-A

LO

NE

City Memokey Module (ref.2520)

Access control keypad with capacity for up to 100different 4 to 6-digit codes.Manufactured in aluminium.To be fitted in CityMax audio or video door entrysystem outdoor panels to improve home security.Reader and controller integrated in the samemodule (ref.2520).

Specifications Environmental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programmable from 01 to 99 sec. or bistableOperating temperature:

4307

12V (ac/dc)6/60

2A (NA,NC)

0 to 70ºC

Installation Audio or video door entry panel located in the outside

area. It is possible to set up the panel intuitively to

include a keypad (ref.2520) for greater security and more

convenient access.

Programming from keypad by Master code.Programming

14

Technical features Exit pushbutton and free access button input.

Electric lock activation by relay. With auxiliary relay for

other functions.

Programmable relay times (monostable, bistable).

Each code can activate one or two relays simultaneously.

Open collector auxiliary output (150mA max) to indicate

sabotage attempt or door open/forced.

Electric lock unblocking by code (free access).

Page 17: Access Control FERMAX

15

Memokeystand-alone

1 2 3 A

654 0

B987

Power supply

Ref.4500

Door release

Exitbutton

2

2

230Vac

2

Exit pushbutton and free access button input.

Electric lock activation by relay. With auxiliary relay for other

functions.

Programmable relay times (monostable, bistable).

Each code can activate one or two relays simultaneously.

Multi-function OC output: coercion alarm, wrong code or

tamper.

Technical features

ST

AN

D-A

LO

NE

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box(WxHxDmm):Environmental protection (IP):Protection against knocks (IK):

12V (ac/dc) 6/602A (NA,NC)

0 to 70ºC

135x130x18115x100x45135x131x42

5309

Power supply (V):Consumption (mA) without door release:Relay contact:

Operating temperature: Programmable from 01 to 99 sec. or bistable

Installation Keypad is located in the outside zone. The rest of the devices,

installed indoors, are connected to it: power supply and

electric lock. Optionally, an exit pushbutton can be used if

there is no door handle (LOFT model) to detect if the door

remains open.

Programming from keypad by Master code.Programmation

Access control keypad with capacity for up to 100different 4 a 6-digit codes.Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Reader and controller integrated in the same module.Ideal for troubled zones or districts, offices, banks,etc.

Bruto Memokey (ref.4500)

Available in kit (ref.2133)

Page 18: Access Control FERMAX

Memokeystand-alone

Exit pushbutton and free access button input.

Electric lock activation by relay. With auxiliary relay for

other functions.

Programmable relay times (monostable, bistable).

Each code can activate one or two relays simultaneously.

Multi-function OC output: coercion alarm, wrong code or

tamper.

Technical features

ST

AN

D-A

LO

NE

Programming from keypad by Master code.

Access control keypad with capacity for up to 100different 4- to 6-digit codes.Vandal-proof keypad.To be fitted in Bruto audio or video door entry panelviewers for enhanced security in the home.Reader and controller integrated in the same module(ref.2523).

Bruto Memokey Module (ref.2523)

Specifications Environmental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programable from 01 to 99 sec. or bistableOperating temperature:

5309

12V (ac/dc)6/60

2A (NA,NC)

0 to 70ºC

16

Exitbutton

2

Power supply

Ref.2523Door release

2

230Vac

2

Keypad is located in the outside zone. The rest of the

devices, installed indoors, are connected to it: power

supply and electric lock. Optionally, an exit pushbutton

can be used if there is no door handle (LOFT model) to

detect if the door remains open.

Installation

Programmation

Page 19: Access Control FERMAX

Power supply

Ref.4540

Door release

Exitbutton

2

2

230Vac

2

2

1 2 3

4 5 6

7 8 9

A 0 B

Availalble in kit (ref.3623) 17

Memokeystand-alone

Exit pushbutton and free access button input.

Electric lock activation by relay.

Multi-function OC output: coercion alarm, wrong code and

forced door.

Electric lock unblocking by code (free access).

Status LEDs: door open/closed/power supply.

Technical features

ST

AN

D-A

LO

NE

Specifications Dimensions (WxHxDmm):Flush box:Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):

12V (ac/dc) 20/70 2A (NA,NC) 0 to 70ºC

60x130x23 Not required Not required

6606

Power supply (V):Consumption (mA) without door release:Relay contact:Operating temperature:

Keypad is located in the outside zone. The rest of the devices,installed indoors, are connected to it: power supply andelectric lock. Optionally, an exit pushbutton can be used ifthere is no door handle (LOFT model) to detect if the doorremains open.

Programming from keypad by Master code.

Access control keypad with capacity for up to 100different 4 to 6-digit codes.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Reader and controller integrated in the same moduleIdeal for screen profiles in offices.Includes a 50cm cable.

Loft Memokey (ref.4540)

Installation

Programmation

Page 20: Access Control FERMAX

Power supply

Ref.4699

Door release

Exitbutton

2

2

230Vac

2 1 2 3

A

654

0 B

987

Memokeystand-alone

Exit pushbutton and free access button input.

Electric lock activation by relay. With auxiliary relay for

other functions.

Programmable relay times (monostable, bistable).

Each code can activate one or two relays simultaneously.

Multi-function OC output: coercion alarm, wrong code

or tamper.

Technical features

ST

AN

D-A

LO

NE

Specifications

Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: powersupply and electric lock. Optionally, an exit pushbuttoncan be used if there is no door handle (LOFT model) todetect if the door remains open.

Programming from keypad by Master code.

Marine Memokey (ref.4699)

18

Access control keypad with capacity for up to 100different 4- to 6-digit codes.Stainless steel panel 2.5mm thickness.Keypad with 4x3 layout and orange backlight.Flush or surface mounted (ref.4645).Recommended for interiors and exteriors.Reader and controller integrated in the samemodule.

Installation

Programmation

Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):

12V (ac/dc) 6/602A (NA,NC).

0 to 60ºC

153x123x50130x160x55154x184x73

5309

Power supply (V):Consumption (mA) without door release:Relay contact:

Operating temperature:Programmable from 01 to 99 sec. or bistable

Page 21: Access Control FERMAX

Privatestand-alone

19Available in kit (ref.2260)

( restricted area )

PRIVATE ACCESS CONTROL

Technical features

ST

AN

D-A

LO

NE

Specifications

Exit pushbutton and free access button input.

Electric lock activation by relay with programmable timing.

Programming help LEDs.

Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect if thedoor remains open.

City Private (ref.2347)Proximity card reader with capacity for up to 400users.Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Reader and controller integrated in the same module.

Can be done in 3 ways:

Master card: The first time that the power supply

is connected, the system waits for a proximity card

which will be considered as “master card”.

Keypad: Recommended if we want to cancel lost

cards (ref. 2306).

PC software: The most convenient solution for

authorization and cancellation management (ref.2351).

Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and

with magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Withoutpersonalizing

or magnetic strip.

Proximitykeyring.

Installation

Programmation

Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:

2A (NA,NC).

0 to 60ºC

6/5 cmRS-232

130x128x18115x114x45130x128x33

4307

12V (ac/dc) 80/120

Relay contact:

Operating temperature:Reading distance(card/keyring):IP Interface:

Programmable from 01 to 99 sec. or bistable

Power supply

Ref.2347

Door release

Exitbutton

2

2

230Vac

2

2

Page 22: Access Control FERMAX

Privatestand-alone

( restricted area )

PRIVATE ACCESS CONTROL

Power supply

Ref.2263Door release

Exitbutton

2

230Vac

2

2

2

Technical features

ST

AN

D-A

LO

NE

Proximity card reader with capacity for up to 400users.To be fitted in the viewer of CityMax audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.

City Private Module (ref.2263)

Exit pushbutton and free access button input.

Electric lock activation by relay with programmable timing.

Programming help LEDs.

The audio or video door entry panel is located in the outside

area. It is possible to set up the panel intuitively to include

a keypad (ref.2263) for greater security and more convenient

access.

Environmental protection(IP):Protection against knocks (IK):Power supply (V):Cons. (mA) withot door release:Relay contact:

0 to 60ºC

6/5 cmRS-232

4307

12V (ac/dc)80/120

2A (NA,NC).

Operating temperature:Reading distance(card/lkeyring):PC Interface:

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and

with magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Withoutpersonalizing

or magnetic strip.

Proximitykeyring.

20

Specifications

Identifiers

Installation

Programmation Can be done in 3 ways:

Master card: The first time that the power supply

is connected, the system waits for a proximity card

which will be considered as “master card”.

Keypad: Recommended if we want to cancel lost

cards (ref. 2306).

PC software: The most convenient solution for

authorization and cancellation management (ref.2351).

Page 23: Access Control FERMAX

21

Privatestand-alone

2

( restricted area )

PRIVATE ACCESS CONTROL

Power supply

Ref.4520

Door release

Exitbutton

2

230Vac

2

2

Technical features

ST

AN

D-A

LO

NE

Proximity card reader with capacity for up to 400users.Vandal-proof reader.To be fitted in the viewer of the Bruto audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.

Private Bruto (ref.4520)

Exit pushbutton and free access button input.

Electric lock activation by relay with programmable timing.

Programming help LEDs.

Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect ifthe door remains open.

Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):Comsumption (mA) door release

2A (NA,NC).

0 to 60ºC

4/2 cmRS-232

135x130x18115x100x45135x131x42

5309

12V (ac/dc)80/120

Relay contact

Operating temperatureReading distance:(card/keyring):PC Interface:

Programmable from 01 to 99 sec. or bistable

Can be done in 3 ways:

Master card: The first time that the power supply

is connected, the system waits for a proximity card

which will be considered as “master card”.

Keypad: Recommended if we want to cancel lost

cards (ref. 2306).

PC software: The most convenient solution for

authorization and cancellation management (ref.2351).

Specifications

Identifiers

Installation

Programmation

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and

with magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Withoutpersonalizing

or magnetic strip.

Proximitykeyring.

Page 24: Access Control FERMAX

Privatestand-alone

Technical features

ST

AN

D-A

LO

NE

Proximity card reader with capacity for up to 400users.Vandal-proof reader.To be fitted in the viewer of the Bruto audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.

Bruto Private Module (ref.2288)

Can be done in 3 ways:

Master card: The first time that the power supply

is connected, the system waits for a proximity card

which wil l be considered as master card.

Keypad: Recommended if we want to cancel lost

cards.

PC software: The most convenient solution for

authorization and cancellation management (ref.2351).

Environmental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programmable from 01 to 99 sec. or bistableOperating temperature:

5309

12V (ac/dc)80/120

2A (NA,NC)

0 to 70ºC

Exit pushbutton and free access button input.

Electric lock activation by relay with programmable timing.

Programming help LEDs.

22

Keypad is located in the outside zone. The rest of the devices,installed indoors, are connected to it: power supply andelectric lock. Optionally, an exit pushbutton can be used ifthere is no door handle (LOFT model) to detect if the doorremains open.

2

Exitbutton

( restricted area )

PRIVATE ACCESS CONTROL

Specifications

Identifications

Installation

Programmation

ref.23361 ref.2336 ref.2363 ref.2364 ref.44501

Withoutpersonalizing and

with magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Withoutpersonalizing

or magnetic strip.

Proximitykeyring.

Power supply

Ref.2288

Door release

2

230Vac

2

2

Page 25: Access Control FERMAX

Available in kit (ref.3624) 23

Privatestand-alone

Loft Private (ref.4530)Access control keypad with capacity for up to 100different 4 to 6-digit codes.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Reader and controller integrated in the same moduleIdeal for screen profiles in offices.Includes a 50cm cable .

Technical features

ST

AN

D-A

LO

NE

Exit pushbutton and free access button input.

Electric lock activation by relay with programmable timing.

Programming help LEDs.

Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect ifthe door remains open.

Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):

45/752A (NA,NC).

0 to 60ºC

8/6 cmRS-485

60x130x23Not requiredNot required

6606

12V (ac/dc)

Cons. (mA) without door release:Relay contact:Operating temperature:Reading distance(card/keyring):PC Interface:

2

Specifications

Identifiers

Installation

Programmation Can be done in 3 ways:

Master card: The first time that the power supply

is connected, the system waits for a proximity card

which will be considered as master card.

Keypad: Recommended if we want to cancel lost

cards (ref. 2306).

PC software: The most convenient solution for

authorization and cancellation management (ref.3625)

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and

with magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Withoutpersonalizing

or magnetic strip.

Proximitykeyring.

Power supply

Ref.4530

Door release

Exitbutton

2

230Vac

2

2

Page 26: Access Control FERMAX

Privatestand-alone

2

Exitbutton

( restricted area )

PRIVATE ACCESS CONTROL

Power supply

Ref.4698

Door release

2

230Vac

2

2

Technical features

ST

AN

D-A

LO

NE

Proximity card reader with capacity for up to 400users.Stainless steel panel 2.5mm thickness.Flush or surface mounted (ref.4645).Recommended for interiors and exteriors.Reader and controller integrated in the same module.

Marine Private (ref.4698)

Keypad is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock. Optionally, an exit pushbutton can beused if there is no door handle (LOFT model) to detect ifthe door remains open.

Exit pushbutton and free access button input.

Electric lock activation by relay with programmable timing.

Programming help LEDs.

24

Specifications

Identifiers

Installation

Programmation

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and

with magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Withoutpersonalizing

or magnetic strip.

Proximitykeyring.

Can be done in 3 ways:

Master card: The first time that the power supply

is connected, the system waits for a proximity card.

which will be considered as master card.

Keypad: Recommended if we want to cancel lost

cards (ref.1306).

PC software: The most convenient solution for

authorization and cancellation management (ref.2351)

Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):

80/1202A (NA,NC).

0 to 60ºC

6/5 cmRS-232

153x123x50130x160x55154x184x73

5309

12V (ac/dc)

Cons. (mA) without door release:Relay contact:Operating temperature:Reading distance(card/keyring):PC Interface:

Page 27: Access Control FERMAX

Radiofrequencystand-alone

Trinary RF emitter (ref.79561)

Radiofrequency emitter 433.92MHz.Trinary technology.New and highly robust design.Dual channel emitter that can activate two relays.Configuration of the sequence of digits required bymeans of microswitches.Simple and easy to use.

Available in kit (ref.7910 y ref.7911) 25

Installation

RF EmitterRef.79561

Door release

Receiver

2

ST

AN

D-A

LO

NE

Dip switch configuration (8 microswitches in 3 positions).

Unlimited number of users admitted by the receiver.

Includes battery 12Vdc.

Range: 30m.

Frequency: 433.92 MHz.

Consumption in transmission: 10mA

Consumption in standby: 0.1mA

Technical features

Compatible with ref.7952 Single channel receiver for garages.

ref.7900 Single channel receiver PCB (OEM).

ref.7903 Single channel receiver DIN rail.

Specifications Dimensions (WxHxDmm): 53x36x13mm

Page 28: Access Control FERMAX

2

2RF emitterRef.79561

Door release

Ref.7952

Alarm

Ref.7934

Compatible with Trinary emitter (ref.79561)

Radiofrequencystand-alone

Single channel receiver 433.92MHz.Trinary technology.When the code emitted by the trinary emitter(ref.79561) is received, the receiver closes a circuitthat triggers the electric lock or door automation.Mounted in watertight box (IP65) in ABS.Programming by 8 microswitches in 3 positions.

Receiver for garages (ref.7952)

ST

AN

D-A

LO

NE

Includes rigid antenna 25 cm.

Optionally, by adding card ref.7934, the receiver can be

turned into dual channel to trigger a second relay.

Reception frequency: 433.92 MHz.

Sensitivity: 3 mV

Relay contact: 2 A max.

Power supply: 220Vac/50Hz

Consumption: 110 mA in standby.

Installation

Specifications Dimensions (WxHxDmm): 90x165x55mm

26 Available in kit (ref.7911)

Technical features

Page 29: Access Control FERMAX

Radiofrequencystand-alone

Trinary dip switch configuration (8 microswitches in 3 positions).

Power supply: 12 Vdc/12 Vac.

Frequency: 433.92 MHz.

Output 12Vac to activate an electric lock.

Output for pushbutton connection to open the door from

inside.

Single channel receiver 433.92MHz.Trinary technology.The receiver admits all emitters (ref.79561)programmed with the same code.Can be installed in any FERMAX audio or video doorentry panel.

Single Channel Receiver (ref.7900)

Compatible with Trinary emitter (ref.79561)

27

Exitbutton

2

RF emitter(ref.79561)

Power supply

Ref.7900(To be installed inside theflush box).

Door release

2

230Vac

2

ST

AN

D-A

LO

NE

Installation

Technical features

Specifications Dimensions (WxHxDmm): 20x70x60mm

Page 30: Access Control FERMAX

Radiofrequencystand-alone

Single channel receiver 433.92MHz.Trinary technology.The receiver admits all emitters (ref.79561)programmed with the same code.Includes, in DIN6 format, the RF receiver andtransformer or power supply.Ideal for shops, offices and businesses.

DIN rail receiver (ref.7903)

Compatible with Trinary emitters (ref.79561)

Electric cabinet

Ref. 7903REF.7903

ST

AN

D-A

LO

NE

Installation

Direct connection to 220Vac/50Hz.

DIN rail or wall mounted.

Output for pushbutton connection to open door from

inside.

Frequency: 433.92 MHz.

Trinary dip switch configuration (8 microswitches in 3

positions).

Output 12Vac for an electric lock activation.

Dimensions: 6-element DIN.

28 Available in kit (ref.7910)

Technical features

RF emitterRef. 79561

Specifications Dimensions (WxHxDmm): 105x90x60mm

Page 31: Access Control FERMAX

29Available in kit (ref.7912)

Radiofrequencystand-alone

Unique and exclusive code per emitter.

Includes battery 12Vdc.

Range: 30m.

Frequency: 433.92 MHz.

Consumption in transmission: 10 mA.

Consumption in standby: 0.1mA

Radiofrequency emitter 433.92MHz.Digital Technology.New and highly robust design.Dual channel emitter that can activate two relays.Secure code, unique, non configurable and exclusiveas standard per emitter.It is necessary to authorize/cancel emitters in thereceivers.

RF digital emitter (ref.24651)

ST

AN

D-A

LO

NE

Installation

Compatible with Ref.7960 Villa receiver (stand-alone).

Ref.1065 MDS receiver (centralized).

Ref.2464 MDS Secondary receiver (centralized).

Technical features

2RECEPTOR SEGURIDADSECURITY RECEIVERREF. 24561

RF emitterRef. 24651

Door release

RF receiverRef.7960

Specifications Dimensions (WxHxDmm): 53x36x13mm

Page 32: Access Control FERMAX

Radiofrequencystand-alone

Radiofrequency receiver 433.92MHz.Digital technology.Only authorized digital (ref.24651) or dual (ref.25511)emitters will trigger the device.Reduced size enables installation in electricalcabinets (embeddable in standard boxes 10x10cm).Emitters must be authorized in the receiver.

Villa Receiver (ref.7960)

Compatible with Digital (ref.24651) or dual (ref.25511) emitters.

ST

AN

D-A

LO

NE

Specifications Dimensions (WxHxDmm): 62x70x20mm

30 Available in kit (ref.7912)

Power supply 12Vac/12Vdc.

Lets you store up to 10 emitters (users) in memory with

unique and different codes.

Electric lock activation by relay. Programmable timing.

Exit pushbutton input.

Frequency: 433.92 MHz.

Door open time programming by dip-switch.

Technical features

Installation2

RECEPTOR SEGURIDADSECURITY RECEIVERREF. 7960

RF emitterRef. 24651

Door release

ReceiverRef.7960

Page 33: Access Control FERMAX

Radiofrequencystand-alone

In addition to the RF functions, incorporates proximity

card electronics for use in any proximity reader.

Includes battery 12Vdc.

Range: 30m.

Proximity reader distance: 2 cm.

Frequency: 433.92 MHz.

Consumption in transmission: 10mA.

Consumption in standby: 0.1mA

31

Radiofrequency emitter 433.92MHz.Dual technology.New and highly robust design.Dual channel emitter can activate two relays.Secure code, unique, non configurable and exclusiveas standard per emitter.It is necessary to authorize/cancel emitters in thereceivers.Internally integrates proximity card electronics so canbe used as a dual channel emitter and as substituteidenti f ier for proximity cards or keyrings.

Dual RF emitter (ref.25511)

Installation

RF emitterRef.25511

Door release

Receiver for garages

2

ST

AN

D-A

LO

NE

Specifications Dimensions (WxHxDmm): 53x36x13mm

Compatible with Ref.7960 Villa receiver (stand-alone).

Ref.1065 MDS receiver (centralized).

Ref.2464 MDS secundary receiver (centralized).

Technical features

Page 34: Access Control FERMAX

Power supply

Ref.4477

Door release

Exitbutton

2

2

230Vac

2

BluetoothTM

Bluetoothstand-alone

Access control reader by Bluetooth technology wherethe mobile telephone acts as user identifier.Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Reader and controller in the same module.

ST

AN

D-A

LO

NE

Electric lock activation by relay.

Programmable relay time (monostable, bistable).

Several operating modes: authorized personnel only (capacity

40 users) or without user limits.

In “authorized personnel only” mode the door can be opened

totally hands free, with key confirmation or PIN code. In “no

user limit” mode the door is always opened by a PIN.

Configurable reader range: up to 2m, 9m or 20m.

Programmation Programming can be done in three ways: through a master

mobile (recognized by the reader when powered up the first

time) with simple and intuitive commands, by PC with Bluetooth

connection (software downloadable from www.fermax.com)

or by PDA with Bluetooth.

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Enviromental protection (IP):Protection against knocks (IK):

12V (ac/dc) 80/200 2A (NA,NC)

0 to 70ºC

130x128x18115x114x45130x128x33

4307

Power supply (V):Cons. (mA) without door release:Relay contact:

Operating temperatue:Programmable from 01 to 99 sec. or bistable

City Bluetooth (ref.4477)

32 Available in kit (ref.4478)

Installation The reader is located in the outside zone. The rest of thedevices, installed indoors, are connected to it: power supplyand electric lock.

Technical features

BluetoothTM

Page 35: Access Control FERMAX

BluetoothTM

Power supply

Ref.4476

Door release

Exitbutton

2

2

230Vac

2

2

BluetoothTM

CityMax Bluetooth (ref.4476)

Access control reader by Bluetooth technology where

the mobile telephone acts as user identifier.

To be fitted in the viewer of CityMax audio or video

door entry panels for enhanced security in the home.

Reader and controller in the same module.

33

Bluetoothstand-alone

ST

AN

D-A

LO

NE

Specifications

The audio or video door entry panel is located in the outsidearea. It is possible to set up the panel intuitively to includea reader (ref.4476) for greater security and more convenientaccess.

Electric lock activation by relay.

Programmable relay time (monostable, bistable).

Several operating modes: authorized personnel only (capacity

40 users) or without user limits.

In “authorized personnel only” mode the door can be opened

totally hands free, with key confirmation or PIN code. In “no

user limit” mode the door is always opened by a PIN.

Configurable reader range: up to 2m, 9m or 20m.

Programmation Programming can be done in three ways: through a master

mobile (recognized by the reader when powered up the first

time) with simple and intuitive commands, by PC with Bluetooth

connection (software downloadable from www.fermax.com)

or by PDA with Bluetooth.

Enviromental protection (IP):Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Relay contact:Programmable from 01 to 99 sec. or bistableOperating temperature:

4307

12V (ac/dc)6/60

2A (NA,NC)

0 to 70ºC

Installation

Technical features

Page 36: Access Control FERMAX

Fingerprintstand-alone

City fingerprint (ref.6990)

Fingerprint reader with thermal sensor and storagecapacity for 950 prints.Manufactured in aluminium in new City styling.Flush or surface mounted.Recommended for interiors and exteriors.Reader and controller integrated in the samemodule.

ST

AN

D-A

LO

NE

34 Available in kit (ref.6988)

Programmation The system is programmed with one fingerprint (the

administrator’s) and with a remote infrared keypad for

user authorizations/cancellations.

Installation The reader is located in the outside zone. The rest of

the devices, installed indoors, are connected to it: power

supply and electric lock. Optionally, an exit pushbutton

can be used if there is no door handle (LOFT model) to

detect if the door remains open.

Exit pushbutton and free access button input.

Number of users:

- 950 in 1 fingerprint per person mode.

- 630 in 2 fingerprints per person mode.

2 status signal LEDs: door open/closed.

Display 7-3-digit segments.

Infrared receiver for programming.

Electric lock activation by relay and one auxiliary relay.

Programmable relay times (monostable, bistable).

Specifications Dimensions (WxHxDmm):Flush box (included):Superface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):

12V (ac/dc) 6/602A (NA,NC) 0 to 60ºC

130x128x18115x114x45130x128x33

4307

Power supply (V):Consumtion (mA) without door release:Relay contact:Operating temperature:

Power supply

Ref.6990

Door release

Exitbutton

2

2

230Vac

2

2

Technical features

Page 37: Access Control FERMAX

35

City fingerprint module (ref.6989)

Fingerprint reader with thermal sensor and storagecapacity for 950 prints.To be fitted in the viewer of CityMax audio or videodoor entry panels for enhanced security in the home.Reader and controller integrated in the same module.

Fingerprintstand-alone

ST

AN

D-A

LO

NE

Programmation The system is programmed with one fingerprint (the

administrator) and with a remote infrared keypad for user

authorizations/cancellations.

The audio or video door entry panel is located in the

outside area. It is possible to set up the panel intuitively

to include a reader (ref. 6989) for greater security and

more convenient access.

Installation

Exit pushbutton and free access button input.

Number of users:

- 950 in 1 fingerprint per person mode.

- 630 in 2 fingerprint per person mode.

2 status signal LEDs: door open/closed.

Display 7 3-digit segments.

Infrared receiver for programming.

Electric lock activation by relay and one auxiliary relay.

Programmable relay times (monostable, bistable).

Specifications Environmental protection (IP):Protection against knocks (IK):Power supply (V):

6/602A (NA,NC) 0 to 60ºC

43 07

12V (ac/dc)

Consumption (mA) without door release:Relay contact:Operating temperature:

Exitbutton

2

Technical features

Power supply

Ref.6989

Door release

2

230Vac

2

Page 38: Access Control FERMAX

Access control systems consisting of several accesses (up to a maximum of 32) and PC managed.

Page 39: Access Control FERMAX

S t a n d - a l o n e a c c e s s c o n t r o l i n n e t w o r k

Page 40: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

K

38

Installation Installation in mechanism box 100x100mm or surface

mounted with 2 screws (included).

Programmed from a PC with the corresponding software

(included in ref.44201).Programmation

Each door controller manages 1.000 users.

The connection between controllers consists of 2 power

wires and a twisted pair for data.

Admits an exit and entrance reader, electric lock relay,

auxiliary relay for other functions, pushbutton connection,

door sensor and free access button.

Necessary for vehicle accesses for connection of entrance

or exit detection coils.

Status LEDs: transmission and reception.

Lets you connect any reader with Wiegand-26 output or

Magstrip (Aba TrackII or Dataclock).

Admits Dallas i-button key readers and matrix keypads in

8-bit burst format.

One power supply (ref.4813) recommended every 6 readers.

Technical features

Specifications Dimensions (WxHxDmm): 85x88x25Power supply (V): 12Vdc

Consumption (mA): 15/100Operating temperature: 0 to 60ºC

Door controller with 500 event memory (ref.44201).Includes CD with management software.The door controller manages the devices in each access: upto two readers (if they are used as entrance and exit), electriclock, door sensor and exit button.Up to 32 door controllers can be connected in series tomanage 32 entry and exit accesses.Thanks to the internal memory, it enables userauthorizations/cancellations and access permits/restrictionsfrom a PC.On-line incidents record. Capacity: 1.000 users.Indoor installation and separate from the reader for greatersecurity.Admits Wiegand-26 input or magstrip.

Door Controller (ref.44201)

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

Up to

32

Read

ers

Controllerstand-alone in network

PC connection accessory(needed) ref.24661

PC

2 wires

power supply

Door controllers (ref.44201)

Page 41: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

K

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

Up to

32

Read

ers

PC connection accessory(needed) ref.24661

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

PC

2 wires

Power supply

Door controllers (ref.44201)

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0712Vdc30mA

0 to 60ºC

130x175x18115x162x45130x175x33

43

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

Installation The reader is located outdoors and connected to the controller

located in the interior. Optionally, an exit pushbutton can be

used (if there is no door handle).

Can be combined with any Wiegand-26 bit or Dataclock

output reader.

Programming and start-up from PC software (included in

ref.44201).Programmation

City Memokey&Private WG combination (ref.4480)

Access control reader with dual technology: proximity and keypadwith capacity for up to 1.000 users.Stand-alone or joint operation for greater security: PIN code +card.Manufactured in aluminium in City styling.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.

Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

39

Memokey&Private WGstand-alone in network

Technical features Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers equip the installation with access

control with anti-sabotage security, as neither the door opening

mechanism nor the exit button connection are built-in. These

functions are supported by the door controller with memory

(ref.44201).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: door open/closed/power supply.

Page 42: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

K

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

1 2 3

4 5 6

7 8 9

A 0 B

PC connection accessory(needed) ref.24661

PC

2 wires

Power supply

Door controllers (ref.44201)

40

Programming and start-up from PC software (included in

ref.44201).

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Loft Memokey&Private WG (ref.4550)Access control reader with dual technology: proximity and keypadwith capacity for up to 1.000 users.Stand-alone or joint operation for greater security: PIN code +card.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Ideal for screen profiles in offices.Includes a 50cm cable.Door controller (ref.44201) required for operation.

The reader is located outdoors and connected to the controller

located in the interior. Optionally, an exit pushbutton can be

used (if there is no door handle).

Can be combined with any Wiegand-26 bit or Dataclock output

reader.

Up to

32

Read

ers

Specifications

Installation

Programmation

Identifiers

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

Memokey&Private WGstand-alone in network

Dimensions (WxHxDmm):Flush box (Not required):Surface box (Not required):Environmental protection (IP):

0612Vdc40mA

0 to 60ºC

60x130x23

66

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers equip the installation with access control

with anti-sabotage security, as neither the door opening

mechanism nor the exit button connection are built-in. These

functions are supported by the door controller with memory

(ref.44201).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: door open/closed/power supply.

Technical features

Page 43: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

K

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair ( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

1 2 3

4 5 6

7 8 9

A 0 B PC connection accessory(needed) ref.24661

PC

2 wires

Power supply

Door controllers (ref.44201)

City Private WG (ref.4490)

Proximity card reader with capacity for up to 1.000users.Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Programming and start-up from PC software (included in

ref.44201).

The reader is located outdoors and connected to the controller

located in the interior. Can be combined with any Wiegand-

26 bit or Dataclock output reader.

Up to

32

Read

ers

Specifications

Installation

Programmation

Identifiers

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

41

Private WGstand-alone in network

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):

30mA0 to 60ºC

6/5 cmRS-485/USB

130x128x18115x114x45130x128x33

4307

12Vdc

Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers equip the installation with access

control with anti-sabotage security, as neither the door opening

mechanism nor the exit button connection are built-in. These

functions are supported by the door controller with memory

(ref.44201).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: door open/closed/power supply.

Technical features

Page 44: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

K

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

Up to

32

Read

ers

1 2 3

4 5 6

7 8 9

A 0 B PC connection accessory(needed) ref.24661

2 wires

PC

Power supply

Door controllers (ref.44201)

42

Bruto Private WG (ref.4510)

Proximity card reader with capacity for up to 1.000users.Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Programming and start-up from PC software (included in

ref.44201).

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxPmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):

300 to 60ºC

4/2 cmRS-485/USB

135x130x18115x100x45135x131x42

5309

12Vdc

Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:

The reader is located outdoors and connected to the controller

located in the interior. Optionally, an exit pushbutton can be

used (if there is no door handle).

Can be combined with any Wiegand-26 bit or Dataclock output

reader.

Specifications

Installation

Programmation

Identifiers

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

Private WGstand-alone in network

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers equip the installation with access control

with anti-sabotage security, as neither the door opening

mechanism nor the exit button connection are built-in. These

functions are supported by the door controller with memory

(ref.44201).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: door open/closed/power supply.

Technical features

Page 45: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

K

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

Up to

32

Read

ers PC connection accessory

(needed) ref.24661

PC

2 wires

Power supply

Door controller (ref.44201)

Loft Private WG (ref.4560)

Proximity card reader with capacity for up to 1.000users.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Ideal for screen profiles in offices.Includes a 50cm cable.Door controller (ref.44201) required for operation.

Programming and start-up from PC software (included in

ref.44201).

The reader is located outdoors and connected to the controller

located in the interior. Optionally, an exit pushbutton can be

used (if there is no door handle).

Can be combined with any Wiegand-26 bit or Dataclock output

reader.

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):

400 to 60ºC

6/5 cmRS-485/USB

60x130x23Not requiredNot required

6606

12V (ac/dc)

Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:

Specifications

Installation

Programmation

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501Identifiers

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

43

Private WGstand-alone in network

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers equip the installation with access control

with anti-sabotage security, as neither the door opening

mechanism nor the exit button connection are built-in. These

functions are supported by the door controller with memory

(ref.44201).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: door open/closed/power supply.

Technical features

Page 46: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

K

The reader is located outdoors and connected to the controller

located in the interior.

Can be combined with any Wiegand-26 bit or Dataclock

output reader.

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0712Vdc

300 to 60ºC

130x128x18115x114x45130x128x33

43

Protection against knocks (IK):Power supply (V):Consumption (mA) without door release:Operating temperature:Specifications

Installation

Programmation

44

Fingerprint WG

City WG fingerprint (ref.6990)

Fingerprint reader with thermal sensor and storagecapacity for 1.000 prints.Manufactured in aluminium in new City styling.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.44201) required for operation.

stand-alone in network

City fingerprint WG (ref.6990)

Door controller (ref.44201) required for operation.

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers equip the installation with access

control with anti-sabotage security, as neither the door opening

mechanism nor the exit button connection are built-in. These

functions are supported by door controller with memory

(ref.44201).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: door open/closed/power supply.

Display 7 3-digit segments.

Infrared receiver for programming.

Number of users:

- 950 in 1 person mode.

- 630 in 2 fingerprint mode.

The system is programmed with one fingerprint (the

administrator’s) and with a remote infrared keypad for user

authorizations/cancellations.

User authorizations and cancellations can be done from a PC

with the software included in the door controller (ref.44201).

Technical features

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

Up to

32

Read

ers PC connection accessory

(needed) ref.24661

PCconnectionaccessory(needed)ref.24661

PC

2 wires

Power supply

Door controller (ref.44201)

Page 47: Access Control FERMAX

ST

AN

D-A

LO

NE

IN

NE

TW

OR

KThe reader is located outdoors and connected to the controller

located in the interior. Optionally, an exit pushbutton can be

used (if there is no door handle).

Can be combined with any Wiegand-26 bit or Dataclock

output reader.

Environmental protection (IP):Protection against knocks (IK):Power supply (V):

300 to 60ºC

4307

12Vdc

Consumption (mA) without door release:Operating temperature:

45

Specifications

Installation

Programmation

City WG Module Fingerprint (ref.6989)

Fingerprint reader with thermal sensor and storage capacityfor 1.000 prints.To be fitted in the spare space of CityMax audio or videodoor entry panels for enhanced security in the home.Door controller (ref.44201) required for operation.

Fingerprint WGstand-alone in network

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers equip the installation with access

control with anti-sabotage security, as neither the door opening

mechanism nor the exit button connection are built-in. These

functions are supported by the door controller with memory

(ref.44201).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: door open/closed/power supply.

Display 7 3-digit segments.

Infrared receiver for programming.

Number of users:

- 950 in 1 person mode.

- 630 in 2 fingerprint mode.

The system is programmed with one fingerprint (the

administrator’s) and with a remote infrared keypad for user

authorizations/cancellations.

User authorizations and cancellations can be done from a PC

with the software included in the door controller (ref.44201).

Technical features

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

2 wires

twisted pair

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Readers

Up to

32

Read

ers

PC conectionaccessory (needed)

ref.24661

PCconnectionaccessory(needed)ref.24661

PC

2 wires

Power supply

Door controllers (ref.44201)

Page 48: Access Control FERMAX

Systems that let you approach complex installations with advanced functions and a multitude of accesses.

Page 49: Access Control FERMAX

C e n t r a l i z e d A c c e s s C o n t r o l

Page 50: Access Control FERMAX

CE

NT

RA

LIZ

ED

Specifications Dimensions (WxHxDmm):Fixation: DIN rail or 2 screws to wallPower supply (V):

1500 to 60ºC

175x90x40

12Vdc

Cons. (mA) without door release:Operating temperature:

Each Central Unit manages:

2.048 users.

32 accesses.

3.000 incidents (entries, exits, access

denied, alerts, etc) in memory, with no need to

download to PC.

Managing up to 1.000 intercom panels, 1.000

sensors and 1.000 relays.

The readers connectable to the Central Unit are with built-

in or external controller (ref.4420).

Technical features

All programming is done with CAC software from one or

several duly authorized on line or remote computers.

Programmation

48

CAC Central Unit (ref.4410)

Central Unit that lets you approach complex access controlinstallations handling up to 32 accesses or doors with atotal of 2048 users.A maximum of 64 central units can be connected (2048accesses).Includes four management softwares: CAC Data BaseServer, CAC Server, CAC Access and CAC Time &Attendance.The Central Unit also monitors up to 1.000 sensors and1.000 relays for automatic functions.Local (USB, RS-232) or remote (IP) connection to PC viathe corresponding module (see accessories section).

Installation

CAC Central Unitcentralized

2 wires

twisted pairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

2 wires

twisted pair

Up to 64 Central Units

2 wires

twisted pairReader

Up to 32 readers

Reader

2 wires

twisted pair

twis

ted

pair

........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

Page 51: Access Control FERMAX

CE

NT

RA

LIZ

ED

Needs CAC Data Base Server software installed(manages the SQL database) and CAC Server. Bothincluded in the central unit.Software included in the Central Unit (ref.4410) tomanage readers, user groups and advanced accesscontrol functions.Friendly graphic interface, simple and intuitive witha framework similar to Outlook©.All the options can be viewed in a hierarchic tree:doors, user profiles, schedules, automation.TCP/IP client server architecture.

CAC Access

Technical features

49

Software CAC Accesscentralized

2.048 users.

64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3

areas and 3 schedules.

4 special profiles without user restrictions.

Special treatment for vehicles (parking areas).

32 areas. They define the doors to which access is allowed.

32 schedules. They define the periods of time when access is allowed to users.

On-line record of the last 3000 incidents (entries, exits, access denied, alerts, etc).

32 weekly device activation schedules (sensors/relays).

Capacity limitation in certain rooms or premises to a number of people.

Door blocking/unblocking.

Temporary user blocking individually or by groups. Access not permitted until they are unblocked.

Option to assign timed and physical expiry of proximity cards (typical application in hotels).

Automatic change of winter/summer time.

Anti-pass back function, which prevents two people using the same identifier to access the facility. The doors that

belong to the installation perimeter are defined and are checked to see if the user is inside or outside the perimeter

when coming through them.

There are two anti-passback levels associated with the same identifier, depending on how the facility is accessed,

by pedestrian door or for vehicles (the type of door is defined by the «CAC Control Server» application).

All the users may be located outside the perimeter at a set programmed time.

Continuous testing of devices.

Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems.

Activation of devices associated to each user, presenting the identifier in a reader.

Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.

Page 52: Access Control FERMAX

CE

NT

RA

LIZ

ED

CAC Time & Attendance

Needs CAC Data Base Server software installed(manages the SQL database) and CAC Server. Bothincluded in the central unit.Software included in Central Unit (ref.4410) formanaging entry/exit of people, clock-ins andcalculating hours worked for wages processing.Friendly graphic interface, simple and intuitive witha framework similar to Outlook©.All the options can be viewed in a hierarchic tree:doors, user profiles, schedules, automation.

50

Technical features

Software CAC Time & Attendancecentralized

2048 users.

64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3

areas and 3 schedules.

4 special profiles without user restrictions.

32 schedules. They define the periods of time when access is allowed to users.

Vacations (20 holidays and 3 vacation periods).

Record of the last 3.000 incidents (entries, exits, etc).

People location control for emergency evacuations.

Allocation of events in the exit readers by PIN code (doctor, commercial visit, etc).

Generation of daily, weekly or monthly information: actual hours, delays, overt ime, etc.

Door blocking/unblocking.

Temporary user blocking individually or by groups. Access not permitted until they are unblocked.

Automatic change of winter/summer time.

Manual change of anomalies in employee presence.

Continuous testing of devices.

Firmware update in installation. Lets you update the central unit with new versions or functions and resolve problems.

Activation of devices associated to each user, presenting the identifier in a reader.

Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.

Page 53: Access Control FERMAX

CE

NT

RA

LIZ

ED

All programming is done with Wincom+ software from

one or several duly authorized on-line or remote computers.

Central Unit MDS (ref.2405)

Central Unit that lets you approach complex MDS audioand video door entry systems combined with accesscontrol functions.Each Central Unit is able to manage up to 10.000 houses,1.022 users and 31 audio or video door entry or accesscontrol panels.Can connect up to a maximum of 63 central units (approx.2.000 accesses).Wincom+ management so f tware inc luded.The Central Unit also monitors up to 1.000 sensors and1.000 relays for automatic functions.Local (USB, RS-232) or remote (IP) connection to PC viathe corresponding module (see accessories section).

Each Central Unit manages:

1.022 users.

31 accesses (audio, video door entry or access

control readers).

3.000 incidents (entries, exits, access

denied, alerts, etc.) in memory, with no need to

download to PC.

Managing up to 1.000 intercom panels, 1.000

sensors and 1.000 relays.

Capacity of 10 guard units.

The readers connectable to the Central Unit are with built-

in or external controller (ref.4420).

Technical features

Programmation

Installation

2 wires

twisted pair

Central Unit(ref.2405)

2 wires

twisted pair

Reader

Up to 64 Central Units

2 wires

twisted pair

Up to 32 elements

2 wires

twisted pair

twis

ted

pair

Power supply 12Vdc

Video panel Audio panel

Up to 32 elements

................

51

Central Unit MDScentralized

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

2 wires

Page 54: Access Control FERMAX

CE

NT

RA

LIZ

ED

Software included in Central Unit (ref.2405) tomanage complex audio, video door entry andaccess control installations.Management of all the parameters from a uniquesoftware with framework similar to Outlook©.All the options can be viewed in a hierarchic tree:doors, user profiles, schedules, automation.

Wincom+ Software

52

Wincom+ Softwarecentralized

Technical features

1022 users

64 user groups (profiles). Each one defines the restrictions that are applied to the group by allocation of up to 3

areas and 3 schedules.

32 areas. They define the doors to which access is allowed.

32 schedules. They define the periods of time when access is allowed to users.

On-line record of the last 3.000 incidents (entries, exits, access denied, alerts, etc), all exportable to Excel.

Vacations (20 holidays and 3 vacation periods).

Installation configuration and testing.

2 user levels (administrator, operator).

Lift control.

Perimeter anti-passback function.

Capacity limitation in certain rooms or premises to a number of people.

Door blocking/unblocking.

Activation of devices associated to each user, presenting the identifier in a reader.

Relay activation from a reader with keyboard and proximity. Alarms connection and disconnection.

Page 55: Access Control FERMAX

CE

NT

RA

LIZ

ED

Installation

Door controller without memory (ref.4420).Manages the devices present in each access: upto two readers (if they are entry and exit), electriclock, door sensor and exit button.Installation indoors and separated from readerfor higher security.Input Wiegand-26, magstrip or ibutton.

Door Controller (ref.4420)

Specifications Dimensions (WxHxDmm): 85x88x25Power supply (V): 12Vdc

Consumption: 15mA / 100mAOperating temperature: 0 to 60ºC

Connection between controllers consists of 2 power cables

and one twisted pair for data.

Admits an exit and entry reader, electric lock relay, auxiliary

relay for other functions, connection button, door sensor

and free access.

Dip switch to encode the door number, reader type and

access type (pedestrian or vehicle).

Necessary in vehicle accesses for connection of entrance

or exit detection coils.

Lets you connect any reader with Wiegand-26 input,

Magstrip (Aba Track II or Dataclock).

Lets you connect button key type readers Dallas i-button

and matrix keypads in 8-bit burst format.

Test button to check the correct installation of all devices

connected to the controller.

Technical features

Installation in mechanism box 100x100mm or surface

mounted with 2 screws (included).

Central Unit(ref.4410 o ref.2405)

2 wires

twisted pair

Reader

Up to 64 Central Units

Up to 32 readers

Reader

2 wires

twisted pair

twis

ted

pai

r

2 wires

7 wire

s

7 wire

s

7 wire

s

Reader Reader Reader

7 wire

s

7 wire

s

53

Controllercentralized

A 0 B

1 2 3

4 5 6

7 8 9

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Power supply 12Vdc

Doorcontrollerref.4420

Doorcontrollerref.4420

Doorcontrollerref.4420

Doorcontrollerref.4420

Doorcontrollerref.4420

Page 56: Access Control FERMAX

CE

NT

RA

LIZ

ED

54

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0712Vdc

200 to 60ºC

130x128x18115x114x45130x128x33

43

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref. 4410).Programmation

Exit pushbutton input, door sensor input and electric lock

relay.

2-wire cables for power supply and twisted pair for data.

Dip switch to encode door number and electric lock activation

timing.

Requires external relay (ref.2013) if activating electric lock

with consumption over 500mA, inverted function or external

device (motor, barrier).

Technical features

Access control keypad with capacity up to 100different 4- to 6-digit codes.Manufactured in aluminium.Flush or surface mounted (ref .8851).Recommended for interiors and exteriors.Reader and controller in the same module.No door controller required (ref.4420).

City Memokey MDS (ref.23291)

2 wires

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair ........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

Memokeycentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

Page 57: Access Control FERMAX

CE

NT

RA

LIZ

ED

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0912Vdc

0 to 60ºC

135x130x18115x100x45135x131x42

53

Protection against knocks (IK):Power supply (V):Operating temperature:

Access control keypad with capacity up to 100 different4- to 6-digit codes.Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for inter iors and exter iors.Reader and controller integrated in the same module.Ideal for troubled zones or districts, offices, banks, etc.No door controller required (ref.4420).

Bruto Memokey MDS (ref.2553)

Programmation Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).

Exit pushbutton input, door sensor input and electric lock

relay.

2-wire cable for power supply and twisted pair for data.

Dip switch to encode door number and electric lock

activation timing.

Requires external relay (ref.2013) if activating electric lock

with consumption over 500mA, inverted function or

external device (motor, barrier).

Technical features

Installation

2 wires

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader Reader

2 wires

twistedpair

twis

ted

pair

........ ........

Power supply 12 Vdc

Up to 32 readersUp to 32 readers

Up to 32 readers

55

Memokeycentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

Page 58: Access Control FERMAX

CE

NT

RA

LIZ

ED

56

Specifications

Installation

City Memokey&Private WG (ref.4480)Dual technology access control reader: proximity and keypad.Stand-alone or joint operation for greater security: PIN code+ card.Manufactured in aluminium in City style.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.4420) required for operation.

Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

Memokey&Private WGcentralized

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Metalic box (WxHxDmm):Environmental protection (IP):

0712Vdc30mA

0 to 60ºC

130x175x18115x162x45130x175x33154x203x50

43

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release: Operating temperature:

Programmation Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).

Technical features Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the door

opening mechanism nor the exit button connection are

built-in. These functions are supported by door controller

(ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: open door / closed / power supply.

2 wires

twistedpair

........

Reader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

Door controller(ref.4420)

7 wires

7 wires

7 wires 7 wires

Page 59: Access Control FERMAX

CE

NT

RA

LIZ

ED

Specifications

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501Identifiers

Loft Memokey&Private WG (ref.4550)Dual technology access control reader: proximity andkeypad.Stand-alone or joint operation for higher security: PIN code+ card.Manufactured in ABS plastic.Surface mounted.Recommended for interiors.Ideal for office screen profiles.Includes a 50cm cable.Door controller (ref.4420) required for operation.

Installation

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

57

Memokey&Private WGcentralized

60x130x23

66

Dimensions (WxHxDmm):Flush box (not required):Surface box (not required):Environmental protection (IP):

0612Vdc40mA

0 to 60ºC

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

Programmation Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).

Technical features Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the door

opening mechanism nor the exit button connection are

built-in. These functions are supported by door controller

(ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: open door / closed / power supply.

2 wires

twistedpair

........

Reader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 BDoor controller(ref.4420)

7 wires

7 wires

7 wires

Page 60: Access Control FERMAX

CE

NT

RA

LIZ

ED

58

City Private MDS (ref.23351)

Specifications

Installation

Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Reader and controller integrated in the same module.No door controller required (ref.4420).

Technical features Exit pushbutton input, door sensor input and electric lock

relay.

2 wire cables for power supply and twisted pair for data to

central unit.

Dip switch to encode door number and electric lock activation

timing.

Requires external relay (ref.2013) if activating electric lock

with consumption over 500mA, inverted function or external

device (motor, barrier).

Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).Programmation

2 wires

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair ........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

Privatecentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0712Vdc

550 to 60ºC

130x128x18115x114x45130x128x33

43

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

Page 61: Access Control FERMAX

CE

NT

RA

LIZ

ED

City Private WG (ref.4490)

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501Identifiers

Specifications

Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted (ref.8851).Recommended for interiors and exteriors.Door controller (ref.4420) required for operation.

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

Installation

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair

........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

Private WGcentralized

59

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

1 2 3 A

654 0

B987

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Protection environmental (IP):Protection against knocks (IK):Power supply (V):

30mA0 to 60ºC

6/5 cmRS-485/USB

130x128x18115x114x45130x128x33

4307

12Vdc

Cons. (mA) without door release:Temperature operating:Reading distance(card/keyring):PC Interface:

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

Programmation Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).

Technical features Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the door

opening mechanism nor the exit button connection are

built-in. These functions are supported by door controller

(ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: open door / closed / power supply.

1 2 3

4 5 6

7 8 9

A 0 B

Door Controller(ref.4420)

2 wires7 wires

Page 62: Access Control FERMAX

CE

NT

RA

LIZ

ED

Specifications

Identifiers ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

60

Technical features Exit pushbutton input, door sensor input and electric lock

relay.

2-wire cables for power supply and twisted pair for data.

Dip switch to encode door number and electric lock activation

timing.

Requires external relay (ref.2013) if activating electric lock

with consumption over 500mA, inverted function or external

device (motor, barrier).

Programming from PC software PC corresponding to installed

Central Unit (ref. 2405 or ref.4410).Programmation

Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Reader and controller integrated in the same module.Ideal for troubled zones or districts, offices, banks, etc.No door controller required (ref.4420).

Bruto Private MDS (ref.2552)

Installation

2 wires

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair ........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

Privatecentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

1 2 3 A

654 0

B987

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0912Vdc

550 to 60ºC

135x130x18115x100x45135x131x42

53

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

( restricted area )

PRIVATE ACCESS CONTROL

1 2 3

4 5 6

7 8 9

A 0 B

Page 63: Access Control FERMAX

CE

NT

RA

LIZ

ED

Specifications

Installation

Identifiers ref.23361 ref.2336 ref.2363 ref.2364 ref.44501

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):

300 to 60ºC

4/2 cmRS-485/USB

135x130x18115x100x45135x131x42

5309

12Vdc

Cons. (mA) without door release:Operating temperature:Reading distance(card/keyring):PC Interface:

Bruto Private WG (ref.4510)Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Vandal-proof panel.Flush or surface mounted (ref.2778).Recommended for interiors and exteriors.Ideal for troubled zones or districts, offices, banks, etc.Door controller (ref.4420) required for operation.

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair

........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

7 wires

61

Private WGcentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

( restricted area )

PRIVATE ACCESS CONTROL

( restricted area )

PRIVATE ACCESS CONTROL

2 wires

Programmation Programming from PC software PC corresponding to

instal led Central Unit (ref. 2405 or ref.4410).

Technical features Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the door

opening mechanism nor the exit button connection are

built-in. These functions are supported by door controller

(ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: open door / closed / power supply.

Door Controller(ref.4420)

1 2 3

4 5 6

7 8 9

A 0 B

7 wires

Page 64: Access Control FERMAX

CE

NT

RA

LIZ

ED

62

Specifications

Private Loft WG (ref.4560)

Proximity card reader with capacity up to:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in ABS plastic.Surface mounted.Recommended for exteriors.Ideal for office screen profiles.Door controller (ref.4420) required for operation.Includes a 50 cm cable.

Installation

Technical features

Programmation Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).

2 wires

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair

......... ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

7 wires

ref.23361 ref.2336 ref.2336 ref.2364 ref.44501

Withoutpersonalizing and with

magnetic strip.

Customizable(photo, name,company...)

For replacementwith magnetic

strip.

Without personalizingand without

magnetic strip.

Proximitykeyring

Identifiers

Private WGcentralized

1 2 3 A

654 0

B987

Central Unit(ref.4410)

1 2 3

4 5 6

7 8 9

A 0 B

Dimensions (WxHxDmm):Environmental protection (IP):Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:

0 to 60ºC

8/6 cmRS-485/USB

60x130x236606

12Vdc40

Operating temperature:Reading distance(card/keyring):PC Interface:

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the door

opening mechanism nor the exit button connection are

built-in. These functions are supported by door controller

(ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Built-in status LEDs: open door / closed / power supply.

Door Controller(ref.4420)

1 2 3

4 5 6

7 8 9

A 0 B

7 wires

Page 65: Access Control FERMAX

CE

NT

RA

LIZ

ED

City key button MDS (ref.23261)

Installation

Identifiers

Specifications

Access control reader whose operation is based onphysical contact between the reader head (socket)and authorized identi f ier (plug ref.2328).Number of users:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted.Recommended for interiors and exteriors.No door controller required (ref.4420).

Technical features Exit pushbutton input, door sensor input and electric lock

relay.

2-wire cables for power supply and twisted pair for data.

Dip switch to encode door number and electric lock activation

timing.

Requires external relay (ref.2013) if activating electric lock

with consumption over 500mA, inverted function or external

device (motor, barrier).

Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).Programmation

2 wires

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair ........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

63

Key Buttoncentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0712Vdc

250 to 60ºC

130x128x18115x114x45130x128x33

43

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

1 2 3

4 5 6

7 8 9

A 0 B

Key button identifier (ref.2328).

Page 66: Access Control FERMAX

CE

NT

RA

LIZ

ED

64

Specifications

City key button WG (ref.2315)

Installation

Identifiers

Access control reader whose operation is based onphysical contact between the reader head andauthorized identifier (ref.2328).Number of users:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Manufactured in aluminium.Flush or surface mounted.Recommended for interiors and exteriors.Door controller (ref.4420) required for operation.

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair

........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

7 wires

2 wires

Key Button WGcentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0712Vdc

300 to 60ºC

130x128x18115x114x45130x128x33

43

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

Programmation Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410).

Technical features Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the door

opening mechanism nor the exit button connection are

built-in. These functions are supported by door controller

(ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

Key button identifier (ref.2328).

Door controller(ref.4420)

1 2 3

4 5 6

7 8 9

A 0 B

7 wires

Page 67: Access Control FERMAX

CE

NT

RA

LIZ

ED

Bruto key button MDS (ref.2554)

Specifications

Identifiers

Access control reader whose operation is based on physicalcontact between the reader head and authorized identifier(ref.2328).Vandal-proof panel.Manufactured in aluminium.Flush or surface mounted.Reader and controller integrated in the same module.Recommended for interiors and exteriors.Ideal for troubled zones or districts, offices, banks, etc.No door controller required (ref.4420).

Technical features Exit pushbutton input, door sensor input and electric lock

relay.

2-wire cables for power supply and twisted pair for data.

Dip switch to encode door number and electric lock activation

timing.

Requires external relay (ref.2013) if activating electric lock

with consumption over 500mA, inverted function or external

device (motor, barrier).

Programming from PC software corresponding to Central

Unit installed (ref.2405 or ref.4410).Programmation

Installation

2 wires

twistedpairReader

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.2405 or 4410)

2 wires

twistedpair

Up to 64 Central Units

2 wires

twistedpairReader

Up to 32 readers

Reader

2 wires

twistedpair

twis

ted

pair

........ ........

Power supply 12 Vdc

1 2 3

4 5 6

7 8 9

A 0 B

Up to 32 readersUp to 32 readers

65

Key Buttoncentralized

1 2 3 A

654 0

B987

1 2 3

4 5 6

7 8 9

A 0 B

Central Unit(ref.4410)

Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):Environmental protection (IP):

0912Vdc

250 to 60ºC

135x130x18115x100x45135x131x42

53

Protection against knocks (IK):Power supply (V):Cons. (mA) without door release:Operating temperature:

Key button identifier (ref.2328).

1 2 3

4 5 6

7 8 9

A 0 B

Page 68: Access Control FERMAX

CE

NT

RA

LIZ

ED

66

Unique and exclusive code per emitter.

Includes 12Vdc battery.

Range: 30m.

Frequency: 433,92 MHz.

Consumption in transmission: 10mA

Consumption in standby: 0.1mA

Technical features

Specifications Dimensions (WxHxDmm): 53x42x12mm

Compatible with Ref.7960 Villa Receiver (stand-alone).

Ref.1065 MDS Receiver (centralized).

Ref.2464 Secondary MDS Receiver (centralized).

Power supply 12 Vdc

twisted pair

Radiofrequencycentralized

Radio frequency emitter 433,92 MHz.Digital Technology.New and highly robust design.Dual channel emitter that can trigger two relays.Secure, unique, non configurable code exclusiveseries per emitter.Emitters must be authorized/cancelled in the receivers.

Digital RF emitter (ref.24651)

Installation

RF emitterref. 24651

Central Unitref.4410

RF Receiverref. 1065

2

Page 69: Access Control FERMAX

CE

NT

RA

LIZ

ED

Specifications Dimensions (WxHxDmm): 53x36x13mm

Compatible with Ref.7960 Villa Receiver (stand-alone).

Ref.1065 MDS Receiver (centralized).

Ref.2464 Secondary MDS Receiver (centralized).

Power supply 12 Vdc

twisted pair

67

In addition to the RF functions, incorporates proximity

card electronics for use in proximity reader.

Includes 12Vdc battery.

Range: 30m.

Proximity reader range: 2 cm.

Frequency: 433,92 MHz.

Consumption in transmission: 10mA

Consumption in standby: 0.1mA

Technical features

Radio frequency emitter 433,92 MHz.Dual technology.New and highly robust design.Dual channel emitter that can trigger two relays.Secure code, unique, non configurable and exclusiveas standard per emitter.Emitters must be authorized/cancelled in the receivers.Internally integrates proximity card electronics so canbe used as a dual channel emitter or a substituteidenti f ier for proximity cards or keyrings.

RF Dual emitter (ref.25511)

Radiofrequencycentralized

Central Unitref.4410

2Installation

RF emitterref.25511

RF receiverref.1065

Page 70: Access Control FERMAX

CE

NT

RA

LIZ

ED

68

Specifications Dimensions (WxHxDmm): 90x165x55mm

Includes rigid antenna, 25 cm.

Optionally, by adding card (ref.7934), we can convert

the receiver into dual channel.

Reception frequency: 433,92 MHz.

Sensitivity: 3 mV

Relay contact: 2 A max.

Power supply: 12Vdc

Consumption: 110 mA in standby.

Dip-switch to configure access number.

Technical features

2 wires

twisted pair

Central Unit(ref.2440 or 2405)

2 wires

twisted pair

Receiver

Up to 64 Central Units

2 wires

twisted pair

Up to 32 readers

2 wires

twisted pair

twis

ted

pair

Power supply 12Vdc

Video panel Reader

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

Single channel receiver 433.92MHzDigital Technology.When code emitted by the digital (ref.24651) ordual (ref.25511) remote control is received, thereceiver closes the circuit activating the electriclock or automatic door.Mounted in watertight box (IP65) in ABS.

MDS Receiver (ref.1065)

Radiofrequencycentralized

Compatible with Digital emitters (ref.24651)

Dual emitters (ref.25511)

Emitter RFRef.79561

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

Page 71: Access Control FERMAX

twis

ted

pai

r

Door Controller(ref.4420)

CE

NT

RA

LIZ

ED

Specifications Dimensions (WxHxDmm):Flush box (included):Surface box (WxHxDmm):

4307

0 to 60ºC

130x128x18115x114x45130x128x33

Environmental protection (IP):Protection against knocks (IK):Operating temperature:

City Fingerprint WG (ref.6990)

Installation

Technical features

Programmation Programming from PC software corresponding to Central

Unit installed (ref.2405 or ref.4410).

twisted pair

Central Unit(ref.2405 or ref.4410)

2 wires

twisted pair

Reader

Up to 64 Central Units

2 wires

twisted pair

Up to 32 readers

2 wires

twisted pair

Power supply 12Vdc

Video panel Audio panel

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

2 wires

69

Fingerprint WGcentralized

Fingerprint reader with thermal sensor withstorage capacity:- 1.020 users with MDS central unit (ref. 2405).- 2.048 users with CAC central unit (ref.4410).Operating mode: 1 or 2 fingerprints per person.Manufactured in aluminium in new City style.Flush or surface mounted.Recommended for interiors and exteriors.Reader and controller separated.Door controller required (ref.4420).

1 2 3 A

654 0

B987

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the door

opening mechanism nor the exit button connection are built-

in. These functions are supported by door controller (ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

2 status signal LEDs: door open/closed.

Display 7 3-digit segments.

Infrared receiver for programming.

Programmable relay timings (monostable, bistable).

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

7 wires

Page 72: Access Control FERMAX

CE

NT

RA

LIZ

ED

70

Programmation Programming from PC software corresponding to installed

Central Unit (ref. 2405 or ref. 4410).

The audio or video door entry panel is located on the

outside. It is possible to set up a configuration in the

panel intuitively including a reader (ref.6989) for greater

security and more convenient access.

Installation

Specifications Environmental Protection (IP):Protection against knocks (IK):Power supply (V):

6/602A (NA,NC)

0 to 60ºC

4307

12Vdc

Cons. (mA) without door release:Relay contact:Operating temperature:

Output in Wiegand-26 bit or Dataclock format.

Wiegand (WG) readers let you equip the access control

installation with anti-sabotage security, as neither the

door opening mechanism nor the exit button connection

are built-in. These functions are supported by door

controller (ref.4420).

The reader can be used with other door controllers using

Wiegand-26 or Dataclock protocols.

2 status signal LEDs: door open/closed.

Display 7 3-digit segments.

Infrared receiver for programming.

Programmable relay timings (monostable, bistable).

Technical features

City fingerprint module WG (ref.6989)

Fingerprint reader with thermal sensor with storagecapacity:- 1.020 users with MDS central unit (ref. 2405).- 2.048 users with CAC central unit (ref.4420).Fitted in CityMax audio or video door entry systemoutdoor panel spare spaces for enhanced security inthe home.Door controller (ref. 4420) required for operation.

Fingerprint WGcentralized

2 wires

twisted pair

Central Unit(ref.2405 or ref.4410)

2 wires

twisted pair

Reader

Up to 64 Central Units

2 wires

twisted pair

Up to 32 elements

2 wires

twisted pair

twis

ted

pair

Power supply 12Vdc

Video panel Reader

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

Page 73: Access Control FERMAX

Central Unit(ref. 4410 or ref.2405)

2 wires

twisted pair

Reader

Up to 64 Central Units

2 wires

twisted pair

Up to 32 readers

2 wires

twistedpair

twis

ted

pai

r

Power supply 12Vdc

Video panel Reader

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

1 2 3

4 5 6

7 8 9

A 0 B........

Up to 32 readers

2 wires

1 2 3

4 5 6

7 8 9

A 0 B

1 2 3

4 5 6

7 8 9

A 0 B

Door Controller(ref.4420)

1 2 3

4 5 6

7 8 9

A 0 B

2 wires

CE

NT

RA

LIZ

ED

Programmation Programming from PC software corresponding to installed

Central Unit (ref.2405 or ref.4410). Card programmer

(ref.4460) required to memorize fingerprint samples in

the Mifare cards.

Installation

Specifications Power supply (V): 12Vdc

Dual technology: fingerprint and Mifare proximity card.

The reader compares the fingerprint stored in the card

and the sample read by the sensor.

Power supply 12Vdc.

2-wire cables for power supply and twisted pair for data.

One Mifare card (ref.4440) required for each user.

Technical features

Identificadores Mifare card with memory (ref.4440).

twisted pair

71

Fingerprint Readercentralized

Fingerprint (ref.4470)

Fingerprint reader with optical sensor and capacity tostore:- 1.020 users with MDS central unit (ref.2405).- 2.048 users with CAC central unit (ref.4410).Surface mounted for interiors.Door controller (ref.4420) required for operation.

7 wires

Page 74: Access Control FERMAX

Accessories common to all systems.

Page 75: Access Control FERMAX

A c c e s s o r i e s

Page 76: Access Control FERMAX

cent

raliz

ado

AC

CE

SS

OR

IES

E lec tr ic Lock

Device that lets you unblock the door temporarily in safe conditions: identifier accepted or opening from inside bymeans of the exit button. There are several models distinguished by different operating features, installation and powersupply.Depending on the type of protection against electrical power cuts:Normal operation (fail secure). The door is unblocked when the electric lock is powered. As an advantage, if there isa power cut the door does not unlock. The NO (normally open) terminal is connected from the electric lock relay.Inverted operation (fai l safe). The door remains blocked while the electric lock is powered.It is unlocked by cutting off the power. An advantage is that if there is a power cut, the door does not block (firesystems).According to the type of installation, there are:Electrical lock/door release. Recommended in installations where we want to combine with the traditional lock andare normally installed embedded in the door frame. When activated, releases the latch to allow the door to open.Electromagnetic door release. Usually installed when there are security requirements against fire: outward openingdoors, power shutoff during the f ire alarm to faci l i tate evacuation. They are inverted type.An iron strip is placed in the leaf of the door and an electromagnet in the frame so that when the door is closed theirfaces are touching. The door stays closed while the electromagnet attracts the strip.Depending on the force with of attraction, it can resist pulling or pushing to try to open the door.The force is usually measured in Kg. When there is no space in the door frame to fit the lock or if we do not want todrill it, it can be mounted on the wall with special brackets.According to the type of power supply, there are:DC current. Characterized by being quiet. Inverted operation electric locks must be this type.AC current. They are noisy compared with DC locks. They generally have a higher consumption and work better indoors subject to some type of pressure: wind, bolt friction, etc.There are door release models with a built-in door sensor to detect if the door stays open accidentally.

74

Squares for emagnetics

door lock:

- For doors that open from inside to outside. ref.3077 Square for ref.3051

ref.3079 Doble square Z

- For doors that open from outside to inside. ref.3078 Square for ref. 3052

Accessoriesstand-alone/stand-alone in network/centralized

ref. Electr

iceM

agne

tic

3071 E N 12Vac 780 21x75x27 -40 a +120ºC E2953 E N 12Vac 780 • 20x101x28 -40 a +120ºC E2958 E N 12Vdc 150 20x101x28 -40 a +120ºC E29580 E N 12Vdc 150 • 20x101x28 -40 a +120ºC E2967 E I 12Vdc 150 20x101x28 -40 a +120ºC E29670 E I 12Vdc 150 • 20x101x28 -40 a +120ºC E3050 M 500

300Kg I 12/24 Vdc 250 229x39x26 -40 a +120ºC E3051 M 500

500Kg I 12/24 Vdc 250 229x39x26 -40 a +120ºC S3052 M 500

300Kg I 12/24 Vdc 250 229x39x26 -40 a +120ºC S

Normal

Invert

ed

Power

supp

ly

Door s

enso

r

Dimen

sions

Operat

ing te

mperat

ureFlu

shSu

rface

Consu

mption

(mA)

Page 77: Access Control FERMAX

AC

CE

SS

OR

IES

Power Suppl ies

75

Accessoriesstand-alone/stand-alone in network/centralized

When choosing a suitable power supply it is necessary to consider the consumption of all the elements in the system,especially the electric lock. It is recommended to use a magneto-thermal switch not shared with any other equipmentto avoid power supply disconnections caused by them.

It is recommendable to use an emergency supply system (with battery) to prevent doors blocking or unblocking in theevent of power cuts. In centralized installations with long distances it will be necessary to place additional power sourcesin the access to prevent tension drops in the wiring.

REF. 4800 POWER SUPPLY 12VAC/1,5ARecommended for stand-alone readers when we want touse AC locks. DIN4.

REF. 8791 EMERGENCY POWER SUPPLY 12Vac/1,5AIncludes Ni-Cd battery 750mA. In emergency supplies12Vdc.Includes Ni-Cd battery 750mA. In emergency supplies12Vdc.

REF. 4813 POWER SUPPLY 12VDC/2AGeneral installation power supply for centralized system.

REF. 2060 BATTERY ADAPTER 12VDCInstalled between 12Vdc power supply and the system.With externa l Lead-Acid bat tery connect ion.If the input tension falls below 11Vdc it switches automaticallyto the battery.

REF. 2070 BATTERY 12V/2,2A Lead-Acid battery without maintenance for small installationsor an access power supply.

REF. 2337 BATTERY 12V/ 7ALead-Acid battery without maintenance for large installations.

ref.4800

ref. 4813

ref.2060

Page 78: Access Control FERMAX

cent

raliz

ado

AC

CE

SS

OR

IES

Door Sensor

Power Cutoff

Desktop Proximity Reader

76

Accessoriesstand-alone/stand-alone in network/centralized

REF. 4475 POWER CUTOFFLets you disconnect the electrical current to the devices in a roomwhen the user is not in. For connection, it is necessary to introducethe user proximity card in the cutoff (only works with proximitycards). When the user leaves the room they remove the card fromthe cutoff and then have 10 seconds courtesy to leave the room.

Designed to be used as a complement to the stand-alone orcentralized proximity readers, since the same cards are used. Theuser is obliged to remove the card from the cutoff; otherwise theywill not be able to open the door of the room.

Embedded instal lat ion in mechanism box 60x70mm.Operating at 230V. Cutoff power: 6000W.

Proximity technology: EM, TEMIC, RF256 and TK cards.

REF. 1076 MAGNETIC CONTACTSurface installation between door and frame.

Connected to the door sensor input of the controllers.

Lets you authorize proximity identifiers quickly and easily by PCwith management software.PC connection: RS-232. Cable included.Power supply 230Vac by adaptor (included).

230Vac

3

RS-232

ref.2349

installation

power supply

Page 79: Access Control FERMAX

AC

CE

SO

RIE

S

Accessoriesstand-alone in network/centralized

Adaptor RS-232 to RS-485 (ref.2338) Adaptor RS-232 to RS-485 (ref.2466)

77

The system operating mode configuration, user authorizations and cancellations and restrictions are handled via PC andsent to the central unit so that it works independently. The information generated by the installation (events) must becommunicated to the PC in real time. To set up these communications, the PC must be connected to the central unit.The connection can be made locally or remotely, using one of the following devices:

2

3

RS-232

ref. 2466

Connection between PC and central unit (or network ofCUs).Also lets you connect the modem to the central unit forremote management.PC connection: RS-232 max. 30 mts. (cable 3 mtrsincluded).Connection to central: RS-485 (twisted pair).Max. 1200 mts.DIN6 format (surface mounted and DIN rai l ) .Power supply 230Vac.

Programming of addresses and parameters to decodersfrom the PC.Used for maintenance of facilities that do not have thePC permanently connected, as an installer tool.Includes an RS-232 cable with DB-9 connector for PCconnection.

Adaptor USB to RS-485 (ref.24661)

Connection between PC (USB) and central unit.Direct power supply from USB.Includes driver.

IP Adaptor (ref.1087)

Communication between management PC and theinstallation using IT network (Ethernet), avoiding additionalwiring.Connection to central unit by programmer (ref. 2466).An IP address must be configured to connect to thenetwork using the software included.Remote management via Internet if the protection devices(Firewall) in the IT installation allow it (specialized personnelrequired to configure router for Internet access).

Power supply 230Vac by adaptor included.Ethernet connection RJ45.

2

3

RS-485

RS-232

230 Vac

ref.2338

PC Management Modules

twisted pair

twisted pair

2 RS-485

USB

PC

Ref.24661

twisted pair

2

3

RS-232

ref. 2466

IP

ref.1087

RJ-45 RJ-45

PC

twisted pair

2

Page 80: Access Control FERMAX

cent

raliz

ado

AC

CE

SS

OR

IES

In the installation it is possible to connect up to 1000 relays in the same decoder bus, to activate different devices in

response to the activation of sensors or trigger them independently. The relays are implemented by 'relay decoder'

containing 8 2 Amp. relays with NA and NC output. The relay decoder connects to the decoder bus, which powers it.

For each output, timing (1 to 255 seconds or indefinite) and the initial status (active or standby) are configured.

78

Accessoriescentralized

Several sensors may be connected to the installation (up to 1000) to carry out automated activities based on the sourceof the detection. The sensors must be potential free contact, such as switches, pushbuttons, magnetic contacts,volumetric detectors, photoelectric barriers, etc.

These sensors are managed by 'sensor decoders’, with capacity for 8 entrances, and connected to the central unit bythe decoder bus, from which it is powered.NA or NC operating mode and the type of trigger (instant or delay up to 127 minutes) must be configured.

For each group (100 sensors), the actions to take are indicated (not exclusive):

Communicate the incident to the central console (security post).

Activate one or several relays (ref. 2430) (always the same or different depending on the sensor).

Switch status of a relay.

Monitor the incident on the control computer (control post).

Activate the electric lock of a given door.

Subordinate the action to the simultaneous activation of another sensor (double signalling to avoid false alarms).

Sensors can be enabled and disabled during a set schedule by means of the schedule planner or from the

access control readers, when a user identi f ier associated with a sensor is presented.

The most frequent applications of the sensors are the following:

Technical alarms: Alarm messages in the PC control. Power failure, water leak, intrusion, etc...

Construction of pushbutton panels for timed activation of devices: vehicle barriers, opening doors, hallway

lighting, etc.

Door blocking depending on the status of other doors.

SENSOR DECODER ref.2429

RELAY DECODER ref.2430

Technical Alarms and Automation

Page 81: Access Control FERMAX

AC

CE

SS

OR

IES

There are several ways to trigger the relays:

Specifications

79

ref.5918

ref.2537

Automatic connection and disconnection of devices: heating,refrigeration, lighting, etc.Alarms connection and disconnection.Activation of sirens and warning lights.Unblocking of doors during a set schedule.

Schedule planner: activates and deactivates relays according to a set weekly schedule (up to 32 daily plans).From the access control readers. Each user can have a relay associate with their identifier so that when it is presented,the associated relay status is switched while activating the door release.From the central guard - unit. Any relay can be activated or deactivated by entering its number and the desired status(active / standby).When a sensor or combination of sensors is activated.When the maximum capacity of a zone is reached.When there is someone in a zone.

Typical applications are:

Programming the sensor and relay decoders is done with thedecoder programmer (ref. 2466).

Dimensions (WxHxDmm):Nº devicesMaximum capacity/centralActivation typeProg. detection/activationDetection/activation.Power supplyConsumption (mA) min/max.Temperature operating:

175x90x378 outputs

2 A NC/NA1 sec.

1..255 sec./indefinite

7/170-10ºC to +60ºC

175x90x378 inputs

Potential free contact26 sec.

1sec./127 min.

10-10ºC to +60ºC

1000

12Vdc

SENSOR DECODER RELAY DECODER

De s k t o p guard un i t

Can recieve calls from the interphone panels and allow accessto visitors. Permits access management of any door within theinstallation. Receives sensor reports in the case of manipulatedor open doors.

In installations with several guard units all calls and alarms canbe centralized in one main guard unit. To be connected to thedoor bus by means of two additional wires for the audio(ref.5918).

From the main guard unit a simple user configuration can bedone (without restrictions), no PC configuration necessary.

Dimensions (WxHxDmm):Power supply:Consumption (mA) min/max.:Operating temperature:

215x205x25012 Vdc

300-10ºC to +60ºC

175x90x3712 Vdc15/30

-10ºC to +60ºC

PANEL DECODER MAIN GUARD UNIT

Page 82: Access Control FERMAX

80

RF MDS RECEIVER

REMOTE MANAGEMENT IP MODULE

RELAY STAIRS LIGHT

EMERGENCY BATTERY MODULE 12V

EMERGENCY BATTERY 12V-2 A.

BRUTO KIT MEMOKEY STAND-ALONE

CITY KIT PRIVATE STAND-ALONE

CITY PROXIMITY READER STAND-ALONE MODULE

BRUTO PROXIMITY MDS MODULE

BRUTO PROXIMITY READER STAND-ALONE MODULE

PROGRAMMATION KEYPAD PRIVATE READER

KEY-BUTTON READER WG

KEY BUTTON IDENTIFICATOR

PROXIMITY CARD WITH MAGNETIC STRIPE

BATTERY 12VDC.6,5AMP

DIN TERMINAL DIG.FX-L 220V

CITY PRIVATE READER STAND-ALONE

CITY PRIVATE READER DESKTOP

PROGRAMMING KIT WINPROX

PROXIMITY CARD WITHOUT MAGNETIC STRIPE

CENTRAL UNIT MDS

DECODER OF 8 SENSORS MDS

DECODER OF 8 RELAYS MDS

SECUNDARY RF RECEIVER

PC INTERFACE DECODER

CITYMAX MEMOKEY MODULE

BRUTO MEMOKEY MODULE

BRUTO PROXIMITY READER MDS

BRUTO MDS DIGITAL KEYPAD

BRUTO KEY-BUTTON READER MDS

CITY PROXIMITY MDS MODULE

CITY KEYPAD MDS MODULE

BRUTO 1 SURFACE BOX MODULE

DOOR LOCK MOD.3000N-S

DOOR LOCK N-412-S

DOOR LOCK N-512-S

FLUSH EMAGNETIC DOOR LOCK 300Kg

EMAGNETIC SURFACE DOOR LOCK 500Kg

EMAGNETIC SURFACE DOOR LOCK 300Kg

UNIVERSAL MOD.450N-S DOOR LOCK

SQUARE L-2 FOR REF.3051

SQUARE L-3 FOR REF.3052

DOUBLE SQUARE

REF. DESCRIPTION

01065

01087

02013

02060

02070

02133

02260

02263

02268

02288

02306

02315

02328

02336

02337

02338

02347

02349

02351

02363

02405

02429

02430

02464

02466

02520

02523

02552

02553

02554

02560

02561

02778

02953

02958

02967

03050

03051

03052

03071

03077

03078

03079

Index of references

Page 83: Access Control FERMAX

81

CITY MEMOKEY CR 230V KIT

DIN RAIL 12 VDC 12A RELAY

KIT MEMOKEY CITY STAND-ALONE

CITY MEMOKEY READER STAND-ALONE

CITY PRIVATE KIT WITH PROXIMITY KEYRINGS

CR MEMOKEY 100 CODES KEYPAD

CR MEMOKEY 100C. CONTROLLER

LOFT MEMOKEY STAND-ALONE KIT

KIT PRIVATE LOFT STAND-ALONE

CAC CENTRAL UNIT

DOOR CONTROLLER WITHOUT MEMORY

MIFARE PROXIMITY CARD

FINGERPRINT PROGRAMMER

FINGERPRINT READER

ENERGY CUTOFF

CITYMAX BLUETOOTH MODULE

CITY BLUETOOTH READER

BLUETOOTH READER KIT

CITY MEMOKEY/PROXIMITY WG

CITY PROXIMITY READER WG

BRUTO MEMOKEY MODULE

BRUTO PROXIMITY READER WG

BRUTO 1 PRIVATE MODULE

LOFT PROXIMITY READER STAND-ALONE

LOFT MEMOKEY READER STAND-ALONE

LOFT MEMOKEY/PRIVATE READER WG

LOFT PRIVATE READER WG

MARINE FLUSH BOX ST-2

MARINE PROXIMITY READER MODULE STAND-ALONE

MARINE MEMOKEY KEYPAD

POWER SUPPLY 12VAC/1,5A

POWER SUPPLY DIN10 230VAC/12VAC+18VDC-1.5A

POWER SUPPLY 12VDC/2A

CITY FINGERPRINT READER KIT

CITY FINGERPRINT MODULER READER

CITY FINGERPRINT READER

SINGLE CHANNEL 433Mhz RF RECEIVER

RF RECEIVER FOR SHOPS 433Mhz - 230 V

RADIOFRECUENCY FOR SHOPS KIT

STANDARD RADIOFRECUENCY KIT

SECURITY RADIOFRECUENCY KIT

RF RECEIVER FOR GARAGES

RF VILLA RECEIVER

REF. DESCRIPTION

03591

03491

03600

03610

03619

03620

03621

03623

03624

04410

04420

04440

04460

04470

04475

04476

04477

04478

04480

04490

04500

04510

04520

04530

04540

04550

04560

04642

04698

04699

04800

04810

04813

06988

06989

06990

07900

07903

07910

07911

07912

07952

07960

Index of references

Page 84: Access Control FERMAX

82

EMERGENCY POWER SUPPLY 12VAC/1,5A

CITY SUPERFACE BOX SERIES 1

BRUTO KEYPAD MDS MODULE

MDS KEY BUTTON READER

CITY MEMOKEY READER MDS

CITY PRIVATE READER MDS

STANDARD PROXIMITY CARD WITHOUT MAGNETIC STRIPE

RF SEGURITY EMITTER

USB CONVERTER

RF DUAL EMITTER

DOOR LOCK AD-2005

DOOR LOCK MOD.N-424-S MAX

DOOR CONTROLLER WITH MEMORY

PROXIMITY KEYRING

RF TRINARY EMITTER

REF. DESCRIPTION

08791

08851

22371

23261

23291

23351

23361

24651

24661

25511

29518

29628

44201

44501

79561

Index of references

Page 85: Access Control FERMAX

ACCESS CONTROL 1 st Edi t ion. March 2009

Page 86: Access Control FERMAX

PU

0043

0

www.fermax.com [email protected]

Audio and Video Door Entry Systems