accessory kit installation instructions · 035-17291-001-a-0903 for single package air conditioners...
TRANSCRIPT
Unitary Products Group
ACCESSORY KIT INSTALLATION INSTRUCTIONS
ELECTRIC HEAT ACCESSORY MODELS 2TP04520925 THROUGH 5458 AND 2HP04525425 THROUGH 35458
035-17291-001-A-0903
FOR SINGLE PACKAGE AIR CONDITIONERS MODELS DM, DL, DH, DU, DF, DS, DJ, DW AND HEAT PUMPS BA AND BP 6-1/2 THROUGH 12-1/2 TONS
GENERALThis instruction contains all the necessary information forfield installing the electric heaters listed in Table 1 in thesingle package air conditioners and heat pumps listedabove.
Terminal blocks, electrical connectors, wiring, and all hard-ware are supplied with these accessories.
The data in Table 1 shows the heater kW/minimum CFMlimitations. Tables 2 through 52 lists the heater combina-tions applicable to the appropriate size unit. Tables 2through 52 also contain important electrical characteristicsand limitations.
Units and ductwork are approved for zero clearance tocombustible materials when equipped with these electricheaters.
NOTE: These heater accessories may be installed before or after the unit has been set on a curb or slab.
INSTALLATION
Improper installation, adjustment, service or mainte-nance can cause injury or property damage. Therefore,only a qualified installer or qualified service personnelshould perform this conversion.
1. Disconnect all electrical power to the unit.
2. Open the following doors to the unit:
a. Electric Heat Section
b. Blower Section
c. Compressor Section
d. Wiring Section
3. Remove the patch plate in the electric heat section anddiscard.
TABLE 1: MINIMUM CFM LIMITATIONS
Heater AccessoryModel Number
Unit Model Size, Nominal Tons
6.5 7.5 8.5 10 12.5
Minimum Supply Air CFM
2TP04520925 1950 2250 2550 N/A N/A
2TP04521825 1950 2250 2550 3000 3750
2TP04522425 1950 2250 2550 3000 3750
2TP04523625 1950 2250 2550 3000 3750
2TP04525425 N/A N/A N/A 3000 3750
2HP04525425 N/A N/A N/A 3500 N/A
2HP04535425 N/A N/A N/A N/A 4000
2TP04520946 1950 2250 2550 N/A N/A
2TP04521846 1950 2250 2550 3000 3750
2TP04522446 1950 2250 2550 3000 3750
2TP04523646 1950 2250 2550 3000 3750
2TP04525446 N/A N/A N/A 3000 3750
2HP04535446 N/A N/A N/A 3000 3750
2TP04520958 1950 2250 2550 N/A N/A
2TP04521858 1950 2250 2550 3000 3750
2TP04522458 1950 2250 2550 3000 3750
2TP04523658 1950 2250 2550 3000 3750
2TP04525458 N/A N/A N/A 3500 3750
2HP04535458 N/A N/A N/A 3500 3750
2TP04520950 1950 2250 2550 N/A N/A
2TP04521850 1950 2250 2550 3000 3750
2TP04522450 1950 2250 2550 3000 3750
2TP04523650 1950 2250 2550 3000 3750
2TP04525450 N/A N/A N/A 3000 3750
2HP04535450 N/A N/A N/A 3000 N/A
035-17291-001-A-0903
2 Unitary Products Group
NOTE: Retain the screws for use in installing the electric heater.
4. Insert heater into space vacated by the patch plate andslide into place (see Figure 1).
5. Once the heater is slid into place, it must be lifted slightlyto allow screw holes to align. The heaterís frame isnotched just behind the mounting panel to allow for align-ment of the holes. Secure with screws from the patchplate.
IMPORTANT: If the inside of the electric heat access doorlooks like Figure 2, then skip to Step 18. If the electric heataccess door looks like Figure 3, then proceed as follows.
NOTE: For units with electric heat access door as shown in Figure 3, Steps 6 and 7 for Electric Heat Kits 2HP04525425, 2HP04535425, 2TP04525425 and 2TP04523625 will require two knockouts in the top and bottom. This is to accommodate the two conduit assemblies required for these heaters. All other heaters use only one conduit assembly with 1 knockout in the top and 1 knockout in the bottom of the blower section.
6. Remove the knockout(s) at the lower left corner of theblower section (see Figure 4).
7. Remove the knockout(s) in the upper left corner of theblower section (see Figure 4).
FIGURE 1 - INSERTING ELECTRIC HEATER
FIGURE 2 - ELECTRIC HEAT ACCESS DOOR WITH RAINSHIELD
FIGURE 3 - ELECTRIC HEAT ACCESS DOOR WITHOUT RAINSHIELD
FIGURE 4 - UNIT KNOCKOUTS REMOVED
KNOCKOUTS
KNOCKOUTS
035-17291-001-A-0903
Unitary Products Group 3
8. Run electric heater wires (one at a time) into the topknockout and through the raceway between the blowersection and compressor section (see Figure 5).
9. Pull enough length of wire to reach under the controlpanel to unit Terminal Block 1 from the compressor com-partment.
10. Install one end of the flex conduit assembly by sliding theconduit over the wires run in Step 8 and inserting thesnap-in connector into the top knockout (see Figure 6).
11. Run opposite end of wire down through the bottomknockout into the electric heater section (see Figure 7).
12. Install the loose end of the flex conduit by inserting thesnap-in connector into the bottom knockout (see Figure8).
13. Check to make sure that both ends of the flex conduitare snapped securely into the knockouts, flush with thesheet metal so that the foam O-ring makes a good seal(see Figure 9).
FIGURE 5 - WIRE THROUGH RACEWAY INTO COMPRESSOR SECTION
FIGURE 6 - INSTALLATION OF THE TOP SNAP-IN CONNECTOR
FIGURE 7 - WIRE IN BOTTOM KNOCKOUT
FIGURE 8 - INSTALLATION OF BOTTOM SNAP-IN CONNECTOR
035-17291-001-A-0903
4 Unitary Products Group
14. Repeat Steps 6 thru 13 if additional wiring is needed.
15. Connect wires to Terminal Block 1 on the electric heateras shown in Figure 10.
16. Connect the control wiring harness from the electricheater to the control wiring plug found in the electric heatcompartment. The plug and wiring will be found in thetop left corner of the electric heat compartment, next tothe knockouts.
17. Secure the wires in the compressor section to the suc-tion line. This is to keep the wires from interfering withthe passage of the filters.
a. IF MAIN POWER CONDUIT IS PRESENT: Secure wires to main power conduit with two wire ties.
b. IF MAIN POWER CONDUIT IS NOT PRESENT: Bun-dle wires and secure to each other with two wire ties.
FOR UNITS WITHOUT A FUSE BLOCK ACCESSORY GOTO STEP 45.
FOR ALL 208/240V 54kW HEATERS AND 208/240V 36kWHEATERS IN 10 AND 12-1/2 TON HEAT PUMPS PRO-CEED TO STEP 37.
18. Remove the knockout(s) at the lower left corner of theblower section (see Figure 11).
NOTE: For units with electric heat access door as shown in Figure 2, Steps 18 and 19 for Electric Heat Kits 2HP04525425, 2HP04535425, 2TP04525425 and 2TP04523625 require two knockouts in the top and bottom. This is to accommodate the six wires required for these two heaters (3 wires per knock-out). All other heaters use only 3 wires with 1 knock-out in the top and 1 knockout in the bottom of the blower section.
19. Remove the knockout(s) in the upper left corner of theblower section (see Figure 11).
20. Install snap bushings in the knockout(s) in the upper leftcorner of the blower section (see Figure 11).
21. Install strain relief bushings in the knockout(s) in thelower left corner of the blower section, as shown in Fig-ure 11.
22. Remove the individual power lead wires from theenclosed black flex conduit assemblies (The flex conduitcannot be used in the unit.).
23. Run wiring up through the snap bushings into the race-way.
FIGURE 9 - PROPER FOAM O-RING INSTALLA-TION
FIGURE 10 - WIRING TO HEATER ASSEMBLY
FOAM
O-RING
RED BLUE BLACK
035-17291-001-A-0903
Unitary Products Group 5
24. Run electric heater wires through raceway (one at atime) between the blower section and compressor sec-tion (see Figure 12).
25. Pull enough length of wire to reach under the controlpanel to the Terminal Block 1 from the compressor com-partment.
26. Run electrical insulation tubing over wires in the blowersection.
NOTE: The tubing is meant to protect the wiring from dam-age due to clamping in the strain relief bushing.
27. Run wire down through the strain relief bushing into the
electric heater section.
28. Clamp electrical insulation tubing in the mouth of thestrain relief bushing. Tighten the strain relief bushing onthe tubing (see Figure 13).
29. Connect wires to Terminal Block 1 on the electric heateras shown in Figure 14.
FIGURE 11 - UNIT KNOCKOUT INSTALLATION
FIGURE 12 - WIRE THROUGH RACEWAY INTO COMPRESSOR SECTION
SNAP BUSHINGS
STRAIN RELIEF BUSHINGS
FIGURE 13 - INSTALLED WIRES IN BLOWER SEC-TION
ELECTRICAL INSULATION TUBING INSTALLED IN STRAIN RELIEF BUSHINGS
WIRE TIES
035-17291-001-A-0903
6 Unitary Products Group
30. Connect the control wiring harness from the electricheater to the control wiring plug found in the electric heatcompartment. The plug and wiring will be found in thetop left corner of the electric heat compartment, next tothe knockouts.
31. Secure wires with wire ties in the electric heat andblower section. Use at least two wire ties per section(see Figure 13).
32. Secure the wires in the compressor section to the suc-tion line. This is to keep the wires from interfering withthe passage of the filters.
a. IF MAIN POWER CONDUIT IS PRESENT: Secure wires to main power conduit with two wire ties.
b. IF MAIN POWER CONDUIT IS NOT PRESENT: Bun-dle wires and secure to each other with two wire ties.
33. Remove the sheet metal rainshields from inside of elec-tric heat access door, if present (see Figure 2).
34. Seal the exposed louvered openings by applying alumi-num foil tape to the inside surface of the electric heataccess door (see Figure 15).
35. Apply aluminum foil tape to cover the three open slots inthe base pan located at the bottom of the electric heatcompartment (see Figure 16).
36. Apply silicon sealant in and around the strain relief con-nectors to thoroughly seal the holes between the blowercompartment and the electric heat compartment (seeFigure 17).
FIGURE 14 - WIRING TO HEATER ASSEMBLY
RED BLUE BLACK
FIGURE 15 - LOUVERED OPENINGS
FIGURE 16 - SLOTTED BASE PAN
SEAL WITH ALUMINUM TAPE
SEAL WITH ALUMINUM TAPE
035-17291-001-A-0903
Unitary Products Group 7
FOR UNITS WITHOUT A FUSE BLOCK ACCESSORY GOTO STEP 45.
FOR ALL 208/240V 54kW HEATERS AND 208/240V 36kWHEATERS IN 10 AND 12-1/2 TON HEAT PUMPS PRO-CEED TO STEP 37.
37. Disconnect contactor wiring from Terminal Block 1.
38. FOR UNITS WITH FACTORY MOUNTED DISCON-NECT: Mount stand off bracket to the disconnectbracket.
FOR UNITS WITHOUT FACTORY MOUNTED DISCON-NECT: Mount fuse holder to the control panel as shown inFigure 20 and go to step 40.
FIGURE 17 - STRAIN RELIEF CONNECTORS
FIGURE 18 - TERMINAL BLOCK 1
SEAL OPENINGS
WITH SILICON
FIGURE 19 - STAND OFF BRACKET INSTALLED ON DISCONNECT BRACKET
FIGURE 20 - FUSE HOLDER INSTALLED IN UNIT WITHOUT FACTORY MOUNTED DISCONNECT
DisconnectBracket
Stand OffBracket
Fuse Holder
035-17291-001-A-0903
8 Unitary Products Group
39. Attach fuse holder to mounting bracket (see Figure 21).
40. Install three fuses into fuse holder as shown in Figure 21.
41. Connect Terminal Block 1 to the bottom lugs of the fuseholder with the eight-inch 4 gauge wires included in thekit (see Figure 21).
NOTE: Use the back lugs in the Terminal Block 1 to attach the wires going to the fuse holder.
42. Install Terminal Block 2 immediately above TerminalBlock 1. Use the four holes provided with the unit asshown in Figure 21 (uninstalled) and 22 (installed).
43. Connect the contactor wires (disconnected in step 37) toTerminal Block 2.
44. Connect the fourteen-inch 4 gauge wires (supplied in thekit) from the line side of Terminal Block 2 to the top lugsin the fuse holder.
45. Pull electric heat wires under the control panel to the Ter-minal Block 1 and connect to the vacant lugs as shownin Figure 24.
46. Close all unit doors and secure.
47. Reconnect the power to the unit.
FIGURE 21 - FUSE HOLDER CONNECTED
FIGURE 22 - TERMINAL BLOCK 2 INSTALLED
Holes ProvidedFor TerminalBlock 2
4 Gauge Wires
Fuse Holder(FusesInstalled)
FIGURE 23 - FUSE BLOCK AND TERMINAL BLOCK 2 INSTALLED
FIGURE 24 - HEATER WIRES INSTALLED IN TER-MINAL BLOCK 1
BLACK REDBLUE
NOTE: WIRES ATTACHED TO TOP OF TERMINAL BLOCK 1.
035-17291-001-A-0903
Unitary Products Group 9
TABLE 2: ELECTRICAL DATA - DM/DL (6-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 3: ELECTRICAL DATA - DM/DL (6-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 6.8 18.9 38.0 40.0 43.5 45.5 50 50 50 50
2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70
2TP04522425 18.0 50.0 70.2 72.7 77.1 79.6 80 80 80 80
2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 9.0 21.7 38.0 40.0 43.5 45.5 50 50 50 50
2TP04521825 18.0 43.3 61.9 64.4 68.8 71.3 70 70 70 80
2TP04522425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90
2TP04523625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125
None -- -- 20.7 21.7 22.9 23.9 25 25 25 30
2TP04520946 9 11.3 20.7 21.7 22.9 23.9 25 25 25 30
2TP04521846 18 22.6 30.9 32.2 33.7 34.9 35 35 35 35
2TP04522446 24 30.1 40 41.2 42.7 44 40 45 45 45
2TP04523646 34 42.7 55 56.2 57.7 59 60 60 60 60
None -- -- 15.1 16.3 16.9 18.1 20 20 20 20
2TP04520958 9 9.0 15.1 16.3 16.9 18.1 20 20 20 20
2TP04521858 18 18.1 24.7 26.2 26.9 28.4 25 30 30 30
2TP04522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40
2TP04523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50
* Maximum HACR breaker of the same AMP size is applicable.
12.8 110.0 1.5 6.2 8.2 5.5 0.0
12.8 110.0 1.5
7.1 54.0 0.8
5.1 44.0
6.2 8.2
3.1 4.1
0.6 2.4 3.6
5.5 0.0
2.2 0.0460
575 1.8 0.0
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.Voltage
CompressorsOD Fan
Motors
208
230
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 6.8 18.9 48.0 50.0 53.5 55.5 60 60 60 60
2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80
2TP04522425 18.0 50.0 82.7 85.2 89.6 92.1 90 90 90 100
2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 9.0 21.7 48.0 50.0 54.2 56.7 60 60 60 60
2TP04521825 18.0 43.3 74.4 76.9 81.3 83.8 80 80 90 90
2TP04522425 24.0 57.7 92.4 94.9 99.3 101.8 100 100 100 110
2TP04523625 34.0 81.8 122.5 125.0 129.4 131.9 125 125 150 150
None -- -- 25.7 26.7 27.9 28.9 30 30 30 35
2TP04520946 9 11.3 25.7 26.7 27.9 28.9 30 30 30 35
2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45
2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60
2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70
None -- -- 19.1 20.3 20.9 22.1 20 25 25 25
2TP04520958 9 9.0 19.1 20.3 21.1 22.6 20 25 25 25
2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35
2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45
2TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60
*
12.8 110.0 1.5230
1.5 5.5 10.06.2 8.2208 110.0
460
575
12.8
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Maximum HACR breaker of the same AMP size is applicable.
6.2 8.2 5.5 10.0
7.1 54.0 0.8 3.1 4.1 2.2 5.0
5.1 44.0 0.6 2.4 3.6 1.8 4.0
035-17291-001-A-0903
10 Unitary Products Group
TABLE 4: ELECTRICAL DATA - DM/DL (7-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 5: ELECTRICAL DATA - DM/DL (7-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 39.6 41.6 45.1 47.1 50 50 50 60
2TP04520925 6.8 18.9 39.6 41.6 45.1 47.1 50 50 50 60
2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70
2TP04522425 18.0 50.0 70.2 72.7 77.1 79.6 80 80 80 80
2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110
None -- -- 39.6 41.6 45.1 47.1 50 50 50 60
2TP04520925 9.0 21.7 39.6 41.6 45.1 47.1 50 50 50 60
2TP04521825 18.0 43.3 61.9 64.4 68.8 71.3 70 70 70 80
2TP04522425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90
2TP04523625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125
None -- -- 20.7 21.7 22.9 23.9 25 25 25 30
2TP04520946 9 11.3 20.7 21.7 22.9 23.9 25 25 25 30
2TP04521846 18 22.6 30.9 32.2 33.7 34.9 35 35 35 35
2TP04522446 24 30.1 40 41.2 42.7 44 40 45 45 45
2TP04523646 34 42.7 55 56.2 57.7 59 60 60 60 60
None -- -- 15.8 17 17.6 18.8 20 20 20 20
2TP04520958 9 9.0 15.8 17 17.6 18.8 20 20 20 20
2TP04521858 18 18.1 24.7 26.2 26.9 28.4 25 30 30 30
2TP04522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40
2TP04523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50
*
Electric Heater
Model No.
Actual
KW
Pwr
Conv
Outlet
5.4 44.0 0.6 2.4 3.6 1.8 0.0
Maximum HACR breaker of the same AMP size is applicable.
13.5 110.0 1.5 6.2 8.2 5.5 0.0230
460
575
7.1 54.0 0.8 3.1 4.1 2.2
208
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
13.5 110.0 1.5 6.2 8.2
FLA
5.5 0.0
0.0
Heater
Amps
Min. Circuit
Ampacity
(Amps)
Pwr
Exh
MotorVoltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 49.6 51.6 55.1 57.1 60 60 60 70
2TP04520925 6.8 18.9 49.6 51.6 55.1 57.1 60 60 60 70
2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80
2TP04522425 18.0 50.0 82.7 85.2 89.6 92.1 90 90 90 100
2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125
None -- -- 49.6 51.6 55.1 57.1 60 60 60 70
2TP04520925 9.0 21.7 49.6 51.6 55.1 57.1 60 60 60 70
2TP04521825 18.0 43.3 74.4 76.9 81.3 83.8 80 80 90 90
2TP04522425 24.0 57.7 92.4 94.9 99.3 101.8 100 100 100 110
2TP04523625 34.0 81.8 122.5 125.0 129.4 131.9 125 125 150 150
None -- -- 25.7 26.7 27.9 28.9 30 30 30 35
2TP04520946 9 11.3 25.7 26.7 27.9 28.9 30 30 30 35
2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45
2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60
2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70
None -- -- 19.8 21 21.6 22.8 25 25 25 25
2TP04520958 9 9.0 19.8 21 21.6 22.8 25 25 25 25
2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35
2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45
2TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60
*
4.1 2.2 5.0
5.4 44.0 0.6 2.4 3.6 1.8 4.0
7.1 54.0 0.8 3.1
8.2 5.5 10.0
5.5 10.0
Actual
KW
13.5 110.0 1.5 6.2
460
Maximum HACR breaker of the same AMP size is applicable.
575
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
MCA
w/Power
Exhaust
(Amps)
Heater
Amps
Min. Circuit
Ampacity
(Amps)Electric Heater
Model No.
208
230
OD Fan
Motors
Supply
Blower
Motor FLA
13.5 110.0 1.5 6.2 8.2
Voltage
Compressors
Pwr
Exh
Motor
Pwr
Conv
Outlet
FLA FLA
035-17291-001-A-0903
Unitary Products Group 11
TABLE 6: ELECTRICAL DATA - DM/DL (8-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 7: ELECTRICAL DATA - DM/DL (8-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04520925 6.8 18.9 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04520925 9.0 21.7 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125
None -- -- 26 27.2 28.2 29.4 30 35 35 35
2TP04520946 9 11.3 26 27.2 28.2 29.4 30 35 35 35
2TP04521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04520958 9 9.0 20.6 21.1 22.4 22.9 25 25 25 25
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
1.6 4.1 5.3 2.2 0.0
3.5 8.2 10.916.0 137.0
8.3 69.0
8.2 10.9 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
6.4 58.0 1.3 3.6 4.1 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 16.0 137.0 3.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04520925 6.8 18.9 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04520925 9.0 21.7 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150
None -- -- 31 32.2 33.2 34.4 35 40 40 40
2TP04520946 9 11.3 31 32.2 33.2 34.4 35 40 40 40
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04520958 9 9.0 24.6 25.1 26.4 26.9 30 30 30 30
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
*
2.2 5.0
6.4 58.0 1.3 3.6 4.1 1.8 4.0
8.3
3.5 8.2 10.9 5.5 10.0
3.5 8.2 10.9 5.5 10.0
69.0 1.6 4.1 5.3460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
16.0 137.0
16.0 137.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
12 Unitary Products Group
TABLE 8: ELECTRICAL DATA - DM/DL (10 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 9: ELECTRICAL DATA - DM/DL (10 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.9 54.6 57.4 60.1 60 70 70 70
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
2TP04525425 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175
None -- -- 51.9 54.6 57.4 60.1 60 70 70 70
2TP04521825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125
2TP04525425 54.0 129.9 140.2 143.5 147.0 150.4 150 175 175 175
None -- -- 33.2 34.4 35.4 36.6 40 45 45 45
2TP04521846 18 22.6 33.2 34.4 35.4 36.6 40 45 45 45
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
2TP04525446 54 67.8 70.1 71.6 72.8 74.3 80 80 80 80
None -- -- 22.2 22.7 24 24.5 25 25 30 30
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
2TP04525458 54 54.2 56.5 57.1 58.7 59.3 70 70 70 70
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
1.6 4.1 5.3 2.2 0.0
3.5 8.2 10.916.3 150.0
11.5 75.0
8.2 10.9 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
7.1 62.0 1.3 3.6 4.1 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 16.3 150.0 3.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.9 64.6 67.4 70.1 70 80 80 80
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
2TP04525425 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175
None -- -- 61.9 64.6 67.4 70.1 70 80 80 80
2TP04521825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150
2TP04525425 54.0 129.9 152.7 156.0 159.5 162.9 175 175 175 175
None -- -- 38.2 39.4 40.4 41.6 45 50 50 50
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 45 50 50 50
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
2TP04525446 54 67.8 76.3 77.8 79.1 80.6 90 90 90 90
None -- -- 26.2 26.7 28 28.5 30 30 35 35
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
2TP04525458 54 54.2 61.5 62.1 63.7 64.3 70 70 70 70
*
2.2 5.0
7.1 62.0 1.3 3.6 4.1 1.8 4.0
11.5
3.5 8.2 10.9 5.5 10.0
3.5 8.2 10.9 5.5 10.0
75.0 1.6 4.1 5.3460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
16.3 150.0
16.3 150.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
Unitary Products Group 13
TABLE 10: ELECTRICAL DATA - DM/DL (12-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET60 HTZ.
TABLE 11: ELECTRICAL DATA - DM/DL (12-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET60 HTZ.
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 67.0 72.2 72.5 77.7 80 90 90 90
2TP04521825 13.5 37.5 67.0 72.2 72.5 77.7 80 90 90 90
2TP04522425 18.0 50.0 76.1 82.6 83.0 89.5 80 90 90 90
2TP04523625 25.5 70.8 102.1 108.6 109.0 115.5 110 110 110 125
2TP04525425 40.6 112.7 154.5 161.0 161.4 167.9 175 175 175 175
None -- -- 67.0 72.2 72.5 77.7 80 90 90 90
2TP04521825 18.0 43.3 67.8 74.3 74.6 81.1 80 90 90 90
2TP04522425 24.0 57.7 85.8 92.3 92.7 99.2 90 100 100 100
2TP04523625 34.0 81.8 115.9 122.4 122.7 129.2 125 125 125 150
2TP04525425 54.0 129.9 143.5 150.0 150.4 156.9 175 175 175 175
None -- -- 30.1 32.9 32.3 35.1 35 40 40 40
2TP04521846 18 22.6 33.7 37.2 36.4 39.9 35 40 40 40
2TP04522446 24 30.1 42.7 46.2 45.5 49 45 50 50 50
2TP04523646 34 42.7 57.7 61.2 60.5 64 60 70 70 70
2TP04525446 54 67.8 71.6 75.1 74.3 77.8 80 90 80 90
None -- -- 27 28.9 28.8 30.7 35 35 35 35
2TP04521858 18 18.1 27 29.2 29 31.4 35 35 35 35
2TP04522458 24 24.1 34 36.4 36.2 38.6 35 40 40 40
2TP04523658 34 34.1 46 48.4 48.3 50.6 50 50 50 60
2TP04525458 54 54.2 57.1 59.5 59.3 61.7 70 70 70 70
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
1.6 5.3 8.1 2.2 0.0
3.5 10.9 16.121.8 158.0
9.6 79.0
10.9 16.1 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
9.0 65.0 1.3 4.1 6.0 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 21.8 158.0 3.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 77.0 82.2 82.5 87.7 90 100 100 100
2TP04521825 13.5 37.5 77.0 82.2 82.5 87.7 90 100 100 100
2TP04522425 18.0 50.0 88.6 95.1 95.5 102.0 90 100 100 110
2TP04523625 25.5 70.8 114.6 121.1 121.5 128.0 125 125 125 150
2TP04525425 40.6 112.7 167.0 173.5 173.9 180.4 175 175 175 200
None -- -- 77.0 82.2 82.5 87.7 90 100 100 100
2TP04521825 18.0 43.3 80.3 86.8 87.1 93.6 90 100 100 100
2TP04522425 24.0 57.7 98.3 104.8 105.2 111.7 100 110 110 125
2TP04523625 34.0 81.8 128.4 134.9 135.2 141.7 150 150 150 150
2TP04525425 54.0 129.9 156.0 162.5 162.9 169.4 175 175 175 175
None -- -- 35.1 37.9 37.3 40.1 40 45 45 45
2TP04521846 18 22.6 39.9 43.4 42.7 46.2 40 45 45 50
2TP04522446 24 30.1 49 52.5 51.7 55.2 50 60 60 60
2TP04523646 34 42.7 64 67.5 66.7 70.2 70 70 70 80
2TP04525446 54 67.8 77.8 81.3 80.6 84.1 90 90 90 90
None -- -- 31 32.9 32.8 34.7 35 40 40 40
2TP04521858 18 18.1 31.8 34.2 34 36.4 35 40 40 40
2TP04522458 24 24.1 39 41.4 41.2 43.6 40 45 45 45
2TP04523658 34 34.1 51 53.4 53.3 55.6 60 60 60 60
2TP04525458 54 54.2 62.1 64.5 64.3 66.7 70 70 70 70
*
2.2 5.0
9.0 65.0 1.3 4.1 6.0 1.8 4.0
9.6
3.5 10.9 16.1 5.5 10.0
3.5 10.9 16.1 5.5 10.0
79.0 1.6 5.3 8.1460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
21.8 158.0
21.8 158.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
14 Unitary Products Group
TABLE 12: ELECTRICAL DATA - DF/DS (6-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 13: ELECTRICAL DATA - DF/DS (6-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 33.1 35.1 38.6 40.6 40 45 45 50
2TP04520925 6.8 18.9 33.1 35.1 38.6 40.7 40 45 45 50
2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70
2TP04522425 18.0 50.0 70.2 72.7 77.1 79.6 80 80 80 80
2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110
None -- -- 33.1 35.1 38.6 40.6 40 45 45 50
2TP04520925 9.0 21.7 34.8 37.3 41.7 44.2 40 45 45 50
2TP04521825 18.0 43.3 61.9 64.4 68.8 71.3 70 70 70 80
2TP04522425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90
2TP04523625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125
None -- -- 16.4 17.4 18.6 19.6 20 20 20 20
2TP04520946 9 11.3 17.4 18.7 20.2 21.4 20 20 25 25
2TP04521846 18 22.6 30.9 32.2 33.7 34.9 35 35 35 35
2TP04522446 24 30.1 40 41.2 42.7 44 40 45 45 45
2TP04523646 34 42.7 55 56.2 57.7 59 60 60 60 60
None -- -- 12.8 14 14.6 15.8 15 15 15 20
2TP04520958 9 9.0 13.8 15.3 16.1 17.6 15 20 20 20
2TP04521858 18 18.1 24.7 26.2 26.9 28.4 25 30 30 30
2TP04522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40
2TP04523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
0.8 3.1 4.1 2.2 0.0
1.5 6.2 8.210.6 78.0
5.2 40.0
6.2 8.2 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
4.1 32.0 0.6 2.4 3.6 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 10.6 78.0 1.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 43.1 45.1 48.6 50.6 50 50 50 60
2TP04520925 6.8 18.9 43.8 46.3 50.7 53.2 50 50 60 60
2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80
2TP04522425 18.0 50.0 82.7 85.2 89.6 92.1 90 90 90 100
2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125
None -- -- 43.1 45.1 48.6 50.6 50 50 50 60
2TP04520925 9.0 21.7 47.3 49.8 54.2 56.7 50 50 60 60
2TP04521825 18.0 43.3 74.4 76.9 81.3 83.8 80 80 90 90
2TP04522425 24.0 57.7 92.4 94.9 99.3 101.8 100 100 100 110
2TP04523625 34.0 81.8 122.5 125.0 129.4 131.9 125 125 150 150
None -- -- 21.4 22.4 23.6 24.6 25 25 25 25
2TP04520946 9 11.3 23.7 24.9 26.4 27.7 25 25 30 30
2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45
2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60
2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70
None -- -- 16.8 18 18.6 19.8 20 20 20 20
2TP04520958 9 9.0 18.8 20.3 21.1 22.6 20 25 25 25
2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35
2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45
2TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60
*
2.2 5.0
4.1 32.0 0.6 2.4 3.6 1.8 4.0
5.2
1.5 6.2 8.2 5.5 10.0
1.5 6.2 8.2 5.5 10.0
40.0 0.8 3.1 4.1460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
10.6 78.0
10.6 78.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
Unitary Products Group 15
TABLE 14: ELECTRICAL DATA - DF/DS (7-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 15: ELECTRICAL DATA - DF/DS (7-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 6.8 18.9 38.0 40.0 43.5 45.5 50 50 50 50
2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70
2TP04522425 18.0 50.0 70.2 72.7 77.1 79.6 80 80 80 80
2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 9.0 21.7 38.0 40.0 43.5 45.5 50 50 50 50
2TP04521825 18.0 43.3 61.9 64.4 68.8 71.3 70 70 70 80
2TP04522425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90
2TP04523625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125
None -- -- 20.7 21.7 22.9 23.9 25 25 25 30
2TP04520946 9 11.3 20.7 21.7 22.9 23.9 25 25 25 30
2TP04521846 18 22.6 30.9 32.2 33.7 34.9 35 35 35 35
2TP04522446 24 30.1 40 41.2 42.7 44 40 45 45 45
2TP04523646 34 42.7 55 56.2 57.7 59 60 60 60 60
None -- -- 15.1 16.3 16.9 18.1 20 20 20 20
2TP04520958 9 9.0 15.1 16.3 16.9 18.1 20 20 20 20
2TP04521858 18 18.1 24.7 26.2 26.9 28.4 25 30 30 30
2TP04522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40
2TP04523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
0.8 3.1 4.1 2.2 0.0
1.5 6.2 8.212.8 110.0
7.1 54.0
6.2 8.2 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
5.1 44.0 0.6 2.4 3.6 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 12.8 110.0 1.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 6.8 18.9 48.0 50.0 53.5 55.5 60 60 60 60
2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80
2TP04522425 18.0 50.0 82.7 85.2 89.6 92.1 90 90 90 100
2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 9.0 21.7 48.0 50.0 54.2 56.7 60 60 60 60
2TP04521825 18.0 43.3 74.4 76.9 81.3 83.8 80 80 90 90
2TP04522425 24.0 57.7 92.4 94.9 99.3 101.8 100 100 100 110
2TP04523625 34.0 81.8 122.5 125.0 129.4 131.9 125 125 150 150
None -- -- 25.7 26.7 27.9 28.9 30 30 30 35
2TP04520946 9 11.3 25.7 26.7 27.9 28.9 30 30 30 35
2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45
2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60
2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70
None -- -- 19.1 20.3 20.9 22.1 20 25 25 25
2TP04520958 9 9.0 19.1 20.3 21.1 22.6 20 25 25 25
2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35
2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45
2TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60
*
2.2 5.0
5.1 44.0 0.6 2.4 3.6 1.8 4.0
7.1
1.5 6.2 8.2 5.5 10.0
1.5 6.2 8.2 5.5 10.0
54.0 0.8 3.1 4.1460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
12.8 110.0
12.8 110.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
Subject to change without notice. Printed in U.S.A. 035-17291-001-A-0903Copyright © by Unitary Products Group 2003. All rights reserved. Supersedes: 035-17291-000 REV.B (0301)
Unitary 5005 NormanProducts York OKGroup Drive 73069
TABLE 16: ELECTRICAL DATA - DF/DS (8-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 17: ELECTRICAL DATA - DF/DS (8-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 41.6 44.3 47.1 49.8 50 50 60 60
2TP04520925 6.8 18.9 41.6 44.3 47.1 49.8 50 50 60 60
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
None -- -- 41.6 44.3 47.1 49.8 50 50 60 60
2TP04520925 9.0 21.7 41.6 44.3 47.1 49.8 50 50 60 60
2TP04521825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125
None -- -- 21.7 22.9 23.9 25.1 25 25 30 30
2TP04520946 9 11.3 21.7 22.9 23.9 25.1 25 25 30 30
2TP04521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
None -- -- 17 17.5 18.8 19.3 20 20 20 20
2TP04520958 9 9.0 17 17.5 18.8 19.3 20 20 20 20
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
0.8 4.1 5.3 2.2 0.0
1.5 8.2 10.913.5 110.0
7.1 54.0
8.2 10.9 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
5.4 44.0 0.6 3.6 4.1 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 13.5 110.0 1.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.6 54.3 57.1 59.8 60 60 70 70
2TP04520925 6.8 18.9 51.6 54.3 57.1 59.8 60 60 70 70
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
None -- -- 51.6 54.3 57.1 59.8 60 60 70 70
2TP04520925 9.0 21.7 51.6 54.3 57.1 60.1 60 60 70 70
2TP04521825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150
None -- -- 26.7 27.9 28.9 30.1 30 30 35 35
2TP04520946 9 11.3 26.7 27.9 28.9 30.1 30 30 35 35
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
None -- -- 21 21.5 22.8 23.3 25 25 25 25
2TP04520958 9 9.0 21 21.5 22.8 23.3 25 25 25 25
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
*
2.2 5.0
5.4 44.0 0.6 3.6 4.1 1.8 4.0
7.1
1.5 8.2 10.9 5.5 10.0
1.5 8.2 10.9 5.5 10.0
54.0 0.8 4.1 5.3460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
13.5 110.0
13.5 110.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
Unitary Products Group 17
TABLE 18: ELECTRICAL DATA - DF/DS (10 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 19: ELECTRICAL DATA - DF/DS (10 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
2TP04525425 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125
2TP04525425 54.0 129.9 140.2 143.5 147.0 150.4 150 175 175 175
None -- -- 26 27.2 28.2 29.4 30 35 35 35
2TP04521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
2TP04525446 54 67.8 70.1 71.6 72.8 74.3 80 80 80 80
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
2TP04525458 54 54.2 56.5 57.1 58.7 59.3 70 70 70 70
*
5.5 0.0
Pwr
Conv
Outlet
6.4 58.0 1.3 3.6 4.1 1.8 0.0
0.0
0.0
5.5
2.2
3.5 8.2
Maximum HACR breaker of the same AMP size is applicable.
8.3 69.0 1.6 4.1 5.3
230
460
575
10.916.0 137.0 3.5 8.2
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Electric Heater
Model No.
Actual
KW
Min. Circuit
Ampacity
(Amps)Heater
Amps
FLA
Voltage
208
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
10.916.0 137.0
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
2TP04525425 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150
2TP04525425 54.0 129.9 152.7 156.0 159.5 162.9 175 175 175 175
None -- -- 31 32.2 33.2 34.4 35 40 40 40
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
2TP04525446 54 67.8 76.3 77.8 79.1 80.6 90 90 90 90
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
2TP04525458 54 54.2 61.5 62.1 63.7 64.3 70 70 70 70
*
4.1 1.8 4.06.4 58.0 1.3 3.6
8.2 10.9 5.5 10.0
10.0
FLA
5.5
16.0 137.0 3.5230
460
575
Maximum HACR breaker of the same AMP size is applicable.
8.3 69.0 1.6 4.1 5.3 2.2 5.0
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
208 16.0 137.0 3.5 10.98.2
CompressorsOD Fan
Motors Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Supply
Blower
Motor FLA
Pwr
Exh
MotorVoltage
Pwr
Conv
OutletElectric Heater
Model No.
Actual
KW
FLA
035-17291-001-A-0903
18 Unitary Products Group
TABLE 20: ELECTRICAL DATA - DH/DU (6-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 21: ELECTRICAL DATA - DH/DU (6-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 34.4 36.4 39.9 41.9 45 45 50 50
2TP04520925 6.8 18.9 34.4 36.4 39.9 41.9 45 45 50 50
2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70
2TP04522425 18.0 50.0 70.2 72.7 77.1 79.6 80 80 80 80
2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110
None -- -- 34.4 36.4 39.9 41.9 45 45 50 50
2TP04520925 9.0 21.7 34.8 37.3 41.7 44.2 45 45 50 50
2TP04521825 18.0 43.3 61.9 64.4 68.8 71.3 70 70 70 80
2TP04522425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90
2TP04523625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125
None -- -- 18.4 19.4 20.6 21.6 20 25 25 25
2TP04520946 9 11.3 18.4 19.4 20.6 21.6 20 25 25 25
2TP04521846 18 22.6 30.9 32.2 33.7 34.9 35 35 35 35
2TP04522446 24 30.1 40 41.2 42.7 44 40 45 45 45
2TP04523646 34 42.7 55 56.2 57.7 59 60 60 60 60
None -- -- 14.4 15.6 16.2 17.4 15 20 20 20
2TP04520958 9 9.0 14.4 15.6 16.2 17.6 15 20 20 20
2TP04521858 18 18.1 24.7 26.2 26.9 28.4 25 30 30 30
2TP04522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40
2TP04523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
0.8 3.1 4.1 2.2 0.0
1.5 6.2 8.211.2 110.0
6.1 54.0
6.2 8.2 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
4.8 44.0 0.6 2.4 3.6 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 11.2 110.0 1.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 44.4 46.4 49.9 51.9 50 50 60 60
2TP04520925 6.8 18.9 44.4 46.4 50.7 53.2 50 50 60 60
2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80
2TP04522425 18.0 50.0 82.7 85.2 89.6 92.1 90 90 90 100
2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125
None -- -- 44.4 46.4 49.9 51.9 50 50 60 60
2TP04520925 9.0 21.7 47.3 49.8 54.2 56.7 50 50 60 60
2TP04521825 18.0 43.3 74.4 76.9 81.3 83.8 80 80 90 90
2TP04522425 24.0 57.7 92.4 94.9 99.3 101.8 100 100 100 110
2TP04523625 34.0 81.8 122.5 125.0 129.4 131.9 125 125 150 150
None -- -- 23.4 24.4 25.6 26.6 25 30 30 30
2TP04520946 9 11.3 23.7 24.9 26.4 27.7 25 30 30 30
2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45
2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60
2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70
None -- -- 18.4 19.6 20.2 21.4 20 20 25 25
2TP04520958 9 9.0 18.8 20.3 21.1 22.6 20 25 25 25
2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35
2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 452TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60
*
2.2 5.0
4.8 44.0 0.6 2.4 3.6 1.8 4.0
6.1
1.5 6.2 8.2 5.5 10.0
1.5 6.2 8.2 5.5 10.0
54.0 0.8 3.1 4.1460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
11.2 110.0
11.2 110.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
Unitary Products Group 19
TABLE 22: ELECTRICAL DATA - DH/DU (7-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 23: ELECTRICAL DATA - DH/DU (7-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 40.9 42.9 46.4 48.4 50 50 60 60
2TP04520925 6.8 18.9 40.9 42.9 46.4 48.4 50 50 60 60
2TP04521825 13.5 37.5 54.6 57.1 61.5 64.0 60 60 70 70
2TP04522425 18.0 50.0 70.2 72.7 77.1 79.6 80 80 80 80
2TP04523625 25.5 70.8 96.2 98.7 103.1 105.6 100 100 110 110
None -- -- 40.9 42.9 46.4 48.4 50 50 60 60
2TP04520925 9.0 21.7 40.9 42.9 46.4 48.4 50 50 60 60
2TP04521825 18.0 43.3 61.9 64.4 68.8 71.3 70 70 70 80
2TP04522425 24.0 57.7 79.9 82.4 86.8 89.3 80 90 90 90
2TP04523625 34.0 81.8 110.0 112.5 116.9 119.4 110 125 125 125
None -- -- 20.7 21.7 22.9 23.9 25 25 25 30
2TP04520946 9 11.3 20.7 21.7 22.9 23.9 25 25 25 30
2TP04521846 18 22.6 30.9 32.2 33.7 34.9 35 35 35 35
2TP04522446 24 30.1 40 41.2 42.7 44 40 45 45 45
2TP04523646 34 42.7 55 56.2 57.7 59 60 60 60 60
None -- -- 16.7 17.9 18.5 19.7 20 20 20 25
2TP04520958 9 9.0 16.7 17.9 18.5 19.7 20 20 20 25
2TP04521858 18 18.1 24.7 26.2 26.9 28.4 25 30 30 30
2TP04522458 24 24.1 31.9 33.4 34.1 35.6 35 35 35 40
2TP04523658 34 34.1 43.9 45.4 46.1 47.6 45 50 50 50
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
0.8 3.1 4.1 2.2 0.0
1.5 6.2 8.214.1 110.0
7.1 54.0
6.2 8.2 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
5.8 44.0 0.6 2.4 3.6 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 14.1 110.0 1.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 50.9 52.9 56.4 58.4 60 60 70 70
2TP04520925 6.8 18.9 50.9 52.9 56.4 58.4 60 60 70 70
2TP04521825 13.5 37.5 67.1 69.6 74.0 76.5 70 70 80 80
2TP04522425 18.0 50.0 82.7 85.2 89.6 92.1 90 90 90 100
2TP04523625 25.5 70.8 108.7 111.2 115.6 118.1 110 125 125 125
None -- -- 50.9 52.9 56.4 58.4 60 60 70 70
2TP04520925 9.0 21.7 50.9 52.9 56.4 58.4 60 60 70 70
2TP04521825 18.0 43.3 74.4 76.9 81.3 83.8 80 80 90 90
2TP04522425 24.0 57.7 92.4 94.9 99.3 101.8 100 100 100 110
2TP04523625 34.0 81.8 122.5 125.0 129.4 131.9 125 125 150 150
None -- -- 25.7 26.7 27.9 28.9 30 30 30 35
2TP04520946 9 11.3 25.7 26.7 27.9 28.9 30 30 30 35
2TP04521846 18 22.6 37.2 38.4 39.9 41.2 40 40 40 45
2TP04522446 24 30.1 46.2 47.5 49 50.2 50 50 50 60
2TP04523646 34 42.7 61.2 62.5 64 65.2 70 70 70 70
None -- -- 20.7 21.9 22.5 23.7 25 25 25 25
2TP04520958 9 9.0 20.7 21.9 22.5 23.7 25 25 25 25
2TP04521858 18 18.1 29.7 31.2 31.9 33.4 30 35 35 35
2TP04522458 24 24.1 36.9 38.4 39.1 40.6 40 40 40 45
2TP04523658 34 34.1 48.9 50.4 51.1 52.6 50 60 60 60
*
2.2 5.0
5.8 44.0 0.6 2.4 3.6 1.8 4.0
7.1
1.5 6.2 8.2 5.5 10.0
1.5 6.2 8.2 5.5 10.0
54.0 0.8 3.1 4.1460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
14.1 110.0
14.1 110.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
20 Unitary Products Group
TABLE 24: ELECTRICAL DATA - DH/DU (8-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 25: ELECTRICAL DATA - DH/DU (8-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 40.0 42.7 45.5 48.2 50 50 50 60
2TP04520925 6.8 18.9 40.0 42.7 45.5 48.2 50 50 50 60
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
None -- -- 40.0 42.7 45.5 48.2 50 50 50 60
2TP04520925 9.0 21.7 40.0 42.7 45.5 48.2 50 50 50 60
2TP04521825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125
None -- -- 23 24.2 25.2 26.4 30 30 30 30
2TP04520946 9 11.3 23 24.2 25.2 26.4 30 30 30 30
2TP04521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
None -- -- 18.5 19 20.3 20.8 20 25 25 25
2TP04520958 9 9.0 18.5 19 20.3 20.8 20 25 25 25
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
0.8 4.1 5.3 2.2 0.0
1.5 8.2 10.912.8 130.0
7.7 64.0
8.2 10.9 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
6.1 52.0 0.6 3.6 4.1 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 12.8 130.0 1.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 50.0 52.7 55.5 58.2 60 60 60 70
2TP04520925 6.8 18.9 50.0 52.7 55.5 58.2 60 60 60 70
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
None -- -- 50.0 52.7 55.5 58.2 60 60 60 70
2TP04520925 9.0 21.7 50.0 53.2 56.7 60.1 60 60 60 70
2TP04521825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150
None -- -- 28 29.2 30.2 31.4 35 35 35 35
2TP04520946 9 11.3 28 29.2 30.2 31.4 35 35 35 35
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
None -- -- 22.5 23 24.3 24.8 25 25 30 30
2TP04520958 9 9.0 22.5 23 24.3 24.8 25 25 30 30
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
*
2.2 5.0
6.1 52.0 0.6 3.6 4.1 1.8 4.0
7.7
1.5 8.2 10.9 5.5 10.0
1.5 8.2 10.9 5.5 10.0
64.0 0.8 4.1 5.3460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
12.8 130.0
12.8 130.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
Unitary Products Group 21
TABLE 26: ELECTRICAL DATA - DH/DU (10 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 27: ELECTRICAL DATA - DH/DU (10 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 13.5 37.5 57.1 60.5 64.0 67.3 60 70 70 70
2TP04522425 18.0 50.0 72.7 76.1 79.6 83.0 80 80 80 90
2TP04523625 25.5 70.8 98.7 102.1 105.6 109.0 100 110 110 110
2TP04525425 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 18.0 43.3 64.4 67.8 71.3 74.6 70 70 80 80
2TP04522425 24.0 57.7 82.4 85.8 89.3 92.7 90 90 90 100
2TP04523625 34.0 81.8 112.5 115.9 119.4 122.7 125 125 125 125
2TP04525425 54.0 129.9 140.2 143.5 147.0 150.4 150 175 175 175
None -- -- 26 27.2 28.2 29.4 30 35 35 35
2TP04521846 18 22.6 32.2 33.7 34.9 36.4 35 35 35 40
2TP04522446 24 30.1 41.2 42.7 44 45.5 45 45 45 50
2TP04523646 34 42.7 56.2 57.7 59 60.5 60 60 60 70
2TP04525446 54 67.8 70.1 71.6 72.8 74.3 80 80 80 80
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04521858 18 18.1 26.2 26.8 28.4 29 30 30 30 30
2TP04522458 24 24.1 33.4 34 35.6 36.2 35 35 40 40
2TP04523658 34 34.1 45.4 46 47.6 48.3 50 50 50 50
2TP04525458 54 54.2 56.5 57.1 58.7 59.3 70 70 70 70
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
1.6 4.1 5.3 2.2 0.0
3.5 8.2 10.916.0 137.0
8.3 69.0
8.2 10.9 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
6.4 58.0 1.3 3.6 4.1 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 16.0 137.0 3.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 13.5 37.5 69.6 73.0 76.5 79.8 70 80 80 80
2TP04522425 18.0 50.0 85.2 88.6 92.1 95.5 90 90 100 100
2TP04523625 25.5 70.8 111.2 114.6 118.1 121.5 125 125 125 125
2TP04525425 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 18.0 43.3 76.9 80.3 83.8 87.1 80 90 90 90
2TP04522425 24.0 57.7 94.9 98.3 101.8 105.2 100 100 110 110
2TP04523625 34.0 81.8 125.0 128.4 131.9 135.2 125 150 150 150
2TP04525425 54.0 129.9 152.7 156.0 159.5 162.9 175 175 175 175
None -- -- 31 32.2 33.2 34.4 35 40 40 40
2TP04521846 18 22.6 38.4 39.9 41.2 42.7 40 40 45 45
2TP04522446 24 30.1 47.5 49 50.2 51.7 50 50 60 60
2TP04523646 34 42.7 62.5 64 65.2 66.7 70 70 70 70
2TP04525446 54 67.8 76.3 77.8 79.1 80.6 90 90 90 90
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04521858 18 18.1 31.2 31.8 33.4 34 35 35 35 35
2TP04522458 24 24.1 38.4 39 40.6 41.2 40 40 45 45
2TP04523658 34 34.1 50.4 51 52.6 53.3 60 60 60 60
2TP04525458 54 54.2 61.5 62.1 63.7 64.3 70 70 70 70
*
2.2 5.0
6.4 58.0 1.3 3.6 4.1 1.8 4.0
8.3
3.5 8.2 10.9 5.5 10.0
3.5 8.2 10.9 5.5 10.0
69.0 1.6 4.1 5.3460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
16.0 137.0
16.0 137.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
22 Unitary Products Group
TABLE 28: ELECTRICAL DATA - DH/DU (12-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET60 HTZ.
TABLE 29: ELECTRICAL DATA - DH/DU (12-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 60.4 65.6 65.9 71.1 70 80 80 90
2TP04521825 13.5 37.5 60.5 67.0 67.3 73.8 70 80 80 90
2TP04522425 18.0 50.0 76.1 82.6 83.0 89.5 80 90 90 90
2TP04523625 25.5 70.8 102.1 108.6 109.0 115.5 110 110 110 125
2TP04525425 40.6 112.7 154.5 161.0 161.4 167.9 175 175 175 175
None -- -- 60.4 65.6 65.9 71.1 70 80 80 90
2TP04521825 18.0 43.3 67.8 74.3 74.6 81.1 70 80 80 90
2TP04522425 24.0 57.7 85.8 92.3 92.7 99.2 90 100 100 100
2TP04523625 34.0 81.8 115.9 122.4 122.7 129.2 125 125 125 150
2TP04525425 54.0 129.9 143.5 150.0 150.4 156.9 175 175 175 175
None -- -- 29.9 32.7 32.1 34.9 35 40 40 40
2TP04521846 18 22.6 33.7 37.2 36.4 39.9 35 40 40 40
2TP04522446 24 30.1 42.7 46.2 45.5 49 45 50 50 50
2TP04523646 34 42.7 57.7 61.2 60.5 64 60 70 70 70
2TP04525446 54 67.8 71.6 75.1 74.3 77.8 80 90 80 90
None -- -- 23.8 25.7 25.6 27.5 30 30 30 35
2TP04521858 18 18.1 26.8 29.2 29 31.4 30 30 30 35
2TP04522458 24 24.1 34 36.4 36.2 38.6 35 40 40 40
2TP04523658 34 34.1 46 48.4 48.3 50.6 50 50 50 60
2TP04525458 54 54.2 57.1 59.5 59.3 61.7 70 70 70 70
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
1.6 5.3 8.1 2.2 0.0
3.5 10.9 16.118.9 146.0
9.5 73.0
10.9 16.1 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
7.6 58.4 1.3 4.1 6.0 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 18.9 146.0 3.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 70.4 75.6 75.9 81.1 80 90 90 100
2TP04521825 13.5 37.5 73.0 79.5 79.8 86.3 80 90 90 100
2TP04522425 18.0 50.0 88.6 95.1 95.5 102.0 90 100 100 110
2TP04523625 25.5 70.8 114.6 121.1 121.5 128.0 125 125 125 150
2TP04525425 40.6 112.7 167.0 173.5 173.9 180.4 175 175 175 200
None -- -- 70.4 75.6 75.9 81.1 80 90 90 100
2TP04521825 18.0 43.3 80.3 86.8 87.1 93.6 90 90 90 100
2TP04522425 24.0 57.7 98.3 104.8 105.2 111.7 100 110 110 125
2TP04523625 34.0 81.8 128.4 134.9 135.2 141.7 150 150 150 150
2TP04525425 54.0 129.9 156.0 162.5 162.9 169.4 175 175 175 175
None -- -- 34.9 37.7 37.1 39.9 40 45 45 45
2TP04521846 18 22.6 39.9 43.4 42.7 46.2 40 45 45 50
2TP04522446 24 30.1 49 52.5 51.7 55.2 50 60 60 60
2TP04523646 34 42.7 64 67.5 66.7 70.2 70 70 70 80
2TP04525446 54 67.8 77.8 81.3 80.6 84.1 90 90 90 90
None -- -- 27.8 29.7 29.6 31.5 35 35 35 35
2TP04521858 18 18.1 31.8 34.2 34 36.4 35 35 35 40
2TP04522458 24 24.1 39 41.4 41.2 43.6 40 45 45 45
2TP04523658 34 34.1 51 53.4 53.3 55.6 60 60 60 60
2TP04525458 54 54.2 62.1 64.5 64.3 66.7 70 70 70 70
*
2.2 5.0
7.6 58.4 1.3 4.1 6.0 1.8 4.0
9.5
3.5 10.9 16.1 5.5 10.0
3.5 10.9 16.1 5.5 10.0
73.0 1.6 5.3 8.1460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
18.9 146.0
18.9 146.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
Unitary Products Group 23
TABLE 30: ELECTRICAL DATA - DJ/DW (12-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET60 HTZ.
TABLE 31: ELECTRICAL DATA - DJ/DW (12-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.9 67.1 67.4 72.6 80 80 80 90
2TP04521825 13.5 37.5 61.9 67.1 67.4 73.8 80 80 80 90
2TP04522425 18.0 50.0 76.1 82.6 83.0 89.5 80 90 90 90
2TP04523625 25.5 70.8 102.1 108.6 109.0 115.5 110 110 110 125
2TP04525425 40.6 112.7 154.5 161.0 161.4 167.9 175 175 175 175
None -- -- 61.9 67.1 67.4 72.6 80 80 80 90
2TP04521825 18.0 43.3 67.8 74.3 74.6 81.1 80 80 80 90
2TP04522425 24.0 57.7 85.8 92.3 92.7 99.2 90 100 100 100
2TP04523625 34.0 81.8 115.9 122.4 122.7 129.2 125 125 125 150
2TP04525425 54.0 129.9 143.5 150.0 150.4 156.9 175 175 175 175
None -- -- 27.4 30.2 29.6 32.4 35 35 35 40
2TP04521846 18 22.6 33.7 37.2 36.4 39.9 35 40 40 40
2TP04522446 24 30.1 42.7 46.2 45.5 49 45 50 50 50
2TP04523646 34 42.7 57.7 61.2 60.5 64 60 70 70 70
2TP04525446 54 67.8 71.6 75.1 74.3 77.8 80 90 80 90
None -- -- 21.6 23.5 23.4 25.3 25 30 30 30
2TP04521858 18 18.1 26.8 29.2 29 31.4 30 30 30 35
2TP04522458 24 24.1 34 36.4 36.2 38.6 35 40 40 40
2TP04523658 34 34.1 46 48.4 48.3 50.6 50 50 50 60
2TP04525458 54 54.2 57.1 59.5 59.3 61.7 70 70 70 70
*
Pwr
Exh
MotorElectric Heater
Model No.
Actual
KW
0.0
5.5 0.0
0.8 5.3 8.1 2.2 0.0
1.5 10.9 16.120.0 146.0
8.4 73.0
10.9 16.1 5.5 0.0
Maximum HACR breaker of the same AMP size is applicable.
6.7 60.0 0.6 4.1 6.0 1.8
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
Pwr
Conv
OutletHeater
Amps
Min. Circuit
Ampacity
(Amps)
FLA
208 20.0 146.0 1.5
230
460
575
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 71.9 77.1 77.4 82.6 90 90 90 100
2TP04521825 13.5 37.5 73.0 79.5 79.8 86.3 90 90 90 100
2TP04522425 18.0 50.0 88.6 95.1 95.5 102.0 90 100 100 110
2TP04523625 25.5 70.8 114.6 121.1 121.5 128.0 125 125 125 150
2TP04525425 40.6 112.7 167.0 173.5 173.9 180.4 175 175 175 200
None -- -- 71.9 77.1 77.4 82.6 90 90 90 100
2TP04521825 18.0 43.3 80.3 86.8 87.1 93.6 90 90 90 100
2TP04522425 24.0 57.7 98.3 104.8 105.2 111.7 100 110 110 125
2TP04523625 34.0 81.8 128.4 134.9 135.2 141.7 150 150 150 150
2TP04525425 54.0 129.9 156.0 162.5 162.9 169.4 175 175 175 175
None -- -- 32.4 35.2 34.6 37.4 40 40 40 45
2TP04521846 18 22.6 39.9 43.4 42.7 46.2 40 45 45 50
2TP04522446 24 30.1 49 52.5 51.7 55.2 50 60 60 60
2TP04523646 34 42.7 64 67.5 66.7 70.2 70 70 70 80
2TP04525446 54 67.8 77.8 81.3 80.6 84.1 90 90 90 90
None -- -- 25.6 27.5 27.4 29.3 30 30 30 35
2TP04521858 18 18.1 31.8 34.2 34 36.4 35 35 35 40
2TP04522458 24 24.1 39 41.4 41.2 43.6 40 45 45 45
2TP04523658 34 34.1 51 53.4 53.3 55.6 60 60 60 60
2TP04525458 54 54.2 62.1 64.5 64.3 66.7 70 70 70 70
*
2.2 5.0
6.7 60.0 0.6 4.1 6.0 1.8 4.0
8.4
1.5 10.9 16.1 5.5 10.0
1.5 10.9 16.1 5.5 10.0
73.0 0.8 5.3 8.1460
Maximum HACR breaker of the same AMP size is applicable.
575
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
Heater
Amps
FLA
208
230
CompressorsOD Fan
Motors
20.0 146.0
20.0 146.0
VoltageElectric Heater
Model No.
Actual
KW
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
Pwr
Conv
Outlet
035-17291-001-A-0903
24 Unitary Products Group
TABLE 32: ELECTRICAL DATA - DM (7-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET380 VOLT 60 HTZ.
TABLE 33: ELECTRICAL DATA - DM (7-1/2 TON) WITH POWERED CONVENIENCE OUTLET380 VOLT 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 20.7 21.7 22.9 23.9 25 25 25 30
2TP04520950 5.6 8.5 20.7 21.7 22.9 23.9 25 25 25 30
2TP04521850 11.3 17.2 25.3 26.6 28.1 29.3 30 30 30 30
2TP04522450 15 22.8 32.4 33.6 35.1 36.4 35 35 40 40
2TP04523650 21.3 32.4 44.3 45.6 47.1 48.3 45 50 50 50
* Maximum HACR breaker of the same AMP size is applicable.
0.0
Max
Fuse*
Size
(Amps)
Max Fuse*
Size
w/Power
Exhaust
3.1 4.1 2.2
Actual
KW
Heater
Amps
Min.
Circuit
Ampacity
(Amps)
380 7.1 54.0 0.8
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
FLA FLA
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 27 28 29.2 30.2 30 35 35 35
2TP04520950 5.6 8.5 27 28 29.2 30.2 30 35 35 35
2TP04521850 11.3 17.2 33.2 34.5 36 37.2 35 35 40 40
2TP04522450 15 22.8 40.2 41.5 43 44.2 45 45 45 45
2TP04523650 21.3 32.4 52.2 53.5 55 56.2 60 60 60 60
*
Electric Heater
Model No.
Actual
KWVoltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
Maximum HACR breaker of the same AMP size is applicable.
Max Fuse*
Size
w/Power
Exhaust
FLA FLA
Heater
Amps
Min.
Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Pwr
Exh
Motor
Pwr
Conv
Outlet
3.1 4.1 2.2 6.3380 7.1 54.0 0.8
035-17291-001-A-0903
Unitary Products Group 25
TABLE 34: ELECTRICAL DATA - DM (10 TON) WITHOUT POWERED CONVENIENCE OUTLET380 VOLT 60 HTZ.
TABLE 35: ELECTRICAL DATA - DM (10 TON) WITH POWERED CONVENIENCE OUTLET380 VOLT 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 33.2 34.4 35.4 36.6 40 45 45 45
2TP04521850 11.3 17.2 33.2 34.4 35.4 36.6 40 45 45 45
2TP04522450 15 22.8 33.6 35.1 36.4 37.9 40 45 45 45
2TP04523650 21.3 32.4 45.6 47.1 48.3 49.8 50 50 50 50
2TP04525450 33.8 51.4 69.3 70.8 72.1 73.6 70 80 80 80
* Maximum HACR breaker of the same AMP size is applicable.
0.0
Max
Fuse*
Size
(Amps)
Max Fuse*
Size
w/Power
Exhaust
4.1 5.3 2.2
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
380 11.5 75.0 1.6
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
FLA FLA
Voltage
CompressorsOD Fan
Motors
Supply
Blower Motor
FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 39.5 40.7 41.7 42.9 50 50 50 50
2TP04521850 11.3 17.2 39.5 40.7 41.7 42.9 50 50 50 50
2TP04522450 15 22.8 41.5 43 44.2 45.7 50 50 50 50
2TP04523650 21.3 32.4 53.5 55 56.2 57.7 60 60 60 60
2TP04525450 33.8 51.4 77.2 78.7 79.9 81.4 80 80 80 90
*
Actual
KWVoltage
CompressorsOD Fan
Motors
Supply
Blower Motor
FLA
Max Fuse*
Size
w/Power
Exhaust
FLA FLA
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Maximum HACR breaker of the same AMP size is applicable.
380 11.5 75.0 1.6 4.1 5.3 2.2 6.3
035-17291-001-A-0903
26 Unitary Products Group
TABLE 36: ELECTRICAL DATA - DM (12-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET380 VOLT 60 HTZ.
TABLE 37: ELECTRICAL DATA - DM (12-1/2 TON) WITH POWERED CONVENIENCE OUTLET380 VOLT 60 HTZ.
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 30.1 32.9 32.3 35.1 35 40 40 40
2TP04521850 11.3 17.2 30.1 32.9 32.3 35.1 35 40 40 40
2TP04522450 15 22.8 35.1 38.6 37.9 41.4 40 40 40 45
2TP04523650 21.3 32.4 47.1 50.6 49.8 53.3 50 60 50 60
2TP04525450 33.8 51.4 70.8 74.3 73.6 77.1 80 80 80 80
* Maximum HACR breaker of the same AMP size is applicable.
0.0
Max
Fuse*
Size
(Amps)
Max Fuse*
Size
w/Power
Exhaust
5.3 8.1 2.2
Actual
KW
Heater
Amps
Min.
Circuit
Ampacity
(Amps)
380 9.6 79.0 1.6
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
FLA FLA
Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 36.4 39.2 38.6 41.4 45 45 45 50
2TP04521850 11.3 17.2 36.4 39.5 38.7 42.2 45 45 45 50
2TP04522450 15 22.8 43 46.5 45.7 49.2 45 50 50 50
2TP04523650 21.3 32.4 55 58.5 57.7 61.2 60 60 60 70
2TP04525450 33.8 51.4 78.7 82.2 81.4 84.9 80 90 90 90
*
Actual
KWVoltage
CompressorsOD Fan
Motors
Supply
Blower Motor
FLA
Max Fuse*
Size
w/Power
Exhaust
FLA FLA
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Maximum HACR breaker of the same AMP size is applicable.
380 9.6 79.0 1.6 5.3 8.1 2.2 6.3
035-17291-001-A-0903
Unitary Products Group 27
TABLE 38: ELECTRICAL DATA - DM (7-1/2 TON) 50 HTZ.
Voltage*
CompressorsODFan
Motors
Supply BlowerMotor FLA
Pwr ExhMotor Electric
HeaterModel No.
ActualkW
HeaterAmps
Min. CircuitAmpacity(Amps)
MCAw/PowerExhaust(Amps)
Max FuseÜ
Size (Amps)
Max Fuse Sizew/PowerExhaust(Amps)
RLAea.
LRAea.
FLAea.
1.5 HP (1.1 kW)
2 HP (1.5 kW)
FLA1.5 HP
(1.1 kW)
2 HP (1.5 kW)
1.5 HP (1.1 kW)
2 HP (1.5 kW)
1.5 HP (1.1 kW)
2 HP (1.5 kW)
1.5 HP (1.1 kW)
2 HP (1.5 kW)
380 8.3 62 1.1 4.3 5.2 2.2
None - - 25.2 26.1 27.4 28.3 30 30 35 35
2TP04520950 5.6 8.5 25.2 26.1 27.4 28.3 30 30 35 35
2TP04521850 11.3 17.2 26.8 28.0 29.6 30.7 30 30 35 35
2TP04522450 15.0 22.8 33.9 35.0 36.6 37.7 35 35 40 40
2TP04523650 21.3 32.4 45.8 47.0 48.6 49.7 50 50 50 50
415 8.3 62 1.1 4.3 5.2 2.2
None - - 25.2 26.1 27.4 28.3 30 30 35 35
2TP04520950 6.7 9.3 25.2 26.1 27.4 28.3 30 30 35 35
2TP04521850 13.5 18.8 28.9 30.0 31.6 32.7 30 30 35 35
2TP04522450 17.9 24.9 36.5 37.6 39.3 40.4 40 40 40 40
2TP04523650 25.4 35.3 49.5 50.7 52.3 53.4 50 60 60 60
* Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.Ü Maximum HACR breaker of the same amp size is acceptable.
TABLE 39: ELECTRICAL DATA - DM (10 TON) 50 HTZ.
Voltage*
CompressorsODFan
Motors
Supply BlowerMotor FLA
Pwr ExhMotor Electric
HeaterModel No.
ActualkW
HeaterAmps
Min. CircuitAmpacity(Amps)
MCAw/PowerExhaust(Amps)
Max FuseÜ
Size (Amps)
Max Fuse Sizew/PowerExhaust(Amps)
RLAea.
LRAea.
FLAea.
2 HP (1.5 kW)
4 HP (3 kW) FLA 2 HP
(1.5 kW)4 HP
(3 kW)
2 HP (1.5 kW)
4 HP (3 kW)
2 HP (1.5 kW)
4 HP(3 kW)
2 HP (1.5 kW)
4 HP (3
kW)
380 9.6 79 1.1 5.2 7.5 2.2
None - - 29.0 31.3 31.2 33.5 35 40 40 40
2TP04521850 11.3 17.2 29.0 31.3 31.2 33.5 35 40 40 40
2TP04522450 15.0 22.8 35.0 37.9 37.7 40.6 35 40 40 45
2TP04523650 21.3 32.4 47.0 49.8 49.7 52.6 50 50 50 60
2TP04525450 33.8 51.4 70.7 73.6 73.4 76.3 80 80 80 80
415 9.6 79 1.1 5.2 7.5 2.2
None - - 29.0 31.3 31.2 33.5 35 40 40 40
2TP04521850 13.5 18.8 30.0 32.9 32.7 35.6 35 40 40 40
2TP04522450 17.9 24.9 37.6 40.5 40.4 43.3 40 45 45 45
2TP04523650 25.4 35.3 50.7 53.5 53.4 56.3 60 60 60 60
2TP04525450 40.4 56.2 76.8 79.6 79.5 82.4 80 80 80 90
* Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.Ü Maximum HACR breaker of the same amp size is acceptable.
035-17291-001-A-0903
28 Unitary Products Group
TABLE 40: ELECTRICAL DATA - DM (12-1/2 TON) 50 HTZ.
Voltage*
CompressorsODFan
Motors
Supply Air Blower
Motor FLA
Pwr ExhMotor Electric
HeaterModel No.
ActualkW
HeaterAmps
Min. Cir-cuit
Ampacity(Amps)
MCAw/PowerExhaust(Amps)
Max FuseÜ
Size (Amps)
Max Fuse Size
w/PowerExhaust(Amps)
RLAea.
LRAea.
FLAea. 4 HP (3 kW) FLA 4 HP
(3 kW)4 HP
(3 kW)4 HP
(3 kW)4 HP
(3 kW)
380 12.0 91 1.1 7.5 2.2
None - - 36.7 38.9 45 50
2TP04521850 11.3 17.2 36.7 38.9 45 50
2TP04522450 15.0 22.8 37.9 40.6 45 50
2TP04523650 21.3 32.4 49.8 52.6 50 60
2TP04525450 33.8 51.4 73.6 76.3 80 80
415 12.0 101 1.1 7.5 2.2
None - - 36.7 38.9 45 50
2TP04521850 13.5 18.8 36.7 38.9 45 50
2TP04522450 17.9 24.9 40.5 43.3 45 50
2TP04523650 25.4 35.3 53.5 56.3 60 60
2TP04525450 40.4 56.2 79.6 82.4 80 90
* Unit voltage limitations: minimum utilization 342 volts, maximum utilization 457 volts.Ü Maximum HACR breaker of the same amp size is acceptable.
035-17291-001-A-0903
Unitary Products Group 29
TABLE 41: ELECTRICAL DATA - BP/BA (6-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 42: ELECTRICAL DATA - BP/BA (6-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 33.0 35.0 38.5 40.5 45 45 50 50
2TP04520925 6.8 18.9 56.6 58.6 62.1 64.1 70 70 70 70
2TP04521825 13.5 37.5 79.9 81.9 85.4 87.4 80 90 90 90
2TP04522425 18.0 50.0 95.5 97.5 101.0 103.0 100 100 110 110
2TP04523625 25.5 70.8 121.5 123.5 127.0 129.0 125 125 150 150
None -- -- 33.0 35.0 38.5 40.5 45 45 50 50
2TP04520925 9.0 21.7 60.1 62.1 65.6 67.6 70 70 70 80
2TP04521825 18.0 43.3 87.2 89.2 92.7 94.7 90 90 100 100
2TP04522425 24.0 57.7 105.2 107.2 110.7 112.7 110 110 125 125
2TP04523625 34.0 81.8 135.3 137.3 140.8 142.8 150 150 150 150
None -- -- 16.6 17.6 18.8 19.8 25 25 25 25
2TP04520946 9 11.3 30.1 31.1 32.3 33.3 35 35 35 40
2TP04521846 18 22.6 43.6 44.6 45.8 46.8 45 45 50 50
2TP04522446 24 30.1 52.7 53.7 54.9 55.9 60 60 60 60
2TP04523646 34 42.7 67.7 68.7 69.9 70.9 70 70 70 80
None -- -- 13.1 14.3 14.9 16.1 20 20 20 20
2TP04520958 9 9.0 23.9 25.1 25.7 26.9 25 30 30 30
2TP04521858 18 18.1 34.8 36 36.6 37.8 35 40 40 40
2TP04522458 24 24.1 42 43.2 43.8 45 45 45 45 45
2TP04523658 34 34.1 54 55.2 55.8 57 60 60 60 60
*
0.0
7.6 58.4 0.6 2.4 3.6 1.8 0.0
73.0 0.8 3.1 4.1
5.56.2 8.2
2.2
0.0
18.9 146.0 1.6 6.2 8.2 5.5 0.0
146.0 1.6
Maximum HACR breaker of the same AMP size is applicable.
460
575
9.5
208
230
18.9
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Max
Fuse*
Size
(Amps)Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 43.0 45.0 48.5 50.5 60 60 60 60
2TP04520925 6.8 18.9 66.6 68.6 72.1 74.1 80 80 80 80
2TP04521825 13.5 37.5 89.9 91.9 95.4 97.4 90 100 100 100
2TP04522425 18.0 50.0 105.5 107.5 111.0 113.0 110 110 125 125
2TP04523625 25.5 70.8 131.5 133.5 137.0 139.0 150 150 150 150
None -- -- 43.0 45.0 48.5 50.5 60 60 60 60
2TP04520925 9.0 21.7 70.1 72.1 75.6 77.6 80 80 80 90
2TP04521825 18.0 43.3 97.2 99.2 102.7 104.7 100 100 110 110
2TP04522425 24.0 57.7 115.2 117.2 120.7 122.7 125 125 125 125
2TP04523625 34.0 81.8 145.3 147.3 150.8 152.8 150 150 175 175
None -- -- 21.6 22.6 23.8 24.8 30 30 30 30
2TP04520946 9 11.3 35.1 36.1 37.3 38.3 40 40 40 45
2TP04521846 18 22.6 48.6 49.6 50.8 51.8 50 50 60 60
2TP04522446 24 30.1 57.7 58.7 59.9 60.9 60 60 60 70
2TP04523646 34 42.7 72.7 73.7 74.9 75.9 80 80 80 80
None -- -- 17.1 18.3 18.9 20.1 20 25 25 25
2TP04520958 9 9.0 27.9 29.1 29.7 30.9 30 30 35 35
2TP04521858 18 18.1 38.8 40 40.6 41.8 40 40 45 45
2TP04522458 24 24.1 46 47.2 47.8 49 50 50 50 50
2TP04523658 34 34.1 58 59.2 59.8 61 60 60 60 70
*
4.0
4.1
Maximum HACR breaker of the same AMP size is applicable.
2.2 5.0
7.6 58.4 0.6 2.4 3.6 1.8
10.0
18.9 146.0 1.6 6.2 8.2 5.5 10.0
9.5
Electric Heater
Model No.
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
575
OD Fan
Motors
Supply
Blower
Motor FLA
Pwr
Exh
Motor
FLA
8.2 5.5
73.0 0.8 3.1
Voltage
Compressors
208
460
230
146.0 1.6 6.218.9
Pwr
Conv
Outlet
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA
035-17291-001-A-0903
30 Unitary Products Group
TABLE 43: ELECTRICAL DATA - BP/BA (7-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 44: ELECTRICAL DATA - BP/BA (7-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 6.8 18.9 61.6 63.6 67.1 69.1 70 70 70 70
2TP04521825 13.5 37.5 84.8 86.8 90.3 92.3 90 90 100 100
2TP04522425 18.0 50.0 100.5 102.5 106.0 108.0 110 110 110 110
2TP04523625 25.5 70.8 126.5 128.5 132.0 134.0 150 150 150 150
None -- -- 38.0 40.0 43.5 45.5 50 50 50 50
2TP04520925 9.0 21.7 65.1 67.1 70.6 72.6 70 70 80 80
2TP04521825 18.0 43.3 92.1 94.1 97.6 99.6 100 100 100 100
2TP04522425 24.0 57.7 110.2 112.2 115.7 117.7 125 125 125 125
2TP04523625 34.0 81.8 140.2 142.2 145.7 147.7 150 150 150 150
None -- -- 22 23 24.2 25.2 25 30 30 30
2TP04520946 9 11.3 35.6 36.6 37.8 38.8 40 40 40 40
2TP04521846 18 22.6 49.1 50.1 51.3 52.3 50 60 60 60
2TP04522446 24 30.1 58.1 59.1 60.3 61.3 60 60 70 70
2TP04523646 34 42.7 73.1 74.1 75.3 76.3 80 80 80 80
None -- -- 17.3 18.5 19.1 20.3 20 20 25 25
2TP04520958 9 9.0 28.2 29.4 30 31.2 30 30 30 35
2TP04521858 18 18.1 39 40.2 40.8 42 40 45 45 45
2TP04522458 24 24.1 46.2 47.4 48 49.2 50 50 50 50
2TP04523658 34 34.1 58.2 59.4 60 61.2 60 60 60 70
*
1.80.6 2.4 3.6
1.5
0.0
Maximum HACR breaker of the same AMP size is applicable.
0.0
7.7 64.0 0.8 3.1 4.1 2.2 0.0
130.0 5.5
8.2 5.5 0.0
12.8
12.8 130.0 1.5 6.2
6.2 8.2
460
575 6.1 52.0
208
230
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Max
Fuse*
Size
(Amps)Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 1.5 2 1.5 2 1.5 2 1.5 2 1.5 2
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 6.8 18.9 71.6 73.6 77.1 79.1 80 80 80 80
2TP04521825 13.5 37.5 94.8 96.8 100.3 102.3 100 100 110 110
2TP04522425 18.0 50.0 110.5 112.5 116.0 118.0 125 125 125 125
2TP04523625 25.5 70.8 136.5 138.5 142.0 144.0 150 150 150 150
None -- -- 48.0 50.0 53.5 55.5 60 60 60 60
2TP04520925 9.0 21.7 75.1 77.1 80.6 82.6 80 80 90 90
2TP04521825 18.0 43.3 102.1 104.1 107.6 109.6 110 110 110 110
2TP04522425 24.0 57.7 120.2 122.2 125.7 127.7 125 125 150 150
2TP04523625 34.0 81.8 150.2 152.2 155.7 157.7 175 175 175 175
None -- -- 27 28 29.2 30.2 30 35 35 35
2TP04520946 9 11.3 40.6 41.6 42.8 43.8 45 45 45 45
2TP04521846 18 22.6 54.1 55.1 56.3 57.3 60 60 60 60
2TP04522446 24 30.1 63.1 64.1 65.3 66.3 70 70 70 70
2TP04523646 34 42.7 78.1 79.1 80.3 81.3 80 80 90 90
None -- -- 21.3 22.5 23.1 24.3 25 25 25 30
2TP04520958 9 9.0 32.2 33.4 34 35.2 35 35 35 40
2TP04521858 18 18.1 43 44.2 44.8 46 45 45 45 50
2TP04522458 24 24.1 50.2 51.4 52 53.2 60 60 60 60
2TP04523658 34 34.1 62.2 63.4 64 65.2 70 70 70 70
*
1.8 4.0
Maximum HACR breaker of the same AMP size is applicable.
52.0 0.6 2.4 3.6
10.0
7.7 64.0 0.8 3.1 4.1 2.2 5.0
130.0 1.5 6.2 8.2
Pwr
Exh
Motor
5.5
FLA
12.8 130.0 1.5 6.2 8.2 5.5 10.0
Electric Heater
Model No.
Supply
Blower
Motor FLA
Max Fuse* Size
w/Power
Exhaust
(Amps)
Pwr
Conv
OutletHeater
Amps
Actual
KW
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Max
Fuse*
Size
(Amps)
FLA
460
575 6.1
208
230 12.8
Voltage
CompressorsOD Fan
Motors
035-17291-001-A-0903
Unitary Products Group 31
TABLE 45: ELECTRICAL DATA - BP/BA (8-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 46: ELECTRICAL DATA - BP/BA (8-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 48.3 51.0 53.8 56.5 60 60 60 70
2TP04520925 6.8 18.9 71.9 74.6 77.4 80.1 80 80 80 90
2TP04521825 13.5 37.5 95.1 97.8 100.6 103.3 100 100 110 110
2TP04522425 18.0 50.0 110.7 113.4 116.2 118.9 125 125 125 125
2TP04523625 25.5 70.8 136.8 139.5 142.3 145.0 150 150 150 150
None -- -- 48.3 51.0 53.8 56.5 60 60 60 70
2TP04520925 9.0 21.7 75.3 78.0 80.8 83.5 80 80 90 90
2TP04521825 18.0 43.3 102.4 105.1 107.9 110.6 110 110 110 125
2TP04522425 24.0 57.7 120.4 123.1 125.9 128.6 125 125 150 150
2TP04523625 34.0 81.8 150.5 153.2 156.0 158.7 175 175 175 175
None -- -- 24.6 25.8 26.8 28 30 30 30 35
2TP04520946 9 11.3 38.2 39.4 40.4 41.6 40 40 45 45
2TP04521846 18 22.6 51.7 52.9 53.9 55.1 60 60 60 60
2TP04522446 24 30.1 60.7 61.9 62.9 64.1 70 70 70 70
2TP04523646 34 42.7 75.7 76.9 77.9 79.1 80 80 80 80
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04520958 9 9.0 31.4 31.9 33.2 33.7 35 35 35 35
2TP04521858 18 18.1 42.3 42.8 44.1 44.6 45 45 45 45
2TP04522458 24 24.1 49.5 50 51.3 51.8 50 50 60 60
2TP04523658 34 34.1 61.5 62 63.3 63.8 70 70 70 70
*
1.8 0.0
Maximum HACR breaker of the same AMP size is applicable.
52.0 1.3 3.6 4.1
64.0 1.6 4.1
130.0 3.5 8.2
3.5 8.2 10.9130.0 5.5 0.0
5.5 0.0
5.3
10.9
2.2 0.0460
575
7.7
208
230
14.7
14.7
6.4
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Max
Fuse*
Size
(Amps)Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 58.3 61.0 63.8 66.5 70 70 70 80
2TP04520925 6.8 18.9 81.9 84.6 87.4 90.1 90 90 90 100
2TP04521825 13.5 37.5 105.1 107.8 110.6 113.3 110 110 125 125
2TP04522425 18.0 50.0 120.7 123.4 126.2 128.9 125 125 150 150
2TP04523625 25.5 70.8 146.8 149.5 152.3 155.0 150 150 175 175
None -- -- 58.3 61.0 63.8 66.5 70 70 70 80
2TP04520925 9.0 21.7 85.3 88.0 90.8 93.5 90 90 100 100
2TP04521825 18.0 43.3 112.4 115.1 117.9 120.6 125 125 125 125
2TP04522425 24.0 57.7 130.4 133.1 135.9 138.6 150 150 150 150
2TP04523625 34.0 81.8 160.5 163.2 166.0 168.7 175 175 175 175
None -- -- 29.6 30.8 31.8 33 35 35 35 40
2TP04520946 9 11.3 43.2 44.4 45.4 46.6 45 45 50 50
2TP04521846 18 22.6 56.7 57.9 58.9 60.1 60 60 60 70
2TP04522446 24 30.1 65.7 66.9 67.9 69.1 70 70 70 70
2TP04523646 34 42.7 80.7 81.9 82.9 84.1 90 90 90 90
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04520958 9 9.0 35.4 35.9 37.2 37.7 40 40 40 40
2TP04521858 18 18.1 46.3 46.8 48.1 48.6 50 50 50 50
2TP04522458 24 24.1 53.5 54 55.3 55.8 60 60 60 60
2TP04523658 34 34.1 65.5 66 67.3 67.8 70 70 70 70
*
8.2
1.8 4.0
Maximum HACR breaker of the same AMP size is applicable.
52.0 1.3 3.6 4.1
5.5
10.0
10.0
7.7 64.0 1.6 4.1 5.3 2.2 5.0
10.9
14.7 130.0 3.5 8.2 10.9 5.5
Max
Fuse*
Size
(Amps)
Supply
Blower
Motor FLA
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.Voltage
CompressorsOD Fan
Motors
460
3.5130.0
575 6.4
208
230 14.7
035-17291-001-A-0903
32 Unitary Products Group
TABLE 47: ELECTRICAL DATA - BP/BA (10 TON) WITHOUT POWERED CONVENIENCE OUTLET 60 HTZ.
TABLE 48: ELECTRICAL DATA - BP/BA (10 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 13.5 37.5 98.0 100.7 103.5 106.2 100 110 110 110
2TP04522425 18.0 50.0 113.7 116.4 119.2 121.9 125 125 125 125
2TP04523625 25.5 70.8 139.7 142.4 145.2 147.9 150 150 150 150
2HP04525425** 40.6 112.7 151.1 154.5 158.0 161.4 175 175 175 175
None -- -- 51.2 53.9 56.7 59.4 60 60 70 70
2TP04521825 18.0 43.3 105.3 108.0 110.8 113.5 110 110 125 125
2TP04522425 24.0 57.7 123.4 126.1 128.9 131.6 125 150 150 150
2TP04523625 34.0 81.8 153.4 156.1 158.9 161.6 175 175 175 175
2HP04525425** 54.0 129.9 153.4 156.1 158.9 161.6 175 175 175 175
None -- -- 29.6 30.8 31.8 33 35 40 40 40
2TP045211846 18 22.6 56.6 57.8 58.8 60 60 60 60 60
2TP045212446 24 30.1 65.7 66.9 67.9 69.1 70 70 70 70
2TP045213646 34 42.7 80.7 81.9 82.9 84.1 90 90 90 90
2HP04535446** 54 67.8 80.7 81.9 82.9 84.1 90 90 90 90
None -- -- 20.6 21.1 22.4 22.9 25 25 25 25
2TP04521858 18 18.1 42.3 42.8 44.1 44.6 45 45 45 45
2TP04522458 24 24.1 49.5 50 51.3 51.8 50 50 60 60
2TP04523658 34 34.1 61.5 62 63.3 63.8 70 70 70 70
2HP04535458** 54 54.2 61.5 62 63.3 63.8 70 70 70 70
*
** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are
locked-out.
Maximum HACR breaker of the same AMP size is applicable.
2.2 0.0
6.4 62.0 1.3 3.6 4.1 1.8 0.0
75.0 1.6 4.1
150.0 3.5 8.2
3.5 8.2 10.9150.0 5.5 0.0
5.5 0.0
5.3
10.9
460
575
9.9
208
230
16.0
16.0
Max Fuse Size*
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Max
Fuse*
Size
(Amps)Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 2 3 2 3 2 3 2 3 2 3
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 13.5 37.5 108.0 110.7 113.5 116.2 110 125 125 125
2TP04522425 18.0 50.0 123.7 126.4 129.2 131.9 125 150 150 150
2TP04523625 25.5 70.8 149.7 152.4 155.2 157.9 150 175 175 175
2HP04525425** 40.6 112.7 163.6 167.0 170.5 173.9 175 175 175 175
None -- -- 61.2 63.9 66.7 69.4 70 70 80 80
2TP04521825 18.0 43.3 115.3 118.0 120.8 123.5 125 125 125 125
2TP04522425 24.0 57.7 133.4 136.1 138.9 141.6 150 150 150 150
2TP04523625 34.0 81.8 163.4 166.1 168.9 171.6 175 175 175 175
2HP04525425** 54.0 129.9 163.4 166.1 168.9 171.6 175 175 175 175
None -- -- 34.6 35.8 36.8 38 40 45 45 45
2TP04521846 18 22.6 61.6 62.8 63.8 65 70 70 70 70
2TP04522446 24 30.1 70.7 71.9 72.9 74.1 80 80 80 80
2TP04523646 34 42.7 85.7 86.9 87.9 89.1 90 90 90 90
2HP04535446** 54 67.8 85.7 86.9 87.9 89.1 90 90 90 90
None -- -- 24.6 25.1 26.4 26.9 30 30 30 30
2TP04521858 18 18.1 46.3 46.8 48.1 48.6 50 50 50 50
2TP04522458 24 24.1 53.5 54 55.3 55.8 60 60 60 60
2TP04523658 34 34.1 65.5 66 67.3 67.8 70 70 70 70
2HP04535458** 54 54.2 65.5 66 67.3 67.8 70 70 70 70
*
** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are
locked-out.
1.8 4.0
Maximum HACR breaker of the same AMP size is applicable.
62.0 1.3 3.6 4.1
10.0
9.9 75.0 1.6 4.1 5.3 2.2 5.0
150.0 8.2 10.9
16.0 150.0 3.5 8.2 10.9 5.5
5.5
10.0
Max
Fuse*
Size
(Amps)
Supply
Blower
Motor FLA
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.Voltage
CompressorsOD Fan
Motors
460
3.5
575 6.4
208
230 16.0
035-17291-001-A-0903
Unitary Products Group 33
TABLE 49: ELECTRICAL DATA - BP/BA (12-1/2 TON) WITHOUT POWERED CONVENIENCE OUTLET60 HTZ.
TABLE 50: ELECTRICAL DATA - BP/BA (12-1/2 TON) WITH POWERED CONVENIENCE OUTLET 60 HTZ.
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 60.4 65.6 65.9 71.1 70 80 80 90
2TP04521825 13.5 37.5 107.3 112.5 112.8 118.0 110 125 125 125
2TP04522425 18.0 50.0 122.9 128.1 128.4 133.6 125 150 150 150
2TP04523625 25.5 70.8 148.9 154.1 154.4 159.6 150 175 175 175
2HP04535425** 40.6 112.7 154.5 161.0 161.4 167.9 175 175 175 175
None -- -- 60.4 65.6 65.9 71.1 70 80 80 90
2TP04521825 18.0 43.3 114.6 119.8 120.1 125.3 125 125 125 150
2TP04522425 24.0 57.7 132.6 137.8 138.1 143.3 150 150 150 150
2TP04523625 34.0 81.8 162.7 167.9 168.2 173.4 175 175 175 175
2HP04535425** 54.0 129.9 162.7 167.9 168.2 173.4 175 175 175 175
None -- -- 29.9 32.7 32.1 34.9 35 40 40 40
2TP04521846 18 22.6 56.9 59.7 59.1 61.9 60 60 60 70
2TP04522446 24 30.1 66 68.8 68.2 71 70 70 70 80
2TP04523646 34 42.7 81 83.8 83.2 86 90 90 90 90
2HP04535446** 54 67.8 81 83.8 83.2 86 90 90 90 90
None -- -- 23.8 25.7 25.6 27.5 30 30 30 35
2TP04521858 18 18.1 45.5 47.4 47.3 49.2 50 50 50 50
2TP04522458 24 24.1 52.7 54.6 54.5 56.4 60 60 60 60
2TP04523658 34 34.1 64.7 66.6 66.5 68.4 70 70 70 70
2HP04535458** 54 54.2 64.7 66.6 66.5 68.4 70 70 70 70
*
**
Maximum HACR breaker of the same AMP size is applicable.
2.2 0.0
7.6 58.4 1.3 4.1 6.0 1.8 0.0
73.0 1.6 5.3
146.0 3.5 10.9
3.5 10.9 16.1146.0 5.5 0.0
5.5 0.0
8.1
16.1
Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are
locked-out.
460
575
9.5
208
230
18.9
18.9
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.
Max
Fuse*
Size
(Amps)Voltage
CompressorsOD Fan
Motors
Supply
Blower
Motor FLA
RLA LRA FLA 3 5 3 5 3 5 3 5 3 5
ea. ea. ea. HP HP HP HP HP HP HP HP HP HP
None -- -- 70.4 75.6 75.9 81.1 80 90 90 100
2TP04521825 13.5 37.5 117.3 122.5 122.8 128.0 125 125 125 150
2TP04522425 18.0 50.0 132.9 138.1 138.4 143.6 150 150 150 150
2TP04523625 25.5 70.8 158.9 164.1 164.4 169.6 175 175 175 175
2HP045315425** 40.6 112.7 167.0 173.5 173.9 180.4 175 175 175 200
None -- -- 70.4 75.6 75.9 81.1 80 90 90 100
2TP04521825 18.0 43.3 124.6 129.8 130.1 135.3 125 150 150 150
2TP04522425 24.0 57.7 142.6 147.8 148.1 153.3 150 150 150 175
2TP04523625 34.0 81.8 172.7 177.9 178.2 183.4 175 200 200 200
2HP045315425** 54.0 129.9 172.7 177.9 178.2 183.4 175 200 200 200
None -- -- 34.9 37.7 37.1 39.9 40 45 45 45
2TP04521846 18 22.6 61.9 64.7 64.1 66.9 70 70 70 70
2TP04522446 24 30.1 71 73.8 73.2 76 80 80 80 80
2TP04523646 34 42.7 86 88.8 88.2 91 90 90 90 100
2HP045315446** 54 67.8 86 88.8 88.2 91 90 90 90 100
None -- -- 27.8 29.7 29.6 31.5 35 35 35 35
2TP04521858 18 18.1 49.5 51.4 51.3 53.2 50 60 60 60
2TP04522458 24 24.1 56.7 58.6 58.5 60.4 60 60 60 70
2TP04523658 34 34.1 68.7 70.6 70.5 72.4 70 80 80 80
2HP045315458** 54 54.2 68.7 70.6 70.5 72.4 70 80 80 80
*
** Only 34 kW of Electric heat can be simultaneously energized with the mechanical heating. The full 54 kW operates only if both compressors are
locked-out.
1.8 4.0
Maximum HACR breaker of the same AMP size is applicable.
58.4 1.3 4.1 6.0
10.0
9.5 73.0 1.6 5.3 8.1 2.2 5.0
146.0 10.9 16.1
18.9 146.0 3.5 10.9 16.1 5.5
5.5
10.0
Max
Fuse*
Size
(Amps)
Supply
Blower
Motor FLA
Max Fuse* Size
w/Power
Exhaust
(Amps)
FLA FLA
Actual
KW
Heater
Amps
Min. Circuit
Ampacity
(Amps)
MCA
w/Power
Exhaust
(Amps)
Pwr
Exh
Motor
Pwr
Conv
OutletElectric Heater
Model No.Voltage
CompressorsOD Fan
Motors
460
3.5
575 7.6
208
230 18.9
035-17291-001-A-0903
34 Unitary Products Group
TABLE 51: ELECTRICAL DATA - BP (7-1/2 TON) HP 50 HTZ.
Voltage
CompressorsODFan
Motors
Supply Air BLower
Motor FLA
Pwr Exh
Motor Electric Heater Model No.
Actual Kw
Heater Amps
Minimum Circuit Ampacity (Amps)
MCA with Power Exhaust (Amps)
Max Fuse Size*
(Amps)
Max Fuse Sizew/Pwr. Exh.*
(Amps)
RLA ea
LRA ea
FLA ea
1.5 HP(1.1 kW)
2 HP(1.5 kW)
FLA1.5 HP
(1.1 kW)2 HP
(1.5 kW)1.5 HP
(1.1 kW)2 HP
(1.5 kW)1.5 HP
(1.1 kW)2 HP
(1.5 kW)1.5 HP
(1.1 kW)2 HP
(1.5 kW)
380 8.3 62 1.1 4.3 5.2 2.2
None - - 25.2 26.1 27.4 28.3 30 30 35 35
2TP04520950 5.6 8.5 35.8 36.7 38.0 38.9 40 40 40 45
2TP04521850 11.3 17.2 46.6 47.5 48.8 49.7 50 50 50 50
2TP04522450 15.0 22.8 53.7 54.6 55.9 56.8 60 60 60 60
2TP04523650 21.3 32.4 65.6 66.5 67.8 68.7 70 70 70 70
415 8.3 62 1.1 4.3 5.2 2.2
None - - 25.2 26.1 27.4 28.3 30 30 35 35
2TP04520950 6.7 9.3 36.8 37.7 39.0 39.9 40 40 40 45
2TP04521850 13.5 18.8 48.7 49.6 50.9 51.8 50 50 60 60
2TP04522450 17.9 24.9 56.3 57.2 58.5 59.4 60 60 60 60
2TP04523650 25.4 35.3 69.3 70.2 71.5 72.4 70 80 80 80
* Maximum HACR breaker of the same amp size is acceptable.
TABLE 52: ELECTRICAL DATA - BP (10 TON) HP 50 HTZ.
VoltageCompressors
ODFan
Motors
Supply Air BLower
Motor FLA
Pwr Exh
Motor Electric Heater Model No.
Actual Kw
Heater Amps
Minimum Circuit Ampacity (Amps)
MCA with Power Exhaust (Amps)
Max Fuse Size*
(Amps)
Max Fuse Sizew/Pwr. Exh.*
(Amps)
RLA ea
LRA ea
FLA ea
2 HP(1.5 kW)
4HP(3 kW)
FLA2 HP
(1.5 kW)4 HP
(3 kW)2 HP
(1.5 kW)4 HP
(3 kW)2 HP
(1.5 kW)4 HP
(3 kW)2 HP
(1.5 kW)4 HP
(3 kW)
380 9.6 79 1.1 5.2 7.5 2.2
None - - 29.0 31.3 31.2 33.5 35 40 40 40
2TP04521850 11.3 17.2 50.5 52.8 52.7 55.0 60 60 60 60
2TP04522450 15.0 22.8 57.5 59.8 59.7 62.0 60 60 60 70
2TP04523650 21.3 32.4 69.5 71.8 71.7 74.0 70 80 80 80
2HP04525450Ü 33.8 51.4 70.7 73.6 73.4 76.3 80 80 80 80
415 9.6 79 1.1 5.2 7.5 2.2
None - - 29.0 31.3 31.2 33.5 35 40 40 40
2TP04521850 13.5 18.8 52.5 54.8 54.7 57.0 60 60 60 60
2TP04522450 17.9 24.9 60.1 62.4 62.3 64.6 70 70 70 70
2TP04523650 25.4 35.3 73.2 75.5 75.4 77.7 80 80 80 80
2HP04525450Ü 40.4 56.2 76.8 79.6 79.5 82.4 80 80 80 90
* Maximum HACR breaker of the same amp size is acceptable.Ü Only 25.4 kW of electric heat can be simultaneously energized with the mechanical heating. The full 40.4 kW operates only if both compressors are locked out.
TABLE 53: ELECTRIC HEAT MULTIPLIERS
VoltagekW Cap. Multiplier
Nominal Rating
240208 0.75
230 0.92
480 460 0.92
600 575 0.92
480380 0.63
415 0.75
TABLE 54: UNIT VOLTAGE LIMITATIONS
Power Rating Min. Max.
208/230-3-60 187 252
460-3-60 432 504
575-3-60 540 630
380/415-50 342 456
035-17291-001-A-0903
Unitary Products Group 35
NOTES
Subject to change without notice. Printed in U.S.A. 035-17291-001-A-0903Copyright © by Unitary Products Group 2003. All rights reserved. Supersedes: 035-17291-000 REV.B (0301)
Unitary 5005 NormanProducts York OKGroup Drive 73069
NOTES