ACCESSORY SELECTION TABLE AND CHASSIS IDENTIFICATION FORGOODMAN 2 - 15 TON PACKAGE ROOFTOP UNITS
1 1section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
PGC-1PGC-2PGC-3PGC-5PGP-5PGED-1PGED-2PGED-3PGED090/102-5PGED120/180-5PGEH-1PGEH-2PGEH-3PGEH090/102-5PGEH120/180-5PGMD1-3PGMD-5PGMDM1-3PGMDM-5SQRPG-1SQRPG-2SQRPG-3SQRPG090-5CDK1-2CDK-3CDK90
PGCT120-5PGFR-1PGFR-2PGFR-3PGHDK090/102-5PGHDK120/180-5
ROOF CURBROOF CURBROOF CURBROOF CURB4' PLENUM DROPS WITH CAPSDOWNFLOW ECONOMIZERDOWNFLOW ECONOMIZERDOWNFLOW ECONOMIZERDOWNFLOW ECONOMIZERDOWNFLOW ECONOMIZERHORIZONTAL ECONOMIZERHORIZONTAL ECONOMIZERHORIZONTAL ECONOMIZERHORIZONTAL ECONOMIZERHORIZONTAL ECONOMIZERMANUAL FRESH AIR DAMPERMANUAL FRESH AIR DAMPERMOTORIZED FRESH AIR DAMPERMOTORIZED FRESH AIR DAMPERSQUARE TO ROUND CONVERTERSQUARE TO ROUND CONVERTERSQUARE TO ROUND CONVERTERSQUARE TO ROUND CONVERTERCONCENTRIC CONVERTERCONCENTRIC CONVERTERCONCENTRIC CONVERTER
CONCENTRIC TRANSITIONDOWNFLOW FILTER RACKDOWNFLOW FILTER RACKDOWNFLOW FILTER RACKHORIZONTAL DUCT KITHORIZONTAL DUCT KIT
MODEL DESCRIPTIONCHASSIS
#1 #2 #3 #5A #5B•
••
••
••
••
••
••
••
• •
•
•
••
•
•
••
••
•• •
••
CDK120 CONCENTRIC CONVERTER ••
••
••
•
•
••
ACCESSORY SELECTION TABLE AND CHASSIS IDENTIFICATION FORGOODMAN 2 - 15 TON PACKAGE ROOFTOP UNITS (CON'T)
1 2section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
XXX - ALL HEATING INPUTS
CHASSIS #2PG024XXXPG030XXXPG036XXX
PGX024XXXPGX030XXXPGX036XXX
CHASSIS #3PG042XXXPG048XXXPG060XXX
PGX042XXXPGX048XXXPGX060XXX
PG/PGXSERIES
CHASSIS #2 CHASSIS #3
XXX - ALL HEATING INPUTS
PGJ036XXXPGJ042XXXPGJ048XXX
PGJ024XXXPGJ030XXX
PGJSERIES
CHASSIS #4PG090PG120PC090PC120
PG/PCSERIES
CHASSIS #1 CHASSIS #2 CHASSIS #3PGB042125PGB048075PGB048100PGB048125PGB048150PGB060100PGB060125PGB060150
PGB030100PGB036100PGB042075PGB042100
PGB024050PGB024075PGB030050PGB030075PGB036050PGB036075
PGBSERIES
XXX - ALL HEATING INPUTS
CHASSIS #5A CHASSIS #5BPGB120XXXPGB150XXXPGB180XXXPCB120PCB150PCB180
PGB090XXXPGB102XXX
PCB090PCB102
PGB/PCBSERIES
CHASSIS #1 CHASSIS #2 CHASSIS #3PHB042PGH048PHB060
PHB036PHB024PHB030
PHBSERIES
1 3section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
ACCESSORY REFERENCE LISTPCK / PCKJ / PHK / PHKJ – 2-5 TON PACKAGE ROOFTOP UNITS
PCK CHASSIS SIZES
PCK024-1PCK030-1PCK036-X
PCK042-XPCK048-X
PCK060-XSMALL MEDIUM LARGE
PHK CHASSIS SIZES
PHK024-1PHK030-1
PHK036-X PHK042-1PHK048-XPHK060-X
SMALL MEDIUM LARGE
PHJK CHASSIS SIZES
PHJK024-1PHJK030-1
PHJK036-1PHJK048-1PHJK060-1
SMALL MEDIUM LARGEPCKJ CHASSIS SIZES
PCKJ024-1PCKJ030-1
PCKJ036-1PCKJ042-1
PCKJ048-1PCKJ060-1
SMALL MEDIUM LARGE
NOTE: X is All Electronics Designations
NOTE: Down Flow Plenum includes Filter Rack
SMALL MEDIUM LARGEACCESSORIES
Roof CurbDown Flow PlenumManual Fresh Air DamperEconomizer - Down FlowSquare to Round Converter (Down Flow)Square to Round Converter (Horizontal)Elbow & Flashing
PCCP-1PCP-1PCMD-1PCE-1SQRPC-1SQRPCH-1PCEF-1
PCCP2-3PCP2-3PCMD2-3PCE2-3SQRPC2-3SQRPCH-2PCEF2-3
PCCP2-3PCP2-3PCMD2-3PCE2-3SQRPC2-3SQRPCH-3PCEF2-3
-
ACCESSORIES FOR PGB 2-15 TON
MODEL #
PGC-1
PGC-2
PGC-3
PGC-5
PGP-5
PGED-1
PGED-2
PGED-3
PGED090/102-5
PGED120/180-5
PGEH-1
PGEH-2
PGEH-3
PGEH090/102-5
PGEH120/180-5
PGMD 1-3
PGMD-5
PGMDM 1-3
PGMDM-5
CDK 1-2
CDK-3
CDK 90
CDK 120
CDK 150
CDK 180
PGHDK090/102-5
PGHDK120/180-5
DESCRIPTION
ROOF CURB
ROOF CURB
ROOF CURB
ROOF CURB
4' PLENUM DROPS
DOWNFLOW ECONOMIZER
DOWNFLOW ECONOMIZER
DOWNFLOW ECONOMIZER
DOWNFLOW ECONOMIZER
DOWNFLOW ECONOMIZER
HORIZONTAL ECONOMIZER
HORIZONTAL ECONOMIZER
HORIZONTAL ECONOMIZER
HORIZONTAL ECONOMIZER
HORIZONTAL ECONOMIZER
25% MANUAL FRESH AIR DAMPER
25% MANUAL FRESH AIR DAMPER
25% MOTORIZED FRESH AIR DAMPER
25% MOTORIZED FRESH AIR DAMPER
CONCENTRIC DUCT KIT
CONCENTRIC DUCT KIT
CONCENTRIC DUCT KIT
CONCENTRIC DUCT KIT
CONCENTRIC DUCT KIT
CONCENTRIC DUCT KIT
HORIZONTAL DUCT KIT
HORIZONTAL DUCT KIT
WEIGHT
52*
57*
67*
109*
135
49*
51*
62
78
101
69
69
83
90
115
8*
13*
10*
14*
35*
35*
55
160
190
225
37*
40*
1 4section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
1 5section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
MODEL # DESCRIPTION WEIGHT
MODEL # DESCRIPTION WEIGHT
ACCESSORIES FOR PCK/PHK 2-5 TON
* CAN BE SHIPPED BY UNITED PARCEL SERVICE
ACCESSORIES FOR PGB 2-15 TON (Cont.)
PCP-1 PLENUM 64PCCP-1 CURB & PLATFORM 78PCE-1 FULLY MODULATING ECONOMIZER (SLIDE IN) 37*PCMD-1 MANUAL DAMPER 10*PCMDM-1 MOTORIZED DAMPER 12*CDK1-2 CONCENTRIC DUCT KIT 35*SQRPC-1 SQUARE TO ROUND CONVERTER(DOWNFLOW) 17*SQRPCH-1 SQUARE TO ROUND CONVERTOR - HORIZ. DISCHARGE 6*PCEF-1 ELBOW & FLASHING 43PCP2-3 PLENUM 65PCCP 2-3 CURB & PLATFORM 99PCE 2-3 FULLY MODULATING ECONOMIZER (SLIDE IN) 39*PCMD 2-3 25% MANUAL FRESH AIR DAMPER 13*PCMDM2-3 25% MOTORIZED FRESH AIR DAMPER 15*CDK-3 CONCENTRIC DUCT KIT 35*SQRPC2-3 SQUARE TO ROUND CONVERTER (DOWNFLOW) 18*SQRPCH-2 SQUARE TO ROUND CONVERTER - HORIZ. DISCHARGE 7*SQRPCH-3 SQUARE TO ROUND CONVERTER - HORIZ. DISCHARGE 8*PCEF2-3 ELBOW & FLASHING 50
SQRPG-1 SQUARE TO ROUND CONVERTER 10*SQRPG-2 SQUARE TO ROUND CONVERTER 10*SQRPG-3 SQUARE TO ROUND CONVERTER 15*SQRPG090-5 SQUARE TO ROUND CONVERTER 25*PGFR-1 DOWNFLOW FILTER RACK 10*PGFR-2 DOWNFLOW FILTER RACK 10*PGFR-3 DOWNFLOW FILTER RACK 10*PGCT-5 CONCENTRIC TRANSITION 12
3 1section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
PGC-1, -2, & -3 ROOF CURBSFOR GOODMAN PGB, PHB, PGJ / 024 - 060 PACKAGE UNITS
MODELPGC-1PGC-2PGC-3
A3439
53.75�
B46.625�46.625�50.75�
C15.25�15.25�17.25�
D�15�17�
25.375�
E�18�21�
27.375�
ROOF CURBConstructed of minimum, 18 gauge galvanized steel.Features a 1" x 4" wood runner permanently attached to the top of the curb.Shipped unassembled with all hardware and instructions necessary forinstallation.
NOTE: DUCT SIZE SHOULD BE 3/8" LESS THAN O.D. OF DUCT OPENING.
1 1/2" TYP.
S
A
B
2 TYP.
D E
C
13 3/4"
1 1/2"
13 3/4"
2"
3/4"
4 1section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
SPECIFICATIONS:1. Fully modulating spring return 24 VAC motor.2. Provides up to 100% fresh air.3. Fully assembled and factory wired.4. Integral barometric relief. (25%)5. Painted to match unit.6. Adjustable enthalpy type.7. Adjustable mixed air temperature and minimum fresh air.8. Plugs into receptacle in unit, no field wiring.9. Replaces horizontal duct panel.10. All installation hardware and instructions included.
PGED-1, -2, -3DOWNFLOW ECONOMIZER
FOR GOODMAN PGB/PHB/PGJ-024 - 60 PACKAGE UNITS
MODELPGED-1PGED-2PGED-3
A20�20�20
B18.75�20.75�
27
C15.75�15.75�
17.625
D16.375�16.375�18.25
E18.125�20.125�26.375
4 2section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
SPECIFICATIONS:1. Fully modulating spring return 24 VAC motor.2. Provides up to 100% fresh air.3. Fully assembled and factory wired.4. Adjustable enthalpy type.5. Adjustable mixed air temperature and minimum fresh air.6. Plugs into receptacle in unit, no field wiring.7. Replaces horizontal duct panel.8. All installation hardware and instructions included.
PGEH-1, -2, -3HORIZONTAL ECONOMIZER
FOR GOODMAN PGB/PGJ & PHB-024 - 60 PACKAGE UNITS
MODELPGEH-1PGEH-2PGEH-3
A29�29�31
B20.5�22.5�
28.75
C16�16�16
D�12�12�13
E13.5�13.5�14.5
F18.5�20.5�
26.625
G9.25�9.25�9.25
4 3section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
SPECIFICATIONS:1. Fully modulating Economizer Package with 24 VAC damper motor and spring return.2. Provides up to 100% fresh air.3. Fully assembled and factory wired.4. Integral barometric relief. (100%)5. Painted to match unit.6. Adjustable enthalpy type.7. Adjustable mixed air temperature and minimum fresh air.8. Plugs into receptacle in unit.9. Replaces center access panel.10. All installation hardware and instructions included.
MODELPGED090/102-5PGED120/180-5
A32�48
B15.625�21.875
C13.375�23.250
D16�19
E8�
10.375
F40�40
PGED090/102-5 & PGED120/180-5DOWNFLOW ECONOMIZERS
FOR GOODMAN PGB(PCB)090 - 180 PACKAGE UNITS
4 4section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
SPECIFICATIONS:1. Fully modulating Economizer Package with 24 VAC damper motor and spring return.2. Provides up to 100% fresh air.3. Fully assembled and factory wired.4. Adjustable enthalpy type.5. Adjustable mixed air temperature and minimum fresh air.6. Plugs into receptacle in unit.7. Replaces center access panel after unit has been converted to horizontal discharge.8. All installation hardware and instructions included.
NOTE: Requires Horizontal Conversion Kit (PGHDK).
MODELPGEH090/102-5PGEH120/180-5
A40.125�40.125
B17.5�
25.75
C26�26
D38.125�38.125
E15.5�
23.375
F18�18
G15�18
PGEH090/102-5 & PGEH120/180-5HORIZONTAL ECONOMIZERS
FOR GOODMAN PGB(PCB)090 - 180 PACKAGE UNITS
510 SERIES concentric diffuser systems are designed to provide a single point air distribution system. The systems may be used with either a "T-Bar" ceiling or a plaster ceiling.
Standard features include:1. All aluminum diffuser with aluminum return air
eggcrate.2. Built-in Anti-Sweat gasket.3. Molded Fiberglass Transition (through five tons).4. Built-in hanging supports.5. Diffuser box constructed of fiberglass ductboard
(through 7.5 tons) or sheetmetal.
Standard benefits include:1. Even four (4) way airflow.2. Lightweight design.3. Factory assembled and sealed.4. Guaranteed not to "sweat".5. Guaranteed not to recirculate air flow (short cycle).6. Return air eggcrate is easily removed.7. Units are fully insulated (both supply and return).
LIGHT COMMERCIAL"T" BAR CEILING
COMMERCIAL"T" BAR CEILING
510 SERIES - FLUSH MOUNT CONCENTRIC DIFFUSER SYSTEM
5 1section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
MODEL NOCDK 1-2CDK 3
CDK90-210
A B C D E F G H I J DUCTSIZE
475/8
475/8
475/8
235/8
235/8
295/8
131/2
131/2
165/8
212127
454545
221/2
221/2
221/2
111/4
111/4
111/4
101/2
101/2
131/2
–––
–––
16RD18RD20RD
DIMENSIONAL DATA
CDK 120-510CDK 150-510CDK180-510CDK 140-510CDK 300-510
A B C D E F G H I J DUCTSIZE
475/8
475/8
475/8
595/8
595/8
355/8
415/8
475/8
595/8
595/8
231/4
291/4
291/4
351/4
351/4
3339455757
4545455757
41/2
41/2
41/2
41/2
41/2
1818182424
21/4
21/4
21/4
21/4
21/4
2832364854
21/2
31/4
41/2
41/2
11/2
18x2818x3218x3624x4824x54
MODEL NO
510 SERIES CONCENTRIC DIFFUSERENGINEERING DATA
CDK 24/36-510(CDK 1-2)
CDK 42/60-510(CDK 3)
600800
1000120014001000120014001600180020002200260028003000320034003600380040004200440046004800500052005400560058006000620064006600720074007600780080008200840086008800940096009800
10000102001040010600
.09
.11
.14
.17
.20
.14
.17
.20
.24
.30
.36
.40
.17
.20
.25
.31
.37
.17
.18
.21
.24
.27
.31
.32
.34
.36
.39
.36
.39
.42
.46
.50
.54
.39
.41
.43
.47
.50
.53
.56
.59
.63
.39
.41
.43
.45
.47
.50
.53
PART No CFM StatisticPressure
ThrowFeet
NeckVel.
JetVel.
NoiseLevel
10-1412-1815-2016-2217-2415-2016-2217-2418-2520-2821-2922-3019-2420-2821-2922-2922-3022-2922-3024-3326-3528-3725-3426-3527-3630-3932-4128-3729-3840-5042-5143-5245-5626-3528-3729-3840-5042-5143-5244-5446-5748-5930-4032-4135-4337-4640-5042-5143-53
234313�391�469�547�391�469�547�625�703�781�859�663�714�765�816�867�844�891938�985�
1032�922�962�
1002�1043�1083�1000�1036�1071�1107�1143�1179�996�
1024�1051�1079�1107�1134�1162�1189�1217�1014�1036�1057�1079�1101�1122�1144�
417556�694�833�972�694�833�972�1111�1250�1389�1528�1294�1393�1492�1592�1692�1646�1737�1829�1920�2011�1795�1873�1951�2029�2107�2082�2156�2230�2308�2379�2454�2093�2151�2209�2276�2326�2384�2442�2500�2558�2114�2159�2204�2249�2294�2339�2384�
1820202530�20�25�30�30�35�40�40�30�35�35�40�40�35�40�40�40�40�40�40�40�45�45�45�45�45�50�50�50�45�45�45�45�50�50�50�50�50�45�45�45�45�45�50�50�
CDK 90-510
CDK 120-510
CDK 150-510
CDK 180-510
CDK 240-510
CDK 300-510
Notes: 1. All data is based on the Air Diffusion Council Guidelines 2. Throw data is based on Terminal Velocities of 75 FPM using isothermal air 3. Actual noise levels are less than those shown.
TYPICAL SPECIFICATIONSFurnish and install McDaniel Metals, Inc. "510 SERIES"concentric diffuser systems. The system shall consist of an aluminum supply diffuser with an aluminum eggcrate return. It shall also have a permanent (not adhesive) anti-sweat gasket and hanging supports. All units that are five (5) tons and smaller shall have a molded fiberglass interior transition.
5 2section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
530 SERIES concentric diffuser systems are designed to provide a single point air distribution system with the added benefit of having directional air control. The systems may be used with either a "T-Bar" ceiling or a plaster ceiling.
Standard features include:1. All aluminum diffuser with aluminum return air eggcrate.2. Double deflection diffuser with the blades secured by
spring steel.3. Built-in Anti-Sweat gasket.4. Molded Fiberglass Transition (through five tons).5. Built-in hanging supports.6. Diffuser box constructed of fiberglass ductboard
(through 7.5 tons) or sheetmetal.
Standard benefits include:1. Even four (4) way airflow.2. All exposed surfaces (below ceiling) are brushed
aluminum.3. Factory assembled and sealed.4. Guaranteed not to "sweat".5. Guaranteed not to recirculate air flow (short cycle).6. Return air eggcrate is easily removed.7. Units are fully insulated (both supply and return).8. Lightweight design.
COMMERCIAL"T" BAR CEILING
section
LIGHT COMMERCIALPLASTER CEILING
MOLDED FIBERGLASSTRANSITION
(THRU 5 TONS ONLY)
530 SERIES - SIDE DISCHARGE CONCENTRIC DIFFUSER SYSTEM
5 3section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
TYPICAL SPECIFICATIONSFurnish and install McDaniel Metals, Inc. "530 SERIES" concentric diffuser systems. The system shall consist of an aluminum double supply diffuser with an aluminum eggcrate return. ALL EXPOSED SURFACES (BELOW CEILING) MUST BEBRUSHED ALUMINUM. It shall also have a permanent (not adhesive) anti-sweat gasket and hanging supports. All units that are five (5) tons and smaller shall have a molded fiberglass interior transition. section
Notes: 1. All data is based on the Air Diffusion Council Guidelines 2. Throw data is based on Terminal Velocities of 75 FPM using isothermal air 3. Actual noise levels are less than those shown. 4. Throw is based on diffuser blades being directed in a straight pattern.
530 SERIES CONCENTRIC DIFFUSERENGINEERING DATA
CDK 24/36-530(CDK 1-2)
CDK 42/60-530(CDK 3)
600800
10001200140010001200140016001800200022002600280030003200340036003800400042004400560058006000620064006600720074007600780080008200840086008800
.09
.11
.14
.17
.20
.14
.17
.20
.24
.30
.36
.40
.17
.20
.25
.31
.37
.17
.18
.21
.24
.27
.36
.39
.42
.46
.50
.54
.39
.41
.43
.47
.50
.53
.56
.59
.63
PART No CFM StatisticPressure
ThrowFeet
NeckVel.
JetVel.
NoiseLevel
8-159-16�10-17�11-18�12-19�10-17�11-18�12-19�12-20�13-21�14-23�16-25�24-29�25-30�27-33�28-35�30-37�25-33�27-35�29-37�32-40�34-42�39-49�42-51�44-54�45-55�46-55�47-56�33-38�35-40�36-41�38-43�39-44�41-46�43-49�44-50�47-55
210281�351�421�491�351�421�491�561�632�702�772�669�720�772�823�874�851�898�946�993�1040�920�954�1022�1056�1090�1124�827�850�873�896�918�941�964�987�1010
210281�351�421�491�351�421�491�561�632�702�772�669�720�772�823�874�851�898�946�993�1040�920�954�1022�1056�1090�1124�827�850�873�896�918�941�964�987�1010
2020�20�20�20�20�20�20�20�20�20�20�20�25�25�25�30�30�30�30�30�30�30�30�30�30�30�30�25�25�25�30�30�30�30�30�30
CDK 90-530
CDK 120-530
CDK 180-530
CDK 240-530
CDK24/36-530CDK42/60-530
CDK90-530
A B C D E F G H I J K L M DUCTSIZE
475/8
475/8
475/8
235/8
235/8
295/8
113/8
113/8
143/8
71/8
71/8
81/8
211/2
211/2
271/2
211/2
211/2
271/2
454545
221/2
221/2
221/2
451/2
451/2
451/2
111/2
111/2
111/2
103/4
103/4
133/4
16RD18RD20RD
–– –– ––
MODEL No
CDK120-530CDK180-530CDK240-530
A B C D E F G H I J K L M DUCTSIZE
475/8
475/8
595/8
355/8
475/8
595/8
205/8
245/8
305/8
451/2
451/2
571/2
331/2
451/2
571/2
91/8
101/8
111/8
331/2
451/2
571/2
451/2
451/2
571/2
23/4
43/4
43/4
41/2
41/2
41/2
283648
181824
21/2
21/2
21/2
18x2818x3624x48
MODEL No
DIMENSIONAL DATA
5 4section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
535 SERIES concentric diffuser systems are designed to provide a single point air distribution system with the added benefit of having directional air control and a return air filter. The systems may be used with either a "T-Bar" ceiling or a plaster ceiling or with no ceiling at all.
Standard features include:1. All aluminum diffuser with aluminum return air
eggcrate.2. Return air filter grill.3. Double deflection diffuser with the blades secured by
spring steel.4. Built-In Anti Sweat Gasket.5. Molded Fiberglass Transition (through five tons).6. Built-in hanging supports.7. Diffuser box constructed of fiberglass ductboard
(through 7.5 tons) or sheetmetal.
Standard benefits include:1. Even four (4) way airflow.2. All exposed surfaces (below ceiling) are brushed
aluminum.3. Factory assembled and sealed.4. Guaranteed not to "sweat"5. Guaranteed not to recirculate air flow (short cycle).6. Filter is removed from inside the conditioned space.7. Return air eggcrate is easily removed.8. Units are fully insulated (both supply and return).9. Lightweight design.
5 5section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
LIGHT COMMERCIALPLASTER CEILING
COMMERCIALNO CEILING
MOLDED CORE(THRU 5 TONS ONLY)
535 SERIES - SIDE DISCHARGE CONCENTRIC DIFFUSER WITH FILTER GRILL
TYPICAL SPECIFICATIONSFurnish and install McDaniel Metals, Inc. "535 SERIES" concentric diffuser systems. The system shall consist of an aluminum double deflection supply diffuser with an aluminum eggcrate filter grill return. ALL EXPOSED SURFACES (BELOW CEILING) MUST BE BRUSHED ALUMINUM. It shall also have a permanent (not adhesive) anti-sweat gasket and hanging supports. All units that are five (5) tons and smaller shall have molded fiberglass interior transition.
5 6section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
DIMENSIONAL DATA
530 SERIES CONCENTRIC DIFFUSERENGINEERING DATA
Notes: 1. All data is based on the Air Diffusion Council Guidelines. 2. Throw data is based on Terminal Velocities of 75 FPM using isothermal air 3. Actual noise levels are less than those shown. 4. Throw is based on diffuser blades being directed in a straight pattern.
CDK 24/36-535(CDK 1-2)
CDK 42/60-535(CDK 3)
600800
10001200140010001200140016001800200022002600280030003200340036003800400042004400560058006000620064006600720074007600780080008200840086008800
.17
.19�
.24�
.28�
.30�
.24�
.28�
.30�
.35�
.42�
.49�
.54�
.28�
.30�
.36�
.43�
.50�
.28�
.29�
.31�
.35�
.39�
.49�
.52�
.56�
.60�
.64�
.69�
.52�
.55�
.57�
.61�
.64�
.68�
.70�
.74�
.80
PART No CFM StatisticPressure
ThrowFeet
NeckVel.
JetVel.
NoiseLevel
8-159-16�10-17�11-18�12-19�10-17�11-18�12-19�12-20�13-21�14-23�16-25�24-29�25-30�27-33�28-35�30-37�25-33�27-35�29-37�32-40�34-42�39-49�42-51�44-54�45-55�46-55�47-56�33-38�35-40�36-41�38-43�39-44�41-46�43-49�44-50�47-55
210281�351�421�491�351�421�491�561�632�702�772�669�720�772�823�874�851�898�946�993�1040�920�954�1022�1056�1090�1124�827�850�873�896�918�941�964�987�1010
210281�351�421�491�351�421�491�561�632�702�772�669�720�772�823�874�851�898�946�993�1040�920�954�1022�1056�1090�1124�827�850�873�896�918�941�964�987�1010
2020�20�20�20�20�20�20�20�20�20�20�20�25�25�25�30�30�30�30�30�30�30�30�30�30�30�30�25�25�25�30�30�30�30�30�30
CDK 90-535
CDK 120-535
CDK 180-535
CDK 240-535
CDK 24/36-535CDK 42/60-535
CDK 90-535
A B C D E F G H I J K L M DUCTSIZE
475/8
475/8
475/8
235/8
235/8
295/8
113/8
113/8
143/8
71/8
71/8
81/8
211/2
211/2
271/2
211/2
211/2
271/2
451/2
451/2
451/2
221/2
221/2
221/2
451/2
451/2
451/2
111/2
111/2
111/2
103/4
103/4
133/4
16RD18RD20RD
––
––
––
MODEL No
CDK 120-535CDK 180-535CDK 240-535
A B C D E F G H I J K L M DUCTSIZE
475/8
475/8
595/8
355/8
475/8
595/8
205/8
245/8
305/8
451/2
451/2
571/2
331/2
451/2
571/2
91/8
101/8
111/8
331/2
451/2
571/2
451/2
451/2
571/2
23/4
43/4
43/4
41/2
41/2
41/2
283648
181824
21/2
21/2
21/2
18x2818x3624x48
MODEL No
6 1section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
PGMDM1-3 & PGMD1-3MOTORIZED / MANUAL FRESH AIR DAMPER
FOR PGB, PHB, PGJ/024 - 060 PACKAGE UNITS
Permanent Filter size - 11 3/4 x 5 3/4
MANUAL DAMPERSPECIFICATIONS:1) Provides from 0 to 25% outside air.2) Locking selection knob to maintain constant opening.
MOTORIZED DAMPERSPECIFICATIONS:1) 24 VAC damper motor with spring return2) Fully assembled and factory wired.
GENERALSPECIFICATIONS:1) Painted to match unit.2) All installation hardware and instructions included.
PGMDM-5 & PGMD-5MOTORIZED / MANUAL FRESH AIR DAMPER
FOR PGB(PCB)090 - 180 PACKAGE UNITS
6 2section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
MANUAL DAMPERSPECIFICATIONS:1) Provides from 0 to 25% outside air.2) Locking selection knob to maintain constant opening.
MOTORIZED DAMPERSPECIFICATIONS:1) 24 VAC damper motor with spring return2) Fully assembled and factory wired.3) When installing one motorized fresh air use the damper opening on the evaporator motor drive side of the equipment.
GENERALSPECIFICATIONS:1) One manual or motorized fresh air damper can be used for 0 to 25% outside air. Two accessories can be used for up to 50% outside air.2) Painted to match unit.3) All installation hardware and instructions included.4) Permanent Filter size - 14" x 9 1/2
PCMD-1, PCMD 2-3FOR GOODMAN PCK/PHK 024-060 PACKAGE UNITS
PCMD
NOTE: Replaces Economizer access door.
APPLICATION:For Use With PCP Plenum
6 3section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
6 4section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
PGFR-1, -2, -3DOWNFLOW FILTER RACK
FOR PGB024, PHB, PGJ - 060 PACKAGE UNITS
Note:PGFR cannot be used with downflow economizers.
MODELPGFR-1PGFR-2PGFR-3
A43/443/443/4
B187/8�207/8277/8�
FILTER SIZE16 X 18�16 X 2016 X 25�
C153/8�153/8173/8�
section
HORIZONTAL DUCT CONVERSION KITASSEMBLY AND INSTALLATION
ACCESSORY NUMBER PGHDK090/102-5FOR USE WITH: PGB 090 THRU 102
ACCESSORY NUMBER PGHDK120/180-5FOR USE WITH: PGB 120 THRU 180
GENERALThe horizontal air discharge accessory is used to convert a vertical discharge unit to horizontal supply and return air configuration. This accessory is intended to cover the air duct holes in the bottom of the unit, divide the discharge air return airstreams at the back of the unit and provide flanges for duct connections to the unit cabinet. Assembly and installation are the responsibility of the installing contractor.
INSPECTIONInspect accessory number to assure the unit model is correct. Verify that all parts and quantities of each item as shown below are included.
Quantity Description 2 Vertical Duct Hole Covers 1 Supply/Return Divider Panel 1 Top Duct Flange Angle 1 Bottom Duct Flange Angle 1 Center Duct Flange Channel 2 Discharge Duct Flange Side Angles 2 Return Duct Flange Side Angles 1 Fastnener Package
INSTALLATIONThis accessory is to be installed by an experienced installation company and fully trained personnel.CAUTION: Sheetmetal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the installer exercise caution.
1. Disconnect electrical power to the unit.2. Remove back panel and discard.3. Remove both filter access panels.4. Remove block-off panel that is located below the fan and evaporator coil section. Refer to Figure1. Remove two screws from each side and remove the panel through the back of the unit (discard panel). NOTE: Be careful not to damage firestats or the mixed air sensor that may be installed in the block-off panel supports.
Figure 1
section6 5page
M C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
section
HORIZONTAL AIR DISCHARGE CONVERSIONASSEMBLY AND INSTALLATION (cont.)
5. Install the cover panels for the discharge and return air holes in the bottom of the unit. The holes are the same size, and the covers are interchangeable. Insert the cover panel through the back opening in the cabinet turning as necessary to fit through the opening. Center the panel over the duct opening and drest the leading edge on the duct opening flange. Force the panel forward so the panel can drop down into position. Refer to Figure 2. The channels on the cover panel lock the panel in position. Check that the panel is securely engaged.
6. Install the supply/return divider panel through the back opening. Insert the panel at a downward angle so that the panel rests on top of the flanges "A" of the side triangular panels, and the front edge of the panel locks under the flange on the frame filter "B". Secure the panel to the cabinet with two screws.
7. Install the duct flanges to the cabinet and divider panel with screws as indicated. Refer to Figure 3. Apply duct sealant (field supplied) to the top return air angle and around screws to minimize moisture leakage. In addition, installer is responsible for providing a weather tight seal between the duct and the unit.
8. Replace filter access panels.
6 6section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
Figure 3
PGCT120-5CONCENTRIC TRANSITION
PGB(PCB)120 PACKAGE UNITS
APPLICATIONS
1) Concentric Transition can be used in conjunction with PGC-5 Roof Curb to easily connect curb to concentric converter.2) Duct work can be run from Concentric transition to Concentric Converter. Recommended Duct Size 18" X 28"
NOTE: Remove Center Duct Support On PGC-5 when using PGCT120-5
6 7section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
PGP-54" PLENUM DROPS W/CAPS
PGB(PCB) 090/180 PACKAGE UNITS
APPLICATIONS
SPECIFICATIONS1. Constructed of 22 Ga. sheetmetal2. Insulated with 1" duct liner3. Pinspotted4. S + drive end caps
1. 4' Plenum w/caps can be used in conjunction with PGC-5 Roof Curb to easily connect duct work
6 8section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
SQRPG-1, -2, -3SQUARE TO ROUND CONVERTER
FOR PGB, PHB, PGJ2024 - 060 PACKAGE UNITS
6 9section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
MODEL A B
SQRPG-3 16 18
SQRPG-1 14 16SQRPG-2 16 16
SQRPC-1 & SQRP-2-3SQUARE TO ROUND CONVERTER
FOR GOODMAN PCK/PHK024 - 060 PACKAGE UNITS
FEATURES:1. 20 ga. galvanized construction2. 1" insulation.
This square to round converter is used with PCP downflow plenums & PCCP Curb
6 10section
page2 8 1 . 9 8 7 . 8 4 0 0
M C D A N I E L M E T A L S
SQRPC-1SQRPC 2-3
A223/8281/8
B2929
C1618
MODEL
SQRPCH 1,2,3SQUARE TO ROUND CONVERTER FOR PCK/PHK UNITS (Horizontal Applications)
MODELSQRPCH-1SQRPCH-2SQRPCH-3
A121/8141/8141/8
SUPPLY RETURN
B121/8141/8141/8
C121414
D�121/8141/8141/8
E�201/8221/8241/8
F�14�1618�
CB
A D
FE
6 11section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
PCEF-1, PCEF 2-3DOWNFLOW ELBOW & FLASHING
FOR GOODMAN PCK / PHK 024 - 060 PACKAGE UNITS
FEATURES:1. 26 ga. galvanized construction.2. 1" insulation.3. Fully Assembled.4. Soldered flashing.5. Pin Spotted.
A281/2341/2
B281/4�321/4
MODELPCEF-1PCEF-2-3
C25�25�
D�201/4241/4�
E�20�20�
6 12section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
Efficient and affordable solutions.Efficient and affordable solutions.
• Accommodates Standard Filters• Accommodates Pleated, Electrostatic or Throw Away Filters• Embossed Heavy Gauge Steel Construction• Completely Insulated• Individually Boxed For Convenient Shipping and Warehousing• Sizes to Accommodate All Furnaces Through 5 Tons.• Access Knob Can Be Positioned Up or Down
The Accommodator enables the homeowner access to the filter without entering the furnace.
• Available in 2 Sizes (1 - 3 Ton) (3.5 - 5 Ton)• Adjustable Filter Rack 1”, 2”, 4”• Uses Standard Filter Sizes• Easy Access From Both Sides• Lined with 1” Insulation• Embossed Heavy Gauge Steel Construction• Makes Installation Faster and More Efficient• Filter Positioned on an Angle for Maximum Surface Area• No Hardware to Remove for Filter Access
An Affordable Solution For Residential and Light Commercial Applications
The Labor Saver enables the homeowner access to the filter without entering the furnace.
• Available in 4 Sizes (1 - 5 Ton)• Easy Filter Access Through Hinged Door• Powder Painted White• All Steel Construction• Designed For Ceiling or Wall Applications For Central Return• Mounts Flush• Accommodates sizes Through 5 Tons• Adjustable Filter Rack 1”,2”,4”• Uses Standard Filter Sizes
The Accommodator II is easily surface mounted in the location normally occupied by the return air grill of the central heating/cooling system. It can be installed in the wall/ceiling of any residential/commercial structure. Drop down filter door makes easy access to filters and will handle 2000 CFM. Filter may be purchased at your local wholesaler or distributor. Made in USA.
Available in 8 sizes to handle 1,2, 0r 4 inch filters. Also available in 8 sizes to handle 1 or 2 inch filters, for all gas and electric furnaces through 5 tons.
Model LS
Model ACII
All Filter HousingsMade in the USA.
A tight seal is created by gaskets on access door.
A tight seal is created by gaskets on access doors.
7 1section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
Model ACG & ACE
• Attractive Design For Today’s Homes(New Or Remodeled)
The Accommodator II enables the homeowner access to the filter without entering the furnace.
Efficient and affordable solutions.Efficient and affordable solutions.
Available in 4 sizes• Available In 4 Models: HR and *HRB's.• Standard Filter 1",2" or 4"• For Horizontal Applications• Individually Boxed For Convenient Shipping And Warehousing• Completely Insulated• HR Model Is Open On One Side And Blocked Off On The Other Side, Cut Blocked Side To Your Furnace Specifications• * HRB Model Is Blocked Off On Both Sides, Cut To Fit Your Furnace Specifications And The Existing Plenum
HR Model
CF MODEL
ACIII MODEL
• Available In 4 Sizes (1 - 5 ton)• Accommodates Standard Filters 10x20x1• Counterflow Housing• Embossed Heavy Gauge Steel Construction• Completely Insulated• Easy Access To Filters• Filters Positioned On Angles For Maximum Surface Area
• Available In 1 Size (20x25)• Adjustable Filter Track Accommodates 1" - 7" Filter Widths• Embossed Heavy Gauge Steel Construction• Completely Insulated• Easy Access To Filters• Designed For Side Return Or Horizontal Return Applications• Accommodates Pleated, Electrostatic Or Throwaway Filters• Also Any Manufactured Replacement Cardboard Framed Media Filters i.e. Honeywell, Trion and Whiterogers.• Outside Dimension W 251/2 H 233/4 D 91/2
• Flange Opening W 221/2 H 20• Non-flange Opening w 213/8 H 193/8
The concept behind all McDaniel Metals filter Housings is the design of a product that will accommodate a variety of filter types and efficiencies at a very competitive price. In today's age of indoor quality, you cannot have too many filter choices.
A tight seal is created by gaskets on access door.
7 2section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
The Accommodator III enables the homeowner a wide variety of filter choices and efficiencies.
The Horizontal filter housing gives the home owner the option of a 1",2" or 4" filter. The Horizontal Filter Housing gives you many choices of filter types and sizes.
The Counterflow Filter Housing enables the homeowner access to the filters without interference from the vent pipe when changing a filter.
A
DCE
B
GF
GAS FURNACE ACCESSORIES
• No Furnace Panels or Door To Remove• Uses Standard Size Filters• Heavy-Gauge Steel Construction• Filter Base Is Insulated On All 4 Sides• Makes A Professional Installation
MODELNUMBER
GMP050-3 ACG1425-3"/6"
ACG1425-3"/6"
ACG1625-3"/6"ACG2025-3"/6"ACG2025-3"/6"
ACG2025-3"/6"
ACG2025-3"/6"
ACG2025-3"/6"
ACG1425-3"/6"ACG1625-3"/6"ACG2025-3"/6"
ACG2424-3"/6"
ACG1625-3"/6"
GMP075-3
GMP075-4
GMPV100-3/5GMPV125-3/5
GMP100-5GMP125-4
GMP125-5
GMN060-3GMN080-4GMN100-4
GMN120-5GMPV075-1 5/3
FILTER BASEREQUIRED
FILTER BASEREQUIRED
MODELNUMBER
Up-Flo Gas Furnaces
Short base handles 1" & 2" filters. Height 33/4
Tall base handles 1", 2" & 4" filters. Height 53/4
The Accommodator: Making yourcustomer's filter changes convenient.
MODELNUMBER
FILTERSIZE
OVERALL
Physical Data & Specifications
OPENING TOPB CA ED GF
*ACG1425-3/6 153/8
173/8
213/8
253/8
283/8
283/8
283/8
283/8
127/8
147/8
187/8
227/8
26262626
11/2 1111
11/2
11/2
11/2
1425162520252424
3/63/63/6
3/6
*ACG1625-3/6*ACG2025-3/6
*ACG2424-3/6
*3 represents 33/4" overall height of filter base . (handles 1 or 2 inch filters)
*6 represents 53/4" overall height of filter base. (handles 1, 2, or 4 inch filters)
Made in USA
7 3page
M C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
section
A
DCE
B
GF
• No Furnace Panels or Door To Remove• Uses Standard Size Filters• Heavy-Gauge Steel Construction• Filter Base Is Insulated On All 4 Sides• Makes A Professional Installation
The Accommodator: Making yourcustomer's filter changes convenient.
MODELNUMBER
FILTERSIZE
OVERALL
Physical Data & Specifications
OPENING TOPB CA ED GF
MODELNUMBER
FCP24 ACE1420-3"/6"
ACE1420-3"/6"
ACE1420-3"/6"
ACE2025-3"/6"N
ACE2025-3"/6"N
ACE1620-3"/6"ACE1620-3"/6"
ACE1620-3"/6"
ACE2020-3"/6"
FCX24
FCP30FCP36FCX36FCP42
FCP48
ACE2025-3"/6"NFCX48
FCP60FCX60
FILTER BASEREQUIRED
FILTER BASEREQUIRED
MODELNUMBER
Heat Pump Air Handlers and Fan Coil Units
*ACE1420-3/6 153/8
173/8
213/8
263/8
22222222
137/8
147/8
187/8
237/8
19191919
11/2 1111
11/2
11/2
11/2
1420162020202025
3/63/63/6
3/6
*ACE1620-3/6*ACE2020-3/6
*ACE2025-3/6
263/8 22 225/8 19 111/2 20253/6*ACE2025N-3/6
*3 represents 33/4" overall height of filter base . (handles 1 or 2 inch filters)
*6 represents 53/4" overall height of filter base. (handles 1, 2, or 4 inch filters)
Made in USA
7 4section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
7 5page
M C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
section
7 6section
pageM C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
Filter Door U Channel
Cut HoleTo Fit Unit
S Clip
End Cap
S & Drive End Cap
RAFP 2025RETURN AIR FILTER PLENUM
1. Cut hole in S & drive endcap to fit unit return air and attach to unit2. Attach plenum to S & drive end cap using S's & drives provided3. Install desired filter and door
Note: For 4" filter, remove U Channel Spacers.
Available in 2' or 3' lengthsFits most furnaces & air handlers through 5 ton.
7 7page
M C D A N I E L M E T A L S
2 8 1 . 9 8 7 . 8 4 0 0
section
CoilPlenum/Filter Rack
Upflo Accommodator
Basement Application Labor Saver
Accommodator Highboy
Plenum
1",2" and 4" Filter Capacity
1",2" and 4" Filter Capacity
1",2" and 4" Filter Capacity
1",2" and 4" Filter Capacity
Plenum /Filter Rack Horizontal Furnace / Mounted On Furnace Feet
Coil
Transition PlenumDrain Pan
AccommodatorFilter Base
Labor Saver
PLENUMS • TRANSITIONS • FILTER HOUSING
Plenums
Drain Pans
Transitions
Horizontal Furnace Stands
Accommodator Filter Housing Labor Saver Filter HousingR/A Filter Plenums(1",2" and 4" Filter Capacity)
1"2"4"
1",2",4"
• All Transitions, Plenums, and Return Air Cans are Individually Boxed and Labeled to Your Specification• Boxing Makes Warehousing and Shipping Much More Efficient And Convenient with Less Damage and Injury• Heavy Ga. Steel Drain Pans with Welded Corners and Welded Steel Nipples.• Transitions, Plenums, Return Air Cans Vary in Size and Styles Let us Quote You on the Requirements in Your Market.