accurate easy to use reliable - keison products∅ 80 ∅100 ∅180 180 x180 1) 2) dual ∅ 80...
TRANSCRIPT
-
Simply AccurateBuilt For Universal Use
Classic BalancesAccurate
Easy to use
Reliable
Clas
sic
Bala
nces
-
÷×
Weighing process adapter with four differentsettings assures optimal weighing performance.
Weighing results in different units: kg, g, mg, lb, oz, ozt, GN, dwt, mo, m, tl.
"Free Factor" for multiplication and division(except Classic balances).
Vibration adapter. Damps influences due tovibrations and minor shocks, even in difficultenvironments (except Classic balances).
Protective cover encloses the entire housingpreventing damage to the balance.
Brilliant backlit display (except 0.01 mg models).
Standard RS232C interface for connection to PC and printer.
Hook for weighing below the balance.
Certified versions of all models available.
High-grade chemical-resistant die-castaluminium housing reliably protects theweighing cell and electronics.
Easy-to-use application programs built-in as standard:• Piece counting with simple reference
selection• % weighing• Dynamic weighing with automatic
or manual start
Fully automatic adjustment with an internalweight.
Clas
sic
Bala
nces Free your mind
With Simple Weighing Technology
All balances offer the following:
Changes in temperature have a direct influence on the accuracy of your weighingresults. Although we cannot alter physics, with FACT we can eliminate these influencesautomatically – and free your mind for more important tasks. With Classic Plus balancesfrom METTLER TOLEDO weighing becomes as worry-free as can be, leaving you sure ofone thing: accurate results, in any climate.
-
-2°C
L
÷×"Free Factor" for multiplication and division(except Classic balances).
Temperature changes influence the accuracy of theweighing result. FACT adjusts the balanceautomatically any time the sensor detects a valueabove or below the permissible tolerance limits.
Time
Lower limit
Weight
Upper limit
Weight displayed
AccurateOur Classic Plus balances feature FACT, the Fully AutomaticCalibration Technology from METTLER TOLEDO. FACT automatically initiates the adjustment of your balance withinternal weights whenever temperature changes riskaffecting the accuracy of your weighing results. You benefittwice: firstly, you are sure that your measurements areaccurate under all conditions and, secondly, FACT savesyou time and worry because you can forget those time-consuming checks using external weights or a manually-triggeredinternal adjustment.
Easy to useThe clear menu with easy-to-use application programs, abrilliant backlit display and simple cleaning make thesebalances ideal to work with every day.
ReliableAll Classic Level balances are designed for a long servicelife. Rugged metal housing, durable sensor keys andoverload protection guarantee strong performance inlaboratories as well as in harsh industrial environments.
Flexible with Free FactorThe "Free Factor" function might be used to multiply, inorder calculate the price of say material weight directly.Alternatively, to divide, in order calculate the weight perdefined unit.
-
∅ 80
∅100
∅180
180 x180
1)
2)
Dual
∅ 80
∅100
∅180
349 x 232
Classic PlusReadability Max. capacity Model Adjustment MonoBloc Repeatability Linearity Weighing pan (mm)0.01 mg 31 g/120 g 1) AB135-S/FACT FACT 0.03 mg/0.1 mg 0.2 mg
61 g/220 g 1) AB265-S/FACT FACT 0.03 mg/0.1 mg 0.2 mg51 g AB54-S/FACT FACT ■ 0.1 mg 0.2 mg
0.1 mg 110 g AB104-S/FACT FACT ■ 0.1 mg 0.2 mg220 g AB204-S/FACT FACT 0.1 mg 0.2 mg320 g AB304-S/FACT FACT ■ 0.1 mg 0.4 mg151 g PB153-S/FACT FACT ■ 0.001 g 0.002 g310 g PB303-S/FACT FACT ■ 0.001 g 0.002 g
0.001 g 60 g /310 g 2) PB303-SDR/FACT FACT ■ 0.001 g/0.008 g 0.01 g410 g PB403-S/FACT FACT ■ 0.001 g 0.002 g510 g PB503-S/FACT FACT ■ 0.001 g 0.002 g610 g PB602-S/FACT FACT ■ 0.01 g 0.02 g
1510 g PB1502-S/FACT FACT ■ 0.01 g 0.02 g0.01 g 3100 g PB3002-S/FACT FACT ■ 0.01 g 0.02 g
600 g /3100 g 2) PB3002-SDR/FACT FACT ■ 0.01 g/0.08 g 0.1 g4100 g PB4002-S/FACT FACT ■ 0.01 g 0.02 g1510 g PB1501-S/FACT FACT ■ 0.08 g 0.1 g
0.1 g 3100 g PB3001-S/FACT FACT ■ 0.08 g 0.1 g5100 g PB5001-S/FACT FACT ■ 0.08 g 0.1 g8100 g PB8001-S/FACT FACT ■ 0.08 g 0.1 g
1 g 8100 g PB8000-S/FACT FACT ■ 0.8 g 1 g
ClassicReadability Max. capacity Model Adjustment MonoBloc Repeatability Linearity Weighing pan (mm)0.01 mg 61 g/220 g 1) AB265-S Cal Int 0.03 mg/0.1 mg 0.2 mg
51 g AB54-S Cal Int ■ 0.1 mg 0.2 mg0.1 mg 110 g AB104-S Cal Int ■ 0.1 mg 0.2 mg
220 g AB204-S Cal Int 0.1 mg 0.2 mg320 g AB304-S Cal Int ■ 0.1 mg 0.4 mg151 g PB153-L Cal Ext ■ 0.001 g 0.002 g
0.001 g 310 g PB303-L Cal Ext ■ 0.001 g 0.002 g60 g /310 g 2) PB303-LDR Cal Ext ■ 0.001 g/0.008 g 0.01 g
610 g PB602-L Cal Ext ■ 0.01 g 0.02 g0.01 g 1510 g PB1502-L Cal Ext ■ 0.01 g 0.02 g
3100 g PB3002-L Cal Ext ■ 0.01 g 0.02 g600 g /3100 g 2) PB3002-LDR Cal Ext ■ 0.01 g/0.08 g 0.1 g
1510 g PB1501-L Cal Ext ■ 0.08 g 0.1 g0.1 g 3100 g PB3001-L Cal Ext ■ 0.08 g 0.1 g
5100 g PB5001-L Cal Ext ■ 0.08 g 0.1 g8100 g PB8001-L Cal Ext ■ 0.08 g 0.1 g
1 g 8100 g PB8000-L Cal Ext ■ 0.8 g 1 g8100 g SB8001 Cal Ext ■ 0.1 g 0.2 g
12100 g SB12001 Cal Ext ■ 0.1 g 0.3 g0.1 g 16100 g SB16001 Cal Ext ■ 0.1 g 0.3 g
3200 g /16100 g 2) SB16001DR Cal Ext ■ 0.1 g/0.5 g 0.3 g /0.5 g4800 g /24100 g 2) SB24001DR Cal Ext ■ 0.1 g/0.5 g 0.3 g /0.5 g6400 g /32100 g 2) SB32001DR Cal Ext ■ 0.1 g/0.5 g 0.3 g /0.5 g
8100 g SB8000 Cal Ext ■ 0.5 g 0.5 g1 g 16100 g SB16000 Cal Ext ■ 0.5 g 0.5 g
32100 g SB32000 Cal Ext ■ 0.5 g 0.5 g
Our line-up, your choice
Fine range from 0–28% of the weighing range,depending on the model
Ten times higher readability over the entire weighingrange at a keystroke. Depending on the model, thisfine range covers up to 20% of the coarse range
MonoBloc weighing technology for fast and accurateresults
Fully automatic adjustment with an internal weight
Adjustment at a keystroke with an internal weight
Adjustment with externalweights
-
Tough stuff Built-in shock and overloadprotection for durabilitywithout compromise.
Built-in adjustment weightAll models (except PB-L) areequipped with an internaladjustment weight.
What always counts:Simple design and extremely rugged construction for an exceptionally long life.
High-performance weighingMonoBloc weighing technology for fastand accurate results.
Built-in adjustment weightAll models (except PB-L) areequipped with an internaladjustment weight.
Protection guaranteedUpper and lower housing is madeof chemical-resistant die-cast aluminium. Additional protectionis provided by the in-use cover.
Rugged sensor keysPractically non-wearing, especiallyeasy to clean.
Tough stuff Built-in shock and overloadprotection for durabilitywithout compromise.
Service tailored to your needsBenefit from the many years ofMETTLER TOLEDO experienceand global knowledge. We offerreliability and long life for yourbalance. A service whichquickly pays for itself. Find more information atwww.mt.com/service
Protected plug with interfacesThe housing reliablyprotects the AC adapterand RS232C portagainst spilt samples.
What always counts:Simple design and extremely rugged construction for an exceptionally long life.
supportText Box
-
Accessories for Classic balances from METTLER TOLEDOmake specific applications even easier.
LC-P45 PrinterOrder No. 00229119Applications:• Statistical functions• Totaling results• Multiplication and division
RS-P26 PrinterOrder No. 12120788Applications:• Ergonomically designed operation
keys like Zero, Date/Time, Feed,Print
Density kitOrder No. 00033360For determining thedensity of solids.
USB-232 CableOrder No. 11103691The USB-232 converter is anexpansion module thatconnects to a PC USB port.
Anti-theft deviceOrder No. 00590101Steel cord with locksecures the balance.
LabX direct balanceOrder No. 11120340Simple data input byconnecting the balanceto a PC.
RS/LC-BLD aux. displayOrder No. 00224200On bench stand witha backlit LC display.
AccuPac B-SOrder No. 21254691For portable weighing. Rechargeableexternal power supply up to 18 hoursof operation.
RS232 auxiliary display Order No. 12120057The backlit auxiliary display can beplaced elsewhere.
WeightsWeight for tests and adjustments.Guaranteed traceability.
www.mt.com/weights
Excellence Plus XP Excellence XS
If your balance is used in aregulated environment or if theemphasis is on productivity,we recommend balances fromour Excellence Level.
Mettler-Toledo AGLaboratory & Weighing TechnologiesCH-8606 Greifensee, SwitzerlandTel. +41-44-944 22 11Fax +41-44-944 30 60
Subject to technical changes© 01/2007 Mettler-Toledo AG Printed in Switzerland 11795499
For more information
Quality certification. Development, production and auditing inaccordance with ISO 9001.Environmental management system inaccordance with ISO 14001.
Worldwide Service. Our service network guaranteesmaximum availability and service life ofyour product.
“Communauté Européenne”.This CE label is your guarantee that ourproducts conform to the latest Europeanguidelines.
www.mt.com/classic
supportText Box
-
Thank you for reading this data sheet.
For pricing or for further information, please contact us at our UK Office, using the details below.
UK OfficeKeison Products,
P.O. Box 2124, Chelmsford, Essex, CM1 3UP, England.Tel: +44 (0)330 088 0560Fax: +44 (0)1245 808399
Email: [email protected]
Please note - Product designs and specifications are subject to change without notice. The user is responsible for determining the suitability of this product.
mailto:[email protected]://www.keison.co.uk
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure false /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles false /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /DocumentCMYK /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /UseDocumentProfile /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice