accuscan 1000 series - betalasermike.com · measure manufactured parts or cut samples fast and with...

4
Measure manufactured parts or cut samples fast and with the highest accuracy Perform reliable, non-contact measurements from run to run Benefit from easy-to-use features for simple setup and operation ACCUSCAN 1000 SERIES Accurate, Versatile Diameter Measurement Making Light Work

Upload: duongbao

Post on 31-Oct-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Measure manufactured parts or cut samples fast and with the highest accuracy Perform reliable, non-contact measurements from run to run Benefit from easy-to-use features for simple setup and operation

ACCUSCAN 1000 SERIES

Accurate, Versatile Diameter Measurement

Making Light Work

The AccuScan 1000™ family of modular gauges is the latest generation of laser micrometers from the inventors of the laser micrometer. The AccuScan 1000 series has integrated measurement and communications capabilities while maintaining the accuracy and reliability you’ve come to expect from Beta LaserMike products. Due to in-head Digital Signal Processing, higher scan rates, Fieldbus connectivity and enhance measurement algorithms, the AccuScan 1000 series can go where no laser micrometer has gone before. With a range of models covering dimensions up to 330 mm, the AccuScan 1000 brings precision measurement to your process.

Accuracy In Any PositionRegardless of your application’s size or environmental constraints, the AccuScan 1000 is up to the challenge. The separable transmitter and receiver allow placement without interference and protection from severe temperature or other environmental challenges. The AccuScan 1000 performs in any orientation and has multiple mounting surfaces to simplify fixturing. Add to that the AccuScan 1000’s immunity to product movement and you’ve got a combination that’s hard to beat. No matter where you position an AccuScan 1000 in your process, you get precise, consistent measurement data due to precision-ground optical lenses, high-stability rotating mirrors, integrated digital signal processing, and high-performance communications ports. A rugged, cast and machined aluminum case sealed to NEMA 4 and IP 65 standards keeps out moisture and dirt—even in the harshest environments. There’s also an optional air-wipe system that minimizes lens contamination, and proprietary software that compensates for any debris that finds it way onto the lens. In fact, AccuScan 1000 measurements are so stable that after a year of continuous operation most users will have no need to recalibrate the gauge. The result is a non-contact measurement system that consistently supplies accurate dimensional data—and keeps your line producing high-quality, cost-efficient product.

Flexible ConnectivityThe AccuScan 1000 is available in DeviceNet, Profibus, or RS-232 (standard) versions. This unrivalled flexibility ensures that there is always an optimal solution for getting data from an AccuScan 1000 to the system of your choice. Connecting to a PLC, PC, or Beta LaserMike controller has never been easier. The AccuScan 1000 also utilizes industry-standard “D” and Euro-fast connectors for easy cabling and in-field wiring. And because the transmission is digital, you’re assured of error-free data, untainted by electrical interference or signal degradation.

AccuScan 1000-R Communication Port: RS232. Used with: DataPro 1000, DataPro 3100, or PC/PLC

AccuScan 1000-P Communication Port: Profibus DP slave. Used with: Profibus DP network

AccuScan 1000-D Communication Port: DeviceNet slave. Used with: DeviceNet network

Making Light Work

Intelligent Dimensional Measurement

Performance Specifications*

*Based on 500 scans/second (standard).

1Fixed gauge pin diameter measurement repeatability for 3 minutes with gauge set to 1024 scan averaging.2Guaranteed within measururement range and at standard working distance (scanner mounted to standard rail).

3Guaranteed within ±2°C of calibration temperature and within 12 months of calibration date.4Linearity specifications apply for 80% of measurement range unless specified.

AS1050 AS1100 AS1140 AS1190 AS1330Measurement Range 0.36 - 50.80 mm 1.3 - 101 mm 0.76 - 139.7 mm 1.1 - 190.5 mm 6.35 - 330.2 mm (0.014-2.000 in.) (0.050-4.000 in.) (0.030-5.500 in.) (0.050-7.500 in.) (0.250-13.000 in.)Display Resolution 1 µm 1 µm 1 µm 1 µm 1 µm (0.00004 in.) (0.00004 in.) (0.00004 in.) (0.00004 in.) (0.00004 in.)Dimensional Linearity2,3,4 ±2.5 µm ± 6.4 µm ±20 µm ±25 µm ±76 µm (±0.00010 in.) (±0.00025 in.) (±0.00080 in.) (±0.0010 in.) (±0.0030 in.)Repeatability1,2 ±0.64 µm ±1.0 µm ±2.5 µm ±6.4 µm ±6.4 µm (or ±0.005% of the reading (±0.000025 in.) (0.000040 in.) (±0.00010 in.) (±0.00025 in.) (±0.00025 in.) whichever is greater)

Making Light Work

ElectricalGeneral

AS1050 AS1100 AS1140 AS1190 AS1330Power Consumption < 10 W 19 W nominal, 55 W peakDeviceNet Current Rating 370 mA nominal, 1.0 A peak 800 mA nominal, 2.5 A peakPower Cable 16 / 0.2, Two core screened (shielded) cable or DeviceNet screened (shielded) cable. Voltage 11-25 Vdc (External power supply PSU6024 is available from NDC)Max Supply Level for 40 Vac / Vdc @ 0.5 A Relay Contacts

Analog OutputOutput Impedance <10 ΩOutput Range ±5 V max Output Accuracy Range > 0.1 mm: ± (0.08% of fullscale + 0.4% of reading) Range > 1 mm: ± (0.08% of fullscale + 0.04% of reading) Range > 10 mm: ± (0.08% of fullscale + 0.004% of reading) Range > 100 mm: ± (0.08% of fullscale + 0.0004% of reading)Output Resolution <0.2 mVOutput Update Rate every 2 ms (every 1ms with 1000 scans option)Output Min. Load Resistance 5k Ω

AS1050 AS1100 AS1140 AS1190 AS1330Dimensions 536x142x59.9 mm 682.2x191.9x94.6 mm 990.6x344x130 mm 1326x454x130 mm 2069x689x159 mm (LxHxW) (21.1x5.6x2.36 in.) (26.86x7.56x3.73 in.) (39x13.53x5.13 in.) (52.2x17.87x5.13 in.) (81.48x27.13x6.25 in.)Weight 5 kg (11 lb) 12 kg (26.5 lb) 23 kg (51 lb) 50 kg (110 lb) 125 kg (275 lb)Gate Size 66 mm (2.6 in.) 116 mm (4.6 in.) 152.4 mm (6 in.) 218.4 mm (8.6 in.) 355.6 mm (14 in.)Max Separation 460 mm 457 mm 1016 mm 1570 mm 2702 mm (distance between (18.125 in.) (18 in.) (40 in.) (62.1 in.) (106.4 in.) receiver & transmitter) Airwipe Input 1.38-2 bar 2-2.76 bar Contact Beta LaserMike for details. Pressure (20-30 psi) (30-40 psi)Pressure 9.53 mm (3/8 in.) ID with approx. 6.35 mm (0.25 in.) ID. Tube Size (Tube connects to the filter using a 1/4 NPT 3/8 tube straight fitting LEGRIS 31756014 if needed)

Altitude* Up to 2000 m [6560 ft]Ambient Operating Temp. 5-40°C [41- 104°F]Ambient Storage Temp. -20 to 50°C [-4 to 122°F]Max Relative Humidity 80% for temp. up to 31°C or 88°F (decreasing linearly to 50% relative humidity at 40°C or 104°F)Installation Category* Installation category 2 Pollution Degree* Pollution degree 1 equipment has been designed for operation with a level of pollution of its internal micro-environment, which corresponds with the definition of Pollution Degree 1 in BSEN 61010-1:1993Ingress Protection Rating* IP65 (as defined in BSEN 60529) / NEMA 4Noise < 70 dBa

Environmental

AS1050 AS1100 AS1140 AS1190 AS1330Beam velocity 185,000 mm/s 316,500 mm/s 450,900 mm/s 586,700 mm/s 1309 m/s (500 scans/sec) (7,300 in./s) (12,460 in./s) (17,750 in./s) (23,100 in./s) (51,530 in./s)Type Solid state laser diode. Helium-Neon gas laser. Visible & focused. Wavelength 670 nm. Visible & focused. Wavelength 632.8 nm.Power 10 mW CW max 4 mW CW max (<1 mW peak scanned beam in working area) (<2 mW peak scanned beam in working area)Class Class 2 during operation (Class 3B during servicing i.e. with cover off)

Laser

*Not specified for large gauges

General

OptionsThe AccuScan 1000 series has options that provide enhanced measurement performance and extra connectivity.

Single Scan Flaw Detection: Provides high-speed lump and neck detection. User adjustable thresholds for lumps and necks ........................................................ OEX1530-6256

Fast Analog: High-speed analog output updated after each sample. Designed for use in SRL analysis on datacom core lines ..................................................... OEX1530-7371

Glass Measurement: Provides accurate measurement for transparent and translucent products ......................... OEX1530-7420

STAC Logic: (For stranded, twisted, armored and corrugated product). Provides accurate measurement of non-uniform products such as twisted pair, stranded, armoured, corrugated, etc ............................... OEX1530-7399

Bubble Measurement: Allows gauge to measure in the presence of bubbles or other contaminants on the window that might occur if product to be measured is submerged in water or other fluids............................... OEX1530-6251

1000 scans/sec: High speed product sampling at 1000 samples per second ..........................................................84662

Connection SpecificationsRS232 Connection

General Non Isolated 5 wire port: Rx, Tx RTS, CTS, 0 V. Only 3 wires used for calibration. Full duplex. Baud rates: 4800 – 38400. 1 start, 7 data, 2 stop bits OR 1 start, 8 data, 1 stop bit.Cable Length 15 m (50 ft) for baud rate of 9600 bps. Longer cables may work, but this will depend on capacitance and quality of cable. If problems occur with longer cables, a RS232/RS422 converter box can be purchased from NDC.DTE/DCE Configuration DCE

Network Connection - DeviceNet (option)Cable Length 39 m* (128 ft) at 500 KBps 78 m* (256 ft) at 250 KBps 156 m* (512 ft) at 125 KBps * cumulative distance of branchesData Rate 125/250/500 kbits/s (depends on cable length)Max. Number of Nodes 64

Network Connection - Profibus (option)Cable Length 500 m (1640 ft) at 12 MBps with 4 repeaters (longer cables are possible at a slower data rate and with more repeaters)Data Rate up to 12 MBps (dependent on cable length and repeaters)Max. Number of Nodes 32

AccessoriesAccuScan 1000 accessories give you everything you need for your unique applications:

AS1050 Certified Calibration Fixture .........................................84602

AS1100 Certified Calibration Fixture .........................................84670

AS1140 Certified Calibration Fixture .........................................82332

AS1190 Certified Calibration Fixture .........................................82335

AS1330 Certified Calibration Fixture .........................................84212

AS1050 Air Purge ........................................................................84635

AS1100 Air Purge .........................................................................84729

Light Duty Height Stand .......................................... GA 0042-0029-1/A

Heavy Duty Height Stand ............................................................83961

PSU 6024 Power Supply Unit .................................. GA1530-6965-1/A

PSU 6024 Power Supply Unit (US) ..........................GA1530-6965-2/A

Making Light Work

NDC Technologies is represented in over 60 countries worldwide. www.ndc.com/betalasermike

In line with its policy of continuous improvement, NDC reserves the right to revise or replace its products or services without prior notice. The information contained in this document may not represent the latest specification and is for indicative purposes only.

NDC AmericasTel: +1 937 233 9935Email: [email protected]

NDC United KingdomTel: +44 1621 852244Email: [email protected]

NDC ChinaTel: +86 21 6113 3617Email: [email protected]

NDC SE AsiaTel: +65 91994120 Email: [email protected]

NDC IndiaTel: +91 124 2789507Email: [email protected]

Document #: CT-BROC-SCAN-AccuScan 1000-EN-2017OCT31Date of Issue: October 2017