  • 8/3/2019 ACO ParkDrain Brochure

    1/16

    Next generation of surface drainage

    ACO ParkDrain

    UniclassL7315 + L2123

    EPICJ3413

    CI/SfB

    (52.5)

  • 8/3/2019 ACO ParkDrain Brochure

    2/16

    Optimum solutionACO ParkDrain is a one piece polymer concrete

    drainage system which has been designed as the

    optimum solution for a wide range of surface

    drainage applications requiring Load Class C 250

    installations.

    Lower costsIt has been specifically designed to reduce

    installation time and provide inexpensivemaintenance over its whole life.

    It offers cost advantages for architects, engineers,

    contractors and clients.

    Open-minded innovationACO ParkDrain is the result of over 30 years

    development of innovative surface drainage

    solutions for highways, local authority, retail,

    commercial and domestic users.

    Standards complianceACO ParkDrain has been certificated to Load Class

    C 250 (BS EN 1433:2002) and BS EN 124:1994 for

    gully and access units.

    Contact ACO Technical Department for standards

    details and copies of Load Test certificates.

    Benefits for specifiers

    One piece design means no separate gratingspecifications

    Colour choice to match location - black(asphalt) as standard, other colours availableto order e.g. white and yellow (lines andmarkings), buff/beige (standard paving),red (brick paviours) etc.

    Simplified level and stepped system for quickscheme design

    Benefits for contractors

    Simple scheme layouts with level invert units

    Easy to achieve excellent watertightness(to BS EN 1433:2002) with sealing groove

    Light weight (typically 16 - 20 kg/unit) foreasy one man lift enables compliance withHealth and Safety guidelines

    Benefits for clients

    Integral unit without separate grating styletop eliminates lost or damaged gratings

    Unobtrusive, self-coloured grating maintainsappearance and colour with time

    Rodding access units and sumps with separatelocking resin composite grating, allows easymaintenance

    Resin concrete unaffected by frost

    No removable gratings makes system suitablefor schools and play grounds

    2

    ACO ParkDrain

    THE NEXT GENERATION OF SURFACE DRAINAGE

    Load Class (BS EN 1433:2002)

  • 8/3/2019 ACO ParkDrain Brochure

    3/16

    Introducing

    ACO Mini ParkDrain:ACO Mini ParkDrain is a one piece polymer

    concrete drainage system suitable for applications

    with restricted installation depths. The system is

    suitable for a wide range of drainage applications

    requiring Load Class D 400 installations.

    This system is not designed for highway use where

    it can be trafficked by fast moving vehicles.

    Lower installation costsACO Mini ParkDrain is lightweight and available in

    1 metre length, aiding fast and simple installations.

    Standards complianceACO Mini ParkDrain has been certificated and

    CE marked to Load Class D 400 BS EN 1433:2002.

    Free technical supportTo support architects, engineers and contractors

    in designing and installing ACO ParkDrain and

    ACO Mini ParkDrain schemes, ACOs Design

    Services Team offers computer-aided scheme

    design, hydraulic performance calculations and

    installation advice services.

    Telephone Hotline:

    01462 816666Fax Hotline:

    01462 851081e-mail:

    [email protected]:

    www.aco.co.uk

    Benefits for specifiers

    Shallow system suitable for minimal depthinstallations

    One piece design means no separate gratingspecifications

    Suitable for applications requiring D400installations*

    * Not for highway use.

    Benefits for contractors Lightweight design

    1 metre unit for fast & simple installations

    Easy to achieve excellent water tightness withsealing groove

    Benefits for clients

    Integral drainage solution

    Minimal disruption during installation

    No removable grating makes system suitablefor schools and playgrounds.

    3

    ACO Mini ParkDrain

    FOR RESTRICTED DEPTH INSTALLATIONS

    Load Class (BS EN 1433:2002)

    NEW

  • 8/3/2019 ACO ParkDrain Brochure

    4/16

    4

    ACO ParkDrain

    CHANNEL DRAINAGE

    Resin concrete Minimal lifetime maintenance

    3 - 4 compressive strength of OPC

    (Ordinary Portland Cement), so products

    can be made lighter

    Water absorption < 0.01% by weight*

    * BBA report No. 1580

    Glassre-inforcedconcrete

    Ordinaryconcrete

    Resinconcrete*

    0.5

    1.0

    1.5

    2.0depth

    (mm

    )

    Glassre-inforcedconcrete

    Ordinaryconcrete

    Resinconcrete*

    20

    40

    60

    80

    10

    30

    50

    70

    90100s

    tre

    ngth(N/mm

    2)

    Compressive Strength

    Water Absorption

    Hydraulic choices with ACO ParkDrain*

    1. Constant invert, level ground

    - effective drainage but may need more regularmaintenance due to greater chance of silting.

    2. Constant invert, sloped ground

    - improved hydraulic capacity over system 1.

    3. Stepped invert, level ground

    - will give a similar hydraulic capacity tosystem 2.

    *ACO Mini ParkDrain only available as constant invert

  • 8/3/2019 ACO ParkDrain Brochure

    5/16

    5

    ACO ParkDrain

    CHANNEL RANGE LAYOUT

    PD100C

    306

    PD100C

    123

    PD100C

    20.3

    PD100C

    10.1

    PD100C

    30.1

    PD100C

    15.1

    PD100C

    20.1

    PD100C

    25.1

    PD900C

    PD100C

    208

    PD100C

    108

    PD100C

    308

    PD100C

    10.3

    PD100C

    30.3

    Closing endcap

    Level invert channel

    Step connector

    Inlet/outlet endcap

    Rodding access unit

    Sump unit

  • 8/3/2019 ACO ParkDrain Brochure

    6/16

    ACO ParkDrain is the next generation of surface

    drainage with major advantages in car parks,

    pedestrianised areas and hard-landscaped locations.

    Its one piece design with integral grating means

    it is not vulnerable to vandalism or loosening.

    Rodding Access units and the universal Sump unit

    ensure easy maintenance.

    It is a product especially recommended to be

    used in schools where children play due to its

    monoblock composition it has no removable partswhich could lead to injury.

    Its Load Class C 250 certification means it can be

    deployed in a wide number of locations where

    light vehicle traffic can be expected.

    Its unique colouring means it can either be

    unobtrusively blended with its surroundings - e.g.

    coloured as the adjoining pavement - or used as a

    marker or even signage e.g. coloured white or

    yellow to mark roads. The colour is maintained,

    no rubbing off or being dissolved.

    It is compatible with all types of paving materials,

    and the flat sides enable pavements to be laid

    directly to the units edge.

    ACO Mini ParkDrain

    Complementing the range, ACO Mini ParkDrain is

    specifically designed to provide a drainage solution

    for small drainage areas and applications that have

    restricted depth installation.

    6

    ACO ParkDrain

    INNOVATION IN APPLICATION

  • 8/3/2019 ACO ParkDrain Brochure

    7/16

    7

    ACO ParkDrain

    HYDRAULIC PERFORMANCE TABLES

    Total design flow capacities l/s for each constant depth channel assuming lateral inflow to channel.

    PD100C 10.1 Overall depth = 250mm

    Length to outlet Flow (I/s) Ground slope(m) 0.0% 0.5% 1.0% 1.5%

    5 9.0 10.5 11.7 12.9

    10 8.4 10.9 12.6 14.2

    15 8.1 11.3 13.5 15.1

    20 7.8 11.5 14.0 15.9

    25 7.4 11.7 14.4 16.5

    30 7.1 12.0 14.7 17.1

    40 6.7 12.0 15.0 17.7

    60 6.1 12.0 15.3 18.580 5.6 12.1 15.5 19.2

    PD100C 15.1 Overall depth = 275mm

    Length to outlet Flow (I/s) Ground slope(m) 0.0% 0.5% 1.0% 1.5%

    5 11.1 12.9 14.2 15.4

    10 10.4 13.3 15.4 17.1

    15 10.0 13.6 16.0 18.0

    20 9.6 13.8 16.6 18.8

    25 9.3 14.0 17.1 19.3

    30 8.9 14.1 17.6 20.0

    40 8.3 14.3 18.2 20.6

    60 7.6 14.5 18.4 21.4

    80 7.0 14.7 18.6 22.5

    PD100C 20.1 Overall depth = 300mm

    Length to outlet Flow (I/s) Ground slope(m) 0.0% 0.5% 1.0% 1.5%

    5 13.5 15.5 17.1 18.2

    10 12.6 15.8 18.1 19.7

    15 12.0 16.1 18.8 20.9

    20 11.3 16.3 19.4 21.9

    25 10.9 16.4 20.1 22.8

    30 10.4 16.5 20.6 23.7

    40 9.8 16.7 21.0 24.5

    60 9.2 16.8 21.3 25.5

    80 8.5 17.0 21.7 26.6

    PD100C 25.1 Overall depth = 325mm

    Length to outlet Flow (I/s) Ground slope(m) 0.0% 0.5% 1.0% 1.5%

    5 16.1 18.2 19.9 21.4

    10 15.1 18.4 21.0 22.7

    15 14.3 18.6 21.8 24.0

    20 13.6 18.8 22.3 25.1

    25 13.0 19.0 22.7 25.9

    30 12.4 19.1 23.1 26.7

    40 11.7 19.2 23.6 27.4

    60 11.0 19.2 24.1 28.280 10.1 19.4 24.8 28.6

    PD100C 30.1 Overall depth = 350mm

    Length to outlet Flow (I/s) Ground slope(m) 0.0% 0.5% 1.0% 1.5%

    5 18.9 21.1 22.9 24.6

    10 17.9 21.2 24.1 26.3

    15 17.0 21.4 24.8 27.6

    20 16.2 21.6 25.3 28.5

    25 15.4 21.6 25.8 29.4

    30 14.6 21.7 26.2 30.1

    40 13.8 21.7 26.7 30.9

    60 12.1 21.8 27.2 31.7

    80 11.8 21.9 27.9 32.1

    PD100C 10.1/PD100C 15.1/

    PD100C 20.1/PD100C 25.1/PD100C 30.1

    Length to outlet Flow (I/s) Ground slope(m) 0.0% 0.5% 1.0% 1.5%

    5 25.6 25.6 26.4 26.8

    10 24.7 25.6 25.7 26.2

    15 23.3 25.2 25.3 25.9

    20 20.3 24.0 25.0 25.9

    25 16.9 22.0 24.9 25.9

    30 13.5 20.7 24.8 26.0

    Total design flow capacities in I/s for a stepped

    channel system assuming equal numbers of

    each height of channel are used with step

    transition channels.

    Note: Refer to ACO Technical Handbook and Design Guide for further hydraulic details.

  • 8/3/2019 ACO ParkDrain Brochure

    8/16

    Maximum total flow capacities (l/s) for each constant depth channel, assuming lateral inflow to the channel

    ACO Mini ParkDrain Overall depth = 125mm

    Length to outlet Flow (I/s) Ground slope(m) 0.0% 0.5% 1.0% 1.5%

    5 1.4 1.9 2.2 2.5

    10 1.3 2.0 2.4 2.6

    15 1.2 2.1 2.5 2.7

    20 1.1 2.2 2.6 2.8

    25 1.1 2.3 2.7 2.9

    30 1.0 2.4 2.8 3.0

    35 1.0 2.4 2.8 3.1

    40 0.9 2.5 2.9 3.2

    The maximum catchment depth drained by the

    channel may be derived from the tables.

    For total flow Q (l/s); Catchment Depth CD (m);

    Length of channel to outlet Lo (m); Rainfall

    intensity i (l/s/m2)

    Then Q = CD x Lo x i. Hence CD = Q / (Lo x i)

    8

    ACO Mini ParkDrain

    HYDRAULIC PERFORMANCE TABLES

  • 8/3/2019 ACO ParkDrain Brochure

    9/16

    9

    ACO Mini ParkDrain

    PARTS TABLE

    Channels

    Dimensions (mm) Connections Availability

    Depth Weight Closing

    Description Order No. Overall Invert Length (kg) Sumps Endcaps

    Mini ParkDrain 30125 125 105 1000 24.7 PD900C Mini ParkDrain 306

    closing end cap

    Access unit

    Dimensions (mm) Connections Availability

    Depth Weight Closing

    Description Order No. Overall Invert Length (kg) Sumps Endcaps

    Mini ParkDrain access 31253 125 105 1000 28.5 PD900C Mini ParkDrain 306

    closing end cap

    End cap

    Dimensions (mm) Wide Weight

    Description Order No. Depth Overall Invert Bore Overall Length (kg)

    Mini ParkDrain 306 closing end cap 30306 305 - - 150 25 2.5

    1000mm105mm

    125mm

    150mm

    1000mm1

    05mm

    1

    25mm

    150mm

    25mm

    305mm

    150mm

    Access unit has performed 110mm knockout under access cover for vertical outlet

  • 8/3/2019 ACO ParkDrain Brochure

    10/16

    10

    ACO ParkDrain

    PARTS TABLE

    Note: As with all pre-cast products, polymer concrete units are subject to weight and dimensional tolerances.

    Channels

    Dimensions (mm) Connections Availability

    Fall Type Depth Weight Endcaps Step

    Description Order No. Level Sloped Overall Invert Length (kg) Sumps Closing Inlet/outlet Connector

    PD100C 10.1 30101 L - 250 225 500 16.3 PD900C PD100C 306 PD100C 108 -

    PD100C 15.1 30151 L - 275 250 500 17.3 PD900C PD100C 306 - -

    PD100C 20.1 30201 L - 300 275 500 18.3 PD900C PD100C 306 PD100C 208 PD100C 123

    PD100C 25.1 30251 L - 325 300 500 19.3 PD900C PD100C 306 - -

    PD100C 30.1 30301 L - 350 325 500 20.3 PD900C PD100C 306 PD100C 308 PD100C 123

    150mm 100mm500mm

    250-3

    50mm

    Channel

  • 8/3/2019 ACO ParkDrain Brochure

    11/16

    11

    ACO ParkDrain

    PARTS TABLE

    PD100C Rodding access/junction unit

    Dimensions (mm) Connections Availability

    Fall Type Depth Weight Endcaps Step

    Description Order No. Level Sloped Overall Invert Length (kg) Sumps Closing Inlet/outlet Connector

    PD100C 10.3 30103 L - 250 225 500 13.0 PD900C PD100C 306 PD100C 108 -

    PD100C 20.3 30203 L - 300 275 500 15.0 PD900C PD100C 306 PD100C 208 PD100C 123

    PD100C 30.3 30303 L - 350 325 500 17.0 PD900C PD100C 306 PD100C 308 PD100C 123

    Endcaps

    Dimensions (mm)

    Depth Width Weight

    Description Order no. Overall Invert Bore Overall Length (kg)

    PD100C 306 Closing 30306 350 - - 150 25 2.5

    PD100C 108 Inlet/outlet 30108 250 225 100 150 25 1.5

    PD100C 208 Inlet/outlet 30208 300 275 100 150 25 1.8

    PD100C 308 Inlet/outlet 30308 350 325 100 150 25 2.1

    Step connector

    Dimensions (mm)

    Depth Width Weight

    Description Order no. Overall Invert Bore Overall Length (kg)

    PD100C 123 Step connector 30123 - 50 94 150 123 0.9

    105mm

    150mm150mm

    350m

    m

    25mm

    110mm

    25mm

    Closing endcap inlet/outlet endcap

    Step connector

    Rodding Access/Junction unit can be inserted between Constant Depth units with matching overall/invert depths.

    110mm

    150mm 100mm500mm

    250-3

    50mm

    Rodding access/junction unit

  • 8/3/2019 ACO ParkDrain Brochure

    12/16

    Sump unit

    Dimensions (mm)

    Depth Width Weight

    Description Order no. Overall Invert Bore Overall Length (kg)

    PD900 C Standard sump unit 30900 665 640 100 150 500 35

    Foul air traps

    Dimensions (mm)

    Depth Width Weight

    Description Order no. Overall Invert Bore Overall Length (kg)

    920 Foul air trap PVC-U 110mm 2640 - 395 100 110 - 0.5

    922 Foul air trap PVC-U 160mm 2638 - 375 150 160 - 1.9940 Roddable foul air trap MDPE 110mm 7931 - 480 100 110 - 0.6

    950 Roddable foul air trap MDPE 160mm 7932 - 435 150 160 - 0.8

    Dimensions (mm)

    Depth Width Weight

    Description Order no. Overall Invert Bore Overall Length (kg)

    820 Drain union PVC-U 110mm 0056 - - 100 110 100 0.1

    822 Drain union PVC-U 160mm 0058 - - 150 160 150 0.5

    12

    ACO ParkDrain

    PARTS TABLE

    500mm

    665mm

    640

    mm

    480mm

    640mm 3

    80mm

    395mm

    920 Foul air trap

    PVC-U 110mm

    950 Roddable

    foul air trap

    MDPE 160mm

    435mm

    13.1

    l/s

    30.1

    l/s

    940 Roddable

    foul air trap

    MDPE 110mm

    480mm

    14.6

    l/s

    922 Foul air trap

    PVC-U 160mm

    375mm

    27.4

    l/s

    Sump unit

    820 Drain union

    PVC-U 110mm

    822 Drain union

    PVC-U 160mm

    * Sump unit knockouts suit Constant Depth unit depths as indicated in the product table. ACO sump units allow two way drainage unitconnection with discharge to sub-surface drainage.

    Note: See product table to matching inlet/outlet endcap with correct drainage unit. Outlet endcaps aresupplied as two components to be site assembled to suit flow direction.

  • 8/3/2019 ACO ParkDrain Brochure

    13/16

    13

    ACO ParkDrain & ACO Mini ParkDrain

    SITEWORK INSTALLATION

    1.0 Ground Conditions

    The customer should ensure thatthe minimum dimensions shownare suitable for the existingground conditions. Engineering

    advice may be necessary.

    2.0 Block Pavements

    The channel must be supportedlaterally and therefore blocks

    must be restrained frommovement by bedding securelye.g. by using a Polymer ModifiedMortar for bed and perpendicularjoints (for example RONAFIXMortar Mix C from Ronacrete: Tel01279 638 700). Engineering

    advice may be required.

    3.0 Surface Cracks

    Alternate crack control andmovement joints transverselywithin bed and haunch may

    reduce unsightly surface cracking.

    4.0 Joint Sealant

    Where ACO Drain channel jointsand fittings are to be sealed(where used in foul waterapplications or whereimpermeability is required)contact a sealant specialist forguidance on the most appropriatesealing compound to use.

    5.0 Surface Protection

    In asphalt pavements avoidcontact between compactionequipment and channel/grating.This may be achieved by ensuringthat the finished surface level liesabove the grating level (by atleast 3mm) Stones should beremoved prior to laying/rollingwearing course.

    ACO ParkDrain

    (To Load Class C 250)

    ACO Mini ParkDrain

    (To Load Class D 400)

    Note: For ACO Mini ParkDrain

    installations to Load Class C 250,the minimum concrete bed andsurround may be reduced to150mm.

    Asphalt pavement

    150mm

    150mm

    Top of haunch 25mm maximumbelow wearing course.

    Concrete bedand haunchminimum compressivestrength 25 N/mm2

    See Note 5.0

    Concrete pavement

    150mm

    150mm

    Note: Movement joint to

    Engineers detail

    Concreteslab

    Concrete bedand haunchminimum compressivestrength 25 N/mm2

    Block pavement

    150mm

    150mm

    150mm

    Block

    Concrete bedand haunchminimum compressivestrength 25 N/mm2

    Asphalt pavement

    Minimum200mm

    See Note 5.0

    Minimum

    200mm

    Concrete bedand haunchminimumcompressivestrength

    25N/mm2

    Concrete pavement

    Minimum200mm

    Note: Expansion joint toengineers detail

    Minimum

    200mm

    Concretebed andhaunchminimumcompressivestrength25N/mm2

    Concreteslab

    Concreteslab

    Block pavement

    Minimum200mm

    Note: Block bedded usingmortar (see note 2.0)

    Option 1 Option 2

    Block Block

    Minimum2

    00mm

    Approx 225mm

    Concretebed andhaunchminimumcompressivestrength25N/mm2

  • 8/3/2019 ACO ParkDrain Brochure

    14/16

    ACO ParkDrain

    Model Specification ClauseThe surface drainage system shall be as

    ACO ParkDrain channels as supplied by ACO

    Technologies plc; all materials and components

    within the scope of this system shall be obtained

    from this manufacturer. The system shall be

    certified to BS EN 1433:2002 Load Class C 250 and

    BS EN 124:1994 for the access and gully unit

    covers; load test certificates shall be supplied to the

    Supervising Officer.

    The system shall be of units 500mm long, 100mm

    nominal internal width, 150mm external width,

    one piece manufacture in polyester resin concrete,

    with integral resin concrete grating featuring 8mm

    wide downward flared inlet slots to ACO registered

    pattern providing a minimum inlet area of

    18,300mm2 per metre.

    The standard units shall be installed with the

    manufacturers level invert and transitional sloping

    invert units, rodding access, sump and accessories

    as required for the scheme.

    The system shall be installed in accordance with

    the manufacturers printed recommendations, and

    the work carried out as specified on the

    Supervising Officers drawing no.* and in

    accordance with recognised good practice.

    Standards of workmanship shall generally be as

    specified in BS EN 752:2008 and BS 8000:Part

    14:1989.

    * Please insert drawing no. relevant to the project.

    14

  • 8/3/2019 ACO ParkDrain Brochure

    15/16

    15

    ACO Mini ParkDrain

    Model Specification ClauseThe surface drainage system shall be as ACO Mini

    ParkDrain channels as supplied by ACO

    Technologies plc; all materials and components

    within the scope of this system shall be obtained

    from this manufacturer. The system shall be

    certified to BS EN 1433:2002 Load Class D 400

    and BS EN 124:1994 for the access and gully unit

    covers; load test certificates shall be supplied to the

    Supervising Officer.

    The system shall be of units 1000mm long,

    100mm nominal internal width, 150mm external

    width, one piece manufacture in polyester resin

    concrete, with integral resin concrete grating

    featuring 8mm wide downward flared inlet slots to

    ACO registered pattern providing a minimum inlet

    area of 18,300mm2 per metre.

    The standard units shall be installed with the

    manufacturers level invert units, rodding access,

    sump and accessories as required for the scheme.

    The system shall be installed in accordance with

    the manufacturers printed recommendations, and

    the work carried out as specified on the

    Supervising Officers drawing no.* and in

    accordance with recognised good practice.

    Standards of workmanship shall generally be as

    specified in BS EN 752:2008 and BS 8000:Part

    14:1989.

    * Please insert drawing no. relevant to the project.

    Technical Support ServicesTo support architects, engineers and contractors in designing and installing ACO ParkDrain schemes,

    ACOs Design Services Department offers computer-aided scheme design, hydraulic performance

    calculations and installation advice services.

    Our Telephone Hotline 01462 816666, Fax Hotline 01462 851081, e-mail [email protected] andwebsite www.aco.co.uk enable us to give you the response you need.

  • 8/3/2019 ACO ParkDrain Brochure

    16/16

    ACO Technologies plc

    ACO Business Park,

    Hitchin Road,

    Shefford,

    Bedfordshire

    SG17 5TE

    Tel: 01462 816666

    Fax: 01462 815895

    e-mail Sales: [email protected]

    e-mail Technical: [email protected]

    website: www.aco.co.uk

    March 2010 ACO Technologies plc. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guarantee since the

    conditions of use are beyond the control of the Company. It is the customer's responsibility to ensure that each product is fit for its intended purpose, and that the actual conditions of use are suitable. This brochure and any advice is

    provided by ACO Technologies plc (the Company) free of charge and accordingly on terms that no liability including liability for negligence will attach to the Company or its servants or agents arising out of or in connection with or in

    relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company's policy of continuous product

    development and improvement renders specifications liable to modification. Information provided in this brochure is therefore subject to change without prior notification.

    ACO CARES ABOUT THE ENVIRONMENT

    Printed on material approved by the Forest Stewardship Council (FSC) who provide a means of assuring that products come from sustainably managed forests.