aco technical data sheets engineered systems v1
DESCRIPTION
http://www.acobuildingdrainage.co.uk/media/9968/ACO-Technical-Data-Sheets-Engineered-Systems-V1.pdfTRANSCRIPT
![Page 1: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/1.jpg)
Variable
Variable
Up to 3000 Maximum length as standard
29
Varia
ble
2
30 15 10
Varia
ble
Drainage holes (Optional)
30
^pNMN=am`=`Ü~ååÉä
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 2: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/2.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pNMN=am`=`Ü~ååÉä
� Provides drainage to DPC
� Bonding flange or clamp flange options
� Can be modelled hydraulically to preventbackflow to DPC
� Grades 304 or 316
![Page 3: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/3.jpg)
Up to 3000 Maximum length as standard
29
Variable
Variable
66 min
2
^pOMN=jÉÅÜ~åáÅ~ä=`ä~ãé
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 4: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/4.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pOMN=jÉÅÜ~åáÅ~ä=`ä~ãé
� Used where ACO Vinyl Seal cannot beused, for example when flexible floor isnon-weldable or when high temperaturedischarges are likely
� Clamps most flexible floor materials
� Up to 8mm floor material thickness
� Grades 304 or 316
![Page 5: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/5.jpg)
60
29
Variable
40 to 300
Variable
1015 15
Up to 3000 Maximum length as standard
2
^pPMN=_çñ=`Ü~ååÉä
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 6: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/6.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pPMN=_çñ=`Ü~ååÉä
� Standard channel profile
� Suited to internal and external application
� Wide choice of standard gratings
� Standard and high security lockingavailable
� Interfaces with ACO Vinyl Seal
� Grades 304 or 316
![Page 7: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/7.jpg)
Up to 3000 Maximum length as standard
29
192
250
10
31
Variable
2
AS401 Fire Lift Channel
ACO Bespoke DrainageStainless Steel Systems
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
Building Drainage
![Page 8: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/8.jpg)
ACO Building Drainage A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]
AutoCad drawings available to download on the website.
AS401 Fire Lift Channel
� Up to 25 l/s capacity (2 x 160 diameter outlets)
� Designed and hydraulically modelled toyour specifications
� Channel conforms to BS 9999: 2008 code of practice for fire safety in the design,management and use of buildings
� Grades 304 or 316
� Can be designed for carpet or flexibleflooring
� Floor structure must accomodate deepchannel depth
Building Drainage
![Page 9: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/9.jpg)
Up to 3000 Maximum length as standard
29
Variable
Variable10
Variable
^pRMN=b~ëóJ`äÉ~å
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 10: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/10.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pRMN=b~ëóJ`äÉ~å
� Radius base profile
� Minimises debris build up
� Ideal for food processing or any area wherehygiene is a prerequisite
� Interfaces with ACO Vinyl Seal
� Grades 304 or 316
![Page 11: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/11.jpg)
Up to 3000 Maximum length as standard2920
10
60 to 120
50
2
^pSMN=päçí=`Ü~ååÉä=ïáíÜ=qçÉÄ~ê
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 12: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/12.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pSMN=päçí=`Ü~ååÉä=ïáíÜ=qçÉÄ~ê
� Toebar reduces slot width to 5mm slots forbare foot or heelsafe area applications
� Interfaces with ACO Vinyl Seal
� Low capacity drainage areas
![Page 13: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/13.jpg)
Up to 3000 Maximum length as standard2920
10
60 to 120
50
2
^pSMN=päçí=`Ü~ååÉä
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 14: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/14.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pSMN=päçí=`Ü~ååÉä
� Discrete slot channel
� Visible width 50mm
� Slot 20mm
� Interfaces with ACO Vinyl Seal
� Grades 304 or 316
� Pedestrian load class
![Page 15: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/15.jpg)
Up to 3000 Maximum length as standard
Variable
Variable
Variable
10
15
1550
29
2
^pTMN=réëí~åÇ
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 16: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/16.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pTMN=réëí~åÇ
� Ideal for areas where a wall tanking isrequired
� Integrates with tiled walls
� Ideal for public shower areas
� Grades 304 or 316
![Page 17: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/17.jpg)
Up to 3000 Maximum length as standard
29
10
60 to 120
82
15 15
^pUMN=jáÅêç=`Ü~ååÉä
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 18: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/18.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pUMN=jáÅêç=`Ü~ååÉä
� 82mm wide discrete channel
� Bespoke grating patterns to suit
� Suited to low flow applications
� V-Profile to assist debris removal
� Interfaces with ACO Vinyl Seal
� Grades 304 or 316
![Page 19: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/19.jpg)
10
29
Up to 3000 Maximum length as standard
10
Variable
Variable
Dependent on load class
Variable
2
^pVMN=eá=iç~Ç
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 20: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/20.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pVMN=eá=iç~Ç
� Extended grating seat depth and width
� For high load applications for up to LoadClass E
� Grades 304 or 316
![Page 21: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/21.jpg)
Up to 3000 Maximum length as standard
Variable
Variable
3
58
Variable
Variable(stone plus bedding)
^pNMMN=aáëÅêÉíÉ=`Ü~ååÉä
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 22: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/22.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pNMMN=aáëÅêÉíÉ=`Ü~ååÉä
� 50mm wide channel throat providescleaning jet access
� Conventional bore for high capacity
� Heel safe gratings for safety and enhancedaesthetics
� Grades 304 or 316
� Available radius version
� Ideal for external prestige applications
![Page 23: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/23.jpg)
230 to 530
530 to 3030
Outlet location variable
Variable
10
230 to 530
15 15
50 to 3002
^pOMMN=háíÅÜÉå=`Ü~ååÉä
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth is greater than channel bore then a ‘V’ bottom will be incorporated.
All dimensions are in mm.
![Page 24: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/24.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pOMMN=háíÅÜÉå=`Ü~ååÉä
� High water Interception capacity
� Optional built in fall
� Compatible with gully base units
� Grades 304 or 316
![Page 25: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/25.jpg)
3000 Maximum length
Low level drainage slots
Variablebuild height
10
15515 15
^pPMMN=aì~ä=iÉîÉä=aê~áå~ÖÉ=`Ü~ååÉä
^`l=_ÉëéçâÉ=aê~áå~ÖÉpí~áåäÉëë=píÉÉä=póëíÉãë
Please Note: If channel depth isgreater than channel bore then a ‘V’bottom will be incorporated.
All dimensions are in mm.
![Page 26: Aco technical data sheets engineered systems v1](https://reader035.vdocument.in/reader035/viewer/2022081722/568ca6681a28ab186d912647/html5/thumbnails/26.jpg)
^`l=_ìáäÇáåÖ=aê~áå~ÖÉ A division of ACO Technologies plc
ACO Business Centre, Caxton Road, Bedford, Bedfordshire MK41 0LFTel: 01462 816666 Fax: 01462 851490 e-mail: [email protected]ïïïK~ÅçÄìáäÇáåÖÇê~áå~ÖÉKÅçKìâ
AutoCad drawings available to download on the website.
^pPMMN=aì~ä=iÉîÉäaê~áå~ÖÉ=`Ü~ååÉä
� Integrated surface and land drainage
� Perforated side walls allows water ingressat low level
� Requires geotextile membrane
� Grades 304 or 316