13
©2011 Waters Corporation 1 ACQUITY UPLC Systems with 2D Technology Solves Key Challenges Increase Selectivity & Sensitivity Eliminate Unwanted Interferences Mobile Phase Flexibility Characterize the Most Complex Samples

Upload: others

Post on 15-Mar-2022

7 views

Category:

Documents


1 download

TRANSCRIPT

©2011 Waters Corporation 1

ACQUITY UPLC Systems with 2D Technology Solves Key Challenges

Increase Selectivity & Sensitivity

Eliminate Unwanted

Interferences

Mobile Phase Flexibility

Characterize the Most Complex Samples

©2011 Waters Corporation 2

Complicated and Difficult to Operate Customer Enabled 2D System

©2011 Waters Corporation 3

Simple to Use and Easy to Implement, Robust ACQUITY UPLC with 2D Technology

©2011 Waters Corporation 4

All ACQUITY UPLC Systems 2D Capable New Systems and Upgrades Shipping Now

ACQUITY UPLC H-Class & Bio System with 2D Technology

ACQUITY UPLC I-Class System with 2D Technology

ACQUITY UPLC System with 2D Technology

©2011 Waters Corporation 5

Trapping — Increase Sensitivity by Loading

More Sample

Heart Cutting — Increase Resolution by

Incorporating Orthogonal Chemistries

At-Column Dilution (ACD) — Enables Large Volume Injections

of Samples in Strong Solvent

Parallel Column Regeneration — Increase Throughput

Designed for Four Functions

©2011 Waters Corporation 6

Filter Trapping of Phospholipids

desired peptides (co-eluting)

phospholipids interference

Typical LC Separation ACQUITY UPLC with 2D Technology

desired peptides

no phospholipids

Data Generated by PPD Inc.

©2011 Waters Corporation 7

Customer Success Utilizing 2D LC

PPD in Richmond, VA has over 50 LC/MS/MS Instruments all Performing 2D LC

80% of the 2D LC Analysis are “Filter” Trapping for Phospholipid removal

—Provided 25-50% Increase in Column Lifetime

“The ability to perform two dimensional UPLC separations using Waters technology has enabled some of our most challenging assays that require ultra-high sensitivity while maintaining excellent ruggedness and instrument up-time.“

- Rand Jenkins, PPD

©2011 Waters Corporation 8

2D for Heart Cutting

Blank 100pg/mL

©2011 Waters Corporation 9

2 Dimensional Dried Blood Spot Analysis of Rosuvastatin by At Column Dilution

No “At Column Dilution” With “At Column Dilution”

• Direct injection of methanol extract from DBS sample • 80uL injection of methanol • At column dilution

©2011 Waters Corporation 10

Application Information

Waters Posters — Biopharma

o Quantitation and MS Analysis of Monoclonal Antibodies in a Complex Mixture

— Bioanalysis

o Eliminate Dry Down and Reconstitution, Increase Sensitivity and Elimination of Interferences with Heart Cutting and At-Column Dilution Analysis of Dried Blood Spot Samples

Customer Generated Material

©2011 Waters Corporation 11

Trapping Installation Test Created for Installation and Support

2D UPLC System Installation Test — Perform Standard System Installation Test

— Perform 2D System Installation Test for Trapping and Elution

o Analyze % Recovery 2D Compared to 1D

2D Training Classes Available on Portal

©2011 Waters Corporation 12

Software compatibility

For the moment only supported in Mass Lynx

©2011 Waters Corporation 13

2D UPLC Systems and Upgrades are Shipping Now

MassLynx Software version 4.1

I-Class 2D Part Numbers

ACQUITY UPLC 2D Upgrade Part Numbers

P/N Description Components

176015076 I-Class FTN with 2x BSM FTN, BSM, BSM and CM-A

176015077 I-Class FTN with QSM/BSM FTN, QSM, BSM and CM-A

P/N Description Components

176002491 ACQUITY UPLC 2D Upgrade BSM and CM-A