actix cellopt afp release notes 3.14.15
TRANSCRIPT
Version 3.14.15
AFP Release Notes
Actix Cellopt AFP Release Notes for Version 3.14.15
2
1 New features
1.1 What‟s new in Cel lopt AFP 3.14.14 - 3.14.15
No new features have been added.
1.2 What‟s new in Cel lopt AFP 3.14.13
1.2.1 Import of P lanet 5 .4.0.226 projects
The import of Planet 5.4.0.226 projects is supported for GSM and iDEN. Hence, the
Planet versions supported for importing are 5.3.2.x - 5.4.0.226.
1.3 What‟s new in Cel lopt AFP 3.14.12
1.3.1 New import of P lanet 5 .3 projects
GSM and iDEN projects can now be imported directly from Planet 5.3 projects
(<projectname>.planet.dat).
1 .3.2 Layer ass ignment for rad ios in Quads
Now the user is able to set all the layers of a Quad's radio to the other radios of
that Quad by one assignment.
1.4 What‟s new in Cel lopt AFP 3.14.11
1.4.1 New format for import of projects and p lans
GSM projects and plans can now be imported from RANX 3 files in order to allow
data exchange between Actix applications.
1.5 What‟s new in Cel lopt AFP 3.14.10
1.5.1 Support of Excel 2007 format for Rad io Edi tor reports
In addition to the previously supported formats (Tab delimited in .txt files, pre-
2007 Excel format in .xls files), the Radio Editor report can now be saved to files in
the Microsoft Excel 2007 workbook format (Office Open XML, .xslx files). This
allows the export of Radio Editor tables with more than 32768 rows.
Actix Cellopt AFP Release Notes for Version 3.14.15
3
1.6 What‟s new in Cel lopt AFP 3.14.9
1.6.1 New format for export of p lans
Plans of GSM projects can now be exported to the RANX 3 format.
1 .6.2 Support for operat ing systems added
Windows 7 64-bit with Service Pack 1 is now supported.
Windows Server 2008 R2 (used as Citrix server) is now supported.
1.7 What‟s new in Cel lopt AFP 3.14.8 & 3.14.7
There are no new features available in these versions.
1.8 What‟s new in Cel lopt AFP 3.14.6
1.8.1 New technology (TETRA) added
TETRA networks can now be modelled by AFP. TETRA is similar to LMR in that it is a
technology wherein intermodulation products can be calculated and included in the
analysis, optimisation and manual retune of networks. It differs significantly in that
uplink and downlink frequencies cannot be modelled separately, but rather one
channel number corresponds to two frequencies (Tx and Rx) which are separated
by a fixed distance.
In order to meet TETRA requirements, intermodulation products can now be
calculated as high as the 11th order.
1 .8.2 Export o f l ayer -based forb idden f requenc ies to the Asset
p lanning too l i s now opt ional (SF50236)
The exporting of forbidden frequencies attached to layers was causing issues with
some versions of Asset when the plan exported from AFP was reimported into
Asset. As the frequencies were not required in Asset, an option has been included
in the plan export to allow them to be omitted from the Asset export.
1.9 What‟s new in Cel lopt AFP 3.14.4
1.9.1 Warn ing when import ing project f i l e (SF52102)
A new warning has been added when a user attempts to import a Cellopt3 format
project file when a project is already open in AFP. This will help prevent the
inadvertent overwriting of data.
1 .9.2 Removed a l l references to Color Code for LMR (SF52100)
As LMR technology does not use color codes, all references to color code are hidden
when LMR technology is selected.
Actix Cellopt AFP Release Notes for Version 3.14.15
4
1.10 What‟s new in Cel lopt AFP 3.14.3
1.10.1 Better support fo r Rx/Tx band spl i t i n LMR technology
(SF52101)
It is now possible to specify a minimum Tx and a maximum Rx frequency for the
available spectrum on the spectrum page to create a Tx/Rx band split. When these
settings are applied, Cellopt AFP automatically applies an appropriate range of
forbidden frequencies to the category Radio Use and Tx/Rx Layers.
1 .10.2 Flex ib le opt ion for imput ing Adj ru les (SF53080)
The dropdown menu for selecting Adj rules has been changed to an edit box in
order to allow users to be able to enter desired values for creating Adj rules.
1.11 What‟s new in Cel lopt AFP 3.14.2
1.11.1 Opt ion to change database password (SF50847)
When AFP is installed, a MySql database is created with default passwords. A new
option has been added to the Control Panel Options screen so that the password
can be changed if desired.
1.12 What‟s new in Cel lopt AFP 3.14.1
There are no new features available in this version.
1.13 What‟s new in Cel lopt AFP 3.14.0
1.13.1 Frequency opt imisat i on for LMR networks (SF51822)
Cellopt AFP has been extended to support frequency optimisation and reduce
intermodulation interference for LMR (Land Mobile Radio) networks. A new LMR
technology support has been added to the list of available (GSM, iDEN, TDMA &
PDC) technologies for projects.
LMR networks have two sectors each site and transmit (Tx) and receive (Rx) radio
channels on separate sectors. This can be modelled in AFP by assigning these
radios to a new LMR-specific system category (Radio Use). During optimisation
intermodulation products can be calculated and used in frequency analysis,
optimisation and retune to reduce overall intermodulation interference in the
network. Separate penalties can be set up for 3rd, 5th and 7th-order products, and
for Co and Adj rules within the same order.
As well as feeding in automatically to the frequency optimisation and retune to
enable the plan to avoid channels with intermodulation products, a detailed report
is available showing how the products are calculated and identifying the offending
Tx channels.
Actix Cellopt AFP Release Notes for Version 3.14.15
5
1.14 What‟s new in Cel lopt AFP 3.12.10
1.14.1 New warn ing for MCRB rad io assignments (SF45971)
A new project warning has been added when MCRBs are assigned more than six
radios. This reflects the actual limit in the field. If more than six radios are assigned
to MCRBs when performing analysis or optimization a warning would be displayed
that this is not supported and radios would be treated as normal radios.
1 .14.2 Conf igurable Path fo r database Locat ion (SF49170)
A new dialog has been added in setup process to allow user to choose db location
during installation process. User would be allowed to choose a new database
location only for new installations. During upgrade database location cannot be
changed.
1.15 What‟s new in Cel lopt AFP 3.12.8 & 3.12.9
There are no new features – these releases are dedicated to resolving issues found
in the product. See Issues resolved in 3.12.8 & 3.12.9.
1.16 What‟s new in Cel lopt AFP 3.12.7
1.16.1 „Enab le a l l Radios ‟ but ton (SF43866)
A new feature has been added that would allow a user to enable multiple radios
with a single click. A button has been added at the bottom of the Network page to
enable all radios in the network.
Icons have been added to the Site and Sector Property pages to allow a user to
enable all radios for a site and sector, displayed in the Property page.
To avoid radios becoming inadvertently enabled, a dialog is presented to the user
to confirm the action.
1.17 What‟s new in Cel lopt AFP 3.12.6
1.17.1 Ci t r i x support (SF47764, 47779, 47819)
It is now possible to install and run Cellopt AFP on a Citrix server.
Actix Cellopt AFP Release Notes for Version 3.14.15
6
1.18 What‟s new in Cel lopt AFP 3.12.5
1.18.1 Use ex i st ing database when insta l l ing maintenance
re leases (SF47021)
When installing maintenance releases, the Cellopt installer has been configured to
use the existing database.
1 .18.2 Select radios in the ed i tor f rom the warn ing (SF46219)
A new feature has been added to allow the user to select the radios that are
contributing to a warning.
1.19 What‟s new in Cel lopt AFP 3.12.4
1.19.1 System category „OLD COLOR CODE‟
A new system category has been added which can be applied to radios. The user
can now update the „Old Color Code‟ column in the Radio Editor, and these values
will be saved in the database.
1 .19.2 Spectrum warn ing
A new warning has been added for situations when all sets break available
separation rules for particular radios. This would help in explaining when the
optimizer and analyzer scores are significantly different.
1.20 What‟s new in Cel lopt AFP 3.12.3
1.20.1 Increased channel separat ion l imi t
Additional channel separation for Adj-120 and Adj-240 has been provided in
addition to current settings of Adj-1 to Adj-21.
1.21 What‟s new in Cel lopt AFP 3.12.2
1.21.1 GRFU feature development
A new feature has been developed to support GRFU channels (GSM Radio
Frequency Unit). It is an extension to the existing support for GSM maximum
separation groups.
1 .21.2 Sector-based tab-del imi ted export data f rom the Rad io
Ed i tor
A new feature has been developed to allow Radio Editor data to be exported in
sector-based tab-delimited format. This complements the tab-delimited file format
feature developed for AFP 3.12 to create a new project or modify an existing
project.
Actix Cellopt AFP Release Notes for Version 3.14.15
7
1.21.3 Defau l t report dest inat ion
A new option has been added to set an analysis report‟s default destination to be a
file rather than the screen. The default directory location is stored in Options.
1 .21.4 Layer sort ing
Layers defined by the user will appear in alphanumeric order; however, system
layers will maintain their current, logical order.
1.22 What‟s new in Cel lopt AFP 3.12.1
1.22.1 Tab del imi ted import improvement
Tab delimited file import has been improved to allow the enabling/disabling of
radios by specifying values for a whole sector or a single radio.
1 .22.2 Warn ings i f unusable p lan i s created
If Cellopt AFP encounters a problem when updating radios with the results of a
frequency optimization, a warning is now produced about the unassigned radios,
allowing the user to take remedial action.
1.23 What‟s new in Cel lopt AFP 3.12
1.23.1 Enhanced sort ing in Radio Edi tor
Sorting in Radio Editor and in all other reports has been improved to sort numbers,
embedded in names, in numerical order instead of alphabetical order.
1 .23.2 Tab del imi ted format import
Using this format, a new project can be created or an existing project can be
modified. Values are defined per sector, per line, and can be used to create/modify
various elements in the project, e.g. sectors, radios, categories, layers. It can also
be used to create neighbor relations.
For more information about this format and how to create it, please refer to the
Cellopt AFP User Guide.
1 .23.3 Move sectors between s i tes
Sectors can easily be moved between sites from the network tree. The sector will
keep its entire configuration, including the attached radios.
1 .23.4 Java 6.0 support
Support for Java 6.0 was added in order to become compliant with Aero on
Windows Vista. The Aero GUI does not support the older Java 5.0.
Actix Cellopt AFP Release Notes for Version 3.14.15
8
1.23.5 Common Act i x l i cens ing
The licensing system has changed. The new system will be common within all Actix
software. Currently Actix Analyzer and Cellopt AFP/MDA and Actix Switch Adapter
use the same licensing.
For older versions of Cellopt, the old licensing system will still be supported.
Actix Cellopt AFP Release Notes for Version 3.14.15
9
2 Resolved issues
2.1 Issues resolved in 3.14.15
2.1.1 Maximum separat ion doesn ‟ t work for sp l i t sectors
The model preparation relies on so called "confirmed plan entries". These are
frequency associations to radios that will be checked and validated before
optimization takes place, i.e. invalid frequencies, which e.g. violate some maximum
separation constraint or something else, will not be saved as confirmed plan entry
but rather be removed.
These removed plan entries won't be considered any longer for subsequent
narrowing down of the available frequencies due to the maximum separation
constraint. Hence, the plan entry of fixed radios should remain instead of being
removed due to constraint violation in order to be properly considered.
2 .1.2 Opt imizat ion wi th user -def ined MALs returns
ArrayIndexOutOfBoundsExcept ion
Certain configurations may have led to incorrectly initialized optimizer data
structures, when user-defined MALs are used, which caused an array access out of
bounds. This issue has been fixed.
2 .1.3 Synth Hopping Separat ion set t ings cause prob lems
There was a bug in the internal model preparation step performed in advance of an
optimization attempt that caused different kinds of groups to be mixed up by using
maximum separation group IDs and treating them as radio group IDs.
2 .1.4 Opt imizer incorrect l y reports “No ava i lable spect rum”
A bug during optimizer initialization caused an incorrect response concerning the
check for available spectrum under certain conditions when spare planning was not
used. This issue has been fixed.
2 .1.5 Incorrect pars ing of i nter ference threshold
The threshold value of the filter “Disable interference relations with
co-values less than or equal to” was not parsed correctly, which may have led to
unexpected modification of the value when repeatedly switching to the “Options for
Frequencies” dialog. This bug was fixed.
2.2 Issues resolved in 3.14.14
2.2.1 Inter ference matr i x ( IM) generat ion f rom DT fa i l ed
In version 3.14.13 a bug was introduced that caused the generation of interference
relations from drive test data to fail.
Actix Cellopt AFP Release Notes for Version 3.14.15
10
2.2.2 Ass ignment of l ayer “unass igned” in Category HSN leads to
zero being set as va lue
Instead of setting the value to zero (which would mean that the hopping sequence
is cyclic) no value is set, when the layer “unassigned” is selected, now.
2 .2.3 Export o f Rad io Edi tor fa i l ed due to unhandled number
format
In case of floating point values greater than or equal to 1,000.0 the export failed
due to the thousands separator which was not taken into account when trying to
convert the number.
2 .2.4 Wrong pos i t i on of radios when import ing Planet 5 projects
Although the frequency and the control radio attribute have been imported,
properly, the order of the radios (in their parent sector) did not match their order in
the Planet 5 project data. The order defined in the Planet project is preserved, now.
2.3 Issues resolved in 3.14.13
2.3.1 Nul l pointer except ion in Retune repor t
For grouped sectors the retune report didn't work if a retune potential was found.
2.4 Issues resolved in 3.14.12
2.4.1 L i cense act i vat i on wi th stand -alone act i vat i on wizard
When starting the license activation wizard via the start menu the license activation
failed because of incorrect paths used in the activation wizard. Those paths were
corrected.
2 .4.2 PDF generat ion of deta i l ed project overv iew
An intermediate file was created in the application's installation path, a location
which may not be writeable for all users (especially on Windows 7 systems).
The intermediate file is now created in the user's default directory for temporary
files so that the detailed project overview report can be generated again.
2.5 Issues resolved in 3.14.11
2.5.1 Creat ion of d i f ferent IM l i s ts f rom the same ASA export
h i s tograms
Different interference lists could be generated each time when the AFP
measurement file containing the histograms contained sectors that were not
present in the AFP model file.
Actix Cellopt AFP Release Notes for Version 3.14.15
11
Invalid histograms (referring to unknown sectors) are dropped while processing. A
bug prevented the removal of those invalid histograms and caused the observed
unpredictable results due to a race condition, and this has now been fixed.
Please note that non-unique sector names at a particular site are likely to cause
problems because Cellopt AFP tries to find corresponding sectors using a
combination of site/sector name, and the IDs used in the model and the
measurement file generally differ from each other.
2.6 Issues resolved in 3.14.10
2.6.1 GRFU Opt imizat ion returns
ArrayIndexOutOfBoundsExcept ion: -2 (SF61411)
Under certain circumstances, depending on the radios selected for optimization and
those radios being part of a maximum separation group, the input data structures
for the optimizer were incorrectly initialized. This caused an array access out of
bounds. The initialization of these data structures has been fixed.
2 .6.2 Opt imizer found l ess p lans when Maximum Separat ion
Groups were involved
In versions 3.14.8 and 3.14.9, when optimizing frequencies and maximum
separation groups have been used, the optimizer found fewer plans than it used to
until version 3.14.7. This was caused by an unintentional limitation of the
optimizer's capabilities, and is now fixed.
2.7 Issues resolved in 3.14.9
None.
2.8 Issues resolved in 3.14.8
2.8.1 Prob lem wi th saving f requency p lan to the database a f ter
the opt imizat ion (SF57918)
When saving frequency plans, AFP was sometimes failing to add MALs to the
database. This is now fixed.
2 .8.2 Opt imizer progress window shows huge green pena l t i es
(SF57918)
AFP was incorrectly reporting plans, as better plans, which resulted in huge
interference penalty scores in order to reduce important penalty scores. Though the
total score was less than the previous result, it wasn‟t a better plan because of the
huge rise in the interference score. The AFP code has been modified to discard such
plans.
Actix Cellopt AFP Release Notes for Version 3.14.15
12
2.9 Issues resolved in 3.14.7
2.9.1 Cel l opt unstable (SF57280)
This problem was caused by rapid progress bar messages sent by the server to the
client. Showing the progress bar is now configurable through the settings.xml file.
Client side logging level can also be configured in the settings.xml file.
2 .9.2 Di f f i cu l ty enabl ing d i sabled radios (SF56963)
If all radios are disabled in an AFP project, then in the Network page the "Enable
all" button was missing. Now the "Show Disabled", "Add Site" and "Enable All"
buttons show when the network contains disabled radios even when none of the
radios are enabled.
2 .9.3 Intermod pr ior i t i es sort ing incorrect l y on Pr ior i t i es page
(SF56997)
For the TETRA and LMR technology, the intermod rules are now sorted correctly on
the Priorities page. The sort order is 3rd, 5th, 7th, 9th, and then 11th order. Also,
on the right side of the page, in the "Add new Priorities" section, the order of the
intermod rules is now 3rd, 5th, 7th, 9th, and then 11th order.
2 .9.4 Right c l i ck pop-up menu doesn ' t work for some s i tes and
sectors in network t ree (SF55151)
Apostrophes in site-sector names caused the Network page right click functionality
to fail. It has now been fixed.
2 .9.5 Load ing t ime of AFP Templates too l ong (SF55256)
The problem, now fixed, was that MALs were being saved as part of the project
template.
2 .9.6 Export/ Import of p roject removes d i s tance l i s t penal t i es
(SF57381)
For the TETRA technology, this release fixes a problem which was due to the wrong
list type being set when exporting/importing a distance list. Now new lists have the
type set correctly.
2 .9.7 Radio Ed i tor Export of sectors fa i l s for TETRA technology
(SF58059)
Added support for tab delimited Import/export for TETRA technology.
2 .9.8 Fixed import of HSN (SF58656)
When importing data or creating a project using Cellopt 3 format, AFP was treating
the HSN value „0‟ as a null value. This is now fixed.
Actix Cellopt AFP Release Notes for Version 3.14.15
13
2.9.9 Fixed l ocale prob lem
When adding a new site in Dutch OS, AFP was not interpreting lat-long values
correctly. This is now fixed.
2.10 Issues resolved in 3.14.6
2.10.1 FAS data import (SF54824)
AFP was failing to import FAS data in UTF-16 format. The software has now been
modified to automatically detect and import data in UTF-8 or UTF-16 format.
Ericsson FAS data import has been modified to import floating point values. Note
that these are rounded to integers after import.
2.11 Issues resolved in 3.14.5
2.11.1 Tab del imi ted import (SF53854)
AFP failed to import Tab delimited data correctly when it contained Chinese
characters. This is now fixed.
2 .11.2 Project template export
It was failing to export template when project didn‟t contain bandmap frequencies.
It is now fixed.
2.12 Issues resolved in 3.14.4
2.12.1 Creat ing new project f rom template (SF52873)
It was not possible to create new project using a template containing empty lists.
This has now been fixed.
2.13 Issues resolved in 3.14.2
2.13.1 Except ion caused by event Export Template (SF50658)
When a project template was exported from a project which contained no
technology and had all lists deleted, AFP threw an exception. This has now been
fixed.
Actix Cellopt AFP Release Notes for Version 3.14.15
14
2.14 Issues resolved in 3.14.1
2.14.1 Rules d i sappear on restart ing of AFP (SF52104)
Adj rules were not getting saved when new category was created before saving the
rules. Hence these rules were disappearing when AFP restarted. This problem has
now been fixed.
2 .14.2 Corrected Adj -120 and Adj -240 ru les (SF52103)
Adj rules have been changed to Adj-120 and Adj-240 to Adj-119 and Adj-239. This
would allow user to achieve separation of 1.25 MHz and 3.0 MHz as required for
LMR technology.
2.15 When Issues resolved in 3.12.10
2.15.1 Improved Tab del imi ted import (SF50666)
When a tab-delimited file is imported to update a project, it does not update all the
radios when the number of radios in the file is lower than the number of radios in
the project for the given sector. A warning has been added to warn the user when
such cases are detected.
2 .15.2 Baseband radio import f rom Asset (SF50781)
Baseband radios when imported from Asset were incorrectly being applied MAL.
This was fixed in AFP3.11.2 RC and wasn‟t merged to AFP3.12. It has now been
merged to fix the issue.
2 .15.3 Large h i stogram import prob lem (SF50997)
When large histograms were imported and packet size was larger than 1MB, mysql
was throwing max_packet_allowed exception as default value is 1MB. It has now
been fixed by breaking down histogram size before storing into database.
2.16 Issues resolved in 3.12.9
2.16.1 Improved Er i csson FAS data import (SF50367)
Cellopt AFP was failing to import Ericsson FAS data from Maxis switches due to
changes in the file header. This has now been fixed.
2.17 Issues resolved in 3.12.8
2.17.1 Modi f i ed Cel l opt2 format data import (SF49760)
In previous releases, Cellopt2 format data had to contain all fields for import to be
successful. Now, iSITE, iSECT and iCONC messages can be imported without
Lat/Long, traffic and sep_type value respectively. These changes will be rolled back
once the equivalent issue is resolved in the Radioplan platform.
Actix Cellopt AFP Release Notes for Version 3.14.15
15
2.17.2 Opt imizat ion error (SF50181)
AFP was failing to optimize when the project contained One Set and Adhoc, and
MCRB radios. It has now been fixed.
2.18 Issues resolved in 3.12.7
2.18.1 Warn ing for dupl i cate s i tes during Cel l opt3 project import
Projects created by importing a Cellopt3 format project file containing duplicate site
definitions caused the histogram import to fail. This has now been fixed by
preventing the import of duplicated site definitions. If duplicate site definitions are
found, only the first definition is processed and a warning is produced for all other
site definitions having the same name.
2.19 Issues resolved in 3.12.6
2.19.1 Opt ion to include user -def ined layer (SF47606)
To prevent confusion, this option has been disabled for file-based summary reports.
2 .19.2 Browse but ton for send to f i l e opt ion
It was possible to click on the Analyze > Send to File > Browse button even when it
was grayed out. This has now been fixed for all relevant locations in the user
interface.
2.20 Issues resolved in 3.12.5
2.20.1 Vers ion number in emai l (SF48535)
An incomplete version number was being used in the email automatically generated
by Cellopt. This has been changed to include the patch number to correctly identify
the product from which the error report email is being sent.
2.21 Issues resolved in 3.12.4
2.21.1 MCRB feature
The MCRBs separation rule could not be applied in AFP3.12.2 and AFP3.12.3. This
feature was broken due to GRFU development work and has now been fixed.
2 .21.2 Changing avai lable f requency
When changing available frequencies on the Spectrum page, new frequency ranges
could not applied. This has now been fixed.
Actix Cellopt AFP Release Notes for Version 3.14.15
16
2.22 Issues resolved in 3.12.3
2.22.1 Removed d i sabled rad ios f rom warn ing
Disabled quads with either one or more than four radios were generating project
level warnings. These warnings have now been suppressed. This would help in
identifying enabled radios with a broken quad/widen rule. These warnings would
also be suppressed when running optimizer/analyzer.
2 .22.2 Al ias maps import prob lem using Cel lopt 3 format
When importing data using Cellopt 3 format Alias maps were not being created.
This is now fixed.
2 .22.3 Co and Adj import prob lem using tab del imi ted format
When using sector-based tab delimited format to import relations, Cellopt AFP did
not import Co and Adj values specified with relations. This is now fixed.
2 .22.4 Opt imizat ion problem when rad io i s member o f mul t ip l e
max- separat ion groups
The optimizer was sometimes failing to find a solution when the project contained
hopping separation groups that required a radio to be member of multiple max-
separation groups. The software is now changed to produce optimization results.
This problem was related to a newly developed GRFU feature.
2.23 Issues resolved in 3.12.2
2.23.1 L i censing prob lem when using the Loca l Act i vat i on server
We have integrated the fix for Local Activation that required the product to be
reactivated after it had been offline. This has now been fixed to allow offline use of
the product when using the Local Activation server.
2 .23.2 Progress bar update
Sometimes there was a delay between the progress bar showing completion and
the actual opening of a Microsoft Excel file. It has now been fixed so the progress
bar now correctly displays progress when exporting radio editor data to Excel.
2.24 Issues resolved in 3.12.1
2.24.1 iDEN set p lanning co-sector i ssue
When using set planning in iDEN, a few sectors with co-sector violations were not
being recognized by the optimizer, and were therefore not being resolved. The
violations could easily be detected in the frequency analysis report. This is now
fixed.
Actix Cellopt AFP Release Notes for Version 3.14.15
17
2.24.2 iDEN set p lanning unassigned sector i s sue
Another issue fixed with set planning was that some sets were not recognized
correctly, and as a result, some radios become unassigned.
2 .24.3 Server shutdown prob lem af ter h i s togram import
The server was not shutting down properly while exiting Cellopt AFP after
histograms created by ASA were imported. This is now fixed.
2 .24.4 Prob lem act i vat ing l i cense when Analyzer a l so insta l l ed
There was a problem reactivating a license using Activation wizard if Actix Analyzer
was also installed with legacy licensing (i.e. not Activation). This is now fixed.
2.25 Issues resolved in 3.12
2.25.1 Quad-X warning
Using the iDEN technology, there is a project warning when a QUAD combiner
contains only one radio.
Previously this only turned off for the 1st QUAD configuration; all other 2nd to 7th
QUADs were still reporting the same warning.
With AFP 3.12, this no longer happens; turning off the QUAD warning applies for all
QUAD configurations.
2 .25.2 Add BR too fast , hangs
When adding radios too quickly in the network tree, sometimes the application
would hang. Measures have been taken to minimize this possibility in 3.12.
2 .25.3 Change iDEN set st rategy in network t ree
In earlier versions of Cellopt AFP, it was not possible to change the important “Set
Strategy” category from the Network tree. The option was simply not available.
Instead, everything had to be done from the Radio Editor.
2 .25.4 Import Cel lOpt3 project f rom ASA not ass igning old p lan
When importing a Cellopt3 project created from ASA, the project did not have the
old frequency plan assigned as before, only the current plan. It is now fixed.
2 .25.5 Asset import of baseband f requency and HSN
Baseband frequency, HSN and MAIO were not imported correctly when read from
an Asset xml project. This has been partly fixed, in that the frequency and HSN are
now imported correctly. However, some problems still remain when importing the
MAIO parameter in baseband.
Actix Cellopt AFP Release Notes for Version 3.14.15
18
3 Known Issues
3.1.1 Export ing a Project Template wi thout f i rs t c l os ing AFP
causes a c rash
After creating a Project Template, you must close Cellopt AFP before exporting the
template. This issue is scheduled to be fixed in the next release.
3 .1.2 Sector-based tab-del imi ted import / export of rad ios and
sets
The sector-based tab-delimited (import / export) feature is not designed to work
with set planning. It is not possible to specify that a radio is assigned a frequency
from a set.
3 .1.3 Project sca labi l i ty issue
It is a known issue that the amount of memory that Cellopt AFP can use is limited
by the 32-bit Java virtual machine.
Some configurations will increase the available memory for Cellopt. This is done
with the “xmx” flag inside the <installation directory>\conf\settings.xml file.
The default value is set to 800Mb as seen in the picture (indicated by “Xmx800M”).
The value can be increased to around 1400Mb, depending on the local computer
configuration. Much higher values than this are currently not allowed by 32-bit
Java.
Actix Cellopt AFP Release Notes for Version 3.14.15
19
With this configuration change, the maximum number of radios can be around
25000, and even up to 50000.
3.1.4 Large reports i ssue
There is an issue with large reports in the frequency analysis when displaying this
on screen. When a very large report is displayed with thousands of lines, it might
cause the client and server to disconnect and hang the application.
3 .1.5 Unicode Fonts
Exporting reports to PDF format renders all non-Western characters as hashes.
There is an issue with applying fonts correctly in this format.
3 .1.6 The User Databases (Projects) are not removed when
uninsta l l ing Cel l opt AFP
The Cellopt AFP uninstaller does not remove the databases (projects) from the
directory. To free up hard drive space, these can be removed manually. The
location for the database is now in the All Users\Application Data:
C:\Documents and Settings\All Users\Application Data\Actix\Cellopt AFP\3.X or
3.12
3.1.7 Uninstal l may take l onger on some sys tems
3.1.8 Copy Project f rom AFP Contro l Panel does not work
Using Copy Project from Control Panel > Project Management > Copy project
produces a crash with an error message similar to this:
Model with id 15 does not exist
The workaround for this issue is to export the project to file and copy the AFP3 XML
file using Windows Explorer.
3 .1.9 Creat ing a project us ing a template does not work in a l l
instances
When creating a new project from a project template that includes Interference
Lists, and then importing an afp3 XML project that does not include an Interference
List, the project creation fails.
The workaround for this issue is to close the newly created blank project before
importing the afp3 project. This forces the DB to update, then you can open the
blank project and import the afp3 project file without errors.
3 .1.10 React i vat i on of l i censes a f ter upgrad ing to AFP 3.14.9
If a local license activation server is used, the information for the activation server
has to be entered again after upgrading to version 3.14.9.
Actix Cellopt AFP Release Notes for Version 3.14.15
20
After launching Cellopt AFP, this dialog will be displayed:
Confirming with Yes leads to this dialog:
Clicking Next now would cause a communication error due to missing information
about the license activation server – this information was erased during the
upgrade.
Instead, click Back.
Actix Cellopt AFP Release Notes for Version 3.14.15
21
In the next dialog, click the Advanced button:
This opens the dialog where license activation server information can be entered:
From here on, proceed as described in the User Guide.
Actix Cellopt AFP Release Notes for Version 3.14.15
22
4 Release History
Date Version New Features
Resolved Issues
User Guide Update
Apr-2010 AFP3.14.0 √ X √
May-2010 AFP3.14.1 X √ X
June-2010 AFP3.14.2 √ √ √
July-2010 AFP3.14.3 √ X √
Aug-2010 AFP3.14.4 √ √ X
Sep-2010 AFP3.14.5 X √ X
Nov-2010 AFP3.14.6 √ √ √
May-2011 AFP3.14.7 X √ √
June-2011 AFP3.14.8 X √ X
Aug-2011 AFP3.14.9 √ X √
Oct-2011 AFP3.14.10 √ √ √
Jan-2012 AFP3.14.11 √ √ X
Mar-2012 AFP3.14.12 √ X √
Jul-2012 AFP3.14.13 √ √ √
Oct-2012 AFP3.14.14 X √ X
Jan-2012 AFP3.14.15 X √ X
Actix Cellopt AFP Release Notes for Version 3.14.15
23
Import of 3.8 plans