adalet catalog draft increased safety vh4x vc4x meter housings adalet.com ©adalet adalet enclosure...
TRANSCRIPT
EXPLOSIONPROOF METER HOUSINGS
SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet
SCREW COVER
EXPL
OSI
ON
PRO
OF
MET
ER H
OU
SIN
GS
229
Explosionproof Meter Housings
ContentsExplosionproof Meter Housings Screw Cover 230
Window Screw Cover 238
Dome Cover 247
Drilling & Tapping Guidelines 255
EXPLOSIONPROOF METER HOUSINGS
ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet
SCREW COVER
EXPLOSIO
NPR
OO
FM
ETER H
OU
SING
S
230
Screw Cover Explosionproof Meter Housings
XJDH N44 1/8” x 4 1/8” x 3”
Cover Opening 3 3/4”
XJDAH N45 3/4” x 5 3/4” x 4 7/8”
Cover Opening 4 3/16”
XJSH N4(Tapped on side pads only)
4” I.D. x 2 22/32” depthCover Opening 4”
XJLH N46” x 6” x 3 9/16”
Cover Opening 5 3/8”
XJTH N45 13/16” x 6 9/16” x 4”
Cover Opening 5 3/8”
XJHAH N47 3/16” x 9 3/16” x 4”Cover Opening 7”
XJMCH N46 3/4” x 6 3/4” x 3”
Cover Opening 7”
XJMAH N46 3/4” x 6 3/4” x 5”
Cover Opening 7”
XJMH N46 3/4” x 6 3/4” x 8”
Cover Opening 7”
XJXH N44 7/8” x 4 7/8” x 3 1/16”Cover Opening 4 3/4”
XJKAH N49 1/2” x 11 1/2” x 8 1/8”Cover Opening 9”
XJKH N49 1/2” x 11 1/2” x 6 1/8”Cover Opening 9”
XJHCH N47 3/4” x 10 5/16” x 5”Cover Opening 7”
XJHBH N47 1/4” x 9 1/8” x 6”
Cover Opening 7”
XJNH 6 & 12 N411 1/2” x 12 3/4” x 6(12)”Cover Opening 10 3/4”
• Drilled and tapped to specification, attach layout sheet. • Dimensions are nominal internal.
A
E
C
BD
H
G
K
JF
A
E
C
BD
H
G
K
JF
XJWHH N46 7/8” I.D. x 4 7/8” D
Cover Opening 6 7/8”
XJWTH N45 3/8” I.D. x 3 3/4” D
Cover Opening 5 3/8”
UL 1203CSA C22.2 No. 25 & 30 UL 50
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4
CERTIFICATIONS
EXPLOSIONPROOF METER HOUSINGS
SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet
sCrEW CoVEr
EXPL
OSI
ON
PRO
OF
MET
ER H
OU
SIN
GS
231
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GClass IIIClass I, Zone 1, AEx d IIB+H2Ex d IIB+H20539 II 2GD (Optional)*EEx d IIB+H2 (Optional)*IP 66NEMA Type 4
*specify ATEX if required
UL 1203CSA C22.2 No. 25 & 30 UL 60079-0/UL 60079-1CSA 60079-0/CSA 60079-1ATEX Directive 94/9/ECEN 50014, EN50018IEC 60529
UL 50
CERTIFICATIONS
Screw Cover Explosionproof / flameproof Meter Housings
A
E
C
BD
H
G
K
JF
A
E
C
BD
H
G
K
JF
XJDHX N44 1/8” x 4 1/8” x 3”
Cover Opening 3 3/4 ”
XJDAHX N45 3/4 ” x 5 3/4 ” x 4 7/8”
Cover Opening 4 3/16”
XJSHX N4(Tapped on side pads only)
4” I.D. x 2 22/32” depthCover Opening 4”
XJLHX N46” x 6” x 3 9/16”
Cover Opening 5 3/8”
XJTHX N45 13/16” x 6 9/16” x 4”
Cover Opening 5 3/8”
XJHAHX N47 3/16” x 9 3/16” x 4”Cover Opening 7”
XJMCHX N46 3/4 ” x 6 3/4 ” x 3”
Cover Opening 7”
XJMAHX N46 3/4 ” x 6 3/4 ” x 5”
Cover Opening 7”
XJMHX N46 3/4 ” x 6 3/4 ” x 8”
Cover Opening 7”
XJXHX N44 7/8” x 4 7/8” x 3 1/16”
Cover Opening 4 3/4”
XJKAHX N49 1/2 ” x 11 1/2 ” x 8 1/8”Cover Opening 9”
XJKHX N49 1/2 ” x 11 1/2 ” x 6 1/8”Cover Opening 9”
XJHCHX N47 3/4 ” x 10 5/16” x 5”Cover Opening 7”
XJHBHX N47 1/4 ” x 9 1/8” x 6”
Cover Opening 7”
XJNHX 6 & 12 N411 1/2 ” x 12 3/4 ” x 6(12)”Cover Opening 10 3/4 ”
XJWHHX N46 7/8” I.D. x 4 7/8” D
Cover Opening 6 7/8”
XJWTHX N45 3/8” I.D. x 3 3/4 ” D
Cover Opening 5 3/8”
• Drilled and tapped to specifi cation, attach layout sheet. • Dimensions are internal.
EXPLOSIONPROOF METER HOUSINGS
ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet
sCrEW CoVEr
EXPLOSIO
NPR
OO
FM
ETER H
OU
SING
S
232
XJDH N4XJDHX N4
XJDAH N4XJDAHX N4
XJSH N4XJSHX N4
*XJS can be tapped on side pads only.
• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)
5 1⁄83 ¾
34 5⁄8
3 11⁄166 3⁄165 1⁄84 1⁄8
6 ¾5 ¼
4 7⁄86 5⁄8
4 3⁄168 3⁄86 ¾5 ¾
3 ¾4 7⁄16
4 5⁄322 23⁄32
4
4 7⁄163 ¾
¾
5 1⁄83 ¾
34 5⁄8
3 11⁄166 3⁄165 1⁄84 1⁄8
6 ¾5 ¼
4 7⁄86 5⁄8
4 3⁄168 3⁄86 ¾5 ¾
3 ¾4 7⁄16
4 5⁄322 23⁄32
4
4 7⁄163 ¾
¾
Screw Cover Explosionproof Meter Housings
STANDARD FEATURES
CAT. NUMBER CONDUIT SIZE
INSIDE DIM.W L D
DIAMETER COVER
OPENING
MOUNTING HOLE SIZE
WEIGHT(LBS)
XJDH N4
XJDAH N4
XJSH N4*
2
1
1
4 1/8
5 3/4
4
4 1/8
3 3/4
-
3
4 7/8
2 23/32
3 3/4
4 3/16
4
7/16
7/16
5/16
5 1/2
11 1/2
2 3/4
NOMINAL DIMENSIONS
UL 1203CSA C22.2 No. 25 & 30 UL 50
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4
CERTIFICATIONS
EXPLOSIONPROOF METER HOUSINGS
SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet
sCrEW CoVEr
EXPL
OSI
ON
PRO
OF
MET
ER H
OU
SIN
GS
233
• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)XJLH N4
XJLHX N4
XJTH N4XJTHX N4
XJXH N4XJXHX N4
8 3⁄8
5 ¼
7
6
6 7
5 7⁄83 9⁄16
5 3⁄8
6 9⁄166
4
7 7⁄16
5 13⁄16
6 11⁄16
7 ¾
6 7⁄16
5 ¾
4 7⁄8
5 ¾
6 ¾
4 ¾
4 ¾
5 ¾
5 1⁄163 1⁄16
CAT. NUMBER CONDUIT SIZE
INSIDE DIM.W L D
DIAMETER COVER
OPENING
MOUNTING HOLE SIZE
WEIGHT(LBS)
XJLH N4
XJTH N4
XJXH N4
2
2
2
6
5 13/16
4 7/8
6
6 9/16
4 7/8
3 9/16
4
3 1/16
5 3/8
5 3/8
4 3/4
7/16
1/2
11/2 3
9 1/2
11
6 1/4
NOMINAL DIMENSIONS
STANDARD FEATURES
Screw Cover Explosionproof / flameproof Meter Housings
UL 1203CSA C22.2 No. 25 & 30 UL 50
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4
CERTIFICATIONS
EXPLOSIONPROOF METER HOUSINGS
ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet
sCrEW CoVEr
EXPLOSIO
NPR
OO
FM
ETER H
OU
SING
S
234
• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)
Screw Cover Explosionproof Meter Housings
STANDARD FEATURES
XJMH N4XJMHX N4
XJMAH N4XJMAHX N4
XJMCH N4XJMCHX N4
9 1⁄8
4
6 ¼
7 ¾
11 ¾
6 ¾
7 ¾6 ¾
7
9 1⁄8
5
6 ¼
7 ¾
8 ¾
6 ¾
7 ¾6 ¾
7
9 1⁄8
3
6 ¼
7 ¾
6 ¾
6 ¾
7 ¾
6 ¾
7
CAT. NUMBER CONDUIT SIZE
INSIDE DIM.W L D
DIAMETER COVER
OPENING
MOUNTING HOLE SIZE
WEIGHT(LBS)
XJMH N4
XJMAH N4
XJMCH N4*
2
2
2
6 3/4
6 3/4
6 3/4
6 3/4
6 3/4
6 3/4
8
5
3
7
7
7
7/16
7/16
5/16
21 1/2
16 1/2
14 1/2
NOMINAL DIMENSIONS
UL 1203CSA C22.2 No. 25 & 30 UL 50
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4
CERTIFICATIONS
EXPLOSIONPROOF METER HOUSINGS
SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet
sCrEW CoVEr
EXPL
OSI
ON
PRO
OF
MET
ER H
OU
SIN
GS
235
XJHAH N4 XJHAHX
XJHBH N4XJHBHX N4
XJHCH N4 XJHCHX N4
4
9 ¾
10 3⁄16
6 9⁄16
9 3⁄16
8 3⁄16
7 3⁄16
7
8 ¾
6
9 ¾
10 ¼
8 11⁄16
9 1⁄16
8 3⁄8
7 ¼
7
8 7⁄8
10 ¼
11 7⁄16
7 9⁄16
10 5⁄16
8 7⁄8
7 ¾
7
7 ¾
5 11⁄16
• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated. • The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)
CAT. NUMBER CONDUIT SIZE
INSIDE DIM.W L D
DIAMETER COVER
OPENING
MOUNTING HOLE SIZE
WEIGHT(LBS)
XJHAH N4
XJHBH N4
XJHCH N4
2
2
2
7 3/16
7 1/4
7 3/4
9 3/16
9 1/8
10 5/16
4
6
5
7
7
7
9/16
9/16
9/16
16 1/2
22
18
NOMINAL DIMENSIONS
STANDARD FEATURES
Screw Cover Explosionproof / flameproof Meter Housings
UL 1203CSA C22.2 No. 25 & 30 UL 50
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4
CERTIFICATIONS
EXPLOSIONPROOF METER HOUSINGS
ADALET.COM AdAleT enclosure sysTems | 4801 WesT 150Th | cleVelAnd, ohIo 44135©Adalet
sCrEW CoVEr
EXPLOSIO
NPR
OO
FM
ETER H
OU
SING
S
236
• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated.• The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)
Screw Cover Explosionproof Meter Housings
STANDARD FEATURES
CAT. NUMBER CONDUIT SIZE
INSIDE DIM.W L D
DIAMETER COVER
OPENING
MOUNTING HOLE SIZE
WEIGHT(LBS)
XJKH N4
XJKAH N4
3
3
9 1/2
9 1/2
11 1/2
11 1/2
6 1/8
8 1/8
9
9
9/16
9/16
40
44
NOMINAL DIMENSIONS XJKH N4XJKHX N4
XJKAH N4XJKAHX N4
12 3⁄8
11 ½
6 1⁄8
9 ½
9 1⁄8
10 ¾
8
12 ¾
9 1⁄8
12 3⁄8
11 ½
8 1⁄8
9 ½
9 1⁄8
10 ¾
8
12 ¾
11 1⁄8
UL 1203CSA C22.2 No. 25 & 30 UL 50
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4
CERTIFICATIONS
EXPLOSIONPROOF METER HOUSINGS
SEND ORDERS TO [email protected] T: 216.267.9000 | F:216.267.1681 | [email protected] ©Adalet
sCrEW CoVEr
EXPL
OSI
ON
PRO
OF
MET
ER H
OU
SIN
GS
237
A
E
C
BD
H
G
K
JF
A
E
C
BD
H
G
K
JF
XJWHH N4XJWHHX N4
A
E
C
BD
H
G
K
JF
XJWTH N4XJWTHX N4
A
E
C
BD
H
G
K
JF
• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum conduit size as indicated.• A large cover opening enhances mounting pan installation.• Two depths available for a wider selection of effi cient component packaging• The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)
14 3⁄8
11 ½
16 ¾
10 ¾
12 ¾9
13 1⁄8
XJNH N4XJNHX N4
Screw Cover Explosionproof Meter Housings
STANDARD FEATURES
• The heavy wall sections of these boxes are thick enough to provide the required fi ve threads for the maximum size as indicated.• The boxes are drilled and tapped to specifi cation. (A layout sketch should be attached to each order.)
NOMINAL DIMENSIONS (Inches)
CAT. NUMBER A B C D E F G H J K
XJWHH N4 7-3/4 7 3/4 6 3/8 6 3/8 7/16 5 5/8 4 9/16 1 13/16 1 3/4 7 7/8
XJWTH N4 6 1/4 6 1/4 5 1/8 5 1/8 3/8 5 1/8 4 1 1/2 1 7/16 6 3/8
STANDARD FEATURES
CAT. NUMBER CONDUIT SIZE
INSIDE DIM.W L D
DIAMETER COVER
OPENING
MOUNTING HOLE SIZE
WEIGHT(LBS)
XJNH 6
XJNH 12
4
4
11 1/2
11 1/2
12 3/4
12 3/4
6
12
10 3/4
10 3/4
5/8
5/8
61
85
NOMINAL DIMENSIONS
CAT. NUMBER CONDUIT SIZE
INSIDE DIM.Dia. D
DIAMETER COVER
OPENING
MOUNTING HOLE SIZE
WEIGHT(LBS)
XJWHH N4
XJWTH N4
2 1/2
2
6 7/8
5 3/8
4 7/8
3 3/4
6 7/8
5 3/8
7/16
3/8
8 1/2
7 1/2
NOMINAL DIMENSIONS
OVERALLHEIGHT
9 13/16
13 5/16
UL 1203CSA C22.2 No. 25 & 30 UL 50
Class I, Div. 1, Groups B, C, DClass II, Groups E, F, GNEMA Type 4
CERTIFICATIONS