Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal cell. Note When Current HO Control Algorithm in SET GCELLHOBASIC is set to HOALGORITHM1(Handover algorithm I), Inter-cell HO Hysteresis should be set within the range of 64-127. When Current HO Control Algorithm in SET GCELLHOBASIC is set to HOALGORITHM2(Handover algorithm II), Inter-cell HO Hysteresis should be set within the range of 0-127. Parameters Parameter ID Paramet er Name Parameter Description IDTYPE Index Type Meaning: Index type GUI Value Range: BYNAME(By name), BYID(By index), BYCGI(By CGI) Unit: None Actual Value Range: BYNAME, BYID, BYCGI MML Default Value: None Recommended Value: None

Upload: truongnhan

Post on 08-Feb-2018

315 views

Category:

Documents


16 download

TRANSCRIPT

Page 1: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Add 2G Neighbor Cell(ADD G2GNCELL)Function

Use this command to add a 2G neighboring internal cell.

Note

When Current HO Control Algorithm in SET GCELLHOBASIC is set to HOALGORITHM1(Handover algorithm I), Inter-cell HO Hysteresis should be set within the range of 64-127. When Current HO Control Algorithm in SET GCELLHOBASIC is set to HOALGORITHM2(Handover algorithm II), Inter-cell HO Hysteresis should be set within the range of 0-127.

Parameters

Parameter ID Parameter Name

Parameter Description

IDTYPE Index Type

Meaning: Index type

GUI Value Range: BYNAME(By name), BYID(By index), BYCGI(By CGI)

Unit: None

Actual Value Range: BYNAME, BYID, BYCGI

MML Default Value: None

Recommended Value: None

Page 2: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

SRC2GNCELLID Source Cell Index

Meaning: A cell Index must be unique in one BSC

. It is used to uniquely identify a cell.

GUI Value Range: 0~2047

Unit: None

Actual Value Range: 0~2047

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And

Page 3: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

no impact on the UE in idle mode)

Impact on Network Performance: None

SRC2GNCELLNAME Source Cell Name

Meaning: Name of a cell.

Cell names cannot contain the following invalid characters:

, ; = " '

In addition, cell names cannot contain two or moreconsecutive %, two or more consecutive spaces, ormore than three consecutive +.

GUI Value Range: None

Unit: None

Actual Value Range: 1~64 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Page 4: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NBR2GNCELLID Neighbor2G Cell Index

Meaning: Uniform number of a cell index within aBSC

, which uniquely identifies a cell.

GUI Value Range: 0~12287

Unit: None

Actual Value Range: 0~12287

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

Page 5: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

NBR2GNCELLNAME Neighbor2G Cell Name

Meaning: Name of a cell.

Cell names cannot contain the following invalid characters:

, ; = " '

In addition, cell names cannot contain two or moreconsecutive %, two or more consecutive spaces, ormore than three consecutive +.

GUI Value Range: None

Unit: None

Actual Value Range: 1~64 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

Page 6: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

SRCMCC Source Cell MCC

Meaning: Mobile country code (MCC) of the source cell

GUI Value Range: None

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

SRCMNC Source Cell MNC

Meaning: Mobile network code (MNC) of the source cell

GUI Value Range: None

Page 7: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

SRCLAC Source Cell LAC

Meaning: Local area code (LAC) of the source cell

GUI Value Range: 1~65533, 65535

Unit: None

Actual Value Range: 1~65533, 65535

Page 8: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

SRCCI Source Cell CI

Meaning: Source cell ID

GUI Value Range: 0~65535

Unit: None

Actual Value Range: 0~65535

MML Default Value: None

Recommended Value: None

Page 9: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NBRMCC Neighbour Cell MCC

Meaning: Mobile Country Code (MCC) of a neighboring cell

GUI Value Range: None

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Page 10: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Impact on Network Performance: None

NBRMNC Neighbour Cell MNC

Meaning: Mobile Network Code (MNC) of a neighboring cell

GUI Value Range: None

Unit: None

Actual Value Range: 1~3 characters

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NBRLAC Neighbour Cell LAC

Meaning: Local Area Code (LAC) of a neighboring cell

Page 11: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

GUI Value Range: 1~65533, 65535

Unit: None

Actual Value Range: 1~65533, 65535

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NBRCI Neighbour Cell CI

Meaning: Cell ID of a neighboring cell

GUI Value Range: 0~65535

Unit: None

Page 12: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Actual Value Range: 0~65535

MML Default Value: None

Recommended Value: None

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NCELLTYPE Neighboring Cell Type

Meaning: The parameter indicates whether the neighboring cell is a handover neighboring cell, anIBCA neighboring cell, or a handover and IBCA neighboring cell of the serving cell. If the parameter is set to HANDOVERNCELL(Handover Neighboring Cell), the neighboring cell is the handover neighboring cell but not the IBCA neighboring cellof the serving cell. If the parameter is set to IBCANCELL(IBCA Neighboring Cell), the neighboring cell is the IBCA neighboring cell but not the handover neighboring cell of the serving cell. If the parameter is set to HANDOVERANDIBCANCELL(Handover and IBCA Neighboring Cell), the neighboring cell is the handover neighboring cell and IBCA neighboring cell of the serving cell. IBCA neighboring cells are some neighboring cells of a serving cell with its IBCA algorithm enabled. There is co-channel or adjacent-channel

Page 13: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

interference between the IBCA neighboring cells and the serving cell. Handover neighboring cells are candidate target cells of the serving cell during a handover.

GUI Value Range: HANDOVERNCELL(Handover Neighboring Cell), IBCANCELL(IBCA Neighboring Cell), HANDOVERANDIBCANCELL(Handover and IBCA Neighboring Cell)

Unit: None

Actual Value Range: HANDOVERNCELL, IBCANCELL, HANDOVERANDIBCANCELL

MML Default Value: HANDOVERNCELL(Handover Neighboring Cell)

Recommended Value: HANDOVERNCELL(Handover Neighboring Cell)

Parameter Relationship: This parameter can be set to IBCANCELL(IBCA Neighboring Cell) or HANDOVERANDIBCANCELL(Handover and IBCA Neighboring Cell) only if IBCAALLOWED is set to YES(Yes) for a cell.

Page 14: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

SRCHOCTRLSWITCH Current HO CTRL Algorithm in Source Cell

Meaning: Whether the currently used handover algorithm in the source cell is HO Algorithm I or HO Algorithm II

GUI Value Range: HOALGORITHM1(Handover algorithm I), HOALGORITHM2(Handover algorithm II)

Unit: None

Actual Value Range: HOALGORITHM1, HOALGORITHM2

MML Default Value: HOALGORITHM1(Handover algorithm I)

Recommended Value: HOALGORITHM1(Handover algorithm I)

Parameter Relationship: The value of this parameter must be the same as that of HOCTRLSWITCH in SET GCELLHOBASIC.

Page 15: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

INTERCELLHYST Inter-cell HO Hysteresis

Meaning: Hysteresis value during the handovers between cells, This value is used to suppress ping-pong handovers between cells. The actual value of this parameter is equal to the GUI value minus 64.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 68

Recommended Value: In densely populated urban areas, the recommended value is 68; in the suburbs, the recommended value is 72.

Parameter Relationship: When Current HO Control Algorithm in SET GCELLHOBASIC isset to HOALGORITHM1(Handover algorithm I), Inter-cell HO Hysteresis should be set within the range of 64-127.When Current HO Control Algorithm in SET GCELLHOBASIC is set to HOALGORITHM2(Handover algorithm II),

Page 16: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Inter-cell HO Hysteresis should be set within the range of 0-127.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

MINOFFSET Min Access Level Offset

Meaning: Minimum receive level offset. MSs can be handed over to a neighboring cell when both of the following conditions are met:

Downlink receive level of the neighboring cell is greater than or equal to the sum of HOCDCMINDWPWR and the value of this parameter.

Uplink receive level of the neighboring cell is greater than or equal to the sum of HOCDCMINUPPWR and the value of this parameter.

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 0

Page 17: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Recommended Value: 0

Parameter Relationship: This parameter is based on HOCDCMINDWPWR and HOCDCMINUPPWR. Different offset can be setfor different neighboring cells. The following condition must be met for a neighboring cell to be added into the candidate cell queue: Neighboring cell uplink level >= (HOCDCMINUPPWR + MINOFFSET); Neighboring cell downlink level >= (HOCDCMINDWPWR + MINOFFSET).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

PBGTMARGIN PBGT HO Threshold

Meaning: Threshold for triggering PBGT handovers. PBGT handovers to a neighboring cell can be triggered when the following condition is met:Path loss in the serving cell - Path loss in the neighboring cell > Actual value of this parameter.If this parameter is set to a value less than 64, calls can be handed over back to a neighboring cell whose path loss is greater than that in the serving cell. The actual value of this parameter is equal to the GUI value minus 64.

GUI Value Range: 0~127

Unit: dB

Page 18: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Actual Value Range: -64~63

MML Default Value: 68

Recommended Value: In densely populated urban areas, the recommended value is 68; in the suburbs, the recommended value is 72.

Parameter Relationship: This parameter is valid only if HOCTRLSWITCH in the SET GCELLHOBASIC command is set to HOALGORITHM1(Handover algorithm I) and PBGTHOEN in the SET GCELLHOBASIC command is set to YES(Yes).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

BQMARGIN BQ HO Margin

Meaning: Difference between the downlink receive level of the serving cell and that of a neighboring cell during bad quality handovers. This parameter is used to calculate the bad quality handover hysteresis based on the following formula:

Bad quality handover hysteresis = Value of INTERCELLHYST -Value of this parameter

Bad quality handovers to a neighboring cell can betriggered when the following condition is met:

Page 19: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

(Downlink receive level of the neighboring cell after filtering - Downlink receive level of the serving cell after power control compensation) > (Value of INTERCELLHYST - 64) - (Value of this parameter - 64). The actual value of this parameter is equal to the GUI value minus 64.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 69

Recommended Value: 69

Parameter Relationship: This parameter is used with INTERCELLHYST to calculate the bad quality handover hysteresis.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

ISCHAINNCELL Chain Meaning: Whether the cell is a chain neighboring

Page 20: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

NeighborCell

cell. The parameter is used in the quick handover algorithm. Quick handover aims to increase the handover success rate of an MS moving at a high speed and to ensure the call continuity and low calldrop rate. Quick handover applies to the scenario where an MS moves fast along an urban backbone road, a selected route, or a high-speed railroad. The target cell must be a chain neighboring cell.

GUI Value Range: NO(No), YES(Yes)

Unit: None

Actual Value Range: NO, YES

MML Default Value: NO(No)

Recommended Value: NO(No)

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

INTELEVHOHYST Adjacent Cell

Meaning: Hysteresis value during the handovers between cells on different layers or of different

Page 21: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Inter-layer HOHysteresis

priorities. This value is used to suppress inter-layerping-pong handovers. The actual value of this parameter is equal to the GUI value minus 64.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 67

Recommended Value: 67

Parameter Relationship: Inter-layer HO threshold of the serving cell = Inter-layer HO threshold - Inter-layer HO Hysteresis. Inter-layer HO threshold of the neighboring cell = Inter-layer HO threshold + Adjacent Cell Inter-layer HO Hysteresis - 64. The value of Inter-layer HO threshold can be set through SET GCELLHOBASIC.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

Page 22: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

DRHOLEVRANGE Directed Retry Handover Level Range

Meaning: Difference between the downlink receive level of the serving cell and that of a neighboring cell during handovers due to directed retry. In the case of Huawei handover algorithm II,this parameter is used to calculate the hysteresis ofhandovers due to directed retry based on the following formula:

Hysteresis of handovers due to directed retry = Value of INTERCELLHYST - Value of this parameter

Handovers due to directed retry to a neighboring cell can be triggered when the following condition is met:

(Downlink receive level of the neighboring cell after filtering - Downlink receive level of the serving cell after power control compensation) > (Value of INTERCELLHYST - 64) - (Value of this parameter - 64).If EDGEHOHYSTEN in the SET GCELLHOBASICcommand is set to YES, INTERCELLHYST is replaced by EDGEHOHYST.

GUI Value Range: 0~128

Unit: dB

Actual Value Range: 0~128

MML Default Value: 72

Page 23: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Recommended Value: 72

Parameter Relationship: 1. This parameter is valid only if HOCTRLSWITCH in the SET GCELLHOBASIC command is set to HOALGORITHM2 and DIRECTRYEN in the SET GCELLBASICPARA command is set to YES. 2. INTERCELLHYST and EDGEHOHYST together determine the direct retry handover hysteresis.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

CHAINNCELLTYPE Chain Neighbour Cell Type

Meaning: This parameter indicates the geographical relationship between the neighboringcell and the serving cell. In the BSC, if direction A is selected, then the reverse direction is B.

GUI Value Range: QUICK_HO_NCELL_TYPE_A(QUICK_HO_NCELL_TYPE_A), QUICK_HO_NCELL_TYPE_B(QUICK_HO_NCELL_TYPE_B)

Unit: None

Actual Value Range: QUICK_HO_NCELL_TYPE_A,

Page 24: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

QUICK_HO_NCELL_TYPE_B

MML Default Value: QUICK_HO_NCELL_TYPE_A(QUICK_HO_NCELL_TYPE_A)

Recommended Value: QUICK_HO_NCELL_TYPE_A(QUICK_HO_NCELL_TYPE_A)

Parameter Relationship: None

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: The setting of this parameter depends on the actual physical location of the chain neighboring cell. Otherwise, fast PBGT handover fails.

EDGEADJSTATTIME Edge HOAdjCell Watch Time

Meaning: According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighborcell for edge handover in P of N measurement reports, the edge handover to the neighbor cell is triggered.

This parameter specifies the number N.

GUI Value Range: 1~32

Page 25: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6

Recommended Value: 6

Parameter Relationship: This parameter is valid only if FRINGEHOEN in the SET GCELLHOBASIC command is set to YES(Yes).The parameter value must meet the following requirement:EDGEADJSTATTIME >= EDGEADJLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

EDGEADJLASTTIME Edge HOAdjCell Valid Time

Meaning: According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighborcell for edge handover in P of N measurement reports, the edge handover to the neighbor cell is triggered.

This parameter specifies the number P.

Page 26: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid only if FRINGEHOEN in the SET GCELLHOBASIC command is set to YES(Yes). The parameter value must meet the following requirement: EDGEADJSTATTIME >= EDGEADJLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: 1. If this parameter is set to a large value, an MS needs to wait a long time before performing a handover. As a result, voice quality deteriorates or the call drop rate increases. 2. If this parameter is set to a small value, an MS performs handovers frequently, leading to unnecessary handovers.

LEVSTAT Layer Meaning: The triggering of inter-layer handovers

Page 27: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

HO Watch Time

must meet the P/N criteria. An inter-layer handover is triggered when P of N measurement reports meet the condition for inter-layer handovers. This parameter corresponds to the N in the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6

Recommended Value: 6

Parameter Relationship: This parameter is valid only when HOCTRLSWITCH is set to HOALGORITHM1 and LEVHOEN is set to YES. The following condition must be met: LEVSTAT >= LEVLAST.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, unnecessary handovers are performed, deteriorating the speech quality and

Page 28: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

causing ping-pong handovers. If this parameter is set to a small value, congestion occurs in the macro cell.

LEVLAST Layer HO ValidTime

Meaning: The triggering of inter-layer handovers must meet the P/N criteria. An inter-layer handover is triggered when P of N measurement reports meet the condition for inter-layer handovers. This parameter corresponds to the P in the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid only when HOCTRLSWITCH is set to HOALGORITHM1 and LEVHOEN is set to YES. The following condition must be met: LEVSTAT >= LEVLAST.

Service Interrupted After Modification: No (And

Page 29: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, congestion occurs in macro cells. If this parameter is set to a small value, unnecessary handovers are performed, deteriorating the speech quality and causing ping-pong handovers.

PBGTSTAT PBGT Watch Time

Meaning: The triggering of PBGT handovers must meet the P/N criteria. A PBGT handover is triggered when P of N measurement reports meet the condition for PBGT handovers. This parametercorresponds to the N in the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6

Recommended Value: 6

Parameter Relationship: This parameter is valid only when HOCTRLSWITCH is set to HOALGORITHM1 and PBGTHOEN is set to YES. The following condition must be met:

Page 30: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

PBGTSTAT >= PBGTLAST.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, unnecessary handovers are likely to perform. If this parameter is set to a smallvalue, handovers are unlikely to perform in a timely manner, causing call drops.

PBGTLAST PBGT Valid Time

Meaning: The triggering of PBGT handovers must meet the P/N criteria. A PBGT handover is triggered when P of N measurement reports meet the condition for PBGT handovers. This parametercorresponds to the P in the P/N criteria.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Page 31: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Parameter Relationship: This parameter is valid only when HOCTRLSWITCH is set to HOALGORITHM1 and PBGTHOEN is set to YES. The following condition must be met: PBGTSTAT >= PBGTLAST.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, causing call drops. If this parameter is set to a small value, unnecessary handovers are performed.

BETTERCELLSTATTIME Better Cell HO Watch Time

Meaning: Period during which handovers to a better cell are measured. According to the P/N rule, handovers to a better cell can be triggered when the conditions for handovers to a better cell are met for P seconds within N seconds. This parameter specifies N in the P/N rule.

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 6

Page 32: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Recommended Value: 6

Parameter Relationship: This parameter is valid only when BETTERCELLHOEN is set to YES and HOCTRLSWITCH is set to HOALGORITHM2. The following condition mustbe met: BETTERCELLSTATTIME >= BETTERCELLLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, unnecessary handovers are triggered. If this parameter is set to a small value, handovers cannot be performed in a timely manner, affecting voice quality or causing call drops.

BETTERCELLLASTTIME Better Cell HO Valid Time

Meaning: Period during which the conditions for handovers to a better cell are met. According to theP/N rule, handovers to a better cell can be triggered when the conditions for handovers to a better cell are met for P seconds within N seconds. This parameter specifies P in the P/N rule.

GUI Value Range: 1~32

Unit: 0.5s

Page 33: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid only when BETTERCELLHOEN is set to YES and HOCTRLSWITCH is set to HOALGORITHM2. The following condition mustbe met: BETTERCELLSTATTIME >= BETTERCELLLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, affecting voice quality or causing call drops. If this parameter is set to a small value, unnecessary handovers are triggered.

HOSTATICTIME Quick Handover Static Time

Meaning: According to the P/N rule, if the conditions for fast handover are met in P of N measurement reports, the handover is triggered.

This parameter specifies the number N.

GUI Value Range: 1~32

Page 34: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid only when QUICKHOEN in SET GCELLHOBASIC is set to YES. The following condition must be met: HOSTATICTIME >= HOLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, causing call drops. If this parameter is set to a small value, unnecessary handovers are triggered.

HOLASTTIME Quick Handover Last Time

Meaning: According to the P/N rule, if the conditions for fast handover are met in P of N measurement reports, the handover is triggered.

This parameter specifies the number P.

Page 35: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

GUI Value Range: 1~32

Unit: 0.5s

Actual Value Range: 0.5~16

MML Default Value: 3

Recommended Value: 3

Parameter Relationship: This parameter is valid only when QUICKHOEN in SET GCELLHOBASIC is set to YES. The following condition must be met: HOSTATICTIME >= HOLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, causing call drops. If this parameter is set to a small value, unnecessary handovers are triggered.

HCSSTATTIME HCS HO Watch Time

Meaning: According to the P/N rule, if the conditions for the handover to a different micro cell due to fast movement are met in P of N

Page 36: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

measurement reports, the handover is triggered.

This parameter specifies the number N.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 3

Recommended Value: 3

Parameter Relationship: This parameter is valid only if HOCTRLSWITCH in the SET GCELLHOBASIC command is set to HOALGORITHM2(Handover algorithm II) and QCKMVHOEN in the SET GCELLHOBASIC command is set to YES(Yes).The parameter value must meet the following requirement:HCSSTATTIME >= HCSLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameter

Page 37: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

is set to a large value, congestion occurs in macro cells. If this parameter is set to a small value, handovers cannot be performed in a timely manner, causing call drops or more handovers.

HCSLASTTIME HCS HO Valid Time

Meaning: According to the P/N rule, if the conditions for the handover to a different micro cell due to fast movement are met in P of N measurement reports, the handover is triggered.

This parameter specifies the number P.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 2

Recommended Value: 2

Parameter Relationship: This parameter is valid only if HOCTRLSWITCH in the SET GCELLHOBASIC command is set to HOALGORITHM2(Handover algorithm II) and QCKMVHOEN in the SET GCELLHOBASIC command is set to YES(Yes).The parameter value must meet the following requirement:HCSSTATTIM >=

Page 38: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

HCSLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, causing call drops or more handovers. If this parameter is set to a small value, congestion occurs in macro cells.

BQSTATTIME BQ HO Watch Time

Meaning: According to the P/N rule, if the conditions for emergency BQ handover are met in P of N measurement reports, the handover is triggered.

This parameter specifies the number N.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 1

Recommended Value: 1

Page 39: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Parameter Relationship: This parameter is valid only when BQHOEN is set to YES and HOCTRLSWITCH is set to HOALGORITHM2. The following condition must be met: BQSTATTIME >= BQLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, unnecessary handovers are triggered. If this parameter is set to a small value, handovers cannot be performed in a timely manner, affecting voice quality or causing call drops.

BQLASTTIME BQ HO Valid Time

Meaning: According to the P/N rule, if the conditions for emergency BQ handover are met in P of N measurement reports, the handover is triggered.

This parameter specifies the number P.

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 1

Page 40: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Recommended Value: 1

Parameter Relationship: This parameter is valid only when BQHOEN is set to YES and HOCTRLSWITCH is set to HOALGORITHM2. The following condition must be met: BQSTATTIME >= BQLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, affecting voice quality or causing call drops. If this parameter is set to a small value, unnecessary handovers are triggered.

TASTATTIME TA HO Watch Time

Meaning: The P/N criterion must be met for triggering a TA handover. That is, the TA handovercan be triggered only if P measurement reports among N measurement reports meet the triggering conditions. This parameter corresponds to N in theP/N criterion.

GUI Value Range: 1~16

Unit: 0.5s

Page 41: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Actual Value Range: 0.5~0.8

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid only when TAHOEN is set to YES and HOCTRLSWITCH is set to HOALGORITHM2. The following condition must be met: TASTATTIME >= TALASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, an MS performs handovers frequently, leading to unnecessary handovers. If this parameter is set to a small value, an MS needs to wait a long time before performing a handover. As a result, voice quality deteriorates or the call drop rate increases.

TALASTTIME TA HO Valid Time

Meaning: The P/N criterion must be met for triggering a TA handover. That is, the TA handovercan be triggered only if P measurement reports among N measurement reports meet the triggering conditions. This parameter corresponds to P in the P/N criterion.

Page 42: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

GUI Value Range: 1~16

Unit: 0.5s

Actual Value Range: 0.5~8

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid only when HOCTRLSWITCH is set to HOALGORITHM2 and TAHOEN is set to YES. The following condition must be met: TASTATTIME >= TALASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, causing call drops. If this parameter is set to a small value, unnecessary handovers are triggered.

ULBQSTATTIME UL BQ HO Static Time

Meaning: Period during which handovers without a downlink measurement report are measured. According to the P/N rule, handovers without a downlink measurement report can be triggered

Page 43: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

when the conditions for handovers without a downlink measurement report are met for P seconds within N seconds. This parameter specifies N in the P/N rule.

GUI Value Range: 1~8

Unit: 0.5s

Actual Value Range: 0.5~4

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid only if HOCTRLSWITCH in the SET GCELLHOBASIC command is set to HOALGORITHM2(Handover algorithm II) and NODLMRHOEN in the SET GCELLHOEMG command is set to YES(Yes).The parameter value must meet the following requirement:ULBQSTATTIME >= ULBQLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Page 44: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Impact on Network Performance: If this parameteris set to a large value, unnecessary handovers are triggered. If this parameter is set to a small value, handovers cannot be performed in a timely manner, causing call drops.

ULBQLASTTIME UL BQ HO Last Time

Meaning: Period during which the conditions for handovers without a downlink measurement report. According to the P/N rule, handovers without a downlink measurement report can be triggered when the conditions for handovers without a downlink measurement report are met for P seconds within N seconds. This parameter specifies P in the P/N rule.

GUI Value Range: 1~8

Unit: 0.5s

Actual Value Range: 0.5~4

MML Default Value: 1

Recommended Value: 1

Parameter Relationship: This parameter is valid only if HOCTRLSWITCH in the SET GCELLHOBASIC command is set to HOALGORITHM2(Handover algorithm II) and NODLMRHOEN in the SET GCELLHOEMG command is set to YES(Yes).The parameter value

Page 45: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

must meet the following requirement:ULBQSTATTIME >= ULBQLASTTIME.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, handovers cannot be performed in a timely manner, causing call drops. If this parameter is set to a small value, unnecessary handovers are triggered.

IBCADYNCMEASURENCELLALLOWED

IBCA Dyn Measure Neighbour Cell Flag

Meaning: Flag that indicates whether an IBCA neighboring cell is to be measured dynamically. This parameter is set to Yes if the information about a neighboring cell cannot be reported through measurement reports but the interference of the neighboring cell cannot be ignored. Otherwise, this parameter is set to No. This parameter is set to Yes for the neighboring cell with co-channel interference and the neighboring cells that cause interference, while this parameter is set to No for other neighboring cells.

GUI Value Range: NO(No), YES(Yes)

Unit: None

Actual Value Range: NO, YES

Page 46: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

MML Default Value: NO(No)

Recommended Value: Set this parameter to YES for the neighboring cell with co-channel interference and the neighboring cell that cause interference; set this parameter to NO for other neighboring cells.

Parameter Relationship: This parameter is valid only if NCELLTYPE is set to IBCANCELL(IBCA Neighboring Cell) or HANDOVERANDIBCANCELL(Handover and IBCA Neighboring Cell).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

IBCARXLEVOFFSET IBCA RxLev Offset

Meaning: Unmeasured receive level of IBCA neighboring cells. If the number of neighboring cells reported in consecutive N measurement reports (N is specified by IBCANONMEANCELLSTATNUM) is smaller than that of the actually configured neighboring cells, this parameter is used to estimate the unmeasured receive level of IBCA neighboring cells. The estimated value is equal to the value of IBCANCELLPATHLOSSESTIMATE or the signal level of the unmeasured IBCA neighboring cells is the measured signal level of the neighboring cells (including non-IBCA neighboring cells) minus the value of IBCARXLEVOFFSET.

Page 47: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 4

Recommended Value: 4

Parameter Relationship: This parameter is valid only if NCELLTYPE is set to IBCANCELL(IBCA Neighboring Cell) or HANDOVERANDIBCANCELL(Handover and IBCA Neighboring Cell).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

LOADHOPBGTMARGIN Load HOPBGT Threshold

Meaning: Threshold for triggering load-based PBGT handovers. Load-based PBGT handovers to a candidate cell can be triggered when the path loss in the serving cell minus that in a candidate cell is greater than the value of this parameter. Thisparameter loosens the requirement of the load-based PBGT handover threshold when the load of

Page 48: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

the serving cell reaches a specified level. Certain traffic that could not be handed over back to a neighboring cell during PBGT handovers can be handed over now. If this parameter is set to 0, enhanced load-based handovers to the neighboringcell cannot be triggered.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: -64~63

MML Default Value: 0

Recommended Value: 0

Parameter Relationship: The parameter value cannot be larger than the value of PBGT HO Threshold. The parameter takes effect only when Enhanced Load HO Allowed is enabled.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a small value, unnecessary handovers are performed. If this parameter is set to a large value,

Page 49: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

handovers are delayed, increasing the congestion rate in the serving cell.

NCELLPRI Neighboring Cell Priority

Meaning: Common priority of the neighboring 2G cell. Value 0 indicates the lowest priority, and value 7 indicates the highest priority. Value 255 is invalid.

GUI Value Range: 0~7, 255

Unit: None

Actual Value Range: 0~7, 255

MML Default Value: 255

Recommended Value: None

Parameter Relationship: If this parameter is set to a value except 255, the value of this parameter must be different from the values of NCELLPRI of all neighboring UTRAN and EUTRAN cells, and UTRANPRI and EUTRANPRI of the serving cell.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Page 50: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Impact on Network Performance: None

EDOUTHOOFFSET Enhanced OutgoingCell Handover Offset

Meaning: Level offset for the serving cell when handovers to the edge of a neighboring cell are triggered.

When both Enhanced Outgoing Cell Handover Offset and EDGE HO Allowed are set to YES(Yes) for a cell, the BSC takes the value of this parameter into account when deciding to trigger an edge handover. That is, handovers to theedge of a neighboring cell can be triggered when either of the following condition is met:

Uplink receive level of the serving cell after powercontrol compensation < Value of ULEDGETHRES + Value of this parameter - 64

Downlink receive level of the serving cell after power control compensation < Value ofDLEDGETHRES + Value of this parameter - 64

In the case of Huawei handover algorithm II, handovers to a better neighboring cell can be triggered when both of the following conditions are met:

Enhanced Outgoing Cell Handover Offset is set to YES(Yes).

Receive level of the serving cell after power control compensation < Value of HOTHRES - (Value of LEVHOHYST + Value of this parameter - 64). The actual value of this parameteris equal to the GUI value minus 64.

GUI Value Range: 0~127

Page 51: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Unit: None

Actual Value Range: -64~63

MML Default Value: 64

Recommended Value: 64

Parameter Relationship: 1. This parameter is used with DLEDGETHRES or ULEDGETHRES to determine handovers to the edge of a neighboring cell only if both Enhanced Outgoing Cell Handover Offset and EDGE HO Allowed are set to YES(Yes). 2. This parameter is used with LEVHOHYST and HOTHRES to determine handovers to a better neighboring cell only if Enhanced Outgoing Cell Handover Offset is set to YES(Yes) and HOCTRLSWITCH is set to HOALGORITHM2(Handover algorithm II).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NCELLPUNEN Neighboring Cell Penalty Switch

Meaning: Whether to apply penalty on a neighboring cell when the PBGT handover, concentric cell handover, or hierarchical handover in handover algorithm I is triggered, or when the better cell handover in handover algorithm II is triggered. This prevents a call from experiencing

Page 52: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

ping-pong handovers.

GUI Value Range: NO(No), YES(Yes)

Unit: None

Actual Value Range: NO, YES

MML Default Value: NO(No)

Recommended Value: NO(No)

Parameter Relationship: 1. If HOCTRLSWITCHin the SET GCELLHOBASIC command is set to HOALGORITHM1, and PBGTHOEN, LEVHOEN, CONHOEN are set to YES, this parameter is valid. 2. If HOCTRLSWITCH in the SET GCELLHOBASIC command is set to HOALGORITHM2, and BETTERCELLHOEN is set to YES, this parameter is valid.

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NCELLPUNSTPTH Penalty Stop

Meaning: Level threshold used to stop the timer for performing penalties in a neighboring cell

Page 53: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Level Threshold

during the PBGT handover, concentric cell handover, or hierarchical handover in the case of Huawei handover algorithm I or during better cell handovers in the case of Huawei handover algorithm II.

If the BCCH receive level of the neighboring cell is lower than this threshold, the penalties will be stopped.

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 20

Recommended Value: 20

Parameter Relationship: This parameter is valid only if NCELLPUNEN is set to YES(Yes).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

Page 54: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

NCELLPUNTM Penalty Timer Length

Meaning: Length of the timer for performing penalties in a neighboring cell during PBGT, concentric cell handover, or hierarchical handoversin the case of Huawei handover algorithm I or during better cell handovers in the case of Huawei handover algorithm II.

GUI Value Range: 0~255

Unit: s

Actual Value Range: 0~255

MML Default Value: 10

Recommended Value: 10

Parameter Relationship: This parameter is valid only if NCELLPUNEN is set to YES(Yes).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

NCELLPUNLEV Level Penalty Value on

Meaning: Level for penalties in a neighboring cell during PBGT handover, concentric cell handover, or hierarchical handover in the case of Huawei

Page 55: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Neighboring Cell

handover algorithm I or during better cell handovers in the case of Huawei handover algorithm II.

GUI Value Range: 0~63

Unit: dB

Actual Value Range: 0~63

MML Default Value: 10

Recommended Value: 10

Parameter Relationship: This parameter is valid only if NCELLPUNEN is set to YES(Yes).

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: None

ADJHOOFFSET Quick Handover Offset for NeighborCell

Meaning: This parameter is used as the offset for HOOFFSET (for SET GCELLHOFAST in the case of internal neighboring cells or for MOD GEXT2GCELL in the case of external neighboring cells)during handover decision. Quickhandover can be triggered only when the path loss

Page 56: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

difference between the serving cell and a chain neighboring cell is larger than the quick handover trigger threshold. The quick handover trigger threshold is the sum of HOOFFSET(for SET GCELLHOFAST in the case of internal neighboring cells or for MOD GEXT2GCELL in the case of external neighboring cells) and ADJHOOFFSET configured by the neighboring cell.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: 0~127

MML Default Value: 0

Recommended Value: 0

Parameter Relationship: The sum of ADJHOOFFSET and HOOFFSET (for SET GCELLHOFAST in the case of internal neighboring cells or for MOD GEXT2GCELL in the case of external neighboring cells) should be less than or equal to 127. If the sum is greater than 127, it is processed as 127.

Service Interrupted After Modification: No (And

Page 57: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, call drops occur because the handover is not performed in a timely manner.

EDGEHOHYST Edge HOHysteresis

Meaning: Hysteresis used for an inter-cell handover decision when handover algorithm II is used. For an MS with low receive level, the receive level of the neighboring cell must be higher than the receive level of the serving cell plus the value of this parameter.

GUI Value Range: 0~127

Unit: dB

Actual Value Range: 0~127

MML Default Value: 68

Recommended Value: 67

Parameter Relationship: This parameter is valid only if EDGEHOHYSTEN in SET GCELLHOBASIC is set to YES(Yes). The value of this parameter must be less than or equal to INTERCELLHYST.

Page 58: Add 2G Neighbor Cell(ADD G2GNCELL)docshare02.docshare.tips/files/24306/243066766.pdf · Add 2G Neighbor Cell(ADD G2GNCELL) Function Use this command to add a 2G neighboring internal

Parameter ID Parameter Name

Parameter Description

Service Interrupted After Modification: No (And no impact on the UE in idle mode)

Impact on Network Performance: If this parameteris set to a large value, the number of handover requests sent by the MS with low receive level decreases. If this parameter is set to a small value, the number of handover requests sent by the MS with low receive level increases.

Example

To add a neighboring cell (IDTYPE = Index Type , Source Cell Name = Cell000, Neighbor 2G Cell Name = cell002; Inter-cell HO Hysteresis = 50; Min Access Level Offset = 60; Adjacent Cell Inter-layer HO Hysteresis = 68), run the following command:ADD G2GNCELL: IDTYPE=BYNAME, SRC2GNCELLNAME="Cell000", NBR2GNCELLNAME="cell002", NCELLTYPE=HANDOVERNCELL, INTERCELLHYST=50, MINOFFSET=60, INTELEVHOHYST=68;