August 29, 2016
ADDENDUM #1
NWIT#16-32 Sewer Separation Program
New Westminster, BC
This addendum modifies the Invitation to Tender only as noted: Please refer to Addendum No. 1 from Opus DaytonKnight Consultants Ltd (6 pages following) Please acknowledge this addendum as indication in the Form of Tender. END OF ADDENDUM #1 Yours truly,
Roy Moulder, SCMP Purchasing Manager
Draft Addendum #1
Page 1
CORPORATION OF THE CITY OF NEW WESTMINSTER
CONTRACT No. NWIT-16-32
2016 SEWER SEPARATION PROGRAM
ADDENDUM No. 1 (6 pages)
This Addendum shall form part of the Contract No. NWIT-16-32
A. Form of Tender: Schedule of Quantities and Prices
Payment items A1 and A2 have been amended.
New payment item A12 added to Section A- Storm Pipe.
Payment item B2 has been amended.
Replace FT-Page 4-5 with attached.
NOTE 1: For Storm Pipe 375 mm diameter or greater, HDPE is allowed.
NOTE 2: Payment item A12 has been added for the 200 mm storm service connection on Quebec Street.
NOTE 3: All Fibre Optic Pull Boxes to be SYNERTECH 2436-36, as per the attached product sheet.
B. Supplementary Specifications
Section 40 01 01S – Communication and Fibre Optic Conduits
Replace:
2.2 Plastic Junction Boxes .1 Plastic junction boxes to conform to the City
Supplementary Standard Drawing SD-C.2.
With:
2.2 Junction Boxes .1 Junction boxes shall be SYNERTECH 2436 Polymer
Concrete Boxes with 36” depth.
Page 2
Attach this Addendum to the Contract Documents.
Date: August 24, 2016
Addendum No. 1 received.
_______________________________ _______________________________
Signature of Tenderer Name of Tenderer (please print)
Encl. - FT Page 4-5
- SYNERTECH 2436 Product Sheet
OPUS DAYTONKNIGHT CONSULTANTS LTD. CITY OF NEW WESTMINSTER
#210 – 889 Harbourside Drive 511 Royal Avenue
North Vancouver, B.C. New Westminster, B.C.
V7P 3S1 V3L 1H9
(Addendum No. 1) FT PAGE 4
Tenderer’s Initials
MMCD 2009 Edition Reference No. NWIT-16-32
FORM OF TENDER – Appendix 1
SCHEDULE OF QUANTITIES AND PRICES (See paragraph 5.3.1 of the Instructions to Tenderers - Part II)
(All prices and Quotations including the Contract Price shall include all Taxes,
but shall not include GST. GST shall be shown separately.)
ITEM
NO.
MMCD
REF. DESCRIPTION UNIT QUANTITY
UNIT
PRICE AMOUNT
Section A – Storm Pipe
A1 33 40 01S Storm Pipe – 450 mm dia. DR35
PVC or HDPE, imported backfill
1.6.2
Park Row Lineal
147 metre
First Street Between Vancouver
Street & College Crt.
Lineal 153
metre
A2 33 40 01S Storm Pipe – 375 mm dia. DR35
PVC or HDPE, imported backfill.
1.6.2
First Street Between College Crt
& Emory Street
Lineal 173
metre
A3 33 40 01S Storm Pipe – 250 mm dia. DR35
PVC, imported backfill.
1.6.2
First Street Between Emory
Street & St. Patrick Street
Lineal 275
metre
College Crt. Lineal
20 metre
Emory Street Lineal
119 metre
Arbutus Street Lineal
143 metre
Fourth Avenue Lineal
metre 59
Oakland Street Lineal
51 metre
Queens Avenue Lineal
115 metre
Third Avenue Lineal
135 metre
Quebec Street Lineal
120 metre
Gloucester Street
Lineal 12
metre
Blackie Street
Lineal 62
metre
(Addendum No. 1) FT PAGE 5
Tenderer’s Initials
MMCD 2009 Edition Reference No. NWIT-16-32
ITEM
NO.
MMCD
REF. DESCRIPTION UNIT QUANTITY
UNIT
PRICE AMOUNT
A4 33 40 01S
1.6.9
Tie-in – 250mm dia. to existing
manhole (Park Row) Each 1
A5 33 40 01S
1.6.9
Tie-in – 250mm dia. to existing
stub (Gloucester St. at Ash St. &
Quebec St. at Eleventh St.)
Each 2
A6 33 40 01S
1.6.3 Service Connection – 100mm dia.
Lineal
metre 23
A7 33 40 01S
1.6.3 Service Connection – 150mm dia.
Lineal
metre 4.5
A8 33 44 01S Manhole base, lid, slab, cover
and frame – 1050 mm dia. Each 28
1.5.1.1
A9 33 44 01S
Manhole riser – 1050 mm dia. Vert.
metre 58
1.5.1.2
A10 33 40 01S Catchbasin – top inlet Std. Dwg.
S11. Each 30
1.6.5
A11 33 40 01S Catchbasin lead - 150 mm diam.,
all lengths. Each 30
1.6.5
A12 33 40 01S
1.6.3 Service Connection – 200mm dia.
Lineal
metre 3
Subtotal (Item A1 to A12)
Plus GST (5%)
TOTAL AMOUNT OF SECTION A
Section B – Fibre Optic Conduit
B1 40 01 01S Fibre Optic Conduit – 100 mm
dia.
1.3.1
Park Row Lineal
125 metre
First Street Between Vancouver
Street & Third Avenue
Lineal 569
metre
B2 40 01 01S Fibre Optic Pull Box –
SYNERTECH 2436-36 Each 6
1.3.2
Subtotal (Item B1 to B2)
Plus GST (5%)
TOTAL AMOUNT OF SECTION B
Section C – Optional Items
C1 32 12 16S Mill and Overlay – Mobilization
& Demobilization Each 2
1.5.9
C2 32 12 16S
Mill and overlay 35 mm depth Square
2060 1.5.8 metre
C3 31 23 17
Rock Removal Cubic
20 1.6.3 metre
Subtotal (Item C1 to C3)
Plus GST (5%)
TOTAL AMOUNT OF SECTION C
Contact your Oldcastle Enclosure Solutions Distribution Center for specific information and additional options.
oldcastleprecast.com/enclosuresolutions 800-735-5566
Revision 9/2014 ©2014 Oldcastle, Inc.
Electric & Communications
Material:Model:
Weight:
Wall Type:Performance:
DuoMold Composite24” x 36”18” Depth: 82 lbs24” Depth: 92 lbs36” Depth: 110 lbsStraightANSI/SCTE-77 Tier 22, WUC 3.6, ASTM C857 A-16
Bodies are stackable** to Depths of: 36”, 42”, 48”,60”, 72”
BODY:
COVER:
Style:Material:
Model:Weight:
Std. Fasteners:
Options:Surface:
Coefficient of Friction:Performance:
Flush SolidDuoMold Composite24” x 36”126 lbs1/2-13 Stainless Steel Hex Head Bolt, Self-Locating InsertLogos and Special MarkingsSlip Resistant & Marked*>0.6 ASTM 1028ANSI/SCTE-77 Tier 22, WUC 3.6, ASTM C857 A-16
2436
A B C D E F G
2436-18 38-1/8 26-1/2 18 23-1/2 35-1/4 29-1/8 17-1/2
2436-24 38-1/8 26-1/2 24 23-1/2 35-1/4 29-1/8 17-1/2
2436-36 38-1/8 26-1/2 36 23-1/2 35-1/4 29-1/8 17-1/2
* Cover comes standard with permanent markings for manufacturer, load rating, model size and manufacturing location.
For use in non-vehicular traffic situations only.
Heavy Duty: Incidental, Non-deliberate Traffic
Actual load rating is determined by the box and cover combination.Weights and dimensions may vary slightly**Stacked body units are currently not rated.
Options:
Product Load Rating:
Note: Actual load rating is determined by the box and cover combination. Weights and dimensions may vary slightly
Raw Material Specifications:
oldcastleprecast.com/enclosuresolutions 800-735-5566
Revision 9/2014 ©2014 Oldcastle, Inc.
Standard Test Method
Properties of Raw Material
ASTM Designation
TypicalValue
Compressive Strength of Polymer Concretes Compressive Strength C 469 > 17,000 psi
Flexural Properties of Plastic Materials Flexural Strength D 790 > 14,000 psi
Resistance of Plastics to Chemical Reagents Chemical Resistance Retain > 75% of original strength
Impact Resistance by Means of a Falling Weight Impact Resistance D 2444 > 70 ft-lb
Static Coef� cient of Friction Friction Coef� cient C 1028 > 0.6
ASTM Speci� cations shall be the current revision
Test Reports available on request
The Rural Utility Service (RUS) is a department of the US Department of Agriculture organized to facilitate rural developments. You will fi nd Oldcastle Enclosure Solutions brand enclosures listed by the RUS. All Oldcastle Enclosure Solutions brand enclosures conform to the RUS “Tamper Resistant” fastener design for buried pedestals.
All information contained on this sheet is current at the time of printing. Oldcastle Precast, Inc. reserves the right to discontinue or update product information without notice.
Electric & Communications
Available DuoMold Composite Covers:Flush Solid (Standard)
Fastener Options for DuoMold Composite Covers:Hex Head Bolt (Standard)
Penta Head Bolt
Oldcastle Enclosures Vandal Resistant Bolt
Add on Options:Larger Lift Hook Pocket
EMS Marker (E)
Mouseholes/Knockouts
Rack Mount (A)
Cable Racks/Cable Arms (B)
Unistrut (C)
Pulling Eye - 1,000 lb and 3,000 lb (D)
Ground Buss (F)
Dividers
Racking Provision
Lid Gaskets*
Solid Bottom
Bodies are Stackable (with tallest body on bottom)
*Lid Gaskets inhibit water flow into the box,they do not make Enclosure fully waterproof.
Heavy Duty : Incidental, Non-deliberate TrafficFor use in non-vehicular traffic situations only.
2436
Composite Cover
A B C D E F
Hex Head
Penta Head
Vandal
Resistant