addendum no. 1 - vancouver · 2017-03-21 · page 2 of 2 drawings attachment drawings for synertech...

2
FINANCE, RISK & BUSINESS PLANNING GROUP Supply Management City of Vancouver, Financial Services Group Supply Management 453 West 12th Avenue Vancouver, British Columbia V5Y 1V4 Canada tel: 604.873.7263 fax: 604.873.7057 website: vancouver.ca March 21, 2017 REQUEST FOR QUOTATIONS “RFQ” PS20170399 SUPPLY AND DELIVERY OF JUNCTION BOX ADDENDUM NO. 1 RE: Synertech Specification Drawings: PLEASE ADD: Polymer Concrete Boxes and covers shall be concrete gray and have a minimum vertical test load of 10,000 or 20,000 pounds. Covers shall have a minimum coefficient of friction of .50. The polymer concrete shall test to a minimum of 20,000 P.S.I. compressive strength and shall be suitable for installation and use through a temperature range of -40° C to +90° C. Polymer concrete parts shall be produced in steel molds to insure a consistent product. ASTM C-857 COVER TYPE COVER RATINGS LIVE LOAD 30% SAFETY TEST LOAD TEST AREA. Heavy duty 10 Ton GVW 8,000# 10,400# 22,568# 10" x 10" (20,000#) All covers exceed their rating by at least 20% and exceed ASTM test loads. No polymer concrete box or cover should be placed in a full traffic, H-20, application. Meets W.U.C. 3.6. Tier 22 specifications Underground Enclosures are designed to meet or exceed the tier loadings required by ANSI/SCTE 77 2002 “Specification for Underground Enclosure Integrity”. ANSI/SCTE tier designations are minimum specifications used by the industry to ensure the safe and reliable performance of underground manhole enclosures. Loading Requirements - Driveway, parking lot, railroad right of way and off-roadway applications subject to occasional non-deliberate heavy vehicular traffic. Vertical Load Rating 100.1 Kn 22,500 lbs Vertical Test Load 150.1 Kn 33,750 lbs Lateral Load Rating 38.3 Kpa 800 lbs/sq.ft Lateral Test Rating 57.5 Kpa 1200 lbs/sq.ft

Upload: others

Post on 19-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

FINANCE, RISK & BUSINESS PLANNING GROUP Supply Management

City of Vancouver, Financial Services Group Supply Management 453 West 12th Avenue Vancouver, British Columbia V5Y 1V4 Canada tel: 604.873.7263 fax: 604.873.7057 website: vancouver.ca

March 21, 2017

REQUEST FOR QUOTATIONS “RFQ” PS20170399 SUPPLY AND DELIVERY OF JUNCTION BOX

ADDENDUM NO. 1

RE: Synertech Specification Drawings:

PLEASE ADD:

Polymer Concrete Boxes and covers shall be concrete gray and have a minimum vertical test load of 10,000 or 20,000 pounds. Covers shall have a minimum coefficient of friction of .50. The polymer concrete shall test to a minimum of 20,000 P.S.I. compressive strength and shall be suitable for installation and use through a temperature range of -40° C to +90° C. Polymer concrete parts shall be produced in steel molds to insure a consistent product. ASTM C-857 COVER TYPE COVER RATINGS LIVE LOAD 30% SAFETY TEST LOAD TEST AREA. Heavy duty 10 Ton GVW 8,000# 10,400# 22,568# 10" x 10" (20,000#) All covers exceed their rating by at least 20% and exceed ASTM test loads. No polymer concrete box or cover should be placed in a full traffic, H-20, application. Meets W.U.C. 3.6.

Tier 22 specifications Underground Enclosures are designed to meet or exceed the tier loadings required by ANSI/SCTE 77 2002 “Specification for Underground Enclosure Integrity”. ANSI/SCTE tier designations are minimum specifications used by the industry to ensure the safe and reliable performance of underground manhole enclosures. Loading Requirements - Driveway, parking lot, railroad right of way and off-roadway applications subject to occasional non-deliberate heavy vehicular traffic. Vertical Load Rating 100.1 Kn 22,500 lbs Vertical Test Load 150.1 Kn 33,750 lbs Lateral Load Rating 38.3 Kpa 800 lbs/sq.ft Lateral Test Rating 57.5 Kpa 1200 lbs/sq.ft

Page 2: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Page 2 of 2

Drawings

Attachment Drawings for Synertech

RE: WCE Drawings:

PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing Table of the RFQ

Attachment MS200.1- Large Round Plastic Junction Box Isometric Assembly View  

PLEASE ADD: below additional drawing MS203.1 for WCE #370, Pricing Table of the RFQ

Attachment MS203.1- Small Round Plastic Junction Box Isometric Assembly View

This addendum must be completed, and attached to your Quotation form.

If you have already submitted your Quotation, this addendum shall be submitted to the Purchasing Services Office, City of Vancouver, 453 West 12th Avenue, Vancouver, British Columbia, Canada, V5Y 1V4, (Courier Delivery and Drop off is at the 4th floor, Supply Chain Management of the same address), prior to the Closing Time: 3:00:00 pm Local Vancouver, BC Time, in an envelope clearly marked “Addendum No. 1 to Request for Quotation No. PS20170399 SUPPLY AND DELIVERY OF JUNCTION BOX before the closing time of 3:00 p.m., Tuesday, April 11, 2017.

NAME OF VENDOR

SIGNATURE OF AUTHORIZED SIGNATORY

DATE

Jing Fan Buyer

Page 3: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Contact your Oldcastle Enclosure Solutions Distribution Center for specific information and additional options.

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

Electric & Communications

Material:Model:

Weight:

Wall Type:Performance:

DuoMold Composite11” x 18”12” Depth: 24 lbs18” Depth: 27 lbsStraightANSI/SCTE-77 Tier 15, WUC 3.6 ASTM C857 A-12

Bodies are stackable** to Depths of: 24”, 30”, 36”

BODY:

COVER:

Style:Material:

Model:Weight:

Std. Fasteners:

Options:Surface:

Coefficient of Friction:Performance:

Flush SolidDuoMold Composite11” x 18”26 lbs1/2-13 Stainless Steel Hex Head Bolt, Self-Locating InsertLogos and Special MarkingsSlip Resistant & Marked*>0.6 ASTM 1028ANSI/SCTE-77 Tier 15, WUC 3.6 ASTM C857 A-12

1118

A B C D E F G

1118-12 20-1/2 13-5/8 12 11-1/2 17-1/4 14-7/8 8

1118-18 20-1/2 13-5/8 18 11-1/2 17-1/8 14-7/8 8

* Cover comes standard with permanent markings for manufacturer, load rating, model size and manufacturing location.

For use in non-vehicular traffic situations only.

Medium Duty: Non-deliberate Traffic

Actual load rating is determined by the box and cover combination.Weights and dimensions may vary slightly**Stacked body units are currently not rated.

Page 4: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Standard Test Method

Properties of Raw Material

ASTM Designation

TypicalValue

Compressive Strength of Polymer Concretes Compressive Strength C 469 > 17,000 psi

Flexural Properties of Plastic Materials Flexural Strength D 790 > 14,000 psi

Resistance of Plastics to Chemical Reagents Chemical Resistance Retain > 75% of original strength

Impact Resistance by Means of a Falling Weight Impact Resistance D 2444 > 70 ft-lb

Static Coef� cient of Friction Friction Coef� cient C 1028 > 0.6

ASTM Speci� cations shall be the current revision

Test Reports available on request

The Rural Utility Service (RUS) is a department of the US Department of Agriculture organized to facilitate rural developments. You will fi nd Oldcastle Enclosure Solutions brand enclosures listed by the RUS. All Oldcastle Enclosure Solutions brand enclosures conform to the RUS “Tamper Resistant” fastener design for buried pedestals.

Options:

Product Load Rating:

Note: Actual load rating is determined by the box and cover combination. Weights and dimensions may vary slightly

Raw Material Specifications:

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

All information contained on this sheet is current at the time of printing. Oldcastle Precast, Inc. reserves the right to discontinue or update product information without notice.

Electric & Communications

Available DuoMold Composite Covers:Flush Solid (Standard)

Fastener Options for DuoMold Composite Covers:Hex Head Bolt (Standard)

Penta Head Bolt

Oldcastle Enclosures Vandal Resistant Bolt

Add on Options:Larger Lift Hook Pocket

EMS Marker (E)

Mouseholes/Knockouts

Rack Mount (A)

Cable Racks/Cable Arms (B)

Unistrut (C)

Pulling Eye - 1,000 lb and 3,000 lb (D)

Ground Buss (F)

Dividers

Racking Provision

Lid Gaskets*

Solid Bottom

Bodies are Stackable (with tallest body on bottom)

*Lid Gaskets inhibit water flow into the box,they do not make Enclosure fully waterproof.

Medium Duty : Non-deliberate TrafficFor use in non-vehicular traffic situations only.

1118

Composite Cover

A B C D E F

Hex Head

Penta Head

Vandal

Resistant

Page 5: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Contact your Oldcastle Enclosure Solutions Distribution Center for specific information and additional options.

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

Electric & Communications

Material:Model:

Weight:

Wall Type:Performance:

DuoMold Composite13” x 24”12” Depth: 32 lbs18” Depth: 36 lbs24” Depth: 40 lbsStraightANSI/SCTE-77 Tier 15, WUC 3.6 ASTM C857 A-12

Bodies are stackable** to Depths of: 30”, 36”, 42”

BODY:

COVER:

Style:Material:

Model:Weight:

Std. Fasteners:

Options:Surface:

Coefficient of Friction:Performance:

Flush SolidDuoMold Composite13” x 24”42 lbs1/2-13 Stainless Steel Hex Head Bolt, Self-Locating InsertLogos and Special MarkingsSlip Resistant & Marked*>0.6 ASTM 1028ANSI/SCTE-77 Tier 15, WUC 3.6 ASTM C857 A-12

1324

A B C D E F G

1324-12 25-3/4 16-1/8 12 14 21-5/8 19 9-1/2

1324-18 25-3/4 16-1/8 18-1/8 13-7/8 21-1/2 19 9-1/2

1324-24 25-3/4 16-1/8 24 13-7/8 21-1/2 19 9-1/2

* Cover comes standard with permanent markings for manufacturer, load rating, model size and manufacturing location.

For use in non-vehicular traffic situations only.

Medium Duty: Non-deliberate Traffic

Actual load rating is determined by the box and cover combination.Weights and dimensions may vary slightly**Stacked body units are currently not rated.

Page 6: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Options:

Product Load Rating:

Note: Actual load rating is determined by the box and cover combination. Weights and dimensions may vary slightly

Raw Material Specifications:

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

Standard Test Method

Properties of Raw Material

ASTM Designation

TypicalValue

Compressive Strength of Polymer Concretes Compressive Strength C 469 > 17,000 psi

Flexural Properties of Plastic Materials Flexural Strength D 790 > 14,000 psi

Resistance of Plastics to Chemical Reagents Chemical Resistance Retain > 75% of original strength

Impact Resistance by Means of a Falling Weight Impact Resistance D 2444 > 70 ft-lb

Static Coef� cient of Friction Friction Coef� cient C 1028 > 0.6

ASTM Speci� cations shall be the current revision

Test Reports available on request

The Rural Utility Service (RUS) is a department of the US Department of Agriculture organized to facilitate rural developments. You will fi nd Oldcastle Enclosure Solutions brand enclosures listed by the RUS. All Oldcastle Enclosure Solutions brand enclosures conform to the RUS “Tamper Resistant” fastener design for buried pedestals.

All information contained on this sheet is current at the time of printing. Oldcastle Precast, Inc. reserves the right to discontinue or update product information without notice.

Electric & Communications

Available DuoMold Composite Covers:Flush Solid (Standard)

Fastener Options for DuoMold Composite Covers:Hex Head Bolt (Standard)

Penta Head Bolt

Oldcastle Enclosures Vandal Resistant Bolt

Add on Options:Larger Lift Hook Pocket

EMS Marker (E)

Mouseholes/Knockouts

Rack Mount (A)

Cable Racks/Cable Arms (B)

Unistrut (C)

Pulling Eye - 1,000 lb and 3,000 lb (D)

Ground Buss (F)

Dividers

Racking Provision

Lid Gaskets*

Solid Bottom

Bodies are Stackable (with tallest body on bottom)

*Lid Gaskets inhibit water flow into the box,they do not make Enclosure fully waterproof.

Medium Duty : Non-deliberate TrafficFor use in non-vehicular traffic situations only.

1324

Composite Cover

A B C D E F

Hex Head

Penta Head

Vandal

Resistant

Page 7: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Contact your Oldcastle Enclosure Solutions Distribution Center for specific information and additional options.

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

Electric & Communications

Material:Model:

Weight:

Wall Type:Mouseholes:

Performance:

DuoMold Composite17” x 30”12” Depth: 42 lbs18” Depth: 50 lbs24” Depth: 58 lbsStraight0-4ANSI/SCTE-77 Tier 15, WUC 3.6 ASTM C857 A-12

Bodies are stackable** to Depths of: 30”, 36”, 42”, 48”

BODY:

COVER:

Style:Material:

Model:Weight:

Std. Fasteners:

Options:Surface:

Coefficient of Friction:Performance:

Flush SolidDuoMold Composite17” x 30”70 lbs1/2-13 Stainless Steel Hex Head Bolt, Self-Locating InsertLogos and Special MarkingsSlip Resistant & Marked*>0.6 ASTM 1028ANSI/SCTE-77 Tier 15, WUC 3.6 ASTM C857 A-12

1730

A B C D E F G

1730-12 33 20 12-1/8 17-3/4 30-3/4 26-1/4 13-1/4

1730-18 33 20 18-1/8 17-3/4 30-3/4 26-1/4 13-1/4

1730-24 33 20 24-1/8 17-3/4 30-3/4 26-1/4 13-1/4

* Cover comes standard with permanent markings for manufacturer, load rating, model size and manufacturing location.

For use in non-vehicular traffic situations only.

Medium Duty: Non-deliberate Traffic

Actual load rating is determined by the box and cover combination.Weights and dimensions may vary slightly**Stacked body units are currently not rated.

Page 8: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Options:

Product Load Rating:

Note: Actual load rating is determined by the box and cover combination. Weights and dimensions may vary slightly

Raw Material Specifications:

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

Standard Test Method

Properties of Raw Material

ASTM Designation

TypicalValue

Compressive Strength of Polymer Concretes Compressive Strength C 469 > 17,000 psi

Flexural Properties of Plastic Materials Flexural Strength D 790 > 14,000 psi

Resistance of Plastics to Chemical Reagents Chemical Resistance Retain > 75% of original strength

Impact Resistance by Means of a Falling Weight Impact Resistance D 2444 > 70 ft-lb

Static Coef� cient of Friction Friction Coef� cient C 1028 > 0.6

ASTM Speci� cations shall be the current revision

Test Reports available on request

The Rural Utility Service (RUS) is a department of the US Department of Agriculture organized to facilitate rural developments. You will fi nd Oldcastle Enclosure Solutions brand enclosures listed by the RUS. All Oldcastle Enclosure Solutions brand enclosures conform to the RUS “Tamper Resistant” fastener design for buried pedestals.

All information contained on this sheet is current at the time of printing. Oldcastle Precast, Inc. reserves the right to discontinue or update product information without notice.

Electric & Communications

Available DuoMold Composite Covers:Flush Solid (Standard)

Fastener Options for DuoMold Composite Covers:Hex Head Bolt (Standard)

Penta Head Bolt

Oldcastle Enclosures Vandal Resistant Bolt

Add on Options:Larger Lift Hook Pocket

EMS Marker (E)

Mouseholes/Knockouts

Rack Mount (A)

Cable Racks/Cable Arms (B)

Unistrut (C)

Pulling Eye - 1,000 lb and 3,000 lb (D)

Ground Buss (F)

Dividers

Racking Provision

Lid Gaskets*

Solid Bottom

Bodies are Stackable (with tallest body on bottom)

*Lid Gaskets inhibit water flow into the box,they do not make Enclosure fully waterproof.

Medium Duty : Non-deliberate TrafficFor use in non-vehicular traffic situations only.

1730

Composite Cover

A B C D E F

Hex Head

Penta Head

Vandal

Resistant

Page 9: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Contact your Oldcastle Enclosure Solutions Distribution Center for specific information and additional options.

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

Electric & Communications

Material:Model:

Weight:

Wall Type:Performance:

DuoMold Composite24” x 36”18” Depth: 82 lbs24” Depth: 92 lbs36” Depth: 110 lbsStraightANSI/SCTE-77 Tier 22, WUC 3.6, ASTM C857 A-16

Bodies are stackable** to Depths of: 36”, 42”, 48”,60”, 72”

BODY:

COVER:

Style:Material:

Model:Weight:

Std. Fasteners:

Options:Surface:

Coefficient of Friction:Performance:

Flush SolidDuoMold Composite24” x 36”126 lbs1/2-13 Stainless Steel Hex Head Bolt, Self-Locating InsertLogos and Special MarkingsSlip Resistant & Marked*>0.6 ASTM 1028ANSI/SCTE-77 Tier 22, WUC 3.6, ASTM C857 A-16

2436

A B C D E F G

2436-18 38-1/8 26-1/2 18 23-1/2 35-1/4 29-1/8 17-1/2

2436-24 38-1/8 26-1/2 24 23-1/2 35-1/4 29-1/8 17-1/2

2436-36 38-1/8 26-1/2 36 23-1/2 35-1/4 29-1/8 17-1/2

* Cover comes standard with permanent markings for manufacturer, load rating, model size and manufacturing location.

For use in non-vehicular traffic situations only.

Heavy Duty: Incidental, Non-deliberate Traffic

Actual load rating is determined by the box and cover combination.Weights and dimensions may vary slightly**Stacked body units are currently not rated.

Page 10: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing

Options:

Product Load Rating:

Note: Actual load rating is determined by the box and cover combination. Weights and dimensions may vary slightly

Raw Material Specifications:

oldcastleprecast.com/enclosuresolutions 800-735-5566

Revision 9/2014 ©2014 Oldcastle, Inc.

Standard Test Method

Properties of Raw Material

ASTM Designation

TypicalValue

Compressive Strength of Polymer Concretes Compressive Strength C 469 > 17,000 psi

Flexural Properties of Plastic Materials Flexural Strength D 790 > 14,000 psi

Resistance of Plastics to Chemical Reagents Chemical Resistance Retain > 75% of original strength

Impact Resistance by Means of a Falling Weight Impact Resistance D 2444 > 70 ft-lb

Static Coef� cient of Friction Friction Coef� cient C 1028 > 0.6

ASTM Speci� cations shall be the current revision

Test Reports available on request

The Rural Utility Service (RUS) is a department of the US Department of Agriculture organized to facilitate rural developments. You will fi nd Oldcastle Enclosure Solutions brand enclosures listed by the RUS. All Oldcastle Enclosure Solutions brand enclosures conform to the RUS “Tamper Resistant” fastener design for buried pedestals.

All information contained on this sheet is current at the time of printing. Oldcastle Precast, Inc. reserves the right to discontinue or update product information without notice.

Electric & Communications

Available DuoMold Composite Covers:Flush Solid (Standard)

Fastener Options for DuoMold Composite Covers:Hex Head Bolt (Standard)

Penta Head Bolt

Oldcastle Enclosures Vandal Resistant Bolt

Add on Options:Larger Lift Hook Pocket

EMS Marker (E)

Mouseholes/Knockouts

Rack Mount (A)

Cable Racks/Cable Arms (B)

Unistrut (C)

Pulling Eye - 1,000 lb and 3,000 lb (D)

Ground Buss (F)

Dividers

Racking Provision

Lid Gaskets*

Solid Bottom

Bodies are Stackable (with tallest body on bottom)

*Lid Gaskets inhibit water flow into the box,they do not make Enclosure fully waterproof.

Heavy Duty : Incidental, Non-deliberate TrafficFor use in non-vehicular traffic situations only.

2436

Composite Cover

A B C D E F

Hex Head

Penta Head

Vandal

Resistant

Page 11: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing
Page 12: ADDENDUM NO. 1 - Vancouver · 2017-03-21 · Page 2 of 2 Drawings Attachment Drawings for Synertech RE: WCE Drawings: PLEASE ADD: below additional drawing MS200.1 for WCE #530, Pricing