adelaide church renovation - city of providence€¦ · when the church was included on the most...
TRANSCRIPT
ADELAIDE CHURCH RENOVATION
126 ADELAIDE AVENUE PROVIDENCE, RI 02907PROVIDENCE ZONING
FEBRUARY 14, 2020
PAGE 2
ADELAIDE CHURCHEXISTING CONDITIONS
FRONT VIEW
ENTRY TOWER SPACE ADJACENT OF CHURCH TRANSEPT
EXISTING ROOF MASSING
PAGE 3
ADELAIDE CHURCHEXISTING CONDITIONS
STAINED GLASS WINDOW
STAINED GLASS WINDOW LOWER LEVEL FIREPLACE IN PROPOSED LOUNGE
STAINED GLASS WINDOW RELOCATED TO PROPOSED LOBBYORIGINAL PEW
PAGE 4
ADELAIDE CHURCH
CHURCH TRANSEPT WESTCHURCH TRANSEPT EAST
EXISTING CONDITIONS
PAGE 5
ADELAIDE CHURCHEXISTING CONDITIONS
VIEW FROM ADELAIDE AVE. VIEW FROM HAMILTON ST.
VIEW FROM HAMILTON ST. BACK OF CHURCH VIEW FROM EASTVIEW OF TOWER
PAGE 6
ADELAIDE CHURCHHISTORICAL CONTEXT & PROPOSED NARRATIVE
VIEW OF HOOD MEMORIAL CHURCH (1901, 1906-1907) FROM NORTHEAST | Photographer: Robert O. Christensen, 1979
VIEW FROM HAMILTON STREET
HOOD MEMORIAL AFRICAN METHODIST EPISCOPAL (A.M.E.)
PROPOSED NARRATIVE:
The Unitarians, who built this delightfully rambling complex in two stages moved here from a staunch Greek Revival temple designed and built by Warren, Tallman & Bucklin. The granite uncoursed rubble stone western section- Woodbury Memorial Chapel was built first, followed by ashlar sanctuary, This rambling stone complex, designed by Howard K. Hilton, is quite a switch in architectural expression, from the congregation’s urbanistically monumental former home to this nearly rural picturesque building. The latitude of belief within the Unitarian faith offers no immediate explanation for the formal choice found here. The Unitarians moved to East Greenwich in 1959, and a predominantly Swedish Methodist congregation occupied the building until 1977. Since then, this has been the religious home to Hood Memorial Church, a congregation first gathered in west Elmwood in the 1860s.
- 2003 Guide to Providence Architecture
When the church was included on the Most Endangered Properties list in 2014 and 2015, the building was unused and suffering from vandalism and structural damage. As of February 2019, the status is unknown.
- Guide to Providence Architecture
The Hood Memorial Church, designed by Howard K. Hilton, is a historically rich work of architecture in Providence’s Elmwood district. The following serves as a narrative of the existing condition of architectural elements and the proposed modifications to the building.
Our client has chosen to move forward with a design that retains and restores the building’s historic character along with proposed additions to it’s structure. Since it’s erection in 1901, the structure has seen significant damage and vandalism, that has contributed to the devolution that the building condition is in today.
ZDS proposes the following restoration and modifications:
• Interior fit out for 18 residential units• Restoration of all stone walls, pillars, and buttresses• Restoration of wooden clapboard siding as required• Restoration of all trim, dental, and moldings• Restoration and relocation of Eastern stained glass
window to Northern Facade• Replacement of Eastern and Southern stained glass
windows with clear glazing• Restoration of both chimneys• Replacement of entry doors• Addition of 16 space parking lot with bicycle parking• Construction of building sign in Northern yard• Construction of new brick walkways• Light-well addition• Three (3) dormer additions• Three (3) vertical additions on South side• Restoration of cathedral ceiling where indicated• Landscaping
PAGE 7
ADELAIDE CHURCHINSPIRATION
Disclaimer: To the best of our knowledge this information has been obtained by the latest resources available. This has NOT been verified or confirmed by the City of Providence or any State or Federal Agencies. Information regarding the overall size of the site has been obtained by using the scaled GIS mapping platform made available. It is highly encouraged that a class I survey be obtained for verification and that this information be reviewed with all governing authorities for confirmation prior to any property negotiations or financial transactions are completed.
PAGE 8
ADELAIDE CHURCH
ZONING DATA:
GENERAL: DESIGNATED ZONE - R-2 RESIDENTIAL DISTRICT, DETACHED SINGLE-FAMILY AND TWO-FAMILY, RESIDENTIAL DEV. OF MODERATE DENSITY, (400C)
OVERLAY ZONING DISTRICT - HD HISTORIC OVERLAY DISTRICT, (1100D);PLD = PROVIDENCE LANDMARK DISTRICT
HISTORIC DISTRICT COMMISSION (PHDC) AUTHORIZED TO REGULATE ALTERATION, REPAIR, CONSTRUCTION, DEMO, AND REMOVAL OF ANY EXTERIOR STRUCTURE AND/OR APPURTENANCE. (1104B)
USE: CURRENT USE = PLACE OF WORSHIPPROPOSED USE = DWELLING - MULTI-FAMILY, USE VARIANCE REQ’D (1201, TABLE 12-1)
LOT SIZE = 20,000 SFADELAIDE AVENUE FRONTAGE = 200 FHAMILTON STREET FRONTAGE = 100 F
PARKING: PARKING FOR DWELLING - MULTI-FAMILY, (1400, TABLE 14-1)VEHICLE SPACES = 1 PER DWELLING UNIT PERCENT COMPACT = 10% BICYCLE SPACES = 1 PER 5 DWELLINGS PERCENTAGE OF REQ’D BICYCLE SPACES THAT SHALL BE LONG TERM = 80%
ESTIMATED PARKING SPACES AVAILABLE = 16 SPACESESTIMATED BICYCLE SPACES AVAILABLE = 8 SPACESNUMBER OF UNITS = 18 UNITS TREE CANOPY: PERCENT REQUIRED: 30% OF LOT (1501-C)REQ’D TREE CANOPY = 6,000 SFLARGE - 1,000 SF MEDIUM - 700 SFSMALL - 300 SF
PROPOSED TREE CANOPY = 6,600 SF (2 LARGE, 4 MEDIUM, 6 SMALL)
SIGNAGE: FREESTANDING SIGN IN C-2 ZONE (1607 E, TABLE 16-1)MAX AREA = 20 SFMAX HEIGHT = 15 F
PROPOSED AREA = 20 SFPROPOSED HEIGHT = 6’0”Sources: Esri, HERE, Garmin, Intermap, increment P Corp., GEBCO, USGS, FAO, NPS, NRCAN, GeoBase, IGN, Kadaster NL, Ordnance Survey, Esri Japan,
METI, Esri China (Hong Kong), (c) OpenStreetMap contributors, and the GIS User Community, City of Providence, Department of Planning and Development
The information depic ted on this map is for planning purposes only.It is not adequate for legal boundary definition, regulatory interpretation, or parcel-level analyses.
Produced by the Prov idence Planning and Development GIS Lab.444 Westminis ter Street, Providence, R.I. 02903
Data Sources:Providence Geographic Information System
0 0.04 0.080.02mi
1 in ch = 167 feet
. PROVIDENCE, RHODE ISLAND
Date: 12/9/2019
DEPARTMENT OF PLANNING AND DEVELOPMENTJORGE O. ELORZA, MAYOR | BONNIE NICKERSON AICP, DIRECTOR
PROVIDENCE THE CREATIVE CAPITAL
N
LOCAL CONTEXT & ZONING DATA
PAGE 9
ADELAIDE CHURCHSITE SURVEY
Disclaimer: To the best of our knowledge this information has been obtained by the latest resources available. This has NOT been verified or confirmed by the City of Providence or any State or Federal Agencies. Information regarding the overall size of the site has been obtained by using the scaled GIS mapping platform made available. It is highly encouraged that a class I survey be obtained for verification and that this information be reviewed with all governing authorities for confirmation prior to any property negotiations or financial transactions are completed.
PAGE 10
ADELAIDE CHURCH
N
PROPOSED SITE PLAN SCALE @ 1/16” = 1’0” (20,000 S.F.)
1959 ADDITION
PAGE 11
ADELAIDE CHURCH
UP
UP
UP
CRAWL SPACE1962 SF
EXISTING FIREPLACE
EXISTING FIREPLACE
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/27
/202
0 9:
16:0
9 AM
126 ADELAIDE
BASEMENTFLOOR PLAN -EXISTING
A1.00
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 00 - BASEMENT LEVEL - EXISTING
EXISTING LOWER LEVEL PLAN SCALE @ 1/8” = 1’0”
N
FOOTPRINT = 7,380 SFNET SQ. FT. = 4,075 SF
PAGE 12
ADELAIDE CHURCH PROPOSED LOWER LEVEL PLAN (4,075 S.F.)SCALE @ 1/8” = 1’0”
N
UP
UP
UNEXCAVATED CRAWL SPACE
LIGHT WELL
UTILITY
COUNTER
287 SF
MICRO UNIT 1001
147 SF
LAUNDRY007
2303 SF
UTILITY000B
839 SF
LOUNGE000A
669 SF
MICRO UNIT 2002
517 SF
ONE BEDROOM UNIT 3003
529 SF
STUDIO UNIT 4004
24 SF
UTILITY100I
27 SF
UTILITY100J
EXISTING FIREPLACE
EXISTING FIREPLACE
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
3/10
/202
0 10
:49:
05 A
M
126 ADELAIDE
BASEMENTFLOOR PLAN
A 1.00
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 00 - BASEMENT LEVEL 0
PER FLOOR: MICRO UNITS = 2STUDIO UNITS = 1ONE BEDROOM UNITS = 1TWO BEDROOM UNITS = 0TOTAL = 4 UNITS
BUILDING TOTAL: MICRO UNITS = 4STUDIO UNITS = 3ONE BEDROOM UNITS = 10TWO BEDROOM UNITS = 1
TOTAL = 18 UNITS
PAGE 13
ADELAIDE CHURCH
DN
DN
UP
CROSSING
ALTER
EAST
TRAN
SEP
T
WES
T TR
AN
SEP
T
SUPPORT SPACE
SUPPORT SPACE
SUPPORT SPACE
SUPPORT SPACE
MULTI-PURPOSE SPACE
NAVE HALLENTRY
ENTRY
EXISTING FENCE
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
2/12
/202
0 4:
59:0
0 PM
126 ADELAIDE
FIRST FLOORPLAN -EXISTING
A1.01
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 01 - GROUND FLR LEVEL - EXISTING
EXISTING FIRST FLOOR PLAN (6,175 S.F.)SCALE @ 1/8” = 1’0”
N
PAGE 14
ADELAIDE CHURCH PROPOSED FIRST FLOOR PLAN (6,345 S.F.)SCALE @ 1/8” = 1’0”
UP
UP
UP
DN
1182 SF
ENTRY LOBBY100A
VESTIBULE100
556 SF
STUDIO UNIT 1101
590 SF
ONE BEDROOM UNIT 2102
107 SF
MAIL ROOM108
NotEnclosed
ONE BEDROOM UNIT 3103
562 SF
ONE BEDROOM UNIT 4104 704 SF
ONE BEDROOM UNIT 5105
538 SF
ONE BEDROOM UNIT 610619 SF
UTILITY100H
2' - 0"542 SF
MICRO UNIT107
LIGHT WELL
68' -
6 1
/4"
10' - 10"
9' -
8"
34' - 8"
11' -
2"
24' - 4" 24' - 0"
15' -
9"
22' -
0"
25' - 0"
8' -
0"
33' - 0"
27' -
3"
7' - 0"
100' - 10"
3' -
4"
15' - 0"3'
- 6
"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
3/10
/202
0 10
:43:
13 A
M
126 ADELAIDE
FIRST FLOORPLAN
A 1.01
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 01 - FLOOR 1
N
PER FLOOR: MICRO UNITS = 0STUDIO UNITS = 1ONE BEDROOM UNITS = 6TWO BEDROOM UNITS = 0TOTAL = 7 UNITS
BUILDING TOTAL: MICRO UNITS = 4STUDIO UNITS = 3ONE BEDROOM UNITS = 10TWO BEDROOM UNITS = 1
TOTAL = 18 UNITS
PAGE 15
ADELAIDE CHURCH
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/27
/202
0 9:
16:1
9 AM
126 ADELAIDE
SECOND FLOORPLAN -EXISTING
A1.02
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 02 - LOFT - EXISTING
EXISTING SECOND FLOOR PLAN (0 S.F.)SCALE @ 1/8” = 1’0”
N
PAGE 16
ADELAIDE CHURCH PROPOSED SECOND FLOOR PLAN (4,705 S.F.)SCALE @ 1/8” = 1’0”
UP
DN
OPEN TO BELOW
TWO BEDROOMUNIT 1
201
ONE BEDROOMUNIT 2
202
SITTING AREA (OPEN TO RESTORED STRUCTURE ABOVE)
(OPEN TO ENTRY LOBBY BELOW)
226 SF
MICRO UNIT 7207
UTILITY200B
LOBBY200A
584 SF
ONE BEDROOM UNIT 3203
OPEN TO BELOW
ONE BEDROOM UNIT 4204
485 SF
STUDIO UNIT 6206 247 SF
MICRO UNIT 5205
UTILITY200C
VESTIBULE200D
500 SF
950 SF
465 SF
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
2/13
/202
0 11
:13:
26 A
M
126 ADELAIDE
SECOND FLOORPLAN
A 1.02
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 02 - FLOOR 2
N
PER FLOOR: MICRO UNITS = 2STUDIO UNITS = 1ONE BEDROOM UNITS = 3TWO BEDROOM UNITS = 1TOTAL = 7 UNITS
BUILDING TOTAL: MICRO UNITS = 4STUDIO UNITS = 3ONE BEDROOM UNITS = 10TWO BEDROOM UNITS = 1
TOTAL = 18 UNITS
PAGE 19
ADELAIDE CHURCHNORTH ELEVATIONS SCALE @ 1/16” = 1’0”
EXISTING
PROPOSED
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
1A 4.00
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
2/12
/202
0 3:
32:5
1 PM
126 ADELAIDE
EXTERIORELEVATIONS
A 3.01
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 1 - NORTH ELEVATION
1/8" = 1'-0"2 2 - EAST ELEVATION
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/27
/202
0 11
:19:
50 A
M
126 ADELAIDE
EXTERIORELEVATIONS -EXISTING
A 3.03
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 A - NORTH ELEVATION - EXISTING
1/8" = 1'-0"2 B - EAST ELEVATION - EXISTING
RELOCATE EAST STAINED GLASS WINDOW TO NORTHERN FRONT FACADE.
DORMER ADDITION
DORMER ADDITION
LIGHT-WELL ADDITION
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
6"
BUILDING SIGN
9' -
3"
10' -
0"
AVER
AG
E G
RAD
E
40' -
0 +
/-
3' - 6"
2' -
8"
MICRO UNIT107
STUDIO UNIT004
3' -
2"
MICRO UNIT207
4' -
6"
23' -
0"
8"
LIGHT WELL
LIGHT WELL GRATE
EXISTING ROOF LINE
PROPOSED DORMER ROOF LINE
8' -
0"
+/-
8' -
9"
+/-
9' -
2"
+/-
4' -
6"
6' -
0" 01 - FIRST FLOOR
62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
6' -
8"
5' - 0"
6' -
8"
10' -
0"
9' -
3"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
2/13
/202
0 11
:15:
43 A
M
126 ADELAIDE
SECTIONS
A 4.00
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/4" = 1'-0"1 SECTION 1 - LIGHT WELL & DORMER1/4" = 1'-0"2 SECTION 2 - BACK STAIR
LIGHT WELL SECTION SCALE @ 1/8” =1’0”
PAGE 20
ADELAIDE CHURCHEAST ELEVATIONS SCALE @ 1/16” = 1’0”
EXISTING
PROPOSED
EXISTING
PROPOSED
WEST ELEVATIONS SCALE @ 1/16” = 1’0”
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
2/12
/202
0 3:
41:4
6 PM
126 ADELAIDE
EXTERIORELEVATIONS -EXISTING
A 3.03
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 A - NORTH ELEVATION - EXISTING
1/8" = 1'-0"2 B - EAST ELEVATION - EXISTING
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/27
/202
0 11
:19:
59 A
M
126 ADELAIDE
EXTERIORELEVATIONS -EXISTING
A 3.04
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 C - SOUTH ELEVATION - EXISTING
1/8" = 1'-0"2 D - WEST ELEVATION - EXISTING
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
1A 4.00
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
2/12
/202
0 3:
32:5
1 PM
126 ADELAIDE
EXTERIORELEVATIONS
A 3.01
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 1 - NORTH ELEVATION
1/8" = 1'-0"2 2 - EAST ELEVATION
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
2/12
/202
0 5:
16:3
2 PM
126 ADELAIDE
EXTERIORELEVATIONS
A 3.02
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 3 - SOUTH ELEVATION
1/8" = 1'-0"2 4 - WEST ELEVATION
EXISTING EAST WINDOW TO BE REPLACED, IN KIND WITH CLEAR GLAZING
DORMER ADDITIONSVERTICAL ADDITIONS
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/23
/202
0 11
:45:
27 A
M
126 ADELAIDE
EXTERIORELEVATIONS -EXISTING
A 3.03
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 A - NORTH ELEVATION - EXISTING
1/8" = 1'-0"2 B - EAST ELEVATION - EXISTING
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/27
/202
0 11
:19:
59 A
M
126 ADELAIDE
EXTERIORELEVATIONS -EXISTING
A 3.04
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 C - SOUTH ELEVATION - EXISTING
1/8" = 1'-0"2 D - WEST ELEVATION - EXISTING
VERTICAL ADDITIONS
PAGE 21
ADELAIDE CHURCH
EXISTING
PROPOSED
SOUTH ELEVATIONS SCALE @ 1/16” = 1’0”
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/27
/202
0 11
:19:
59 A
M
126 ADELAIDE
EXTERIORELEVATIONS -EXISTING
A 3.04
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 C - SOUTH ELEVATION - EXISTING
1/8" = 1'-0"2 D - WEST ELEVATION - EXISTING
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
3/10
/202
0 10
:49:
51 A
M
126 ADELAIDE
EXTERIORELEVATIONS
A 3.02
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 3 - SOUTH ELEVATION
1/8" = 1'-0"2 4 - WEST ELEVATION
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
01 - FIRST FLOOR62' - 9"
00 - LOWER LEVEL53' - 6"
02 - SECONDFLOOR72' - 9"
03 - T.O. ROOF95' - 9"
PROJECT NAME
PROJECT NO.
DRAWING NO.
SHEET TITLE
ISSUED DATE:
THESE DRAWINGS ARE FOR THE CONSTRUCTION OF THE PROJECT LISTED ABOVE AND ARE NOT TO BE COPIED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF ZDS, INC.
THE GENERAL CONTRACTOR SHALL NOT SCALE DRAWINGS FOR MEASUREMENTS, BUT SHALL VERIFY AT THE SITE ALL LEVELS AND MEASUREMENTS NECESSARY FOR COMPLETE FABRICATION, ASSEMBLY AND INSTALLATION OF THE WORK. MINOR DETAILS OF THE WORK NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE ASCERTAINED BY THE CONTRACTOR AT THE SITE OF THE WORK, AND SHALL BE ACCOMPLISHED WITH THE INTENT OF THIS PROJECT.
REVISIONS
PLO
T C
REA
TED
:
CONSULTANTS
CLIENT
ARCHITECT
ZDS inc.86 WEYBOSSET ST, SUITE 302
PROVIDENCE, RI 02903
+1.401.680.6699www.z-ds.com
STAMP
1/27
/202
0 11
:19:
59 A
M
126 ADELAIDE
EXTERIORELEVATIONS -EXISTING
A 3.04
DECEMBER 2019
126 ADELAIDE AVE,PROVIDENCE RI
SCHEMATICDESIGN
19150
NO DATE DESCRIPTION
1/8" = 1'-0"1 C - SOUTH ELEVATION - EXISTING
1/8" = 1'-0"2 D - WEST ELEVATION - EXISTING
EXISTING SOUTH WINDOW TO BE REPLACED, IN KIND WITH CLEAR GLAZING AND LOWER WINDOW ADDITION
DORMER ADDITION
VERTICAL ADDITION
VERTICAL ADDITION
VERTICAL ADDITION