Compaa Operadora de LNG del Per S.A.C.
Adjust GAP on radial vibration probes
Document Number:INT-0XX-WPL-XXXX
Document Owner:Maintenance
0Issued for UseAnonymous.
RevRevision DescriptionAuthorHSSE ReviewerReviewerApproverApproval Date
WngH&S Mgr.Production Supt.Production Mgr.
RevisionsApproval - Compaa Operadora de LNG del Per S.A.C.,
the operator of PERU LNG S.R.L.
1.0 Main Information
Document NumberINT-011-WPL-00Main Work CenterInstrumentation
System ConditionEquipment stoppedFrequency
Duration (hours)4.hr
2.0 Applicable forRefEquipment Tag NumberEquipment Description service
Radial vibration probe
3.0 HSE Considerations
Work Permit NameActivity
Safe Wok permitApply PTW one day before
4.0 ProcedureNOTE
Use proper PPE (disposable respirator, nitrile gloves, safety glasses, hard hat, and safety boots) as we will deal with chemicals such as corrosion transformer 763 (Chesterton).
STEPACTION
1.Apply permit to work.
2.Open permit to work.
3.Override / inhibit signals.
4.Disconnect probe extension cable.
5.Remove probe and check it.
6.Reinstate probe and check gap voltage adjusting in -10VDC.
7.Secure lock nut and reinstate extension cable.
8.Verify gap voltage on BN 3500 rack.
9.Close permit to work.
5.0 Special Tools
Special Tool DescriptionQuantityUnitsRemarks
Not Required
6.0 Spare Parts & Consumables
Material CodeMaterial DescriptionQuantityUnits
7.0 Manpower
DepartmentCraftNumberDuration (h)
InstrumentationInstrument Technician2
8.0 Reference Documents
Doc. NumberDocument Title