adtx threshold scan riken/rbrc itaru nakagawa 1. run13 adtx threshold scan march 3, 2013 muid1d...

20
ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1

Upload: magnus-obrien

Post on 17-Dec-2015

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

ADTX Threshold Scan

RIKEN/RBRCItaru Nakagawa

1

Page 2: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Run13 ADTX Threshold Scan

• March 3, 2013• MUID1D • HV=Run12 Nominal Setting• MuTrig e-Log entry=#1127

2

Page 3: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Run13 ADTX Threshold Scan Run# Threshold [mV] BBCnVTX [MHz] MUID1D

[events]ST-1 Logic

385751 40 1.39 6.5M AND2385752 60 1.36 4.5M AND2385753 20 1.34 1.6M AND2385754 10 1.32 1.3M AND2385755 100 1.31 2.7M AND2385756 80 1.29 1.6M AND2385757 80 1.27 1.8M OR385758 100 1.26 1.7M OR385759 60 1.25 0.5M OR385760 60 1.24 1.5M OR385761 40 1.23 1.6M OR385762 20 1.22 0.3M OR385763 10 1.22 0.5M OR

3

Page 4: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Fake Hit Rates (South)

Logic=AND2 Logic=OR Logic=OR

Octant-3 doesn’t necessarily stands out -> AND2 effect?

4

Page 5: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Sanghwa’s Gap-by-Gap Threshold Scan

Feb.2013

South St-1 Oct-2 Gap-2 Noisy

5

Page 6: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Fake Hit Rates (North)

Logic=AND2 Logic=OR Logic=OR

North Station-3 Octant-1 stands out

Vertical Axis : (average hits/strip)/total#of_trigger / 106ns [Hz]6

Page 7: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Inter Station Comparison (South)

7

Page 8: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Inter Station Comparison (North)

8

Page 9: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Accidental Coincidence Fake SG1 Trigger

• SG1 ~ R_st1 x R_st2 x R_st3

9

Page 10: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Accidental SG1 Prediction

10

Page 11: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Accidental SG1 Prediction

North Octant-1 Stands out, but not Octant-4

11

Page 12: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

SG1 Rate Octant Fraction (South)

Red Dot : EmulatorHorizontal Bar : Prediction from Fake Rates

Compares Actual SG1 Trigger Rates/oct from Emulatorand Prediction from Fake hit rates.

Run#385753 : Threshold=20mV

12

Page 13: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

SG1 Rate Octant Fraction (North)

Red Dot : EmulatorHorizontal Bar : Prediction from Fake Rates

Run#385753 : Threshold=20mV

Disagree more than 3sigma.Both plots are from same data. Why? Deadtime?

13

Page 14: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Inter Station Comparison (South)

14

Page 15: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Inter Station Comparison (North)

15

Normalized

Page 16: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Load Map to Threshold Optimization• Before Run13 : Thresholds are set to be constant

charge efficiencies.• Run13 Concept– R_oct1=R_oct2=R_oct3=…= R_oct8 – Raise threshold of station which has steeper response to

threshold regardless of noisy source St.• Analyze Charge efficiency– Eff_AND2 -> [1 - (1-eff_g1xeff_g2)x (1-eff_g3)]

• eff_g? = 0.9 => Eff_AND2=0.98

– Eff_OR -> [ 1- (1-eff)^2] • eff=0.9 => eff_OR=0.99

16

Page 17: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

Run12 Eff=95% Config

17

Page 18: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

BACKUP

18

Page 19: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

(Log)

19

Page 20: ADTX Threshold Scan RIKEN/RBRC Itaru Nakagawa 1. Run13 ADTX Threshold Scan March 3, 2013 MUID1D HV=Run12 Nominal Setting MuTrig e-Log entry=#1127 2

(log)

20