Page 1: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

GESensing

Advanced Modular Calibration System

AMCCombines an advanced multi-function calibrator with world-class pressure measurement and generation.

Page 2: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

2

System features

• Modularconceptprovidesgreaterflexibility

• Re-rangeduringuse

• Expandovertime

• Adaptbyapplication

• Allowssignificantinventoryreductions

• Simplifiesusertraining

• Reducescostofownership

Multifunction calibrator

• Accuracyfrom0.0025%rdg+0.002%FS

• Measure,sourceandsimulatemA,mV,V,ohms,frequency,RTDsandthermocouples

• HARTcommunication

• Easy-to-use,withvideoqualitytouchscreen

• HandheldPCversionwithWindowsCE

• USBandWiFiIEEE802.11gconnectivity

Pressuremeasurement

• 25mbarto1000bar(10inH2Oto15000psi)

• Accuracyfrom0.005%FS

• Fullyinterchangeablemoduleswithnoneedforset-up,calibrationortools

Modularity that brings a whole new perspective to multi-function test instruments and calibrators

Pressuregeneration

• Advancedpressuregeneration -95%vacuumto20barpneumatic -95%vacuumto100barpneumatic -0to1000barhydraulic

• Stand-alonepressurestationscanreplacehandpumps and can be used as comparators

Applications

• Instrumentationinstallation,commissioning,maintenance and calibration

• Systemmeasurementandmonitoring

• Indicator,recorderandcontrollertesting

• Processloopsetupanddiagnostics

• Switch,tripandsafetysystemtesting

For…

• Plantandprocessengineers

• Servicecompaniesandsitecontractors

• Installationandcommissioningengineers

• Laboratorytechnicians

Page 3: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

3

Features

• Multi-functioncapabilities:electrical,frequency,temperatureandpressure

• Modularre-rangeableandexpandableconcept

• Individualcomponentscanbeusedasstand-alone instruments

• Allowssignificantinventoryreductions

• Simplifiestrainingandimprovesoperator safety

• Reducescostofownership

Itsbasiccomponentisanultra-compact,electrical,frequencyandtemperaturecalibrator,whichprovidessimultaneousmeasurement and source capabilities.Pressuremeasurementisprovidedbyinterchangeable pressure modules thatcan be attached to the calibrator by a pressure module carrier.

Ifpressuregenerationisrequiredthecalibrator and pressure module canbe attached to one of three pressuregenerationstations,toformafully-integratedpressurecalibrator,of unparalleled performance.

Thesimpleyetsophisticateddesignandconceptcombines,forthefirsttime,an advanced electrical calibrator withstate-of-the-art pressure measurementandgeneration,sothatthereisnolongerany need to compromise one measurandcapability in favour of another.

Aflexiblemodularsystem

Re-rangeablepressuremeasurementandgenerationfrom25mbar(10inH2O)to1000bar(15000psi)

The Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring a wide range of different instruments.

Re-rangeabledualchannelpressuremeasurementfrom25mbar(10inH2O)to1000bar(15000psi)

MeasureandsourcemA,mV,V,ohms,frequency,RTD’sand thermocouples.

Page 4: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

4

TheDPI620AdvancedModular Calibrator

Features

•Measure,sourceandsimulatemultipleparameters

•HARTdigitalcommunicator

•Easy-to-use,withvideoqualitytouchscreen,whichcanbeoperated by a gloved hand

•Weather-prooftoIP65

•Candisplayupto6activereadings

•Availablewitharangeofadd-onmodules,pressuremeasurementmodulesandgenerationstations,IntecalFieldCalibrationdocumentingmodule,300Vacmeasurementprobe

• Digitalinterfaceforpressuremodulesandfutureoptions

•USBmasterandslaveforconnectingtoaPCandperipherals

•AvailableinWindowsCEversion

•Long-lifeLithium-Polymerbatterypack

ACompactandPowerfulElectricalCalibrator

TheDP620electricalcalibratorcanmeasureandsourcemA,mV,V,Ohms,frequencyandavarietyofRTDsandT/Cs.Itprovidesanisolated24Vlooppowersupplytoenergisedevicesand control loops and a stabilized dc voltage supply for ratio metrictransducers.AHARTdigitalcommunicatorisprovidedforset-upandcalibrationadjustmentofHARTdevices.

Thehighresolution,colourtouchscreenofthecalibratorshowsonlythosebuttonsnecessaryfortheimmediate,selectedtasks.Thebuttonshavebeensizedsothattheycanbeoperatedbyaglovedhand,withnoneedforastylus.Thedisplaycanbeconfiguredtoshowuptosixreadingwindowsandeachwindowcanshowanelectricalinput/output,pressure,temperature,aUSB-connecteddeviceorawireless-connecteddevice.Thereadingwindowsalsoactasactivekeysand,whenpressed,theyexpandtoshowmoredetailedinformationortoprovideadvance functions such as step and ramp outputs. Colour is used toemphasizeimportantinformation,forexample,redforcriticalor failed values and green for pass or within tolerance.

TheDPI620includescomprehensivedocumentingfeaturesforautomating instrument calibration when used in conjunction with IntecalCalibrationManagementsoftware.

Thecompactandlightweightcalibratorisdesignedforrugged

fieldapplication,witharobustcasingandweather-proofingto IP65.Itfeaturesahigh-speeddigitalinterfaceforconnectingtopressuremodulesandpressuregeneratingstations.Thisinterfacewillalsoallowexpansiontomeetfuturerequirementswhennewmodulesandstationsbecomeavailable.ItalsofeaturesUSBandoptionalwirelessconnectivityandamicroSDcardslotformemoryexpansion.

TheDPI620CEAdvancedModular CalibratorA Multifunction Electrical Calibrator withWindowsCE

TheWindowsCE-drivenversionoftheelectricalcalibratorprovidesallthecomputingpowerofaconventionalhand-heldPCorPDA.ItprovidesstandardWindowsfilemanagementandofferspopularWindowsfeaturestoallowtheusertoviewpdffiles,videofilesandjpegimages.Thismeansthatoperatorscanconsultusermanuals,trainingvideos,datasheets,installationdrawingsetcwhileinthefieldorontheplant.

TheDPI620CEWiFi Advanced Modular CalibratorAMultifunctionElectricalCalibratorwithWindowsCEandWiFiConnectivity

TheDPI620CEversioncanbefurtherenhancewithwirelessIEEE802.11gcommunications.Forthefirsttime,inacalibratorofthistype,itispossibletolinktotheInternetandremotenetworksinordertoaccessinformationandtotransferdata.Thispowerfulfeaturewillbenefitservicetechnicianswhospendextendedperiodsawayfromheadofficeandforthosewhoneedinstantaccesstodata,safetyinformation,systemdrawings,productdatasheetsetc.,whileonthemove.Itwillalsoprovideaninterfaceto future system modules when a physical connection is a hindrance.

Page 5: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

5

Page 6: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

6

Electrical Measurement and SourceNLH&R±1°C(2°F)for24hrs(note1)

TotalUncertainty10°to30°C(50°to86°F) for1year

Additional error -10°to10°C(14°to50°F)30°to50°C(86°to122°F)

Resolution Displayreadingwindow

%Rdg +%FS %Rdg +%FS %Rdg/°C +%FS/°CMeasure modeDCVoltage Thermocouple PleaserefertoThermocouplespecificationtable CH1

TCmode-10to100mV 0.009 0.008 0.014 0.01 0 0.0005 0.001 CH10to200mV 0.0045 0.004 0.007 0.005 0 0.0005 0.001 CH1 CH20to2000mV 0.004 0.003 0.007 0.005 0 0.0005 0.01 CH1 CH20to20V 0.0025 0.002 0.01 0.002 0 0.0005 0.00001 CH1 CH20to30V 0.0035 0.0035 0.01 0.004 0 0.0005 0.0001 CH1 CH2

ACVoltage 0to2000mVAC 0.125 0.125 0.2 0.15 0.005 0.005 0.1 CH1(note2) 0to20VAC 0.1255 0.125 0.2 0.15 0.005 0.005 0.001 CH1

0to300VAC 1 0.06 1.5 0.1 0.05 0.005 0.01 CH1Current 0to20mA 0.006 0.005 0.012 0.006 0 0.0005 0.0001 CH1 CH2

0to55mA 0.005 0.005 0.016 0.005 0 0.0005 0.0001 CH1 CH2Resistance RTD PleaserefertoRTDspecificationtable CH1(4wire) 0to400Ω 0.012 0.005 0.015 0.006 0 0.0005 0.001 CH1

0to4000Ω 0.0115 0.0045 0.015 0.006 0 0.0005 0.01 CH1Frequency 0to1000Hz 0.003 0.0002 0.003 0.0002 0.0001 CH1

1kHzto50kHz 0.003 0.0004 0.003 0.0004 0.00001 CH10to999999CPM Refertoequivalentfrequency 0.01 CH10to999999CPH Refertoequivalentfrequency 0.01 CH1Triggerlevel Automaticandadjustable0to20V 0.1

Pressure 25mbarto1000bar (0.35psitot15000psi)

PleaserefertoPM620pressurerangetable P1 P2

IDOSexternalmodule PleaserefertoIDOSUPMdatasheet.CableP/NIO620-IDOS-USBrequired IDOSUSBport PleaserefertoGESensingforcompatibledevices USB

Source modeDCVoltage TCmode PleaserefertoThermocouplespecificationtable

TCmode-10to100mV 0.009 0.008 0.014 0.01 0 0.0005 0.001 CH10to200mV 0.0045 0.004 0.007 0.005 0 0.0005 0.1 CH10to2000mV 0.004 0.003 0.007 0.005 0 0.0005 0.1 CH10to12V 0.006 0.0035 0.01 0.0035 0 0.0005 0.001 CH1

Current 0to24mA 0.01 0.004 0.015 0.005 0 0.0005 0.001 CH1 CH20to24mA(24Vlooppower) 0.01 0.004 0.015 0.005 0 0.0005 0.001 CH224Vlooppower 24V±10%

Resistance RTD PleaserefertoRTDspecificationtable CH10to400Ω(0.1mA) 0.024 0.0035 0.03 0.0075 0 0.0005 0.01 CH10to400Ω(0.5mA) 0.004 0.0025 0.008 0.003 0 0.0005 0.01 CH1400to2000Ω(0.05mA) 0.048 0.0035 0.06 0.006 0 0.0005 0.01 CH12kto4kΩ(0.05mA) 0.048 0.0035 0.06 0.0045 0 0.0005 0.01 CH1Maximuminputcurrent 0-400Ω5mA,400-2000Ω1mA,2000-4000Ω0.5mA

Frequency 0to1000Hz 0.003 0.00023 0.003 0.00023 0.1 CH11kHzto50kHz 0.003 0.000074 0.003 0.000074 0.001 CH1Output waveform Square,positiveswingupto12V(adjustable),negativeswing-80mV(fixed)

SineandTriangular,adjustableamplitudeandoffsetwithinthelimits-2.5to+12VSquarewavepeakoutput 0to12V+/-20mV(10mAmaximum)0to99999CPM Pleaserefertoequivalentfrequency 1 CH10to99999CPH Pleaserefertoequivalentfrequency 1 CH1

TechnicalSpecificationsGeneral SpecificationsDisplay Size:110mm(4.3in)diagonal;480x272pixels

LCD:Colourdisplaywithtouch-screenLanguages English{Default}Operating temperature -10°to50°C(14°to122°F)Storage temperature -20°to70°C(-4°to158°F)IngressProtection IP65(Dust-tight,jetsofwater)Humidity 0to90%withoutcondensation(DefStan66-31,8.6catIII)Shock/Vibration BSEN61010:2001;DefStan66-31,8.4catIIIEMC Electromagneticcompatibility:BSEN61326-1:2006Electrical safety Electrical–BSEN61010:2001Pressuresafety PressureEquipmentDirective-Class:SoundEngineeringPractice(SEP)Approved CEMarkedSize(L:W:H) DPI620only:183x114x42mm(7.2x4.5x1.7in)+MC620:≈265x114x64mm(10.4x4.5x2.5in)

+PM620:≈265x114x93mm(10.4x4.5x3.7in)Weight DPI620only:≈575g(1.3lb)–batteryincluded.MC620only:≈640g(1.4lb).PM620only:≈100g(0.2lb).Powersupply Lithium-Polymerbattery(GEPartnumber:IO620-Battery);Capacity:5040mAh(minimum),5280mAh(typical);Nominalvoltage:

3.7V.Chargetemperature:0°to40°C(32°to104°F)Dischargetemperature:-20°to60°C(-4°to140°F). Note: For best battery performance, keep the temperature less than 60°C (140°F). Charge/dischargecycles:>500>70%capacity.

Duration Measurefunctions(CH1):≈12hourscontinuous.DualFunction,mAmeasure(CH2):≈7hours(24VSourceat12mA)

Page 7: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

7

* Applicable to 4 wire connection

**0.1mAmin,0-400Ωand0.05mAmin,400-4000Ω

Excitationcurrent:measuremode0.5mA,sourcemode0to400Ω5mAmax,0.4to2kΩ1mAmaxand2to4kΩ0.5mAmax

Pulsedexcitationcurrentminimumduration10ms

SpecificationsrelatetoDPI620uncertaintiesonly

Note1:NLH&R(non-linearity,hysteresisandrepeatability)specificationapplieswhencalibrationtemperatureisbetween10and30°C(50°Fand86°F).

Note2:Specificationappliesbetween10%and100%of fullscale.

Multiple parameter display capability.

Thedisplaycanbeconfiguredtoshowamaximumof6simultaneousreadingwindowsasfollows:CH1,CH2,P1,P2,IDOS,USB

5

6

6 SpecificationsrelatetoDPI620uncertaintiesonly

ColdJunction(CJ)Error(maximum)

Range:10to30°C(50to86°F)=0.2°C(0.4°F)

Add0.01°C(0.02°F)CJError/°ambienttemperaturechangeforranges:-10to10°C,30to50°C(14to50°F,86to122°F)

RTD Measurement and SimulationType Standard Temperaturerange

(rangeshowscorrectresolution)TotalUncertainty10°to30°C(50°to86°F)for1year

Reso-lution

°C °F *Measure **SimulateFrom To From To °C °F °C °F

Pt50 IEC751(385)

-200.00 0.00 -328.00 32.00 0.20 0.36 0.30 0.54 0.010.00 850.00 32.00 1562.00 0.30 0.54 0.50 0.90 0.01

Pt100 IEC751(385)

-200.00 0.00 -328.00 32.00 0.14 0.25 0.22 0.40 0.010.00 760.00 32.00 1400.00 0.25 0.45 0.40 0.72 0.01

760.00 850.00 1400.00 1562.00 0.80 1.44 1.00 1.80 0.01Pt100 (392) -200.00 0.00 -328.00 32.00 0.13 0.23 0.22 0.40 0.01

0.00 760.00 32.00 1400.00 0.25 0.45 0.38 0.68 0.01760.00 850.00 1400.00 1562.00 0.80 1.44 1.00 1.80 0.01

Pt200 IEC751(385)

-200.00 0.00 -328.00 32.00 0.10 0.18 0.18 0.32 0.010.00 260.00 32.00 500.00 0.11 0.20 0.20 0.36 0.01

260.00 850.00 500.00 1562.00 0.50 0.90 0.82 1.48 0.01Pt500 IEC751

(385)-200.00 0.00 -328.00 32.00 0.20 0.36 0.34 0.61 0.01

0.00 850.00 32.00 1562.00 0.30 0.54 0.80 1.44 0.01Pt1000 IEC751

(385)-200.00 0.00 -328.00 32.00 0.14 0.25 0.31 0.56 0.01

0.00 400.00 32.00 752.00 0.17 0.31 0.45 0.81 0.01D100 JIS

1604-1989-200.00 0.00 -328.00 32.00 0.10 0.18 0.16 0.29 0.01

0.00 480.00 32.00 896.00 0.14 0.25 0.24 0.43 0.01480.00 650.00 896.00 1202.00 0.51 0.92 0.70 1.26 0.01

Ni100 DIN43760 -60.00 0.00 -76.00 32.00 0.07 0.13 0.12 0.22 0.010.00 250.00 32.00 482.00 0.09 0.16 0.17 0.31 0.01

Ni120 MINCO7-120

-80.00 0.00 -112.00 32.00 0.07 0.13 0.15 0.27 0.010.00 260.00 32.00 500.00 0.10 0.18 0.16 0.29 0.01

Cu10 -200.00 0.00 -328.00 32.00 0.65 1.17 0.85 1.53 0.010.00 260.00 32.00 500.00 0.65 1.17 0.85 1.53 0.01

Thermocouple Measurement and SimulationType Standard Temperaturerange

(rangeshowscorrectresolution)TotalUncertainty10°to30°C(50°to86°F)for1year

Resolution

°C °F °C °FFrom To From To

B IEC584 250.00 500.00 482.00 932.00 4.00 7.20 0.01500.00 700.00 932.00 1292.00 2.00 3.60 0.01700.00 1200.00 1292.00 2192.00 1.50 2.70 0.011200.00 1820.00 2192.00 3308.00 1.00 1.80 0.01

E IEC584 -270.00 -200.00 -454.00 -328.00 2.00 3.60 0.01-200.00 -120.00 -328.00 -184.00 0.50 0.90 0.01-120.00 1000.00 -184.00 1832.00 0.25 0.45 0.01

J IEC584 -210.00 -140.00 -346.00 -220.00 0.50 0.90 0.01-140.00 1200.00 -220.00 2192.00 0.30 0.54 0.01

K IEC584 -270.00 -220.00 -454.00 -364.00 4.00 7.20 0.01-220.00 -160.00 -364.00 -256.00 1.00 1.80 0.01-160.00 -60.00 -256.00 -76.00 0.50 0.90 0.01-60.00 800.00 -76.00 1472.00 0.30 0.54 0.01800.00 70.00 1472.00 158.00 0.50 0.90 0.01

L DIN43710 -200.00 -100.00 -328.00 -148.00 0.40 0.72 0.01-100.00 900.00 -148.00 1652.00 0.25 0.45 0.01

N IEC584 -270.00 -200.00 -454.00 -328.00 7.00 12.60 0.01-200.00 -40.00 -328.00 -40.00 1.00 1.80 0.01-40.00 1300.00 -40.00 2372.00 0.40 0.72 0.01

R IEC584 -50.00 360.00 -58.00 680.00 3.00 5.40 0.01360.00 1760.00 680.00 3200.00 1.00 1.80 0.01

S IEC584 -50.00 70.00 -58.00 158.00 3.00 5.40 0.0170.00 320.00 158.00 608.00 1.50 2.70 0.01320.00 660.00 608.00 1220.00 1.10 1.98 0.01660.00 1740.00 1220.00 3164.00 1.00 1.80 0.01

T IEC584 -270.00 -230.00 -454.00 -382.00 3.00 5.40 0.01-230.00 -50.00 -382.00 -58.00 1.00 1.80 0.01-50.00 400.00 -58.00 752.00 0.30 0.54 0.01

U DIN43710 -200.00 -50.00 -328.00 -58.00 0.60 1.08 0.01-50.00 600.00 -58.00 1112.00 0.30 0.54 0.01

C 0.00 1600.00 32.00 2912.00 0.80 1.44 0.011600.00 2000.00 2912.00 3632.00 1.00 1.80 0.012000.00 2300.00 3632.00 4172.00 1.40 2.52 0.01

D 0.00 100.00 32.00 212.00 1.10 1.98 0.01100.00 270.00 212.00 518.00 0.80 1.44 0.01270.00 1200.00 518.00 2192.00 0.60 1.08 0.011200.00 1800.00 2192.00 3272.00 0.80 1.44 0.01

Page 8: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

8

PM620Pressure ModulesFeatures

•Fullyinterchangeablewithnoneedforset-uporcalibration

•Simplescrewfit–notoolsrequired

•Rangesfrom25mbarto1000bar(10inH2Oto15000psi)

•Accuracyfrom0.005%FS

ThePM620isthelatestdevelopmentindigitaloutputsensortechnologyincorporatinganumberofkeyinnovationstoallowpressurere-rangingofcompatibleequipment.Asimplescrewfitmakesboththepressureandelectricalconnectionswithouttheneedfortools,sealingtape,cablesorplugsanddigitalcharacterisation allows intercahngeability without set-up orcalibration.Themodulescanbechangedinafewsecondstore-range an instrument at a fraction of the cost of a new one.ThepressuremodulescanbeusedinconjunctionwiththerelevantpneumaticorhydraulicpressurestationandtheDPI620multifunction calibrator to form an integrated pressure calibratorfor test and calibration of pressure instruments includingtransmitters,transducers,switches,gauges,indicatorsandrecorders.Alternatively,themodulescanbecombinedwiththepressurestationbyamodulecarrier,whichaddsadualchannelpressure measurement capability that can be re-ranged in seconds.

Pressurerangesareavailablefrom25mbarto1000bar(10inH2O to15000psi)withatotalmeasurementuncertainty,includingoperationover0to50o C(32to122°F)foroneyear.

MC620Module CarrierFeatures

• 2independentpressurechannels

• Simpletore-range

• Notoolsorsetup–justasimplescrewfit

• Pressureprotection

TheMC620modulecarrierattachestheheadoftheDPI620toprovidetwoindependentpressuremeasurementchannels.ThesecanbefittedwithanyPM620pressuremoduleform25mbarto1000bar(10inH2Oto15000psi).Asimplescrewfitmeansnotools are required and ensures both a high integrity pressure seal and a reliable digital interface.

Thepressureconnectiontothedeviceundertestisasimplefingertightsystemwithinterchangeableadaptors.Thistool-lessconnectionmethodisquicktouseandprovidesahighintegrityseal.Thesamesystemisusedontheinterconnectinghoseandadaptoraccessories,suchthattheonlyconnectionrequiring toolsandseals/sealingtapeisthefinalconnectiontothedeviceunder test.

Thecarrierisalsodesignedforpressuresafetyandwillautomaticallysealifamoduleisnotfittedoriftheuserattemptsto remove it.

MC 620 SpecificationMaximumpressure 400bar(5800psi)pneumatic

1000bar(15000psi)hydraulicPressuremedia Compatible with stainless steel and nitrile

sealsPressuresafety PressureequipmentdirectiveclassSEPSize and weight 80mmx100mmx110mm,640g

Page 9: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

9

PM 620 SpecificationMaximumintermittentpressure 2xFSMaximumworkingpressure 110%FSSealing IP65(protectedagainstdustand

jetsofwater)Operating temperature -10to50°C(14to122°F)Storage temperature -20to70°C(-4to158°F)Humidity 0to90%withoutcondensation

(Defstan66-31,8.6catIII)Shockandvibration BSEN61010:2001;Defstan66-31,

8.4catIII)EMC BSEN61326-1:2006Electrical safety BSEN61010:2001Pressuresafety Pressureequipmentdirectiveclass

SEPApproval CEmarkedSize and weight 100mmx65mmx48mm,100g

Gauge Ranges (referenced to atmosphere)Media NLH&R

20°C±2°C(68°F±4°F)

24 hr

NLH&R0°to50°C

(32°to122°F)24 hr

Totaluncertainty 0°to50°C

(32°to122°F)for1year

Gauge Gaugebar psi %FS %FS %FS±0.025 ±10inH2O ➊ 0.090 0.090 0.100±0.07 ±1 ➊ 0.025 0.030 0.047±0.2 ±3 ➊ 0.020 0.027 0.045±0.35 ±5 ➋ 0.020 0.025 0.044±0.7 ±10 ➋ 0.015 0.020 0.041±1 -14.5to15 ➋ 0.015 0.020 0.041-1to2 -14.5to30 ➋ 0.015 0.020 0.025-1to3.5 -14.5to50 ➋ 0.010 0.020 0.025-1to7 -14.5to100 ➋ 0.010 0.020 0.025-1to10 -14.5to150 ➋ 0.005 0.020 0.025-1to20 -14.5to300 ➋ 0.005 0.020 0.0250to35 0to500 ➋ 0.005 0.020 0.0250to70 0to1000 ➋ 0.005 0.020 0.0250to100 0to1500 ➋ 0.005 0.020 0.0250to135 0to2000 ➋ 0.005 0.020 0.0250to200 0to3000 ➋ 0.005 0.020 0.025

Absolute Ranges (referenced to vacuum)Media NLH&R

20°C±2°C (68°F±4°F)

24 hr

NLH&R 20°C±2°C (68°F±4°F)

24 hr

NLH&R 0°to50°C (32°to122°F)

24 hr

NLH&R 0°to50°C (32°to122°F)

24 hr

Totaluncertainty 0°to50°C

(32°to122°F) for1year

Absolute **Sealed Gauge

Absolute **Sealed Gauge

Absolute **Sealed Gauge

bar psi %FS %FS %FS %FS *%FS %FS0to0.35 0to5 ➋ 0.030 0.050 0.0800to1.2 0to35inHg ➋ 0.020 0.036 0.0700to2 0to30 ➋ 0.015 0.036 0.0520to3.5 0to50 ➋ 0.015 0.036 0.0500to7 0to100 ➋ 0.015 0.036 0.0500to10 0to150 ➋ 0.015 0.005 0.030 0.020 0.047 0.0250to20 0to300 ➋ 0.015 0.005 0.030 0.020 0.047 0.0250to35 0to500 ➋ 0.015 0.005 0.030 0.020 0.047 0.0250to70 0to1000 ➋ 0.015 0.005 0.030 0.020 0.047 0.0250to100 0to1500 ➋ 0.015 0.005 0.030 0.020 0.046 0.0250to135 0to2000 ➋ 0.015 0.005 0.030 0.020 0.046 0.0250to200 0to3000 ➋ 0.015 0.005 0.030 0.020 0.046 0.0250to350 0to5000 ➋ 0.015 0.005 0.033 0.020 0.049 0.0250to700 0to10000 ➋ 0.015 0.005 0.033 0.020 0.049 0.0250to1000 0to15000 ➋ 0.015 0.005 0.033 0.020 0.049 0.025

NLH&RNon-linearity,hysteresisandrepeatability➊ Compatiblewithnon-corrosivegas/fluid➋ Compatible with stainless steel* Average over two years** Thereadingcanbereferencedtoambientair pressureviaasoftwarefeatureoftheDPI620DPI620pressureresolution:99999

5

4

Page 10: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

10

ThePV621,622and623PressureStationsFeatures

•Auniquelycapable,re-rangeableandselfcontainedpressuretest system

•Advancedpressuregeneration

-95%vacuumto20bar(300psi)pneumatic

-95%vacuumto100bar(1500psi)pneumatic

-0to1000bar(15000psi)hydraulic

• Standalonereplacementsforhandpumps

• Benchtopuseascomparators

Therearethreepressuregenerationstations:thePV621,apneumaticpressuregeneratorforpressures95%vacuumto20bar(300psi);thePV622,apneumaticpressuregeneratorforpressures95%vacuumto100bar(1500psi);andthePV623,ahydraulicpressuregeneratorforpressuresupto1000bar (15000psi).Eachpressurestationisdesignedforstand-aloneoperation as a pressure generator and can replace conventional handpumpstoprovidegreaterefficiency,easeofuseandsignificantlyreducetheriskofrepetitivestraininjuries.Theycanalsobeusedontheworkbenchasacomparators.

ThePV621hasaconventionalhandpump,volumeadjusterandpressure/vacuumselector,butwillgeneratepressurewithhalftheeffort of conventional systems.

ThePV622100bar(1500psi)pneumaticstationrepresentsafive-foldincreaseincapabilityandsolvesthetransportationandEHSissuesofusinggasbottlesandregulatorsasapressuresourceinfieldlocations.Itfeaturesaninnovativedualstagesystem incorporating a hand pump to generate pressure and a screwpresstointensifythepressure.Foratypical4”gauge

mountedonthestation,100bar(1500psi)canbeachievedinjustonecycle,buttheprocesscanberepeatedasmanytimesasrequiredforhighervolumesystems.Thescrewpressconvertstoa precision volume adjuster allowing the test pressure to be increased or decreased as required.

ThePV623solvesmanyoftheproblemsassociatedwithhydraulicpressuregenerationbygeneratingpressureto1000bar(15000psi)intovirtuallyanyvolumewithouttheneedforsystemprimingandbyprovidingastablepressurewithin1minute.Inconventional systems priming to remove air is wasteful and messy and pressure stability is only achieved after several minutes.Thisinstabilityistheresultofthermalchange,seenasalargepressureleak,whichcanrenderthedeviceunusableforcalibrationfor10minutesperpressuretest.

OperationofthePV623issimple.Thescrewpressisrotatedanti-clockwisetodrawairoutofthetestdevice.Thesameactionfillsthescrewpresswithhydraulicfluidfromaninternalreservoir.Thescrewpressisthenrotatedclockwisetofillthetestdeviceandcompressthehydraulicfluid.Forlargervolumesystemstheprocesscanberepeated,anon-returnvalvepreventspressurelossontherefillcycle.Whenthetestpressurehasbeenreachedthe screw press converts to a precision volume adjuster for makingfineadjustments.

CombininganyofthepressurestationswithaPM620pressuremoduleandtheDPI620calibratorcreatesauniquelycapable,self-contained pressure calibrator.

PV 621, 622 and 623 SpecificationMaximumpressure PV62120bar(300psi)pneumatic

PV622100bar(1500psi)pneumaticPV6231000bar(15000psi)hydraulic

Pressuremedia PV621andPV622non-corrosivegases, PV623de-mineralizedwaterormineraloil (ISOviscositygrade<22)

Operating temperature Forwater+4to+50°C(39to122°F)Storage temperature -20to70°C(-4to158°F)(mustbeemptyofwater)Shockandvibration BSEN61010:2001;Defstan66-31,8.4catIIIPressuresafety PressureequipmentdirectiveclassSEPSize and weight 450mmx280mmx235mm,

PV6212.65kg,PV6223.30kg,PV6233.75kg

PV 621 PV 622PV 623

Page 11: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

11

Page 12: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

12

OrderingInformationPleaseorderthefollowingmodelnumbersandpartnumbersasseparate line items.

Model DPI 620Advanced modular calibratorModel DPI 620 CEAdvancedmodularcalibratorwithWindowsCEModel DPI 620 CE WIFIAdvancedmodularcalibratorwithWindowsCEandWiFi

TheDPI620/CE/WIFIaresuppliedwitharechargeablelithiumpolymerbatteryP/NIO620-BATTERY,universalmainsadaptor/chargerP/NIO620-PSU,testleads,calibrationcertificate,quickreferenceguideandCDwithmultilingualusermanuals.

Model MC 620PressuremodulecarrierSuppliedwithG1/8femaleand1/8NPTfemaleadaptors(2ofeach).

Model PM 620 “pressure range” and “type”Pressuremodule.Suppliedwithcalibrationcertificate.Eg.PM62020bar(300psi)gauge

Model PV 621Pneumaticpressurestation20bar(300psi)Model PV 622Pneumaticpressurestation100bar(1500psi)Model PV 623Hydraulicpressurestation1000bar(15000psi)

ThePV621,622and623aresuppliedwithG1/8femaleand1/8NPTfemaleadaptors,carrystrap,quickreferenceguideandCDwithmultilingualusermanual.InadditionthePV623includesaplasticbottleforhydraulicfluid.

DPI620MultifunctionCalibrator AccessoriesIntecalBasic(P/N781-016-B)

Developedtomeetthegrowingdemandonindustrytocomplywithqualitysystemsandcalibrationdocumentation.DevicetestproceduresarecreatedinaWindows®basedapplicationandareallocatedtoworkordersfortransfertotheDPI620.TheproceduresconfiguretheDPI620parameters,automaticallymanageAsFoundandAsLeftcalibrationsandreporttheresultswithPass/Failstatus.ResultsareuploadedtothePCforarchivingandtoprintcalibrationcertificates.

IntecalAdvanced(P/N781-016-A)

BuildsontheconceptofIntecalBasicsupportingbothportablecalibratorsandon-lineworkshopinstruments.Intecalissimple-to-usecalibrationmanagementsoftware,whichenablesahighproductivityofscheduling,calibrationanddocumentation.

IntecalFieldCalibrationManager (P/NIO620-FIELD-CAL)

ThissoftwaremoduleaddsthegeneralfeaturesofIntecalcalibrationmanagementsoftwaretotheDPI620allowingnewdevicerecordsandprocedurestobecreatedinthefieldwhilegivingaccesstofullhistoricaldata.ItworksseamlesslywiththedocumentingcapabilityoftheDPI620toautomatefieldcalibration and fully integrates with the master database of Intecal.Thismoduleisidealforfieldservicetechnicianswhospendextendedperiodsawayfromtheheadofficeorforthosewho need full database access when out on the plant. Complete sectionsoftheIntecaldatabase,containingallthedevicedetails,proceduresandhistoricalrecordsformultipleworklocations,canbetransferredtotheDPI620orsplitbetweenmultipleDPI620sforlargerteams.Thistransferofdataandtheeventualsynchronizing of the master database can be achieved in a numbersofways;SDmemorycard,USBmemorystick,USBcableandviaWiFiconnectivitytotheinternetandremotenetworks.

For more information on Intecal and a 30 day free trial visit www.gesensing.com

ACvoltagemeasurementprobe(P/NIO620-AC)

AttachestotheDPI62030Vsocketstoprovide300VACtruermsmeasurement.

Carryingcase(P/NIO620-CASE-1)

Aprotectivefabriccarryingcasewithbeltloop,shoulderstrapandlargepocketfortestleadsandaccessories.

Systemcarryingcase(P/NIO620-CASE-2)

Attaché style carrying case for system components including the DPI620,MC620,PM620modules,testleads,hoseandadaptors.

Lithiumpolymerrechargeablebattery (P/NIO620-BATTERY)

Spare/replacementbatteryfortheDPI620.

Batterychargingstation(P/NIO620-CHARGER)

ThisexternalbatterychargerallowsasparebatterytobechargedindependentlyoftheDPI620forminimuminstrumentdowntime.Powerisprovidedbythestandardmainsadaptor.Acompletechargecycletakesapproximately4hours.Simultaneously,theDPI620canbeconnectedviaaUSBcabletoprovideatop-upcharge(fullchargein12hours).

Mainsadaptor(P/NIO620-PSU)

AspareuniversalmainsadaptorforusewithDPI620andIO620-CHARGER.Inputvoltage100to240VAC50/60Hz.Mainssocketadaptorsareprovided.

Page 13: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

13

Pneumatichosekit

Ahighpressurepneumatichoseratedto400bar(5800psi). ToollessquickfittothePV621,PV622andMC620pressureports.TerminatedwithaquickfitconnectorcompatiblewiththetestpointadaptorssuppliedwiththePV62X,MC620andtheadaptor sets.P/N IO620-HOSE-P1: 1metrepneumatichosekitP/N IO620-HOSE-P2: 2metrepneumatichosekit

DPI620Hydraulichosekit

Ahighpressurehydraulichoseratedto1000bar(15000psi). ToollessquickfittothePV621,PV622andMC620pressureports.TerminatedwithaquickfitconnectorcompatiblewiththetestpointadaptorssuppliedwiththePV62X,MC620andtheadaptor sets.P/N IO620-HOSE-H1:1metrehydraulichosekitP/N IO620-HOSE-H2:2metrehydraulichosekit

Pressureadaptorset

AsetoftestpointadaptorstoconnectthetoollessquickfitPV62X,MC620andtheextensionhosestothedeviceundertest.P/N IO620-BSP: G1/8,G1/4,G3/8andG½femaleP/N IO620-NPT:1/8”,¼”,3/8”,and½”femaleP/N IO620-MET: 14mmand20mmfemale

Comparatoradaptor(P/NIO620-COMP)

AllowsthePV62Xpressurestationtobeusedasacomparator.Theadaptorconnectstothestationspressureportandprovidestwooutletportsformakinggaugecomparisons..Compatible withthetestpointadaptorssuppliedwiththePV62Xandtheadaptors sets.

Blankingplug(P/NIO620-BLANK)AllowsthePV62XtobeusedasapressuregeneratorindependentlyoftheDPI620andPM620byblankingthePV62Xpressure module port.

USBcable(P/NIO620-USB-PC)

ConnectstheDPI620toaPC.

IDOStoUSBconversioncable (P/NIO620-IDOS-USB)

AllowsconnectionofanIDOSuniversalpressuremoduletotheDPI620.

USBtoRS232cable(P/NIO620-USB-RS232).

ConnectstheDPI620toanRS232interface.

PV621,622,623andMC620AccessoriesPressurereliefvalve

WhenfittedtoaPV62XpressurestationprotectsthePM620pressure module and the device under test from overpressure.

Pressurestationcarryingcase (P/NIO620-CASE-3)A protective fabric carrying case with shoulder strap and large pocketforaccessories.AlsoaccommodatestheassemblesystemincludingtheDPI620andPM620.

Modularsystemtransitcase(P/NIO620-CASE-4)

Arigidtransitcasewithwheelsandanextendablehandle.AccommodatestwoPV62Xpressurestations,DPI620,MC620andPM620modules,withamplestoragespaceforaccessories.

Partnumber Forusewith Factorysetting

Adjustable range

bar psi bar psiIO620-PRV-P1 PV621PV622 1 15 0.4to1 6to15IO620-PRV-P2 PV621PV622 7 100 3to7 45to100IO620-PRV-P3 PV621PV622 30 435 15to30 220to435IO620-PRV-P4 PV622 60 870 30to60 435to870IO620-PRV-P5 PV622 100 1500 50to100 725to1500IO620-PRV-H1 PV623 50 725 10to50 145to725IO620-PRV-H2 PV623 200 3000 50to200 725to2900IO620-PRV-H3 PV623 400 6000 200to400 2900to5800IO620-PRV-H4 PV623 700 10000 300to700 4350to10000IO620-PRV-H5 PV623 1000 15000 600to1000 8700to15000

Page 14: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

14

Supporting ServicesGESensingprovidesServicestoenhance,supportandcomplement the AMC product range. Our highly trained staff can supportyou,nomatterwhereyouareintheworld.

PressuremeasurementtrainingGESensing’strainingandeducationprogramofferscomprehensive standard and customized curricula focusing on operation,application,maintenanceandtechnology.ForAMCuserswerecommendthe3dayPrinciplesofAutomatedPressureCalibrationTrainingcourse.Thisisregularlydeliveredandclassescanbeheldatvariouslocations,yourlocalfacilityorthroughon-linedelivery.Qualitytrainingenablesyourengineers&technicianstooptimizeyourbusiness’performance.

Nationally accredited calibrationNewproductissuppliedwithfactorycalibrationcertificateswithmeasurementstraceablebacktointernationalstandards.Forapplications where initial nationally accredited calibration certificatesarerequiredorperiodicre-calibrationisdesiredGEsensing can provide the solution.

ExtendedwarrantytermsNewproductissuppliedwithanindustrybenchmarkedinitialwarranty.Forpeaceofmind,improvedcostpredictabilityandIncreasedassurance,extendcoverageonyourequipmentbyupto5yearsterm.

Multi-year calibration and repair services agreements Available forcontrollers&calibrators,multi-yearserviceagreementsincreasecostpredictabilitybyprovidingfixedratesforextendedperiods.Withlargerscopeundertakingscustomizedplanscanbeadapted to your needs.

RentalGE’srentalprogramoffersasimple,quickandaffordablesolutionforunexpectedmeasurementneed.Rentalsallowcustomerstobe fully operational when challenges that are not foreseen arise. Assistingourcustomersinmeetingpeakdemands,unexpectedsituations,evaluationsandalsotominimisedowntimeofimportantprocessesawiderangeofmeasurement,testandcalibrationequipmentisavailableonashort-termrentalbasis…from pressure indicators to portable calibrators and sophisticated airdatatestsystems.Therentalfleetisavailablefrominventory,Factorytested&calibratedwithaminimumrentalperiodonly1week.Withlargerscopeundertakingsanyproductcanbemadeavailable for rental.

MaintenanceShould your equipment need maintenance our global repair facilitiesarehappytoserve.Workisconductedbytrainedapprovedtechnicians,usingcontrolledoriginalequipmentpartsandproceduressorestoringtheproducttodesigncondition.Thisisparticularlyimportantfortheperformanceexpectationsandadvanced features incorporated in the AMC range. Should you wishtoconductyouownmaintenanceanumberofspareskitsare available to facilitate this.

ServicesOrderingInformationPleaseorderthefollowingasseparatelineitems.

IO620-CAL-ELECDPI620Multifunctioncalibratoraccreditedelectricalcalibration.

IO620-CAL-PRESSPM620Pressuremoduleaccreditedcalibration.

IO620-WTY-3Extendedwarrantytoprovidethreeyearsofcover.Pleasestatetheequipmenttobecoveredbytheagreement e.g.DPI620,PM620,andPV621.

IO620-WTY-5Extendedwarrantytoprovidefiveyearsofcover.Pleasestatetheequipmenttobecoveredbytheagreement e.g.DPI620,PM620,andPV621.

IO620-CALREP-3Threeyearserviceagreementcoveringcalibrationandminorrepairs.Pleasestatetheequipmenttobecoveredbytheagreemente.g.DPI620,PM620,andPV621.

IO620-CALREP-5Fiveyearserviceagreementcoveringcalibrationandminorrepairs.Pleasestatetheequipmenttobecoveredbytheagreemente.g.DPI620,PM620,andPV621.

Page 15: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

15

AboutUSGE has united the technological innovation andexperienceofindustryleadersinthedesignandmanufacture of advanced sensing andmeasurement solutions into one world-classbusiness—GE Sensing.

GE’ssensingproductsmeasuretemperature,pressure,liquidlevel,moistureandhumidity,gasconcentration,andflowrateforapplicationsrangingfromenvironmental,medical,andpharmaceuticaltoautomotive,aerospace,chemical,andpetrochemical.

Fromhigh-qualityhand-heldandportablefieldcalibrators to stand-alone measurementinstrumentsandsystems,GESensingprovidesend-to-endsolutionsthatcanhelpyoumonitor,protect,andcontrolyourcriticalprocessesandapplications.

Pressure

Flow

Temperature

Gas

Moisture

Humidity

Level

Page 16: Advanced Modular Calibration System - InstrumartThe Advanced Modular Calibration System uses three basic components to provide the multi-functionality to perform duties formerly requiring

www.gesensing.com

2008GE.Allrightsreserved.BR-173A