Advanced neutron monitoring with fissionchambers
Zsolt Elter
SNEC meeting, 2016. June
IntroductionHigher Order Campbelling
Wrap up
Self-introPhD work
Short intro of myself
I From Hungary, 28 years old
I BSc in physics: Budapest University ofTechnology (MCNP simulations ofgeophysics density measurement probe)
I MSc in physics: Budapest University ofTechnology (MCNP simulations ofAllegro gas cooled fast reactor)
I Researcher at the Atomic EnergyResearch Institute + CEA internship(Eranos calculations; participate indiffusion code development)
I PhD: at Chalmers (2.5 years spent atCEA Cadarache) supervised byImre Pazsit (2012-)
Zs. Elter Advanced neutron monitoring 2/10
IntroductionHigher Order Campbelling
Wrap up
Self-introPhD work
Neutron flux monitoring
I Online flux measurement inASTRID: fission chamber
I Stochastic electric signal on theelectrodes
I 3 different processing modes (anddifferent electronics)
I Pulse mode (low flux)I Campbelling (medium flux)I Current mode (high flux)
I High order Campbelling (HOC) forunifying Pulse and Campbellmodes? + Simple measurementsystem with self-monitoringcapability?
Zs. Elter Advanced neutron monitoring 3/10
IntroductionHigher Order Campbelling
Wrap up
Self-introPhD work
Fission chamber signal - Numerical Matlab calculationsI The signal is considered as sum of pulses with exponentially
distributed arrival times (Poisson Pulse Train, shotnoise)
I Interest: unfold the count rate from the signal. Processingmethods?
Zs. Elter Advanced neutron monitoring 4/10
IntroductionHigher Order Campbelling
Wrap up
Numerical studiesExperimental studiesSmart detector
Higher order Campbell mode, HOC
I Linearity gap between Pulse and Campbell mode (Zs. Elter et al. NIMA
Vol. 774 p60-67 (2015))
I Generalization of Campbell mode(L. Pal et al. NIMA Vol. 768. p44-52 (2014))
I Relationship between the cumulants of the signal with and thecount rate s0 (for pulses with random amplitude)
κn = s0〈xn〉+∞∫−∞
f (t)ndt (1)
I Normal distribution κn = 0 n > 2
I The cumulants are estimated from a finite sample
I Calibration coefficient: known in a simulation, but otherwise?
Zs. Elter Advanced neutron monitoring 5/10
IntroductionHigher Order Campbelling
Wrap up
Numerical studiesExperimental studiesSmart detector
Main numerical results - HOC mode
I n = 3 order is satisfactory (above not plausible)
I Convergence in short measurement times (1− 10ms)
I Most common noises are suppressedI Transient events can be monitored (when s(t))
Zs. Elter et al. NIMA Vol. 813 p10-12 (2016) & Zs. Elter et al. NIMA Vol. 821 p66-72 (2016)
Zs. Elter Advanced neutron monitoring 6/10
IntroductionHigher Order Campbelling
Wrap up
Numerical studiesExperimental studiesSmart detector
Experimental work - HOC Calibration I.
Goal: Cn = 〈xn〉+∞∫−∞
f (t)ndt
Zs. Elter Advanced neutron monitoring 7/10
IntroductionHigher Order Campbelling
Wrap up
Numerical studiesExperimental studiesSmart detector
Experimental work - HOC Calibration II. Zs. Elter et al. been submitted to NIMA
C2 (A2Hz−1) (2.00 ± 0.04) · 10−19
C3 (A3Hz−1) (5.32 ± 0.32) · 10−25
C3,empir (A3Hz−1) (5.19 ± 0.53) · 10−25
Zs. Elter Advanced neutron monitoring 8/10
IntroductionHigher Order Campbelling
Wrap up
Numerical studiesExperimental studiesSmart detector
Self diagnosing detector
I A measurement system which could identify malfunction (theleakage of filling gas)
I pyFC simulations: the pulse shape change due to leakage
I Calibration term changes: underestimation of count rate
I FWHM of the PSD of the signal changes due to the pulseshape change (and not due to the count rate change)
Cn ↓ = 〈xn〉 ↓+∞∫−∞
f (t)ndt ↓
Zs. Elter et al. Physor 2016
Zs. Elter Advanced neutron monitoring 9/10
IntroductionHigher Order Campbelling
Wrap up
Summary and ongoing work
I Lack of overlap between pulse and Campbell mode
I Higher Order Campbell: wider count rate range
I Numerical and experimental verification
I Implementing HOC on FPGA board (G. de Izarra et al. to be submitted (2016))
I PSD FWHM measurement implementation on FPGA
I Uncertainty study of the calibration coefficient (with theFANISP algorithm developed by Z. Perko, TU Delft)
Zs. Elter Advanced neutron monitoring 10/10
Thank you for the attention!
Appendix
IntroductionHigher Order Campbelling
Wrap up
Simulation of the pulse creation - pyFC
Trajectory of heavyions, and electron-ionpair creation
Zs. Elter CTH-NT-318 report (2015)
Current induced bythe electrons
Zs. Elter Advanced neutron monitoring 13/10
IntroductionHigher Order Campbelling
Wrap up
The toolbox/Model discretization
I Discretization works like in a real detector system
I Time resolution set by user (usually 109 1/s)
I The pulse shape is stored on finite memory
I If more pulses occur during one time step the code sums upthem
I Note: the simulations have a statistical error as well (numberof pulses in a given measurement time is Poisson distributed),which has nothing to do with the toolbox
Zs. Elter Advanced neutron monitoring 14/10
IntroductionHigher Order Campbelling
Wrap up
Count rate measurement goals
I What are we looking for? Count rate
I Best methods to estimate the intensity (count rate) of thesignal (which is related to the neutron flux!)
I Linear relation between the Input and the Estimation possiblyon a wide intensity range
Zs. Elter Advanced neutron monitoring 15/10
IntroductionHigher Order Campbelling
Wrap up
Pulse mode vs Campbell mode
Pulse mode
I Counting the pulses (with logicalcircuits)
I Robust, simple method
I Cannot distinguish overlappingpulses (deadtime)
Campbell mode
I Relationship between the varianceof the signal and the intensity (forpulses with random amplitude x)
D2(η) = s0〈x2〉+∞∫−∞
f (t)2dt (2)
Zs. Elter Advanced neutron monitoring 16/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - Pulse width sensitivity5% noise applied
Linearity defect(depending on noise)PM: Pulse modeCM: Campbell mode
Zs. Elter et al. NIMA Vol.774 p60-67 (2015)
I Shorter pulse: better performance (but dedicated filling gas isneeded)
Zs. Elter Advanced neutron monitoring 17/10
IntroductionHigher Order Campbelling
Wrap up
Statistical uncertainty
I The statistical uncertainty originated from the finitemeasurement time
Zs. Elter Advanced neutron monitoring 18/10
IntroductionHigher Order Campbelling
Wrap up
Pulse shape used
I Exponential pulse shape (quick damped pulse)
I Pulse width: when the pulse reaches the 90% of the amplitude
I All defined to have the same charge
I (At this moment deterministic amplitudes)
Zs. Elter Advanced neutron monitoring 19/10
IntroductionHigher Order Campbelling
Wrap up
Theoretical workI The signal is considered as sum of pulses with exponentially
distributed arrival timesI Derivations are based on solving the backwards Master
equation (Pal et al.)
Zs. Elter Advanced neutron monitoring 20/10
IntroductionHigher Order Campbelling
Wrap up
Theoretical work
I The signal is considered as sum of pulses with exponentiallydistributed arrival times
I Derivations are based on solving the backwards Masterequation (Pal et al.)
I The work treated various pulse shapes, and amplitudedistributions
I My contributionI Creating a Mathematica simulation (continuous model, easy to
build)I Checking the results of the derivations
Zs. Elter Advanced neutron monitoring 21/10
IntroductionHigher Order Campbelling
Wrap up
Conclusion of theoretical work (Limitation of Mathematica)
I Reaching an analytical solution is not always possibleI Realistic pulse shapesI Realistic pulse amplitude distributions
I Including any noise is problematic
I Investigating the ”reality” needs computer simulation
I Due to the noise this has to be numerical simulation
I It is possible to include this in Mathematica (down sampling)
I But Mathematica was not created for this: slow
I The following simulations were made in Matlab
Zs. Elter Advanced neutron monitoring 22/10
IntroductionHigher Order Campbelling
Wrap up
Master equation
W (x) =
∫ x
−∞w(x ′) dx ′ = P {ξ ≤ x} (3)
H(y , t) =
∫ +∞
−∞∆[y − ϕ(x , t)]w(x) dx (4)
h(y , t) =
∫ +∞
−∞δ [y − ϕ(x , t)] w(x) dx . (5)
T (t0, t) = exp
{−∫ t
t0
s(t ′) dt ′}. (6)
Zs. Elter Advanced neutron monitoring 23/10
IntroductionHigher Order Campbelling
Wrap up
Master equation
P {η(t) ≤ y |η(t0) = 0} = P(y ,t|0, t0) =
∫ y
−∞p(y ′, t|0, t0) dy ′
(7)
p(y , t|0, t0) = T (t0, t) δ(y) +
∫ t
t0
T (t0, t′)s(t ′)∫ y
−∞h(y ′, t − t ′) p(y − y ′, t|0, t ′) dy ′ dt ′
Zs. Elter Advanced neutron monitoring 24/10
IntroductionHigher Order Campbelling
Wrap up
Theoretical limitations
I Reaching an analytical solution is not always possibleI Realistic pulse shapesI Realistic pulse amplitude distributions
I Including any noise is problematic
I Even simple cases can cause problems (rectangular pulses withdeterministic amplitudes
I The process has onlydiscrete values
Zs. Elter Advanced neutron monitoring 25/10
IntroductionHigher Order Campbelling
Wrap up
Experimental verificationI Experimental verification of the Poisson characteristicI Experiment performed in Minerve reactorI FC + pre-amplifier + oscilloscope
Zs. Elter Advanced neutron monitoring 26/10
IntroductionHigher Order Campbelling
Wrap up
Theoretical verification
I The validity of the implementation was checkedI For this the level crossing intensity was calculated (proposed
by L. Pal et al.)I Intensity of arrival of particles which induce a jump above a
certain level (arbitrary units on the plot)
s0: intensity; T0: pulse widthµ: parameter of the amplitudedistribution
nst(A) = s0
A∫0
pst(y)[1−W (A− y)]dy
(8)pst : Probability distribution function ofthe signalW (A− y): Distribution function of thepulse amplitude (optional)
Zs. Elter Advanced neutron monitoring 27/10
IntroductionHigher Order Campbelling
Wrap up
Theoretical verification 2.
I Exponential pulse shape: f (t) = e−t/p
I Exponentially distributed amplitude with parameter µ
nst(A) = s0(µA)s0p
Γ(s0p + 1)e−µA (9)
s0 = 10−8 s−1
p = 20 nsµ = 0.5 µA−1
Zs. Elter Advanced neutron monitoring 28/10
IntroductionHigher Order Campbelling
Wrap up
Representation of related electronic system
I The toolbox creates the signal such as it appears after thepre-amplifier
I Band-pass filter has no impact on the studied count rate range
I Difference in simulation: post processing is solved with thecomputer as well
Zs. Elter Advanced neutron monitoring 29/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - white noise sensitivity of current methods
PM: Pulse ModeCM: Campbelling Mode
I Pulse mode is relatively insensitive
I Second order Campbelling method is biased by noise at lowintensity levels
Zs. Elter Advanced neutron monitoring 30/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - Amplitude distribution sensitivity of methods
PM: Pulse ModeCM: Campbelling Mode
I Truncated Gaussian amplitude distribution(Var(x) = c2 · 〈x〉2)
I Pulse mode would need additional calibration
Zs. Elter Advanced neutron monitoring 31/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - Pulse width sensitivity
I 5% noise applied
PM: Pulse ModeCM: Campbelling Mode
I Shorter pulse: better performance
Zs. Elter Advanced neutron monitoring 32/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - Pulse vs Campbell conclusionsI Linearity defect depending on noiseI Campbell: high sensitivity to noiseI Pulse: problems with amplitude distributionI Need for some method solving these issues
Zs. Elter Advanced neutron monitoring 33/10
IntroductionHigher Order Campbelling
Wrap up
Overview of the calculations - What is a cumulant?
The κn cumulants of an rv. X are defined via thecumulant-generating function:
g(t) = logE(etX )
g(t) =∞∑n=1
κntn
n!
κ1 is the mean
κ2 is the variance
If X is normally distributed κn = 0 for n ≥ 3
Zs. Elter Advanced neutron monitoring 34/10
IntroductionHigher Order Campbelling
Wrap up
Overview of the calculations - Campbell mode
κn = s0〈xn〉+∞∫−∞
f (t)ndt (10)
I Higher order methods can suppress the impact of noise
I They could suppress the effect of smaller pulses (like gammabackground)
I In measurement calibration is needed (in simulation the inputsare ”known”)
Zs. Elter Advanced neutron monitoring 35/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC methods
I Without noise (Tmeasurement = 10−2 s)
Zs. Elter Advanced neutron monitoring 36/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC methods - inaccuracy?
Unbiased estimator:〈kn〉 = κnvar(kn) ∝ κn2 ⇒ Large n requires longermeasurement
At higher count ratesthe variance (and othercumulants) are higher,thus the estimation ofthe cumulants is lessaccurate
Zs. Elter Advanced neutron monitoring 37/10
IntroductionHigher Order Campbelling
Wrap up
Convergence of the cumulants (theory)
Zs. Elter Advanced neutron monitoring 38/10
IntroductionHigher Order Campbelling
Wrap up
Biased and unbiased estimators
κn = µn −n−1∑i=1
(n−1i
)κn−1µi
Where µn can be estimated as µn = SnN =
N∑jX nj
N
This leads to a so called biased estimator.X is the random variable, N samples.
Zs. Elter Advanced neutron monitoring 39/10
IntroductionHigher Order Campbelling
Wrap up
Biased and unbiased estimators 2.
Unbiased estimators can be found for examplehttp://mathworld.wolfram.com/k-Statistic.html
k3 =2S3
1−3NS1S2+N2S3
N(N−1)(N−2)
This is the unbiased estimator of the third cumulant.I showed that in our studies the unbiased and the biased estimatorslead to the same result (N is really high).
Zs. Elter Advanced neutron monitoring 40/10
IntroductionHigher Order Campbelling
Wrap up
Calculation time for biased and unbiased estimators
Zs. Elter Advanced neutron monitoring 41/10
IntroductionHigher Order Campbelling
Wrap up
Reliability of calculation time
I We have to be sure that calculating the cumulant is notlonger than the measurement time
I We compared C++ with Matlab (same pulse train was used)
Used language Calculation Time
Matlab (unbiased k3, Tmeas = 10−2 s) 0.78 sC++ (unbiased k3, Tmeas = 10−2 s) 5 ms
Zs. Elter Advanced neutron monitoring 42/10
IntroductionHigher Order Campbelling
Wrap up
Variance of the cumulant estimator
Zs. Elter Advanced neutron monitoring 43/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC methods: noise sensitivity
I The higher order methods can suppress noise
Zs. Elter Advanced neutron monitoring 44/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC methods shot noise sensitivity 1.
I Background radiation can trigger pulses
I For example: gamma radiation
I Also creates a Poisson Pulse train
I Possibly smaller amplitudes
I Simple model: same pulse shape, proportional parametersIntensity: sγ = αsnAmplitude: aγ = βan
I What is the caused error of Campbelling?Which background can be suppressed?
Zs. Elter Advanced neutron monitoring 45/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC methods shot noise sensitivity 2.
sγ = αsn & aγ = βan (α, β ∈ [0,1])
2nd order 3rd order 4th order
Zs. Elter Advanced neutron monitoring 46/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC: inhomogeneous process (transient) 1.
The intensity is a time dependent parameter: s0(t)
Homogeneous Inhomogeneous
Zs. Elter Advanced neutron monitoring 47/10
IntroductionHigher Order Campbelling
Wrap up
Preliminary calculations - HOC: transient 2. (count rate)
Zs. Elter Advanced neutron monitoring 48/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC: transient 3. (moving cumulant)
Zs. Elter Advanced neutron monitoring 49/10
IntroductionHigher Order Campbelling
Wrap up
Calculations - HOC: transient 4. (result)
Zs. Elter Advanced neutron monitoring 50/10
IntroductionHigher Order Campbelling
Wrap up
Conclusion of HOCI Due to convergence only up to 4th orderI Filters noise regardless the frequencyI Suppress small pulses (but it is already solved with 2nd order)I Article draft is ready for ”iteration”, to be submitted ASAP
Zs. Elter Advanced neutron monitoring 51/10
IntroductionHigher Order Campbelling
Wrap up
Gamma sensitivity of HOC in Astrid-like reactorI Astrid-like neutron and gamma flux, reaction rate from
TRIPOLI (V. Verma)I Gamma pulses in CFHT from Chester (P. Filliatre)I Gamma sensitivity of HOC mode from the toolbox (Zs. Elter)I Note to be written and to be submitted ASAP
Zs. Elter Advanced neutron monitoring 52/10
IntroductionHigher Order Campbelling
Wrap up
Experimental work conclusions (+Chester simulation)
I The applicability and linearity of HOC methods are verified X
I The measurements provide an opportunity to validate Chester(CFUL01 has 4 fissile layers)
I Article is under progress
Zs. Elter Advanced neutron monitoring 53/10