Advanced Validation Strategy for Nabrawind Self Erected Tower
![Page 2: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/2.jpg)
NABRAWINDAdvanced Wind Technologies
1 Introduction
Drastic Cost Reduction
Modularity Proven Technologies
Modular Blade Joint
Self Erected Tower
Nabrawind Introduction
![Page 3: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/3.jpg)
1 Introduction
Cost Increase€HH140=1.6·€HH100
Most Expensive Component HH>120
LogisticsRoads / Bridges Limiting Concepts
Assembly CranesLack of AvailabilityLarge Mobilization and Rental Costs
Installation RateNew Concepts Delaying Wind Farm Installation Rates
WTG IntegrationControl Challenges in Soft-Soft TowersSoft-Stiff Unfeasible for XXL Steel Towers
XXL Tower Challenges
![Page 4: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/4.jpg)
2 XXL Tower Alternatives Evaluation
TubularSteel
SegmentedSteel
PrecastConcrete or
HybridLattice Nabrawind
SET
Tower Cost
Logistics
Assembly & Erection
Modal Coupling
Operation Proven Life
Good Poor
![Page 5: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/5.jpg)
Nabrawind SET
3 Nabrawind Self Erected TowerAdvanced Lattice Structure
Client WTG
Client WTG
![Page 6: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/6.jpg)
Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly
3 Nabrawind Self Erected TowerAdvanced Lattice Structure
80 100 120 140 160 180
Tota
l Cos
t [k€
]
Hub Height [m]
Tower + Installation Cost
Steel Tubular
Hybrid Tubular
NBW -30%+40m
![Page 7: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/7.jpg)
3 Nabrawind Self Erected TowerAdvanced Lattice Structure
Self ErectionNo Large Cranes
Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly
![Page 8: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/8.jpg)
3 Nabrawind Self Erected TowerAdvanced Lattice Structure
Self ErectionNo Large Cranes
Fast Assembly2-Days WTG Erection (Wind >15m/s)Prefab Foundation (T<0ºC)
0 5 10 15
SET160m
Concrete140m
Steel100m
Steel60m
Installation Days
Crane Inst
WTG Inst.
Crane Des
WTG Installation Sequence (no Foundation)
0 10 20 30 40 50 60
SET160m
Concrete140m
Steel100m
Steel60m
Installation Days
FoundationFound. CuringCrane InstWTG Inst.Crane Des
WTG Installation Sequence
Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly
![Page 9: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/9.jpg)
3 Nabrawind Self Erected TowerAdvanced Lattice Structure
Self ErectionNo Large Cranes
Fast Assembly2-Days WTG ErectionPrefab Foundation
Easy WTG IntegrationSoft-Stiff Tower H>180No Functional Affection
Freq
uenc
y [H
z]
Rotor speed [rpm]
1P
3P
6P
1st Bending
2nd Bending
1st Torsion
⍉130 HH160 Campbell Diagram
Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly
![Page 10: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/10.jpg)
3 Nabrawind Self Erected TowerAdvanced Lattice Structure
Simple Logistics and OperationPackable in Standard 40ft ContainersMaintenance Free Structure and Connections
Self ErectionNo Large Cranes
Fast Assembly2-Days WTG ErectionPrefab Foundation
Easy WTG IntegrationSoft-Stiff Tower H>180No Functional Affection
Ultra Low CostFoundation / Tower ComponentsLogistics / Assembly
![Page 11: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/11.jpg)
TubularSteel
SegmentedSteel
PrecastConcrete or
HybridLattice Nabrawind
SET
Tower Cost
Logistics
Assembly & Erection
Modal Coupling
Operation Proven Life
Nabrawind Self Erected TowerTower Alternatives Comparison3
![Page 12: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/12.jpg)
4 CENER Introduction21 M€ In 2016 the annual budget is
20,5€ million. 70% self-financing
190 190 employees
100 M€ Total investments (2002-2016): ~ 101€ million
NUMBERS:• Wind Power• Photovoltaic• Solar thermal• Biomas• Grid integration• Bioclimatic architecture
AREAS
![Page 13: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/13.jpg)
5 Advanced Tower Validation WTG Blades vs Towers Validation Strategy Comparison
FullScaleTests
SubcomponentTests
Coupon Tests
WTG Blades
Component Verification √
Design Details
Validation√
Material Allowables Definition
√
![Page 14: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/14.jpg)
5 Advanced Tower Validation WTG Blades vs Towers Validation Strategy Comparison
FullScaleTests
SubcomponentTests
Coupon Tests
WTG Blades
WTGTowers SET
Component Verification √ X √
Design Details
Validation√ ∼ √
Material Allowables Definition
√ ∼ √
![Page 15: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/15.jpg)
6 Fatigue Full Scale Tower TestTest Objectives
Tower & Foundation Accelerated Proven Life
0
5
10
15
20
25
0 5 10 15 20
Ope
rativ
e Pr
oven
Life
[yea
rs]
Time [years]
Accelerated Test
Operational Proven Life Acceleration
Conventional Operation
![Page 16: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/16.jpg)
6 Fatigue Full Scale Tower TestTest Setup
Hot SpotsLattice Members
Foundation SettlementBolt Preload Control
Tower Head MassTower Head Exciter
Strain GaugesLVDTLVDT
Bolt Load Sensors
![Page 17: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/17.jpg)
6 Fatigue Full Scale Tower TestTest Design
Tow
er H
eigh
[m]
Bending Moment Ranges [kNm]
20y Design Loads20y Eq. Test LoadsFinal Test Loads
γt
Full Scale Test Load Distribution
Tower DesignFatigue Loads20/25 years
Test EquivalentLoads
>20/25 years
Test Loads
Damage-Equivalent Ranges Analysis
IEC61400-23 based Test Factor (γt):- Conseq. Failure- Tower Variation- Fatigue Formulation
![Page 18: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/18.jpg)
7 XXL Tower Alternatives EvaluationAfter SET Full-Scale Test
TubularSteel
SegmentedSteel
PrecastConcrete or
HybridLattice Nabrawind
SET
Tower Cost
Logistics
Assembly & Erection
Modal Coupling
Operation Proven Life
![Page 19: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/19.jpg)
Tower Tests
8 Nabrawind Self Erected Tower ProjectProject Summary
Design Certificate
2015 2016
Company / Project Funding
SET TechnologyDevelopment
HH160 Tower Detailed Design
2017 2018
HH160 Tower Prototype Manuf. & Erection
Tower Certificate
TowerPreserials
![Page 20: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/20.jpg)
8 Nabrawind Self Erected Tower ProjectProject Summary
![Page 21: Advanced Validation Strategy for Nabrawind Self Erected Tower · Control Challenges in Soft-Soft Towers Soft-Stiff Unfeasible for XXL Steel Towers XXL Tower Challenges. 2 XXL Tower](https://reader036.vdocument.in/reader036/viewer/2022071111/5fe604aa6e80175ae964fec2/html5/thumbnails/21.jpg)
Thanks for your Attention