SUPERIOR PERFORMANCE And Quality In Blast Cleaning Equipment Ph: (780) 425-5510 Fax: (780) 425-5540 ! WARNING Manual # AC1708 Read Manual Copyright© 2017 Mod-U-Blast®, All Rights Reserved Failure to read, understand & follow all safety and operation procedures in this manual can cause injury or death. Manuals that are lost, incomplete, or damaged, must be replaced immediately.

Upload: others

Post on 22-Aug-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Aftercooler Owner’s Manual...Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers

Aftercooler Owner’s Manual

SUPERIOR PERFORMANCE And Quality In Blast Cleaning Equipment

Ph: (780) 425-5510 Fax: (780) 425-5540

! WARNING

Manual # AC1708

Read Manual

Copyright© 2017 Mod-U-Blast®, All Rights Reserved

Failure to read, understand & follow all safety and operation procedures in this manual can cause injury or death. Manuals

that are lost, incomplete, or damaged, must be replaced

immediately.

Page 2: Aftercooler Owner’s Manual...Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers

Aftercooler Owner’s Manual

2 Copyright© 2017 Mod-U-Blast®, All Rights Reserved

Dry-Pro Skid Mounted Moisture Removal Package

Parts Ordering: 1-800-661-3842

www.modublast.com

IMPORTANT WARNINGS

OPERATION

Warning: DO NOT OPERATE THIS EQUIPMENT OVER 200 PSI

Danger: DO NOT ATTEMPT TO REMOVE OR REPAIR ANY PART OF THE SYSTEM UNITIL IT IS COMPLETELY DEPRESURIZED. SERIOUS PERSONAL INJURY OR DEATH MAY RESULT IF THIS RULE IS NOT FOLLOWED

1. Connect an air hose from the air supply to the inlet side of the aftercooler.

2. Connect an air hose from the aftercooler skid outlet to the equipment air inlet.

3. Start the compressor.

4. Slowly open the air inlet ball valve to pressurize the system.

5. Adjust the regulator for the air motor on the Filter-Regulator-Lubricator (FRL) (Instructions next page) to read the working pressure (PSI) on the label. NOTE: On hot days run the air motor at maximum pressure. (see chart next page)

6. Adjust the oil output on the lubricator (Clear Dial) by turning clockwise or counter clock-wise until there is the required drops of oil every minute. (see chart next page)

7. Open the air supply to the equipment. (if ball valve is equipped)

8. Slightly open the ball valve for the moisture separator (black canister) and let it drain while using the unit.

NOTE: COLD WEATHER OPERATION - The fan air motor should be regulated so that the aftercooler temperature gauge reads above 0°C to avoid freezing the core assembly. The aftercooler has a drain installed for cold weather climate areas and should be drained after every use to avoid core damage. Leave the aftercooler drain open when not in use.

Page 3: Aftercooler Owner’s Manual...Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers

Pressure & CFM Requirements for Aftercooler Air Motors

NOTE: Working pressure is at 21°C (70°F) ambient temperature. In warmer weather the air motors can be operated up to or at the maximum pressure.

3 Copyright© 2017 Mod-U-Blast®, All Rights Reserved

Aftercooler Owner’s Manual

SHUT DOWN

Filter Do Not Fill

With Oil

Regulator Pull down on knob to adjust

Push up to lock

Lubricator Fill to Line on Glass With ATF

FRL

1. Close the ball valve on the outlet side of the aftercooler package or at the equipment. (if equipped)

2. Shut down the air supply to the aftercooler package.3. Open the drains for the aftercooler, coalescer and moisture separator.4. After the air is removed, close the air inlet ball valve.5. Leave all the drains open while storing.

Page 4: Aftercooler Owner’s Manual...Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers

Aftercooler Owner’s Manual

4 Copyright© 2017 Mod-U-Blast®, All Rights Reserved

FRL

DIFFERENTIAL PRESSURE GAUGE

AFTERCOOLER

AIR INLET

AIR OUTLET

THERMOMETER

MOISTURE FILTER

COALESCER DRAINS

DSA-250MS-M Shown here

Page 5: Aftercooler Owner’s Manual...Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers

5 Copyright© 2017 Mod-U-Blast®, All Rights Reserved

Aftercooler Owner’s Manual

For Parts Call 1-800-661-3842 and Ask For The Order Desk

Thermometer 20114 1 1 1 1 1

FRL Pressure Gauge 55415 1 1 1 1 1

Air Motor for Aftercooler DAC-AMV4 1 1 1

Air Motor for Aftercooler DAC-AM6 1

Air Motor for Aftercooler DAC-AM16 1

Aftercooler (w/o air motor) DAC-250 1

Aftercooler (w/o air motor) DAC-450 1

Aftercooler (w/o air motor) DAC-750 1

Aftercooler (w/o air motor) DAC-1000 1

Aftercooler (w/o air motor) DAC-1600 1

Coalescer Replacement Element - MUB* DSC-250-DEL 1

Coalescer Replacement Element - MUB* DSC-450-DEL 1

Coalescer Replacement Element - MUB* DSC-750-DEL 1

Coalescer Replacement Element - MUB* DSC-1000-DEL 1

Coalescer Replacement Element - MUB* DSC-1600-DEL 1

Coalescer Differential Pressure Gauge - MUB* DSC-DPG 1 1 1 1 1

Description Stock # DSA250MS-M DSA450MS-M DSA750MS-M DSA1000MS-M DSA1600MS-M QTY QTY QTY QTY QTY

PARTS LIST

Note: These skid units may have been substituted with AKG aftercoolers which will be la-beled. Our regular MUB coalescers are RED in colour all others would be gold or white.Please check the unit to see what is installed before ordering. All units with AKG aftercoolers and non MUB coalescers please contact your Mod-U-Blast sales representative for price and availability.

*MUB - Mod-U-Blast Model (Red)

Page 6: Aftercooler Owner’s Manual...Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers

Aftercooler Owner’s Manual

6 Copyright© 2017 Mod-U-Blast®, All Rights Reserved

Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers the equipment as well as all major components.

This warranty does not apply to abnormal use of the equipment or parts. Parts considered consumables are not

covered by warranty.

Claims will be honored only if the warranty card is returned within a period of two (2) months from the factory shipping date.

The card can be returned to your Mod-U-Blast salesperson or mailed to the address below.

In the event of failure of this equipment please contact a Mod-U-Blast service centre

or call (780) 425-5510.

403 - 69 Avenue NWEdmonton, Alberta

CanadaT6P 0C2

PH: (780) 425-5510 FAX: (780) 425-5540