emdsrn.book Page 1 Friday, December 8, 2006 1:17 PM
Agilent 85270 Electromagnetic Design System
Release Notes
Agilent Technologies
EMDS Release Notes
Notices© Agilent Technologies, Inc. 2006
No part of this manual may be reproduced in any form or by any means (including elec-tronic storage and retrieval or translation into a foreign language) without prior agree-ment and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws.
Manual Part NumberOnline-only document.
EditionDecember 2006
Printed in USA
Agilent Technologies, Inc.3501 Stevens Creek Blvd. Santa Clara, CA 95052 USA
Warranty
The material contained in this docu-ment is provided “as is,” and is sub-ject to being changed, without notice, in future editions. Further, to the max-imum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a par-ticular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connec-tion with the furnishing, use, or per-formance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the sep-arate agreement shall control.
Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accor-dance with the terms of such license.
Restricted Rights LegendU.S. Government Restricted Rights. Soft-ware and technical data rights granted to the federal government include only those rights customarily provided to end user cus-tomers. Agilent provides this customary commercial license in Software and techni-cal data pursuant to FAR 12.211 (Technical Data) and 12.212 (Computer Software) and, for the Department of Defense, DFARS 252.227-7015 (Technical Data - Commercial Items) and DFARS 227.7202-3 (Rights in Commercial Computer Software or Com-puter Software Documentation).
Safety Notices
CAUTION
A CAUTION notice denotes a haz-ard. It calls attention to an operat-ing procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
WARNING
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly per-formed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated condi-tions are fully understood and met.
Microsoft ® is a U.S. registered trademark of Microsoft Corporation.
Windows ® and Microsoft Windows ® are U.S. registered trademarks of Microsoft Corporation.
Adobe ® and Acrobat ® are trademarks of Adobe Systems Incorporated.
Autodesk ® and AutoCAD ® are trademaks of Autodesk, Incorporated.
Software RevisionThis guide is valid for A.01.xx revisions of the Agilent 85270 Electromagnetic Design System software, where xx refers to minor revisions of the software that do not affect the technical accuracy of this guide.
emdsrn.book Page 2 Friday, December 8, 2006 1:17 PM
emdsrn.book Page 3 Friday, December 8, 2006 1:17 PM
Contents
1 Product Features 5
Project Management Features 6
Drawing Features 7
Simulation Features 8
Post Processor Features 9
Documentation Features 10
Enhancements 11
2 Known Problems and Workarounds 13
Operating Environment 14
Incorrect Display of Dialog Boxes 14Installation Errors 14Opening Projects from Agilent Legacy 3D EM Products 16
Drawing Environment 17
Cancelling Commands 17Layer Numbers Limitted for ADS Import 17
Simulation 18
Low Frequency Accuracy 18Circuit Sources and Symmetry Planes 18
Post Processor 19
Running Out of Memory 19
Index 21
EMDS Release Notes 3
Contents
emdsrn.book Page 4 Friday, December 8, 2006 1:17 PM
4 EMDS Release Notes
Agilent 85270 Electromagnetic Design SystemRelease Notes
emdsrn.book Page 5 Friday, December 8, 2006 1:17 PM
1Product Features
Drawing Features 7
Simulation Features 8
Post Processor Features 9
Documentation Features 10
Enhancements 11
This section describes some of the features and future enhancements of Electromagnetic Design System 2006C (EMDS).
Agilent EMDS models the electromagnetic behavior of passive structures. You can use EMDS to analyze structure geometry and material specifications.
Agilent EMDS computes:
• S- parameters for multiple modes
• Electric field distributions, including far- field antenna radiation patterns
• Impedance and propagation constants for multiple modes
5Agilent Technologies
1 Product Features
emdsrn.book Page 6 Friday, December 8, 2006 1:17 PM
Project Management Features
Project management tools in EMDS enable you to:
• Browse project directories
• View individual project information
• Preview a project drawing
• Create new projects
• Open the last project used
• Open example projects
• Copy or rename a project
• Delete a project
• Save projects
6 EMDS Release Notes
Product Features 1
emdsrn.book Page 7 Friday, December 8, 2006 1:17 PM
Drawing Features
Drawing features included in EMDS enable you to:
• Work with 2D or 3D objects
• Use objects from the EMDS Object Library
• Edit individual objects
• Change option attributes such as:
• View or Hide Objects
• Rename Objects
• Change Object Colors
• Setup Object Simulation Options
• Define line and plane options such as:
• Line Define or Delete
• Plane Define, Offset, Delete or Set
• Change window options such as:
• Panning an object
• Changing the shading of an object
• Set Project and System Preferences
• Zoom objects
• Change the Viewing Direction of an Object
EMDS Release Notes 7
1 Product Features
emdsrn.book Page 8 Friday, December 8, 2006 1:17 PM
Simulation Features
Simulation features in EMDS enable you to:
• Quickly setup solve options
• Run and control your simulation
• View log files and status information
8 EMDS Release Notes
Product Features 1
emdsrn.book Page 9 Friday, December 8, 2006 1:17 PM
Post Processor Features
Post Processor features are included in EMDS enable you to:
• Launch and setup the post processor
• Plot S- parameter and field plots
• Plot Far Field Plots and Antenna Parameters
• View and Edit an Electronic Notebook
EMDS Release Notes 9
1 Product Features
emdsrn.book Page 10 Friday, December 8, 2006 1:17 PM
Documentation Features
EMDS product documentation is provided in both Microsoft® Windows® Help format and Adobe® Portable Document Format (PDF).
• Windows Help format can be easily accessed directly from EMDS by choosing Help > Help. Standard Windows Help features such as Contents, Index, Search and Favorites are available.
• Adobe PDF format is available under your installation directory in the following location:
<installation folder>/doc/pdf
If you want to print a hardcopy of your documentation, PDF files are highly recommended for best print quality.
10 EMDS Release Notes
Product Features 1
emdsrn.book Page 11 Friday, December 8, 2006 1:17 PM
Enhancements
Electromagnetic Design System 2006C is a standalone product. With 2006C, Agilent EEsof EDA provides a basic level of integration with Advanced Design System (ADS) with an advancement of integration levels provided in future releases.
In future releases of EMDS, you should expect features such as:
• Parameter Sweep
• Optimization
• Integration with GENESYS
• Import of Solid Models
• Remote Simulation (PC to PC and PC to Linux)
EMDS Release Notes 11
1 Product Features
emdsrn.book Page 12 Friday, December 8, 2006 1:17 PM
12 EMDS Release Notes
Agilent 85270 Electromagnetic Design SystemRelease Notes
emdsrn.book Page 13 Friday, December 8, 2006 1:17 PM
2Known Problems and Workarounds
Operating Environment 14
Drawing Environment 17
Simulation 18
Post Processor 19
This chapter lists potential problems that may be encountered when running Electromagnetic Design System (EMDS), and workarounds where applicable.
13Agilent Technologies
2 Known Problems and Workarounds
emdsrn.book Page 14 Friday, December 8, 2006 1:17 PM
Operating Environment
The following problems related to operating environments have been identified.
Incorrect Display of Dialog Boxes
On systems using the Microsoft® Windows® environment, you cannot have your display desktop area set to 800x600 pixels and use large fonts. With this configuration, some Agilent EMDS dialog boxes are too large to display correctly and the application may close. You can use 800x600 with small fonts.
To see the Display settings on Windows 2000®, choose Start > Settings > Control Panel > Display > Settings.
Installation Errors
Microsoft .NET Framework Error
You may encounter an installation error with the message
1603: Error installing Microsoft(R) .NET Framework.
This can be seen if a recent .NET Framework security update has been installed prior to installing EMDS. Specifically, this behavior occurs if security update MS05- 004 was installed prior to installing EMDS.
You will need to remove the .NET Framework security update. To remove the update:
1 Open Add/Remove Programs in the Control Panel.
2 Open Add or Remove Programs. Be sure that Show Updates is selected.
3 Select Microsoft .NET Framework Hotfix 1.0 (KB886906) or Microsoft .NET Framework Hotfix 1.1 (KB886904) and click Remove.
14 EMDS Release Notes
Known Problems and Workarounds 2
emdsrn.book Page 15 Friday, December 8, 2006 1:17 PM
4 After removing the security update, re- install EMDS.
5 After installing EMDS, it is recommended that you re- install the .NET Framework security updates.
Microsoft has published the KB article 899619 (http://support.microsoft.com/default.aspx?scid=kb;en- us;899619) that describes the behavior and provides a solution.
Self-Extraction Error
After the self- extraction process has completed, if you receive the following error,
This installation package could not be opened. Verify that the package exists and that you can access it, or contact the application vendor to verify that this is a valid Windows Installer package.
This installation package could not be opened. Contact the application vendor to verify that this is a valid Windows Installer package
you will need to follow the procedure below to extract and run the installation package manually.
1 Save the installation package in a temporary location. Ensure that the directory you choose does not include other setup executables that may be confused with the EMDS executable.
2 Extract the file using WinZip® or an equivalent file utility.
3 Double- click the extracted setup.exe file to launch the installation wizard.
EMDS Release Notes 15
2 Known Problems and Workarounds
emdsrn.book Page 16 Friday, December 8, 2006 1:17 PM
Opening Projects from Agilent Legacy 3D EM Products
Projects constructed using the Agilent 85180 legacy product can be opened in EMDS. However, be aware that:
• Once brought into EMDS, projects cannot be read back into the Agilent 85180 legacy product. You may want to make a copy of your projects before reading them into EMDS.
• Impedance, Calibration, and Polarization lines will need to be reconstructed for any Agilent 85180 project read into EMDS.
16 EMDS Release Notes
Known Problems and Workarounds 2
emdsrn.book Page 17 Friday, December 8, 2006 1:17 PM
Drawing Environment
The following problems have been identified in the Agilent EMDS drawing environment.
Cancelling Commands
To cancel a command from the drawing environment, press the ESC key.
Layer Numbers Limitted for ADS Import
It is possible to define layers in ADS with arbitraty layer numbers; however, only the layer numbers 0- 256 are supported for the ADS to EMDS translation. If your ADS layout contains layer numbers greater than 256, you will need to reset these layer numbers before executing Momentum > 3D EM > Save files for 3D EM.
EMDS Release Notes 17
2 Known Problems and Workarounds
emdsrn.book Page 18 Friday, December 8, 2006 1:17 PM
Simulation
The following problems have been identified in the Agilent EMDS simulators.
Low Frequency Accuracy
Agilent EMDS encounters stability problems when attempting to solve at low frequencies. While there are no distinct frequency limits, use the following guidelines:
• Structures with higher value dielectrics have a higher low- frequency limit.
• Small structures have a higher low- frequency limit.
• Structures with smaller features have a higher low- frequency limit.
Circuit Sources and Symmetry Planes
In Agilent EMDS, the proper scale factors are automatically determined, but will only be correct under the following conditions:
• Symmetric E Plane and Symmetric H Plane boundary conditions (not Perfect E and Perfect H) are used to define the symmetry planes.
• All symmetry planes are mutually orthogonal.
• The circuit sources are properly defined with respect to the symmetry planes:
• Circuit sources should lie completely in Symmetric H Plane boundaries.
• Circuit sources should touch, and be normal to, Symmetric E Plane boundaries.
18 EMDS Release Notes
Known Problems and Workarounds 2
emdsrn.book Page 19 Friday, December 8, 2006 1:17 PM
Post Processor
The following problem has been identified in the Post Processor.
Running Out of Memory
The Post Processor does not terminate when the system runs out of memory. If this should happen, stop the application. Use the Task Manager to cancel the application emds_express.exe.
EMDS Release Notes 19
2 Known Problems and Workarounds
emdsrn.book Page 20 Friday, December 8, 2006 1:17 PM
20 EMDS Release Notes
emdsrn.book Page 21 Friday, December 8, 2006 1:17 PM
Index
Aaccuracy
low frequency, 18Advanced Design System, 11
Ccancel command, 17circuit sources, 18
Ddisplay, 14documentation, 10drawing environment, 7, 17
Eenhancements, 11errors
installation, 14
Ffeatures, 5
GGENESYS, 11
Iinstallation
errors, 14
Kknown problems, 13
Llayers, 17
Mmemory, 19
Ooptimization, 11
Pparameter sweep, 11post processor, 9, 19project management, 6
Rremote simulation, 11
SSAT files, 11scale factors, 18simulation, 8, 18
EMDS Release Notes 21
Index