ahu usa catalogue 01-2012 eng - vents usvents-us.com/images/cat/467_256_cat_file.pdf · the...
TRANSCRIPT
2 VENTS. Air handling units | 04-2014
Contents
How to choose Recovery Ventilation type? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
How do HRV, ERV and TRV Systems work?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Types of installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Centralized Recovery Ventilators
VUT 200 H mini. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Brig HRV 120, 170 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Brig HRV 200, 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Frigate HRV 60S, ERV 60S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Frigate HRV 120S, ERV 120S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Frigate HRV 100DS, ERV 100DS, TRV 100DS, HRV 150DS, ERV 150DS, TRV 150DS. . . . .16
Decentralised Recovery Ventilators
TwinFresh S-60, S-60-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
TwinFresh R-50, R-50-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
MICRA 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Optional remote controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Quick Selection Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
3
VentsUS.com
VENTS. Air handling units | 04-2014
Select the ventilator model
If your home is up to:
Area of house Sq. Ft.
HRV ERV TRV
1200 60S 60S
2000 100DS 100DS 100DS
2400 VUT 200 mini, 120, 120S
120S
3000 150S 150S 150DS
3400 170
4000 200
6000 300
HRV (Heat Recovery Ventilation)IIf you use a heating system more often than air conditioning, you need an HRV. Heat recovery systems have been designed to recover the heat contained in the extract air.
ERV (Energy Recovery Ventilation)If you use air conditioning more often than heating, an ERV is recom-mended. The enthalpic core of the ERV transfers heat and moisture from the intake air to the extract air. The air brought into the living area is cooled and the humidity is reduced for maximum comfort. The load on your air conditioner drops and you save on cooling costs.
TRV (Twin Recovery Ventilation)TRV has the benefits of both HRV and ERV. You save heating in winter and air condi-tioning costs in summer. Moreover, you enjoy air with balanced humidity for maximum comfort.
Heat energy
Latent energy(humidity)
Select the correct Recovery Ventilation type
What is the difference?
HR
V Heat transferFrostproof core
Energy efficient rate ERV Heat transfer
Humidity transferOver dry and moisture damage prevention
More energy efficient rate vs. HRV
TRV Heat transfer Humidity transfer
Over dry and moisture damage preventionFrostproof core
Most energy efficient rate vs. HRV&ERVAluminum or plastic core Enthalpic core Aluminum & Enthalpic coreFits to cold climate area Fits to hot and humid climate areas Fits to all climate areas
Improve indoor air quality • Provide fresh air Pre-heat intake air in winter time • Pre-cool intake air in summer time
Save on heating & air conditioning costs Washable filters • Deliver fresh outdoor air
Drives out harmful indoor pollutants
4 VENTS. Air handling units | 04-2014
HRV (Heat Recovery Ventilation)
The fresh incoming air absorbs the heat from the air being extracted. This fresh warm air is then circulated back into the home or building.
ERV (Energy Recovery Ventilation)
In the winter months the core captures the humidity of the extract air and cir-culates it back into the home or build-ing. In summer the humidity is captured and exhausted outside. No drain pan is required.
TRV (Twin Recovery Ventilation)
Heat Energy Recovery Heat EnergyHumidity
Return Humidity
Dust, CO2 and other pollutants
Static Plate (Paper)
Drain Pan is not needed!
Exhaust Air Outside Air
Static Plate (Plastic or metal)
Drain Pan
Exhaust Air Outside Air
Heat Energy Recovery Heat EnergyHumidity
Dust, CO2 and other pollutants
Condensed Moisture
Extract air
Supply air
Exhaust air
Intake air
Extract air
Supply air
Exhaust air
Intake air
Extract air
Supply air
Exhaust air
Intake air
How do HRV, ERV and TRV Systems work?
Contains both HRV and ERV recovery
cores inside.
Both HRV and ERV cores of the Twin Recovery Ventilators provide "sensible" heat transfer. The HRV core makes Twin Recovery Ventilators suitable for cold climate zones and the ERV core increas-es the unit’s efficiency by extra moisture transfer.
5
VentsUS.com
VENTS. Air handling units | 04-2014
Independent System installation
In this application the ductworks are used to supply fresh air to bedrooms and living areas and extract stale air from the bathroom, kitchen and laundry room.
Types of installation
Exhaust and supply combined
Exhaust at the source and supply in the return
This application uses a separate duct system to extract air from the bathroom, kitchen and laundry room.
The fresh air is dumped into the return air duct of the forced air system and is distributed in the house together with supply air.
6 VENTS. Air handling units | 04-2014
Extract air
Supply air
Exhaust air
Intake air
Casing
Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
Filter
Washable G4 air filters in exhaust and supply air streams.
Heat recovery core
Specially designed aluminum plate core ensures excellent heat recovery ef-ficiency. Whenever heat recovery is not required, the heat recovery block can be easily replaced by a "summer" block. The ventilator is also equipped with a drain pan for condensate drainage.
Defrost system
To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions.
Motors
German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in Thermal Overheating Protection with Automatic Restart makes the motor operation se-cure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation.
Fans
The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes.
Control
The ventilator comes with a thyristor speed control.
Mounting
The unit can be mounted in most positions and in most spaces. Please refer to instal-lation manual for instructions and details.
Warranty
5 year warranty
C e n t r a l i z e d R e c o v e r y V e n t i l a t o r s
VUT 200 H mini A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of contaminated air. The HRV ventilators utilize the sensible energy in the heat recovery core. The special polymer core transfers heat from the extract air stream to the intake air stream so you save on energy costs.
Features
Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compact size Defrost system
7
VentsUS.com
VENTS. Air handling units | 04-2014
235/8”
1015/16”
1513/16ӯ 4"
Dimensions
0
50
100
150
200
250
300
0 10 20 30 40 50 60 70
0.0
0.2
0.4
0.6
0.8
1.0
1.2
0 20 40 60 80 100 120 140 160 St
atic
Pre
ssur
e [P
a]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
VUT 200 mini
Performance
Model Volts Max. Watts
Max. Amps RPM
Airflow CFM Heat re-covery core efficiency,
%
Duct Dia.0" 0,125" 0,25" 0,5" 0,75" 1.0" 1.25" 1.5"
VUT 200 H mini
120V, 60Hz 207 1.8 3040 125 123 119 106 89 69 44 14 < 80% 4''
Accessories
g units | 0404 2012 44
Backdraft Dampers Clamps
Air disk valve
Extract air
Supply air
Exhaust air
Intake air
8 VENTS. Air handling units | 04-2014
Casing
Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
Filter
Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease filter.
Heat recovery core
Specially designed polymer plate core ensures excellent heat recovery efficiency. Whenever heat recovery is not required, the heat recovery block can be easily replaced by a "summer" block. The ventilator is also equipped with a drain pan for condensate drainage.
Defrost system
To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions.
Motors
German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation.
Fans
The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes.
Control
The ventilator is equipped with 3-step switch on it's side panel to choose STANDBY, LOW or MEDIUM mode for continuous operation.
The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand.
Mounting
The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details.
Warranty
5 year warranty
Brig HRV 120, 170 A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
Features
Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compact size Defrost system
9
VentsUS.com
VENTS. Air handling units | 04-2014
Ø 6"
25 9/16 "
19 3/4 "
19 11/16 "
9 3/4 "
Dimensions
0
50
100
150
200
250
300
350
0 10 20 30 40 50 60 70 80 90
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0 40 80 120 160 200
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 170
0
50
100
150
200
250
0 10 20 30 40 50 60 70 80 90
0.0
0.2
0.4
0.6
0.8
1.0
0 40 80 120 160 200
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 120
128
131
134
Wat
ts
HRV 120 193
198
203
208
Wat
ts
HRV 170
Performance
Model Volts Max. Watts
Max. Amps RPM
Airflow CFM (L/s) Heat re-covery core efficiency,
%
Duct Dia.0,1"
(25Pa)0,2"
(50Pa)0,3"
(75Pa)0,4"
(100Pa)0,5"
(125Pa)0,6"
(150Pa)0,7"
(175Pa)0,8"
(200Pa)0,9"
(225Pa)1,0"
(250Pa)1,2"
(300Pa)1,4"
(350Pa)
HRV 120 120V, 60Hz 135 1.1 2590 177
(84)160(76)
147(69)
131(62)
118(56)
105(50)
92(43)
77(36)
62(29)
45(21)
--
-- < 80% 6''
HRV 170 120V, 60Hz 207 1.83 3040 193
(91)178(84)
167(79)
153(72)
143(67)
133(63)
123(58)
113(53)
103(49)
91(43)
69(33)
40(19) < 80% 6''
ModelSensible efficiency(%) at
56 cfm 80 cfm 160 cfm 120 cfm
HRV 120 74 69 59 63
ModelSensible efficiency(%) at
62 cfm 89 cfm 178 cfm 133 cfm
HRV 170 74 68 58 62
Accessories
g units | 0404 2012 44
Backdraft Dampers Clamps
Air disk valve
Extract air
Supply airExhaust air
Intake airExtract air
Supply air
Exhaust air
Intake air
10 VENTS. Air handling units | 04-2014
Casing
Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
Filter
Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter.
Heat recovery core
Specially designed polymer plate core ensure the top heat recovery efficiency.Whenever heat recovery is not required for unit operation the heat exchanger block can be easily replaced by a “summer” block. The unit is also equipped with the drain pan for condensate.
Defrost system
To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions.
Motors
German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation.
Fans
The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes.
Control
The ventilator is equipped with 3-step switch on it's side panel to choose STANDBY, LOW or MEDIUM mode for continuous operation.
The unit can be equipped with wide range of additional controls (page 24) to switch boost on demand.
Mounting
The unit can be mounted in most positions and in most spaces. Please refer to installation manual for instructions and details.
Warranty
5 year warranty
A Heat Recovery Ventilator is a complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while ex-hausting an equal amount of stale air.
Brig HRV 200, 300
Features
Multizonal efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Silent operation Replaceable filters Simple installation and maintenance Compatible with 6” and 8” air ducts Electronic defrost protection
HRV 200 HRV 300
11
VentsUS.com
VENTS. Air handling units | 04-2014
28 3/8 "
11 3/4 "
7 3/16 "
23 5/8 "
Ø 6"
25 11/16 "
12 3/4 "
Ø 8" 17 5/16 "
36 3/4 "
23 11/16 “
17 15/16 “
28 7/16 “
0
50
100
150
200
250
300
350
400
450
0 20 40 60 80 100 120 140 160 180
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0 50 100 150 200 250 300 350 400
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 300
0
50
100
150
200
250
300
350
0 20 40 60 80 100
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
0 50 100 150 200 250
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 200
217
220
223
Wat
ts
HRV 200 455
459
463
467
Wat
ts
HRV 300
Performance
Model Volts Max. Watts
Max. Amps RPM
Airflow CFM (L/s) Heat re-covery core efficiency,
%
Duct Dia.0,1"
(25Pa)0,2"
(50Pa)0,3"
(75Pa)0,4"
(100Pa)0,5"
(125Pa)0,6"
(150Pa)0,7"
(175Pa)0,8"
(200Pa)0,9"
(225Pa)1,0"
(250Pa)1,2"
(300Pa)1,4"
(350Pa)1,6"
(400Pa)1,8"
(450Pa)
HRV 200 120V, 60Hz 224 1.9 3040 234
(110)226
(107)218
(103)203(96)
191(90)
178(84)
164(77)
152(72)
138(65)
123(58)
86(41)
42(20) - - < 80% 6''
HRV 300 120V, 60Hz 465 3.9 2500 390
(184)380
(179)365
(172)340
(160)315
(149)287
(135)258
(122)233
(110)208(98)
184(87)
137(65)
97(46)
55(26)
22(10) < 80% 8''
HRV 200 HRV 300
Dimensions Accessories
g units | 0404 2012 44
Backdraft Dampers Clamps
Air disk valve
ModelSensible efficiency(%) at
79 cfm 113 cfm 226 cfm 169 cfm
HRV 200 77 71 57 67
ModelSensible efficiency(%) at
133 cfm 190 cfm 380 cfm 285 cfm
HRV 300 70 65 52 59
Extract air
Supply air
Exhaust air
Intake air
12 VENTS. Air handling units | 04-2014
Frigate HRV 60S, ERV 60S Both Heat and Energy Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
Casing
Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
Filter
Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter.
Heat recovery core
The aluminum cross-flow core (HRV 60s) ensures efficient heat recovery and the enthalpic core (ERV 60s) provides both heat&energy recovery.
Defrost system
To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions.
Motor
German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation.
Fans
The ventilator is equipped with supply and exhaust centrifugal fans with forward inclined blades and built-in thermal overheating protection with automatic restart.
The electric motors and the impellers are dynamically balanced in two planes.
Control
The ventilator is supplied with a thyristor speed control. The unit can be equipped with wide range of additional controls (page 24) to
switch boost on demand.
Mounting
The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details.
Warranty
5 year warranty
Features
Effective energy-saving solution Efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Heat recovery (HRV) or Energy Recovery (ERV) Silent operation Replaceable filters Ceiling installation Simple installation and maintenance Compact size
13
VentsUS.com
VENTS. Air handling units | 04-2014
Performance
Model Volts Max. Watts
Max. Amps RPM
Airflow CFM (L/s) Heat re-covery core efficiency,
%
Duct Dia.0,1"
(25Pa)0,2"
(50Pa)0,3"
(75Pa)0,4"
(100Pa)0,5"
(125Pa)0,6"
(150Pa)
HRV 60SERV 60S 120V, 60Hz 44 0.64 63
(30)56
(26)50
(24)38
(18)24
(11)9
(4) < 80% 5’’
6 7/16 "19 1/2 "
8 7/16 "
14 3/4 "Ø 5"
0
25
50
75
100
125
150
0 5 10 15 20 25 30
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0 10 20 30 40 50 60 70
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 60S ERV 60S
39
41
43
45
Wat
ts
HRV 60S ERV 60S
Dimensions Accessories
g units | 0404 2012 44
Backdraft Dampers Clamps
Air disk valve
ModelSensible efficiency(%) at
28 cfm 39 cfm 56 cfm 47 cfm
HRV 60S 67 62 57 60
ModelSensible efficiency(%) at
28 cfm 39 cfm 56 cfm 47 cfm
ERV 60S 69 64 59 62
Extract air
Supply air
Exhaust air
Intake air
14 VENTS. Air handling units | 04-2014
Frigate HRV 120S, ERV 120S Heat and Energy Recovery Ventilators are the complete whole house ventila-tion system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
Casing
Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with a switch to turn the ventilator off when the service panel is opened.
Filter
Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter.
Heat recovery core
Aluminum cross-flow core (HRV 120s) ensures efficient heat recovery and enthalpic core (ERV 120s) provides both heat&energy recovery.
Defrost system
To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions.
Motors
German made high-efficient motor combined with backward inclined impeller delivers exceptionally powerful airflow and high static pressure. Built-in thermal overheating protection with automatic restart makes the motor operation secure
and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation.
Fans
The unit is equipped with supply and exhaust centrifugal fans with backward curved blades and build-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes.
Control
The ventilator is designed for permanent low speed operation. High speed can be turned on and off with the external switch.
Both low and high speed are adjustable. The ventilator's speed is controlled with a 3-step speed switch located on the
ventilator's side panel: LOW mode - minimum speed, MED mode - medium speed. In STANDBY mode the ventilator is controlled from the remote controller SAS 908 (optional supply).
Mounting
The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details.
Warranty
5 year warranty
Features
Effective energy-saving solution Multizonal efficient recovery ventilation Cross flow core with recuperation efficiency up to 80% Heat recovery (HRV) or Energy Recovery (ERV) Silent operation Replaceable filters Ceiling installation Simple installation and maintenance
15
VentsUS.com
VENTS. Air handling units | 04-2014
Performance
Model Volts Max. Watts
Max. Amps RPM
Airflow CFM (L/s) Heat re-covery core efficiency,
%
Duct Dia.0,1"
(25Pa)0,2"
(50Pa)0,3"
(75Pa)0,4"
(100Pa)0,5"
(125Pa)0,6"
(150Pa)0,7"
(175Pa)0,8"
(200Pa)0,9"
(225Pa)1,0"
(250Pa)1,2"
(300Pa)
HRV 120SERV 120S
120V, 60Hz 142 1.23 2460 150
(71)143(67)
137(65)
127(60)
116(55)
104(49)
91(43)
78(37)
64(30)
49(23)
18(8) < 80% 5''
Ø 5"
915/16 "
21"
8 1/4”
20"
0
50
100
150
200
250
300
0 10 20 30 40 50 60 70
0.0
0.2
0.4
0.6
0.8
1.0
1.2
0 20 40 60 80 100 120 140 160
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 120S ERV 120S
high
low
50
75
100
125
150
Wat
ts
HRV 120S ERV 120S
high
low
Dimensions Accessories
g units | 0404 2012 44
Backdraft Dampers Clamps
Air disk valve
ModelSensible efficiency(%) at
50 cfm 71 cfm 143 cfm 107 cfm
HRV 120S 57 53 40 46
ModelSensible efficiency(%) at
50 cfm 71 cfm 143 cfm 107 cfm
ERV 120S 61 57 44 50
Extract air
Supply air
Exhaust air
Intake air ModelSensible efficiency(%) at
40 cfm 57 cfm 115 cfm 86 cfm
HRV 100DS 75 73 61 65
ERV 100DS 78 76 64 69
TRV 100DS 77 75 63 67
ModelSensible efficiency(%) at
52 cfm 74 cfm 148 cfm 111 cfm
HRV 150DS 71 68 58 62
ERV 150DS 75 72 62 66
TRV 150DS 74 71 61 65
16 VENTS. Air handling units | 04-2014
Frigate HRV 100DS, ERV 100DS, TRV 100DS, HRV 150DS, ERV 150DS, TRV 150DS
Casing
Steel casing is covered with high-quality multilayer aluminium and zinc alloy to prevent corrosion. The casing is equipped with switch to turn the ventilator off when the service panel is opened.
Filter
Washable G4 air filters in exhaust and supply air streams. Optional supply: anti grease aluminum filter.
Heat recovery core
Two aluminum cross-flow cores (HRV 100Ds and HRV 150Ds) ensure the most efficient heat recovery.
Two enthalpic cores (ERV 100Ds and ERV 150Ds) provide both heat&energy recovery. Unique combination of aluminum and enthalpic cores attains the best heat&energy recovery efficiency.
Defrost system
To protect the heat recovery core, the freezing electronic protection system is applied. It switches the supply fan off as the temperature sensor requires. Warm extract air defrosts the heat recovery core, then the supply fan switches on and the ventilator continues operating under rated conditions.
Motor
German made high-efficient motor combined with backward inclined impeller
delivers exceptionally powerful airflow and high static pressure. Built-in Thermal Overheating Protection with Automatic Restart makes the motor operation se-cure and reliable. Permanently lubricated ball bearings inside the motor provide long (40000 hours) trouble- and maintenance-free operation.
Fans
The ventilator is equipped with supply and exhaust centrifugal fans with backward inclined blades and built-in thermal overheating protection with automatic restart. The electric motors and the impellers are dynamically balanced in two planes.
Control
The ventilator is designed for permanent low speed operation. High speed can be turned on and off with the external switch.
Both low and high speed are adjustable. The ventilator's speed is controlled with a 3-step speed switch located on the ventilator's
side panel: LOW mode - minimum speed, MED mode - medium speed. In STANDBY mode the ventilator is controlled from the remote controller SAS 908 (optional supply).
Mounting
The unit is mounted suspended to the ceiling with special belts. Please refer to installation manual for instructions and details.
Warranty
5-year warranty
All Heat, Energy and Total Recovery Ventilators are the complete whole house ventilation system designed to bring a continuous supply of fresh air into the house while exhausting an equal amount of stale air.
Features
Effective energy-saving solution Multizonal efficient recovery ventilation Enhanced output capacity Double cross flow cores with recuperation efficiency up to 90% Increased Heat (HRV) and (ERV) Energy Recovery Advantages of HRV and ERV in one unit Silent operation Replaceable filters Ceiling installation
17
VentsUS.com
VENTS. Air handling units | 04-2014
Performance
Model Volts Max. Watts
Max. Amps RPM
Airflow CFM (L/s) Heat re-covery core efficiency,
%
Duct Dia.0,1"
(25Pa)0,2"
(50Pa)0,3"
(75Pa)0,4"
(100Pa)0,5"
(125Pa)0,6"
(150Pa)0,7"
(175Pa)0,8"
(200Pa)0,9"
(225Pa)1,0"
(250Pa)1,2"
(300Pa)1,4"
(350Pa)
HRV 100DSERV 100DSTRV 100DS
120V, 60Hz 139 1.2 3040 120
(57)115(54)
109(51)
98(46)
88(42)
77(36)
65(31)
52(25)
38(18)
24(11) - - < 90% 5’’
HRV 150DSERV 150DSTRV 150DS
120V, 60Hz 215 1.83 3040 150
(71)148(70)
144(68)
136(64)
128(60)
120(57)
111(52)
101(48)
91(43)
79(37)
53(25)
23(11) < 90% 5’’
Ø 5"
12 11/16 "30 3/16 "
8 1/4 "
20 3/8 "
0
50
100
150
200
250
300
350
0 10 20 30 40 50 60 70
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
0 20 40 60 80 100 120 140 160
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 150DS ERV 150DS TRV 150DS
high
low
0
25
50
75
100
125
150
175
200
225
250
0 10 20 30 40 50 60
0.0
0.2
0.4
0.6
0.8
1.0
0 20 40 60 80 100 120
Stat
ic P
ress
ure
[Pa]
Flow Rate, [L/s]
Stat
ic P
ress
ure
[in. W
G]
Flow Rate, [CFM]
HRV 100DS ERV 100DS TRV 100DS
high
low
50
75
100
125
150
Wat
ts
HRV 100DS ERV 100DS TRV 100DS
high
low
70
110
150
190
230
Wat
ts
HRV 150DS ERV 150DS TRV 150 DS
high
low
Dimensions Accessories
g units | 0404 2012 44
Backdraft Dampers Clamps
Air disk valve
The Single Room Total Recovery ventilator TwinFresh S is an easy and
effective solution for rooms and smaller areas.
Front grille (1)
Modern design of the front grille makes it look great in any interior.Easy access for filter cleaning or replacement. The front grille is made of high quality snow-white ABS plastic.
Air filtration (2)
Two G3 built-in filters provide fresh air free of dust, pollen, insects.
Motor (3)
The latest EC-motor technology ensures low energy costs.The motor has integrated overheating protection and ball bearings for longer service life.
Polymer ceramic energy accumulator (regenerator) (4)
The ventilator includes a high-tech polymer ceramic energy accumulator with regenerating efficiency up to 91%.
Control and operating modes
The automation system has four operating patterns: 1. Ventilation mode (extract or supply mode) at low speed with air capacity 20.6 CFM; 2. Ventilation mode (extract or supply mode) at high speed with air capacity 34.1 CFM; 3. Reverse mode (regeneration) at low speed with air capacity 20.6 CFM; 4. Reverse mode (regeneration) at high speed with air capacity 34.1 CFM
The required operation mode is selected using the control panel supplied with the model TwinFresh SA. The control panel for the model TwinFresh S is avail-able upon separate order.
Exterior Protection (5)
The exterior is constructed of aluminum covered with a special polymer coating to ensure long-lasting protection from the elements. A grill protects water and foreign objects from entering the unit.
18 VENTS. Air handling units | 04-2014
S i n g l e R o o m T O T A L R e c o v e r y V e n t i l a t o r s
The ventilator with a square air duct is specially designed for easy mounting in new construction.
TwinFresh S-60, S-60-2
Supply/extract mode
Reverse mode
High speed
Low speed
On Off
Supplied with TwinFresh SA only
Benefits
No need to pay for air ducts No need to pay for grilles No need to pay for installation of complicated ventilation duct system Extremely high ERV core efficiency up to 91%
1
2
3
4
5
Features:
Efficient supply and exhaust single room ventilation High-tech polymer ceramic energy accumulator with regenerating
efficiency up to 91% EC-motor Integrated automation with four operating patterns Silent operation (0.5 – 0.81 Sones) Easy installation
Air purification with two built-in G3 filters Rated for continuous operation
19
VentsUS.com
VENTS. Air handling units | 04-2014
How the TwinFresh S Works
CYCLE I. Warm stale air is extracted from the room passing through the ceramic
accumulator, which captures up to 91% of the thermal energy of the air being ex-
tracted. As the accumulator gets heated, the ventilator switches to air supply mode.
CYCLE II. As the fresh outside air passes the opposite way through the accumula-
tor, it absorbs the heat and moisture which was extracted from the room air that
was exhausted. As the temperature of the accumulator decreases, the fan switches
back to extraction mode and the cycle starts all over again. The ventilator changes
its operation mode for supply or extract ventilation every 70 seconds. This time
interval can be adjusted during installation from 30 to 120 seconds.
70se
c.
AIR
SUPPLY
AIR EXTRACT70se
c.
CYCLE I
CYCLE II
68oF
14oF
68oF
14oF
14oF
68oF
68oF
14oF
Technical data
Overall dimensions [inch]
10"
67/16"
101/16" – 181
1/16"
10 13/16"
213/1
6"
115/
8"
123/8"
123/
8"
67/16"
811/1
6"
10 13/16"
43/4" - 1
3"
TwinFresh S-60
TwinFresh S-60-2
Model Speed Voltage [V]
Power [W]
Air capacity [CFM]
Rotation speed [min-1] Sones Ingress protection
rating
TwinFresh S1
120/60 Hz2,4 20.6 1150 0.5
IP 452 3,0 34.1 2100 0.81
*In reverse mode the stated air capacity is shared for both directions
Accessories
Replaceable front grilles
RV TwinFresh S alumat
Grey metallic
RV TwinFresh S aluNatural brushed
aluminium
RV TwinFresh S gold
Natural gold painted aluminium
RV TwinFresh S chrome
Natural mirror aluminium
Control panel
KVS
Power transformer
TRF 110/12-6 (6 W)
TRF 110/12-12 (12 W)
The Single Room Total Recovery ventilator TwinFresh R is an easy and
effective solution for rooms and smaller areas.
Front grille (1)
Modern design of the front grille makes it look great in any interior. The grille is fitted with a thermal actuator and automatic louvre shutters that are opened during operation of the ventilator and are closed during standby. The front grille is made of high quality snow-white ABS plastic.
Air filtration (2)
Two G3 built-in filters provide fresh air free of dust, pollen, insects.
Motor (3)
The latest EC-motor technology ensures low energy costs. The motor has inte-grated overheating protection and ball bearings for longer service life.
Polymer ceramic energy accumulator (regenerator) (4)
The ventilator includes a high-tech polymer ceramic energy accumulator with regenerating efficiency up to 91%.
Control and operating modes
The automation system has four operating patterns: 1. Ventilation mode (extract or supply mode) at low speed with air capacity 14.7 CFM; 2. Ventilation mode (extract or supply mode) at high speed with air capacity 29.4 CFM; 3. Reverse mode (regeneration) at low speed with air capacity 14.7 CFM; 4. Reverse mode (regeneration) at high speed with air capacity 29.4 CFM
The required operation mode is selected using the control panel supplied with the model TwinFresh RA. The control panel for the model TwinFresh R is avail-able upon separate order.
Exterior Protection (5)
The exterior is constructed of aluminum covered with a special polymer coating to ensure long-lasting protection from the elements. A grill protects water and foreign objects from entering the unit.
20 VENTS. Air handling units | 04-2014
Features:
Efficient supply and exhaust single room ventilation High-tech ceramic energy accumulator with regenerating efficiency up to 91% EC-motor
Integrated automation with four operating patterns Silent operation (0.5 – 0.81 Sones) Easy installation Air purification with two built-in G3 filters Rated for continuous operation
TwinFresh R-50, R-50-2
The ventilator with a round duct is specially designed for easy mounting in refurbished and reconstructed ready-built buildings.
Supply/extract mode
Reverse mode
High speed
Low speed
On Off
Supplied with TwinFresh RA only
Benefits
No need to pay for air ducts No need to pay for grilles No need to pay for installation of complicated ventilation duct system Extremely high ERV core efficiency up to 91%
1
2
3
4
5
21
VentsUS.com
VENTS. Air handling units | 04-2014
70se
c.
AIR
SUPPLY
AIR EXTRA
CT
70se
c.
CYCLE I
CYCLE II
68oF
14oF
68oF
14oF
14oF
68oF
68oF
14oF
6
6
Technical data
Overall dimensions [inch]
Model Speed Voltage [V]
Power [W]
Air capacity [CFM]
Rotation speed [min-1] Sones Ingress protection
rating
TwinFresh R1
120/60 Hz1,4 14.7 570 0.5
IP 452 3,0 29.4 1100 0.81
*In reverse mode the stated air capacity is shared for both directions
61/8"
10"
1013/
16"
213/1
6"
913/16" - 1
81/2"
8 3/8"
43/4" - 133
/8"
95/8"
93/4"
87/16
"
8 3/8"
61/8"
TwinFresh R-50
TwinFresh R-50-2
Accessories
Round plastic grille MV 150 bVs
Rectangular plastic grille MV 125 VDs
Stainless steel outer hood MV 152 bVs N
Angle mounting kit NP 60х204-0021
Control panel
KVR
Power transformer
TRF 110/12-6 (6 W)
TRF 110/12-12 (12 W)
How the TwinFresh R Works
CYCLE I. Warm stale air is extracted from the room passing through the ceramic
accumulator, which captures up to 91% of the thermal energy of the air being ex-
tracted. As the accumulator gets heated, the ventilator switches to air supply mode.
CYCLE II. As the fresh outside air passes the opposite way through the accumula-
tor, it absorbs the heat and moisture which was extracted from the room air that
was exhausted. As the temperature of the accumulator decreases, the fan switches
back to extraction mode and the cycle starts all over again. The ventilator changes
its operation mode for supply or extract ventilation every 70 seconds. This time
interval can be adjusted during installation from 30 to 120 seconds.
Casing (1)
Polymer coated metal casing decorated with mirror stainless steel and internally filled with 9/16" thermal and sound insulating layer. Modern unit design makes it match well with any interior. The removable front panel provides easy access for filter cleaning or replacement. Air is supplied to the room and exhausted outside through two 5" air ducts.
Air filtration (2)
Two G4 built-in filters provide cleaning of supply and extract air. The filters serve to ensure supply of fresh air free of dust, pollen and insects and protect the unit from soiling.
Motor (3)
Axial fans are powered by energy-efficient EC-motors. The motors are equipped with built-in thermal overheating protection and ball bearings for longer service life.
Heat recovery core (4)
The ventilator is equipped with a high-tech plate counter-flow aluminium heat recovery core reaching up to a 78% recovery efficiency. Using the MICRA in both cooling and heating seasons results in considerable energy savings.
Freeze protection
The MICRA includes special thermostats that prevent any condensate from freezing.
Control unit (5)
The unit is powered through an integrated pulser unit with a wide range of sup-ply voltage from 100 V to 240 V and frequency from 50 to 60 Hz. The power unit has integrated protection for various emergencies including short circuit, overload, voltage jumps, reverse polarity in output circuits.
Control and operation modes
Automatic system enables three operation modes: 1. Supply and exhaust ventilation at minimum air capacity
17.7 CFM and minimum noise level 0.38 Sones.2. Supply and exhaust ventilation at medium air capacity
26.5 CFM and minimum noise level 0.42 Sones.3. Supply and exhaust ventilation at medium air capacity
35.3 CFM and minimum noise level 1.0 Sones.
22 VENTS. Air handling units | 04-2014
Features
Efficient heat recovery ventilation for separate rooms Up to 90% energy recovery efficiency. EC-motor Three operating modes Silent operation (0.38 – 1.0 Sones) Air cleaning with two G4 built-in filters Easy mounting Suitable for continuous operation
Micra 60 is the single room heat recovery ventilator for larger rooms and areas, including apartments and small commercial spaces. No need to connect air ducts. A great solution for simple and efficient ventilation in retrofits.
Single room HRV MICRA 60
1
2
3
4
5
23
VentsUS.com
VENTS. Air handling units | 04-2014
Supply air
Extract air
How it Works
Fresh air from outside moves through the filter and core. Warm stale air from the room moves through the filter and core and then is exhausted outside.
The thermal energy of the extracted warm inside air is transferred to the fresh outside air that is being drawn in.
The intake and extract air flows are fully separated.
Overall dimensions [inch]
Technical data
Model Speed Voltage Power [W]
Current [A]
Air capacity [CFM]
Rotation speed [min-1] Sones Ingress protection
rating
Micra 60
1100-240 V
50-60 Hz
4,2 0,02 17,7 1165 0.38
IP 222 9,6 0,04 26,5 1720 0.42
3 15,4 0,07 35,3 2685 1.0
Accessories dimensions [inch]
Mounting set MK MICRA 60:
two air ducts PVC1911/16’’ long; one outer metal twin hood.
Mounting metal master plate MP MICRA 60.
Used to fix air ducts in required position and to align the unit branch pipes and air ducts precisely. The master plate is installed during general construction stage.
14"
75/16"
25/16"
73/8"
О 47/8"
151/2"
2011
/16"
43/4"
151/4"
203/
8"
51/8"
51/8"
Heat recovery core
Supply filter
Extract filter
24 VENTS. Air handling units | 04-2014
Optional remote controls
OFFOFF MAXMAX
HUMIDITY CONTROL
10 %
20%
30%
40%
TOGGLE SWITCH
OFFOFF
ONON
TRANSMITTERCO2
SPEED CONTROL
LOW
STANDBY
MED
Thermostat SAS908PIT
The modulating digital thermostat is designed to select one of three fan speeds. As the thermostat is off the unit is switched to STANDBY mode.
The product also provides proportional-integral temperature regulation of fancoil dampers, equip-ment for zonal heating in commercial applications and transfers air conditioning control signals.
Remote dehumidistat
Location: kitchen and bathroom, SPA or swim-ming pool (anywhere humidity is a concern).
Provides high speed ventilaion when humidity level selected setting.
Ventilator
Important – Base module Low Voltage is 24 Volt AC. Do not connect external power sources to the ventilator!
Crank Timer
Location: bathroom or kitchen area to bring on high speed ventilation as required
Crank Timer – 60 min
Toggle switch
Important – Base module Low Voltage is 24 Volt AC. Do not connect external power sources to the ventilator!
Speed control
Each unit is equipped with one three-key speed switch to select low speed or medium speed. In STANDBY mode the unit is waiting to response to external signal.
All double-wire devices switch the units to maximum speed irrespective of the switch position.
CO2 transmitter
For offices or other public places. Provides high speed ventilation when CO2 level
exceeds selected setting.
2 Wireconrtol Devices (Low Woltage)
10
20
30
40
50
60OFF
CRANK TIMER
25
VentsUS.com
VENTS. Air handling units | 04-2014
Electrical accessories compatibility
Thermostat
SAS908PIT
Remote
dehumidistat
CO2
transmitter
Crank
Timer
Toggle
switch
Speed control
RS 1-400
Four position
switchControl unit
OFFOFF MAXMAX
HUMIDITY CONTROL
10 %
20%
30%
40% TRANSMITTERCO2
10
20
30
40
50
60OFF
CRANK TIMER
TOGGLE SWITCH
OFFOFF
ONON
Vents VUT 200 mini •
Vents Brig HRV 120 • • • • •Vents Brig HRV 170 • • • • •Vents Brig HRV 200 • • • • •Vents Brig HRV 300 • • • • •Vents Frigate HRV 60S • • • • •Vents Frigate ERV 60S • • • • •Vents Frigate HRV 120S • • • • •Vents Frigate ERV 120S • • • • •Vents Frigate HRV 100 DS • • • • •Vents Frigate ERV 100 DS • • • • •Vents Frigate TRV 100 DS • • • • •Vents Frigate HRV 150 DS • • • • •Vents Frigate ERV 150 DS • • • • •Vents Frigate TRV 150 DS • • • • •
TwinFresh R •
TwinFresh S •
Micra 60 •
26 VENTS. Air handling units | 04-2014
Heat Recovery Ventilators (HRV)
Area of house Sq. Ft
Up To 1200 Up To 2000 Up To 2400 Up To 3000 Up To 3400 Up To 4000 Up To 6000
Model(HRV)
HRV 60S HRV 100DS VUT 200 mini HRV 120S HRV 120 HRV 150DS HRV 170 HRV 200 HRV 300
Duct Dia. 5'' 5'' 4'' 5'' 6'' 5'' 6'' 6'' 8''
Max. Watts 44 139 207 142 135 215 207 465 224
Airflow CFM (L/s) 56 (26) 115 (54) 125 143 (67) 160 (76) 148 (70) 178 (84) 226 (107) 380 (179)
Efficiency of heat ex-changer, %
< 80% < 90% < 80% < 80% < 80% < 90% < 80% < 80% < 80%
Energy Recovery Ventilators (ERV)/Total Recovery Ventilators (TRV)
Area of house Sq. Ft
Up To 1200 Up To 2000 Up To 2400 Up To 3000
Model(ERV)
ERV 60S ERV 100DS HRV 120S ERV 150DS
Model(TRV)
TRV 100DS TRV 150DS
Duct Dia. 5'' 5'' 5'' 5''
Max. Watts 44 139 142 215
Airflow CFM (L/s) 56 (26) 115 (54) 143 (67) 148 (70)
Efficiency of heat exchanger, % < 80% < 90% < 80% < 90%
Certification
Quick Selection Table
Tel: 1-888-640-0925Tel: 513-348-3853Fax: [email protected] Kenwood RoadCincinnati, Ohio 45242
04/2014