air conditioning technical data -...

15
Air Conditioning Technical Data Wall mounted unit EEDEN14-035 ATXV-AB

Upload: others

Post on 16-Jan-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

Air Conditioning

Technical DataWall mounted unit

EEDEN14-035

ATXV-AB

Page 2: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB
Page 3: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

• Split - Sky Air • ATXV-AB 1

• Indoor Unit • ATXV-AB

TABLE OF CONTENTSATXV-AB

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

3 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

5 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

6 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Sound Pressure Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Page 4: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

• Indoor Unit • ATXV-AB

1

2

1 Features

oor Unit it - Sk V-AB l mounte

Ind Spl ATX Wal • The infrared remote control is user friendly and equipped with a timer function that enables you to programme the unit to start or stop at your desired time.

• Turbo mode allows to rapidly heat up or cool down the room in a couple of minutes

• 24 hour timer can be set to start heating or cooling anytime during a 24 hour period

• Vertical auto swing moves the discharge flaps up and down for efficient air and temperature distribution throughout the room

• Flat, stylish front panel blends easily within any interior décor and is more easy to clean

Fan only Comfortable sleeping mode

Vertical auto swing

Auto fan speed Fan speed steps

Dry programme 24 hour timer Infrared remote control

Auto-restart

• Split - Sky Air • ATXV-AB

Page 5: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

3

2

• Indoor Unit • ATXV-AB

2 Specifications

2-1 Technical Specifications ATXV25AB ATXV35AB ATXV50AB ATXV60AB

Dimensions Unit Height/Width/Depth

mm 275/845/180 298/940/200 315/1,007/219

Packed unit Height/Width/Depth

mm 370/918/258 383/1,013/300 398/1,076/328

Weight Unit kg 9 12 14

Packed unit kg 12 15 17.5

Fan Air flow rate Cooling High m³/min 10 9.7 14.2 16.7

Nom. m³/min 8.3 13 13.3

Low m³/min 6.7 10.8 11.7

Silent operation

m³/min 5 9.2

Sound power level Cooling dBA 50 51 53 57

Sound pressure level Cooling High/Nom./Low/Silent operation

dBA 41/39/34/28 42/40/35/30 48/43/40/35 51/47/42/39

Refrigerant Type R-410A

Piping connections Liquid OD 6.35

Gas OD 9.52 12.7 15.9

2-2 Electrical Specifications ATXV25AB ATXV35AB ATXV50AB ATXV60AB

Power supply Phase 1~

Frequency Hz 50

Voltage V 220-240

• Split - Sky Air • ATXV-AB 3

Page 6: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

• Indoor Unit • ATXV-AB

3

4

3 Dimensional drawings3 - 1 Dimensional Drawings

• Split - Sky Air • ATXV-AB

Page 7: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

3

3

• Indoor Unit • ATXV-AB

3 Dimensional drawings3 - 1 Dimensional Drawings

• Split - Sky Air • ATXV-AB 5

Page 8: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

• Indoor Unit • ATXV-AB

4

6

4 Piping diagrams4 - 1 Piping Diagrams

• Split - Sky Air • ATXV-AB

Page 9: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

3

5

• Indoor Unit • ATXV-AB

5 Wiring diagrams5 - 1 Wiring Diagrams - Single Phase

A:B:C:D:E:F:G:H:J:K:

L:M:N:

BN:BK:

ABC

DE

F

G

HJ

K

L

M

N

BU:YEGN:

O

O:

ATXV25AB

4D087781A

• Split - Sky Air • ATXV-AB 7

Page 10: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

• Indoor Unit • ATXV-AB

5

8

5 Wiring diagrams5 - 1 Wiring Diagrams - Single Phase

A:B:C:D:E:F:G:H:J:K:

L:M:N:

BN:BK:

ABC

DE

O

G

HJ

K

L

M

N

BU:YEGN:

F

O:

ATXV35AB

4D087782A

• Split - Sky Air • ATXV-AB

Page 11: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

3

5

• Indoor Unit • ATXV-AB

5 Wiring diagrams5 - 1 Wiring Diagrams - Single Phase

A B C

D E

FG

H

J K

L

M

N

O

P

A:B:C:D:E:F:G:H:J:K:

L:M:N:O:P:

Q

Q:

ATXV50AB

4D087784A

• Split - Sky Air • ATXV-AB 9

Page 12: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

• Indoor Unit • ATXV-AB

5

10

5 Wiring diagrams5 - 1 Wiring Diagrams - Single Phase

A B C

D E

FG

H

J K

L

M

N

O

P

A:B:C:D:E:F:G:H:J:K:

L:M:N:O:P:

Q

Q:

ATXV60AB

4D087785A

• Split - Sky Air • ATXV-AB

Page 13: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

3

6

• Indoor Unit • ATXV-AB

6 Sound data6 - 1 Sound Pressure Spectrum

• Split - Sky Air • ATXV-AB 11

Page 14: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB
Page 15: Air Conditioning Technical Data - Edilportaleimg.edilportale.com/catalogs/prodotti-154274-cat25897c7366494e349f5a1... · • Indoor Unit • ATXV-AB 1 2 • Split - Sky Air • ATXV-AB

Daikin Europe N.V. participates in the Eu-rovent Certification programme for LiquidChilling Packages (LCP), Air handling units(AHU) and Fan coil units (FCU), Check on-going validity of certificate online: www.eu-rovent-certification.com or using:www.certiflash.com

EE

DE

N1

4-0

35

05/

14

• C

opy

righ

t Dai

kin

The

pre

sent

pu

blic

atio

n s

up

erse

des

EE

DE

N1

3-03

5

The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.has compiled the content of this leaflet to the best of its knowledge. Noexpress or implied warranty is given for the completeness, accuracy, re-liability or fitness for particular purpose of its content and the productsand services presented therein. Specifications are subject to changewithout prior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arising from or re-lated to the use and/or interpretation of this leaflet. All content is copy-righted by Daikin Europe N.V.

BARCODE Daikin products are distributed by:

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende