DESCRIPTION
without saying prevention is always better than cure. Dust prevention is TECHNOCRACY PVT. LTD. AIR CURTA Invisible dust has a telling effect on sensitive electronic equipment. It goes no longer a luxury but a necessity in almost all spheres of life. ® IN • Acm-4106-I Models: TECHNOCRACY PVT. LTD. IN ®TRANSCRIPT
![Page 1: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/1.jpg)
AIR CURTAIN
TECHNOCRACY PVT. LTD.
®
Acm-4106-lModels:
AIR CURTAINInvisible dust has a telling effect on sensitive electronic equipment. It goes
without saying prevention is always better than cure. Dust prevention is
no longer a luxury but a necessity in almost all spheres of life.
![Page 2: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/2.jpg)
AIR CURTAIN
Models: ®
• Acm-4106-I
TECHNOCRACY PVT. LTD.
AIR CURTAIN
![Page 3: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/3.jpg)
®
Invisible dust has a telling effect on sensitive electronic
equipment. It goes without saying prevention is always better
than cure. Dust prevention is no longer a luxury but a
necessity in almost all spheres of life.
Application
• Pharmaceuticals & Food Industries• Laboratories • Clean Rooms • Computer Facilities • Cold Storages • Show Rooms & Restaurants • Electrical & Electronic Industries
Features
• Weiber air curtains are quiet enough not to disturb
occupants, allowing efficient continuous operation in
all installations.
• The seasons in which doors can be left open are
extended with air screens. Customers are attracted to
shops with open doors.
• Heated units give a feeling of welcoming warmth as
the customer enters the space, plus the entrance
remains dry.
• The reduction in drafts through the openings increases
the energy efficiency of the building.
• The air velocity is optimized to reduce entry of insects,
pollen and dust, while not disturbing occupants.
• Weiber air curtains are elegantly styled and
installation is simple.
• Superior motor technology ensures reliable operation
and long life span.
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
AIR CURTAIN
![Page 4: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/4.jpg)
®
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
AIR CURTAIN
![Page 5: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/5.jpg)
5.1 Scope
The scope of this section comprises the supply, erection,
testing and commissioning of Air Curtains units conforming
these Specifications and in accordance with the requirements
of the Drawings and of Schedule of Quantities.
5.2 Type
The Air Curtain units are Non Re-Circulating, preferably
installed horizontal to the ground. Installed with anchor
fasteners to the wall or mounted to the ceiling or frame with
proper supports. The discharge nozzle shall be uniform all
through, and the Air curtain shall fully cover the Door
opening.
5.3 Capacity
The Air Curtain should be sized according to the width of the
Door, and Air throw shall be selected as per the height of the
Door, or the capacities shall be as shown on Drawings and
indicated in Schedule of Quantities.
5.4 Cabinets
Cabinets are constructed of 18 SWG CRC iron sheet steel and
powder coated. Corners are rounded without break lines.
The cabinets have good finish and the access panels and the
mountings are so provided for easy removal. All the nuts and
bolts visible are nickel coated.
5.5 Blower housing
The blower housing are constructed of CRC Sheet and are
powder coated, and shall be engineered to provide the
required outlet velocity with minimum noise level.
5.6 Fans
Fans installed in Air Curtain are centrifugal, forward curved
double inlet, lightweight dynamically balanced made in
Aluminum. Impellors shall have Die Cast Aluminum double-
ended Hubs. Ring and Back Plate are made of 16 SWG
Aluminum Sheet and Blades are made in TABLOCK Design,
with 22 SWG Aluminum Sheet. Performance of Impellor is
tested as per AMCA Standards and Guaranteed.
5.7 Motor
Motor are 220 ? 10% volts, 50 cycles single phase, four pole
START & RUN type capacitors. Motors have been provided
®
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
AIR CURTAIN
![Page 6: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/6.jpg)
with Thermal overload protectors. The Core is made in
.CRNO. (Cold Rolled Non Oriented) Silicon Sheet. Motors
have extended shaft on both the sides, with 15mm as the
shaft Diameter.
5.8 Motor Mounting
Motor Mounting have been so provided that it should have
24 Nos. of vibration isolators between each motor and the
chassis, so placed that it can dampen vibration in all the axis
i.e. X, Y and Z. Vibration isolator are made in silicon rubber,
to resist Temperature rise.
5.9 Painting
Powder Coating is done on the unit. The colour of the powder
used is Ivory from Asian Paints Grade HYG320, else any
other, if specified. Proper treatment shall be done on each
panel before powder coating.
6.0 Noise Level
Maximum speed < 60 dbMinimum speed < 50 db
Frequently Asked Questions Weiber Air Curtains
Should the "Weiber" air curtain be mounted inside or
outside the Room?
• A "Weiber" air curtain will operate with equal efficiency
on either side of there are general rules to remember as
follows: Whenever installing an air curtain the door should
open the opposite without rupturing the curtain. Exceptional
situation can be only when open for a very long time.
• When used over freezer doors or cold room, outside
installation is fans tend to gather moisture and freeze, which
eventually form a snow tangential flow fan causing it to lose
operational efficiency, ifmounted l If there are people
working inside, near the door opening, an outside suggested
because of the humming sound from the unit in operation,
sound to dissipate.
• As a dust barrier, we suggest to install the air curtain on
the cleaner l Going by a thumb rule, an air curtain should be
installed - for best absorption duct at floor level - on the
opposite side of the source of what prevented i.e. for the
®
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
![Page 7: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/7.jpg)
prevention of conditioned air losses, on the warmer think of
vertically installed units for horizontal air drafts only under
cases, are conducive for such an installation.
How far above the doorway should the "Weiber" air
curtain be mounted?
It is advisable to install the air curtain around one half two
inches above whenever possible. The closer to the door top,
the more effective will curtain can be hung away from the
wall, if there is any hindrance for formation. But adequate
care needs to be taken to cover the sides between curtain
formations.
What happens, if "Weiber" air curtain used is much
smaller than the width of the door?
It is wrong to install an air curtain smaller than the width of
the door unprotected area on the sides. In an ideal situation
the air curtain should completely with one inch overlapping
on either sides of the door frame protection. Competitive
manufacturer sometimes supply incorrect units us. Their
units contain extreme side deflectors to spread the air on
each curtains the air pattern will go across the width but is
irregular as one air looses much of its velocity by the time it
reaches the ground.
How far beyond the edge of the curtain chassis does
the air spread is the depth?
Since the air leaves discharge nozzle at a very high velocity,
the curtain two inches on each side. The depth of the curtain
air is about one foot away from the discharge nozzle.
When would a vertical mount be feasible?
When installation is not possible over the top of the doorway,
the "Weiber" mounted along the door opening and the air
flow run horizontally. Due unit operates efficiently in vertical
position.
How long does it take to install an "Weiber" air
curtains?
The average time required to install the unit is around two
hours. After installation the time can usually be cut to 1 1\2
hours.
®
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
![Page 8: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/8.jpg)
Micro processor BasedHOT AIR OVEN
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
When an "Weiber" air curtain is mounted over a cooler
doorway, can removed and the air curtain allowed to
operate continuously?
YES. The "Weiber" air curtain is equipped with continuous
duty motors and many years, trouble free.
What happens to the air when it hits the ground?
When the air reaches the floor level it will divide, sending the
air partially simultaneously and causing a drift both ways at
the floor line. When using the "Weiber" air curtain for insects
and dust control, the directional outlet nozzle should be
directed outward not only to repel the insects allow the least
amount of air to come inward when hitting the floor. If
mounted on the outside of the doorway and used for the
purpose of refrigerated rooms when the door is open, the
directional vanes should outward. Mounted on the inside of
the freezer or cooler the vanes should the refrigerated
rooms.
If the velocity of an air curtain is too great how can it be
slowed
Velocity can be slowed down by using pre-filters at the intake
to restrict suction grill. This restriction should not be used
while using the air curtain and dust.
What happens when man or material goes through an
entrance curtain mounted over it? Is the air curtain still
effective?
When used over warehouse or entrances for the purpose of
keeping insects curtains efficiency will not be affected by the
passage for man or material.
What is a micro switch and when is it used
A micro switch is used to start the air curtain when the door is
open and is closed, to avoid continuous operation of the
curtain. There are various switches used - such as plunger
type, roller type etc. However, it is always the micro switch
®
![Page 9: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/9.jpg)
®
ACMAS TECHNOCRACY PVT. LTD.www.measuring-meters.com | www.acmasindia.com | www.scientificlaboratoryequipments.com
and allow "Weiber" air curtain to operate continuously,
opening and closing of the doors, since any and every air
curtain takes RPM to full load RPM, by which time a human
being is well past through
Can a micro switch be used on all types of doors?
NO. They will not work on swinging doors that open both
ways. They doors that open one way, sliding doors and roll-
up doors/shutters.
If air leaving the nozzle does not seem to have much
velocity reason?
a. The cause is probably incorrect rotation of the tangential
flow fan. three phase motors. If this is the problem, two wires
to the motor within the motor, need to be reversed for correct
rotation.
b. The tangential flow fans / pre-filters are choked, hence the
air displacement place sufficiently. If this is the case, blow off
the dust or other material a high velocity industrial blower.
Can filters be used in front of a suction side?
YES. Filters can be used in conjunction with suction grill or
along. Filters an excessive amount of dust and dirt in the air.Can the "Weiber" air curtain be used to hold in extreme heat
inside industrial ovens?
YES. As long as the air curtain is mounted on the outside of
the oven. the more effective the installation as the percent of
air loss is held to
What type of maintenance does the "Weiber" air curtain
require?
All motor's & units have lifetime lubricated sealed ball
bearings making unnecessary. But blowing or wiping dust off
the fans and motor whenever advisable to ensure maximum
performance.
![Page 10: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/10.jpg)
TECHNOLOGY with HUMAN TOUCH
![Page 11: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/11.jpg)
TECHNOLOGY with HUMAN TOUCH
TECHNOCRACY PVT. LTD.
We are having Representatives in 55 Countries
please visit our
International Dealers Section
to contact your nearest ACMAS Representative
![Page 12: air-curtain](https://reader031.vdocument.in/reader031/viewer/2022020423/568c33c91a28ab02358e0469/html5/thumbnails/12.jpg)
TECHNOCRACY PVT. LTD.
www.acmasindia.com | www.scientificlaboratoryequipments.com | www.measuring-meters.com
SALES OFFICE (INDIA)
312-313, Vardhman Capital Mall, L.S.C. 10, GulabiBagh, Delhi-110052, INDIA
Tel: 0091-11-23646703, 23643054
(M) +91-9313971681| Email: [email protected]
SALES OFFICE (HONG KONG)
Unit D 28 11/f Wing Tat Comm, Bldg 97, Bonham Strand East, Sheung Wan, HONG KONG (PRC).
Tel: 0086-13929598046 | 0086-18922303099
Email: [email protected]
SHOWROOM
141, Rai Industrial Estate, Rai, Sonepat, Haryana-131029, INDIA
Tel: 0091-0-9312219738 (M) +91-9717741167
Email: [email protected]
SALES OFFICE (RUSSIA)
Inmed Trade Street, Ozerkovsky Embankment, Unit No 50 Straine-1, Off-502, Moscow, RUSSIA
Tel: 0049-79592345 | Email: [email protected]
An ISO 9001:2208 | ISO 14001:2008 | ISO 13485WHO:GMP Products | GLP Compliant Products