  • Slide 1
  • Air Handling Products AHR 2015 Chicago Navy Pier January 25, 2015 1
  • Slide 2
  • AHU and Fan Coils Agenda 11:00 am to Noon 2014 Road Trip Update on recently launched products HHA Critical Environment AHU - Update NDB Premium Vertical AHU New Products Planned BR Rooftop AHU Redesign Direct-drive HBB New Website Demo of HHA, NDB, and DV units 2
  • Slide 3
  • 3 On the Road Again In Rain and Snow or Sun and Heat. With a Trailer & Generator -
  • Slide 4
  • 4 On the Road Again In Conference Rooms & Stairwells - And In Between Double Entrance Doors
  • Slide 5
  • 5 On the Road Again Weve Gotten the Message out with Your Help Magic Aire is Committed to New Product Development and Meeting the Needs of our Customers!
  • Slide 6
  • 6 On the Road Again NDB Preferred air handler for large surburban school district. Accepted as equal and then won bid on large job. Then specified BOD by three other engineers on new projects. Southeast school BOD I wont accept anything less than this, said the engineer job won. HHA Southeast Medical Office Building developer Metropolitan hospital renovations
  • Slide 7
  • Model HHA Update High Static Air Handling Unit 7
  • Slide 8
  • MERV-8/13 Pre-filter and HEPA Final Filter Slide Out Coil Section (12 rows max.) HEPA Filter Blower Section w/ Plenum Fan Airflow Pre-filter MERV 8/13 8
  • Slide 9
  • Coil Section Blower Section w/ Plenum Fan Pre-filters MERV 8/13 Slide Out Coil Section 12 rows max. HEPA Filter Accessory Airflow MERV-8/13 Pre-filters Only 9
  • Slide 10
  • High-static Plenum Fan 400 2,000 Nominal CFM at 3.0 7.0 TSP Backward-curved impeller 3600 nominal RPM Direct-drive motor with VFD variable-speed control Option: remote-mounted potentiometer speed control 208-230V/1ph, 208-230V/3ph or 460V/3ph voltages (others pending) Cabinet Construction for optimal sound Isolated Motor/Blower sled 2 Double-wall, galvanized steel liners Powder-coated exterior panels Optional Silver-ion Anti-Microbial powder-coated inner liners Hinged side-access doors for blower/filter service Slide out coil & drain pan HHA Series-Features 10
  • Slide 11
  • Filtration Options High Capacity HEPA filter 2 MERV-8 and 4 MERV-13 pre-filter section (extend HEPA filter life 5X) Option: one pre-filter only Coil Options Up to 12 rows total 1, 2, 4, and 6-row coil options Hydronic, DX (R-22 or R-410A) and steam coils available Stainless Steel Drain Pan for Improved IAQ Double-sloped, ASHRAE 62 compliant Option: Silver-ion Anti-Microbial coating Upcoming Additional Options Differential pressure measurement UV lights Constant-volume airflow 120V/1ph., 277/1ph., 575/3ph. Voltages Stainless steel cabinet HHA Series-Features 11
  • Slide 12
  • Optional Ceiling-mounted HEPA Filtration Diffuser Features HEPA filter, rated at 99.99% at 0.3pm For lay-in ceiling installation 10 diameter connection optional damper Gel seal or Gasket seal Several filter depth options Permanent diffuser Replaceable filter (from face) 12
  • Slide 13
  • Progress so far Released in New Magic selection software Significant progress in several markets Road Show helps demonstrate features, low sound Medical Office Buildings (MOB), including Tenant Improvement DX has been common 8-row CW coil (special) allows low LAT with significant entering OA Potential New Features Based on Feedback MERV 14 6/12 final filter option Seismic rating Mixing Box UV Light Electric Heat Humidifier module (potential) Hanging brackets Update after 2014 Launch 13
  • Slide 14
  • 14 Model NDB Vertical Direct-drive Air Handling Unit
  • Slide 15
  • 15 800, 1200, 1600, 2000 CFM Double-wall, hinged access Front-access for all service Slide-out blower & coils R-410A or CW Cooling HW, Steam, or Electric Heat Upflow top or rear discharge Variable or Multi-speed blower Optional R/A Plenum Optional Outside Air damper
  • Slide 16
  • Easier Installation & Maintenance Hinged, removable blower access door with integral electrical disconnect Slide-out blower and coil Quarter-turn latches on all access doors Hinged, no-tool filter access Belt-less blower All service access from the front
  • Slide 17
  • Vertical Discharge Horizontal Discharge (Rear Only) Simple Discharge Conversion
  • Slide 18
  • Optional Plenum Fan for 4-5 ton sizes
  • Slide 19
  • 19 Advanced Fan Performance ECM motor technology 40% more efficient than standard direct-drive PSC motors 10-15% more efficient than belt-drive motors Full-featured ECM Motor Variable speed-control through Potentiometer 0-10v input from BAS Value-Engineered ECM Motor Five programmed fixed speeds Up to three operational speeds (selected at commissioning)
  • Slide 20
  • 20 NDB Summary Small footprint Standard Double-wall construction Powder-coated cabinet with 500 hr. salt-spray rating Return-air Plenum accessory Standard Optional 30% Outside Air Damper Optional Economizer/Mixing Box (OA and RA dampers) 3-row HW coil option for high-efficiency boilers Integral door electrical disconnect 2 MERV 8 filters Belt-less blower for reduced maintenance and sound
  • Slide 21
  • Progress so far Released in New Magic selection software Significant progress in several markets Road Show helps demonstrate features, low sound Mostly new construction, Bid and Spec Strong spec features defended by engineers Potential New Features Based on Feedback Plenum with full economizer Electric Heat Value-engineered single-wall option Update after 2014 Launch 21
  • Slide 22
  • Coil Section Blower Section w/ FC Fan Pre-filters MERV 8/13 Slide Out Coil Section 12 rows max. Outdoor Air Basic Unit Belt-drive FC Fan Single Wall Construction 22 Return Air Supply Air Supply Air (Opt) New Rooftop AHU
  • Slide 23
  • Coil Section Blower Section w/ Plenum Fan Pre-filters MERV 8/13 Slide Out Coil Section 12 rows max. Outdoor Air Premium Unit Plenum Fan / Post Filter Double Wall Construction 23 Return Air Post Filter HEPA/MERV14 Supply Air Supply Air (Opt) New Rooftop AHU
  • Slide 24
  • Electric Heat Section Electric Heat Module 24 Supply Air Supply Air (Opt) New Rooftop AHU
  • Slide 25
  • New Direct-drive HBB 25 800, 1200, 1600, 2000 CFM Variable or Multi-speed blower
  • Slide 26
  • 26 New Website and Literature
  • Slide 27
  • 27 is investing heavily in Products Promotion Systems Tools Our Joint Commitment to follow through on our Vision Is Critically Important ! In Summary