air release valves x-294 and x-295 - irrigation...
TRANSCRIPT
Air release valves X-294 and X-295The JIMTEN air release valves permit the control of airinside of the pipelines, assuring the safety and optimumhydraulic performance.
Ventouses X-294 et X-295Les ventouses JIMTEN permettent de contrôler l´air dans lescanalisations de fluide et garantissent leur sécurité et uncomportement hydraulique optimal.
ref.sizemesure
threadfilet
4
AIR RELEASE VALVESVENTOUSESexpulsion air systemsystème d´expulsion d´air
Dimensions / Dimensions
- Air release valves X-294 (Simple effect), X-295 (Double effect).- Compact design.- 3/4”, 1”, 11/2” and 2” in NPT and BSP thread connections.- PN 16 Bar. / PN 16 Bar.- A single hydraulic locking for all the functions.- Body and lower part manufactured in Polyamide.- NBR lock Joints.- Expanded Polystyrene floater.
Characteristics / Caractéristiques générales
X-294 X-295 X-294-2” X-295-2”
CA B
26
26
103
103
201,5
201,5
1 1/2”
2”
R1
1”
1”
R2
Dimensions / Dimensions
93082
93084
93083
93085
1 1/2”
1 1/2”
2”
2”
BSP
NPT
BSP
NPT
4
4
4
4
A-2
A-2
A-2
A-2
ref.sizemesure
threadfilet
93067
93069
93068
93070
3/4”
3/4”
1”
1”
BSP
NPT
BSP
NPT
10
10
10
10
u./
A-1
A-1
A-1
A-1
nº
CA B
22
22
50,90
50,90
119
119
3/4”
1”
R1
1/4”
1/4”
R2
Dimensions / Dimensions
- Air release valves X-294 (Simple effect), X-295 (Double effect).- Compact design.- 3/4”, 1”, 11/2” and 2” in NPT and BSP thread connections.- PN 16 Bar. / PN 16 Bar.- A single hydraulic locking for all the functions.- Body and lower part manufactured in Polyamide.- NBR lock Joints.- Expanded Polystyrene floater.
R2
A
B
C
R1
X-294Air release valves Simple EffectVentouse Simple Effet
93086
93088
93087
93089
1 1/2”
1 1/2”
2”
2”
BSP
NPT
BSP
NPT
1
1
1
1
A-1
A-1
A-1
A-1
93071
93073
93072
93074
3/4”
3/4”
1”
1”
BSP
NPT
BSP
NPT
10
10
10
10
u./
A-1
A-1
A-1
A-1
nº
X-295Air release valves Simple EffectVentouse Double Effet
R2
A
B
C
R1
5
Selection, installation / Sélection, installation
Air release valves / Ventouse
The use of the air release valves in hydraulics pipelines, its necessary and is one of then most important safety elements in all the hydraulicinstallations. Its main mission is to prevent negative pressures in the network and overpressures generated by the presence of air in the pipe.
L´utilisation de ventouses dans les réseaux hydrauliques est nécessaire et constitue l´un des éléments de sécurité de toute l´installation. Sa mission principale est d´éviter des pressionsnégatives dans le réseau et des surpressions générées par la présence d´air dans le tube.
1. When a bomb stops or sudden valve it´s generate a separation between the water column and the valve, while still fluid flowingthrough the inertia of pipeline, generating a vacuum area. The same phenomenon occurs in the drain pipe.
1. Lors de l´arrêt des bombes ou fermeture soudaine des vannes il se produit une séparation entre la colonne d´eau et la vanne de fermeture. Au même moment le fluidecontinue de circuler par l´inertie du réseau, provocant après la colonne d´eau une zone de vide. Le même phénomène a lieu pendant le vidage des tuyaux.
Opened valve / Vanne ouverte Closure of valve / Fermeture de la vanne
Air release valves: the Air release valve, correctly installed, introduces airat atmospheric pressure in the pipe network, eliminating the vacuum.Ventouse: la ventouse installée correctement introduit de l air à pression atmosphériquedans le réseau en éliminant la zone de vide.
Negative pressure zone: After closing the valve, the inertia of the columnof water creates a negative pressure zone, which will be more importantin negative slopes.Zone de pression négative: Aprés la fermeture de la vanne, l´inertie de la colonned´eau génère une zone de pression negative qui sera plus importante en pentesnégatives.
2. When pipes are filling in, air expulsion must be equal to admission of water. If the air of the installation is not removed, thepipeline could collapse in the highest points, reducing the hydraulic capacity of filter elements, and causing problems of overpressureand cavitation, caused by air in the fluid.
2. Lors du remplissage des tuyaux l´expulsion de l´air doit être égale à l´admission d´eau. Si l´air n´est pas expulsé dans le réseau, le tuyaux peut être colmaté dans lespoints les plus hauts, diminuant ainsi la capacité hydraulique ou des éléments de filtration et provocant des problèmes de sur pression et de cavitation dus à la présenced´air dans le fluide.
Filling pipes / Remplissage des tuyaux
Emptying pipe / Vidage des tuyaux
Negative pressure area / Zone de pression négative
Air release valves / Ventouse
If the air it s not remove, it will be deposited inloops and points of higher altitude.Si l´air n´est pas expulsé, il va se déposer dans les boucles et points les plus hauts.
Empty pipe, when of filling it, the air will move to higher areas.Tuyau vide, dans le moment du remplissage l´air se déplacera vers les zones sipérieures.
Vacuum area / Zone de vide
Vacuum area / Zone de vide
1 2
3
6
Air release valve dimensioning:Dimension de la ventouse:
Air release valve diameter / Diamètre de ventouse
inches / pouces
mm0-50
3/4”
110-160
1 1/4
50-110
1”
160-225
2
Pipeline diameter / Diamètre de conduite
Internal operation / Fonctionnement interne
Expulsion of residual air(Only model X-295). The air release valve purgesconstantly the residual air generated in theinstallation, by expelling it even when it is underpressure.
ExpulsionWhen the pipe is being filled, theair release valve remains openexpelling all the surplus air outsidethe installation. When the pipe isfull of water the air release valvecloses tightly.
Expulsion de l´air résiduel(Uniquement le modèle X-295). La ventouse maintientde façon constante une fonction de purge de l´air résiduelgénéré dans l´installation en l´expulsant lorsqu´il estencore sous pression.
Air release valves simple effectVentouse simple effet
Air release valves double effectVentouse double effet
Air AdmissionUnder negative pressures (pipevacuum) the air release valve opensto allow the air go inside the pipe.This system avoids possibledamages in pipes and accessories.
AdmisiónSous pressions négatives (vide) laventouse s´ouvre en introduisant l´airdans le réseau et en évitant ainsi ladétérioration des tuyaux et accessoires.
Air release valves simple effectVentouse simple effet
Air release valves double effectVentouse double effet
Air release valves double effectVentouse double effet
Air release valve dimension / Dimension de la ventouse
X-294
1
X-295
2
X-294
3
X-295
4
5
X-295
3. If the pipe network suffers a breakdown, the water flowdrained could be greater than the air admitted into the network,that’s why a protection element such as an air release valvecorrectly dimensioned should be installed.
3. En cas de panne dans le réseau, le débit d´eau évacué peut être supérieur àl´air admis dans le réseau, d´où le besoin de l´installation d´une ventousecorrectement dimensionnée.
4. Close to, pumping equipments, filtration equipments or firehydrants, air bubbles can enter the pipe network, this residualair must be eliminated by installing double effect air releasevalves.
4. Lors de l´utilisation d´équipements de pompage, de filtration ou hydrants, desbulles d´air peuvent être introduites dans le réseau, cet air résiduel doit êtreéliminé à l´aide de l´installation de ventouses double effet.
ExpulsiónAu moment du remplissage du réseau,la vantouse reste ouverte expulsant toutl´excédent d´air de l´installation jusqu´àce que le réseau soit rempli d´eau et laventouse se ferme de manière étanche.
7
Performance / Rendement
Double effect / Double effet
70
60
50
40
30
20
10
0
0 5 10 15 20 25 30 35 40 45
20
10
4003002001000 500
Simple effect / Simple effetX-294
X-294
X-295
80
70
60
50
40
30
20
10
0
Expelled flow (CFM) / Débit expulsé (CFM)
0 100 20050 150 250
Diff
eren
tial p
ress
ure
(mca
)P
ress
ion
diffé
rent
ielle
(m
ca)
Expelled flow (CFM) / Débit expulsé (CFM)
Diff
eren
tial p
ress
ure
(mca
)P
ress
ion
diffé
rent
ielle
(m
ca)
Expelled flow (CFM) / Débit expulsé (CFM)
Diff
eren
tial p
ress
ure
(mca
)P
ress
ion
diffé
rent
ielle
(m
ca)
0
-5
-10
0255075100
Flow admitance (m3/h) / Débit admi (m3/h)
Diff
eren
tial p
ress
ure
(PS
I)P
ress
ion
diffé
rent
ielle
(P
SI)
0
-10
100 0200300400500
Flow admitance (m3/h)Débit admi (m3/h)
Diff
eren
tial p
ress
ure
(PS
I)P
ress
ion
diffé
rent
ielle
(P
SI)
0
-4
-8
-12
0246810
Flow admitance (m3/h) / Débit admi (m3/h)
Diff
eren
tial p
ress
ure
(PS
I)P
ress
ion
diffé
rent
ielle
(P
SI)
30
20
10
0
0 200 400100 300 500
SIMPLE EFFECT, CLOSINGFERMETURE EFFET SIMPLE
Expelled flow (CFM) / Débit expulsé (CFM)
Diff
eren
tial p
ress
ure
(mca
)P
ress
ion
diffé
rent
ielle
(m
ca)
160
120
80
40
0
0 20 40
Expelled flow (CFM)Débit expulsé (CFM)
Diff
eren
tial p
ress
ure
(mca
)P
ress
ion
diffé
rent
ielle
(m
ca)
0
-5
-10
0100200300400
SIMPLE EFFECT, CLOSINGFERMETURE EFFET SIMPLE
Flow admitance (m3/h) / Débit admi (m3/h)
Diff
eren
tial p
ress
ure
(PS
I)P
ress
ion
diffé
rent
ielle
(P
SI)
DOUBLE EFFECT, CLOSINGFERMETURE EFFET DOUBLE
3/4” - 1”
1 1/2” - 2”
3/4” - 1”