air source heat pump - solfex
TRANSCRIPT
Air Source Heat PumpProduct Guide & Price List - 2015
Contents
4 - Contacts
5 - Why Heat Pumps?
6 - Planning Design and Support
7 - Training
8 - Heat Pump Training Dates 2015
10 - Prestige Heat Pump Packs
12 - Prestige Heat Pump Pack Components
14 - Other Accessories
16 - Unvented Cylinder
18 - Pre Plumbed Cylinder
20 - Buffer Tanks
22 - AEC
24 - Case Study
26 - Samsung EHS
28 - LG Electronics
32 - Hitachi
For nearly a decade, installers have trusted SOLFEX energy systems to deliver their renewable energy products. Heat Pump systems and components are an integral part of this.
As part of the Travis Perkins PLC group of companies we offer our customers a solid, reliable distribution platform as well as heat pump expertise from a dedicated sales and
technical division.
SOLFEX energy systems can supply a range of renewable heat products and services for all applications, from domestic residential housing, utilising our renowned Prestige
Heat Pump Packages, through to a bespoke system for commercial applications such as hotels, sports & leisure facilities and manufacturing plants.
Our speciality is and always will be the integration of renewable and high efficiency products from the worlds leading manufacturers. As well as heat pumps, we also offer
market leading underfloor heating, solar thermal and solar photovoltaic products.
Our product management, technical and procurement teams operate alongside our manufacturing partners in order to provide a homogeneous approach to product
quality and service. Every component is carefully selected on its technical performance, longevity and warranty prior to being accepted within our portfolio.
Company Introduction
4
Contacts
Head Office
SOLFEX LtdEnergy ArenaUnits 3-5Charnley Fold Industrial EstateBamber BridgePrestonLancashirePR5 6PS
Tel: 01772 312 847Fax: 01772 335 277Email: [email protected]
Expert Heat Pump support
Our Heat Pump sales team are always happy to help with any queries that you may have. Whether it be a sales order or a more technical question, our staff are highly trained in all aspects of heat pumps to ensure we give you the highest quality service.
Internal Sales & Technical Team External Sales Team
*On orders before 5pm
Order Online
www.webportal-solfex.co.uk
Chris HiggsProduct Manager
Tel: 00 44 1772 317013Email: [email protected]
Ben PerrisNational Sales Manager
Tel: 07792315189Email: [email protected]
Mary ColapintoSales Office Manager
Tel: 00 44 1772 317011Email: [email protected]
Rik WhinesTechnical Sales Engineer
Tel: 00 44 1772 317007Email: [email protected]
Sean McSorleyTechnical Sales ManagerLondon & Southern EnglandTel: 07807521766Email: [email protected]
Tom BainesTechnical Support Engineer
Tel: 00 44 1772 317003Email: [email protected]
Graham FurbyTechnical Sales ManagerEastern EnglandTel: 07792478420Email: [email protected]
24 hour shopping
You can now order all of our heat pump products online. Our webshop is quick and easy to use and allows you to order at a time and place that’s convenient. All orders before 5pm are eligible for next day delivery.
• Browseourfullproductportfolio,withfulldescriptions,datasheetsandpricing
• Open24/7• Nextdaydeliveryonordersbefore
5pm• Experttechnicaladvicejustaphone
callaway
NEW! Next Day
Delivery!*
5
Why Heat Pumps?
Finally, you can control the cost of your own heatingHeat Pumps, most notably air source heat pumps, are fast becoming the most popular renewable heating source in the UK. To date, around 30,000+ MCS accredited air source heat pumps have been installed in the UK since 2009. Though heat pumps require electricity to run, the way that they utilize this electricity means that they are a very cost effective and environmentally friendly way to provide your hot water and space heating requirements all year round.Chances are, you already have a heat pump in your own home, in the form of a refrigerator. A common misconception is that a refrigerator makes things cold…. What it actually does is to take energy from inside the fridge and transports it to the back of the fridge, hence why if you touch the coil on the back of your fridge, it will be warm, whilst the inside of the fridge is cold.
If we reverse the operation, and apply it to an air source heat pump, you will find that the inside of the fridge now becomes your garden and the warmth on the back of the fridge is now the heat circulating around your pipework to your radiators / underfloor heating. The area directly in front of the heat pump will be much cooler than the rest of the garden because that energy is being transported into your property via the vapour compression cycle. Essentially, what is happening is that unusable energy from outdoors is being transformed into usable energy for indoors.
Air source heat pumps require electricity in order to power the compressor, circuit boards, circulation pumps etc.. For every 1kW of electricity used by the heat pump unit itself, it will provide around 4kW of heat. That means that 3kW of heat is being provided completely for free so you could say that a heat pump is around 400% efficient. If you compare this with a traditional gas boiler you will see that for every 1kW of energy used by the boiler, only around 90% of the fuel is used for heating. The rest is sent to the atmosphere via the flue. If you combine a heat pump with a SOLFEX PV system in order to offset some of the heat pump electricity usage, the running costs of the heat pump reduce even further and if you can also install a SOLFEX Solar Thermal and Underfloor Heating system you truly have a whole house solution.
As well as being one of the most efficient forms of space heating available, an air source heat pump installation may also attract a government subsidy in the form of the Renewable Heat Incentive. For a 4 bedroom semi-detached property this could equate to around £1000 a year in guaranteed index linked payments
*Based on an average 4 bed detached property
Heat Pump Savings
£0.00
Coal
Savings per year RHI Income per year
Gas
Electric
Oil
LPG
£700 £1,400 £2,100 £2,800
6
PU 01
FA 01
PU 02
FA 02
FA 03
+
HE 01
+
HE 02
+
HE 03
-
CO 01
-
CO 02
-
CO 03
TT01
PT01
FT01
TI01
PI01
FI01
VA 01M
VA 03
VA 02M
VA 04
VA 05
VA 11M VA 12M VA 13VA 14
VA 15VA 16
VA 07
VA 08
VA 17VA 18
AV 01
air outlet
air inlet
air flow
AV 02
M
FC01
PC01
TC01
el.signal
EV 01
PU 0
2
VA 12M
GA 01
EV 02VA 12M
FI 01
PI01
CL 01
CD 01 SE 01 FI 01
CO 01
pn.signal
DR 01
HX 01
M
EX 01
MIssing components?
- make your own! -
publish the drawing and send us the link.
Components we believe add values to our users will be incorporated into our
templates.
Tips!
- Change the insertion points of components by selecting
"Format > Snap grid" and
"Format > Snap guidelines"
from the menu.
- Right click and "Ungroup" the objects to edit, m
ove, rotate text or change
details. Regroup after change.
- Copy components between drawings with the Web ClipboardSelect component(s) above! - c
opy and
paste into the drawing!
Project ID:
Drawing no:
Rev.
Classification:
Reviewer:
Date:Sheet: S-0002
of
Submitted:
Approved for release:
Drawn: CH
Design:
Date: 10/11/14Checked:
Training Room Mechanical Layout
Description
No DateClass Rev
DWNVER
CHKDSUB
APP
VA 06
FlexiVA
07
VA 06
VA
05
VA
05
VA
06VA 02M
VA 02M
VA
05
Auto
Bypass
Radiator
Bypass Loop
PU 01
PU 01
Buffer
Tank
DHW
Tank
To Hot Water
Services
Cold Mains In
MF 01
FS 01 FM 01
VA
06
VA
06
VA
07Flexi
VA
07
VA
07
Flexi
Flexi
VA
07
VA
07
Flexi
Flexi
VA
07
VA
07
Flexi
Flexi
CodePart
VA06Gate Valve
VA02Motorised 2 Port V
alve
VA05Non Return Valve
PU01Circulation Pump
EX01Expansion Vessel
MF01Magnetic Filter
FM01Flow Meter
FS01Flow Switch
VA07Isolation Valve
Planning Design and Support
AtSOLFEXenergysystemswecanspecify,design&indemnifyyourproposedheatpumpinstallation,fromastandardsmalldomesticinstallationtoacommercialheatpumpsystem.
When specifying a heat pump system for any building, key bespoke requirements of the building need to be taken into account such as:
• ProjectReference• SiteLocation• FloorArea• AgeofBuilding• NumberofBedrooms(Ifapplicable)• DomesticHotWaterRequirement(Ifapplicable)
The above are just some of the details we would require in order to approximately specify and dimension a heat pump system.
In order to specify the system accurately, SOLFEX energy systems can assist you with the completion of the BS EN 12831 heat loss calculation in line with the requirements for RHI and MCS. We have special tools and calculators built to assist with all aspects of the heat load calculation process.
Heat Pump Engineering Support• Pre-installation&on-siteinstallersupport/consultancybyour
trainedprofessionals• Samplehydraulicandelectricallayoutsformanysystems• Indemnityofthesystemdesignandspecification• Commissioning&on-siteinstallersupportthroughoutinstallation
canbeprovided.Enquireforfurtherdetails.
Customer Service & After-sales SupportAt SOLFEX energy systems customer support & service does not end when you have purchased & installed your system. Our dedicated internal technical support team will ensure your enquiry will be dealt with professionally and in a timely manner.
Dedicated On-Site SupportFurther to our dedicated internal team, we also have a team of external technical sales engineers who can provide on-site technical support to MCS accredited installers and consultants to ensure that projects are specified and installed as trouble free and as efficiently as possible.
7
Training
SOLFEXenergysystemsprideourselvesonthesupportandcustomerserviceweoffer.Inordertoensurethatthespecificationandinstallationofyournewheatpumpisassmoothaspossible,weofferfulltrainingforourentirerangeofheatpumpsatvariouslocationsintheUK.
All training courses are divided into two very distinct parts and are always held over a single day so as to ensure that the impact on your business is kept to an absolute minimum. All training courses are delivered on live installations to make sure that your experience is as relevant as possible.
Part 1 – System Design and Unit Specification Heat Pump design and specification is very different to traditional fossil fuel heating sources. There are a number of different considerations which need to be taken into account prior to installation.
Part1oftheheatpumptrainingencompassessuchtopicsas:
• WhatisaHeatPumpandhowitfitstoaproperty• HeatPumpLocationandDrainageRequirements• OverviewofCirculationPumpSizing• HeatPumpOptimizedDomesticHotWaterCylinders• EmitterCircuitConsiderationsforRadiatorsandUnderfloorHeating• AlternativeSystemDesignincludingHybridSystems• ExplanationsofSPFandCOPefficiencies• AvailableIncentives• WhatisMCS?• CalculatingtheHeatLoadofapropertytorelevantstandards• ElectricalandMechanicalConsiderations
Part 2 – Installation and Commissioning The installation of a heat pump is very similar to that of a traditional fossil fuel boiler. The most evident difference is in the controls and commissioning of the system. If these are not treated with the utmost care, a very efficient system can quickly become inefficient.
Part2oftheheatpumptrainingencompassesthebelowtopics:
• LiveInstallationComponentOverview• FullCommissioningWalkthrough
After Sales Support SOLFEX energy systems understand that training does not begin and end in the classroom. With this in mind, we provide an unparalleled level of after sales technical support to ensure that all topics learned in the classroom can be successfully implemented in the field. As you leave the classroom you will be given two points of contact for dedicated technical support meaning that should you require assistance it will always be available.
8
Heat Pump Training Dates 2015
Preston Chertsey Preston Slough Leeds Preston Maidenhead Preston
Jan 13th 16th 27th
Feb 24th 17th 5th & 24th 26th 10th 3rd
Mar 10th 5th & 24th 26th
Apr
28th 21st 14th 7th
May 12th 12th 26th
Jun 30th 23rd 16th 9th
Jul
14th 7th 28th
Aug
25th 18th 11th 4th
Sept 15th 8th 29th
Oct 27th 20th 13th 6th
Nov 10th 10th 24th
Dec 29th 22nd 15th 8th
Note - Dates are subject to change, please contact our Heat Pump sales team for confirmation of dates
Mary ColapintoSales Office Manager
Tel: 00 44 1772 317011Email: [email protected]
Booking
Formoreinformation,ortobookyourplaceatanyoftheHeatPumpTrainingCourses,contactMaryColapinto.
9
Pres
tige
Hea
t Pu
mp
Pack
sPrestige Packs
Prestige ComponentsHeat Pump Accessories
Unvented CylindersPre Plumbed Cylinders
Buffer Tanks
10
Prestige Heat Pump Packs
All SOLFEX energy systems air source heat pump prestige packs are designed with the installer in mind. In order to ensure that installations are as simple and as straightforward as possible, many packs have been hand crafted to allow for around 95% of the components you will require on site. As we only use the highest quality components, which are engineered to compliment the heat pump they are applied to, you can be sure that ordering a SOLFEX prestige pack guarantees you a peace of mind installation.To further add to your peace of mind, many packs are delivered on a single shipping pallet and packed so as to ensure that they are safe and protected in transit.
SOLFEX energy systems has long held a deserved reputation for promoting only the worlds leading manufacturers in relation to the main equipment we supply. This reputation however does not end at main products. We have, and always will, ensure that only the most suitable and highest quality components are used to compliment our range of Heat Pumps.
11
When supplying around 95% of the equipment required by an installer on site, we have to be sure that the quality of the components will not negatively influence the installers perception of the main product, or indeed SOLFEX as a whole.
In order to ensure this confidence in our components is well placed, we only source our equipment from Europe. This ensures that we have full traceability back to manufacturer for anything as small as a single brass nipple through to something much larger like a buffer tank.Our involvement in components does not simply end at sourcing them. SOLFEX are also heavily involved in the design of many of our
components. In fact, much of the equipment you will find in our prestige air source heat pump packs can only be purchased through SOLFEX due to our continued and trusted relationship with our existing supply chain.
12
Prestige Heat Pump Pack Components
Heat Pumps
Japanese, Korean and UK manufactured heat pumps from some of the biggest brands in the world. Each manufacturer possesses equipment which fulfils a specific requirement in the UK market.
Pre Insulated Flexible HosesWhen installing a monobloc heat pump, one of the biggest issues is ensuring that valuable energy is not lost from the pipework as it exits the heat pump and enters the building. This run may be no more than a metre, but it is extremely important that only the highest quality insulation and flexible hoses are used.
Anti Vibration Feet
When mounting a heat pump on the ground, it is very important to ensure that it is sufficiently anchored and stable. Providing a separation between property and heat pump is also extremely important to ensure that customers are not adversely affected by noise.
2 Port Valves2 port valves perform a very simple function; to deny or allow flow. The beauty of our Spanish made valves is in their design. A very simple but effective motorised opening system ensures that unlike many other 2 port valves, these are flexible enough for a wide variety of heat pumps without the worry of unwanted flow related error codes.
Control Kits
In order for any of the SOLFEX supplied heat pumps to work correctly, they require a very specific set of controls. Each control kit is designed to be as straightforward to set up and commission as possible
Isolation ValvesThe means of hydraulically isolating the outdoor heat pump unit from the rest of the heating system is a task which should only be left to the highest quality isolation valves. SOLFEX full bore lever arm isolation valves ensure the absolute minimum resistance when open, and a secure leak free confidence when closed.
13
Flow Meter
No heat pump can be accurately commissioned without the use of a specific flow meter. SOLFEX flow meters not only provide an accurate way to measure the flow through the system, but they also provide a means of correctly filling the system through the integrated ¾” flush and fill ports.
Tyfocor
Propylene glycol is very important in order to guarantee the continued operation and lifespan of your air source heat pump. For the manufacturers which require glycol to be added to the system as part of their warranty conditions, SOLFEX provide only the most trusted food safe propylene glycol.
4 pole isolator switch
To protect yourself and your customers, it pays to ensure that electrical isolation is handled by a world leader in electrical switchgear. Our German manufactured isolator switches by Kraus and Naimer are among the best in the world.
Brassware
In order to ensure that small components are not the cause of negative perceptions towards the heat pump packs or SOLFEX in general, only the best Italian manufactured brassware is included in our packs. All brassware is manufactured to ensure the best possible seal.
Installation specific literature Together with around 95% of the components you require on site, we also provide comprehensive installation and commissioning instructions for a wide variety of installation types. Whilst generally, installations will be very similar, having a dedicated manual which outlines the specific wiring and controller setup can make a huge difference to an installer in terms of cost and time. All literature is backed up by our internal technical support team should you have any questions.
Magnetic Filter
Nothing will damage a heat pump’s plate heat exchanger quicker than metallic sludge present in the heating system. All systems should be power flushed prior to connection, but it only takes a few microns of metallic sludge to render a heat exchanger inefficient. SOLFEX magnetic filters are proven in the field to ensure that heat exchangers remain efficient and problem free.
Buffer Tanks
Many heat pump manufacturers now insist on the use of buffer tanks in order to ensure that the correct volume of water is available to the heat pump at all times. Where applicable, our prestige packs provide buffer tanks which are sized specifically in line with the manufacturers instructions.
take pic
14
Other Accessories
OWL is the UK’s premium brand of wireless energy monitoring and control products. The OWL team combines many years of commercial experience with an in depth knowledge of wireless hardware and cloud software development. Since their inception in 2006 they have designed and manufactured a broad range of high quality products which have become household favourites.
Specifically designed to remotely control heating systems which incorporate a Heat Pump. OWL Intuition HPW remotely controls the heating system from any internet connected device from anywhere and anytime. How does it work? Network OWL Gateway simply plugs into the home’s broadband router. This provides a secure connection to the OWL Intelligent Cloud software platform. The Network OWL Gateway automatically sends energy consumption and generation data to the cloud from the OWL Sensors and Transmitter. This can then be viewed via a clear, easy-to-use web dashboard showing live and historic data from any Internet connected computer or device and from anywhere.
Bronz-Glow are a market leading company that specialise in the field of corrosion protection for heat exchangers. This covers a large field of applications and throughout 25 years of experience, they have been able to develop new techniques that make Bronz-Glow unique.
Available Processes
• FullHeatPumpcolourchangetoanyRALcolour• Anti-corrosionprotectionforhighpollutionormarineenvironments
Features & Benefits
• Remotelycontrolyourheatingsystem• Accessheatpumpcontrolviaanyinternetconnected
device• Viewtheamountofelectricityconsumedbyyour
HeatPump• ComparetheHeatPumpenergyconsumptionwith
overallenergyconsumptioninyourproperty.
15
Flexible Hoses
When connecting from the heat pump to the property services it is always advised that a set of stainless steel EPDM lined flexible hoses are used prior to connection to rigid pipework. Our flexible hoses are manufactured in the UK specifically with air source heat pumps in mind. The bend radius of the hose is more than adequate to accommodate the installation dimensions associated with a heat pump.
Pipe Insulation
Poor insulation can considerably increase the running costs of an air source heat pump system. In order to limit these parasitic heat losses it is vitally important that high quality insulation from a trusted brand is used. SOLFEX exclusively supply HT ARMAFLEX Foamed EPDM rubber insulation in many pipe sizes and thicknesses.
Low Loss Headers
In order to ensure that there are no flow issues between the heat pumps hydraulic requirements and the emitter circuit, in many cases it is advisable to employ a low loss header. One such instance is when utilizing a heat pump on an underfloor heating circuit which requires a difference in flow and return temperatures of 10 degrees, whilst the heat pump circuit will require a 5 degree temperature difference.
Hand Held RefractometerWhen commissioning many air source heat pump systems, it will be vitally important to ensure that the concentration of glycol in the system is at the level required to provide the expected protection down to a specific ambient temperature. The only accurate way to measure glycol concentration is through the use of a refractometer. SOLFEX provide only the highest quality refractometers to ensure an accurate reading.
Through Wall Kit
Running pipework from an externally mounted air source heat pump into a property requires the pipework to run through the exterior wall. The hot pipework will be affected by cold bridging and heat loss if it is not insulated correctly. The Through Wall Kit provides both thermal insulation within the wall complete with elbow section to cover the copper connection.
Wall Mounting Brackets
These flat-packed, self assembly brackets provide a professional finish to the installation of wall mounted outdoor condensing units and air source heat pumps. The Type 2 brackets have a crossbar allowing the uprights to be spaced exactly as required, and include wall spacers to help level the unit on uneven walls.
3 Port Diverter Valve
Our Spanish manufactured 3 port diverter valves are specifically manufactured for use with heat pumps. Being a true diverter valve and not a mid position valve, there is no danger of supplying heating in the middle of summer when the hot water cylinder is being satisfied.
Filling Station
When commissioning a system, it is imperative that a high quality filling and flushing station is used (in conjunction with an appropriate sanitizer solution) in order to ensure that pipework is bacteria and contaminant free prior to final filling. Once bacteria free, a high pressure fill is required to ensure that air does not remain in the system. The Solarcheck Mobilcenter from SOLFEX is perfect for this task.
16
Unvented Cylinders
Solfexareproudtoofferacompleterangeofunventedstainlesssteelcylindersspecificallyforheatpumpapplicationsprovidingmainspressuredomestichotwater.
Utilising an already well established stainless steel unvented hot water cylinder, this product has been developed to maximise the lower temperatures available from the heat pump.
The heat exchanger is a totally new design. It consists of a multi-pass corrugated stainless steel tube in parallel to reduce the pressure loss whilst maximising the heat exchange. Many medium to large heat pumps need heat exchangers in the store that will cope with the higher flow rates associated with primary temperatures that are typically 50˚C or 60˚C.
Due to the fact that many heat pumps will not raise the stored water temperature to 60˚C, which is necessary to prevent the growth of legionella, the SOLHP range of cylinders are supplied with an immersion heater and a thermostat.
Duplex Stainless SteelThe latest high specification Duplex stainless steel resists all forms of corrosion including crevice and stress whilst its high mechanical strength gives it durability. The very latest automated welding procedures along with full post weld treatments guarantee welds that are as strong as the metal. All cylinders are factory pressure tested to a full 12 bar which is four times the normal working pressure.
Quality StandardAll SOLHP cylinders are manufactured in accordance with BS EN 12897 the specification for unvented water storage vessels. The cylinders have been tested by NSF-WRc and WRAS, and found to comply with Building Regulations G3 and Water Regulations.
In performance, it complies with the requirements of BS EN 806-1 to 5 and meets the NHBC criteria for domestic properties. Our manufacturing partner also operates a quality management system audited and accepted by the BSI in accordance with BS EN ISO 9001:2008.
Special features
• ThelatestandhighestqualityDuplexStainlessSteel
• 25yearguarantee.
• Fastreheatratefromitspurposedesignedlowresistancecoil.
• Oneofthehighestinsulationratingsonoffertoday.
• TheStainlessLiteHPSOLissuppliedwithallthenecessaryconnectionsincludingtwodrythermostatpockets.
Corrugated Stainless Steel CoilSOLHP cylinders use a high heat transfer corrugated tube heat exchanger to give a 20% faster recovery than plain tube. It is also lighter and stronger than plain tube making the vessel the lightest and easiest to handle on site.
Heat LossAll SOLHP cylinders are manufactured using the very latest HCFC free EnviroFoam insulation. This has an Ozone Depletion Potential (ODP) of zero and an industry leading Global Warming Potential (GWP) of 0.7. Tests show that the 50mm of EnviroFoam insulation injected into the case and covering both domes achieves astonishingly low levels of heat loss, which ensures it is fully compliant with 2010 Part L requirements for both new build and replacement cylinders.
25 Years GuaranteeThe 25 year guarantee underlines the confidence the manufacturer has in its own products.
17
SOLHP180 SOLHP210 SOLHP250 SOLHP300 SOLHP400SOLHP180
SLIMSOLHP210
SLIM
Capacity - Total Volume Litres 180 210 250 300 400 180 210
Dedicated Solar Volume Litres 65 75 90 105 130 - -
Standing Heat Loss Rate kWh/24h 1.48 1.7 1.85 2.04 2.82 2.01 2.23
Weight (empty) Kg 33 38 43 49 61 33 37
Weight (full) Kg 213 248 293 349 461 213 247
Pressure Regulating Valve Setting
Bar 3 3 3 3 3 3 3
Expansion Relief Valve Setting
Bar 4.75 4.75 4.75 4.75 4.75 4.75 4.75
Temperature Setting (P&T valve)
°C 95 95 95 95 95 95 95
Pressure Setting (P&T valve) Bar 6 6 6 6 6 6 6
Expansion Vessel Size (Volume)
Litres 18 24 24 35 2 x 24 18 24
Expansion Vessel initial charge pressure
Bar 3 3 3 3 3 3 3
Height mm 1305 1495 1745 1992 2030 1790 1970
Diameter mm 550 550 550 550 630 475 475
Surface Area of Solar Heater Coil
m² 0.68 0.68 0.97 0.97 1.27 - -
Solar Coil Pressure Loss�* Bar 0.191 0.191 0.241 0.241 0.31 - -
Heat Pump Coil Surface Area
m² 1.36 1.56 1.94 2.04 2.91 3.01 3.01
Heat Pump Coil Thermal Rating*
kW 24.3 26.2 27.5 34.2 47.2 32.8 31.2
Heat Pump Coil Pressure Loss*
Bar 0.048 0.054 0.06 0.019 0.027 0.018 0.018
ModelSelectionGuide
NumberofBedroomsinproperty Model
1 SOLHP180
2 SOLHP210
3 SOLHP250
4 SOLHP300
5 SOLHP400
6 SOLHP400
All cylinders are supplied with:
• Combinationinletgroupincorporatingpressurereducingvalve,strainer,checkvalve,balancecoldtakeoffpoint,expansionreliefvalveandexpansionvesselconnectionpoints.
• Potableexpansionvesselsc/wflexiblehoseandwallbracket
• Tundish
• Dualcontrolthermostatandcombinedoverheatthermostat(x2)
• Twoport(28mm)zonevalveforprimarycircuit
• Wiringjunctionboxforprimarysystem
* Measured at 15lpm primary flow rate Notes 1. All connections are supplied with compression fittings for direct connection to copper pipework
2. When selecting a model to be used with solar thermal, it is important to look at over sizing the vessel by 30% to account for reduced input from the solar thermal between around March and October
18
Pre Plumbed Cylinders
Special features
• ManufacturedintheUK
• ExceptionallyLowStandingHeatLosses
• IndustryStandard3m²HeatingCoil
• SmartAttractiveWhiteCasedUnit
• 25YearWarrantyonVessel
• Slimline(550mmdiameter)optionavailable
• Highestqualitycomponentsused
• Around80%ofcomponentsrequiredonsitepreplumbed
The Solfex Pre Plumbed Cylinder Provides all of your domestic hot water needs in a single extremely efficient packaged solution.
To create the simplest possible heat pump installation, SOLFEX energy systems, in conjunction with their UK manufacturing partner have created the SOLFEX Pre Plumbed Cylinder.
Available in a range of sizes from 180ltr through to 300ltr and diameters from 575 mm to 650 mm, the pre-plumbed cylinder is one of, if not the most versatile heat pump specific cylinder on the market. All models come complete with around 80% of the components you would require in a sealed heating and hot water system already pre plumbed to the cylinder, effectively saving around half a day’s labour for a plumbing and heating engineer.
19
PrePlumbedCylinderTechnicalSpecificationHP-PP-180SLIM HP-PP-210SLIM HP-PP-250 HP-PP-300
Height mm 1790 1970 1745 1992
Approx Diameter mm 575 575 650 650
Weight (empty) kg 46.3 50.3 56.3 71.3
Weight (full) kg 226.3 260.3 306.3 371.3
Capacity Litres 180 210 250 300
Standing losses kWhr/24hr 2.01 2.23 1.85 2.04
Surface area of Heat Pump coil m² 3 3 3 3
Cylinder Warranty 25 Years 25 Years 25 Years 25 Years
Cylinder Components & Electronics Warranty 2 years 2 years 2 years 2 years
Connections
1. Hotwaterdrawoff
2. Coldmainsin
3. Secondaryreturn*
4. Hotwaterflow
5. Centralheatingflow
6. HeatPumpreturn
7. DHWthermistorlocation
8. HeatPumpFlow
9. HotWaterReturn
10. CentralHeatingReturn
* Not present on 180ltr cylinders
Component Kit supplied seperately
• Potableexpansionvessel(s)c/wflexiblehose&wallbracket
• 2Port(22mm)Zonevalveforprimarycircuitenergycutout
• Wiringjunctionboxforprimarysystem
A. Temperature&Pressurereliefvalve
B. Autoairvent
C. 3Portdivertervalve
D. ControlsMountingPlate
E. Flowmeterwithflush&fillports
F. Tundish
G. FillingLoop
H. MagneticFilter
I. OverheatThermostat
J. CirculationPump
K. CylinderDrainoff
L. AutoBypass
M. ImmersionHeater
N. SystemDrainoff
Pre Plumbed Components
2
3
7
G
D
F
I
K
M
A
B
C
E
H
J
L
N
4
1
5
6
10
9
8
ModelSelectionGuide
NumberofBedroomsinproperty Model
1 HP-PP-180SLIM
2 HP-PP-210SLIM
3 HP-PP-250
4 HP-PP-300
Notes
1. All connections are supplied with compression fittings for direct connection to copper pipework
20
Buffer Tanks
Special features
• ManufacturedintheUK
• ExceptionallyLowStandingHeatLosses
• 9Connectionsonvesselasstandard
• SmartAttractiveWhiteCasedUnit
• 25YearWarrantyonVessel
• InspectionHatchformaintenance
SOLFEX energy systems multi connection Buffer Tanks assist in remedying many heat pump installation issues.
To increase the lifespan of key heat pump components, as well as to ensure that potential flow related issues are not applicable, SOLFEX Energy Systems in partnership with their UK based manufacturing partner are proud to offer a flexible solution to a multitude of installation types.
Many heat pump manufacturers have a specific requirement for minimum water volume in order to increase the lifespan of the units compressor. In some cases, this can be far above what would normally be present in a heating system. In this instance, a SOLFEX buffer tank can provide the much needed dedicated system volume.
As the name buffer suggests, these tanks are also extremely capable of storing energy for multiple uses. This energy may be required when the heat pump goes into defrost mode or even when it is serving domestic hot water. Every minute that a heat pump is serving domestic hot water is a minute that the heat pump is not providing central heating. A buffer tank can assist in tackling this problem.
BufferTankTechnicalSpecification
SOLMB090 SOLMB120 SOLMB210 SOLMB250 SOLMB300 SOLMB400
Capacity - Total Volume litres 90 120 210 250 300 400
Height mm 745 930 1495 1745 1992 2030
Diameter mm 550 550 550 550 550 630
Weight (empty) kg 13 18 28 32 37 51
Weight (full) kg 103 138 238 282 337 451
Standing Losses kWh/24h 0.85 1.06 1.7 1.85 2.04 2.82
Max Working Pressure bar 3.5 3.5 3.5 3.5 3.5 3.5
Connections mm 28mm x 8 35mm x 8
Thermostatic Pockets 2 (1 x top & 1 x bottom)
21
Hea
t Pum
psAEC
SamsungLG
Hitachi
22
AEC
Special features• UKDesigned,Manufactured&
Distributed
• Highestqualityconstructionwithcorrosionprotectedevaporatorcoil
• RemoteAccessasstandardmeaningnomoreblindattendancestosite.Youseewhattheheatpumpsees
• Threedifferentcolourwaystoensuretheheatpumpmatchestheproperty.100’smoreonrequest
• 7yearwarrantyfullpartsandlabourwarrantyasstandard
• Allcomponentswirebacktointernalauxiliaryboxtoensurethatinternaltoexternalcablingiskepttoanabsoluteminimum
• Prefertheexpansionvesselandcirculationpumptobelocatedoutside?Choosetheenhancedheatpumprangeforthequickestinstallation
• Preferthechoiceofwhereexpansionvesselandcirculationpumparelocated?Choosethestandardunitforfullflexibility
For many years, the UK has been at the forefront of manufacturing. However, up until now, there has been very little UK design and build representation for air source heat pumps. In 2015, Solfex Energy Systems released the AEC range of air source heat pumps. AEC or Ambient Energy Collector, does exactly what it suggests. The real beauty of this product is that it has been built from the ground up to be as simple and as easy to install as possible. Everything from remote access to all aspects of the heat pump, to on board installation of the circulation pump and expansion vessel, make the AEC range of equipment the new benchmark for air source heat pump design in the UK.
UK Manufactured
23
5 9Standard 9Enhanced
Power Supply
Phase = Single Single Single
V = 220-240v 220-240v 220-240v
Hz = 50Hz 50Hz 50Hz
Nominal ConditionAir 7ºC Flow 30/35ºC
Heating Output: kW 5.5 9 9
Electrical Input: kW 1.22 2.55 2.55
COP: 4.52 3.45 3.45
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 5 9 9
Electrical Input: kW 1.56 2.75 2.75
COP: 3.21 3.24 3.24
Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 4.5 8 8
Electrical Input: kW 1.32 3.11 3.11
COP: 3.4 2.57 2.57
Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 4.5 8 8
Electrical Input: kW 2.01 3.81 3.81
COP: 2.24 2.1 2.1
Water Side
Heat Exchanger Type: Alfa Laval Plate heat exchanger
Max Permissible Water Press. bar 3 bar 3 bar 3 bar
Nominal Water Flow Rate: L/min 15.72 25.12 25.12
Minimum Water Volume: l 20ltrs 20ltrs 20ltrs
Pressure Drop at Heat Ex: kPa0.23 Bar @ 27.2
(L/min)0.19 Bar @ 35 (L/
min)0.19 Bar @ 35 (L/
min)
Pipe Connection: inch 1" BSP male thread 1" BSP male thread 1" BSP male thread
Fan Info
Quantity: - 1
Airflow Rate: m³/min 72.6m3/min (Max)
Output Power: W 0.105 (kW)
Refrigerant Side
Compressor Type: - Hermetic twin rotary
Oil: POE
Compressor Power: kW 1.1 (kW) 2.9 (kW) 2.9 (kW)
Refrigerant Type: - R410A
Refrigerant Factory Charge: g 1.7kg 2.4kg 2.4kg
Electrical Info
Running Current: MAX, A 13A 23A 23A
Starting Current: A 3A 5A 5A
Recommended Fuse Size: A 16A 25A 25A
Sound InfoSound Pressure Level dBA 45dBA @ 1 metre 48dBA @ 1 metre 48dBA @ 1 metre
Sound Power Level dBA 54dBA 57dBA 57dBA
Dimensions: HWDH,706mm D,395mm W,980mm
H,1012mm D,395mm,W
1032mm
H,1012mm D,395mm
W,1300mm
Weight: kg 65kg 85kg 100kg
Operating RangeAmbient (A2W): °C -15°C to +35°C
Leaving Water: °C 55°C max 55°C max 55°C max
AEC Technical Data
24
Case Studies
InstallationCompany: ESTRenewablesLimited
Property Type: 4 bedroom detached Retrofit
Location: Hutton, Preston Suburbs
Heat Pump: AEC 9e
Design Temp: -2.2°C
Insulation Levels: High (High Specification Cavity Wall Fill and Loft Insulation)
Heat Load: 12kW (8kW Covered by Heat Pump)
Hybrid Heating Fuel: Oil Boiler
Solar Thermal Installed: 4 x FK250
Heat Emitter: Underfloor Heating
The detached property in Hutton, Lancashire had already benefited from the installation of Solar Thermal a couple of years previous and with continually increasing oil costs, Mr Givens decided it was time to look at alternative central heating sources. Because Mr Givens wasn’t 100% sure about completely removing his oil central heating boiler and replacing it with an air source heat pump system, the decision was made instead to utilize an AEC heat pump in conjunction with the existing oil boiler. The most cost effective way to treat this installation was to use the existing boiler to serve the domestic hot water, whilst the heat pump would serve around 80% of the heating requirements for the property. The intention is that the boiler will only ever be used for central heating when the temperature drops below around 0°C. This ensures that the lions share of the heating can be delivered from the heat pump. The high specification radiators installed were already adequately sized for the lower flow temperature available from the heat pump.
25
Case Studies
InstallationCompany: SmartohmsLimited
Property Type: 4 bedroom detached new build
Location: Ribbleton, Preston Suburbs
Heat Pump: Samsung RC090MHXEA
Design Temp: -2.2°C
Insulation Levels: Very High (Virtually Passive House)
Heat Load: 5.5kW
Previous Heating Fuel: No previous fuel. Mains Gas available
Heat Emitter: Underfloor Heating
Solar Photovoltaic Installed: 10x Kioto 225wp Black Monocrystalline Modules
Solar Thermal Installed: 2x IFK 2.1 Solar Thermal Collectors
In order to best capitalize on the opportunity available when building a brand new property, Smartohms Limited, both client and installer, decided that the knowledge and experience available from SOLFEX together with industry leading Photovoltaic Panels, Solar Thermal Panels and Air Source Heat Pump would produce the best possible integration of a multitude of technologies. With aesthetics and panel performance being extremely important, Ten Kioto 225wp Mono PV Panels with black frames and black back sheets were selected which are complemented with two IFK 2.1 in roof solar thermal collectors coupled to a twin coil heat pump and solar thermal domestic hot water cylinder.
The centrepiece of the heating system is the Samsung 9kW RC090MHXEA Air Source Heat Pump, which, coupled to a wood burning stove, via a buffer tank with integrated coil can provide all of the heating and hot water requirement for the property at even the coldest times of the year. In order to ensure that the running costs are as low as possible, the heat pump has been integrated with underfloor heating upstairs and downstairs to create a very efficient heating system.
26
Samsung EHS
Special features• Extremelyquietoperation(50db(A)
at1metre)
• InternalMIMControlKitsignificantlyreduceselectricalworksrequired
• Comprehensiveinstallationspecificliteratureprovided(Hybrid,Standaloneetc.)
• Marketleadingcalculationsoftware(builttoBSEN12831)available
• Lightweightconstructionensuringmanymountingoptions
• Flexibleinstallationethoswithabilitytoincorporatemanydifferentfuelsources
• 7yearwarrantyavailableasanadditionaloption
Samsung, as the 8th most valuable brand in the world, have a deserved reputation for innovation and quality.
While they were a relatively late comer to the air source heat pump market in 2011, what they brought with them was a solution to many of the problems that earlier manufacturers had encountered. Innovations such as commissioning information designed around a specific type of installation and an extremely lightweight chassis meant that installation and commissioning was some of the easiest ever seen from a heat pump.
The training and technical support available for the equipment is second to none and when coupled with the extremely competitive price point, ensures that the Samsung equipment is quick becoming the go to product for large scale installations.
27
RC090 RC160
Power Supply
Phase = 1 1
V = 220-240V 220-240V
Hz = 50 50
Nominal ConditionAir 7ºC Flow 30/35ºC
Heating Output: kW 9 16
Electrical Input: kW 2.09 3.81
COP: 4.3 4.2
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 8.4 15.1
Electrical Input: kW 2.51 4.58
COP: 7.54 12.28
Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 3.35 5.64
Electrical Input: kW 2.25 2.18
COP: 7.59 12.01
Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 3.86 6.08
Electrical Input: kW 1.97 1.98
COP: 1.97 1.98
Water Side
Heat Exchanger Type: Brazed Plate Heat Exchanger
Required Water Press. bar 2.8 2.8
Nominal Water Flow Rate: l/min 20 30
Minimum Water Volume: l 20 20
Pressure Drop at Heat Ex: kPa 10 15
Pipe Connection: inch 1" male 1" male
Fan Info
Quantity: - One Two
Airflow Rate: m3/min 50 100
Output Power: W 8.4 14.9
Refrigerant Side
Compressor Type: - Rotary Inverter Rotary Inverter
Oil: POE POE
Compressor Power: kW 2.51 4.6
Refrigerant Type: - R410A R410A
Refrigerant Factory Charge: g 1.4 2.2
Electrical Info
Running Current: MAX, A 17.4 30A
Starting Current: A 2 2A
Recommended Fuse Size: A 20A 32A
Sound InfoSound Pressure Level dBA 50 53
Sound Power Level dBA 66 70
Dimensions: HWD 998x940x330 1,420x940x330
Weight: kg 75 103
Operating RangeAmbient (A2W): °C -20°C to 35°C -20°C to 35°C
Leaving Water: °C 25 to 55°C 25°C to 55°C
Samsung EHS Technical Data
28
LG Electronics
The LG Therma V is designed for energy efficiency, comfort & ease of installation. LG’s inverter technology ensures the highest seasonal energy efficiency in combination with optimally designed components such as the water pump, heat exchanger and fan motor.
Moreover, the pressure control technology provides stable heating capacity at low temperature and reaches target performance without difficulties, ensuring you get heating when it’s required most.
Ease and speed of installation is obtained through factory fitted components such as A-class circulation pump, plate heat exchanger, expansion vessel & electric back-up heater. Additionally, the units come gold-fin treated as standard, ensuring protection in areas close to the sea and user-oriented functions ensure end-users comfort and confidence in use.
Special features• True“all-in-one”monobloc
• Extensivewarranty,3yearsasstandardor5yearswithLGapprovedinstallerscheme
• SimpletouseselectionprogramtoselecttherightTherma-Vforyourproject
• Weathercompensationincludedasstandardforoptimumefficiency
• Pressurecontrolreinforcesheatingperformancebyoperatinginstableconditionevenatlowambienttemperature
• Emergencyback-upheatingincludedasstandard
• Quietoperationthroughoptimisedfan
• “Gold-fin”treatedasstandardforcoastalregions&areasofhighpollution
• HighefficiencyA-classcirculationpump
29
Cost* Efficiency
Electricity cost: 0.135 £/kWh Therma V 7kW COP 4.3 (A7/W35)
Natural gas cost: 0.042 £/kWh Therma V 7kW COP 3.12 (A-7/W45)
Oil cost: 0.64 £/kWh Electrical heater COP 1
*based on EST prices 2014 Oil/Gas boiler COP 0.9
LG Electronics Air Conditioning and Energy Solutions invest heavily into research and development of their product portfolio. HVAC Equipment destined for the European market undergoes vigorous testing in LG’s Energy Lab based in Lille, France, the area chosen due to its challenging climate. The units are tested here for a minimum of a year before they are released into the market.
Many air-to-water heat pumps have been installed across the UK providing energy and financial savings for end users. Therma V is ideally suited to under floor heating systems and/or low temperature radiators as well as heating domestic hot water. The below graph demonstrates the cost saving advantages over traditional heating systems.
Comparison of Energy Cost per 1kWh of Thermal Energy
0.15
£/kWh
0.10
0.05
0.00Gas Boiler
48% lower running cost @ A7/W35
36% lower running cost @ A7/W35
Oil Boiler Electrical Heating
Domestic Multi Residential Industrial
Leisure
0.64
0.135
0.0420.0430.031
30
3kW 5kW 7kW 9kW 12kW 14kW 16kW 12kW 14kW 16kW
HM031M.U42 HM051M.U42 HM071M.U42 HM091M.U42 HM121M.U32 HM141M.U32 HM161M.U32 HM123M.U32 HM143M.U32 HM163M.U32
Power Supply
Phase = 1 1 1 1 1 1 1 3 3 3
V = 220-240 220-240 220-240 220-240 220-240 220-240 220-240 380-415 380-415 380-415
Hz = 50 50 50 50 50 50 50 50 50 50
Nominal ConditionAir 7ºC Flow 30/35ºC
Heating Output: kW 3 4.99 7 9 12 14 16 12 14 16
Electrical Input: kW 0.73 1.13 1.63 2.2 2.67 3.15 3.81 2.67 3.15 3.81
COP: 4.1 4.4 4.3 4.1 4.49 4.44 4.2 4.49 4.44 4.2
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 2.75 4.58 6.41 8.25 11 12.83 14.6 11.28 13.16 15.41
Electrical Input: kW 0.85 1.33 1.9 2.44 3.18 3.8 4.45 3.31 3.92 4.62
COP: 3.24 3.44 3.37 3.38 3.46 3.38 3.28 3.41 3.36 3.34
Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 2.45 4.07 5.71 7.34 9.8 9.8 13.01 9.82 11.41 13.26
Electrical Input: kW 0.95 1.48 2.12 2.72 3.55 3.55 4.93 3.56 4.22 5.29
COP: 2.58 2.75 2.69 2.70 2.76 2.76 2.64 2.76 2.70 2.51
Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 2.17 3.62 3.62 6.51 8.73 10.31 11.48 8.92 10.38 12.13
Electrical Input: kW 1.04 1.62 1.62 2.96 4.02 4.7 5.16 4.11 4.77 5.65
COP: 2.09 2.23 2.23 2.20 2.17 2.19 2.22 2.17 2.18 2.15
Water Side
Heat Exchanger Type: Brazed plate HEX
Max Permissible Water Press. Bar 3
Nominal Water Flow Rate: l/min 8.6 14.3 20.1 25.8 34.4 40.1 45.9 34.4 40.1 45.9
Minimum Water Volume: l 20 20
Pressure Drop at Heat Ex: kPa 8.25 10.18 11.54 11.71 14.5 16.2 18.52 14.5 16.2 18.52
Pipe Connection: Inch 1" 1”
Fan Info
Quantity: - 1 1 2
Airflow Rate: m3/min 32 50 60 60 60 x 2
Output Power: W 124 124 124 x2
Refrigerant Side
Compressor Type: - Hermetic, Brushless DC motor Hermetic, Brushless DC motor
Oil: FVC68D FVC68D
Compressor Power: kW 1.5 2.1 2.1 2.1 4
Refrigerant Type: - R410A R410A
Refrigerant Factory Charge: g 750 1200 1450 1600 2200
Electrical Info
Running Current: MAX, A 10 13 14 15 25 11
Starting Current: A 2 2
Recommended Fuse Size: A 20 20 20 20 32 20
Sound InfoSound Pressure Level dBA 47 51 52 52 53
Sound Power Level dBA 55 63 65 65 67
Dimensions: HWD 834x950x330 907x1239x390 907x1239x390 1450x1239x390
Weight: kg 61 97 98 99 141
Operating RangeAmbient (A2W): °C -20 ~ 30 -20 ~ 35 -20 ~ 35
Leaving Water: °C 20 ~ 57 15 ~ 57 15 ~ 57
LG Electronics Technical Data
31
3kW 5kW 7kW 9kW 12kW 14kW 16kW 12kW 14kW 16kW
HM031M.U42 HM051M.U42 HM071M.U42 HM091M.U42 HM121M.U32 HM141M.U32 HM161M.U32 HM123M.U32 HM143M.U32 HM163M.U32
Power Supply
Phase = 1 1 1 1 1 1 1 3 3 3
V = 220-240 220-240 220-240 220-240 220-240 220-240 220-240 380-415 380-415 380-415
Hz = 50 50 50 50 50 50 50 50 50 50
Nominal ConditionAir 7ºC Flow 30/35ºC
Heating Output: kW 3 4.99 7 9 12 14 16 12 14 16
Electrical Input: kW 0.73 1.13 1.63 2.2 2.67 3.15 3.81 2.67 3.15 3.81
COP: 4.1 4.4 4.3 4.1 4.49 4.44 4.2 4.49 4.44 4.2
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 2.75 4.58 6.41 8.25 11 12.83 14.6 11.28 13.16 15.41
Electrical Input: kW 0.85 1.33 1.9 2.44 3.18 3.8 4.45 3.31 3.92 4.62
COP: 3.24 3.44 3.37 3.38 3.46 3.38 3.28 3.41 3.36 3.34
Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 2.45 4.07 5.71 7.34 9.8 9.8 13.01 9.82 11.41 13.26
Electrical Input: kW 0.95 1.48 2.12 2.72 3.55 3.55 4.93 3.56 4.22 5.29
COP: 2.58 2.75 2.69 2.70 2.76 2.76 2.64 2.76 2.70 2.51
Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 2.17 3.62 3.62 6.51 8.73 10.31 11.48 8.92 10.38 12.13
Electrical Input: kW 1.04 1.62 1.62 2.96 4.02 4.7 5.16 4.11 4.77 5.65
COP: 2.09 2.23 2.23 2.20 2.17 2.19 2.22 2.17 2.18 2.15
Water Side
Heat Exchanger Type: Brazed plate HEX
Max Permissible Water Press. Bar 3
Nominal Water Flow Rate: l/min 8.6 14.3 20.1 25.8 34.4 40.1 45.9 34.4 40.1 45.9
Minimum Water Volume: l 20 20
Pressure Drop at Heat Ex: kPa 8.25 10.18 11.54 11.71 14.5 16.2 18.52 14.5 16.2 18.52
Pipe Connection: Inch 1" 1”
Fan Info
Quantity: - 1 1 2
Airflow Rate: m3/min 32 50 60 60 60 x 2
Output Power: W 124 124 124 x2
Refrigerant Side
Compressor Type: - Hermetic, Brushless DC motor Hermetic, Brushless DC motor
Oil: FVC68D FVC68D
Compressor Power: kW 1.5 2.1 2.1 2.1 4
Refrigerant Type: - R410A R410A
Refrigerant Factory Charge: g 750 1200 1450 1600 2200
Electrical Info
Running Current: MAX, A 10 13 14 15 25 11
Starting Current: A 2 2
Recommended Fuse Size: A 20 20 20 20 32 20
Sound InfoSound Pressure Level dBA 47 51 52 52 53
Sound Power Level dBA 55 63 65 65 67
Dimensions: HWD 834x950x330 907x1239x390 907x1239x390 1450x1239x390
Weight: kg 61 97 98 99 141
Operating RangeAmbient (A2W): °C -20 ~ 30 -20 ~ 35 -20 ~ 35
Leaving Water: °C 20 ~ 57 15 ~ 57 15 ~ 57
32
Hitachi
Hitachi are well known for developing well-engineered products across the world. The air to water heat pump range is no exception. The range consists of monobloc (Yutaki-M), split (Yutaki-S) and high temperature (Yutaki-S80) units with outputs from 5kW to 24kW and exceptional performance characteristics with the energy efficiency of the units ranging from 400% to 500%*.
Hitachi can provide a heating and hot water solution to most properties in the UK whether it is for a small apartment or terrace house, larger detached houses or small commercial premises. The Yutaki range from Hitachi can save approximately 50% on fuel bills when compared to oil and LPG boilers.
*Based on CoP at 7/35 and in line with BS EN 14511
Special features• Vastrangeofproductoptionstoinclude:
5kWto24kWYutaki-S 7.5kWto14kWYutaki-M 10kW,12,kWand14kWYutaki-S80 (hightemperature)
• Industryleadingefficiencies–CoPof7kWYutaki-Mmodelis4.42(@A7/W35)
• Lowstartingcurrentonstart-up–Only1Amp
• Waterflowtemperaturerangefrom55°C,60°Cand80°Cdependingonsolutionrequired
• HitachiDChighpressurescrollcompressor
• Allunitsareinverterdriven–Heatpumpmodulatestheoutputtomatchheatloadofpropertythusmaximisingefficiency
• EnergyefficientonandoffperiodsutilisingEconomy7andEconomy10tariffs
• 5yearHitachiwarranty,asstandard
• Operationdownto-20°C
33
InstallationCompany: ESTRenewablesLimited
Property Type: 4 bedroom detached new build
Location: Buckshaw Village, Preston
Heat Pump: Hitachi RHUE3.0AVHN1
Design Temp: -2.2°C
Insulation Levels: High (New build insulation levels)
Heat Load: 6.5kW
Previous Heating Fuel: None
Solar Photovoltaics Installed: 16 x 250wp Enhance Photovoltaic P60M Black Modules
Case Study
When Mrs O’Donnell was designing her new property, she decided that the perfect compliment to the PV system that was to be installed on her property would be a heat pump.
However, because of the lack of garden space, ground source was immediately removed from the equation. This left an air source heat pump as the most viable piece of equipment to install.
Provision had already been made to ensure that the radiators installed in the property were much larger than would be traditionally installed. This ensured that the heat pump installation would be able to run at a comfortable 45°C even at the coldest points of the year, without flow temperature back up from another heating source.
Whilst financial incentives were not the driving force behind looking at renewable heating, the renewable heat incentive payments were a welcome bonus. At the present time, without the benefit of inflationary percentages, the air source heat pump system will benefit Mrs O’Donnell by £670.00 per annum. Based upon fuel savings and RHI payments on the air source heat pump alone, the payback will equate to around 10 years which has far exceeded the customers expectations.
34
RHUE3.0AVHN1 RHUE6.0AVHNRAS4HVRNME-AFRWH-4.0FSVNFE
Power Supply
Phase = Single phase
V = 230
Hz = 50
Nominal ConditionAir 7ºC Flow 30/35ºC
Heating Output: kW 7.5 14 10
Electrical Input: kW 1.69 3.25 2.29
COP: 4.43 4.31 4.36
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 7.1 13.3 10
Electrical Input: kW 2.13 3.97 2.90
COP: 3.34 3.35 3.45
Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 6.5 9.3 7.6
Electrical Input: kW 2.71 3.58 3.22
COP: 2.4 2.6 2.36
Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 6.2 9 10
Electrical Input: kW 3.08 4.07 4.35
COP: 2.01 2.21 2.3
Water Side
Heat Exchanger Type: Brazed Plate
Max Permissible Water Press. Bar 1.0 3.6
Nominal Water Flow Rate: l/min 1.29 2.41 1.7
Minimum Water Volume: l 80 156 40
Pressure Drop at Heat Ex: kPa 6.8 12.0
Pipe Connection: Inch Flexible pipe (G 1" male)
Fan Info
Quantity: - 1 2 2
Airflow Rate: m³/min 68 100 80
Output Power: W 138 70+70
Refrigerant Side
Compressor Type: - Hermetic Scroll
Oil: FVC68D
Compressor Power: kW 1.38 2.5 3.0
Refrigerant Type: - R410A R410A & R134a
Refrigerant Factory Charge: kg 2.6kg 4.2kg3.9kg (RAS) 2.5kg (RWH)
Electrical Info
Running Current: MAX, A 7.5 17.6Outdoor = 9.2 Indoor = 12.5
Starting Current: A 2
Recommended Fuse Size: A 32 32Outdoor = 20Indoor = 32
Sound InfoSound Pressure Level dBA 49 52 46
Sound Power Level dBA 68 68 65
Dimensions: HWD 800 x 1250 x 440 1480 x 1250 x 444 ->
Weight: kg 110 159RAS = 107kg, RWH = 157kg
Operating RangeAmbient (A2W): °C -20°C to +35
Leaving Water: °C 20 ~ 60 20 ~ 55 20 ~ 80
Hitachi Technical Data
35
RAS5HVRNME-AFRWH-5.0FSVNFE
RAS6HVRNME-AFRWH-6.0FSVNFE
Power Supply
Phase = Single Phase
V = 230
Hz = 50
Nominal ConditionAir 7ºC Flow 30/35ºC
Heating Output: kW 12 14
Electrical Input: kW 2.81 3.46
COP: 4.27 4.05
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 12 14
Electrical Input: kW 3.51 4.22
COP: 3.42 3.32
Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 9.0 9.4
Electrical Input: kW 3.88 4.10
COP: 2.32 2.29
Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 12 14
Electrical Input: kW 5.22 6.22
COP: 2.3 2.25
Water Side
Heat Exchanger Type: Brazed Plate
Max Permissible Water Press. bar 3.6
Nominal Water Flow Rate: l/min 2.1 2.4
Minimum Water Volume: l 50 50
Pressure Drop at Heat Ex: kPa 12.0
Pipe Connection: inch Flexible pipe (G 1" male)
Fan Info
Quantity: - 2 2
Airflow Rate: m³/min 90 100
Output Power: W 70+70
Refrigerant Side
Compressor Type: - Hermetic Scroll
Oil: FVC68D
Compressor Power: kW 3.0
Refrigerant Type: - R410A & R134a
Refrigerant Factory Charge: g 4.0kg (RAS) 2.5kg (RWH) 4.0kg (RAS) 2.5kg (RWH)
Electrical Info
Running Current: MAX, AOutdoor = 11.6 Indoor = 12.7
Outdoor = 14.5 Indoor = 14.7
Starting Current: A 2
Recommended Fuse Size: AOutdoor = 25 Indoor = 32
Outdoor = 25Indoor = 32
Sound InfoSound Pressure Level dBA 48 48
Sound Power Level dBA 67 67
Dimensions: HWDRAS = 1380mm x 950mm x 370mm , RWH = 706mm x 595mm x 695mm
Weight: kgRAS = 108kg, RWH = 162kg
RAS = 108kg, RWH = 162kg
Operating RangeAmbient (A2W): °C -20°C to +35
Leaving Water: °C 20 ~ 80
36
Pric
e Li
st38 - AEC Prestige Packs
40 - AEC Components
43 - Samsung Prestige Packs
47 - Hitachi Prestige Packs
49 - Hitachi Components
50 - Hitachi Components
53 - LG Prestige Packs
57 - LG Components
66 - Heat Pump Accessories
70 - Pre Plumbed Cylinders
71 - Unvented Cylinders
72 - Open Vented Cylinders
73 - Direct Stainless Steel Buffers
74 - Indirect Stainless Steel Buffers
75 - Multi-Tapping Buffers
37
AEC Prestige PacksDescription Part Code List PriceAECAEC5PRESTIGEAIRSOURCEHEATPUMPPACK £4,044.97
Carbon GreySolfex AEC-PHPK-001CG
AEC5 monobloc heat pump c/w controls CPS 955979Anti Vibration Feet PTS SOLAECPHPK1CInsulated Flexible Hose Set TP 955979Isolation Valves Military Green2 Port Valves Solfex AEC-PHPK-001OGGlycol CPS 761910Flow Meter with Filling / Flushing Valve PTS SOLAECPHPK1GIn-Line Magnetic Filter TP 761910Various Brassware Arctic White4-Pole Isolator Switch Solfex AEC-PHPK-001WHNeostat Room Thermostat CPS 955978
PTS SOLAECPHPK1WTP 955978
AEC5–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Carbon GreyCorrosion protection when utilized in aggressive environments
Solfex AEC-CBCP-5CGCPS 761887
Coastal or high pollution applications PTS SOLAECBCP5CGTP 761887
5 Year Anti-Corrosion Warranty Military GreenSolfex AEC-CBCP-5OGCPS 955957PTS SOLAECBCP5OGTP 955957
Arctic WhiteSolfex AEC-CBCP-5WHCPS 955956PTS SOLAECBCP5WHTP 955956
AEC5–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection. Solfex AEC-CS-5Colours available conform to RAL colour matching system. CPS 761892Please contact Solfex Heat Pump Sales for further information. PTS SOLAECCS5
TP 761892
AEC9PRESTIGEAIRSOURCEHEATPUMPPACK £4,565.81Carbon Grey
Solfex AEC-PHPK-002CGAEC9 monobloc heat pump c/w controls CPS 761911Anti Vibration Feet PTS SOLAECPHPK2CInsulated Flexible Hose Set TP 761911Isolation Valves Military Green2 Port Valves Solfex AEC-PHPK-002OGGlycol CPS 955981Flow Meter with Filling / Flushing Valve PTS SOLAECPHPK2GIn-Line Magnetic Filter TP 955981Various Brassware Arctic White4-Pole Isolator Switch Solfex AEC-PHPK-002WHNeostat Room Thermostat CPS 955980
PTS SOLAECPHPK2WTP 955980
38
AEC Prestige PacksDescription Part Code List PriceAEC
AEC9–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Carbon GreyCorrosion protection when utilized in aggressive environments
Solfex AEC-CBCP-9CGCPS 761889
Coastal or high pollution applications PTS SOLAECBCP9CGTP 761889
5 Year Anti-Corrosion Warranty Military GreenSolfex AEC-CBCP-9OGCPS 955959PTS SOLAECBCP9OGTP 955959
Arctic WhiteSolfex AEC-CBCP-9WHCPS 761888PTS SOLAECBCP9WHTP 761888
AEC9–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection. Solfex AEC-CS-9Colours available conform to RAL colour matching system. CPS 955963Please contact Solfex Heat Pump Sales for further information. PTS SOLAECCS9
TP 955963
AEC9ENHANCEDPRESTIGEAIRSOURCEHEATPUMPPACK
£4,982.47
Carbon GreySolfex AEC-PHPK-003CG
AEC9e monobloc heat pump c/w controls CPS 955982Anti Vibration Feet PTS SOLAECPHPK3CInsulated Flexible Hose Set TP 955982Isolation Valves Military Green2 Port Valves Solfex AEC-PHPK-003OGGlycol CPS 761913Flow Meter with Filling / Flushing Valve PTS SOLAECPHPK3GIn-Line Magnetic Filter TP 761913Various Brassware Arctic White4-Pole Isolator Switch Solfex AEC-PHPK-003WHNeostat Room Thermostat CPS 761912
PTS SOLAECPHPK3WTP 761912
AEC9ENHANCED–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Carbon GreyCorrosion protection when utilized in aggressive environments
Solfex AEC-CBCP-9eGCPS 761891
Coastal or high pollution applications PTS SOLAECBCP9eGTP 761891
5 Year Anti-Corrosion Warranty Military GreenSolfex AEC-CBCP-9eOGCPS 955961PTS SOLAECBCP9eOGTP 955961
Arctic WhiteSolfex AEC-CBCP-9eWCPS 761890PTS SOLAECBCP9eWTP 761890
39
Description Part Code List PriceAEC
AEC9ENHANCED–HEATPUMPCASECOLOURSELECTOR
£309.83
Can be utilized with or without corrosion protection. Solfex AEC-CS-9eColours available conform to RAL colour matching system. CPS 761895Please contact Solfex Heat Pump Sales for further information. PTS SOLAECCS9e
TP 761895
AMBIENTENERGYCOLLECTOR-5KW £3,438.54Carbon Grey
Power Supply Phase = Single Solfex AEC-5CGV = 220-240v CPS 955941Hz = 50Hz PTS SOLAEC5CG
Nominal Condition
Heating Output: kW 5.5 TP 955941
Air 7ºC Flow 35ºC
Electrical Input: kW 1.22 Military GreenCOP: 4.52 Solfex AEC-5OG
Performance Heating Output: kW 5 CPS 761873Air 7ºC Flow 45ºC
Electrical Input: kW 1.56 PTS SOLAEC5OGCOP: 3.21 TP 761873
Performance Heating Output: kW 4.5Air -7ºC Flow 35ºC
Electrical Input: kW 1.32 Arctic WhiteCOP: 3.4 Solfex AEC-5WH
Performance Heating Output: kW 4.5 CPS 955940Air -7ºC Flow 45ºC
Electrical Input: kW 2.01 PTS SOLAEC5WHCOP: 2.24 TP 955940
Water Side Heat Exchanger Type:
Alfa Laval Plate heat exchanger
Max Permissible Water Press.
bar 3
Nominal Water Flow Rate:
l/min 15.72
Minimum Water Volume:
l 20
Pressure Drop at Heat Ex:
- 0.23 Bar @ 2.72 (L/min)
Pipe Connection: inch 1” BSP male thread
Fan Info Quantity: - 1Airflow Rate: m3/min 72.6Output Power: W 0.105
Refrigerant Side Compressor Type:
- Hermetic twin rotary
Oil: POECompressor Power:
kW 1.1
Refrigerant Type: - R410ARefrigerant Factory Charge:
kg 1.7
Electrical Info Running Current: A 13Starting Current: A 3Recommended Fuse Size:
A 16
Sound Info Sound Pressure Level
- 45dBA @ 1 metre
Sound Power Level
dBA 54
Dimensions: HWD(mm)
706, 395, 980
Weight: kg 65kgOperating Range Ambient (A2W): °C -15 to +35
Leaving Water: °C max 55
AEC Components
40
Description Part Code List PriceAEC
AMBIENTENERGYCOLLECTOR-9KW £3,959.38Carbon Grey
Power Supply Phase = Single Solfex AEC-9CGV = 220-240v CPS 955944Hz = 50Hz PTS SOLAEC9CG
Nominal Condition
Heating Output: kW 9 TP 955944
Air 7ºC Flow 35ºC
Electrical Input: kW 2.55 Military GreenCOP: 3.45 Solfex AEC-9OG
Performance Heating Output: kW 9 CPS 761875Air 7ºC Flow 45ºC
Electrical Input: kW 2.75 PTS SOLAEC9OGCOP: 3.24 TP 761875
Performance Heating Output: kW 8Air -7ºC Flow 35ºC
Electrical Input: kW 3.11 Arctic WhiteCOP: 2.57 Solfex AEC-9WH
Performance Heating Output: kW 8 CPS 955943Air -7ºC Flow 45ºC
Electrical Input: kW 3.81 PTS SOLAEC9WHCOP: 2.1 TP 955943
Water Side Heat Exchanger Type:
Alfa Laval Plate heat exchanger
Max Permissible Water Press.
bar 3
Nominal Water Flow Rate:
l/min 25.12
Minimum Water Volume:
l 20
Pressure Drop at Heat Ex:
- 0.19 Bar @ 35 (L/min)
Pipe Connection: inch 1” BSP male thread
Fan Info Quantity: - 1Airflow Rate: m3/min 72.6Output Power: kW 0.105
Refrigerant Side Compressor Type:
- Hermetic twin rotary
Oil: POECompressor Power:
kW 2.9
Refrigerant Type: - R410ARefrigerant Factory Charge:
kg 2.4
Electrical Info Running Current: A 23Starting Current: A 5Recommended Fuse Size:
A 25
Sound Info Sound Pressure Level
- 48dBA @ 1 metre
Sound Power Level
dBA 57
Dimensions: HWD (mm)
1012, 395, 1032
Weight: kg 85kgOperating Range Ambient (A2W): °C -15 to +35
Leaving Water: °C max 55
AEC Components
41
Description Part Code List PriceAECAMBIENTENERGYCOLLECTOR-9KWENHANCED
Carbon Grey £4,376.04Power Supply Phase = Single Solfex AEC-9eCG
V = 220-240v CPS 955946Hz = 50Hz PTS SOLAEC9eCG
Nominal Condition
Heating Output: kW 9 TP 955946
Air 7ºC Flow 35ºC
Electrical Input: kW 2.55COP: 3.45 Military Green
Performance Heating Output: kW 9 Solfex AEC-9eOGAir 7ºC Flow 45ºC
Electrical Input: kW 2.75 CPS 955949COP: 3.24 PTS SOLAEC9eOG
Performance Heating Output: kW 8 TP 955949Air -7ºC Flow 35ºC
Electrical Input: kW 3.11COP: 2.57 Arctic White
Performance Heating Output: kW 8 Solfex AEC-9eWHAir -7ºC Flow 45ºC
Electrical Input: kW 3.81 CPS 761876COP: 2.1 PTS SOLAEC9eWH
Water Side Heat Exchanger Type:
Alfa Laval Plate heat exchanger
TP 761876
Max Permissible Water Press.
bar 3
Nominal Water Flow Rate:
l/min 25.12
Minimum Water Volume:
l 20
Pressure Drop at Heat Ex:
- 0.19 Bar @ 35 (L/min)
Pipe Connection: inch 1” BSP male thread
Fan Info Quantity: - 1Airflow Rate: m3/min 72.6Output Power: kW 0.105
Refrigerant Side Compressor Type:
- Hermetic twin rotary
Oil: POECompressor Power:
kW 2.9
Refrigerant Type: - R410ARefrigerant Factory Charge:
kg 2.4
Electrical Info Running Current: A 23Starting Current: A 5Recommended Fuse Size:
A 25
Sound Info Sound Pressure Level
48dBA @ 1 metre
Sound Power Level
dBA 57
Dimensions: HWD (mm)
1012, 395,1300
Weight: kg 100Operating Range Ambient (A2W): - -15°C to +35°C
Leaving Water: °C max 55
AEC Components
42
Samsung Prestige PacksDescription Part Code List PriceSamsung
SAMSUNGEHS9kWPRESTIGEAIRSOURCEHEATPUMPPACK
£2,871.55
SAMSUNG EHS HP-RC090MHXEA 9KW HEAT PUMP Solfex SAM-PHPK-001Control Kit (HP-MIM-E03A) CPS 761896Anti Vibration Feet PTS SOLSAMPHPK01Insulated Flexible Hose Set TP 761896Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
SAMSUNGEHS9kWPRESTIGEAIRSOURCEHEATPUMPPACK+90LBUFFERTANK
£3,347.24
Solfex SAM-PHPK-001AYou will require a SOLMB090 buffer tank if the flow rate of your installation will not achieve 20lpm (RC090) or 30lpm (RC160)
CPS 955966
The tank will also be required if the overall system volume is less than 20ltrs
PTS SOLSAMPHPK1A
When utilizing a buffer tank additional Glycol will be required. Please contact Solfex HP Technical prior to order for advice if required
TP 955966
SAMSUNGEHSWARRANTYEXTENSION–9kW £237.68Total parts and labour allowance warranty period of 7 years Solfex HP-WARR-EXT-9To be eligible the warranty extension must be purchased CPS 908495at time of heat pump order PTS SOLHPWAR709
TP 908495
HP-RC090MHXEA–CASEBASEANDCOILCORROSIONPROTECTION
£427.35
Corrosion protection when utilized in aggressive environments
SolfexSAM-CBCP-9KW
Coastal or high pollution applications CPS 7618845 Year Anti-Corrosion Warranty PTS SOLSACBC9KW
TP 761884
HP-RC090MHXEA–HEATPUMPCASECOLOURSELECTOR
£309.83
Can be utilized with or without corrosion protection. Solfex SAM-CS-9KWColours available conform to RAL colour matching system. CPS 955955Please contact Solfex Heat Pump Sales for further PTS SOLSAMCS9KWinformation. TP 955955
SAMSUNGEHS16kWPRESTIGEAIRSOURCEHEATPUMPPACK
£4,172.76
SAMSUNG EHS HP-RC160MHXEA 16KW HEAT PUMP Solfex SAM-PHPK-002Control Kit (HP-MIM-E03A) CPS 761897Anti Vibration Feet PTS SOLSAMPHPK02Flexible Hose Set TP 761897Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
43
Samsung Prestige Packs
SAMSUNGEHSHEATPUMPCONTROLKIT £427.63Power Supply Ø = 1 Solfex HP-MIM-E03A
V = 220-240 CPS 908494Hz = 50 PTS HPMIME03A
Weight Net:3.5kg TP 908494Gross:5.7kg
Dimensions Net:
290 x 342 x 110mm (W x H x D)
Gross:
330 x 430 x 170mm (W x H x D)
External Input/Output Booster Heater:
AC 230V (Max 20A)
Back up Heater / Boiler:
AC 230V (Max 0.5A)
Water Pump:AC 230V (Max 2A)2 way or 3 way
Valve:AC 230V (Max 0.5A / 120W)
Room Thermostat:AC 230V (Max 10mA)
Solar Pump:AC 230V (Max 10mA)
Description Part Code List PriceSamsungSAMSUNGEHS16kWPRESTIGEAIRSOURCEHEATPUMPPACK+90LBUFFERTANK
£4,893.11
Solfex SAM-PHPK-002AYou will require a SOLMB090 buffer tank if the flow rate of your installation will not achieve 20lpm (RC090) or 30lpm (RC160)
CPS 761898
The tank will also be required if the overall system volume is less than 20ltrs
PTS SOLSAMPHPK2A
When utilizing a buffer tank additional Glycol will be required. Please contact Solfex HP Technical prior to order for advice if required
TP 761898
SAMSUNGEHSWARRANTYEXTENSION–16kW £374.35Total parts and labour allowance warranty period of 7 years Solfex HP-WARR-EXT-16To be eligible the warranty extension must be purchased CPS 132220at time of heat pump order PTS SOLHPWAR716
TP 132220
HP-RC160MHXEA–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Corrosion protection when utilized in aggressive environments
SolfexSAM-CBCP-16KW
Coastal or high pollution applications CPS 9559545 Year Anti-Corrosion Warranty PTS SOLSACBC16KW
TP 955954
HP-RC160MHXEA–HEATPUMPCASECOLOURSELECTOR
£395.30
Can be utilized with or without corrosion protection. Solfex SAM-CS-16KWColours available conform to RAL colour matching system. CPS 956334Please contact Solfex Heat Pump Sales for further information.
PTSSOLSAMCS6KW
TP 956334
44
Description Part Code List PriceSamsung
SAMSUNGEHSMONOBLOC9KWHEATPUMP £2,047.50Solfex HP-RC090MHXEA
Power Supply Phase =1 CPS 132219V =220-240V PTS HPRC090MHXEA
Hz =50 TP 132219Nominal Condition
²Cooling:10,000W / 34,100 Btu/h
Air 7ºC Flow 30/35ºC
Heating Output:9kWElectrical Input:2.09kW
COP:4.3PerformanceAir 7ºC Flow 40/45ºC
²EER (Cooling):3.5Heating Output:8.4kWElectrical Input:2.51kW
COP:3.35PerformanceAir -7ºC Flow 30/35ºC
³Heating:2,510WHeating Output:7.54kWElectrical Input:3.35kW
COP:2.25PerformanceAir -7ºC Flow 40/45ºC
ESEER:4.26 - Water Out at 7ºC
Heating Output:7.59kWElectrical Input:3.86kW
COP:1.97kWWater Side Heat Exchanger
Type:Brazed Plate Heat Exchanger
Required Water Press.
2.8 bar
Nominal Water Flow Rate:
20lpm
Minimum Water Volume:
20ltrs
Pressure Drop at Heat Ex:
10kPa
Pipe Connection:1" maleFan Info Quantity:One
Airflow Rate:50m³/minOutput Power:8.4kW
Refrigerant Side Compressor Type:Rotary InverterOil:POE
Compressor Power:
2.51kW
Refrigerant Type:R410ARefrigerant Factory
Charge:1.4kg
Electrical Info Max Running Current:
17.4A
Starting Current: 2ARecommended Fuse Size:
20A
Sound Info Sound Pressure Level
50dB(A)
Sound Power Level66dB(A)Net Dimensions HWD (mm) 998 x 940 x 330Net Weight: 75kgOperating Range Ambient (A2W): -20°C to 35°C
Leaving Water: 25 to 55°C
Samsung Components
45
Description Part Code List PriceSamsungSAMSUNGEHSMONOBLOC16KWHEATPUMP £3,321.45Power Supply Phase =1 Solfex HP-RC160MHXEA
V =220-240V CPS 714426Hz =50 PTS HPRC160MHXEA
Nominal Condition
¹Heating:16,000W / 54,600 Btu/h
TP 714426
Air 7ºC Flow 30/35ºC
Heating Output:16kWElectrical Input:3.81kW
COP:4.2PerformanceAir 7ºC Flow 40/45ºC
¹COP (Heating):4.2Heating Output:15.1kWElectrical Input:4.58kW
COP:3.3PerformanceAir -7ºC Flow 30/35ºC
Cooling:13,100W / 44,700 Btu/h
Heating Output:12.28kWElectrical Input:5.64kW
COP:2.18PerformanceAir -7ºC Flow 40/45ºC
EER (Cooling):2.45Heating Output:12.01kWElectrical Input:6.08kW
COP:1.98Water Side Heat Exchanger
Type:Required Water
Press.2.8 bar
Nominal Water Flow Rate:
30lpm
Minimum Water Volume:
20ltrs
Pressure Drop at Heat Ex:
15kPa
Pipe Connection:1" maleFan Info Quantity:Two
Airflow Rate:100m³/minOutput Power:14.9kW
Refrigerant Side Compressor Type:Rotary InverterOil:POE
Compressor Power:
4.6kW
Refrigerant Type:R410ARefrigerant Factory
Charge:2.2kg
Electrical Info Max Running Current:
30A
Starting Current:2ARecommended Fuse Size:
32A
Sound Info Sound Pressure Level
53dB(A)
Sound Power Level70dB(A)Net Dimensions HWD (mm) 1,420 x 940 x 330Net Weight: 103kgOperating Range Ambient (A2W): -20°C to 35°C
Leaving Water: 25°C to 55°C
Samsung Components
46
Hitachi Prestige PacksHitachi
Description Part Code List PriceHITACHIYUTAKI-M7.5kW/3HPPRESTIGEHEATPUMPPACK
£4,593.44
Hitachi Yutaki-M RHUE3.0AVHN1 MonoBloc ATW Heat Pump
SolfexHIT-PHPK-001
Hitachi Yutaki-M Control Kit CPS 931702Anti Vibration Feet PTS SOLHITPHPK1Flexible Hose Set TP 931702Isolation Valves2 Port Zone ValvesFlow Meter with Filling / Flushing ValveIn-Line Magnetic Filter4-Pole Isolator SwitchBuffer Tank
HIT-RHUE3.0AVHN1–CASEBASEANDCOILCORROSIONPROTECTION
£427.35
Corrosion protection when utilized in aggressive environments
Solfex HIT-CBCP-7.5
Coastal or high pollution applications CPS 7618805 Year Anti-Corrosion Warranty PTS SOLHICBCP7.5
TP 761880
HIT-RHUE3.0AVHN1–HEATPUMPCASECOLOURSELECTOR
£309.83
Can be utilized with or without corrosion protection. Solfex HIT-CS-7.5Colours available conform to RAL colour matching system.
CPS761882
Please contact Solfex Heat Pump Sales for further information.
PTS SOLHICS7.5
TP 761882
HITACHIYUTAKI-M14kW/6HPPRESTIGEHEATPUMPPACK
£5,752.49
Hitachi Yutaki-M RHUE6.0AVHN1 MonoBloc ATW Heat Pump
SolfexHIT-PHPK-002
Hitachi Yutaki-M Control Kit CPS 931703Anti Vibration Feet PTS SOLHITPHPK2Flexible Hose Set TP 931703Isolation Valves2 Port Zone ValvesFlow Meter with Filling / Flushing ValveIn-Line Magnetic Filter4-Pole Isolator SwitchBuffer Tank
HIT-RHUE6.0AVHN–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Corrosion protection when utilized in aggressive environments
SolfexHIT-CBCP-14
Coastal or high pollution applications CPS 7618815 Year Anti-Corrosion Warranty PTS SOLHICBCP14
TP 761881
HIT-RHUE6.0AVHN–HEATPUMPCASECOLOURSELECTOR
£395.30
Can be utilized with or without corrosion protection. Solfex HIT-CS-14Colours available conform to RAL colour matching system.
CPS955952
Please contact Solfex Heat Pump Sales for further information.
PTS SOLHICS14KW
TP 955952
47
Hitachi Prestige PacksHitachi
Description Part Code List PriceHITACHIYUTAKI-S806HPPRESTIGEHEATPUMPPACK
£8,362.86
HITACHI YUTAKI-S80 6HP OUTDOOR UNIT Solfex HIT-PHPK-S80-001HITACHI YUTAKI-S80 6HP INDOOR UNIT CPS 931704HITACHI YUTAKI-S80 HEAT PUMP SYSTEM CONTROL PACK
PTSSOLHIPHPKS80
Anti Vibration Feet TP 931704Isolation ValvesFlow Meter with Filling / Flushing ValveIn-Line Magnetic Filter4-Pole Isolator SwitchBuffer Tank
HIT-RAS-6HVRNME-AF–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Corrosion protection when utilized in aggressive environments
SolfexHIT-CBCP-S80
Coastal or high pollution applications CPS 9559515 Year Anti-Corrosion Warranty PTS SOLHICBCPS80
TP 955951
HIT-RAS-6HVRNME-AF–HEATPUMPCASECOLOURSELECTOR
£395.30
Can be utilized with or without corrosion protection. Solfex HIT-CS-S80Colours available conform to RAL colour matching system.
CPS761883
Please contact Solfex Heat Pump Sales for further information.
PTS SOLHICS-S80
TP 761883
HIT-RWH-6.0FSNFE–HEATPUMPCASECOLOURSELECTOR
£287.26
Can be utilized with or without corrosion protection. Solfex HIT-CS-S80INColours available conform to RAL colour matching system.
CPS955953
Please contact Solfex Heat Pump Sales for further information.
PTS SOLHICSS80IN
TP 955953
48
Hitachi ComponentsHitachi
Description Part Code List PriceHitachiYutaki-M7.5kW/3HPMonoBlocATWHeatPump
£3,161.46
Power Supply Ø = 1 Solfex HIT-RHUE3.0AVHN1
V = 230 CPS 737632Hz = 50 PTS SOLHITRHUE3
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: 7.5kW TP 737632Electrical Input: 1.69kWCOP: 4.43
Performance Air 7ºC Flow 40/45ºC
Heating Output: 7.1kWElectrical Input: 2.13kWCOP: 3.34
Performance Air -7ºC Flow 30/35ºC
Heating Output: 6.kWElectrical Input: 2.71kWCOP: 2.4
Performance Air -7ºC Flow 40/45ºC
Heating Output: 6.2kWElectrical Input: 3.18kWCOP: 2.01
Water Side Heat Exchanger Type:
Brazed Plate
Max Permissible Water Press.
1.0 bar
Nominal Water Flow Rate:
22lpm
Minimum Water Volume:
100ltrs
Pressure Drop at Heat Ex:
6.8kPa at Nominal Condition
Pipe Connection: 1” MaleFan Info Quantity: One
Airflow Rate: 68m³/minOutput Power: 138W
Refrigerant Side Compressor Type: Hermetic ScrollOil: FVC68DCompressor Power:
1.38kW
Refrigerant Type: R410ARefrigerant Factory Charge:
2.6kg
Electrical Info Running Current: 7.5A (excludes pump)
Starting Current: 2ARecommended Fuse Size:
32A
Sound Info Sound Pressure Level
49dB (A) at 1m from front of unit
Sound Power Level68dB (A)Dimensions: 800 x 1250 x
440mm (H x W x D)
Weight: 110kg NetOperating Range Ambient (A2W): Heating:
-20~37.5ºC (WB)Leaving Water: Heating: 20~60ºC
49
Hitachi ComponentsHitachi
Description Part Code List PriceHitachiYutaki-M14kW/6HPMonoBlocATWHeatPump
£4,242.45
Power Supply Ø = 1 Solfex HIT-RHUE6.0AVHN
V = 230 CPS 931701Hz = 50 PTS SOLHITRHUE6
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output:14kW TP 931701Electrical Input:3.25kW
COP:4.31
Performance Air 7ºC Flow 40/45ºC
Heating Output:13.3kWElectrical Input:3.97kW
COP:3.35Performance Air -7ºC Flow 30/35ºC
Heating Output:9.3kWElectrical Input:3.58kW
COP:2.60Performance Air -7ºC Flow 40/45ºC
Heating Output:9kWElectrical Input:4.07kW
COP:2.21Water Side Heat Exchanger
Type:Brazed Plate
Max Permissible Water Press.
1.0 bar
Nominal Water Flow Rate:
40lpm
Minimum Water Volume:
156ltrs
Pressure Drop at Heat Ex:
12.0kPa at Nominal Condition
Pipe Connection:1” MaleFan Info Quantity:Two
Airflow Rate:100m³/minOutput Power:70W + 70W
Refrigerant Side Compressor Type:DC Inverter DrivenOil:FVC68D
Compressor Power:
2.5kW
Refrigerant Type:R410ARefrigerant Factory
Charge:4.2kg
Electrical Info Running Current:17.6A (excludes pump)
Starting Current:2ARecommended
Fuse Size:32A
Sound Info Sound Pressure Level
52dB (A) at 1m from front of unit
Sound Power Level68dB (A)Dimensions: 1480 x 1250 x
444mm (H x Wx D)
Weight: 159kg NetOperating Range Ambient (A2W):Heating: -20 -
+35ºCLeaving Water:Heating: 20~55ºC
HITACHIYUTAKI-MHEATPUMPSYSTEMCONTROLPACK
£531.64
Power Supply V = 230Vac +10%, -15%, 50Hz Solfex HIT-ATW-CPA-02Hz = 50 CPS 737629
Degree of Protection
IP30(with terminal covers) PTS SOLHIAWCPA02
Dimensions 215.5 W x 147 H x 57.5 D mm (with terminal covers) TP 737629
50
HitachiDescription Part Code List PriceHITACHIYUTAKI-S806HPOUTDOORUNIT £1,951.10Power Supply Ø = 1 Solfex HIT-RAS-
6HVRNME-AFV = 230 CPS 737631Hz = 50 PTS SOLHITRAS6
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: 14.0kW TP 737631Electrical Input: 3.46kWCOP: 4.05
When connected to HIT-RWH-6.0FSNFEPerformance Air 7ºC Flow 40/45ºC
Heating Output: 14.0kWElectrical Input: 4.22kWCOP: 3.32
When connected to HIT-RWH-6.0FSNFEPerformance Air -7ºC Flow 30/35ºC
Heating Output: 9.4kWElectrical Input: 4.14kWCOP: 2.29
When connected to HIT-RWH-6.0FSNFEPerformance Air -7ºC Flow 40/45ºC
Heating Output: 14.0kWElectrical Input: 6.22kWCOP: 2.25
When connected to HIT-RWH-6.0FSNFEFan Info Quantity: Two
Airflow Rate: 100m³/minOutput Power: 70W + 70W
Refrigerant Gas Pipe Required: 5/8”Liquid Pipe Required:
3/8”
Compressor Power:
2.5kW
Refrigerant Type: R410ARefrigerant Factory Charge:
4.00kg
Heat Exchanger Type:
Multi-Pass Cross-Finned Tube
Electrical Info Running Current: 14.5A (excludes pump)
Starting Current: <10ARecommended Fuse Size:
25A
Sound Info Sound Pressure Level
48dB (A) at 1m from front of unit
Sound Power Level67dB (A)Dimensions: 1380 x 950 x
370mm (H x W x D)
Weight: 104kg NetOperating Range Ambient (A2W): Heating:
-20~35ºC (WB)
Hitachi Components
51
HitachiDescription Part Code List PriceHITACHIYUTAKI-S806HPINDOORUNIT £5,264.96Power Supply Ø = 1 Solfex HIT-RWH-
6.0FSNFEV = 230 CPS 737633Hz = 50 PTS SOLHITRWH6
Refrigerant Gas Pipe Required: 5/8” TP 737633Liquid Pipe Required:
3/8”
Pipe Length: 30mCompressor Power:
3.0kW
Refrigerant Type: R-134aRefrigerant Factory Charge:
2.5kg
Electrical Info Running Current: 14.7AMax Current: 31.0ARecommended Fuse Size:
32A
Sound Info Sound Pressure Level
41dB (A) @ A7 & W55/65°C
Sound Power Level57dB (A)Dimensions: 595 x 706 x
695mm (W x H x D)
Weight: 162kg NetOperating Range Water Outlet
Temperature:30~80°C
Internal Temperature:
5~35ºC
Water Side Heat Exchanger Type:
Stainless Steel
Expansion Vessel Volume:
12ltr
Nominal Water Flow Rate:
40lpm
Minimum Water Volume:
200ltrs
Heating Pipe Connection:
1” Male
DHW Pipe Connection:
3/4” Male
Pump Input Power: 75W
HITACHIYUTAKI-S80HEATPUMPSYSTEMCONTROLPACK
£177.22
Dimensions: Height: 118mm Solfex HIT-PC-S80TEWidth: 118mm CPS 931699Depth: 22mm PTS SOLHIPCS80TEWeight: 0.5kg TP 931699
HITACHIYUTAKIS/S80WIRELESSROOMCONTROLUNIT
£159.50
Dimensions: Room Stat HWD 88 x 131 x 22 Solfex HIT-ATW-RTU-02Receiver HWD 88 x 83 x 27 CPS 956335Weight: 0.6kg PTS SOLHIAWRTU02
TP 956335
Hitachi Components
52
LG Prestige PacksDescription Part Code List PriceLGLGTHERMA-V3kWPRESTIGEAIRSOURCEHEATPUMPPACK
£2,717.98
Solfex LG-PHPK-001LG Therma-V HM031M.U42 Monobloc c/w controls CPS 761914Anti Vibration Feet PTS SOLLGPHPK001Insulated Flexible Hose Set TP 761914Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
HM031M.U42–CASEBASEANDCOILCORROSIONPROTECTION
£427.35
Corrosion protection when utilized in aggressive environments
Solfex LG-CBCP-3KW
Coastal or high pollution applications CPS 9559685 Year Anti-Corrosion Warranty PTS SOLLGCBCP3KW
TP 955968
HM031M.U42–HEATPUMPCASECOLOURSELECTOR
£309.83
Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-3KWPlease contact Solfex Heat Pump Sales for further information. CPS 955972
PTS SOLLGCS3KWTP 955972
LGTHERMA-V5kWPRESTIGEAIRSOURCEHEATPUMPPACK
£3,485.70
Solfex LG-PHPK-002LG Therma-V HM051M.U42 Monobloc c/w controls CPS 955984Anti Vibration Feet PTS SOLLGPHPK002Insulated Flexible Hose Set TP 955984Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
HM051M.U42–CASEBASEANDCOILCORROSIONPROTECTION
£427.35
Corrosion protection when utilized in aggressive environments
Solfex LG-CBCP-5KW
Coastal or high pollution applications CPS 7618995 Year Anti-Corrosion Warranty PTS SOLLGCBCP5KW
TP 761899
HM051M.U42–HEATPUMPCASECOLOURSELECTOR
£309.83
Can be utilized with or without corrosion protection. Solfex LG-CS-5KWColours available conform to RAL colour matching system. CPS 761903Please contact Solfex Heat Pump Sales for further information. PTS SOLLGCS5KW
TP 761903
53
Description Part Code List PriceLGLGTHERMA-V7kWPRESTIGEAIRSOURCEHEATPUMPPACK
£3,642.70
Solfex LG-PHPK-003LG Therma-V HM071M.U42 Monobloc c/w controls CPS 955985Anti Vibration Feet PTS SOLLGPHPK003Insulated Flexible Hose Set TP 955985Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
HM071M.U42–CASEBASEANDCOILCORROSIONPROTECTION
£427.35
Corrosion protection when utilized in aggressive environments
Solfex LG-CBCP-7KW
Coastal or high pollution applications CPS 955969
5 Year Anti-Corrosion WarrantyPTS
SOLLGCBCP7KW
TP 955969HM071M.U42–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-7KWPlease contact Solfex Heat Pump Sales for further information. CPS 955973
PTS SOLLGCS7KWTP 955973
LGTHERMA-V9kWPRESTIGEAIRSOURCEHEATPUMPPACK
£3,912.70
Solfex LG-PHPK-004LG Therma-V HM091M.U42 Monobloc c/w controls CPS 761916Anti Vibration Feet PTS SOLLGPHPK004Insulated Flexible Hose Set TP 761916Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
HM091M.U42–CASEBASEANDCOILCORROSIONPROTECTION
£427.35
Corrosion protection when utilized in aggressive environments
Solfex LG-CBCP-9KW
Coastal or high pollution applications CPS 761900
5 Year Anti-Corrosion WarrantyPTS
SOLLGCBCP9KW
TP 761900
HM091M.U42–HEATPUMPCASECOLOURSELECTOR £309.83Can be utilized with or without corrosion protection. Solfex LG-CS-9KWColours available conform to RAL colour matching system. CPS 955974Please contact Solfex Heat Pump Sales for further information. PTS SOLLGCS9KW
TP 955974
LG Prestige Packs
54
Description Part Code List PriceLGLGTHERMA-V12kWPRESTIGEAIRSOURCEHEATPUMPPACK
£5,056.18
Solfex LG-PHPK-005LG Therma-V HM121M.U32 Monobloc c/w controls CPS 761917Anti Vibration Feet
PTS SOLLGPHPK005
Insulated Flexible Hose Set TP 761917Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
HM121M.U32–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Corrosion protection when utilized in aggressive environments
Solfex LG-CBCP-12KW
Coastal or high pollution applications CPS 9559705 Year Anti-Corrosion Warranty PTS SOLLGCBCP12
TP 955970HM121M.U32–HEATPUMPCASECOLOURSELECTOR
£395.30
Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-12KWPlease contact Solfex Heat Pump Sales for further information. CPS 761905
PTS SOLLGCS12KWTP 761905
LGTHERMA-V14kWPRESTIGEAIRSOURCEHEATPUMPPACK
£5,435.18
Solfex LG-PHPK-006LG Therma-V HM141M.U32 Monobloc c/w controls CPS 761918Anti Vibration Feet PTS SOLLGPHPK006Insulated Flexible Hose Set TP 761918Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
HM141M.U32–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Corrosion protection when utilized in aggressive environments Solfex LG-CBCP-14KWCoastal or high pollution applications CPS 9559715 Year Anti-Corrosion Warranty PTS SOLLGCBCP14
TP 955971
HM141M.U32–HEATPUMPCASECOLOURSELECTOR
£395.30
Can be utilized with or without corrosion protection. Solfex LG-CS-14KWColours available conform to RAL colour matching system. CPS 955976Please contact Solfex Heat Pump Sales for further information. PTS SOLLGCS14KW
TP 955976
LG Prestige Packs
55
Description Part Code List PriceLG
LGTHERMA-V16kWPRESTIGEAIRSOURCEHEATPUMPPACK
£5,823.18
Solfex LG-PHPK-007LG Therma-V HM161M.U32 Monobloc c/w controls CPS 955988Anti Vibration Feet PTS SOLLGPHPK007Insulated Flexible Hose Set TP 955988Isolation Valves2 Port ValvesGlycolFlow Meter with Filling / Flushing ValveIn-Line Magnetic FilterVarious Brassware4-Pole Isolator Switch
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
HM161M.U32–CASEBASEANDCOILCORROSIONPROTECTION
£555.56
Corrosion protection when utilized in aggressive environments
Solfex LG-CBCP-16KW
Coastal or high pollution applications CPS 7619025 Year Anti-Corrosion Warranty PTS SOLLGCBCP16
TP 761902HM161M.U32–HEATPUMPCASECOLOURSELECTOR
£395.30
Can be utilized with or without corrosion protection.Colours available conform to RAL colour matching system. Solfex LG-CS-16KWPlease contact Solfex Heat Pump Sales for further information. CPS 761907
PTS SOLLGCS16KWTP 761907
LG Prestige Packs
56
Description Part Code List PriceLGLGTHERMA-V3KWMONOBLOCKAIRSOURCEHEATPUMP
£2,213.00
Solfex LG-HM031M.U42
Power Supply
Phase = 1V = 220-240 CPS 761919
Hz = 50Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 3 PTS SOLLGHM031MElectrical Input: kW 0.73
COP: 4.1TP 761919
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 2.75Electrical Input: kW 0.85
COP: 3.24Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 2.45Electrical Input: kW 0.95
COP: 2.58Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 2.17Electrical Input: kW 1.04
COP: 2.09
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 5.6Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 8.25Pipe Connection: inch 1”
Fan Info Quantity: - 1
Airflow Rate:m3/min 32
Output Power: W 124
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 1.5Refrigerant Type: - R410A
Refrigerant Factory Charge: g 750
Electrical Info Running Current:MAX,
A 10Starting Current: A 2Recommended
Fuse Size: A 20
Sound InfoSound Pressure
Level dBA 47Sound Power
Level dBA 55Dimensions: HWD 834x950x330Weight: kg 61Operating Range Ambient (A2W): C -20 ~ 30
Leaving Water: C 20 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
57
Description Part Code List PriceLG
LGTHERMA-V5KWMONOBLOCKAIRSOURCEHEATPUMP
£2,950.00
Solfex LG-HM051M.U42Power Supply Phase = 1
V = 220-240 CPS 955989Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 4.99 PTS SOLLGHM051MElectrical Input: kW 1.13
COP: 4.4TP 955989
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 4.58Electrical Input: kW 1.33
COP: 3.44Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 4.07Electrical Input: kW 1.48
COP: 2.75Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 3.62Electrical Input: kW 1.62
COP: 2.23
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 14.3Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 10.18Pipe Connection: inch 1”
Fan Info Quantity: - 1
Airflow Rate:m3/min 50
Output Power: W 124
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 2.1Refrigerant Type: - R410A
Refrigerant Factory Charge: g 1200
Electrical Info Running Current:MAX,
A 13Starting Current: A 2Recommended
Fuse Size: A 20
Sound InfoSound Pressure
Level dBA 51Sound Power
Level dBA 63Dimensions: HWD 907x1239x390Weight: kg 97Operating Range Ambient (A2W): C -20 ~ 35
Leaving Water: C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
58
Description Part Code List PriceLGLGTHERMA-V7KWMONOBLOCKAIRSOURCEHEATPUMP
£3,107.00
Solfex LG-HM071M.U42Power Supply Phase = 1
V = 220-240 CPS 761921Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 7 PTS SOLLGHM071MElectrical Input: kW 1.63
COP: 4.3TP 761921
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 6.41Electrical Input: kW 1.9
COP: 3.37Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 5.71Electrical Input: kW 2.12
COP: 2.69Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 3.62Electrical Input: kW 1.62
COP: 2.23
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 20.1Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 11.54Pipe Connection: inch 1”
Fan Info Quantity: - 1
Airflow Rate:m3/min 60
Output Power: W 124
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 2.1Refrigerant Type: - R410A
Refrigerant Factory Charge: g 1450
Electrical Info Running Current:MAX,
A 14Starting Current: A 2Recommended
Fuse Size: A 20
Sound InfoSound Pressure
Level dBA 52Sound Power
Level dBA 65Dimensions: HWD 907x1239x390Weight: kg 98Operating Range Ambient (A2W): C -20 ~ 35
Leaving Water: C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
59
Description Part Code List PriceLG
LGTHERMA-V9KWMONOBLOCKAIRSOURCEHEATPUMP
£3,377.00
Solfex LG-HM091M.U42Power Supply Phase = 1
V = 220-240 CPS 955991Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 9 PTS SOLLGHM091MElectrical Input: kW 2.2
COP: 4.1TP 955991
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 8.25Electrical Input: kW 2.44
COP: 3.38Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 7.34Electrical Input: kW 2.72
COP: 2.7Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 6.51Electrical Input: kW 2.96
COP: 2.2
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 25.8Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 11.71Pipe Connection: inch 1”
Fan Info Quantity: - 1
Airflow Rate:m3/min 60
Output Power: W 124
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 2.1Refrigerant Type: - R410A
Refrigerant Factory Charge: g 1600
Electrical Info Running Current:MAX,
A 15Starting Current: A 2Recommended
Fuse Size: A 20
Sound InfoSound Pressure
Level dBA 52Sound Power
Level dBA 65Dimensions: HWD 907x1239x390Weight: kg 99Operating Range Ambient (A2W): °C -20 ~ 35
Leaving Water: °C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
60
Description Part Code List PriceLGLGTHERMA-V12KWMONOBLOCKAIRSOURCEHEATPUMP
£4,475.00
Solfex LG-HM121M.U32Power Supply Phase = 1
V = 220-240 CPS 761922Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 12 PTS SOLLGHM121MElectrical Input: kW 2.67
COP: 4.49TP 761922
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 11Electrical Input: kW 3.18
COP: 3.46Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 9.8Electrical Input: kW 3.55
COP: 2.76Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 8.73Electrical Input: kW 4.02
COP: 2.17
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 34.4Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 14.5Pipe Connection: inch 1”
Fan Info Quantity: - 2
Airflow Rate:m3/min 60 x 2
Output Power: W 124 x2
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 4Refrigerant Type: - R410A
Refrigerant Factory Charge: g 2200
Electrical Info Running Current:MAX,
A 25Starting Current: A 2Recommended
Fuse Size: A 32
Sound InfoSound Pressure
Level dBA 53Sound Power
Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35
Leaving Water: °C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
61
Description Part Code List PriceLG
LGTHERMA-V14KWMONOBLOCKAIRSOURCEHEATPUMP
£4,854.00
Solfex LG-HM141M.U32Power Supply Phase = 1
V = 220-240 CPS 761923Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 14 PTS SOLLGHM141MElectrical Input: kW 3.15
COP: 4.44TP 761923
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 12.83Electrical Input: kW 3.8
COP: 3.38Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 9.8Electrical Input: kW 3.55
COP: 2.76Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 10.31Electrical Input: kW 4.7
COP: 2.19
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 40.1Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 16.2Pipe Connection: inch 1”
Fan Info Quantity: - 2
Airflow Rate:m3/min 60 x 2
Output Power: W 124 x2
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 4Refrigerant Type: - R410A
Refrigerant Factory Charge: g 2200
Electrical Info Running Current:MAX,
A 25Starting Current: A 2Recommended
Fuse Size: A 32
Sound InfoSound Pressure
Level dBA 53Sound Power
Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35
Leaving Water: °C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
62
Description Part Code List PriceLGLGTHERMA-V16KWMONOBLOCKAIRSOURCEHEATPUMP
£5,242.00
Solfex LG-HM161M.U32Power Supply Phase = 1
V = 220-240 CPS 955993Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 16 PTS SOLLGHM161MElectrical Input: kW 3.81
COP: 4.2TP 955993
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 14.6Electrical Input: kW 4.45
COP: 3.28Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 13.01Electrical Input: kW 4.93
COP: 2.64Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 11.48Electrical Input: kW 5.16
COP: 2.22
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 45.9Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 18.52Pipe Connection: inch 1”
Fan Info Quantity: - 2
Airflow Rate:m3/min 60 x 2
Output Power: W 124 x2
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 4Refrigerant Type: - R410A
Refrigerant Factory Charge: g 2200
Electrical Info Running Current:MAX,
A 25Starting Current: A Soft startRecommended
Fuse Size: A 32
Sound InfoSound Pressure
Level dBA 53Sound Power
Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35
Leaving Water: °C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
63
Description Part Code List PriceLG
LGTHERMA-V12KWMONOBLOCKAIRSOURCEHEATPUMP(3PHASE)
£4,699.00
Solfex LG-HM123M.U32Power Supply Phase = 3
V = 380-415 CPS 955996Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 12 PTS SOLLGHM123MElectrical Input: kW 2.67
COP: 4.49TP 955996
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 11.28Electrical Input: kW 3.31
COP: 3.41Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 9.82Electrical Input: kW 3.56
COP: 2.76Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 8.92Electrical Input: kW 4.11
COP: 2.17
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 34.4Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 14.5Pipe Connection: inch 1"
Fan Info Quantity: - 2
Airflow Rate:m3/min 60 x 2
Output Power: W 124 x2
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 4Refrigerant Type: - R410A
Refrigerant Factory Charge: g 2200
Electrical Info Running Current:MAX,
A 11Starting Current: A 2Recommended
Fuse Size: A 20
Sound InfoSound Pressure
Level dBA 53Sound Power
Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35
Leaving Water: °C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
64
Description Part Code List PriceLGLGTHERMA-V14KWMONOBLOCKAIRSOURCEHEATPUMP(3PHASE)
£5,097.00
Solfex LG-HM143M.U32Power Supply Phase = 3
V = 380-415 CPS 955997Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC
Heating Output: kW 14 PTS SOLLGHM143MElectrical Input: kW 3.15
COP: 4.44TP 955997
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 13.16Electrical Input: kW 3.92
COP: 3.36Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 11.41Electrical Input: kW 4.22
COP: 2.7Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 10.38Electrical Input: kW 4.77
COP: 2.18
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 40.1Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 16.2Pipe Connection: inch 1”
Fan Info Quantity: - 1
Airflow Rate:m3/min 60 x 2
Output Power: W 124 x2
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 4Refrigerant Type: - R410A
Refrigerant Factory Charge: g 2200
Electrical Info Running Current:MAX,
A 11Starting Current: A 2Recommended
Fuse Size: A 20
Sound InfoSound Pressure
Level dBA 53Sound Power
Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35
Leaving Water: °C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
65
LG-PHLTB SANITARY TANK KIT FOR MONOBLOC £169.00In order to use a domestic hot water with an LG Heat Pump, Solfex LG-PHLTBthis accessory must be purchased. CPS 762272Please contact Solfex Technical for further details PTS SOLLGPHLTB
TP 762272
Description Part Code List PriceLG
LGTHERMA-V16KWMONOBLOCKAIRSOURCEHEATPUMP(3PHASE)
£5,504.00
Solfex LG-HM163M.U32Power Supply Phase = 3
V = 380-415 CPS 955998Hz = 50
Nominal Condition Air 7ºC Flow 30/35ºC Heating Output: kW 16
PTS SOLLGHM163M
Electrical Input: kW 3.81COP: 4.2 TP 955998
Performance Air 7ºC Flow 40/45ºC
Heating Output: kW 15.41Electrical Input: kW 4.62
COP: 3.34Performance Air -7ºC Flow 30/35ºC
Heating Output: kW 13.26Electrical Input: kW 5.29
COP: 2.51Performance Air -7ºC Flow 40/45ºC
Heating Output: kW 12.13Electrical Input: kW 5.65
COP: 2.15
Water SideHeat Exchanger
Type: Brazed plate HEXMax Permissible
Water Press. bar 3Nominal Water
Flow Rate: l/min 45.9Minimum Water
Volume: l 20Pressure Drop at
Heat Ex: kPa 18.52Pipe Connection: inch 1”
Fan Info Quantity: - 1
Airflow Rate:m3/min 60 x 2
Output Power: W 124 x2
Refrigerant Side Compressor Type: -
Hermetic, Brushless DC motor
Oil: FVC68DCompressor
Power: kW 4Refrigerant Type: - R410A
Refrigerant Factory Charge: g 2200
Electrical Info Running Current:MAX,
A 11Starting Current: A 2Recommended
Fuse Size: A 20
Sound InfoSound Pressure
Level dBA 53Sound Power
Level dBA 67Dimensions: HWD 1450x1239x390Weight: kg 141Operating Range Ambient (A2W): °C -20 ~ 35
Leaving Water: °C 15 ~ 57
LG Components
Pleasenote:IfyouwouldliketouseadomestichotwatercylinderwiththeLGrangeofHeatPumps,accessoryLG-PHLTBisrequired
66
Heat Pump AccessoriesHeat Pump Accessories
Description Part Code List PriceFLEXIFOOTFIXINGKIT £11.90
Solfex HP-FF-FIXPACKFor the fixation of the ASHP to the Flexi Foot 600 CPS 908486Delivery: 4x nut, 4x bolt, 4x spring washer PTS SOLHPFFFIXPK
TP 908486
FLEXIFOOT600 £20.44Dimensions (L x W x H): 600mm x 185mm x 100mm Solfex HP-FF-600-SWeight: 7.6kg CPS 132210Max Load: 300kg PTS SOLHPFF600SDelivery: 1pc TP 132210
FLEXIFOOT600COMPLETEWITHFIXINGKIT £52.78Dimensions (L x W x H): 600mm x 185mm x 100mm Solfex HP-FF-600-S-KITWeight: 7.6kg CPS 762257Max Load: 300kg PTS SOLHPFF600KTDelivery: 1pc TP 762257FLEXI FOOT FIXING KITFor the fixation of the ASHP to the Flexi Foot 600Delivery: 4x nut, 4x bolt, 4x spring washer
AIRSOURCEHEATPUMPWALLMOUNTINGBRACKETWITHCROSSBAR
£96.84
Solfex HP-WMB-001Suitable for Samsung EHS Monobloc 9kW & 16kW units CPS 908474Delivery: 1pc PTS HPWMB001
TP 908474
ANTI-VIBRATIONMOUNTINGBOLTS £25.50M8 nuts and washers to suit wall mounting brackets Solfex HP-AVMB-001Delivery: 4pc CPS 761870
PTS SOLHPAVMB001TP 761870
22MMCOMPRESSIONFLUSH/FILLVALVE £23.10Solfex HP-FF588
Delivery: 1pc CPS 714398PTS HPFF588TP 714398
1”BSPFEMALE3PORTDIVERTERVALVE £49.98Solfex HP-DIV-1
Action: Spring return CPS 356217Delivery: 1pc PTS HPDIV1
TP 356217
67
Heat Pump AccessoriesHeat Pump Accessories
Description Part Code List PriceINSULATEDFLEXIBLEASHPHOSEPAIR-750mmX28mm-1”FEMALE
£95.49
750mm Length Solfex HP-FLEXI-INS-119mm TC Insulation CPS 9559391” Female BSP Thread Fitting PTS SOLHPFLEXIN128mm Compression Fitting TP 955939
1”BSPFEMALEx1”BSPFEMALE1MFLEXIBLEBRAIDEDHOSE
£19.89
Solfex HP-FLEXI-1Delivery: 1pc CPS 714388
PTS HPFLEXI1TP 714388
1”HIGHTEMPERATUREGASKET £0.59Solfex HTGSKT-1
Delivery: 1pc CPS 956328PTS HTGSKT1TP 956328
28MMINLINEMAGNETICFILTERCOMPLETEWITHISOLATIONVALVES
£78.85
Solfex HP-FILT-28MMDelivery: 1pc CPS 372993
PTS SOLHPFILT28TP 372993
22MMCOMPRESSIONFULLBORELEVERARMVALVE(REDHANDLE)
£11.40
Solfex HP-VAL22RDelivery: 1pc CPS 522549
PTS HPVAL22RTP 522549
22MMCOMPRESSIONFULLBORELEVERARMVALVE(BLUEHANDLE)
£11.40
Solfex HP-VAL22BDelivery: 1pc CPS 908466
PTS HPVAL22BTP 908466
28MMCOMPRESSIONFULLBORELEVERARMVALVE(REDHANDLE)
£12.79
Solfex HP-VAL28RDelivery: 1pc CPS 714400
PTS HPVAL28RTP 714400
28MMCOMPRESSIONFULLBORELEVERARMVALVE(BLUEHANDLE)
£12.79
Solfex HP-VAL28BDelivery: 1pc CPS 714401
PTS HPVAL28BTP 714401
1”BSPFEMALEFLUSH/FILLVALVE&FLOWREGULATOR
£39.47
Solfex HP-FM1497Flow Rate: 8 - 38 lpm CPS 363241Delivery: 1pc PTS HPFM1497
TP 363241
68
Heat Pump AccessoriesDescription Part Code List Price22MMCOMPRESSION2PORTVALVE £52.70
Solfex VAL-60524600Action: Spring return CPS 613505Delivery: 1pc PTS SOLVA6052460
TP 613505
28MMCOMPRESSION2PORTVALVE £44.54Solfex VAL-60424600
Action: Spring return CPS 762259Delivery: 1pc PTS SOLVA6042460
TP 762259
1”BSPMALEx22MMCOMPRESSIONADAPTER £4.59Solfex FIT-1100G002206FD
Brass fitting CPS 908459Delivery: each PTS 100G002206FD
TP 908459
1”BSPMALEx28MMCOMPRESSIONADAPTER £5.78Solfex FIT-2057
Brass fitting CPS 714391Delivery: each PTS FIT2057
TP 714391
1”BSPMALEx1”BSPMALESTRAIGHTNIPPLE £3.64Solfex FIT-1552G000606FD
Brass fitting CPS 908457Delivery: each PTS 1552G00606FD
TP 908457
TYFOCORLPROPYLENEGLYCOL £45.48Solfex TYFOL10LTR
Concentrate - ready to use - 10L PE Can CPS 714430Delivery: each PTS TYFOL10LTR
TP 714430
ACIsolatingSwitchNEW324P £24.75Solfex AC-NEW324P
4 Pole Switch disconnector IP66/77 CPS 956331Rated Operating Current - 32Amps PTS SOLACNEW324P
TP 956331
HTARMAFLEX £12.54Insulation material: Foamed EPDM rubber Solfex HT-19X28Pipe size: 28mm CPS 908489Insulation thickness: 19mm PTS HT19X28Min/Max surface temperature: -200°C - +150°C Class 1 resistance to flame speed in
TP 908489
accordance with BS 476 Part 7 - UV resistantDelivery: 2 Mtr length
HTARMAFLEX £15.30Insulation material: Foamed EPDM rubber Solfex HT-25X28Pipe size: 28mm CPS 132214Insulation thickness: 25mm PTS HT25X28Min/Max surface temperature: -200°C - +150°C Class 1 resistance to flame speed in
TP132214
accordance with BS 476 Part 7 - UV resistantDelivery: 2 Mtr length
Heat Pump Accessories
69
Heat Pump AccessoriesDescription Part Code List Price
OWLINTUITION-HPW £276.30
With the new OWL Intuition Smart Heating Control home owners can….
Solfex OWL-TSE220-150
CPS 737636• Take control of their heating and hot water using any Internet connected device – desktop, laptop, tablet or even Smartphone and from they happen to be – at work, on holiday, even on the train
PTS SOLOWLSE2201
• Save up to 20% on their heating bills TP 737636• Use the OWL Intuition web dashboard to control their heating and hot water settings online
Comes complete with:Network Owl GatewayIntuition-Lc (Lge Sensors Pack)Intuition Relay Unit [RMT-6C]Intuition Room Sensor [RBT-3C]
SOLARCHECKMOBILCENTERKOMPAKTSOLARFILLING/FLUSHINGUNIT230VZUWA-P80
£533.27
Technical Specification Solfex FIL-134053V11UKPump Type: Self Priming Centrifugal Pump (dry run max 1 min) CPS 762260Max Flow Rate: 31 lpm PTS SOLFIL134053Max Pressure: 5.9 bar TP 762260Max Fluid Temp: 60 degrees CPower Supply 230V - 1.7m cable with plugTank Capacity: 30 litreHoses: 2 x 3mTelescopic Handle
HANDHELDREFRACTOMETER £117.70Solfex REF-402
For determination of glycol concentration CPS 163887Delivery: With carry case and manual PTS REF402
TP 163887
THROUGHWALLKIT £36.85Kit Contents Solfex HP-TWK-0012 x straight 320mm lengths. CPS 7622612 x custom slit elbows. PTS SOLHPTWK00119mm wall insulation with tough PVC coating. TP 762261Suitable for both 22mm and 28mm pipe
HEATMISERNeoStat-BLACKEDITION £86.25
Stunning design incorporating soft touch keysSolfex
UFH-CON-NEOSTAT-BK
Non Programmable, 5/2 Day, 7 Day and 24 Hour Programming
CPS 747095
5 Minute Program Intervals PTS SOLNEOSTATBKSelf Learning Optimum Start TP 747095
HEATMISERNeoStat-WHITEEDITION £86.25Stunning design incorporating soft touch keys Solfex UFH-CON-NEOSTATNon Programmable, 5/2 Day, 7 Day and 24 Hour Programming
CPS 747093
5 Minute Program Intervals PTS SOLNEOSTATWHSelf Learning Optimum Start TP 747093
Heat Pump Accessories
70
Pre Plumbed CylindersPre Plumbed Heat Pump Cylinders
Description Part Code List Price180LSOLFEXSLIMLINEPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER
£1,743.63
Capacity: 180ltr Solfex HP-PP-180-SLIMHeight: 1790mm CPS 762262Approx Diameter: 575mm PTS SOLHPPP180SLWeight (empty): 46.3kg TP 762262Weight (full): 226.3kgStanding Losses: 2.01kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:
2yrs
210LSOLFEXSLIMLINEPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER
£1,794.95
Capacity: 210ltr Solfex HP-PP-210-SLIMHeight: 1970mm CPS 956332Approx Diameter: 575mm PTS SOLHPPP210SLWeight (empty): 50.3kg TP 956332Weight (full): 260.3kgStanding Losses: 2.23kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:
2yrs
250LSOLFEXPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER
£1,865.30
Capacity: 250ltr Solfex HP-PP-250Height: 1745mm CPS 762263Approx Diameter: 650mm PTS SOLHPPP250Weight (empty): 56.3kg TP 762263Weight (full): 306.3kgStanding Losses: 1.85kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:
2yrs
300LSOLFEXPRE-PLUMBEDHEATPUMPUNVENTEDCYLINDER
£1,964.88
Capacity: 300ltr Solfex HP-PP-300Height: 1992mm CPS 956333Approx Diameter: 650mm PTS SOLHPPP300Weight (empty): 71.3kg TP 956333Weight (full): 371.3kgStanding Losses: 2.04kWhr/24hrSurface Area of Coil: 3m²Vessel Warranty: 25yrsCylinder Components & Electronics Warranty:
2yrs
71
Unvented CylindersUnvented Heat Pump Cylinders
Description Part Code List Price
SOLFEXENERGYSYSTEMS180LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER
£928.25
Size HxW: 1295 x 550mm Solfex SOLHP180Weight empty / full: 33 / 213 KG CPS 908462G3 Unvented Kit included PTS SOLHP180Standing losses: 1.40KWh/24h TP 908462Heat Pump Coil surface area: 1.36 M²Dedicated Solar Volume: 65L
SOLFEXENERGYSYSTEMS210LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER
£981.13
Size HxW: 1483 x 550mm Solfex SOLHP210Weight empty / full: 38 / 248KG CPS 908465G3 Unvented Kit included PTS SOLHP210Standing losses: 1.60KWh/24hr TP 908465Heat Pump Coil surface area: 1.56 M²Dedicated Solar Volume: 75L
SOLFEXENERGYSYSTEMS250LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER
£1,075.13
Size HxW: 1733 x 550mm Solfex SOLHP250Weight empty / full: 43 / 293 KG CPS 132192G3 Unvented Kit included PTS SOLHP250Standing losses: 1.75KWh/24hr TP 132192Heat Pump Coil surface area: 1.94 M²Dedicated Solar Volume: 90L
SOLFEXENERGYSYSTEMS300LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER
£1,175.00
Size HxW: 2020 x 550mm Solfex SOLHP300Weight empty / full: 49 / 349 KG CPS 714403G3 Unvented Kit included PTS SOLHP300Standing losses: 1.93KWh/24hr TP 714403Heat Pump Coil surface area: 2.04 M²Dedicated Solar Volume: 105L
SOLFEXENERGYSYSTEMS400LCASEDINDIRECTUNVENTEDHEATPUMP&SOLARCYLINDER
£1,468.75
Size HxW: 2040 x 630mm Solfex SOLHP400Weight empty / full: 61 / 461 KG CPS 714404G3 Unvented Kit included PTS SOLHP400Standing losses: 3.33KWh/24hr TP 714404Heat Pump Coil surface area: 2.91 M²Dedicated Solar Volume: 130L
SOLFEXENERGYSYSTEMS180LCASEDINDIRECTUNVENTEDSLIMLINEHEATPUMPCYLINDER
£928.25
Size HxW: 1790 x 475mm Solfex SOLHP180SLIMWeight empty / full: 33 / 213 KG CPS 714394G3 Unvented Kit included PTS SOLHP180SLIMStanding losses: 2.01KWh/24hr TP 714394Heat Pump Coil surface area: 3.01 M²
SOLFEXENERGYSYSTEMS210LCASEDINDIRECTUNVENTEDSLIMLINEHEATPUMPCYLINDER
£981.13
Size HxW: 2005 x 475mm Solfex SOLHP210SLIMWeight empty / full: 37 / 247 KG CPS 762913G3 Unvented Kit included PTS SOLHP210SLIMStanding losses: 2.23KWh/24hr TP 762913Heat Pump Coil surface area: 3.01 M²
72
Open Vented CylindersOpen Vented Heat Pump Cylinders
Description Part Code List Price180LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER
£806.44
Size HxW : 1295 x 550mm Solfex SOLHP180OVWeight empty / full : 33 / 213 KG CPS 762266Standing losses : 1.40KWh/24hr PTS SOLHP180OVHeat Pump Coil surface area : 1.36 M² TP 762266Dedicated Solar Volume : 65L
SOLFEXENERGYSYSTEMS210LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER
£854.23
Size HxW : 1483 x 550mm Solfex SOLHP210OVWeight empty / full : 38 / 248KG CPS 956336Standing losses : 1.60KWh/24hr PTS SOLHP210OVHeat Pump Coil surface area : 1.56 M² TP 956336Dedicated Solar Volume : 75L
SOLFEXENERGYSYSTEMS250LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER
£952.80
Size HxW : 1733 x 550mm Solfex SOLHP250OVWeight empty / full : 43 / 293 KG CPS 762267Standing losses : 1.75KWh/24hr PTS SOLHP25OVHeat Pump Coil surface area : 1.94 M² TP 762267Dedicated Solar Volume : 90L
SOLFEXENERGYSYSTEMS300LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER
£1,049.75
Size HxW : 2020 x 550mm Solfex SOLHP300OVWeight empty / full : 49 / 349 KG CPS 762268Standing losses : 1.93KWh/24hr PTS SOLHP30OVHeat Pump Coil surface area : 2.04 M² TP 762268Dedicated Solar Volume : 105L
SOLFEXENERGYSYSTEMS400LCASEDINDIRECTOPENVENTEDHEATPUMP&SOLARCYLINDER
£1,344.15
Size HxW : 2040 x 630mm Solfex SOLHP400OVWeight empty / full : 61 / 461 KG CPS 956338Standing losses : 3.33KWh/24hr PTS SOLHP40OVHeat Pump Coil surface area : 2.91 M² TP 956338Dedicated Solar Volume : 130L
SOLFEXENERGYSYSTEMS180LCASEDINDIRECTSLIMLINEOPENVENTEDHEATPUMPCYLINDER
£806.44
Size HxW : 1790 x 475mm Solfex SOLHP180SLIMOV
Weight empty / full : 33 / 213KG CPS 956340
Standing losses : 2.01KWh/24hr PTS SOLHP18SLIOV
Heat Pump Coil surface area : 3.01 M² TP 956340
SOLFEXENERGYSYSTEMS210LCASEDINDIRECTSLIMLINEOPENVENTEDHEATPUMPCYLINDER
£854.23
Size HxW : 2005 x 475mm Solfex SOLHP210SLIMOV
Weight empty / full : 37 / 247 KG CPS 956341
Standing losses : 2.23KWh/24hr PTS SOLHP21SLIOV
Heat Pump Coil surface area : 3.01 M² TP 956341
73
Direct Stainless Steel BuffersDirect Stainless Steel Buffers
Description Part Code List PriceSOLFEXENERGYSYSTEMS90LCASEDDIRECTSTAINLESSBUFFERSTORE
£312.71
Capacity: 90L Solfex SOLDB090Height: 732mm CPS 132197Diameter: 550mm PTS SOLDB090Weight: 13kg empty / 103 kg full TP 132197Standing losses: 0.80kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS120LCASEDDIRECTSTAINLESSBUFFERSTORE
£343.71
Capacity: 120LHeight: 920mm Solfex SOLDB120Diameter: 550mm CPS 908460Weight: 18kg empty / 138 kg full PTS SOLDB120Standing losses: 1.00kWhr/24hr TP 908460Max working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS210LCASEDDIRECTSTAINLESSBUFFERSTORE
£415.19
Capacity: 210L Solfex SOLDB210Height: 1483 mm CPS 908463Diameter: 550mm PTS SOLDB210Weight: 28kg empty / 238 kg full TP 908463Standing losses: 1.60kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS300LCASEDDIRECTSTAINLESSBUFFERSTORE
£508.62
Capacity: 300L Solfex SOLDB300Height: 2020mm CPS 714402Diameter: 550mm PTS SOLDB300Weight: 37kg empty / 337 kg full TP 714402Standing losses: 1.93kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS400LCASEDDIRECTSTAINLESSBUFFERSTORE
£657.38
Capacity: 400L Solfex SOLDB400Height: 2030mm CPS 132196Diameter: 630mm PTS SOLDB400Weight: 51 kg empty / 451 kg full TP 132196Standing losses: 3.33kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)
74
Indirect Stainless Steel BuffersIndirect Stainless Buffer Stores
Description Part Code List PriceSOLFEXENERGYSYSTEMS120LCASEDINDIRECTSTAINLESSBUFFERSTORE
£453.52
Capacity: 120L Solfex SOLIB120Height: 920mm CPS 714393Diameter: 550mm PTS SOLIB120Weight: 22kg empty / 142 kg full TP 714393Standing losses: 1.00kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmCoil connections: 22mmCoil surface area: 0.59m²Thermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS210LCASEDINDIRECTSTAINLESSBUFFERSTORE
£547.21
Capacity: 210L Solfex SOLIB210Height: 1483 mm CPS 326257Diameter: 550mm PTS SOLIB210Weight: 33 kg empty / 243 kg full TP 326257Standing losses: 1.60kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 28mmHeat pump connections: 28mmCoil connections: 22mmCoil surface area: 0.78m²Thermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS300LCASEDINDIRECTSTAINLESSBUFFERSTORE
£662.46
Capacity: 300L Solfex SOLIB300Height: 2020mm CPS 908471Diameter: 550mm PTS SOLIB300Weight: 44 kg empty / 344 kg full TP 908471Standing losses: 1.93kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmCoil connections: 22mmCoil surface area: 0.78m²Thermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS400LCASEDINDIRECTSTAINLESSBUFFERSTORE
£754.68
Capacity: 400L Solfex SOLIB400Height: 2030mm CPS 908472Diameter: 630mm PTS SOLIB400Weight: 55 kg empty / 455 kg full TP 908472Standing losses: 3.33kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingCentral heating connections: 35mmHeat pump connections: 35mmCoil connections: 22mmCoil surface area: 0.78m²Thermostatic pockets: 2 (1x top & 1x bottom)
75
Multi-Tapping BuffersMulti-Tapping Stainless Buffer Stores
Description Part Code List PriceSOLFEXENERGYSYSTEMS90LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE
£384.73
Capacity: 90L Solfex SOLMB090Height: 740mm CPS 714405Diameter: 550mm PTS SOLMB090Weight: 13kg empty / 103 kg full TP 714405Standing losses: 0.80kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS120LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE
£418.56
Capacity: 120L Solfex SOLMB120Height: 930mm CPS 714392Diameter: 550mm PTS SOLMB120Weight: 18kg empty / 138 kg full TP 714392Standing losses: 1.00kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS210LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE
£496.62
Capacity: 210L Solfex SOLMB210Height: 1488 mm CPS 714395Diameter: 550mm PTS SOLMB210Weight: 28kg empty / 238 kg full TP 714395Standing losses: 1.60kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 28mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS250LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE
£574.50
Capacity: 250L Solfex SOLMB250Height: 1740 mm CPS 714399Diameter: 550mm PTS SOLMB250Weight: 32 kg empty / 282 kg full TP 714399Standing losses: 1.75kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS300LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE
£664.51
Capacity: 300L Solfex SOLMB300Height: 2025mm CPS 132195Diameter: 550mm PTS SOLMB300Weight: 37kg empty / 337 kg full TP 132195Standing losses: 1.93kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)
SOLFEXENERGYSYSTEMS400LCASEDDIRECTMULTI-TAPPINGSTAINLESSBUFFERSTORE
£744.60
Capacity: 400L Solfex SOLMB400Height: 2030mm CPS 326265Diameter: 630mm PTS SOLMB400Weight: 51 kg empty / 451 kg full TP 326265Standing losses: 3.33kWhr/24hrMax working pressure: 3.5bar store / 3.5bar space heatingConnections: 35mmThermostatic pockets: 2 (1x top & 1x bottom)
Energy ArenaUnits 3-5Charnley Fold Industrial EstateBamber BridgePrestonLancashirePR5 6PS
Tel: 01772 312 847Fax: 01772 335 277Email: [email protected]