alc plus
TRANSCRIPT
ALPDH Radio systems
Compact versionCompact plus version
User manual
MN.00142.E - 009Volume 1/1
The information contained in this handbook is subject to change without notice.
Property of Siae Microelettronica S.p.A. All rights reserved according to the law and according to the inter-national regulations. No part of this document may be reproduced or transmitted in any form or by anymeans, electronic or mechanical, without written permission from Siae Microelettronica S.p.A.
Unless otherwise specified, reference to a Company, name, data and address produced on the screen dis-played is purely indicative aiming at illustrating the use of the product.
MS-DOS®, MS Windows® are trademarks of Microsoft Corporation
HP®, HP OpenView NNM and HP–UX are Hewlett Packard Company registered trademarks.
UNIX is a UNIX System Laboratories registered trademark.
Oracle® is a Oracle Corporation registered trademark.
Linux term is a trademark registered by Linus Torvalds, the original author of the Linux operating system.Linux is freely distributed according the GNU General Public License (GPL).
Other products cited here in are constructor registered trademarks.
AL - MN.00142.E - 009 1
Components
Section 1.USER GUIDE 7
1 DECLARATION OF CONFORMITY ............................................................................... 7
2 FIRST AID FOR ELECTRICAL SHOCK AND SAFETY RULES .......................................... 8
2.1 FIRST AID FOR ELECTRICAL SHOCK..................................................................... 8
2.1.1 Artificial respiration .................................................................................. 8
2.1.2 Treatment of burns .................................................................................. 8
2.2 SAFETY RULES .................................................................................................10
3 PURPOSE AND STRUCTURE OF THE MANUAL............................................................11
3.1 PURPOSE OF THE MANUAL.................................................................................11
3.2 AUDIENCE BASIC KNOWLEDGE ..........................................................................11
3.3 STRUCTURE OF THE MANUAL .............................................................................11
Section 2.DESCRIPTIONS AND SPECIFICATION 13
4 LIST OF ABBREVIATIONS.........................................................................................13
5 SYSTEM PRESENTATION ..........................................................................................15
5.1 RADIO SYSTEM OVERVIEW ................................................................................15
5.1.1 General .................................................................................................15
5.2 COMPLIANCE WITH INTERNATIONAL STANDARDS ................................................15
5.3 APPLICATIONS .................................................................................................15
5.4 SYSTEM ARCHITECTURE....................................................................................16
5.4.1 IDU.......................................................................................................16
5.4.2 ODU......................................................................................................16
5.5 MANAGEMENT SYSTEMS....................................................................................17
5.5.1 Management ports ..................................................................................17
5.5.2 Protocols ...............................................................................................17
6 EQUIPMENT TECHNICAL SPECIFICATIONS...............................................................21
6.1 TECHNICAL SPECIFICATION...............................................................................21
2 AL - MN.00142.E - 009
7 CHARACTERISTICS OF THE INDOOR UNIT ...............................................................29
7.1 GENERAL.........................................................................................................29
7.2 TRAFFIC INTERFACE .........................................................................................29
7.2.1 2 Mbit/s Interface ...................................................................................29
7.2.2 Ethernet interface (optional).....................................................................30
7.3 SERVICE CHANNEL INTERFACE...........................................................................30
7.3.1 V.28 low speed synchronous/asynchronous data ........................................30
7.3.2 Alarm interface.......................................................................................30
7.3.3 64 kbit/s contra–directional interface V.11 (optional) ...................................30
7.3.4 Network Management Interface ................................................................31
7.4 MODULATOR/DEMODULATOR .............................................................................31
7.5 CABLE INTERFACE ............................................................................................32
7.6 AVAILABLE LOOPS ............................................................................................32
8 DESCRIPTION OF THE INDOOR UNIT – PDH INTERFACES ........................................33
8.1 1+0/1+1 IDU...................................................................................................33
8.1.1 Line interface .........................................................................................33
8.1.2 Radio interface .......................................................................................34
8.1.3 Equipment controller ...............................................................................35
8.2 IDU LOOPS ......................................................................................................36
8.2.1 Tributary loop........................................................................................36
8.2.2 Baseband unit loop .................................................................................36
8.2.3 IDU loop ...............................................................................................37
9 DESCRIPTION OF THE INDOOR UNIT – ETHERNET INTERFACES ..............................45
9.1 TREATMENT OF ETHERNET SIGNALS ...................................................................45
9.1.1 2 Mbit/s tributaries..................................................................................46
9.1.2 Electrical Ethernet interface.....................................................................46
9.1.3 Front panel LEDs of Ethernet ports ............................................................46
9.1.4 Bridge/switch function .............................................................................46
9.1.5 Ethernet Full Duplex function....................................................................47
9.1.6 Link Loss Forwarding ...............................................................................48
9.1.7 MDI/MDIX cross–over..............................................................................48
9.1.8 VLAN functionality...................................................................................48
9.1.9 Switch organized by port .........................................................................48
9.1.10 Switch organized by VLAN ID ...................................................................49
9.1.11 Layer 2, Priority function, QoS, 802.1p ......................................................50
10 CHARACTERISTICS OF THE OUTDOOR UNIT.............................................................54
10.1 GENERAL.........................................................................................................54
10.2 TECHNICAL SPECIFICATION...............................................................................54
11 DESCRIPTION OF THE OUTDOOR UNIT ....................................................................56
11.1 GENERAL.........................................................................................................56
11.2 TRANSMIT SECTION..........................................................................................56
11.3 RECEIVE SECTION ............................................................................................57
11.4 CABLE INTERFACE ............................................................................................57
11.5 ATPC OPERATION .............................................................................................57
11.6 1+1 Tx SYSTEM ...............................................................................................58
11.7 POWER SUPPLY ................................................................................................58
12 24/48 VOLT DC/DC CONVERTER D52089.................................................................63
AL - MN.00142.E - 009 3
12.1 GENERAL.........................................................................................................63
12.2 ENVIRONMENTAL CONDITIONS ..........................................................................63
12.3 ELECTRICAL CHARACTERISTICS .........................................................................63
Section 3.INSTALLATION 67
13 INSTALLATION AND PROCEDURES FOR ENSURING ELECTROMAGNETIC COMPATIBILITY ......................................................................................................67
13.1 GENERAL.........................................................................................................67
13.2 MECHANICAL INSTALLATION..............................................................................67
13.2.1 IDU installation.......................................................................................67
13.3 ELECTRICAL WIRING.........................................................................................68
13.4 GROUNDING CONNECTION ................................................................................69
14 ALC USER CONNECTIONS .........................................................................................70
14.1 CONNECTOR USE FOR 1+0/1+1 ALC VERSION .....................................................70
14.2 STANDARD VERSION CONNECTORS....................................................................71
15 ALC PLUS USER CONNECTIONS ................................................................................74
15.1 CONNECTOR USE FOR 1+0/1+1 ALC PLUS VERSION .............................................74
16 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA .............80
16.1 INSTALLATION KIT ...........................................................................................80
16.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) .............................................80
16.3 INSTALLATION PROCEDURE...............................................................................81
16.4 GROUNDING ....................................................................................................82
17 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA.............94
17.1 INSTALLATION KIT ...........................................................................................94
17.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) .............................................94
17.3 INSTALLATION PROCEDURE..............................................................................95
17.4 GROUNDING ....................................................................................................96
18 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA (KIT V52191, V52192)...........................................................................................105
18.1 FOREWORD ...................................................................................................105
18.2 INSTALLATION KIT .........................................................................................105
18.3 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ...........................................105
18.4 INSTALLATION PROCEDURE.............................................................................106
18.4.1 Installation onto the pole of the support system and the antenna ................106
18.4.2 Installation of ODU................................................................................107
18.4.3 ODU installation....................................................................................107
18.5 ANTENNA AIMING...........................................................................................108
18.6 GROUNDING ..................................................................................................108
19 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA (KIT V32307, V32308, V32309).............................................................................124
19.1 FOREWORD ...................................................................................................124
4 AL - MN.00142.E - 009
19.2 INSTALLATION KIT .........................................................................................124
19.3 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ...........................................125
19.4 INSTALLATION PROCEDURE.............................................................................125
19.5 1+0 MOUNTING PROCEDURES .........................................................................126
19.5.1 Setting antenna polarization...................................................................126
19.5.2 Installation of the centring ring on the antenna.........................................126
19.5.3 Installation of 1+0 ODU support .............................................................126
19.5.4 Installation onto the pole of the assembled structure .................................126
19.5.5 Installation of ODU (on 1+0 support).......................................................126
19.5.6 Antenna aiming ....................................................................................127
19.5.7 ODU grounding.....................................................................................127
19.6 1+1 MOUNTING PROCEDURES .........................................................................127
19.6.1 Installation of Hybrid .............................................................................127
19.6.2 Installation of ODUs (on hybrid for 1+1 version) .......................................128
20 INSTALLATION ONTO THE POLE OF THE 4 GHz ODU WITH SEPARATED ANTENNA (KIT V32323).........................................................................................................136
20.1 INSTALLATION KIT .........................................................................................136
20.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED) ...........................................136
20.3 INSTALLATION PROCEDURE.............................................................................136
Section 4.LINE-UP 143
21 LINE–UP OF THE RADIO HOP .................................................................................143
21.1 LINE–UP OF THE RADIO HOP............................................................................143
21.1.1 Antenna alignment and received field measurement ..................................143
21.1.2 Network element configuration ...............................................................144
21.1.3 Radio checks ........................................................................................144
22 LINE–UP OF ETHERNET TRAFFIC (FOR IDU WITH ETHERNET MODULE ONLY)........146
22.1 GENERAL.......................................................................................................146
22.2 LOCAL LAN–1 PORT TO REMOTE LAN–1 PORT (TRANSPARENT CONNECTION LAN PER PORT).....................................................................................................146
22.3 LOCAL LAN–1 PORT TO REMOTE LAN–1 PORT (WITH VLANs)................................151
22.4 3 TO 1 PORT CONNECTIONS ............................................................................154
22.5 3 TO 1 PORT CONNECTIONS, SETTINGS FOR UNTAGGED TRAFFIC ........................154
22.6 3 TO 1 PORT CONNECTIONS, SETTINGS FOR TAGGED AND UNTAGGED TRAFFIC ....157
22.7 3 TO 1 CONNECTIONS: EXAMPLES OF PRIORITY MANAGEMENT ............................158
Section 5.MAINTENANCE 163
23 PERIODICAL CHECKS .............................................................................................163
23.1 GENERAL.......................................................................................................163
AL - MN.00142.E - 009 5
23.2 CHECKS TO BE CARRIED OUT ..........................................................................163
24 TROUBLESHOOTING...............................................................................................164
24.1 GENERAL.......................................................................................................164
24.2 TROUBLESHOOTING PROCEDURE .....................................................................164
24.2.1 Loop facilities .......................................................................................164
24.2.2 Alarm messages processing....................................................................165
25 EQUIPMENT CONFIGURATION UPLOAD/SAVE/DOWNLOAD. PARAMETER MODIFICATION AND CREATION OF VIRTUAL CONFIGURATIONS. ..........................166
25.1 SCOPE ..........................................................................................................166
25.2 PROCEDURE...................................................................................................166
25.2.1 General equipment configuration............................................................166
25.2.2 Addresses and routing table ...................................................................167
25.2.3 Remote Element Table...........................................................................168
26 BACK UP FULL EQUIPMENT CONFIGURATION WITHOUT POSSIBILITY OF MODIFYING THE PARAMETERS .................................................................................................169
26.1 SCOPE ..........................................................................................................169
26.2 CONFIGURATION UPLOAD ...............................................................................169
26.3 CONFIGURATION DOWNLOAD ..........................................................................169
Section 6.PROGRAMMING AND SUPERVISION 171
27 PROGRAMMING AND SUPERVISION.......................................................................171
27.1 GENERAL.......................................................................................................171
Section 7.COMPOSITION 173
28 COMPOSITION OF THE INDOOR UNIT ....................................................................173
28.1 GENERAL.......................................................................................................173
28.2 ALC IDU PART NUMBER ...................................................................................173
28.3 ALC PLUS IDU PART NUMBER ...........................................................................174
29 COMPOSITION OF OUTDOOR UNIT.........................................................................175
29.1 GENERAL.......................................................................................................175
29.2 AL ODU .........................................................................................................175
29.3 AS ODU.........................................................................................................175
Section 8.
6 AL - MN.00142.E - 009
LISTS AND ASSISTANCE SERVICE 177
30 LIST OF FIGURES ...................................................................................................177
31 LIST OF TABLES .....................................................................................................181
32 ASSISTANCE SERVICE............................................................................................183
32.1 RQ.00961 MODULE .........................................................................................183
AL - MN.00142.E - 009 7
Section 1.USER GUIDE
1 DECLARATION OF CONFORMITY
SIAE Microelettronica S.p.A. declares that the products:
• Digital radio relay system AL7
• Digital radio relay system AL8
• Digital radio relay system AL11
• Digital radio relay system AL13
• Digital radio relay system AL15
• Digital radio relay system AL18
• Digital radio relay system AL23
• Digital radio relay system AL25
• Digital radio relay system AL28
• Digital radio relay system AL38
comply with the essential requirements of article 3 of the R&TTE Directive (1999/05/EC) and therefore ismarked CE.
The following standards apply:
• EN 60950 200 "Safety of information technology equipment".
• EN 301 489-4 V.1.3.1 (2002-8): "Electromagnetic compatibility and radio spectrum Matters (ERM);Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 4. Specificconditions for fixed radio links and ancillary equipment and services"
• ETSI EN 301 751 V.1.1. (2002-12): "Fixed Radio Systems; Point-to point equipment and antennas;generic harmonized standard for point-to-point digital fixed radio systems and antennas cov-ering the essential requirements under article 3.2 of the 1999/5/EC Directive".
8 AL - MN.00142.E - 009
2 FIRST AID FOR ELECTRICAL SHOCK AND SAFETY RULES
2.1 FIRST AID FOR ELECTRICAL SHOCK
Do not touch the patient with bare hands until the circuit has been opened. Open the circuit by switch-ing off the line switches. If that is not possible protect yourself with dry material and free the patientfrom the conductor.
2.1.1 Artificial respiration
It is important to start mouth resuscitation at once and to call a doctor immediately. Suggested procedurefor mouth to mouth resuscitation method is described in the Tab.1.
2.1.2 Treatment of burns
This treatment should be used after the patient has regained consciousness. It can also be employed whileartificial respiration is being applied (in this case there should be at least two persons present).
Warning
• Do not attempt to remove clothing from burnt sections
• Apply dry gauze on the burns
• Do not apply ointments or other oily substances.
AL - MN.00142.E - 009 9
Tab.1 - Procedure for mouth to mouth resuscitation method
Step Description Figure
1
Lay the patient on his back with his arms parallel to the body. If the patient is laying on an inclined plane, make
sure that his stomach is slightly lower than his chest. Open the patients mouth and check that there is no foreign mat-
ter in mouth (dentures, chewing gum, etc.).
2
Kneel beside the patient level with his head. Put an hand under the patient's head and one under his neck.
Lift the patient's head and let it recline backwards as far as possible.
3
Shift the hand from the patient's neck to his chin and his mouth, the index along his jawbone, and keep the other
fingers closed together. While performing these operations take a good supply of oxygen by taking deep breaths with
your mouth open.
4With your thumb between the patient's chin and mouth keep his lips together and blow into his nasal cavities.
5
While performing these operations observe if the patient's chest rises. If not it is possible that his nose is blocked: in that case open the patient's mouth as much as possible by pressing on his chin with your hand, place your lips around his mouth and blow into his oral cavity. Observe if the pa-tient's chest heaves. This second method can be used in-
stead of the first even when the patient's nose is not obstructed, provided his nose is kept closed by pressing the nostrils together using the hand you were holding his head with. The patient's head must be kept sloping back-
wards as much as possible.
6
Start with ten rapid expirations, hence continue at a rate of twelve/ fifteen expirations per minute. Go on like this until the patient has regained conscious-ness, or until a
doctor has ascertained his death.
10 AL - MN.00142.E - 009
2.2 SAFETY RULES
When the equipment units are provided with the plate, shown in Fig.1, it means that they contain compo-nents electrostatic charge sensitive.
Fig.1 - Components electrostatic charge sensitive
In order to prevent the units from being damaged while handling, it is advisable to wear an elasticised band(Fig.2) around the wrist ground connected through coiled cord (Fig.3).
Fig.2 - Elasticised band
Fig.3 - Coiled cord
The units showing the label, shown in Fig.4, include laser diodes and the emitted power can be dangerousfor eyes; avoid exposure in the direction of optical signal emission.
Fig.4 - Laser diodes
dezi
cits a
lE
dna
B
LASER
AL - MN.00142.E - 009 11
3 PURPOSE AND STRUCTURE OF THE MANUAL
3.1 PURPOSE OF THE MANUAL
The purpose of this manual consists in providing the user with information which allows to operate andmaintain the ALC radio family.
Warning: This manual does not include information relevant to the SCT/LCT management program win-dows and relevant application. They will provided by the program itself as help-on line.
3.2 AUDIENCE BASIC KNOWLEDGE
The following knowledge and skills are required to operate the equipment:
• a basic understanding of microwave transmission
• installation and maintenance experience on digital radio system
• a good knowledge of IP/OSI networks and routing policy.
3.3 STRUCTURE OF THE MANUAL
The manual is subdivided into sections each of them developing a specific topic entitling the section.
Each section consists of a set of chapters, enlarging the main subject master.
Section 1 - User Guide
It provides the information about the main safety rules and expounds the purpose and the structure of themanual.
Section 2 - Description and specifications
It traces the broad line of equipment operation and lists the main technical characteristics of the wholeequipment and units it consists of.List of abbreviation meaning is also supplied.
Section 3 - Installation
The mechanical installation procedures are herein set down as well as the user electrical connec-tions.The content of the tool kit (if supplied) is also listed.
12 AL - MN.00142.E - 009
Section 4 - Line-Up
Line-up procedures are described as well as checks to be carried out for the equipment correct operation.The list of the instruments to be used and their characteristics are also set down.
Section 5 - Maintenance
The routine maintenance actions are described as well as fault location procedures in order to identify thefaulty unit and to re-establish the operation after its replacement with a spare one.
Section 6 - Programming and supervision
The ALC radio family is programmed and supervised using different software tools. Some of them are al-ready available, some other will be available in the future.
This section lists the tools implemented and indicates if descriptions are already available. Each descriptionof software tools is supplied in a separated manual.
Section 7 - Composition
Position, part numbers of the components the equipment consist of, are shown in this section.
Section 8 - Lists and assistance service
It provides the lists of figures ans tables and the assistance service.
AL - MN.00142.E - 009 13
Section 2.DESCRIPTIONS AND SPECIFI-CATION
4 LIST OF ABBREVIATIONS
- AF Assured Forwarding
- ALC Access Link Compact Version
- ALC plus Access Link Compact Plus Version
- AIS Alarm Indication Signal
- ATPC Automatic Transmit Power Control
- BB Baseband
- BBER Background Block Error Radio
- BER Bit Error Rate
- DSCP Differentiated Service Code Point
- DSP Digital Signal Processing
- EMC/EMI Electromagnetic Compatibility/Electromagnetic Interference
- EOC Embedded Overhead Channel
- ERC European Radiocommunication Committee
- ESD Electrostatic Discharge
- FEC Forward Error Corrector
- FEM Fast Ethernet Module
- HDLC High Level Data Link Control
- IDU Indoor Unit
- IF Intermediate Frequency
- IpToS Type of Service IP
- LAN Local Area Network
- LAPS Link Access Procedure SDH
14 AL - MN.00142.E - 009
- LCT Local Craft Terminal
- LIM Line Interface Module
- LLF Link Loss Forwarding
- LOF Loss Of Frame
- LOS Loss Of Signal
- MAC Media Access Control
- MDI Medium Dependent Interface
- MDIX Medium Dependent Interface Crossover
- MIB Management Information Base
- MMIC Monolitic Microwave Integrated Circuit
- MTBF Mean Time Between Failure
- NE Network Element
- ODU Outdoor Unit
- OSI Open System Interconnection
- PDH Plesiochronous Digital Hierarchy
- PPI Plesiochronous Physical Interface
- PPP Point to Point Protocol
- PTOS Priority Type Of Service
- RIM Radio Interface Module
- SCT Subnetwork Craft Terminal
- SNMP Simple Network Management Protocol
- TCP/IP Transmission Control Protocol/Internet Protocol
- TOS Type Of Service
- VID Virtual LAN Identifier
- VLAN Virtual LAN
- WFQ Wait Fair Queue
- Wayside Traffic Additional 2 Mbit/s Traffic
AL - MN.00142.E - 009 15
5 SYSTEM PRESENTATION
5.1 RADIO SYSTEM OVERVIEW
5.1.1 General
AL is SIAE's PDH radio series for low-to-medium transmission capacities in frequency bands from 7 to 38GHz.
Different hardware versions offer a range of tributaries traffic from 2xE1 to 32xE1, with or without Ethernettraffic, on 4QAM, 16QAM and 32QAM modulation, with capacity up to 105 Mbit/s.
Reduced cost, high reliability, compact size, light weight and full programmability are the key features ofthis radio series.
5.2 COMPLIANCE WITH INTERNATIONAL STANDARDS
The equipment complies with the following international standards:
• EN 301 489-4 for EMC
• ITU-R recommendations for all frequency bands
• EN 300 132-2 characteristics for power supply
• EN 300 019 environmental characteristics (Operation class 3.2 for IDU and class 4.1 for ODU; stor-age: class 1.2; transport: class 2.3)
• EN 60950 for safety.
5.3 APPLICATIONS
AL main applications are:
• radio communication between GSM cells
• radio links for voice and data transmission
• spur routes for high capacity radio system
• emergency links
• Ethernet traffic in point to point communication.
16 AL - MN.00142.E - 009
5.4 SYSTEM ARCHITECTURE
The AL radio equipment consist of two separate units:
• the indoor unit (IDU) that houses tributary interfaces, Ethernet ports modem and controllerunits
• the outdoor unit (ODU) that converts IF signals into RF signals and vice versa.
The two units are interconnected via coaxial cable. Fig.5 and Fig.6 show a typical IDU/ODU layout whereasFig.7 and Fig.8 show the radio block diagram in 1+0 and 1+1 configuration respectively.
5.4.1 IDU
The IDU is available in the following hardware versions:
• ALC
- 1 rack unit compact IDU, 1+0 configuration, 2/4/8 E1
- 1 rack unit compact IDU, 1+0 configuration, 2/4/8/16 E1
- 1 rack unit compact IDU, 1+1 configuration, 2/4/8 E1
- 1 rack unit compact IDU, 1+1 configuration, 2/4/8/16 E1
• ALC plus
- 1 rack unit compact plus IDU, 1+0 configuration, 2/4/5/8/10/16 E1
- 1 rack unit compact plus IDU, 1+1 configuration, 2/4/5/8/10/16 E1
- 1 rack unit compact plus IDU, 1+0 configuration, 2/4/5/8/10/16/20/32 E1
- 1 rack unit compact plus IDU, 1+0 configuration, 2/4/5/8/10/16/20/32 E1
Ethernet module can be housed inside IDU, as option, for Ethernet traffic. ALC and ALC plus IDUs consistof a single circuit board plugged into a wired shelf. Line interfaces house tributary connections and, througha multiplexing/demultiplexing and bit insertion/extraction process, supply/receive the aggregate signalto/from the modulator/demodulator.
Main difference between ALC IDU and ALC plus IDU is the increased capacity (up to 32E1 and up to 105Mbit/s of total capacity) and the possibility to use the bandwidth of transmitted channel more efficiently:5 E1 streams can be transmitted in the bandwidth previously used by 4 E1 only, 10 E1 streams can betransmitted in the bandwidth previously used by 8 E1 only, 20 E1 streams can be transmitted in the band-width previously used by 16 E1 only.
Line interfaces carry out the digital processing for the QAM modulator and, in 1+1 configuration, duplicatethe main signals on the transmission side and perform the changeover on the receive side. Interfaces to-wards the ODU house the cable interface for bidirectional communication between ODU and IDU, and im-plement the IF section of the mo-demodulator.
IDU power supply units process battery voltage and supply power to IDU and ODU circuits. The controllersection of the radio houses service channels interfaces, stores IDU firmware, interfaces SIAE man-agement systems though dedicated supervision ports, and routes external and internal alarms to relaycontacts.
5.4.2 ODU
The ODU houses the interface towards the IDU on one side, and towards the antenna flange on the other.The ODU shifts the incoming QAM-modulated carrier to RF frequency through a double conversion. Theopposite occurs at the receive side, when the IF-converted carrier is sent to the IDU demodulator.Antenna coupling in 1+1 systems is done through a balanced or unbalanced hybrid.
Two versions of ODU are available, ODU AL and ODU AS; they differ in output power.
AL - MN.00142.E - 009 17
5.5 MANAGEMENT SYSTEMS
AL radio can be controlled locally and remotely via SIAE supervision software:
• SCT/LCT: a Windows-based management system for small networks (up to 100 NE)
• NMS5-LX: a Linux-based management system for small-to-medium networks (up to 750 NE)
• NMS5-UX: a Unix-based management system for large networks (up to 2500 NE)
These systems provide a friendly graphic interface complying with current standard use of keyboards,mouse and windows.
5.5.1 Management ports
AL radio terminals connect to the supervision network via the following communication ports:
• Ethernet 10BaseT Port (2 port in ALC plus)
• USB port
5.5.2 Protocols
SNMP along with IP or OSI protocol stacks are used to manage AL operation.
Fig.5 - 1+1 ODU typical configuration with integrated antenna
18 AL - MN.00142.E - 009
Fig.6 - 1+1 IDU typical configuration
10/1
00 B
TX
32
1ACT
LIN
KD
PLX
DPL
XLI
NK
ACT
ACT
LIN
KD
PLX
21RX
TX
AL
TEST
RPS
2
PS1
21
21
48V2
+
––
+
48V1
Q3
LCT
USER I
N/O
UT
12
34
56
78
910
1112
13
14
15
16
1
1 22
RS23
2V11
Q3/
2Q
3/1
LCT
USER
IN
/OU
T
RX
TX1 2
TEST AL
R
Trib
. 1-
8Tr
ib.
9-16
Trib
. 25
-32
Trib
. 17
-24
21
+
--
+
48VD
C48
VD
C
PS
12
250V
AC
M3.
15A
3.15
AM
250V
AC
10/1
00 B
aseT
12
3ACT
LIN
K
DPX
ALC
16E1 +
Eth
ernet
ALC
plu
s 3
2E1 +
Eth
ernet
AL - MN.00142.E - 009 19
Fig.7 - 1+1 equipment block diagram
ciffart niaM
ELB
AC
.FR
ETNI
1 U
DO
RELL
ORT
NO
C
secivreS
ELB
AC
.FR
ETNI
2 U
DO
RELL
ORT
NO
C
2 ec af re tnI oi daR
NIA
M
RELL
ORT
NO
C
LO
RTN
OC
UDI
ti nU rel lo rt no
C
UDI
ELB
AC
ELB
AC
.FR
ETNI
1
1xT
1xR
1 U
DO
WS
.RT
NO
C
2xT
2xR
2 U
DO
WS
.RT
NO
C
ELB
AC
XU
M
XU
ME
D
B d 4ro
Bd 5.7/5.1
ciffart niaM
ELB
AC
.FR
ETNI
2
DO
M
ME
D
TC L/ T
CS
LO
R TN
OC
UD
O
MR
ALA
IB
PS
D
PS
D
FI FI
eca fretn I en iL
.TTAB
DO
M
ME
D
. TT AB
PS
D
V 84
V 84
secivreS
DO
M
ME
D
ME
D
EB
FI FI
1 ecafretnI oidaR
20 AL - MN.00142.E - 009
Fig.8 - 1+0 non expandable equipment block diagram
ciffart niaM
ELB
AC
.FR
ETNI
UD
OR
ELLO
RTN
OC
secivreS
NIA
M
RELL
ORT
NO
C
LO
R TN
OC
UDI
ELB
AC
ELB
AC
.FR
ETNI
1
1xT
1xR
UD
O
WS
.RT
NO
CX
UM
XU
ME
Dciffart nia
M
DO
M
ME
D
TCL/ T
CS
LO
RTN
OC
UD
O
MR
A LA
IB
PS
D
PS
D
FI FI
.TTAB
V 84
s ecivreS
DO
M
ME
D
EB
UDI
AL - MN.00142.E - 009 21
6 EQUIPMENT TECHNICAL SPECIFICATIONS
6.1 TECHNICAL SPECIFICATION
- Frequency range
- 7 GHz 7.11 to 7.7 GHz
- 8 GHz 7.7 to 8.5 GHz
- 11 GHz 10.7 to 11.7 GHz
- 13 GHz 12.75 to 13.25 GHz
- 15 GHz 14.4 to 15.35 GHz
- 18 GHz 17.7 to 19.7 GHz
- 23 GHz 21.2 to 23.6 GHz
- 25 GHz 24.5 to 26.5 GHz
- 28 GHz 27.5 to 29.5 GHz
- 38 GHz 37 to 39.5 GHz
- RF channel arrangement
- 7 GHz ITU-R Rec F.385
- 8 GHz ITU-R Rec F.386
- 11 GHz no ITU-R Rec. for PDH 11 GHz band
- 13 GHz ITU-R Rec F.497
- 15 GHz ITU-R Rec F.636
- 18 GHz ITU-R Rec F.595
- 23 GHz ERC/T/R 13-02 Annex A or ITU-R Rec F.637
- 25 GHz ERC/T/R 13-02 Annex B
- 28 GHz ERC/T/R 13-02 Annex C
- 38 GHz ITU-R Rec F.749
- Go-return frequency
- 7 GHz 245/196/168/161/154 MHz
- 8 GHz 311.32 MHz
- 11 GHz 530 MHz
- 13 GHz 266 MHz
- 15 GHz 420/728 MHz
- 18 GHz 1010 MHz
- 23 GHz 1008/1232 MHz
- 25 GHz 1008 MHz
- 28 GHz 1008 MHz
- 38 GHz 1260 MHz
22 AL - MN.00142.E - 009
- Transmission capacity see Tab.2
Tab.2 Signal capacity
- Service channel capacity:
- 64 kbit/s V11 co/contradirectional interface or V28 (1x9600 or 2x4800 baud)
- RS232 PPP for supervision
- EOW external module (optional) connected to V11 and RS232 ports
- Antenna configuration 1+0 or 1+1 hot stand-by and 1 antenna, 1+1 frequency diversity on 1 cross polar antennaor two separated antennas
- Frequency accuracy ± 5 ppm; ± 10 ppm ageing included
- RF spurious emissions according to ETSI EN 301 390
- Modulation 4QAM/16QAM/32QAM (ALC plus only), see Tab.3
Tab.3 - Modulation and channel spacing
- Demodulation coherent
- Output power at the antenna side, 1+0 version refer to Tab.4
- Receiver threshold at the antenna side 1+0 version refer to Tab.5 and Tab.6
- Additional losses both Tx and Rx sides, 1+1 version
- 4 dB ± 0.5 dB version with balanced hybrid
- ≤ 1.7 dB (branch 1) / ≤ 7 dB (branch 2) version with unbalanced hybrid
- Residual BER 1x10-11
- Maximum input level for BER 10-3 -20 dBm
IDU type Capacity Configuration
ALC 2/4/8 E1 (max 16 Mbit/s) 1+0/1+1
ALC 2/4/8/16 E1 (max 32 Mbit/s) 1+0/1+1
ALC 2/4/8/16 E1 + 3x10/100BaseT (max 32 Mbit/s) 1+0/1+1
ALC 2/4/8/16 E1 + 3x10/100BaseT (max 64 Mbit/s) 1+0/1+1
ALC plus 2/4/5/8/10/16 E1 (max 32 Mbit/s) 1+0/1+1
ALC plus 2/4/5/8/10/16/20/32 E1 (max 64 Mbit/s) 1+0/1+1
ALC plus 2/4/5/8/10/16/20/32 E1 + 3x10/100BaseT (max 64 Mbit/s) 1+0/1+1
ALC plus 2/4/5/8/10/16/20/32 E1 + 3x10/100BaseT (max 105 Mbit/s) 1+0/1+1
ModulationCapacity
4 Mbit/s 8 Mbit/s 16 Mbit/s 32 Mbit/s 64 Mbit/s 105 Mbit/s
4QAM 3.5 MHz 7 MHz 14 MHz 28 MHz - -
16QAM - 3.5 MHz 7 MHz 14 MHz 28 MHz -
32QAM (ALC plus) - - - - - 28 MHz
AL - MN.00142.E - 009 23
Tab.4 - Nominal output power 1 dB tolerance - (1+0 version) ODU AL/ODU AS
Tab.5 - Guaranteed received threshold in 1+0 configuration (dBm)
Tab.6 - Guaranteed received threshold in 1+0 configuration (dBm)
GHz Output power 4QAM Output power 16QAM Output power 32QAM
7 +27/30 dBm +22/26 dBm +20/n.a. dBm
8 +27/30 dBm +22/26 dBm +20/n.a. dBm
11 +25/29 dBm +20/25 dBm -
13 +25/29 dBm +20/25 dBm +20/n.a. dBm
15 +25/28 dBm +20/24 dBm +20/n.a. dBm
18 +20/24 dBm +15/20 dBm +15/20 dBm
23 +20/23 dBm +15/19 dBm +15/19 dBm
25 +20/23 dBm +15/19 dBm +15/19 dBm
28 +19/22 dBm +14/18 dBm +14/18 dBm
32 +17/20 dBm +13/16 dBm +13/16 dBm
38 +17/20 dBm +13/16 dBm +13/16 dBm
GHz
4QAM 16QAM
2x2 4x2 2x2 4x2
10-6 10-3 10-6 10-3 10-6 10-3 10-6 10-3
7 -91 -93 -88 -90 - - -84 -86
8 -91 -93 -88 -90 - - -84 -85
11 -90.5 -92.5 -87.5 -89.5 - - -83.5 -85.5
13 -90.5 -92.5 -87.5 -89.5 -83.5 -85.5
15 -90.5 -92.5 -87.5 -89.5 - - -83.5 -85.5
18 -90 -92 -87 -89 - - -84 -86
23 -90 -92 -87 -89 - - -83 -85
25 -89.5 -91.5 -86.5 -88.5 - - -82.5 -84.5
28 -89 -91 -86 -88 - - -82 -84
38 -88 -90 -85 -88 - - -81 -83
GHz
4QAM 16QAM 32QAM
8x2 16x2 8x2 16x2 32x2 100
10–6 10–3 10–6 10–3 10–6 10–3 10–6 10–3 10–6 10–3 10–6 10–3
7 –85 –87 –82 –84 –81 –83 –78 –80 –75 –77 –72 –74
8 –85 –87 –82 –84 –81 –83 –78 –80 n.a. n.a. n.a. n.a.
11 –84.5 –86.5 –81.5 –83.5 –80.5 –82.5 –77.5 –79.5 –74.5 –76.5 –71.5 –73.5
13 –84.5 –86.5 –81.5 –83.5 –80.5 –82.5 –77.5 –79.5 –74.5 –76.5 –71.5 –73.5
15 –84.5 –86.5 –81.5 –83.5 –80.5 –82.5 –77.5 –79.5 –74.5 –76.5 –71.5 –73.5
18 –84 –86 –81 –83 –80 –82 –77 –79 –74 –76 –71 –73
23 –84 –86 –81 –83 –80 –82 –77 –79 –73 –75 –70 –72
25 –83.5 –85.5 –80.5 –82.5 –79.5 –81.5 –76.5 –78.5 –72.5 –74.5 –69.5 –71.5
28 –83 –85 –80 –82 –79 –81 –76 –78 –72 –74 –69 –71
32 -82 -84 -80 -81 -78 -80 -75 -77 -72 -74 -69 -71
38 –82 –84 –80 –81 –78 –80 –75 –77 –71 –73 –68 –70
24 AL - MN.00142.E - 009
- Power supply voltage -40.8 to -57.6 Vdc
- Power consumption Fully equipped terminal with 370 m 1/4" IDU/ODUcable (refer to Tab.7).
Tab.7 - Power consumption (ODU AL/ODU AS)
- Power supply connector consumption (refer to Tab.8)
Tab.8 - Power supply connector consumption
- Fuse 3.15 A (M), 5x20 mm on front panel
- Environmental conditions
- Operational range for IDU –5° C to +45° C
- Operational range for ODU –33° C to +55° C
- Survival temperature range for IDU –10° C to +55° C
- Survival temperature range for ODU –40° C to +60° C
- Operational humidity for IDU 95% at +35° C
- Operational humidity for ODU weather proof according to IP65 environmental class
- Heat dissipation of ODU Thermal resistance 0.5° C/WSolar heat gain: not exceeding 5° C
- Wind load ≤ 260 Km/h
- Mechanical characteristics
- Dimensions refer to Tab.9
Tab.9 - IDU/ODU dimensions
- Weight refer to Tab.10
Tab.10 - IDU/ODU weight
ConfigurationGuaranteed power consump-
tion (IDU) f≤15 GHz -40.8 to -57.6 Vdc
Guaranteed power consump-tion (IDU) f>15 GHz
-40.8 to -57.6 Vdc
1+0 ≤ 32W/34W ≤ 25W/34W
1+1 ≤ 52W/62W ≤ 40W/62W
Guaranteed consumptionf≤15 GHz da - 40.8 Vdc
Guaranteed consumptionf>15 GHz da –40.8 Vdc
≤ 1 A ≤ 1 A
Width(mm)
Height(mm)
Depth(mm)
ODU AL/ODU AS 1+0 250/255 255/255 100/121
ODU AL/ODU AS 1+1 278/358 255/255 280/280
IDU 1+0/1+1 480 45 260
ODU AL/ODU AS 1+0 4.5/5.5 Kg
ODU AL/ODU AS 1+0 13.3/15.5 Kg
IDU 1+0/1+1 3.5/3.7 Kg
Panning system 1+0/1+1 4.4 Kg
AL - MN.00142.E - 009 25
- Mechanical layout refer to typical Fig.9, Fig.10, Fig.11, Fig.12 andFig.13.
Fig.9 - IDU ALC 1+0 (2/4/8xE1)
Fig.10 - IDU ALC 1+1 (2/4/8/16xE1)
Fig.11 - IDU ALC 1+1 (up to 16xE1 coax. conn.) + Ethernet
Fig.12 - IDU ALC plus 1+1 (2/4/5/8/10/16/20/32xE1)
Fig.13 - IDU ALC plus 1+1 (2/4/5/8/10/16/20/32xE1) + Ethernet
48V
+ –
Trib. 1–2–3–4
Trib. 5–6–7–8
PSLCTQ3 USER IN/OUT
RTESTAL
21
RXTX
ALTEST
R
USER IN/OUTQ3 LCT
PS2
PS1
Trib. 13–14–15–16Trib. 5–6–7–8
Trib. 9–10–11–12Trib. 1–2–3–4
2121
48V2
+ ––+
48V1
10/100 BTX
321ACTLINK
DPLXDPLXLINKACTACT
LINKDPLX
21
RXTX
ALTEST
RPS2
PS12121
48V2+ ––+48V1Q3 LCT USER IN/OUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
21
48VDC248VDC1
+ --+
1 2
Trib. 17-24 Trib. 25-32
Trib. 9-16Trib. 1-8
R AL
TEST
2
1TX RX
USER IN/OUTLCTQ3/1Q3/2
V11 RS232
3.15AM250VAC 250VAC
M 3.15A
PS1
2
1
12 2
RS232V11
Q3/2 Q3/1 LCT USER IN/OUT
RXTX12
TESTALR
Trib. 1-8 Trib. 9-16
Trib. 25-32Trib. 17-24
21
+ - -+48VDC 48VDC
PS
1 2
250VACM 3.15A3.15AM 250VAC
10/100 BaseT
1 2 3ACT LINK
DPX
26 AL - MN.00142.E - 009
Fig.14 - IDU 1+1 (up to 16x2 Mbit/s coax. conn.) + Ethernet module
Fig.15 - 1+1 ODU with separated antenna
AL - MN.00142.E - 009 27
Fig.16 - 1+0 ODU with integral antenna (pole mounting)
Fig.17 - 1+1 ODU with integral antenna (pole mounting)
28 AL - MN.00142.E - 009
Fig.18 - 1+1 ODU with separated antenna (wall mounting)
AL - MN.00142.E - 009 29
7 CHARACTERISTICS OF THE INDOOR UNIT
7.1 GENERAL
The following IDU characteristics are guaranteed for the temperature range from –5° C to +45° C.
7.2 TRAFFIC INTERFACE
7.2.1 2 Mbit/s Interface
Input side
- Bit rate 2048 kbit/s ± 50 ppm
- Line code HDB3
- Rated impedance 75 Ohm or 120 Ohm
- Rated level 2.37 Vp/75 Ohm or 3 Vp/120 Ohm
- Return loss 12 dB from 57 kHz to 102 kHz18 dB from 102 kHz to 2048 kHz14 dB from 2048 kHz to 3072 kHz
- Max attenuation of the input cable 6 dB according to √ f trend
- Accepted jitter see mask in Table 2, CCITT Rec. G.823
- Transfer function see mask in Figure 1, CCITT Rec. G.742
- Connector type SUB-D, 25 pins
Output side
- Bit rate 2048 kbit/s ± 50 ppm
- Rated impedance 75 Ohm or 120 Ohm
- Rated level 2.37 Vp/75 Ohm or 3 Vp/120 Ohm
- Output jitter in accordance with G.742/G.823
- Pulse shape see mask in Figure 15, CCITT Rec. G.703
- Connector type SUB-D, 25 pins
30 AL - MN.00142.E - 009
7.2.2 Ethernet interface (optional)
RJ45 interface
- LAN type Ethernet Twisted Pair 802.3 10BaseT/100BaseT
- Connector RJ45
- Connection to LAN direct with a CAT5 Twisted Pair
- Protocol TCP/IP or IPoverOSI
7.3 SERVICE CHANNEL INTERFACE
7.3.1 V.28 low speed synchronous/asynchronous data
- Data interface RS232
- Electrical interface CCITT Rec. V.28
- Input speed 9600 baud
- Control wires DTR, DSR, DCD
7.3.2 Alarm interface
User output
- Relay contacts normally open (NO) or normally closed (NC)
- Open contacts Rmin 100 MOhm at 500 Vdc
- Open contacts Rmax 0.5 Ohm
- Switching voltage Vmax 100 V
- Switching current Imax 1A
User input
- Equivalent circuit recognised as a closed contact 200 Ohm resist. (max) referred to ground
- Equivalent circuit recognised as an open contact 60 kOhm (min) referred to ground
7.3.3 64 kbit/s contra–directional interface V.11 (optional)
- Tolerance ±100 ppm
- Equipment side contra–directional
AL - MN.00142.E - 009 31
- Coding clock and data on independent wires
- Electrical interface see Rec. CCITT V.11
7.3.4 Network Management Interface
RJ45 interface
- LAN type Ethernet Twisted Pair 802.3 10BaseT/100BaseT
- Connector RJ45
- Connection to LAN direct with a CAT5 Twisted Pair
- Protocol TCP/IP or IPoverOSI
LCT USB interface
- Electrical interface USB 1.1 version
- Baud rate 1.5 Mbit/s
- Protocol PPP
RS232 interface (optional)
- Electronic interface V.28
- Asynchronous baud rate 9600, 19200, 38400, 57600
- Protocol PPP
7.4 MODULATOR/DEMODULATOR
- Carrier modulating frequency
- Tx side 330 MHz
- Rx side 140 MHz
- Type of modulatioln 4QAM/16QAM
- Spectrum shaping from 4 Mbit/s to 34 Mbit/s depending on differentversions
- Forma dello spettro raised cosine (roll–off = 0.5)
- Equalization 5 tap
- FEC coding gain 2.5 dB at 10–6
32 AL - MN.00142.E - 009
7.5 CABLE INTERFACE
- Interconnection with the ODU unit single coaxial cable for both Tx and Rx
- Cable length up to 370 m. with 1/4" cable type
- Rated impedance 50 Ohm
- Signal running along the cable
- Tx nominal frequency 330 MHz
- Rx nominal frequency 140 MHz
- Transceiver management signals 388 kbit/s bidirectional
- Carrier for transceiver management signals IDU at ODU = 17.5 MHz/0 dBmODU at IDU = 5.5 MHz/0 dBm
- Remote power supply direct from battery voltage
7.6 AVAILABLE LOOPS
The following loop are available within the IDU:
- Tributary loop
- Baseband loop
- IDU loop
AL - MN.00142.E - 009 33
8 DESCRIPTION OF THE INDOOR UNIT – PDH IN-TERFACES
8.1 1+0/1+1 IDU
The following functional description covers the versions the IDU consists of as shown in chapter "Equip-ment technical specifications".
The IDU is made up of a single motherboard that houses all the circuitry realizing the following function-alities:
• Line interface
• Radio interface
• Equipment controller
• IDU loops.
The different versions of IDU are pointed out in following description only if it is necessary.
8.1.1 Line interface
The line interface performs the following operations:
• multiplexing process of the input tributaries
• generation of the aggregate frame by aggregating multiplexed tributaries and service channel.
Bit extraction and demultiplexing process happens at the receive side.
Tx side
Refer to Fig.19. The 2 Mbit/s input signal is code converted from HDB3 to NRZ format before being multi-plexed. The multiplexing scheme depends on the number and the bit rate of the input tributaries. Attachedfigures show different multiplexing scheme as follows:
• Fig.20 – 2x2 Mbit/s multiplexing. The mux performs stuffing operation on each single tributary andgenerates a proprietary frame embedding the two tributaries to be sent to the Bit Insertion. Oppo-site operation occurs at the Rx side.
• Fig.21 – 4x2 Mbit/s multiplexing. The mux aggregates the four 2 Mbit/s tributaries generating a8448 kbit/s frame as per Recc. G.742. The multiplexed signal is then sent to the Bit Insertion. Op-posite operation occurs at the Rx side.
• Fig.22 – 8x2 Mbit/s multiplexing. The eight 2 Mbit/s tributaries are grouped in two 4x2 Mbit/s groupseach of one generating a G742 frame structure at 8448 kbit/s to be sent to the next Bit Insertion.Opposite operation occurs at the Rx side.
• Fig.23 – 16x2 Mbit/s multiplexing. The sixteen 2 Mbit/s tributaries are grouped in four 4x2 Mbit/sgroups each of one generating a G.742 frame structure at 8448 kbit/s. A further multiplexing of theachieved four 8448 kbit/s streams will generate a frame structure at 34368 kbit/s as per Recc.G.751. This latter is to be sent to the Bit Insertion. Opposite operation occurs at the Rx side.
The multiplexed tributaries are then sent to the B.I. for aggregate frame generation.
The aggregate frame contains:
34 AL - MN.00142.E - 009
• the main signal from the MUX(s)
• the framed service signal from the service interface
• the EOC signals for supervision message propagation towards the remote terminal
• the frame alignment word
• the bits dedicated to the FEC.
All the synch. signals to perform multiplexing (demultiplexing) and BI (BE) process are achieved from a x0at 40 MHz. The aggregate frame thus generates is sent to the QAM modulator.
Rx side
Refer to Fig.24.
At Rx side the Bit extraction separates the main multiplexed signal from the service signal and then aftera proper demultiplexing process (opposite to that previously described at the Tx side) sends them to theoutput interfaces.
8.1.2 Radio interface
This functionality provides the following:
• QAM modemodulation
• power supply to IDU and ODU
• telemetry IDU/ODU
• cable interface
QAM modemodulation – Modulation side
See Fig.25
The aggregate signal from the BI undergoes the following process in digital form:
• serial to parallel conversion
• differential encoding
• generation of the shaped modulating signals feeding the IF part of the QAM modulator.
This latter comprises:
• recovery low pass filter to eliminate signal periodicity
• 330 MHz local oscillator
• a 90° phase shifter to supply two mixers with two in quadrature carriers
The thus obtained 330 MHz QAM modulated carrier is then sent to the cable interface for connection withODU.
QAM modemodulation – Demodulation side
See Fig.25.
The 140 MHz modulated carrier from the ODU is reaching the IDU through the cable interface.
The connection to the demodulator input is made via a cable equalizer for cable loss compensation.
The IF section of the QAM demodulator extracts the I and Q analogue signals then digital converted for thefollowing processing:
• clock recovery
AL - MN.00142.E - 009 35
• baseband equalisation and filtering
• bit polarity decision
• differential decoding
• parallel to serial conversion to recover the aggregate signal.
The aggregate signal is then sent to a frame alignment circuit and CRC analysis and then to the error cor-rector to achieve the BER extimate, the PM and HBER/LBER alarms.
Power supply
Refer to Fig.25. The –48 V battery voltage feeds the IDU and ODU circuitry. The service voltages for theIDU feeding are achieved through a DC/DC converter for +3.6 V generation and a step down circuit for –5V.
Both voltages are protected against overvoltages and overcurrents. The power to the ODU is given by thesame battery running through the interconnection cable. A breaker protects the battery against cable fail-ure.
Telemetry IDU/ODU
Refer to Fig.19 and Fig.25. The dialogue IDU/ODU is made–up by the main controller and associated pe-ripherals within the ODU. Controls for ODU management and alarm reporting is performed making use ofa 388 kbit/s framed signals. The transport along the interconneting cable is performed via two FSK mod-ulated carriers: 17.5 MHz from IDU to ODU; 5.5 MHZ from ODU to IDU.
Cable interface
Refer to Fig.25. This circuit permits to communicate to the far ODU through the interconnecting cable. Itis mainly made up of a set of filters that:
• combine the 330 MHz, QAM modulated carrier/the 17.5 MHz carrier/the power supply
• separate the 140 MHz QAM modulated carrier and the 5.5 MHz carrier
8.1.3 Equipment controller
The controller functionality performs the following:
• houses the equipment software for equipment management
• interfaces the SCT/LCT program through supervision ports
• receive external alarms and route them to relay contacts along with the internal alarms generatedby the equipment.
The equipment software permits to control and manage all the equipment functionality. It is distributed ontwo hardware levels: main controller and ODU peripheral controller. The dialogue between main and pe-ripheral controllers is shown in Fig.26.
Main controller
The activities executed by the main controller are the following:
• Communication management: it makes use of SNMP as management protocol and IP or IP over OSIas communication protocol stacks. See Fig.27 for details. The interface ports for the equipmentmanagement are the following:
- LAN Ethernet 10BaseT
- USB port used for SCT/LCT connection
36 AL - MN.00142.E - 009
- EOC embedded within the PDH radio frame for connection to the remote NEs
• Log–in: the main controller manages the equipment or network login/logout by setting and thencontrolling the user’s ID and relevant password.
• Database (MIB): validation and storing in a non–volatile memory of the equipment configurationparameters.
• Equipment configuration: distribution of the parameters stored in the MIB towards the peripheralµPs for their attuation in addition to the controls from user not stored in the MIB (i.e. loops, manualforcing etc...).
• Alarm monitoring: acquisition, filtering and correlation of the alarms gathered from slaved µPs. Lo-cal logger and alarm sending to the connected managers: SCT/LCT – NMS5UX. Management of thealarm signalling on the LIM front panel.
• Performances: PM management as per Recc. G.828.
• Download: the main controller is equipped with two flash memory banks containing the running pro-gram (active bank) and the stand–by program (inactive bank). This permits to download a new soft-ware release to the inactive bank without distributing the traffic. Bank switch enables the new release to be used. Download activity is based on FTP protocol which downloads application programs, FPGA configu-ration, configuration files on main controller inactive bank or directly on the peripheral controllers.
Peripheral controllers
The peripheral controllers take place within the ODU and are slaved to main controller with the task of ac-tivating controls and alarm reporting of dedicated functionality.
8.2 IDU LOOPS
To control the IDU correct operation a set of local and remote loops are made available. The commandsare forwarded by the LCT/SCT program. Loop block diagram is shown by Fig.28.
8.2.1 Tributary loop
Tributary local loop
Each input tributary is routed directly to the trib. output upon receiving the command from the LCT. TheTx line transmission is still on.
Tributary remote loop
Each tributary directed towards the Rx output line is routed back to the Tx line. The Rx line is still on.
8.2.2 Baseband unit loop
This kind of loop is only local and is activated at BI/BE level. Tx line is still on.
AL - MN.00142.E - 009 37
8.2.3 IDU loop
This kind of loop permits to check the full IDU digital operation.
Fig.19 - Line interface block diagram – Tx side
edoC
retrevnoc
edoC
r etr evnoc
XU
M2x4/2x22x61/2x8
ees2.8 .gi Fhguorht5.8 .g iF
:IB
ciffart niam –
secivres –C
OE –
CEF –WAF –
emarF
rotarenegz
HM 88.83 0
X
2x n
ZR
N
KC
ZR
N
KC
domed/do
m K
S F –e
m arf 883 –reviecer/rotareneg
niam
mo rf/otrel lortnoc
emarf etagergg
A
zH
M 5.5
zH
M 5.71
38 AL - MN.00142.E - 009
Fig.20 - 2x2 Mbit/s multiplexing/demultiplexing
Fig.21 - 4x2 Mbit/s multiplexing/demultiplexing
MUXproprietary
frameB.I.
DEMUXproprietary
frameB.E.
Ck
Ck
Tx data
Rx data
2x2 Mbit/s
2x2 Mbit/s
Aggregate Ck
MUX 2 –>8G.742
B.I.
DEMUX2 –>8G.742
B.E.
Ck
Ck
Framed data8448 Tx
Framed data8448 Rx
4x2 Mbit/s
4x2 Mbit/s
Aggregate Ck
AL - MN.00142.E - 009 39
Fig.22 - 8x2 Mbit/s multiplexing/demultiplexing
MUX 2 –>8G.742
B.I.
DEMUX8 –> 2G.742
B.E.
Ck 8448 kHz Tx
4x2 Mbit/s
4x2 Mbit/s
Aggregate Ck
MUX 2 –>8G.742
Framed data8448 Tx
4x2 Mbit/s
DEMUX8 –> 2G.742
4x2 Mbit/s
Framed data8448 Rx
Ck
Data
Data
Data
40 AL - MN.00142.E - 009
Fig.23 - 16x2 Mbit/s multiplexing/demultiplexing
MUX2 –>8G.742
B.I.
4x2 Mbit/s
Aggregate Ck
MUX2 –>8G.742
4x2 Mbit/s
MUX2 –>8G.742
4x2 Mbit/s
MUX2 –>8G.742
4x2 Mbit/sMUX
8–>34G.751
Ck 8448 kHz Tx
Framed data8448 kbit/s Tx
Framed data 34368kbit/s
Ck 34368 kHz Tx
DEMUX8 –>2G.742
B.E.
4x2 Mbit/s
Aggregate Ck
DEMUX8 –>2G.742
4x2 Mbit/s
DEMUX8 –>2G.742
4x2 Mbit/s
DEMUX8 –>2G.742
4x2 Mbit/sMUX
34–>8G.751
Ck 8448 kHz
Framed data8448 kbit/s Tx
Framed data 34368kbit/s
Ck 34368 kHz
AL - MN.00142.E - 009 41
Fig.24 - Line interface block diagram (Rx side)
fo edis rotaludom ed
morfecafretni oidar eht
EB
XU
ME
D2x4/2x2/22x61/2x8
2.8 .giF eeS
hguorht5.8 .giF
edoC
ret revnoc
edoC
retrevnoc
2xns/tib
M
42 AL - MN.00142.E - 009
Fig.25 - Radio interface block diagram
elbaC
ecafretni
tne rr ucr evO
.tc etorp
ylppus rewop eto
meR
zH
M 5.5
MA
QD
OM
)trap FI(
zH
M 033
CD
CD
morf ( em arf e t ag erg g a
) ec afre t ni en i l f o IB
y rettabV 84–
V/Itc etorp
petS
nwo d
V 6.3+
V 5–
elbaC
.zilauqe
ME
DM
AQ
)trap FI(
Q&I
zH
M 5.71ecafretni en il
mor f
ecafretni enil ot
AD
y revocer kC –
kcol reirr aC –
.tl if & .zilauq
E – noisi ce
D –.doce d .ffi
D –P/
S –
CR
Cs isylanarengila
&
CEF
.s aem
RE
B –.
M .P –
setamitxe
RE
B –R
EB hgi
H –R
EB
woL –W
E –
enil fo E
B otecafretni
noisrevnoc P/
S –gnidocne .ffid –
g nit alu dom –
rotare ne g lang is
AL - MN.00142.E - 009 43
Fig.26 - Main and peripheral controller connection
Fig.27 - IP/IPoverOSI protocol stack
rellortnoc niaM
s/bk 833
s/tibk 883
NAL
BS
UnI res
U/
mralA
tuO res
U
KSF
medom
KSF
medom
UD
O
CO
E
s/tibk 883rotareneg
reviecer
.cer/neglarehpireP
rellortno cAPPLICATION SOFTWARE
SNMP
TCP/UDP
IPIPoverOSI
IS–ISISO 10589
PPP PPP LLCMAC
LAPDQ921
LCCMAC
USB EOC EthernetLAN EOC Ethernet
LAN
Applic./present.session layers
Transportlayer
Routinglayer
Data linklayer
Physicallayer
44 AL - MN.00142.E - 009
Fig.28 - IDU loopback
XU
M
pool .col .b ir T
NI .b i rT
XU
ME
D
IB E
B
DO
M
TU
O .birT
.mer .b irT
pool
ME
D
UDI
BB
pool
FIrenib
mocU
DIpool
AL - MN.00142.E - 009 45
9 DESCRIPTION OF THE INDOOR UNIT – ETHER-NET INTERFACES
The indoor unit can be provided with Ethernet module. In this way the equipment has both 2 Mbit/s andEthernet ports, and the bit rate assigned to Ethernet traffic is the nominal capacity of the radio minus en-abled tributaries.
Description that follows covers Ethernet signal treatment, 2 Mbit/s signal treatment has been described inprevious chapter.
9.1 TREATMENT OF ETHERNET SIGNALS
In the place of V11 or (V28 + RS232) board it is possible to have Ethernet Module.
In this way the IDU is equipped with the following interfaces:
• 3x electrical interface Ethernet 10/100 BaseT IEEE 802.3
• 16 E1 interfaces in ALC
• 32 E1 interfaces in ALC plus
• total capacity from 4 to 64 Mbit/s (ALC) or from 4 to 105 Mbit/s (ALC plus)
Most important functions are:
• multiplexing of 2 Mbit/s tributaries
• concatenation of 2 Mbit/s streams
• LAPS Link Access Procedure SDH (ITU X.86) for concatenated 2 Mbit/s
• bridge/switch between a local LAN port and the radio LAN port
• MAC switching
• MAC address learning
• MAC address ageing
• Ethernet interface with autonegotiation 10/100, full duplex, half duplex
- Ethernet interface with Flow Control, Back Pressure, MDI/MDX crossover
• network segmentation into bridge
• virtual LAN as per IEEE 802.1q (anyone from 0 to 4095 VID for a maximum of 64 memory location)(see Fig.30)
• layer 2 QoS, priority management as per IEEE 802.1p (see Fig.30)
• layer 3 ToS/DSCP (see Fig.33)
• packet forwarding
A block diagram of IDU with Ethernet module can be found into Fig.29.
In the IDU with Ethernet module there is a "switch" with 3 external ports and 1internal ports. External portsare electrical Ethernet 10/100BaseT interfaces placed on the front panel. Internal port is connected to radioside stream.
Ethernet traffic coming from external ports goes to internal port radio side. The radio side port is connectedto streams group of concatenated 2 Mbit/s.
46 AL - MN.00142.E - 009
The concatenated 2 Mbit/s are assembled in a protocol called LAPS similar to HDLC.
In Tx side Ethernet traffic is packet into a protocol called LAPS similar to HDLC. The resulting stream isdivided into the used number of 2 Mbit/s streams. The 2 Mbit/s streams are then multiplexed, togetherwith 2 Mbit/s arriving from front panel, the resulting stream goes to the modulator, see Fig.29.
In Rx the stream arriving from the demodulator is divided into the 2 Mbit/s streams, then the 2 Mbit/s notused into the front panel 2 Mbit/s are concatenated and sent to Ethernet circuits. Resulting stream, afterLAPS protocol control, is sent to switch internal port.
9.1.1 2 Mbit/s tributaries
Tributary channels at 2 Mbit/s (E1), connected to relevant connectors into front panel, are multiplexed asinto standard IDU, see previous chapter.
From 0 to 16 tributaries can be selected to be used via SCT/LCT program, all the other available 2 Mbit/sare sent to switch internal port.
9.1.2 Electrical Ethernet interface
The electrical Ethernet/Fast Ethernet interfaces are type IEEE 802.3 10/100BaseT with RJ45 connector. Forinput or output signals at RJ45 please refer to User connection chapter. Cable can be UTP (UnshieldedTwisted Pair) or STP (Shielded Twisted Pair) Category 5.
Standard coding:
• Ethernet 10 Mbit/s: Manchester
• Fast Ethernet 100 Mbit/s: MLT–3 ternary
EMC/EMI protection:
• Input and output pins are galvanically isolated through a transformer
• to reduce EMI every pin at RJ45 connector is terminated even if not used
• two signal lines are equipped with low capacity secondary protection to sustain residuals of possibleelectrostatic discharges (ESD).
With LCT/SCT program it is possible to activate autonegotiation (speed/duplex/flow control) on10/100BaseT interface.
9.1.3 Front panel LEDs of Ethernet ports
There are 2 Leds for any Ethernet interface:
• DUPLEX: color green, On = full duplex, OFF = half duplex
• LINK/ACT: color green, ON = link up without activity, OFF = link down, BLINKING = link with activityon Rx and Tx.
9.1.4 Bridge/switch function
A radio link equipped with Ethernet module can operate like a bridge/switch between two or more sepa-rated LANs with the following advantags:
AL - MN.00142.E - 009 47
• to connect two separated LANs at a distance even greater than the maximum limits of 2.5 km (forEthernet)
• to connect two LANs via radio within a complex digital network
• to keep separated the traffic into two LANs towards MAC filtering to get a total traffic greater thantraffic in a single LAN.
The bridge realized into Ethernet module is a transparent bridge (IEEE 802.1 part D) into the same Vlandescribed by VLAN Configuration Table.
The bridge works at data link level, Layer 2 of OSI pile, and leave untouched Layer 3.
The bridge takes care to sendo traffic from a local LAN, to remote LAN. Routing is only on the basic of Level2 addresses, sublevel MAC.
The operation of bridge is the following:
• when a bridge interface receives a MAC frame, the bridge on the basis of destination address, de-cides which LAN to send it
• if destination address is on originating LAN the frame is descarded
• if destination address is a known address (towards address learning procedure) and is present intolocal address table the frame is sent only on destintion LAN (MAC switching)
• otherwise the frame is sent to all ports with the same VLAN ID (flooding).
A bridge is very different from a repeater, which copies slavishly everything that receives from a line onall the others. The bridge, in fact, acquires a frame, analyzes it, reconstruct it and routes it. The bridgecompensates also the different speeds of the interfaces, therefore an input can be at 100 Mbit/s and outputat 10 Mbit/s.
The mechanism is the following:
• from the moment of its activation, the bridge examines all the frames that arrive it from differentLANs, and on these basis it builds its routing tables progressively. In fact, every received frame allows the bridge to know on what LAN the sending station is located(MAC address learning).
• every frame that arrives to the bridge is rebroadcasted:
- if the bridge has the destination address into the routing table, sends the frame only into thecorresponding LAN
- otherwise the frame is sent to all the LANs except the originating (flooding)
- as soon as the bridge increases its knowledge of different machines, the retransmission becomesmore and more selective (and therefore more efficient)
• the routing tables are updated every some minutes (programmable), removing addresses not alivein the last period (so, if a machine is moved, within a few minute it is addressed correctly) (MACaddress ageing).
The whole process of bridging is restricted to the ports which are members of the same Vlan as describedinto Vlan Configuration Table.
9.1.5 Ethernet Full Duplex function
The first realizations of the Ethernet network were on coaxial cable with the 10Base5 standard.
According to this standard Ethernet interfaces (e.g. PC) are connected to the coaxial cable in parallel andare normally in receiving mode. Only one PC, at a certain time, transmits on the cable, the others are re-ceiving, so this is half duplex mode, and only one PC uses the recived message.
Then the coaxial cable was progressively replaced by the pairs cable Unshielded Twisted Pair (UTP) as per10BaseT standard. Normally there are four pairs into UTP Cat5 cable but two pairs are used with 10BaseT,one for Tx one for Rx. Into 10Base5 and 10BaseT standards, network protocols are the same the differencelays into the electrical interface. UTP cable is connected point to point betwen a hub and a Ethernet inter-face. Network structure is a star where the server is connected to a hub and from this a UTP cable is laiddown for each Ethernet interface starts.
48 AL - MN.00142.E - 009
The further step is to replace the hub with a more powerful equipment, e.g. a switch. In this case it ispossible to activate transmission on both pairs at the same time, on one twisted pair for one direction, onthe other pair for opposite direction. Thus we obtain full duplex transmission on UTP.
Activating full duplex transmission it is possible to obtain a theoretical increase of performance of nearly100%. Full duplex mode can be activated into 10/100BaseT interfaces manually or with autonegotiation100BaseFx operates always into full duplex mode.
9.1.6 Link Loss Forwarding
Link Loss Forwarding (LLF) is an alarm status of ethernet interface.
LLF can be enabled or disabled. If LLF is enabled an US radio alarm condition will generate the alarm statusof Ethernet interface blocking any transmission to it. LLF can be enabled for each 3 ports at front panel.With LLF enabled the equipment connected (routers, switches so on) can be notified that radio link is notavailable and can temporarerly reroute the traffic.
9.1.7 MDI/MDIX cross–over
The Ethernet electrical interface can be defined by SCT program as MDI or MDIX to cross–over betweenpairs so that external cross–over cable is not required.
9.1.8 VLAN functionality
LIM Ethernet module works with IEEE 802.1q and 802.1p tag for VLANs and QoS see Fig.30.
The virtual LAN (VLAN) are logical separated subnets so that all the stations, into VLAN, seem to be intothe same physical LAN segment even if they are geographically separated.
The VLAN are used to separate traffic on the same physical LAN too. Station operating on the same physicalLAN but on different VLAN work in separated mode thus they do not share broadcast and multicast mes-sages. This results in a reduction of broadcast generated traffic and above all we get more security thanksto network separation.
Tag position and structure are shown into Fig.30.
Tag is made up with:
• a fixed word of 2 bytes
• 3 bits for priority according 802.1p
• 1 fixed bit
• 12 bits VLAN identifier (VLAN ID) according 802.1q.
Switch crossconnections are based on Vlan Configuration Table where input and output ports or only outputports should be defined for any used VID.
Vlan Configuration Table has 64 position for Vlan ID range from 1 to 4095.
9.1.9 Switch organized by port
For each input port it is possible to define where to route the incoming traffic; one or more of the 3 otherports can be Enabled to exit the incoming traffic. It is possible, also, to route back the incoming traffic into
AL - MN.00142.E - 009 49
the same port. This type of connection are monodirectional. For a dibirectional connection between a ge-neric Lan A and Lan B it is necessary to set the connection from Lan A to Lan B and from Lan B to Lan A.
The IDU with Ethernet module has 3 physical ports and one internal port, radio side. The internal switchcan connect two or more ports together.
Then MAC address bridging rules will be applied to this packet. It is possible to select that a packet followsthe description of Vlan Configuration Table for its Vlan ID.
Another selection is to follow only Vlan Configuration Table.
Packets can exit from a port as Unmodified or all Tagged either all Untagged. Unteggad packets will takedefault tags.
For output operations there are 3 selections:
• Unmodified: tagged packets keep their tag. Untagged packets remain untagged
• Tagged: all the packets will exit tagged, tagged packets keep their tag, untagged packets take De-fault VID of incoming port.
• Untagged: all the packets will exit untagged.
9.1.10 Switch organized by VLAN ID
Vlan Configuration Table
Vlan Configuration Table defines a list of Vlan ID, For any Vlan ID some ports are members of Vlan othersare not members. Ports members of a Vlan are allowed to receive and send packets with that Vlan. Switchdinamically assignes packets to the output port according their VLAN ID.
Packets aren’t sent out to that port unless they belong to one of the Vlan of which the port is a member.
A port can be a member of a Vlan or many Vlan.
A port can be a member from 1 to 64 Vlans but tagged packets are dropped if their input port is not amember of packet’s Vlan.
After the control of packet and port Vlan membership MAC address bridging rules will be applied to thispacket.
Ingress Filtering Check
This is a process to check an incoming packet to compare its Valn ID to input port’s Vlan membership. WithIngress Filtering Check it is possible to permit only to tagged packets to enter the switch. If the port is notmember of the Vlan n. XX all the incoming packets with Vlan ID XX will be dropped.
There are 3 option into Ingress Filtering Check to manage incoming packets:
• Disable: all Tagged and Untagged packets can transit into the switch following setting of swicth or-ganized by port.
• Fallback: Untagged frames follow the rules of switch organized by port, Tagged frames with Vlan IDdescribed into the Vlan Configuration Table follow the rules of the table, Tagged frames with VlanID not described into the Vlan Configuration Table follow the rules of switch organized by port.
• Secure: Untagged frames cannot enter the switch, Tagged frames with Vlan ID described into theVlan Configuration Table follow the rules of the table, Tagged frames with Vlan ID not described intothe Vlan Configuration Table cannot enter the switch.
Operations at the input. At the input port the packet is received and a switching decision must be made.The switch analyse the Vlan ID (if present) and decides whether and where to forward the frame. If thereceived packet is untagged, the switch sends the packet to the port specified into incoming port "Lan perport" settings. If the packet is tagged the switch check the other 3 destination ports to find at least onewith the same Vlan ID and put the packet into output port queue. If the Vlan ID is not listed into VlanConfiguration Table the switch sends the packet to the port specified into incoming port "Lan per port" set-tings.
50 AL - MN.00142.E - 009
Then MAC address bridging rules will be applied to this packet.
Operations at the output. For each output port there are 3 selections for outgoing packets.
• Disable output port
• Enable unchanged: tagged packets keep their tag. Untagged packets remain untagged.
• Enable tagged: all the packets will exit tagged with Vlan ID specified into Vlan Configuration Table,tagged packets keep their tag, untagged packets take Default VID of incoming port.
• Untagged: all the packets will exit untagged.
9.1.11 Layer 2, Priority function, QoS, 802.1p
Some services as voice overIP and videoconference have some time limits to work properly. A solution isto increase the priority of time sensitive packets. In this case random crowding coming from other servicesaffects the delay of prioritized packets a lot less.
Into LIM Ethernet module different priority of incoming packets is managed using Tag defined into IEEE802.1p (see Fig.30).
Every switch output port holds 4 output queues: queue 4 has highest priority, queue 0 has the lowest pri-ority (see Fig.31).
Priority can be organized by incoming port or by incoming priority tag:
• Priority by incoming port. For Untagged packets at each input ports it is decided to send the packetsto one of the 4 queues of output ports defining which is the Default Priority Queue: Queue = 0, 1,2, 3. For Tagged packets it is necessary to Disable Priority so they will go in the same queue ofUntagged packets.
• Priority by incoming priority. For tagged packets for each priority tag (3 bits = for 7 priority levels)it is possible to define where to send the packets, into Queue from 0 to 3. Priority must be enableon 802.1p mode only or IpToS mode only (see next paragraph) or first check 802.1p mode andIpToS mode either first check IpToS mode only (see next paragraph) or first check 802.1p modeand IpToS mode either first check IpToS mode and then 808.1q. For untagged packets the priorityis defined only by incoming port.
Outgoing packet policy at output ports can be WFQ (Wait Fair Queue) with fixed proportional output policy8 packets from Queue 3, 4 from Queue 2, 4 from Queue 1, 1 from Queue 0.
Layer 3, Priority function, QoS, IP–V4 ToS (DSCP)
Only for IP packets it is possible to use incoming Layer 3 ToS (see Fig.32) to prioritize incoming packets.The 8 bits available can be read as 7 bits of ToS or 6 bits of DSCP as shown in Fig.33.
According priority defined into ToS/DSCP the packet is sent into high priority queue low priority queue ofoutput ports.
With SCT/LCT program it is possible to select a different output queue for any ToS/DSCP priority level ateach input port.
AL - MN.00142.E - 009 51
Fig.29 - LIM Ethernet 2 Mbit/s block diagram
Tes aB001/01
TesaB001/01
TesaB001/01
SP
AL
XU
M2x61s/tib
M
XU
M2x61s/tib
M
CONCATENATED 2 Mbit/s
HD
Poidar
PDH RADIO
10/100BaseT 2 Mbit/s
s/tibM 2x61–0
noisrev s/tibM 2x2 3 rof y ln
O
52 AL - MN.00142.E - 009
Fig.30 - Tag control into field
Fig.31 - Output queues
Ethernet Layer 2 Header, non–802.1p
Destination Source Type/Length
Ethernet Layer 2 Header, 802.1p
Destination Source Tag Control Info Type/Length
8100 h
2–Bytes 3–Bits 1–Bit 12–Bits
Tagged frame type interpretation3 bit priorityfield 802.1p Canonical 12–bit 802.1q VLAN Identifier
Ethernet Layer 2 Header, 802.1p
Type = 2 byte (8100)Level 2 priority (802.1p) = 3 bit (value from 0 to 7)Level 2 VLAN (802.1q) = 12 bit (value from 1 to 4095)Canonical form = 1 bit (shows if MAC addresses of current frame are with canonical form):– C = 0 canonical form (MAC with LSB at left) (always into Ethernet 802.3 frames)– C = 1 canonical form (MAC with MSB ay left) (token ring and some FDDI)
Queue 3
Queue 2
Queue 1
Queue 0
Output Port
Input port
AL - MN.00142.E - 009 53
Fig.32 - ToS/DSCP tag position into IP packets
Fig.33 - ToS/DSCP
Version TOS Total Length
Total Length Flags Fragment Offset
IHL
TTL Protocol ID Header Checksum
Source IP Address
Destination IP Address
Options Padding
Data
4 4 8 16
0 1 2 3 4 5 6 7MSB LSB
Not used
Not usedDSCP
ToS
54 AL - MN.00142.E - 009
10 CHARACTERISTICS OF THE OUTDOOR UNIT
10.1 GENERAL
The following ODU characteristics are guaranteed for the temperature range from –33° C to +55° C.
10.2 TECHNICAL SPECIFICATION
- Output power at the antenna side see Tab.11
- Transceiver tuning range
- 7 GHz 42 MHz (154 MHz duplex spacing)56 MHz (161/168/196 MHz duplex spacing)84 MHz (245 MHz duplex spacing)
- 13 GHz 84 MHz
- 15 GHz 119 MHz
- 18 GHz 330 MHz
- 23 GHz 336 MHz
- 25 GHz/28 GHz 448 MHz
- 38 GHz 560 MHz
- RF frequency agility 125 kHz step
- Duplex spacing
- 7 GHz 245/196/168/161/154 MHz
- 8 GHz 311,32 MHz
- 11 GHz 530 MHz
- 13 GHz 266 MHz
- 15 GHz 420/490/728 MHz
- 18 GHz 1010 MHz
- 23 GHz 1008/1232 MHz
- 25 GHz/28 GHz 1008 MHz
- 38 GHz 1260 MHz
- ATPC dynamic range 40 dB
- Transmit power attenuation range 40 dB dynamic, 1 dB software adjustable
- Transmitter shut–down 40 dB
- Antenna side flange
- 7/8 GHz PBR84 or UBR841
- 13 GHz UDR120 or UBR140
AL - MN.00142.E - 009 55
- 15 GHz UDR140 or UBR140
- 18/23/25 GHz PBR220 or UBR220
- 28/38 GHz PBR320 or UBR320
- AGC dynamic range from –20 dBm to threshold corresponding to BER10–3
- Accuracy of Rx level indication (PC reading) ±dB in the range –40 dBm to –75 dBm
- Maximum input level for BER 10–3 ±4 dB in the range –30 dBm to –40 dBm
- Type of connector at the cable interface side –20 dBm
- Signals at the cable interface "N"
- QAM modulated carrier 330 MHz (from IDU to ODU) 140 MHz (from ODU to IDU)
- Telemetry 388 kbit/s
- Telemetry carriers 17.5 MHz (from IDU to ODU) 5.5 MHz (from ODU to IDU)
- Available loops RF loop
Tab.11 - Nominal output power ± 1 dB tolerance
Note
In 1+1 hot stand–by version the output power decreases by the following values:
• –4 dB ±0.5 dB (balanced hybrid)
• –1.7/7 dB ±0.3 dB (unbalanced hybrid)
1 PBR with integrated antenna UBR with separated antenna
GHz Output power 4QAM Output power 16QAM Output power 32QAM
7 +27/30 dBm +22/26 dBm +20/n.a. dBm
8 +27/30 dBm +22/26 dBm +20/n.a. dBm
11 +25/29 dBm +20/25 dBm -
13 +25/29 dBm +20/25 dBm +20/n.a. dBm
15 +25/28 dBm +20/24 dBm +20/n.a. dBm
18 +20/24 dBm +15/20 dBm +15/20 dBm
23 +20/23 dBm +15/19 dBm +15/19 dBm
25 +20/23 dBm +15/19 dBm +15/19 dBm
28 +19/22 dBm +14/18 dBm +14/18 dBm
32 +17/20 dBm +13/16 dBm +13/16 dBm
38 +17/20 dBm +13/16 dBm +13/16 dBm
56 AL - MN.00142.E - 009
11 DESCRIPTION OF THE OUTDOOR UNIT
11.1 GENERAL
The 1+0 ODU (refer to Fig.34) consists of a two aluminium shell mechanical structure, one shell housingall the ODU circuits, the other forming the covering plate.
Two ODU versions are available and are pointed out in the following description if it is necessary. The twoODU versions differ in Tx power and dimensions.
On the ODU are accessible:
• the "N" type connector for cable interfacing IDU and ODU
• the "BNC" connector for connection to a multimeter with the purpose to measure the received fieldstrength
• a ground bolt.
The 1+1 hot stand–by version (refer to Fig.35) consist of two 1+0 ODUs mechanically secured to a struc-ture housing the hybrid for the antenna connection.
11.2 TRANSMIT SECTION
Refer to block diagram shown in Fig.36.
The 330 MHz QAM modulated carrier from the cable interface (see chapter 11.4) is forwarded to a mixerpassing through a cable equalizer for cable loss compensation up to 40 dB at 330 MHz. The mixer and thefollowing bandpass filter give rise to a second IF Tx carrier the frequency of which depends on the go/returnfrequency value. The mixer is of SHP type.
The IF Tx frequency is μP controlled. Same happens to Rx IF and RF local oscillators. This latter is commonto both Tx and Rx sides.
The IF carrier is converted to RF and then amplified making use of a MMIC circuit. The conversion mixer isSSB type with side band selection.
The power at the MMIC output can be manually attenuated, 1 dB step.
The automatic adjustment is performed making use of an ATPC (see paragraph 11.5 for details).
The regulated output power is kept constant against amplifier stage gain variation by a feedback includingthe AGC.
Before reaching the antenna side the RF signal at the output of MMIC passes through the following circuits:
• a decoupler plus detector diode to measure the output power
• a circulator to protect the amplifier stages against possible circuit mismatch.
• a ON/OFF switch for 1+1 operation
• an RF bandpass filter for antenna coupling.
An RF coupler plus a detector and a shift oscillator made up the RF loop which is enabled upon receiving aμP control. The RF loop permits the Tx power to return back to receive side thus controlling the total localradio terminal performance.
AL - MN.00142.E - 009 57
11.3 RECEIVE SECTION
The RF signal from the Rx bandpass filter is sent to a low noise amplifier that improves the receiver sen-sitivity.
The following down–converter translates the RF frequency to approximately 765 MHz.
The conversion mixer is SSB type. The sideband selection is given through a μP control.
A second down converter generates the 140 MHz IF carrier to be sent to the demodulator within the IDU.The level of the IF carrier is kept constant to –5 dBm thank to the IF amplifier stages, AGC controlled,distributed in the IF chain. In addition the AGC gives a measure of the receive RF level.
Between two amplifiers a bandpass filter assures the required selectivity to the receiver. The filter is SAWtype and the bandwidth depends on the transmitted capacity.
11.4 CABLE INTERFACE
The cable interface permits to interface the cable interconnecting IDU to ODU and viceversa.
It receives/transmits the following signals:
• 330 MHz (from IDU to ODU)
• 140 MHz (from ODU to IDU)
• 17.5 MHz (from IDU to ODU)
• 5.5 MHz (from ODU to IDU)
• remote power supply.
The 17.5 MHz and 5.5 MHz FSK modulated carriers, carry the telemetry channel. This latter consists of two388 kbit/s streams one from IDU to ODU with the information to manage the ODU (RF power, RF frequen-cy, capacity, etc...) while the other, from ODU to IDU, sends back to IDU measurements and alarms of theODU. The ODU management is made by a μP.
11.5 ATPC OPERATION
The ATPC regulates the RF output power of the local transmitter depending on the value of the RF level atthe remote terminal. This value has to be preset from the local terminal as threshold high and low. Thedifference between the two thresholds must be equal or higher than 3 dB.
As soon as the received level crosses the preset threshold level low (see Fig.39) due to the increase of thehop attenuation, a microP at the received side of the remote terminal sends back to the local terminal acontrol to increase the transmitted power. The maximum ATPC range is 40 dB.
If the hop attenuation decreases and the threshold high is crossed then the control sent by the microPcauses the output power to decrease.
ATPC range can be reduced from the maximum value to 0 dB, by 1 dB step, consequently to a reductionof the output maximum power through an adjusted attenuation.
58 AL - MN.00142.E - 009
11.6 1+1 Tx SYSTEM
The two ODUs are coupled to the antenna side via a balanced or unbalanced hybrid.
1+1 Tx switching occurs in the 1+1 hot stand–by 1 antenna or 2 antennas versions as shown in Fig.37 andFig.38.
The transmitter switchover is electromechanic type and consists of two ON/OFF switches within the twoODUs that assure at least 40 dB insulation on the stand–by transmitter.
Transmit alarm priority is shown in Tab.12.
Tab.12 - Transmit alarm priority
11.7 POWER SUPPLY
The battery voltage is dropped from the cable interface and then sent to a DC/DC converter to generatethree stabilized output voltages to be distributed to the ODU circuitry:
• +3.5 V
• a voltage comprised between +6.2 V and +8.2 V to power amplifiers operating at different frequen-cy bands
• a –12 V through an inverter circuit.
Each voltage is protected against overcurrent with automatic restart.
Protection against overvoltage occurs as soon as the output voltage raises more than 15% respect to thenominal voltage. The restart is automatic.
Priority Levels Definition
Highest
Priority 1 RIM PSU Alarm
Priority 2 Manual forcing
Priority 3 Cable Short Alarm
Priority 3 Cable Open Alarm
Priority 3 Modulator Failure
Priority 3 ODU Unit Failure Alarm
Priority 3 VCO Failure Alarm
Priority 3 IF Unit Alarm
Priority 3 ODU PSU Alarm
Priority 3 Tx Power Low Alarm
Priority 4Request from remote terminal
(both receivers alarmed)
Lowest Priority 5Revertive Tx
(branch one preferential)
AL - MN.00142.E - 009 59
Fig.34 - 1+0 ODU version
Fig.35 - 1+1 hot stand–by version
”N”
”BNC”
Ground bolt
60 AL - MN.00142.E - 009
Fig.36 - ODU block diagram
elbaC
ecafretn ie lba
C.z ilau qe
CD C
D
petS
pu
T
ANLCI
MM
wb elbairavyticapac(
) gnidneped
CG
A
epyt N
033z
HM
V 84–
x
saem x
RP
041z
HM
041z
HM
.x orppa567z
HM
V 5 .3 +
V 2.8 ot 2. 6+
V 21–
CG
A
x
.tta xTPlortnocBd 04 ot 0
FIOL tinu
DO
M5. 5z
HM
CE
R5.71z
HM
ME
D5.71z
HM
XU
MX
UM
ED
883s/tibk
mralA
ganam
&lort noc
m lA
mmoc
s poo l5 .5z
HM
5 .71z
HM
883s/ tibk
xT FI
anne tnaedis
VNI
CN
B
xR
P.s ae
m
lrtc
OL FR
tinu
xRx T
FR
poollrtc
lrtclr tc
xRxT
AL - MN.00142.E - 009 61
Fig.37 - 1+1 hot stand–by 1 antenna
Fig.38 - 1+1 hot stand–by 2 antennas
Antennaside
SW control
Tx side
Rx side
SW control
Tx side
Rx side
Firstantenna
SW control
Tx side
Rx side
SW control
Tx side
Rx side
Secondantenna
62 AL - MN.00142.E - 009
Fig.39 - ATPC operation
Thresh High
Thresh Low
Hop attenuation (dB)
20 dBATPC range
PTxmax.
PTxmin.
RemotePRxdBm
LocalPTxdBm
Hop attenuation (dB)
Tx
Rx
Rx
Tx
PTxactuation
Local Remote
PRx recording
Transmission
of PTx control
µP µPlevel
PTx control
AL - MN.00142.E - 009 63
12 24/48 VOLT DC/DC CONVERTER D52089
12.1 GENERAL
The 24/48V DC/DC converter D52089 is a unit which converts the voltage of 24 Vdc in –48 Vdc.
This unit is housed in a subrack 1 RU unit G52004 with two D52089 units (1+1 version). For 1+0 versionthe subrack is G52003 with one D52089 unit and the remaining half front panel has a cover.
These subracks have a free air gap for cooling purpose.
The DC/DC converter unit D52089 is shown in Fig.40.
Fig.40 - DC/DC converter front coverplate
12.2 ENVIRONMENTAL CONDITIONS
- Operational range -10° ÷ 50° C
- Storage range -40° ÷ 80° C
- Operational humidity 90% max in the range -5° ÷ 30° C
12.3 ELECTRICAL CHARACTERISTICS
- Vinput 24 Vdc (20.4 ÷ 28.8 Vdc floating)
- Voutput 52 Vdc
- Max current in input 4.5 A
- Max 24 Vdc consumption 90 W
- Max 48 Vdc load 75 W
- Secondary voltage ripple ≤ 200 mVpp
- Surge current (Inrush current) ETS 300 132-2
- Conducted immunity ETS 300 132-2
+ – – +
6,3A250V
M ON 24VdcIN
48VdcOUT2A
ALARM
Green LED CM2 connector
Fuse 6.3 A 24 Vdc input male 3W3 connector
48 Vdc output female 3W3 connector
64 AL - MN.00142.E - 009
- Conducted emission ETS 300 132-2
- Short duration voltage transient ETS 300 132-2 (ETR 283)
- Abnormal service voltage ETS 300 132-2
- Voltage changes due to the regulation of power supply ETS 300 132-2
- Electromagnetic compatibility EN 300 086
- Safety EN 60950-1
- Protections against - input polarity inversion (fuse) - surge input current (fuse) - continuous short circuit at output with automatic recovery
- Visual indication ON = green led active on input primary voltagepresent
- Alarm (CM2 connector) with relay contact on 9 pin male SUB–D connector Alarm off: 8–9 pin open, 7–9 pin closed Alarm on when Vout decreases ≥ 15%: 8–9 pinclosed, 7–9 pin open
- Fuse 6.3 A medium time 250 Volt
Fig.41 shows connection from IDU 1+0 AL compact version to 24/48 V converter with cable F03489.
Fig.42 shows connections from IDU 1+1 AL compact version to 24/48 V converter with cables F03489 andF03278.
Warning: connect only 24 Vdc to primary input 24 Vdc IN.
Warning: power supply from –48 Vdc must be connected directly to ALC IDU.
AL - MN.00142.E - 009 65
Fig.41 - 24/48 V DC/DC converter connections to IDU 1+0
V052MA 3, 6
NO
NIcd
V 42A2T
UO
c dV8 4
MR
ALA
+
––
+
98430F
A 3.6 esuFNI cdV 42
V84
+
–
4–3–2–1 .b irT
8–7–6–5 .birT
SP
TCL
TU
O/NI
RESU
3Q
R
TS
ET
LA
3002 5G : gninra
WNI cdV 42 tupni yra
mirp ot cdV 42 ylno tcennoc
66 AL - MN.00142.E - 009
Fig.42 - 24/48 V DC/DC converter connections to IDU 1+1
V05 2M
A3 ,6 N
ONI
cdV4 2
A 2T
UO
cdV 84
MR
ALA
MV052
A3,6 N
ONI
cdV42
A2T
UO
cdV8 4
MR
ALA
+
––
+
+
––
+
21
XR
XT
LAT
SET R
TU
O/N I
RESU
3Q
TCL
2S
P
1S
P
61 –51– 41–3 1 .b irT8–7– 6–5 .bir T
1–01–9 .birT21–1
4 –3–2– 1 .b irT
21
21
2V84
+
––
+
1V84
98430F87230F
NI cdV 42
NI cdV 42
esuFA 3.6
A 3.6 esuF
:g nin raW
NI c dV 42 tu pni y rami rp ot c dV 42 y lno t ce nnoc
AL - MN.00142.E - 009 67
Section 3.INSTALLATION
13 INSTALLATION AND PROCEDURES FOR ENSUR-ING ELECTROMAGNETIC COMPATIBILITY
13.1 GENERAL
The equipment consists of IDU and ODU(s) units and is mechanically made up of a wired 19" subrack (IDU)and a weather proof metallic container (ODU). The two units are shipped together in an appropriate card-board box.
After unpacking, mechanical installation takes place followed by electrical connections as described in thefollowing paragraphs.
Different versions of IDUs and ODUs are pointed out in the following procedures if different steps are re-quested during installation.
13.2 MECHANICAL INSTALLATION
13.2.1 IDU installation
The front side of the IDU mechanical structure is provided with holes at the sides. This allows to fasten thesubrack to a 19" rack by means of four M6 screws.
If two or more IDUs are to be mounted, leave at least 1/2 rack unit space (22 mm) between two IDUs toavoid overheating problems.
68 AL - MN.00142.E - 009
13.3 ELECTRICAL WIRING
The electrical wiring must be done using appropriate cables thus assuring the equipment complies withelectromagnetic compatibility standards.
The cable terminates to flying connectors which have to be connected to the corresponding connectors onthe equipment front.
Position and pin–out of the equipment connectors are available in this section.
Tab.13 shows the characteristics of the cables to be used and the flying connector types.
Tab.13 - Characteristics of the cables
Interconnecting points Type of connector terminat-
ing the cable
Type of cable/conductor a
a. For power cable lenght longer than 20 m. a section of 4 mm2 is required.
BatteryPolarised SUB–D 3W3 female
connector Section of each wire ≥ 2.5 mm2
Tributary signals25 pin SUB–D male connector
120 Ohm balanced four symmet-ric pairs with shield
Coaxial connector 1.0/2.3 75 Ohm unbalanced with shield
User input/alarm output 9 pin SUB–D female connector
with shielded holder
9 conductor cable with double brass sheath type interconductor
DB28.25 or equivalent
LCT USB connector USB connector
GND Faston male type Section area ≥ 6 mm2
AL - MN.00142.E - 009 69
13.4 GROUNDING CONNECTION
Fig.43 and annexed legend show how to perform the grounding connections.
Legend
1. IDU grounding point, fast–on type. The cross section area of the cable used must be ≥ 4 mm2. Thefast–on is available on both sides of the IDU.
2. ODU grounding bolt. The cross section area of the cable used must be ≥ 16 mm2.
3. IDU–ODU interconnection cable type Celflex CUH 1/4" terminated with N–type male connectors atboth sides.
4. Grounding kit type Cabel Metal or similar to connect the shield of interconnection cable.
5. Matching cable (tail) terminated with SMA male and N female connectors.
6. Battery grounding point of IDU to be connected to earth by means of a cable with a section area2.5 mm2. Length ≤ 10 m.
7. Grounding cords connected to a real earth inside the station. The cross section area of the cablemust be = 16 mm2.
Fig.43 - Grounding connections
IDUunit
ODUunit
2
6(+) (–)
4
Localground
rackground
Indoor
Stationground
7
1 5
3 4 3
70 AL - MN.00142.E - 009
14 ALC USER CONNECTIONS
14.1 CONNECTOR USE FOR 1+0/1+1 ALC VERSION
User connections are performed through connectors on the IDU front panel modules (see Fig.44). The con-nectors are the following:
• Trib IN/OUT: 75 or 120 25–pin SUB–D male connector. For SUB–D connector details Fig.44.
• LCT: USB connector B type "Receptacle". For connector detail see USB standard.
• USER IN/OUT: SUB–D male connector. Connector details refer to Tab.19.
• Q3: RJ45 connector. Connector details refer to Tab.15.
• 50 Ohm connector for interconnection to ODU2.
• 48V: 3 pin SUB–D 3W3 connector for interconnection to battery.
• V11: optional service interface. Connector details in Tab.16.
• V.28: optional service interface. Connector details in Tab.17.
• RS232 PPP: optional management interface. Connector details inTab.18.
Fig.44 - IDU ALC 1+1 (2x2/4x2/8x2/16x2 Mbit/s)
2 SMA kind: max torque 0.5 Nm
21
RXTX
ALTEST
R
USER IN/OUTQ3 LCT
PS2
PS1
Trib. 13–14–15–16Trib. 5–6–7–8
Trib. 9–10–11–12Trib. 1–2–3–4
2121
48V2
+ ––
+
48V1
AL - MN.00142.E - 009 71
14.2 STANDARD VERSION CONNECTORS
Tab.14 - Tributary connector pin–out (male 25 pin SUB–D)
Pin 120 Ohm impedance Pin 75 Ohm impedancea
a. The 75 Ohm impedance tributary connector pin–out is referred to the flying connectors to be connectedto the equipment connectors.
1 Tributary 1/5/9/13 input (cold wire) Ground
2 Tributary 1/5/9/13 input (hot wire) 2 Tributary 1/5/9/13 input
14 Tributary 1/5/9/13 input (ground) 14 Ground
15 Tributary 1/5/9/13 output (cold wire) 15 Ground
16 Tributary 1/5/9/13 output (hot wire) 16 Tributary 1/5/9/13 output
3 Tributary 1/5/9/13 output (ground) 3 Ground
4 Tributary 2/6/10/14 input (cold wire) 4 Ground
5 Tributary 2/6/10/14 input (hot wire) 5 Tributary 2/6/10/14 input
17 Tributary 2/6/10/14 input (ground) 17 Ground
18 Tributary 2/6/10/14 output (cold wire) 18 Ground
19 Tributary 2/6/10/14 output (hot wire) 19 Tributary 2/6/10/14 output
6 Tributary 2/6/10/14 output (ground) 6 Ground
7 Tributary 3/7/11/15 input (cold wire) 7 Ground
8 Tributary 3/7/11/15 input (hot wire) 8 Tributary 3/7/11/15 input
20 Tributary 3/7/11/15 input (ground) 20 Ground
21 Tributary 3/7/11/15 output (cold wire) 21 Ground
22 Tributary 3/7/11/15 output (hot wire) 22 Tributary 3/7/11/15 output
9 Tributary 3/7/11/15 output (ground) 9 Ground
10 Tributary 4/8/12/16 input (cold wire) 10 Ground
11 Tributary 4/8/12/16 input (hot wire) 11 Tributary 4/8/12/16 input
23 Tributary 4/8/12/16 input (ground) 23 Ground
24 Tributary 4/8/12/16 output (cold wire) 24 Ground
25 Tributary 4/8/12/16 output (hot wire) 25 Tributary 4/8/12/16 output
12 Tributary 4/8/12/16 output (ground) 12 Ground
13 Ground 13 Ground
72 AL - MN.00142.E - 009
Tab.15 - 100BaseT connector pin–out for 10/100BaseT Ethernet connection
Tab.16 - Connector pin–out for 64 kbit/s channel – V.11 interface
Tab.17 - Connector pin–out – V.28 interface
Pin Description
1 Tx+
2 Tx-
3 Rx+
4 --
5 --
6 Rx-
7 --
8 --
Pin Description
1 D-V11-Tx
2 D+V11-Tx
3 C-V11-Tx
4 C+V11-Tx
5 D-V11-Rx
6 D+V11-Rx
7 C-V11-Rx
8 C+V11-Rx
Pin Description
1 RTS
2 TD
3 DTR
4 DSR
5 GND
6 RD
7 CTS
8 DCD
AL - MN.00142.E - 009 73
Tab.18 - Connector pin–out – RS232 PPP interface
Tab.19 - User in/out connector pin–out
Pin Description
1 DCD
2 RD
3 TD
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
9 NC
Pin Description
1 relay contact
2 NA/NC relay contact
3 User input 01
4 User input 02
5 GND
6 NC
7 User input 03
8 User input 04
9 NC
74 AL - MN.00142.E - 009
15 ALC PLUS USER CONNECTIONS
15.1 CONNECTOR USE FOR 1+0/1+1 ALC PLUS VERSION
User connections are performed through connectors on the IDU front panel modules (see Fig.45 andFig.46). The connectors are the following:
• Trib IN/OUT: 75 and 120 50-pin female connector: for SCSI connector details Tab.20, Tab.21
• LCT: USB connector B type receptable. For connector details see USB standard.
• USER IN/OUT: SUB-D male connector. Connector details refer to Tab.27
• Q3/1 and Q3/2: RJ45 connector. Connector details refer to Tab.22
• 50 Ohm SMA connector for interconnection to ODU
• 48V: SUB-D 3 pin connector for interconnection to battery.
• V11: service interface. Connector details in Tab.26
• RS232 management interface. Connector details in Tab.23
Fig.45 - ALC plus 32E1 (1+1)
Fig.46 - ALC plus 32E1 + Ethernet (1+1)
+ -
-+
Q3/1R
IDU ODU
TESTREM
SIDE
2Mb/sCH2CH1RS232 USER IN/OUTLCT
A WAYQ3/2
FAIL
Trib: 1-8 Trib: 9-16 Trib: 17-24 Trib: 25-32
FAIL
Trib: 1-8 Trib: 9-16 Trib: 17-24 Trib: 25-32
Q3/2WAYA
LCT USER IN/OUTRS232 CH1 CH2 2Mb/s
SIDE
REM TEST
ODUIDUR
Q3/1
+ -
-+
FAIL
Trib: 33-40 Trib: 41-48 Trib: 49-53
AL - MN.00142.E - 009 75
Tab.20 - Tributary IN/OUT - 75 Ohm
Note: Join pin 44 with ground A pins, join pin 32 with ground B pins.
Fig.47 - Pin-out Tributary IN/OUT 50 SCSI
Pin 75 Ohm
48 Ground A
23 Tributary 1/9/17/25/33/41/49 input
50 Ground A
25 Tributary 1/9/17/25/33/41/49 output
47 Ground A
22 Tributary 2/10/18/26/34/42/50 input
45 Ground A
20 Tributary 2/10/18/26/34/42/50 output
42 Ground A
17 Tributary 3/11/19/27/35/43/51 input
43 Ground A
18 TributaryTributary 3/11/19/27/35/43/51 output
40 Ground A
15 Tributary 4/12/20/28/36/44/52 input
39 Ground A
14 Tributary 4/12/20/28/36/44/52 output
36 Ground B
11 Tributary 5/13/21/29/37/45/53 input
37 Ground B
12 Tributary 5/13/21/29/37/45/53 output
34 Ground B
9 Tributary 6/14/22/30/38/46 input
33 Ground B
8 Tributary 6/14/22/30/38/46 output
29 Ground B
4 Tributary 7/15/23/31/39/47 input
31 Ground B
6 Tributary 7/15/23/31/39/47 output
28 Ground B
3 Tributary 8/16/24/32/40/48 input
26 Ground B
1 Tributary 8/16/24/32/40/48 output
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
125
2650
76 AL - MN.00142.E - 009
Tab.21 - Tributary IN/OUT - 120 Ohm
Pin 120 Ohm
49 Tributary 1/9/17/25/33/41/49 input
23 Tributary 1/9/17/25/33/41/49 input
44 Ground A
24 Tributary 1/9/17/25/33/41/49 output
25 Tributary 1/9/17/25/33/41/49 output
44 Ground A
21 Tributary 2/10/18/26/34/42/50 input
22 Tributary 2/10/18/26/34/42/50 input
44 Ground A
46 Tributary 2/10/18/26/34/42/50 output
20 Tributary 2/10/18/26/34/42/50 output
44 Ground A
16 Tributary 3/11/19/27/35/43/51 input
17 Tributary 3/11/19/27/35/43/51 input
44 Ground A
19 Tributary 3/11/19/27/35/43/51 output
18 Tributary 3/11/19/27/35/43/51 output
44 Ground A
41 Tributary 4/12/20/28/36/44/52 input
15 Tributary 4/12/20/28/36/44/52 input
44 Ground A
13 Tributary 4/12/20/28/36/44/52 output
14 Tributary 4/12/20/28/36/44/52 output
44 Ground A
10 Tributary 5/13/21/29/37/45/53 input
11 Tributary 5/13/21/29/37/45/53 input
32 Ground B
38 Tributary 5/13/21/29/37/45/53 output
12 Tributary 5/13/21/29/37/45/53 output
32 Ground B
35 Tributary 6/14/22/30/38/46 input
9 Tributary 6/14/22/30/38/46 input
32 Ground B
7 Tributary 6/14/22/30/38/46 output
8 Tributary 6/14/22/30/38/46 output
32 Ground B
AL - MN.00142.E - 009 77
Tab.22 - Q3/1 and Q3/2 100BaseT connector pin-out for 10/100BaseT Ethernet connection
Tab.23 - Connector pin-out RS232 PPP interface
5 Tributary 7/15/23/31/39/47 input
4 Tributary 7/15/23/31/39/47 input
32 Ground B
30 Tributary 7/15/23/31/39/47 output
6 Tributary 7/15/23/31/39/47 output
32 Ground B
27 Tributary 8/16/24/32/40/48 input
3 Tributary 8/16/24/32/40/48 input
32 Ground B
2 Tributary 8/16/24/32/40/48 output
1 Tributary 8/16/24/32/40/48 output
32 Ground B
Pin Description
1 Tx+
2 Tx-
3 Rx+
4 --
5 --
6 Rx-
7 --
8 --
Pin Description
1 DCD (IN)
2 RD (IN)
3 TD (OUT)
4 DTR (OUT)
5 GND
6 Not connected
7 RTS (OUT)
8 CTS (IN)
9 Not connected
78 AL - MN.00142.E - 009
Tab.24 - CH1 connector pin-out for 9600 bit/s synchronous V.24 interface
Tab.25 - CH1 connector pin-out for 9600 bit/s asynchronous V.24 interface
Tab.26 - CH2 connector pin-out for 64 kbit/s channel - V.11 interface
Pin Description
1 CKTx
2 TD
3 DTR
4 DSR
5 GND
6 RD9600
7 CKRx
8 DCD
Pin Description
1 --
2 TxD
3 DTR
4 DSR
5 GND
6 RxD
7 --
8 DCD
Pin Description
1 D-V11-Tx
2 D+V11-Tx
3 C-V11-Tx
4 C+V11-Tx
5 D-V11-Tx
6 D+V11-Tx
7 C-V11-Tx
8 C+V11-Tx
AL - MN.00142.E - 009 79
Tab.27 - User IN/OUT connector pin-out
Pin Description
1 C relay contact- branch 1
2 NA/NC relay contact - branch 1
3 C relay contact - branch 2
4 NA/NC relay contact - branch 2
5 User input 01
6 User input 02
7 User input 03
8 User input 04
9 Ground
80 AL - MN.00142.E - 009
16 INSTALLATION ONTO THE POLE OF THE ODU WITH SEPARATED ANTENNA
16.1 INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions:
• 1+0 standard version
- antisliding strip (see Fig.48)
- supporting plate plus 60–114 mm pole fixing bracket and relevant nuts and bolts (see Fig.49)
- adapting tools and relevant bolts and nuts for 219 mm pole (see Fig.50)
- antenna side flange, variable as function of RF frequency (see Fig.51)
- support with ODU fast locking mechanism (see Fig.49)
- flexible waveguide trunk for connection to antenna (optional) (see Fig.49)
- kit for ground connection making part of ODU
• 1+0 Band–it version
- band–it strip (see Fig.53)
- antenna side flange, variable as function of RF frequency (see Fig.51)
- support with ODU fast locking mechanism (see Fig.49)
- flexible waveguide trunk for connection to antenna (optional) (see Fig.49)
- kit for ground connection making part of ODU
• 1+1 version
- antisliding strip (see Fig.48)
- supporting plate plus pole fixing bracket and relevant nuts and bolts (see Fig.49)
- adapting tools and relevant bolts and nuts for 219 mm pole (see Fig.50)
- hybrid with ODU fast locking mechanism (see Fig.52)
- flexible waveguide trunk for connection to antenna (optional (see Fig.49)
- kit for ground connection making part of the two ODUs.
16.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)
• N. 2 13mm torque wrench or spanner
• N. 1 15 mm torque wrench or spanner
• N. 1 17 mm torque wrench or spanner
• N. 1 3 mm Allen wrench
• N.1 2.5 mm Allen wrench
AL - MN.00142.E - 009 81
• N. 1 7 mm torque wrench
• Fastening tool UIT19 (Band–it mounting kit only)
16.3 INSTALLATION PROCEDURE
Installation procedure proceeds according to the following steps:
• 1+0 standard: installation onto the pole of the supporting plate3
• 1+0 Band–it: installation onto the pole of the supporting plate
• 1+1: installation onto the pole of the supporting plate 3
• Installation of the ODU (common to both 1+0 and 1+1 version)
• ODU grounding
1+0 standard – Installation onto the pole of the supporting plate
Fig.48 - Mount antislide strip around the pole. The position of the plastic blocks depends on the position of thesupporting plate (see next step)
Fig.49 - Adhere the supporting plate to the antisliding strip plastic blocks and then secure it to the pole throughthe fixing bracket for 60–114 mm pole (see Fig.49). Bolts and nuts are available on the supporting plate. Tight-ening torque must be 32 Nm.
Warning: As shown in Fig.50 an adapting kit must be used for the 219 mm pole. It consists of an additional plateto enlarge the standard supporting plate dimension and relevant U–bolt for 219 mm pole fixing.
Fig.51 - Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensionsof which depend on the waveguide type. Tighten progressively and alternatively the four screws with the follow-ing torque:
Tab.28 - Tightening torque
Fig.51 – Fix the antenna side flange to the support with ODU fast locking mechanism. The flange can be mountedhorizontally (as shown in Fig.51) or vertically as function of convenience.
Fig.52 – Fix the support with ODU fast locking mechanism to the supporting plate making use of available boltsand nuts. Fig.52 shows three possible positions.
Tightening torque must be 18 Nm.
1+0 Band–it
In case of 1+0 ODU installation, a band–it pole mounting kit can be used: through slots (see Fig.53) on thesupporting plate two metallic bands secure the plate on the pole by means of clips (use Band–it fastening tool).
Band characteristics are:
• thickness 0.76 mm
• width 19 mm
• steel stainless strip AISI 201/304 (3/4")
3 In case of 219 mm pole, an adapting kit is supplied for the purpose.
Frequencies Screw Tool Torque
from 18 to 38 GHz Allen screw M3 Allen key 2.5 mm 1 Nm
up to 15 GHz Allen screw M4 Allen key 3 mm 2 Nm
82 AL - MN.00142.E - 009
• clips stainless steel AISI 201/304 (3/4")
Fig.51 – Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions ofwhich depend on the waveguide type. Tighten progressively and alternatively the four screws with the followingtorque (see Tab.28).
1+1 – Installation onto the pole of the supporting plate
Fig.48 – Mount antislide strip around the pole. The position of the plastic blocks depends on the position of the sup-porting plate (see next step)
Fig.49 – Position the supporting plate to the antisliding strip plastic blocks and then secure it to the pole through thefixing bracket for 60–114 mm pole (see Fig.49). Bolts and nuts are available on the supporting plate kit. Tighteningtorque must be 32 Nm.
Fig.54 – Secure the hybrid with ODU fast locking mechanism to the supporting plate using bolt and nuts available onthe support plate. Tightening torque must be 18 Nm.
Remove the plastic cover from the hybrid flange sides.
Warning: Do not remove the foil from the hybrid flange sides.
Fig.54 – Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimensions ofwhich depend on the waveguide type. Tighten progressively and alternatively the four screws with the followingtorque:
Tab.29 - Tightening torque
Warning: It is advisable to shape the waveguide flexible trunk, connecting ODU flange with antenna flange as shownin Fig.57. This avoids possible condensate to be channelled towards the ODU flange.
Installation of the ODU
1. Remove the plastic cover from the ODU flange side. Apply silicon grease e.g. type RHODOSIL PATE 4 to theO–ring of Fig.56. Warning: Do not remove the foil from the flange.
2. Bring the ODU with the two hands and position the ODU handle at the bottom side.
3. Position the ODU body close to the support with ODU fast locking mechanism and align ODU side flange (seeFig.56) to antenna side flange (see Fig.51 – 1+0 version) or hybrid side flange (see Fig.54 – 1+1 version).
Note: For 1+0 version the ODU can assume positions of Fig.55 depending on the polarisation.
4. With respect to the flange alignment, turn the ODU body approx. 30° anti–clockwise and then insert the ODUbody into the support and search for alignment between reference tooth on the support (see Fig.51 – 1+0version or Fig.54 – 1+1 version) and ODU body reference tooth (see detail Fig.56)
5. When alignment is achieved, turn the ODU body clockwise until "clack" is heard and the ODU rotation stops.
6. Secure ODU body on the support by tightening bolts (1) (see Fig.51 – 1+0 version or Fig.54 – 1+1 version).Tightening torque must be 6 Nm.
Final assembly of 1+1 version is shown in Fig.57.
16.4 GROUNDING
The ODU must be connected to ground making reference to details of Fig.58.
Frequencies Screw Tool Torque
from 18 to 38 GHz Allen screw M3 Allen key 2.5 mm 1 Nm
fino a 15 GHz Allen screw M4 Allen key 3 mm 2 Nm
AL - MN.00142.E - 009 83
Fig.48 - Antisliding strip
Antisliding strip Plastic blocks
7 mm spanner orPhillips screwdriver
84 AL - MN.00142.E - 009
Fig.49 - 60–114 mm pole supporting plate fixing
Supporting plate
Use 15 mm wrench(32Nm torque)
Use 17 mm wrench(32Nm torque)
AL - MN.00142.E - 009 85
Fig.50 - Adapting kit for 219 mm pole
86 AL - MN.00142.E - 009
Fig.51 - Mounting possible position
Flexible waveguide trunk orrigid angular waveguide
Antenna side flange
Support with ODU fastlocking mechanism
Reference tooth
Position of antennaside flange
Reference tooth
11
13 mm wrench 6 Nm torque
3 mm Allen key
AL - MN.00142.E - 009 87
Fig.52 - Possible position of the fast locking mechanism
13 mm wrench(18 Nm torque)
88 AL - MN.00142.E - 009
Fig.53 - Band–it pole mounting
AL - MN.00142.E - 009 89
Fig.54 - Supporting plate
Use 13 mm wrench(18 Nm torque)
Reference toothReference tooth
Hybrid with ODU fastlocking mechanism
1
1
RT1 RT2
90 AL - MN.00142.E - 009
Fig.55 - Position of the ODU body depending on the polarisation for 1+0. For 1+1 the polarisa-tion is always vertical: handle at the left side.
Vertical Horizontal
AL - MN.00142.E - 009 91
Fig.56 - ODU body reference tooth
”N
”BNC”
Ground bolt
ODU side flange
Reference tooth
O–ring
92 AL - MN.00142.E - 009
Fig.57 - Final ODU assembly of 1+1 version
AL - MN.00142.E - 009 93
1. Bolt
2. Spring washer
3. Flat washer
4. Earth cable collar
5. Flat washer
Fig.58 - ODU grounding
12
4
3
5
13 mm torque wrench(6 Nm torque)
94 AL - MN.00142.E - 009
17 INSTALLATION ONTO THE WALL OF THE ODU WITH SEPARATED ANTENNA
17.1 INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions:
• 1+0 version
- wall supporting plate with additional contact surface extension plates (see Fig.59)
- antenna side flange, variable as function of RF frequency (see Fig.60 )
- support with ODU fast locking mechanism (see Fig.60)
- flexible waveguide trunk for connection to antenna (optional) (see Fig.60)
- kit for ground connection making part of ODU
• 1+1 version
- supporting plate with additional contact surface extension tools (see Fig.59)
- hybrid with ODU fast locking mechanism (see Fig.62)
- flexible waveguide trunk for connection to antenna (optional (see Fig.60)
- kit for ground connection making part of the two ODUs.
17.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)
• N. 2 13mm torque wrench
• N. 1 15 mm torque wrench
• N. 1 17 mm torque wrench
• N. 1 3 mm Allen wrench
• N. 1 2.5 mm Allen wrench
AL - MN.00142.E - 009 95
17.3 INSTALLATION PROCEDURE
Installation procedure proceeds according to the following steps:
• Version 1+0: installation onto the wall of the supporting plate
• Version 1+1: installation onto the wall of the supporting plate
• Installation of the ODU (common to both 1+0 and 1+1 version)
• ODU grounding
1+0 version – Installation onto the wall of the supporting plate
Fig.59 – Fix on the supporting plate the two supplied extension plates to increase the wall contact surface.
Fig.59 – Secure the supporting plate on the wall using the more suitable screws.
Fig.60 – Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimen-sions of which depend on the waveguide type. Tighten progressively and alternatively the four screws withthe following torque:
Tab.30 - Tightening torque
Fig.60 – Fix the antenna side flange to the support with ODU fast locking mechanism. The flange can bemounted horizontally (as shown in Fig.60) or vertically as function of convenience.
Fig.61 – Fix the support with ODU fast locking mechanism to the supporting plate making use of availablebolts and nuts. Fig.61 shows three possible positions. Tightening torque must be 18 Nm.
1+1 version – Installation onto the wall of the supporting plate
Fig.59 – Fix on the supporting plate the two supplied extension plates to increase the wall contact surface.
Fig.59 – Secure the supporting plate on the wall using the more suitable screws.
Fig.62 – Secure the hybrid with ODU fast locking mechanism to the supporting plate using bolt and nutsavailable on the support plate. Tightening torque must be 18 Nm. Remove the plastic cover from the hybrid flange sides.
Warning: Do not remove the foil from the hybrid flange sides.
Fig.62 – Fix the flexible waveguide to the antenna side flange. Four fixing screws are available the dimen-sions of which depend on the waveguide type. Tighten progressively and alternatively the four screws withthe following torque:
Tab.31 - Tightening torque
Warning: It is advisable to shape the waveguide flexible trunk, connecting ODU flange with antenna flangeas shown in Fig.65. This avoids possible condensate to be channelled towards the ODU flange.
Frequencies Screw Tool Torque
from 18 to 38 GHz Allen screw M3 Allen key 2.5 mm 1 Nm
up to 15 GHz Allen screw M4 Allen key 3 mm 2 Nm
Frequencies Screw Tool Torque
from 18 to 38 GHz Allen screw M3 Allen key 2.5 mm 1 Nm
up to 15 GHz Allen screw M4 Allen key 3 mm 2 Nm
96 AL - MN.00142.E - 009
Installation of the ODU
1. Remove the plastic cover from the ODU flange side. Apply silicon grease e.g. type RHODOSIL PATE 4 to theO–ring of Fig.64. Warning: Do not remove the foil from the flange.
2. Bring the ODU with the two hands and position the ODU handle at the bottom side.
3. Position the ODU body close to the support with ODU fast locking mechanism and align ODU side flange (seeFig.64) to antenna side flange ( see Fig.60 – 1+0 version) or hybrid side flange (see Fig.62 – 1+1 version).
Note: For 1+0 version the ODU can assume positions of Fig.63 depending on the polarisation.
4. With respect to the flange alignment, turn the ODU body approx. 30° anti–clockwise and then insert the ODUbody into the support and search for alignment between reference tooth on the support (see Fig.60 – 1+0version or Fig.62 – 1+1 version) and ODU body reference tooth (see detail Fig.64)
5. When alignment is achieved, turn the ODU body clockwise until "clack" is heard and the ODU rotation stops.
6. Secure ODU body on the support by tightening bolts (1) (see Fig. Fig.60 – 1+0 version or Fig.62 – 1+1 ver-sion). Tightening torque must be 6 Nm.
Final assembly of 1+1 version is shown in Fig.65.
17.4 GROUNDING
The ODU must be connected to ground making reference to details of Fig.66.
AL - MN.00142.E - 009 97
Fig.59 - Wall supporting plate
Extension plate
Supporting plate
M8 bolt and nut
13 mm wrench
98 AL - MN.00142.E - 009
Fig.60 - Support with ODU fast locking mechanism
Flexible waveguide trunk
Antenna side flange
Support with ODU fastlocking mechanism
Reference tooth
Position of antennaside flange
Reference tooth
11
13 mm wrench 6 Nm torque
AL - MN.00142.E - 009 99
Fig.61 - Mounting possible positions
100 AL - MN.00142.E - 009
Fig.62 - Hybride with ODU fast locking
Use 13 mm wrench(18 Nm torque)
Reference toothReference tooth
Hybrid with ODU fastlocking mechanism
1
1
RT1 RT2
AL - MN.00142.E - 009 101
Fig.63 - Position of the ODU body depending on the polarisation for 1+0. For 1+1 the polarisa-tion is always vertical: handle at the left side.
Vertical Horizontal
102 AL - MN.00142.E - 009
Fig.64 - ODU body reference tooth
”N
”BNC”
Ground bolt
ODU side flange
Reference tooth
O–ring
AL - MN.00142.E - 009 103
Fig.65 - Final ODU assembly of 1+1 version
104 AL - MN.00142.E - 009
1. Bolt
2. Spring washer
3. Flat washer
4. Earth cable collar
5. Flat washer
Fig.66 - ODU grounding
12
4
3
5
AL - MN.00142.E - 009 105
18 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA (KIT V52191, V52192)
18.1 FOREWORD
The installation onto the pole of the ODU with integrated antenna concerns both 1+0 and 1+1 versions.
18.2 INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions:
1+0 version
• 60 to 114 mm pole mounting kit consisting of:
- centering ring and relevant screws (see Fig.67)
- antislide strip (see Fig.68)
- pole support system and pole fixing brackets (see Fig.69)
- ODU with O–ring and devices for ground connection
1+1 version
• pole mounting kit from 60 to 114 mm for 1+1 consisting of:
- centering ring and relevant screws (see Fig.67)
- antislide strip (see Fig.68)
- pole support system and pole fixing brackets (see Fig.69)
- hybrid mechanical body (see Fig.78)
- polarization twist disk (see Fig.79)
- 2 ODUs with O–rings and devices for ground connection.
18.3 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)
• N.2 13 mm torque wrench
• N.1 15 mm torque wrench
106 AL - MN.00142.E - 009
• N.1 17 mm torque wrench
• N.1 3 mm Allen wrench
• N.1 2.5 mm Allen wrench
18.4 INSTALLATION PROCEDURE
Installation procedure proceeds according with the following steps:
1+0 version
1. installation onto the pole of the support system
2. installation of the antenna
3. installation of ODU
4. antenna aiming
5. ODU grounding
1+1 version
1. installation onto the pole of the support system
2. installation of the antenna
3. installation of hybrid circuit
4. installation of the two ODUs
5. antenna aiming
6. ODU grounding
18.4.1 Installation onto the pole of the support system and the antenna
Fig.67 – Set the antenna in such a position as to be able to operate on its rear side. Locate the five threadedholes around antenna flange. Mount centering ring onto antenna flange and tight it with 3 calibrated bolts.
Caution: centering ring should be mounted so that the screws do not stick out.
Define if the antenna will be mounted with vertical or horizontal polarization. Check that free drain holesstay at bottom side. Mount bolt type M10x30, in position A leaving it loose of 2 cm approx. With horizontalpolarization mount bolt type M10x30 in position D, leaving it loose of 2 cm approx.
Fig.68 – Mount antislide strip onto the pole. Place blocks as in Fig.68 following antenna aiming direction.Tighten the strip with screwdriver.
Fig.69 – Mount pole supporting system with relevant pole fixing brackets following antenna aiming direc-tion as indicated by arrow. Antislide strip should result at the center of supporting plate. Supporting systemshould lean against antislide clamp with the tooth as in Fig.70.
Position the antenna in such a way that bolt in position A or D of Fig.67 cross through hole E of Fig.71.Secure the support system to the pole by means of the pole fixing brackets and relevant fixing bolts.
Fig.72 – Rotate the antenna body until the remainder three antenna holes coincide with the three supportholes. Secure the antenna to the support by thightening the relevant passing through bolts.
AL - MN.00142.E - 009 107
18.4.2 Installation of ODU
1+0 version
1. Apply silicon grease e.g. RHODOSIL PATE 4" to the O–ring (4) of Fig.75 by protecting finger handswith gloves.
2. Bring the ODU with the two hands and position the ODU handle at the bottom side. The ODU handlecan assume position of Fig.73 depending on the polarization.
3. Position the ODU body near the support system and align ODU side flange to antenna side flange(see Fig.74). With respect to the flange alignment, turn the ODU body approx. 30° anti–clockwiseand then insert the ODU body into the support and search for alignment between reference toothon the support (see Fig.74) and ODU body reference tooth (see detail of Fig.75).
4. When alignment is achieved, turn the ODU body clockwise until "clack" is heard and the ODU rota-tion stops. Fig.76 and Fig.77 show ODU housing final position for vertical and horizontal polarizationrespectively.
5. Secure ODU body on the support system by tightening bolts (1) of Fig.74.
1+1 version
Fig.78 – Apply silicon grease, type "RHODOSIL PATE 4" to O–rings (1). Insert O–rings (1) and (6) into twistpolarization disk (2).
Vertical polarization
Fix the disk on hybrid flange placing marker (4), on disk, close to V mark.
Horizontal polarization
Fix the disk on hybrid flange placing reference (4), on disk, close to H mark.
Caution: Twist disk has two planes. Take care of position marker (4) on twist disk. The position of marker(4) plane should be in contact to hybrid like in figure. Tighten progressively and alternatively four screws(7) with four spring washers (8) with the following torque:
Tab.32
Fig.79 – Fix hybrid to support system with four bolts (1) taking care of RT1/RT2 position shown by labelsof Fig.79. Tighten progressively and alternatively four bolts (1).
18.4.3 ODU installation
The installation procedure of the two ODUs is the same.
1. Apply silicon grease e.g. RHODOSIL PATE 4" to the O–ring (4) of the Fig.75.9 by protecting fingerhands with gloves.
2. Bring the ODU with the two hands and position the ODU handle at the bottom side. For 1+0 theODU can assume position of Fig.73 depending on the polarisation. For 1+1 the handle ODU positionis always placed at the right side (horizontal polarization).
3. Position the ODU body near the support system and align ODU side flange to antenna side flange(see Fig.74). With respect to the flange alignment, turn the ODU body approx. 30° anti–clockwiseand then insert the ODU body into the support and search for alignment between reference toothon the support (see Fig.74) and ODU body reference tooth (see detail of Fig.75).
Frequencies Screw Tool Torque
from 18 to 38 GHz Allen screw M3 Allen key 2.5 mm 1 Nm
up to 15 GHz Allen screw M4 Allen key 3 mm 2 Nm
108 AL - MN.00142.E - 009
4. When alignment is achieved, turn the ODU body clockwise until "clack" is heard and the ODU rota-tion stops. Fig.76 and Fig.77 show ODU housing final position for vertical and horizontal polarizationrespectively for 1+0 version. Fig.80 shows ODU housing final position for 1+1 version.
5. Secure ODU body on the support system by tightening bolts (1) of Fig.74.
18.5 ANTENNA AIMING
Antenna aiming for 1+0 version and 1+1 version is the same. The antenna aiming devices allow to performthe following adjustments with respect to the starting aiming position:
• Horizontal ± 15° operating on the nut (3) shown in Fig.81, only after having loosen thenuts (7), (8), (9), (10) of Fig.82.
• Vertical ± 15° operating on vertical adjustment worm screw (2) shown in Fig.81 onlyafter having loosen nuts (1), (2), (11) of Fig.82 and (4) of Fig.81. For adjustment from 0° to +30° extract nut (1) Fig.82 and position it in hole(4), extract nut (2) Fig.82 and position it in hole (6). Operate on vertical ad-justment worm screw (2) after having loosen nuts (1), (2), (11) of Fig.82 and(4) of Fig.81. For adjustment from 0° to –30° extract nut (1) of Fig.82 and position it in hole(3), extract nut (2) of Fig.82 and position it in hole (5). Operate on verticaladjustment worm screw (2) after having loosen nuts (1), (2), (11) of Fig.82and (4) of Fig.81.
For vertical adjustment some markers, every 10°, are available on support. The bigger marker gives 0°starting aiming position. Once the optimum aiming position is obtained, tighten firmly the four nuts (1),(2), (11) of Fig.82 and (4) of Fig.81 for vertical adjustment and the four nuts (7), (8), (9), (10) of Fig.82for horizontal adjustment. Tighten with 15 mm wrench and 32 Nm torque.
18.6 GROUNDING
See Fig.83. On ODU grounding can be connected with the available bolt spring washer and flat washers asshown.
AL - MN.00142.E - 009 109
1. Antenna
2. Calibrated Allen screw
3. Centering ring
Fig.67 - Centering ring position
A
B C
D D
A B
C
A
B
C 1
2
3
Horizontal polarizationVertical polarization
3 mm Allen key2,5 Nm torque
110 AL - MN.00142.E - 009
1. Steel belt
2. Plastic blocks
Fig.68 - Antislide strip
1
2
AL - MN.00142.E - 009 111
1. Pole fixing brackets
2. Tooth
3. Bolt
4. Pole support system
Fig.69 - Support mount on pole
2
3 Antenna aiming direction
15 mm wrench32 Nm torque
1
3
1
3
3 3
3
112 AL - MN.00142.E - 009
1. Tooth
Fig.70 - Supporting plate position
Fig.71 - E hole
1
Antenna aiming direction
E
AL - MN.00142.E - 009 113
A, B, C, D: Bolt slots
Fig.72 - Antenna installation on pole support
Fig.73 - Position of the ODU handle depending on the polarisation for 1+0. For 1+1 the polarisation is always horizontal. Handle at the right side.
Vertical Horizontal
DA
B C
15 mm wrench32 Nm torque
Vertical Horizontal
114 AL - MN.00142.E - 009
H: Reference tooth
Fig.74 - Support system for ODU housing and reference tooth in evidence
1
1
1
H H
H H
H H
H H
13 mm wrench 6 Nm torque
1
AL - MN.00142.E - 009 115
Fig.75 - ODU body reference tooth
”N”
”BNC”
Ground bolt
ODU side flange
Reference tooth
O–ring
116 AL - MN.00142.E - 009
Fig.76 - ODU housing final position for vertical polarization
30°
AL - MN.00142.E - 009 117
Fig.77 - ODU housing final position for horizontal polarization
30°
30°
118 AL - MN.00142.E - 009
1. O–ring
2. Polarization twist disk
3. Hybrid mechanical body
4. Position marker of twist disk
5. Reference label for twist disk
6. O–ring
7. Allen screws
8. Spring washer
Fig.78 - Hybrid and twist disk
2
1
3
4
5
6
7
8
AL - MN.00142.E - 009 119
1. Bolts
2. Spring washer
Fig.79 - Hybrid mount on pole support
21
1
13 mm wrench 18 Nm torque
RT2
RT1
120 AL - MN.00142.E - 009
Fig.80 - ODU housing final position for 1+1 version
AL - MN.00142.E - 009 121
1. Marker
2. Vertical adjustment
3. Horizontal adjustment
4. Bolt
Fig.81 - Vertical and horizontal adjustments
21
3
4
Chiave da 15 mmCoppia 32 Nm
Chiave da 13 mm
Chiave da 13 mm
122 AL - MN.00142.E - 009
1, 2, 3, 4. Horizontal aiming block bolts
5, 6, 7. Vertical aiming block bolts
8, 11. Threaded hole for vertical aiming up to -30°
9, 10. Threaded hole for vertical aiming up to +30°
Fig.82 - Antenna aiming block
2
1 3
5
4
69
10
87
15 mm wrench 32 Nm torque
11
15 mm wrench 32 Nm torque
15 mm wrench 32 Nm torque
15 mm wrench 32 Nm torque
AL - MN.00142.E - 009 123
1. Bolt
2. Spring washer
3. Flat washer
4. Earth cable collar
5. Flat washer
Fig.83 - ODU grounding
12
4
3
5
124 AL - MN.00142.E - 009
19 INSTALLATION ONTO THE POLE OF THE ODU WITH INTEGRATED ANTENNA (KIT V32307, V32308, V32309)
19.1 FOREWORD
The description concerns pole mounting of ODU, in 1+0 and 1+1 version, using following installation kits:
- V32307 for ODU with frequency from 10 to 13 GHz
- V32308 for ODU with frequency from 15 to 38 GHz
- V32309 for ODU with frequency from 7 to 8 GHz
Differences regard the dimensions and the presence of the centring ring (see Fig.84):
- V32307 centring ring for antenna flange from 10 to 13 GHz
- V32308 centring ring for antenna flange from 15 to 38 GHz
- V32309 no centring ring (and relevant screws).
19.2 INSTALLATION KIT
Following installation kits are supplied with the equipment depending on different versions.
1+0 version
• 60 to 129 mm pole mounting kit:
- centring ring and relevant screws
- pole support system plus antenna (already assembled) and pole fixing brackets
- 1+0 ODU support and relevant screws
- ODU with O–ring and devices for ground connection
1+1 version
• 60 to 129 mm pole mounting kit:
- centring ring and relevant screws
- pole support system plus antenna (already assembled) and pole fixing brackets
- 1+0 ODU support
- hybrid and relevant screws
- polarization twist disk and relevant screws
- 2 ODUs with O–rings and devices for ground connection.
AL - MN.00142.E - 009 125
19.3 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)
• N.1 2.5 mm Allen wrench
• N.1 3 mm Allen wrench
• N.1 5 mm Allen wrench
• N.1 6 mm Allen wrench
• N.1 13 mm spanner
• N.2 17 mm spanner.
19.4 INSTALLATION PROCEDURE
Installation procedure is listed below:
1+0 version
1. antenna polarization
2. installation of the centring ring on the antenna
3. installation of 1+0 ODU support
4. installation onto the pole of the assembled structure
5. installation of ODU
6. antenna aiming
7. ODU grounding
1+1 version
1. antenna polarization
2. installation of the centring ring on the antenna
3. installation of 1+0 ODU support
4. installation onto the pole of the assembled structure
5. installation of hybrid
6. installation of ODUs
7. antenna aiming
8. ODU grounding.
126 AL - MN.00142.E - 009
19.5 1+0 MOUNTING PROCEDURES
19.5.1 Setting antenna polarization
Fig.84 – Set the antenna in such a position to operate on its rear side. Locate the four 2.5 mm
Allen screws around the antenna flange. Unscrew them (use 2.5 mm Allen wrench) and position the an-tenna flange according on: horizontal wave guide → vertical polarization, vertical wave guide → hori-zontal polarization. Screw again the four Allen screws (torque = 1Nm).
19.5.2 Installation of the centring ring on the antenna
Fig.84 - Set the antenna in such a position to operate on its rear side. Locate the three holes around theantenna flange. Mount the centring ring onto antenna flange and tight it with the 3 Allen screws M4 (use3mm Allen wrench, torque = 2Nm) .
19.5.3 Installation of 1+0 ODU support
Fig.84 - Mount the support onto assembled structure (pole support system plus antenna) using the four 6mm Allen screws (use 6 mm Allen wrench, torque = 18Nm). Two of the four screws, diagonally opposed,must be mounted with the two bushes around.
19.5.4 Installation onto the pole of the assembled structure
Fig.84 - Mount the assembled structure on the pole using the two pole fixing brackets and the four 17 mmscrews (use 17 mm spanner, torque = 13Nm); the heads of the screws are inserted on the antenna side,the four nuts and the springs between nut and brackets are inserted on bracket side.
19.5.5 Installation of ODU (on 1+0 support)
Fig.85 - Apply silicon grease (e.g. RHODOSIL PATE 4") on the O–ring by protecting fingers with gloves.
Fig.86 - Bring the ODU with the two hands and position the ODU handle at the bottom side.
The handle can assume the positions shown in the figure depending on the polarization. Position the ODUbody near the support and align the wave guide of the ODU to the Wave guide of the antenna: respect tothe position of wave guide alignment, turn the ODU body approx. 30° counter–clockwise and then insertthe ODU body into the support and search for matching between reference tooth on the support (seeFig.87) and reference tooth on the ODU body.
Fig.88 - When alignment of the references teeth is achieved, turn the ODU body clockwise until "clack" isheard and rotation is stopped. In figure are shown ODU final position for both polarizations.
Fig.87 - When ODU positioning is over, secure ODU body on the support by tightening bolts (use 17mmspanner, torque = 6Nm).
AL - MN.00142.E - 009 127
19.5.6 Antenna aiming
Antenna aiming procedure for 1+0 version or 1+1 version is the same.
Horizontal aiming: ±5° operating on the 17 mm nut shown in Fig.89 with a 17 mm spanner, only afterhaving loosen the two 17 mm nut on the pivot.
Vertical aiming: ±20° operating on the 13 mm nut shown in Fig.89 with a 13 mm spanner, only after havingloosen the three 13 mm nut on the pole support.
Once optimum position is obtained, tighten firmly all the nuts previously loosen.
19.5.7 ODU grounding
ODU grounding is achieved with:
• M8 screw without washers
• M6 screw with washer
as shown in Fig.90.
19.6 1+1 MOUNTING PROCEDURES
In further page are explained all the mounting step not already discussed in " 1+0 MOUNTING PROCE-DURES"
19.6.1 Installation of Hybrid
Fig.91 – The polarization twist disk must be always fixed on hybrid flange.
Apply silicon grease (e.g. RHODOSIL PATE 4") on the O–rings by protecting fingers with gloves. Bring thepolarization twist disk with the position marker down. Insert the O–ring into polarization twist disk.
Vertical polarization: fix the twist disk on hybrid flange placing the marker of the disk towards V mark.
Horizontal polarization: fix the twist disk on hybrid flange placing the marker of the disk towards H mark.
Tighten progressively and alternatively the four screws and spring washer with following torque:
Tab.33
Fig.92 - Fix hybrid body to 1+0 support with four 13 mm bolts (use 13 mm spanner, torque = 18 Nm),tighten progressively and alternatively the bolts.
Frequencies Screw Tool Torque
from 18 to 38 GHz Allen screw M3 Allen key 2.5 mm 1 Nm
up to 15 GHz Allen screw M4 Allen key 3 mm 2 Nm
128 AL - MN.00142.E - 009
19.6.2 Installation of ODUs (on hybrid for 1+1 version)
For both ODUs.
Fig.85 – Apply silicon grease e.g. RHODOSIL PATE 4" to the O–ring by protecting fingers with gloves.
Fig.86 – Bring the ODU with the two hands and position the ODU handle at the bottom side.
The handle can assume the positions shown in the figure depending on the polarization. Position the ODUbody near the support and align the wave guide of the ODU to the wave guide of the hybrid: respect to theposition of wave guide alignment, turn the ODU body approx. 30° counter–clockwise and then insert theODU body into the support. For 1+1 system the handle of the ODU is always positioned on the right. Thepolarization twist disk on the hybrid matches the antenna polarization.
Fig.93 – When alignment of the reference teeth is achieved, turn the ODU body clockwise until "clack" isheard and the rotation stops. In figure are shown ODUs final position.
Fig.89 – When ODU positioning is over, secure ODU body on the support by tightening bolts (use 17 mmspanner, torque = 6 Nm).
Warning: Internal codes (e.g. installation items, antennas, PCB) are here reported only as example. TheManufacturer reserves the right to change them without any previous advice.
AL - MN.00142.E - 009 129
Fig.84 - 1+0 pole mounting
Four 13mmscrews
Two bushes
1+0 support
Three 3mm Allen screws (not present in V32309)
Centring ring(not present in V32309)
Antenna
130 AL - MN.00142.E - 009
Fig.85 - ODU body reference tooth
”N”
”BNC”
Ground bolt
ODU wave guide
Reference tooth
O–ring
AL - MN.00142.E - 009 131
Fig.86 - Position of the ODU handle depending on the polarisation for 1+0. For 1+1 the polarisation is always horizontal. Handle at the right side.
1. 6 mm Allen screw
2. Bush (diagonally placed)
3. 17 mm Tightening bolts (max torque = 6 Nm)
4. Reference point for horizontal polarization
5. Reference point for vertical polarization
Fig.87 - 1+0 support
Vertical Horizontal
1
1
2
23
1
1
3
4
5
4
5
132 AL - MN.00142.E - 009
Fig.88 - ODU housing final position for both polarization
1+0 ODU with handle on the right:horizontal polarization
1+0 ODU with handle on the right:vertical polarization
AL - MN.00142.E - 009 133
Fig.89 - Antenna aiming
1. Bolt
2. Spring washer
3. Flat washer
4. Earth cable collar
5. Flat washer
Fig.90 - ODU grounding
Horizontal aiming: two17mm block screws
Vertical aiming: three13mm block screws
Pole support
17mm nut for horizontaladjustment of antenna
Internal 5mm Allenscrew for vertical
adjustment of antenna
12
4
3
5
134 AL - MN.00142.E - 009
1. O–ring
2. Polarization twist disk
3. Hybrid mechanical body
4. Position marker of twist disk
5. Reference label for twist disk
6. O–ring
7. Allen screws
8. Spring washer
Fig.91 - Hybrid and twist disk
2
1
3
4
5
6
7
8
AL - MN.00142.E - 009 135
Fig.92 - Hybrid installation
Fig.93 - 1+1 ODUs installation
136 AL - MN.00142.E - 009
20 INSTALLATION ONTO THE POLE OF THE 4 GHZ ODU WITH SEPARATED ANTENNA (KIT V32323)
20.1 INSTALLATION KIT
1+0 version
• Anti–sliding bracket
• ODU pole support and relevant screws
1+0 version
• Anti–sliding bracket
• ODU pole support and relevant screws
• hybrid and relevant screws
• Hybrid–ODU connecting cables
20.2 REQUIRED TOOLS FOR MOUNTING (NOT SUPPLIED)
• N.2 13 mm spanner
• N.1 15 mm spanner
• N.1 17 mm spanner.
20.3 INSTALLATION PROCEDURE
Installation procedure is listed below:
• 1+0/1+1 version: pole installation of the support
• 1+1 version: installation of the hybrid on the support
• installation of the ODU on the support
• ODU grounding and connection of the cables to the hybrid and antenna
1+0/1+1 version: pole installation of the support
Fig.94 - Install anti–sliding device (1) around the pole. The position of the plastic blocks depends on theposition of the support (2) and of the relevant hooking pin (3).
AL - MN.00142.E - 009 137
Hook the support to the plastic blocks by means of the hooking pin. Insert to the four screws (4) in therelevant holes, set the two brackets (5) and clamp them around the pole tightening the four nuts (6) (tight-ening torque = 32 Nm).
Cover the projecting bits of the screws using the relevant red covers (7). The two holes (8) house the twotightening screws of the hybrid (only for 1+1 version).
1+1 version: hybrid installation on the support
Fig.95 – Set the hybrid (1) on the support (2) in such a way that the connectors are downward and thatthe holes on the lower side of the hybrid match with the corresponding holes (8) of the Fig.94.
Insert the two screws (3) (tightening torque = 7.3 Nm) and tighten the hybrid to the support.
ODU installation on the support
Locate the part of the support more suitable for the installation of the ODU: both the parts can be used(1+0 version).
Fig.95 – Locate the four slots (4) on the support (2).
Fig.96 – Keeping the knob of the ODU1 downward, partially screw the two screws (2) into the two upperholes of the ODU, on N connector side.
Hook the heads of the two screws (2) of the Fig.96 into the slots (4) of the Fig.95.
Insert also the remaining screws (2) into the holes (3). Tighten all the four screws (2) (tightening torque= 7.3 Nm).
Put the sun–cover (5) over the ODU (1) and fix it to the knob of the ODU by means of the supplied strip.In case of 1+1 version, repeat the whole procedure for the second ODU.
ODU grounding and connection of the cables to hybrid and antenna
Fig.97 – Tighten the grounding cable of each ODU by means of grounding bolt (1) (tightening torque = 7.3Nm) and the relevant washer.
For the connection of the RF cable follow the label on the bottom of the hybrid: ODU1 (RT1) is that con-nected to RIM1 of IDU, ODU 2 (RT2) is that connected to RIM2 of IDU.
138 AL - MN.00142.E - 009
Fig.94 - Pole installation of the support
4
4
4
4
8
2
3
6
7
67
5
5
1
AL - MN.00142.E - 009 139
Fig.95 - Installation of the hybrid on the pole support (only for 1+1 version)
2
3
1
4
4
140 AL - MN.00142.E - 009
Fig.96 - Installation of the ODU on the support
5
231
AL - MN.00142.E - 009 141
Fig.97 - ODU grounding and connection of the cables to hybrid and antenna
1
1
RT2
RT1
142 AL - MN.00142.E - 009
AL - MN.00142.E - 009 143
Section 4.LINE-UP
21 LINE–UP OF THE RADIO HOP
21.1 LINE–UP OF THE RADIO HOP
The line–up consists of the following steps:
• on site radio terminal installation (perform user connections and ODU installation as described inthe relevant chapters)
• equipment switch–on (operate the ON/OFF switch on the IDU front)
• antenna alignment for maximum received RF signal level
• network element configuration
• check measurements.
21.1.1 Antenna alignment and received field measurement
Purpose of antenna alignment is to maximize the RF received signal level.
Proceed as follows:
• connect a multimeter to BNC connector on the ODU for AGC measurement
• adjust antenna pointing as soon as the maximum AGC voltage value is achieved.
The relationship between AGC voltage and received field is shown by Fig.98.
The received field level has a tolerance of ±4 dB in the full temperature range.
144 AL - MN.00142.E - 009
21.1.2 Network element configuration
A factory default address is assigned to each network element that must normally be reconfigured on sitefollowing the network administrator rules.
To this purpose it is required to connect the PC, where the SCT/LCT program has been installed, to thenetwork interfaces.
This has to be done via USB or Ethernet cable.
Warning: the checks that follow require a good knowledge of the program use.
The description of each menu and relevant windows are given by the program itself as help on line.
Run the program and perform the connection to equipment by choosing from menu "Option" the connec-tion made via USB cable.
Perform the login to the equipment by entering:
• Equipment IP address4
• User ID (default: SYSTEM)
• Password: (default: SIAEMICR)
Proceed to program what above mentioned following this path:
• IP Address: select menu Equipment from the menu bar and then Communication Setup → PortConfiguration. Enter the required port addresses in the available communication ports. Press ? fordetails.
• Routing Table and Default Gateway: select menu Equipment from the menu bar and then Com-munication Setup → Routing table: enter the routes or default gateway if necessary. Press ? fordetails. Warning: the routing policy depends on the routing type: manual IP/OSPF/IS–IS. The relevant rout-ing rules must be normally given by network administrator.
• Remote Element Table: select menu Tools from menu bar and then Subnetwork ConfigurationWizard. Station name and remote element table must be assigned following description of the con-textual help on–line (?).
• Agent IP Address: select menu Equipment and then Properties. Assign the address in accordanceto the address of the remote element you want to reach.
21.1.3 Radio checks
It is advisable to perform the following measurements to check the correct operation of the radio hop:
• Transmitted power
• Received power
• RF frequency
• BER measurement
All these checks make use of the SCT/LCT program.
• Transmitted power, received RF level, RF frequency
- Run SCT/LCT program and then perform the connection to the equipment you want to check.
- Make double click on the select equipment until main RADIO PDH–AL window is shown.
- On top of the window Tx/Rx power and frequency values are displayed. In case of Tx power andfrequency setup proceed to Branch 1/2 and Power/Frequencies submenus.
• BER measurement
- Run SCT/LCT program and then perform the connection to the equipment you want to check.
4 If the connection is made via USB cable, the IP address is automatically achieved.
AL - MN.00142.E - 009 145
- Make double click on the selected equipment until main RADIO PDH–AL window is shown.
- On the left side select BER1/2 measure. In alternative it is possible to use the PRBS function ifone or 2 Mbit/s line is free.
- Perform the BER measurement and check that values comply with the requirements.
Fig.98 - Detected voltage versus Rf received signal
–100 –80 –60 –40 –20
3
2,25
1,5
0,75
0 dBm
V
–70 –50 –30
1,125
1,875
2,625
146 AL - MN.00142.E - 009
22 LINE–UP OF ETHERNET TRAFFIC (FOR IDU WITH ETHERNET MODULE ONLY)
22.1 GENERAL
This paragraph deals with line–up of V12252 Ethernet module with details of SCT/LCT program related onlyto Ethernet application.
Assuming that the radio link is already in service, with correct frequency, output power and correct antennaalignment, the line up procedure for different kinds of connection set up of a radio link AL, equipped withLIM Ethernet/2 Mbit/s module, is hereafter described:
1. Local Lan–1 port to remote Lan–1 port connection LAN per port, see Fig.99
2. Local Lan–1 port to remote Lan–1 port connection with only VLANs
3. 3 to 1 port connections, see Fig.111.
Settings here below are intended to be done both into local and remote radio equipment.
22.2 LOCAL LAN–1 PORT TO REMOTE LAN–1 PORT (TRANSPARENT CONNECTION LAN PER PORT)
Settings for Untagged and Tagged Traffic
Fig.99 - Local Lan–1 port to remote Lan–1 port connection
The line–up of Ethernet traffic is made with the help of SCT/LCT program.
Please refer to Fig.100. First selection is Ethernet throughput and modulation scheme, in this example weselect 16 Mbit/s and modulation 16QAM (max throughput and modulation scheme depend on terms of li-cence provided by Siae Microelettronica).
Select configuration 1+0 or 1+1 according system requirements. Inside LCT, select Tributary window. If 2Mbit/s tributaries are needed, inside the Tributary window it is possible to activate a 2 Mbit/s input/outputon the front panel. When the activation of required 2 Mbit/s tributaries is completed, all the others 2 Mbit/sstreams are automatically used for the Ethernet traffic. For instance with a 8x2 Mbit/s capacity, if we usetwo 2 Mbit/s the capacity assigned to Ethernet circuits is automatically set to 6x2 = 12 Mbit/s full duplex.
Radio
port 1
switch
Lan–1
Radio
port 1
switch
Lan–2
Lan–3
Nx2Mbit/s
Local
Lan–1
Lan–2
Lan–3
Nx2Mbit/s
Remote
AL - MN.00142.E - 009 147
Fig.100 - Selection of Ethernet Throughput
See Fig.101 for General settings for the switch. All the used ports must be Enabled, so enable Lan–1 andInternal Port, see Fig.102.
The other ports should be disabled. The correct cable crossover arrangement must be selected too (seeFig.102). At the end of Line–up, enable LLF if needed.
For Untagged traffic, connections are done with Lan per port selections. Referring to Fig.103 incoming traf-fic at Lan–1 exits at Internal Port and into Fig.105 incoming traffic at Internal Port exits at Lan–1 port. Thisconnection are done for all Untagged traffic and all Tagged packets with Vlan Id not described into VlanConfiguration Table.
If Vlan Configuration Table is blank all Tagged traffic follows the rules of Lan per port.
Possible selections of Ingress Filtering Check:
1. Disable 802.1q: no check of Virtual Lan tag is made and all packets follow Lan per port settings
2. Fallback: if Tagged packets have their Vlan Id into Vlan Configuration Table they follow the connec-tion described into the table, otherwise they follow the Lan per port settings as Untagged packets
3. Secure: no Untagged packet transits; only Tagged packets with Vlan Id listed into the table cantransit. For all pass configuration, Disable 802.1 should be selected. With Egress Mode as Unmodified the outgoing packets at Lan–1 port exit Untagged or Taggedexactly as they were Untagged or Tagged at the incoming port.
148 AL - MN.00142.E - 009
Fig.101 - Switch general settings
Fig.102 - Lan–1 interface settings
Link LossForwardingHisteresys
Click here for Port mapping andVLAN configuration table
Output policyfor Taggedpackets: Level2 priority, ifused, definedfor all the portsfor incomingpacketsalready Tagged
AL - MN.00142.E - 009 149
Fig.103 - Vlan settings for Lan–1
Fig.104 - Priority setting for Lan–1 and Internal Port
IncomingUntaggedpackets at
Lan–1 are sentinto output partqueue followingthis selection.
In this examplepackets areinserted into
queue 0.
150 AL - MN.00142.E - 009
With Priority disabled no check is done into 802.1p priority Tag. All types of packets go into Default PriorityQueue.
Fig.105 - Vlan settings for Internal Port
Fig.106 - Vlan Configuration Table
AL - MN.00142.E - 009 151
22.3 LOCAL LAN–1 PORT TO REMOTE LAN–1 PORT (WITH VLANs)
Settings are done to transfer only Tagged traffic within Vlans.
We want that Vlan 701, 702, 710 and 1, 2, 3 can pass into the radio link and all the other Tagged or Untaggedpackets should be blocked.
The line up of Ethernet module is made with the help of LCT/SCT program. Please refer to Fig.100. First selec-tion is Ethernet throughput and modulation scheme, in this example we select 16 Mbit/s and modulation 16QAM(max throughput and modulation scheme depends on terms of licence provided by Siae Microelettronica). Se-lect configuration 1+0 or 1+1 according system requirements.
Inside LCT, select tributary window. If 2 Mbit/s tributaries are needed, inside the tributary window it is possibleto activate a 2 Mbit/s input/output on the front panel. When the activation of required 2 Mbit/s tributaries iscompleted, all the others 2 Mbit/s streams are automatically used for the Ethernet traffic. for instance with a16 Mbit/s capacity if we use two 2 Mbit/s the capacity assigned to ethernet circuits is automatically set to 16–2x2 = 12 Mbit/s full duplex.
See Fig.101 for general settings for the switch. All the used ports must be enabled, so enable Lan–1 and InternalPort, see Fig.102. The other ports should be disabled. The correct Cable crossover arrangement must be se-lected too. Enable LLF if needed, only at the end of line up.
Vlan settings for Lan–1 and Internal Port should be like in Fig.107 with Ingress Filtering Check as Secure andEngress Mode as Tagged. With this setting only Tagged packets with Vlan ID listed into the Vlan ConfigurationTable can transit. All Untagged packets are blocked at the incoming port and outgoing Tagged packets don’tchange.
A packet with Vlan ID XX can enter into the switch only if Incoming Port (Ingress port) is a member of the VlanXX, same packet will exit only from ports (Engress Port) which are members of Vlan XX. Vlan membership isdescribed into Vlan Configuration Table. A port can be member of no one, one or more Vlans. See Fig.108 forVlan Configuration Table settings for our example.
Fig.107 - Virtual Lan input and output settings at Lan–1 port
152 AL - MN.00142.E - 009
Fig.108 - Vlan Configuration Table with some Vlans
Tagged incoming packet can be treated with FIFO policy or on the basis of their 802.1p priority tag andToS/DSCP value for IP packets. There are 4 queue at each output port. The decision about to which outputqueue to send a packet is defined into Ethernet switch window selections for 802.1p tag. Into Ethernetswitch window it is possible to select ToS/DSCP button to open window ToS/DSCP, in this window eachincoming ToS/DSCP value is associated with an output queue so it is possible to change the priority of theincoming packet.
When no info on priority is available, the packet is sent to Default Priority Queue using FIFO policy.
Into Lan–1 window select Priority (802.1q), into priority box there are some selections: with "Disable"switch doesn’t look at priority tag; with 802.1p switch looks at Tag 802.1p only; with IpToS for IP packetsonly switch looks to ToS/DSCP identifier (into IP frame) only; with 802.1p – IpToS switch looks first to802.1p tag and secondly to ToS/DSCP, see Fig.110; with IpToS–802.1p switch looks first to ToS/DSCP andsecondly to Tag 802.1p.
Note: with IpToS switch looks to IP packet and ToS/DSCP doesn’t matter if the packets are tagged with802.1p or not.
In this example incoming tagged are tagged and it is necessary to transfer the packets with no change sothey must exit from output ports tagged, see Fig.109 and Fig.110.
AL - MN.00142.E - 009 153
Fig.109 - Add a new Vlan ID to Vlan Configuration Table with output tagged
Fig.110 - Layer 2 and Layer 3 priority management
IncomingUntaggedpackets at
Lan–1 are sentinto output partqueue followingthis selection.
In this examplepackets areinserted into
queue 0.
154 AL - MN.00142.E - 009
22.4 3 TO 1 PORT CONNECTIONS
Fig.111 - 3 to 1 port connections
In this example 3 local port must communicate with corresponding remote ports. All the ports share thesame radio channel but traffic originated and directed to Lan1 should be kept separated from traffic fromLan2 and Lan3 and viceversa.
Lan–1 to Lan–1 connection should transfer tagged packets with Vlan 1, 701, 760 and untagged packets.Unspecified tagged packets must be stopped. Lan–2 and Lan–3 have the same requirements. For all con-nections IP packets with high priority TOS should transferred at minimum delay.
22.5 3 TO 1 PORT CONNECTIONS, SETTINGS FOR UNTAGGED TRAF-FIC
The line–up of Ethernet traffic is made with the help of LCT/SCT. Please refer to Fig.99.
First selection is Ethernet throughput and modulation scheme, in this example we select 16 Mbit/s andmodulation 16QAM (max throughput and modulation scheme depend on terms of licence provided by SiaeMicroelettronica). Select configuration 1+0 or 1+1 according system requirements.
Inside LCT, select Tributary window.
If 2 Mbit/s tributaries are needed, inside the tributary window it is possible to activate a 2 Mbit/s input/out-put on the front panel. When the activation of required 2 Mbit/s tributaries is completed, all the others 2Mbit/s streams are automatically used for the Ethernet traffic. For instance with a 8x2 Mbit/s capacity ifwe use two 2 Mbit/s the capacity assigned to Ethernet circuits is automatically set to 6x2 = 12 Mbit/s fullduplex.
Vlan Configuration Table will be defined in order to group traffic from Lan–1, Lan–2, Lan–3 to Port1. All theused ports must be Enabled.
Untagged traffic transits only if the selection for Ingress Filtering Check is disabled at each input port anda separated Vlan for Untagged traffic is set up for each port. See Fig.101, Fig.102, Fig.111, Fig.112 andFig.113.
Each port of the switch must be associated with a different Default VLAN ID in order to maintain the trafficcoming from different separated LANs, Lan–1 with default VID 3301, Lan–2 with default VID 3302, Lan–3with default VID 3303, for Lan–1 see Fig.113 and Fig.114.
The correct Cable Crossover arrangement must be selected too.
ALradio
port 1
switch
Lan–1
ALradio
port 1
switch
Lan–2
Lan–3
Nx2Mbit/s
Local
Lan–1
Lan–2
Lan–3
Nx2Mbit/s
Remote
AL - MN.00142.E - 009 155
Fig.112 - Input and output setting for VLANs at Lan–1 port
Fig.113 - Output port properties for VLAN 3301
156 AL - MN.00142.E - 009
Fig.114 - Typology 3 to 1, Virtual Lan Configuration
With the above settings inside the VLAN configuration Table only Untagged traffic is forwarded accross thebridge.
The same settings should be done inside the remote equipment. The above example shows the Virtual LanConfiguration Table in case of a link carrying the traffic of 3 independent LAN’s connected to Lan–1, Lan–2, Lan–3, which is split at the remote end among the outgoing Lan–1, Lan–2, Lan–3 ports, while using acommon radio link.
To prioritize some IP packets with high ToS/DSCP value it is possible to open PToS/DSCP window fromEthernet switch window and select the values of ToS for which the packet is sent to high priority Queue,see Fig.115.
Fig.115 - Output Queue selection on the basis of TOS/DSCP priority
Default VID assigned byuser to each port
Vlan 3301, 3302, 3303 are allowed to exit at Port1with tags (Tagged). Different default Tag’s allow to
keep separate the traffic from Lan1, Lan2 andLan3 exiting at Port 1. At the remote end the traffic
is split and forwarded from Port1 to Lan1, Lan 2and Lan3 without Tag to preserve the original
format.
TOS value description DSCP value description
Packetswith AF43
prioritylevel willgo into
Queue 3 atall ports
AF43 now goes to Queue 3, with thisbutton AF43 will go to Queue 2
AL - MN.00142.E - 009 157
22.6 3 TO 1 PORT CONNECTIONS, SETTINGS FOR TAGGED AND UN-TAGGED TRAFFIC
If we want VLAN with Tag 701, 702 and 703 to transit between Lan–1 and Port–1 it is necessary to definePort 1 and Lan 1 as members of VLAN1, 701, 760 (see Fig.116 for VLAN 701 and do the same for VLAN1,760).
The VLAN Configuration Table will look like Fig.117.
For Lan–2 and Lan–3 we cannot use the same Vlan if we want to maintain traffic from Lan 1, 2, 3 separated.We must change the number of incoming Vlan for instance of 1, 701, 760 use 2001, 2701, 2760 for Lan–2 and 3001, 3701, 3760 for Lan–3. Connected equipment to Lan–2 port should be reprogrammed to useVlan 2001, 2701, 2760.
Connected equipment to Lan–3 port should be reprogrammed to use Vlan 3001, 3701, 3760.
To prioritize Ip packets with high ToS/DSCP value it is possible to open PToS/DSCP window from Ethernetswitch window and select the values of ToS for which the packet is sent to high priority Queue 3, seeFig.115. The same should be done inside the remote equipment.
Fig.116 - Output properties of VLAN 701
158 AL - MN.00142.E - 009
Fig.117 - Typology 3 to 1, Virtual Lan Configuration Table with Vlan
22.7 3 TO 1 CONNECTIONS: EXAMPLES OF PRIORITY MANAGEMENT
Example 1: To assign to Lan–1 and Lan–3 low priority and to Lan–2 high priority, while wanting Taggedand Untagged to be treated in a fair manner on each queue do as follow: select Priority Disable for Lan–1,Lan–2 and Lan–3; select Default Priority Queue equal to Queue 0 for lan–1 and Lan–3 (see Fig.104). SelectDefault Priority Queue equal to Queue 3 for Lan–2 (as in Fig.118).
Outgoing Untagged packets will take priority tag defined into input port, in this case 0. Tagged frames keeptheir tag.
Example 2: Wanting tagged frames to be treated according their actual priority and untagged packets withlow priority, all inputs should be configured as in Fig.Fig.119.
Layer 2 Priority assignment is not modified if inside the second folder of the Lan–X (1, 2, 3) configurationwindow Untagged Frame Egress Mode = Unmodified is selected as in Fig. Fig.120.
AL - MN.00142.E - 009 159
Fig.118 - Queue selection
Impostando questa cartella, i pacchetti senza tag arrivati alla Lan–2 sonotrasmessi alle Code Porte di output. In questo esempio tutti i pacchetti entranti
nella Lan–2 vengono inseriti nella Coda di output 3 delle porte di output. Priorità di Input: quando non è selezionato Disable, le trame con tag sono
trasmesse alle code 0,1,2,3 secondo il valore di priorità porta di destinazione;con Disable selezionato per questa porta la commutazione usa la Default
Priority Queue per trame con tag e senza tag, e senza modifica reale di tagnelle trame entranti con tag.
160 AL - MN.00142.E - 009
Fig.119 - Management of tagged frames according with their priority tag
AL - MN.00142.E - 009 161
Fig.120 - Incoming packets at Lan–1 will exit to other ports unchanged according their incom-ing status.
162 AL - MN.00142.E - 009
AL - MN.00142.E - 009 163
Section 5.MAINTENANCE
23 PERIODICAL CHECKS
23.1 GENERAL
Periodical checks are used to check correct operation of the radio equipment without the presence of anyalarm condition.
The SCT/LCT programs running on the PC are used for the purpose.
23.2 CHECKS TO BE CARRIED OUT
The following checks must be carried out:
• check of the transmitted power;
• check of the received field strength (the reading must match the value resulting from hop calcula-tions);
• check of bit error rate and hop performances.
For checking procedures, please refer to SCT/LCT program and relevant help–on line.
164 AL - MN.00142.E - 009
24 TROUBLESHOOTING
24.1 GENERAL
The AL equipment consists of the following replaceable parts:
• IDU
• ODU
Purpose of the troubleshooting is to pinpoint the faulty part and replace it with spare.
Warning: the replacement of a faulty IDU with spare causes the spare IDU to be re–programmed. To thepurpose refer to chapter 19 for the relevant procedure.
24.2 TROUBLESHOOTING PROCEDURE
Troubleshooting starts as soon as one of the following alarm condition: IDU/ODU/REM is switched ON onthe IDU panel from (see Fig.121) or alarm messages are displayed by managers SCT/LCT. Two methods are used to troubleshoot the cause of fault:
• loop facilities
• alarm message processing using the manager SCT/LCT
24.2.1 Loop facilities
The equipment is provided with different loops that help locate the faulty part.
Warning: the majority of loops causes the traffic to be lost.
The available loops are the following:
• local tributary loops: usually used to test the cables interfacing the equipment upstreams
• remote tributary loops: usually used to test the two direction link performance making use of anunused 2 Mbit/s signal.
• baseband loop: it permits to test the LIM circuits
• IDU loop: it permits to test the complete IDU (optional)
• RF loop: it permits to test the complete radio terminal.
AL - MN.00142.E - 009 165
24.2.2 Alarm messages processing
When an alarm condition occurs, the equipment generates a number of alarm messages that appear onthe SCT windows ie: log history area and equipment view current alarm. Investigation on the alarm mes-sage meaning permits to troubleshoot the faulty module.
Alarm message organisation
The alarms (traps) are organized as alarm grouping relevant to a specific functions performed by the equip-ment.
The alarm grouping is available only in the view current alarm submenu.
What follows is the list of the alarm grouping:
• COMMON – alarms which are not related to a specific part of the equipment but relevant to the linkas EOC radio link alarm or link telemetry fail. If these alarms are ON the link is lost. Investigationmust be made on a possible bad propagation or equipment failure. See the condition of the othersalarm grouping.
• LIM – This grouping may generate alarms for the following causes:
- external fault: tributary loss signal
- LIM failure: i.e. multiplexer/demultiplexer failure or modulator/demodulator failure.
• RIM – This grouping may generate alarms for the following causes:
- external fault: demodulator fail alarm and local ODU alarm are generated when the ODU be-comes faulty.
- RIM failure – power supply alarm along with cable short/open alarms or modulator/demodulatoralarms are activated.
• RT – This grouping may generate alarms for the following causes:
- external fault: Rx power low alarm is generated given by a bad propagation or by a faulty remoteterminal.
- ODU failure: PSU fail alarm or RF VCO alarm or RT IF alarm is activated. If this happens, replacethe ODU.
• UNIT – This grouping generates alarms when one of the units, the equipment consists of, is faultyor does not respond to the controller polling. Replace the faulty unit.
• CONTROLLER – There is not an alarm message relevant to a controller module failure. An alarmcondition causes Led IDU to steady lights up.
Fig.121 - IDU front
48V
+ –
Trib. 1–2–3–4
Trib. 5–6–7–8
PSLCTQ3 USER IN/OUT
RTESTAL
166 AL - MN.00142.E - 009
25 EQUIPMENT CONFIGURATION UPLOAD/SAVE/DOWNLOAD. PARAMETER MODIFICATION AND CREATION OF VIRTUAL CONFIGURATIONS.
25.1 SCOPE
This chapter describes the procedure to create configuration files.
Equipment configuration files must be used in case of replacing a faulty IDU with a spare. To this purposeit is necessary to upload, from each network element, equipment configurations and save them on threeconfiguration files.
It is advisable to do it upon the first installation. Configuration file download on the spare CONTROLLERpermits to restore previous operating condition. It is also possible to create virtual configuration withoutbeing connected to equipment.
25.2 PROCEDURE
To configure the spare IDU the following must be uploaded/saved on the file/downloaded:
• General equipment configuration
• Addresses and routing table
• Remote element table
To do it, run the SCT/LCT program (see relevant documentation available on line) until "Subnetwork CraftTerminal" application window is displayed.
25.2.1 General equipment configuration
Upload and save
1. Select Open Configuration Template from Tools menu following this path: Tools → EquipmentConfiguration Wizard → File → Open Configuration Template. The system will show Template Selection window.
2. Choose from Template Selection window the type of equipment and version (for instance radio PDHAL: 2x2, 4x2, 8x2, 16x2 Mbit/s) from which you want to make the upload.
3. Press OK. The system will display the Configuration Wizard window referring to the selected type of equipmentand version (example: radio PDH AL: 2x2, 4x2, 8x2, 16x2 Mbit/s)
4. Press Upload push button and select Get Current Type Configuration from Equipment. The system will display the Upload Configuration File window. The window will show the equipmentlist.
AL - MN.00142.E - 009 167
5. Select the equipment you wish to upload a configuration file from (normally the local equipment)by activating the relevant box.
6. Press OK. The system displays the Communication Status window where is pointed out:
- the operation status: upload in progress/complete.
- errors area: where error messages relevant to possible abort of the operation are displayed.
At the end of the operation by pressing OK, the system displays, the uploaded equipment param-eters present into the Configuration Wizard window.
7. Save the uploaded configuration into a file by selecting Save File As command from File → Save→ Save File As.
The system will display Save This Config. File.
Type the file name into the proper box (with "cfg" extension) and set the path to be used to savethe file.
8. Press Save push button to finish.
Download
After having installed the spare IDU proceed as follows:
1. Select Open File from Tools menu following this path: Tools menu → Equipment ConfigurationWizard → File → Open → Open File.
The system will display Select a Config. File window.
2. Select the wanted file and open it by pushing Open push button. The system will display the filecontent.
3. Press Download push button and select Configure Equipment as Current File.
4. Activate the box relevant to the equipment you wish to download configuration file to (normally thelocal equipment) and select Configure Equipment as Current File.
5. Press OK.
The system displays the Communication Status window where is pointed out:
- the operation status: upload in progress/completed
- errors area: where error messages relevant to possible abort of operation are displayed.
6. Press OK to finish.
25.2.2 Addresses and routing table
Upload and save
1. Select Open Address Configuration Template from Tools menu following this path: Tools menu → Equipment Configuration Wizard → File → Open → Open Address Configuration Tem-plate.
The system will show the mask of the Address Comfiguration Template.
2. Press Upload push button and select Get Current Type Configuration from Equipment.
The system will display the Upload Configuration File window.
3. Select the equipment you wish to upload a configuration from (normally the local equipment).
4. Press OK.
The system displays the Communication Status window where is pointed out:
- the operation status: upload in progress
- errors area: where error messages relavant to possible abort of the operation are displayed.
168 AL - MN.00142.E - 009
At the end of the operation, the system displays, the equipment parameter present into the Con-figuration Wizard window.
5. Save the uploaded configuration into a file by selecting Save File As command from File → Save→ Save File As
The system will display the Save This Config. File window. Into the proper boxes type the file name(with "cfg" extension) and set the path to be used to save the file.
6. Press Save push button to finish.
Download
1. Select Open File command from Tools menu following this path: Tools Equipment ConfigurationWizard → File → Open → Open File.
The system will display Select a Config. File window.
2. Select the wanted file and open it by pushing Open push button. The system will display the pa-rameters contained into the file.
3. Press Download push button and select Configure Equipment as Current File.
4. Activate the box relevant to the equipment you wish to download configuration file to (normally thelocal equipment).
5. Press OK.
The system will display Download Type Selection window. Activate boxes IP port addresses config-uration e Routing table . If OSPF facility is enabled, you can only select Standard (IP/Communi-cation/OSPF) Settings.
6. Press OK.
The system will show a warning indicating the possibility to procede the download or not.
7. Press OK.
The system will show the Download in progress.
8. At the end of the download will be shown the file content.
25.2.3 Remote Element Table
Upload and save
1. Select window Subnetwork Configuration Wizard from menu Tools.
2. Select equipment Local from Actual Configuration Area and then press Retrieve. In New configu-ration area is shown the list of remote equipment included the local.
3. Press Save to file. The system will show window Save remote element configuration file.
4. Save the file with Rel extension and then press Save to finish.
Download
1. Select Subnetwork Configuration Wizard from menu Tool.
2. Press Read from file and then select the desired file (with Rel extension).
3. Press Open push button and then the system will show the file content into the New ConfigurationArea.
4. Select into the Actual configuration area the equipment you desire to download, the list of the re-mote element included the local.
5. Press Send to send the list.
AL - MN.00142.E - 009 169
26 BACK UP FULL EQUIPMENT CONFIGURATION WITHOUT POSSIBILITY OF MODIFYING THE PA-RAMETERS
26.1 SCOPE
This chapter describes the procedure to back up the full equipment configuration.
This allows to recover the original equipment configuration in case of faulty IDU replacement with spare.
26.2 CONFIGURATION UPLOAD
Foreword: it is advisable to upload the configuration during the first installation. Proceed as follows:
1. Select Equipment Configuration Wizard from menu Tools; Equipment Configuration Wizard win-dow will be displayed.
2. Select Upload and then Backup Full Equipment Configuration; Template Selection window willbe displayed.
3. Select the correct equipment template (in case of uncorrected choice the backup will be aborted).
4. Press OK and then select the equipment to be uploaded from Upload Configuration File window.
5. Press OK and then edit the file name from Save backup as window.
6. Press Save; Equipment Configuration Wizard: Complete Backup window will appear.
The window shows dynamically the backup procedure. If everything is OK, at the end of the uploadwill appear the word done showing the procedure success.
7. Press OK to finish.
26.3 CONFIGURATION DOWNLOAD
Once the spare IDU has been installed proceed as follows:
1. Select Equipment Configuration Wizard from menu Tools. Equipment Configuration Wizard win-dow will be displayed.
2. Select Download and than Restore Full Equipment Configuration from Equipment Configura-tion Wizard. Select Backup File window will be displayed.
3. Select the wanted backup file with extension .bku and then press Open. Download ConfigurationFile window will be displayed.
4. Select the equipment to download and then press OK; Equipment Configuration Wizard: Completerestore window will be displayed. This window shows dynamically the download operation. The worddone indicates that download has been successfully.
5. Press OK to finish.
Warning: In case of EOC alarm proceed to restart the equipment.
170 AL - MN.00142.E - 009
AL - MN.00142.E - 009 171
Section 6.PROGRAMMING AND SUPERVI-SION
27 PROGRAMMING AND SUPERVISION
27.1 GENERAL
The radio equipment was designed to be easily programmed and supervised.
The following tools are implemented to the purpose:
• SCT Subnetwork Craft Terminal + LCT Local Craft Terminal. They are used for remote and local con-trol of a subnetwork consisted of a maximum of 100 ALC radio equipment.
• NMS5–UX Network Management. It is used for the remote control of an entire network consisted ofdifferent SIAE equipment including ALC family radio equipment.
For details refer to relevant documentation. SCT/LCT documentation is available as help on–line.
172 AL - MN.00142.E - 009
AL - MN.00142.E - 009 173
Section 7.COMPOSITION
28 COMPOSITION OF THE INDOOR UNIT
28.1 GENERAL
The IDU is offered in the following versions:
• ALC IDU
• ALC plus IDU.
28.2 ALC IDU PART NUMBER
The IDU is available in different versions, each of one identified by a specific part number. This P/N is shownon a label attached on the IDU mechanical structure, top left side.
174 AL - MN.00142.E - 009
The P/N consists of seven digits with the following meaning:
Tab.34 - P/N meaning
This part number together with unit serial number is printed on a label, SIAE or custom, positioned on unitcover.
28.3 ALC PLUS IDU PART NUMBER
IDU Plus Compact is available in different versions; each of them is identified by a Part Number code. ThisP/N is shown on a label attached to the IDU mechanical structure, on the left top.
P/N code is composed by seven digits with the following meaning:
Tab.35 - P/N meaning
The P/N and serial number of the unit is printed on the label placed on the unit coverplate.
Digit Letter/number Meaning
1 GFunctional assembly of units completed by a mechanical struc-ture
2 A AL family
3 I Indoor installation
4 to 7
006900730076007800790080008100840085008600870088008900900091
16x2 - 75 Ohm - 1+116x2 - 75 Ohm - 1+1EOW16x2 - 75 Ohm - 1+016x2 - coax - 1+08x2 - 75 - 1+08x2 - 120 - 1+08x2 - 120 - 1+116x2 - 120 - 1+18x2 - 75 - 1+116x2 - 120 - 1+08x2 - 120 - 1+0 EOW8x2 - 120 - 1+1 EOW4x2 - 120 - 1+0 V284x2 - 120 - 1+1 V2816x2 - CX - 1+1 Eth
Digit Letter/number Meaning
1 GFunctional assembly of units completed by a mechanical struc-ture
2 A AL family
3 I Indoor installation
4 to 7
011801190120012101270128
16E1 1+016E1 1+132E1 1+032E1 1+132E1 1+0 + 3 Ethernet32E1 1+1 + 3 Ethernet
AL - MN.00142.E - 009 175
29 COMPOSITION OF OUTDOOR UNIT
29.1 GENERAL
Two ODUs are available: AL ODU and AS ODU.
29.2 AL ODU
The AL ODU consists of a mechanical structure that houses all the transceiver circuitry. In 1+1 version theconnection to the antenna is performed through a passive hybrid. Both transceiver and hybrid are offeredin different versions depending on the operating bands, the antenna configuration etc...
A label attached on the ODU structure shows the most significant parameters as:
• operating band
• operating sub–band and sideband
• part number
• serial number
• duplexer frequency
A further label is positioned on the hybrid body and shows the number of each transceiver and type ofhybrid, balanced or unbalanced.
29.3 AS ODU
The ODU AS consists of mechanical structure formed by two shells. One shell houses the transceiver mod-ule, the other houses the branching module.
Both the transceiver and the branching are available in different versions depending on the operating band,the antenna configuration, the channel filters etc.....
To the purpose on the branching mechanical structure is available a label showing the ODU most significantparameters and the P/N of the whole unit.
176 AL - MN.00142.E - 009
AL - MN.00142.E - 009 177
Section 8.LISTS AND ASSISTANCE SERVICE
30 LIST OF FIGURES
Fig.1 - Components electrostatic charge sensitive .............................................................. 10
Fig.2 - Elasticised band .................................................................................................. 10
Fig.3 - Coiled cord ........................................................................................................ 10
Fig.4 - Laser diodes ....................................................................................................... 10
Fig.5 - 1+1 ODU typical configuration with integrated antenna ............................................ 17
Fig.6 - 1+1 IDU typical configuration ............................................................................ 18
Fig.7 - 1+1 equipment block diagram............................................................................... 19
Fig.8 - 1+0 non expandable equipment block diagram........................................................ 20
Fig.9 - IDU ALC 1+0 (2/4/8xE1)...................................................................................... 25
Fig.10 - IDU ALC 1+1 (2/4/8/16xE1) ............................................................................... 25
Fig.11 - IDU ALC 1+1 (up to 16xE1 coax. conn.) + Ethernet ............................................... 25
Fig.12 - IDU ALC plus 1+1 (2/4/5/8/10/16/20/32xE1) ....................................................... 25
Fig.13 - IDU ALC plus 1+1 (2/4/5/8/10/16/20/32xE1) + Ethernet ....................................... 25
Fig.14 - IDU 1+1 (up to 16x2 Mbit/s coax. conn.) + Ethernet module................................... 26
Fig.15 - 1+1 ODU with separated antenna ........................................................................ 26
Fig.16 - 1+0 ODU with integral antenna (pole mounting).................................................... 27
Fig.17 - 1+1 ODU with integral antenna (pole mounting).................................................... 27
Fig.18 - 1+1 ODU with separated antenna (wall mounting) ................................................. 28
Fig.19 - Line interface block diagram – Tx side .................................................................. 37
Fig.20 - 2x2 Mbit/s multiplexing/demultiplexing................................................................. 38
Fig.21 - 4x2 Mbit/s multiplexing/demultiplexing................................................................. 38
Fig.22 - 8x2 Mbit/s multiplexing/demultiplexing................................................................. 39
178 AL - MN.00142.E - 009
Fig.23 - 16x2 Mbit/s multiplexing/demultiplexing............................................................... 40
Fig.24 - Line interface block diagram (Rx side) .................................................................. 41
Fig.25 - Radio interface block diagram ............................................................................. 42
Fig.26 - Main and peripheral controller connection ............................................................. 43
Fig.27 - IP/IPoverOSI protocol stack ................................................................................ 43
Fig.28 - IDU loopback .................................................................................................... 44
Fig.29 - LIM Ethernet 2 Mbit/s block diagram .................................................................... 51
Fig.30 - Tag control into field .......................................................................................... 52
Fig.31 - Output queues .................................................................................................. 52
Fig.32 - ToS/DSCP tag position into IP packets.................................................................. 53
Fig.33 - ToS/DSCP......................................................................................................... 53
Fig.34 - 1+0 ODU version............................................................................................... 59
Fig.35 - 1+1 hot stand–by version................................................................................... 59
Fig.36 - ODU block diagram............................................................................................ 60
Fig.37 - 1+1 hot stand–by 1 antenna............................................................................... 61
Fig.38 - 1+1 hot stand–by 2 antennas ............................................................................. 61
Fig.39 - ATPC operation ................................................................................................. 62
Fig.40 - DC/DC converter front coverplate ........................................................................ 63
Fig.41 - 24/48 V DC/DC converter connections to IDU 1+0 ................................................. 65
Fig.42 - 24/48 V DC/DC converter connections to IDU 1+1 ................................................. 66
Fig.43 - Grounding connections ....................................................................................... 69
Fig.44 - IDU ALC 1+1 (2x2/4x2/8x2/16x2 Mbit/s) ............................................................. 70
Fig.45 - ALC plus 32E1 (1+1).......................................................................................... 74
Fig.46 - ALC plus 32E1 + Ethernet (1+1).......................................................................... 74
Fig.47 - Pin-out Tributary IN/OUT 50 SCSI........................................................................ 75
Fig.48 - Antisliding strip ................................................................................................. 83
Fig.49 - 60–114 mm pole supporting plate fixing ............................................................... 84
Fig.50 - Adapting kit for 219 mm pole .............................................................................. 85
Fig.51 - Mounting possible position .................................................................................. 86
Fig.52 - Possible position of the fast locking mechanism ..................................................... 87
Fig.53 - Band–it pole mounting ....................................................................................... 88
Fig.54 - Supporting plate................................................................................................ 89
Fig.55 - Position of the ODU body depending on the polarisation for 1+0. For 1+1 the polarisation is always vertical: handle at the left side. .......................................................................... 90
Fig.56 - ODU body reference tooth .................................................................................. 91
Fig.57 - Final ODU assembly of 1+1 version...................................................................... 92
Fig.58 - ODU grounding ................................................................................................. 93
Fig.59 - Wall supporting plate ......................................................................................... 97
Fig.60 - Support with ODU fast locking mechanism ............................................................ 98
Fig.61 - Mounting possible positions................................................................................. 99
Fig.62 - Hybride with ODU fast locking ........................................................................... 100
Fig.63 - Position of the ODU body depending on the polarisation for 1+0. For 1+1 the polarisation is always vertical: handle at the left side. ........................................................................ 101
Fig.64 - ODU body reference tooth ................................................................................ 102
AL - MN.00142.E - 009 179
Fig.65 - Final ODU assembly of 1+1 version.................................................................... 103
Fig.66 - ODU grounding ............................................................................................... 104
Fig.67 - Centering ring position ..................................................................................... 109
Fig.68 - Antislide strip................................................................................................. 110
Fig.69 - Support mount on pole..................................................................................... 111
Fig.70 - Supporting plate position.................................................................................. 112
Fig.71 - E hole ............................................................................................................ 112
Fig.72 - Antenna installation on pole support................................................................... 113
Fig.73 - Position of the ODU handle depending on the polarisation for 1+0. For 1+1 the polarisation is always horizontal. Handle at the right side. Vertical Horizontal ........................................................................................................ 113
Fig.74 - Support system for ODU housing and reference tooth in evidence .......................... 114
Fig.75 - ODU body reference tooth ................................................................................ 115
Fig.76 - ODU housing final position for vertical polarization ............................................... 116
Fig.77 - ODU housing final position for horizontal polarization............................................ 117
Fig.78 - Hybrid and twist disk ....................................................................................... 118
Fig.79 - Hybrid mount on pole support ........................................................................... 119
Fig.80 - ODU housing final position for 1+1 version ......................................................... 120
Fig.81 - Vertical and horizontal adjustments ................................................................... 121
Fig.82 - Antenna aiming block....................................................................................... 122
Fig.83 - ODU grounding ............................................................................................... 123
Fig.84 - 1+0 pole mounting .......................................................................................... 129
Fig.85 - ODU body reference tooth ................................................................................ 130
Fig.86 - Position of the ODU handle depending on the polarisation for 1+0. For 1+1 the polarisation is always horizontal. Handle at the right side. ................................ 131
Fig.87 - 1+0 support ................................................................................................... 131
Fig.88 - ODU housing final position for both polarization ................................................... 132
Fig.89 - Antenna aiming............................................................................................... 133
Fig.90 - ODU grounding ............................................................................................... 133
Fig.91 - Hybrid and twist disk ....................................................................................... 134
Fig.92 - Hybrid installation............................................................................................ 135
Fig.93 - 1+1 ODUs installation ...................................................................................... 135
Fig.94 - Pole installation of the support .......................................................................... 138
Fig.95 - Installation of the hybrid on the pole support (only for 1+1 version)....................... 139
Fig.96 - Installation of the ODU on the support................................................................ 140
Fig.97 - ODU grounding and connection of the cables to hybrid and antenna ....................... 141
Fig.98 - Detected voltage versus Rf received signal.......................................................... 145
Fig.99 - Local Lan–1 port to remote Lan–1 port connection ............................................... 146
Fig.100 - Selection of Ethernet Throughput ..................................................................... 147
Fig.101 - Switch general settings................................................................................... 148
Fig.102 - Lan–1 interface settings.................................................................................. 148
Fig.103 - Vlan settings for Lan–1................................................................................... 149
Fig.104 - Priority setting for Lan–1 and Internal Port ........................................................ 149
Fig.105 - Vlan settings for Internal Port.......................................................................... 150
180 AL - MN.00142.E - 009
Fig.106 - Vlan Configuration Table ................................................................................. 150
Fig.107 - Virtual Lan input and output settings at Lan–1 port ............................................ 151
Fig.108 - Vlan Configuration Table with some Vlans ......................................................... 152
Fig.109 - Add a new Vlan ID to Vlan Configuration Table with output tagged ....................... 153
Fig.110 - Layer 2 and Layer 3 priority management ......................................................... 153
Fig.111 - 3 to 1 port connections................................................................................... 154
Fig.112 - Input and output setting for VLANs at Lan–1 port............................................... 155
Fig.113 - Output port properties for VLAN 3301............................................................... 155
Fig.114 - Typology 3 to 1, Virtual Lan Configuration......................................................... 156
Fig.115 - Output Queue selection on the basis of TOS/DSCP priority................................... 156
Fig.116 - Output properties of VLAN 701 ........................................................................ 157
Fig.117 - Typology 3 to 1, Virtual Lan Configuration Table with Vlan................................... 158
Fig.118 - Queue selection............................................................................................. 159
Fig.119 - Management of tagged frames according with their priority tag............................ 160
Fig.120 - Incoming packets at Lan–1 will exit to other ports unchanged according their incoming status. ........................................................................................................................ 161
Fig.121 - IDU front ...................................................................................................... 165
AL - MN.00142.E - 009 181
31 LIST OF TABLES
Tab.1 - Procedure for mouth to mouth resuscitation method ................................................ 9
Tab.2 Signal capacity......................................................................................................22
Tab.3 - Modulation and channel spacing ............................................................................22
Tab.4 - Nominal output power 1 dB tolerance - (1+0 version) ODU AL/ODU AS ......................23
Tab.5 - Guaranteed received threshold in 1+0 configuration (dBm).......................................23
Tab.6 - Guaranteed received threshold in 1+0 configuration (dBm).......................................23
Tab.7 - Power consumption (ODU AL/ODU AS) ...................................................................24
Tab.8 - Power supply connector consumption .....................................................................24
Tab.9 - IDU/ODU dimensions ...........................................................................................24
Tab.10 - IDU/ODU weight................................................................................................24
Tab.11 - Nominal output power ± 1 dB tolerance................................................................55
Tab.12 - Transmit alarm priority ......................................................................................58
Tab.13 - Characteristics of the cables ...............................................................................68
Tab.14 - Tributary connector pin–out (male 25 pin SUB–D)..................................................71
Tab.15 - 100BaseT connector pin–out for 10/100BaseT Ethernet connection ..........................72
Tab.16 - Connector pin–out for 64 kbit/s channel – V.11 interface ........................................72
Tab.17 - Connector pin–out – V.28 interface .....................................................................72
Tab.18 - Connector pin–out – RS232 PPP interface ............................................................73
Tab.19 - User in/out connector pin–out ............................................................................73
Tab.20 - Tributary IN/OUT - 75 Ohm ................................................................................75
Tab.21 - Tributary IN/OUT - 120 Ohm...............................................................................76
Tab.22 - Q3/1 and Q3/2 100BaseT connector pin-out for 10/100BaseT Ethernet connection .....77
Tab.23 - Connector pin-out RS232 PPP interface.................................................................77
Tab.24 - CH1 connector pin-out for 9600 bit/s synchronous V.24 interface.............................78
Tab.25 - CH1 connector pin-out for 9600 bit/s asynchronous V.24 interface ...........................78
Tab.26 - CH2 connector pin-out for 64 kbit/s channel - V.11 interface ...................................78
Tab.27 - User IN/OUT connector pin-out............................................................................79
Tab.28 - Tightening torque ..............................................................................................81
Tab.29 - Tightening torque ..............................................................................................82
Tab.30 - Tightening torque .............................................................................................95
Tab.31 - Tightening torque ..............................................................................................95
Tab.32 .......................................................................................................................107
Tab.33 .......................................................................................................................127
Tab.34 - P/N meaning ..................................................................................................174
Tab.35 - P/N meaning ..................................................................................................174
182 AL - MN.00142.E - 009
AL - MN.00142.E - 009 183
32 ASSISTANCE SERVICE
The assistance service provided by Siae Microelettronica will be in compliance, if stipulated, to what spe-cified in the Agreement of Software Maintenance.
To exploit this service, fill in all its parts the Module for the notification of bad SW operation(RQ.00961) and send it to the following address:
SIAE Microelettronica S.p.Avia Michelangelo Buonarroti, 2120093 Cologno MonzeseMilano - Italywww.siaemic.it
Fax + (39) 02 25391585e-mail [email protected]
32.1 RQ.00961 MODULE
Each RQ916 module can contain at most one signalling.
The information required for the signalling of the bad operation.
Warning. The compiling of the parts General Information (Siae only), Trouble notified by, Reserved to SiaeDepartment and Validation manager are at charge of the Siae personnel.
Section – Trouble Identification
- SIAE product name. Identifier or SIAE code of the product whose bad operation has been detected.
- Version. Version of the sw product whose bad operation has been detected
- Documentation Type. Identifier of the document where the problem has been detected.
- Revision. Revision of the document where the problem has been detected.
- Volume N. Number of the volume of the document where the problem has been detected.
- Page N. Number of the page, into the volume, where the problem has been detected.
- Typology. Severity of the detected bad operation:
- Critical, if it prevents the use of a main functionality of the product;
- Important, if it prevents the use of a secondary functionality of the product;
- Disturbing, if occasionally and in difficultly reproducible conditions, it prevents the use of a mainfunctionality of the product;
- Minor, if very seldom it prevents the use of a secondary functionality without important conse-quences;
- Suggestion, if no functionality of the product is damaged but some aspects (e.g.: user interface)can be improved.
- Recurrent. Possibility (Yes) or not (No) to cause the bad operation after the same sequence of inputsgiven to the product.
- Repeatable. Possibility (Yes) or not (No) to reproduce the detected bad operation.
- Annexes. Possibility (Yes) or not (No) of annexed to the NM and their possible number.
184 AL - MN.00142.E - 009
- Title. Title of the bad operation.
- Description. Clear and concise description of the bad operation, comprehensive of the edge condi-tions and, when possible and applicable, of the reference to the test (identifier and version of thetechnical documentation, test identifier).
GENERAL INFORMATION (SIAE ONLY)
Object Software Documentation Hardware Number
Submitted Distribution List: Quality Assurance
TROUBLE NOTIFIED BY
Siae Operator Name _______________________________ Date _______________________________
Customer Report Ref. _______________________________ Date _______________________________
Customer Name Reference _______________________________ Tel _______________________________
Company/Dept. _______________________________ e-mail _______________________________
Contract N Address
TROUBLE IDENTIFICATION
SW/FW failures
SIAE product name ___________________________________________________ Version ______
Documentation
Documentation type ___________________________________________________ Revision ______
Volume N. ___________________________________________________
Page N.
Typology Critical Important Disturbing Minor Suggestion
Recurrent Yes No
Repeatable Yes No
Annexes Yes: N° No
Title:Description (including enviranmental conditions):
RESERVED TO SIAE DEPARTMENT
Trouble Accepted_Open
Rejected Reasons
Notes
Analysis performed by Date Expected Closing Date
CORRECTIVE ACTION DESCRIPTION
FIXED Executed by Date Approved by
VALIDATION MANAGER
MN Closed Open
Verified by Date
Notes
Quality Record Module TROUBLE REPORT Issued byTerzo L.
Approved byGaviraghi S.
Date24/09/02
Page1/1
Siae Microelettronica all rights reserved.
Document Ref.RQ.00961
Rev/Ver003