alice o² project | alice o2 project - o-side path: tpc (c-side) … · 2020. 5. 5. · v p f-a f-c...

29
CPV CTP TOF-A TOF-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13 X11 TRD X10 TRD (10x144) X09 HMPID (14 DDL2) X08 PHOS (16 DDL2) CPV (1x24) CTP (3X48 1x48) X07 MCH-O (6x144) MID-O (2x48) X06 MCH-I (6x144) MID-O (2x48) X05 Cooling system X04 Power Haze Mayer X03 X02 X01 TPC-Calib (1x24) EmCal (24 DDL2) Y13 TPC C-side (8x144) Y12 TPC C-side (9x144) Y11 TPC C-side (9x144) Y10 TPC C-side (8x144) Y09 TPC C-side (9x144) Y08 TPC C-side (9x144) Y07 TPC A-side (8x144) Y06 TPC A-side (9x144) Y05 TPC A-side (9x144) Y04 TPC A-side (8x144) Y03 TPC A-side (9x144) Y02 TPC A-side (9x144) Y01 Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01 12700mm 6542mm CR1's layout for Run 3 New Fibers Installation Plan (Visio Project 28/02/2020) I-side path: TPC (A -side) 52x144 TOF (A-side) 1x48 TRD 10x144 CTP 3x48 CTP GPON 1x48 MCH (I-side) 6x144 MID (I-side) 2x48 FIT 3x48 CTP TRD MFT FIT ITS ZDC 2x48: From CR4 ZDC O-side path: TPC (C-side) 52x144 ITS 8x144 MFT 4x144 TOF (C-side) 3x48 TOF (A-side) 2x48 MCH O-side 6x144 MID O-side 2x48 CPV L3-I-side 1x24 1,2 m x 0,8 m MID-I MCH-O MCH-I 1,2 m x 0,8 m TOF A (3x48) C (3x48) FIT (2x48) ZDC (2x48) MFT (4x144) X12 MID-O TPC-C CTP GPON TOF-A TPC-A TPC-C MID, MCH, FIT CTP-GPON CTP-DAQ TOF-C, TOF-A-I TRD TPC-A TPC-Calib 1x24: From CR4 TPC-Calib

Upload: others

Post on 20-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

CPV

CTP

TOF-

A

TOF-

C

1,2 m x 0,8 m

ITS(4x144)

X14

Y14

DCal(16 DDL2)

Z15

ITS(4x144)

ACO(1 DDL2)

X13

X11TRD

X10

TRD

(10x144)

X09

HMPID

(14 DDL2)

X08

PHOS(16 DDL2)

CPV(1x24)

CTP (3X481x48) X07

MCH-O(6x144) MID-O (2x48)

X06

MCH-I(6x144) MID-O (2x48)

X05

Cooling system

X04

Power Haze

Mayer

X03

X02 X01

TPC-Calib(1x24)EmCal

(24 DDL2)

Y13

TPCC-side

(8x144)

Y12

TPCC-side

(9x144)

Y11

TPCC-side

(9x144)

Y10

TPCC-side

(8x144)

Y09

TPCC-side

(9x144)

Y08

TPCC-side

(9x144)

Y07

TPCA-side

(8x144)

Y06

TPCA-side

(9x144)

Y05

TPCA-side

(9x144)

Y04

TPCA-side

(8x144)

Y03

TPCA-side

(9x144)

Y02

TPCA-side

(9x144)

Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

12700mm

6542

mm

CR1's layout for Run 3New Fibers Installation Plan(Visio Project 28/02/2020)

I-side path: TPC (A -side) 52x144

TOF (A-side) 1x48

TRD 10x144 CTP 3x48

CTP GPON 1x48MCH (I-side) 6x144

MID (I-side) 2x48FIT 3x48

CTP

TRDMFT

FIT

ITS

ZDC 2x48:From CR4

ZDC

O-side path: TPC (C-side) 52x144 ITS 8x144 MFT 4x144 TOF (C-side) 3x48

TOF (A-side) 2x48 MCH O-side 6x144

MID O-side 2x48CPV L3-I-side 1x24

1,2 m x 0,8 m

MID

-I

MCH-O

MCH-I

1,2 m x 0,8 m

TOFA (3x48)C (3x48)

FIT (2x48) ZDC (2x48)

MFT (4x144)

X12

MID-O

TPC-C

CTP

GPO

N

TOF-

A

TPC-A

TPC-C

MID

, MCH

, FIT

CTP

-GPO

NCT

P-D

AQ

TO

F-C

, TO

F-A

-ITR

DTP

C-A

TPC-Calib 1x24:From CR4

TPC-Calib

Page 2: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

A B

C D A

A B

C D B

1DAQC1YX07

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

1ITSU2YA103

1ITSU2YA102

A B

C D

00

00

01

01

02

02A

1MFTU2YC118A/B

MFTC118AC118B

GPO

N

GB

Tx IT

S-I

GB

Tx M

FT

GB

Tx IT

S-O

OM

3 D

AQ

CR1 C-side Bunker Mini-Frame and Absorber

SM GBTx

SM GPON

/48

Fib

ers

OM

3 -

4xM

PO

/48

Fib

ers

OM

3 -

4xM

PO

/48

Fib

ers

SM -

4xM

PO

/ 24 Fibers SM

/ 24 Fibers SM

/ 24 Fibers SM

UX2(C24)/UX2(A100)/A

UX2(C24)/UX2(A101)/A

UX2(C24)/UX2(C118B)/A

UX

2(C

24)/

CR1

(X07

)/D

UX

2(C

24)/

CR1

(X07

)/B

UX

2(C

24)/

CR1

(X0

7)/

A

1 2 3 4

00

04

00

04

0002

Terminal plate OM33U 12xMPO-MPO

Terminal module SM3U 2xMPO-24LC/APC

Terminal module OM23U 12xE2000 (spliced)

MPO OM3 plug terminatedMPO OM3 plug not terminatedMPO-LC/APC plug terminated

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Terminal plate OM33U 12xMPO-MPO

Terminal plate SM3U 12xMPO-MPO

Terminal module SM3U 24xLC/APC (spliced)

MPO OM3 plug terminated

MPO plug not terminatedMPO SM plug terminated

Terminal plate OM33U 6xMPO-MPO

Blind plate 3U

Terminal module SM1U 24xLC/APC (spliced)

Terminal plate OM33U 12xMPO-MPO

Terminal plate OM33U 12xMPO-MPO (Spare)

MPO OM3 plug terminated

E2000 OM2 plug spliced

Blind plate 3U

Detectors: CTP, GPON ITS, MFT (Direct Trigger)

Fiber cables:3 trunk cables OM3 MPO-MPO (48F)1 trunk cable SM MPO-MPO (48F) GPON

Path: I-side from Bunker (C-side)---------------------------------------------------------------------------Fiber cables:

3 micro-duct cables SM (24F) GBTx

Path: Inside L3 from Bunker (C-side)

Giuseppe Simonetti

UX2(C24)/CR1(X07)/A: s.n. D-96616 82UX2(C24)/CR1(X07)/B: s.n. D-96617 83UX2(C24)/CR1(X07)/C: s.n. D-96618 84UX2(C24)/CR1(X07)/D: s.n. D-96619 85

UX2(C24)/UX2(A100)/A: s.n. GBTx-ITS-A-I __UX2(C24)/UX2(A101)/A: s.n. GBTx-ITS-A-O __UX2(C24)/UX2(C118B)/A: s.n. GBTx-MFT-C __

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

08

07

06

05

04

03

02

01

08

07

06

05

04

03

02

01

08

/48

Fib

ers

OM

3 -

4xM

POU

X2

(C24

)/CR

1(X

07)/

C

145 m

|------ PHOS -------|CPV-OM2|CPV|CTP|-GPON-|

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

08

D-96616 cord 2D-96616 cord 1D-96616 cord 4D-96616 cord 3

1 23 45 67 8

9 1011 12

D-96617 cord 2D-96617 cord 1D-96617 cord 4D-96617 cord 3

D-96618 cord 2D-96618 cord 1D-96618 cord 4D-96618 cord 3

CR1-X07Slot 09

1

1 1

1TRIU2YC24

D-96616 cord 2D-96616 cord 1D-96616 cord 4D-96616 cord 3

1 23 45 67 8

9 1011 12

D-96617 cord 2D-96617 cord 1D-96617 cord 4D-96617 cord 3

D-96618 cord 2D-96618 cord 1D-96618 cord 4D-96618 cord 3

UX2-C24Slot 10

1 4

L3

Bunker

C118B

C24

A100 A101

Direct Trigger

ITS-I ITS-O

MFT

Mini-Frame

Absorber

LC/APC plug spliced

00

00

01

01

02

02 ITS-O

00 01 02 03 04 05 06 07 08 09 10 11

00

00

01

01

02

02

ITS-I

00 01 02 03 04 05 06 07 08 09 10 11

Page 3: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

CPV

1CPVU2YI100

00 01 02 03 04 05 06 07 08 09 10 11

GB

Tx C

PV

C-side Bunker L3 platform

MM OM3 GBTx

/ 12 Fibers OM3

UX2(C26)/UX2(I100)/A

LC/PC plug spliced

Blind plate 3U

Terminal module OM23U 12xE2000 (spliced)

LC/PC plug spliced

E2000 OM2 plug spliced

Blind plate 3U

Detector: CPV (Direct Trigger)

Fiber cables:1 micro-duct cable OM3 (12F) GBTx

Path: Inside L3 from Bunker (C-side)

Giuseppe SimonettiUX2(C26)/UX2(I100)/A: s.n. GBTx-CPV-I __

Terminal module OM33U 12xLC/PC (spliced)

Terminal module OM33U 12xLC/PC (spliced)

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

1TRIU2YC26

00 01 02 03 04 05 06 07 08 09 10 11

00

L3

Bun

ker

I100

C26

Direct Trigger

Platform

Terminal module OM33U 2xMPO-24xLC/PC

Page 4: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

CPV

1CPVU2YI100

00 01 02 03 04 05 06 07 08 09 10 11

CR1 L3 platform

MM OM3 GBTx

/ 24 Fibers OM3

UX2(I100)/CR1(X07)/A

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Terminal module OM23U 12xE2000 (spliced)

LC/PC plug spliced

E2000 OM2 plug spliced

Blind plate 3U

Detector: CPV

Fiber cables:1 trunk cable OM3 MPO-MPO (24F)

Path: O-side from L3 (I-side platform)

Giuseppe SimonettiUX2(I100)/CR1(X07)/A: s.n. D-102823 105

Terminal module MM3U 12xLC/PC (spliced)

1DAQC1YX07

00 01 02 03 04 05 06 07 08 09 10 11

00

04

08

|------ PHOS -------|CPV-OM2|CPV|CTP|-GPON-|00

Terminal plate OM33U 12xMPO-MPO

Terminal module SM3U 2xMPO-24xLC/APC

Terminal module OM23U 12xE2000 (spliced)

MPO OM3 plug terminatedMPO OM3 plug not terminatedMPO-LC/APC plug terminated

Terminal plate OM33U 6xMPO-MPO

E2000 OM2 plug spliced

Terminal module OM33U 2xMPO-24xLC/PC

Page 5: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

00 01 02 03 04 05 06 07 08 09 10 11

52

51

50

49

48

47

46

45

44

43

42

41

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

40

39

38

37

1ITSU2YA103

A B

C D

00

00

01

01

02

02AITS-I

Mini-Frame1DAQC1YX14

CR1

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Terminal plate OM33U 2xMPO-24xLC/PC

/ 144 Fibers OM3UX2(A19)/CR1(X14)/A

/ 144 Fibers OM3UX2(A19)/CR1(X14)/B

/ 144 Fibers OM3

UX2(A19)/CR1(X14)/C

/ 144 Fibers OM3UX2(A19)/CR1(X14)/D

Detector: ITS-A-I-side, BCM

Fiber cables:4 trunk cables OM3 MPO-MPO (144F)1 conventional cable OM3 ST-ST (12F)

Path: O-side from Mini-Frame (A-side)

Giuseppe Simonetti

Terminal module SM1U 24xLC/APC (spliced)

Terminal plate OM31U 12xMPO-MPO

Terminal plate OM31U 12xMPO-MPO (Spare)

Blind plate 3U

95m trunks:

UX2(A19)/CR1(X14)/A: s.n. D-96589 11UX2(A19)/CR1(X14)/B: s.n. D-96590 12UX2(A19)/CR1(X14)/C: s.n. D-96591 13UX2(A19)/CR1(X14)/D: s.n. D-96592 14

BCM conventional cable:

UX2(A19)/CR4(X10)/A: s.n. __

MPO OM3 plug terminated

LC/APC plug spliced

00 01 02 03 04 05 06 07 08 09 10 11

Terminal plate OM33U 2xMPO-24xLC/PC (Spare)

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

1ITSU2YA19

00

/ 144 Fibers OM3UX2(A103)/UX2(A19)/A

/ 144 Fibers OM3UX2(A103)/UX2(A19)/B

/ 144 Fibers OM3UX2(A103)/UX2(A19)/C

/ 144 Fibers OM3UX2(A103)/UX2(A19)/D

27m trunks:

UX2(A103)/UX2(A19)/A: s.n. D-96581 __UX2(A103)/UX2(A19)/B: s.n. D-96582 __UX2(A103)/UX2(A19)/C: s.n. D-96583 __UX2(A103)/UX2(A19)/D: s.n. D-96584 __

08

07

06

05

04

03

02

01

09

Rack A19

95 m 27 m

LC/PC plug terminated

00 01 02 03 04 05 06 07 08 09 10 11

00

00 01 02 03 04 05 06 07 08 09 10 11

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

00

Terminal module OM33U 12xST/PC (spliced)

BCM fibersCR4-X10

/12

Fib

ers

OM

3

Back

Front

Page 6: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

52

51

50

49

48

47

46

45

44

43

42

41

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

40

39

38

37

1ITSU2YA102

ITS-O

Mini-Frame1DAQC1YX13

CR1

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1Detector: ITS-A-O-side, BCM-A

Fiber cables:4 trunk cables OM3 MPO-MPO (144F)1 conventional cable OM3 ST-ST (12F)

Path: O-side from Mini-Frame (A-side)

Giuseppe Simonetti

/ 144 Fibers OM3UX2(A19)/CR1(X13)/A

/ 144 Fibers OM3UX2(A19)/CR1(X13)/B

/ 144 Fibers OM3UX2(A19)/CR1(X13)/C

/ 144 Fibers OM3UX2(A19)/CR1(X13)/D

Terminal module SM1U 24xLC/APC (spliced)

Terminal plate OM31U 12xMPO-MPO

Terminal plate OM31U 12xMPO-MPO (Spare)

Blind plate 3U

95m trunks:

UX2(A19)/CR1(X13)/A: s.n. D-96593 15UX2(A19)/CR1(X13)/B: s.n. D-96594 16UX2(A19)/CR1(X13)/C: s.n. D-96595 17UX2(A19)/CR1(X13)/D: s.n. D-96596 18

BCM conventional cable:

UX2(A19)/CR4(X10)/A: s.n. BCM-A __

MPO OM3 plug terminated

LC/APC plug spliced

1ITSU2YA19

00

/ 144 Fibers OM3UX2(A102)/UX2(A19)/A

/ 144 Fibers OM3UX2(A102)/UX2(A19)/B

/ 144 Fibers OM3UX2(A102)/UX2(A19)/C

/ 144 Fibers OM3UX2(A102)/UX2(A19)/D

27m trunks:

UX2(A102)/UX2(A19)/A: s.n. D-96585 __UX2(A102)/UX2(A19)/B: s.n. D-96586 __UX2(A102)/UX2(A19)/C: s.n. D-96587 __UX2(A102)/UX2(A19)/D: s.n. D-96588 __

Rack A19

95 m

27 m

Terminal plate OM33U 2xMPO-24xLC/PC

Terminal plate OM33U 2xMPO-24xLC/PC (Spare)

LC/PC plug terminated

00 01 02 03 04 05 06 07 08 09 10 11

00

00 01 02 03 04 05 06 07 08 09 10 11

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

00

A B

C D

00

00

01

01

02

02A08

07

06

05

04

03

02

01

09

00 01 02 03 04 05 06 07 08 09 10 11

Terminal module OM33U 12xST/PC (spliced)

BCM fibersCR4-X10

/12

Fib

ers

OM

3

Back

Front

Page 7: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TRD

Fiber cables:10 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Bunker (C-side)

Giuseppe Simonetti

UX2(C17)/CR1(X09)/A: s.n. D-96572 69UX2(C17)/CR1(X09)/B: s.n. D-96573 70UX2(C17)/CR1(X09)/C: s.n. D-96574 71UX2(C17)/CR1(X09)/D: s.n. D-96575 72UX2(C17)/CR1(X09)/E: s.n. D-96576 73UX2(C17)/CR1(X09)/F: s.n. D-96577 74UX2(C17)/CR1(X09)/G: s.n. D-96578 75UX2(C17)/CR1(X09)/H: s.n. D-96579 76UX2(C17)/CR1(X09)/I: s.n. D-96580 77UX2(C17)/CR1(X09)/J: s.n. D-99541 78

1DAQC1YX09

CR1

1TRDU2YC17

TRD

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

05

04

03

02

01

UX2(C17)/CR1(X09)/A

UX2(C17)/CR1(X09)/B

UX2(C17)/CR1(X09)/C

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3

UX2(C17)/CR1(X09)/E

UX2(C17)/CR1(X09)/G

/ 144 Fibers OM3

/ 144 Fibers OM3

UX2(C17)/CR1(X09)/I/ 144 Fibers OM3

UX2(C17)/CR1(X09)/D/ 144 Fibers OM3

UX2(C17)/CR1(X09)/F/ 144 Fibers OM3

UX2(C17)/CR1(X09)/H/ 144 Fibers OM3

UX2(C17)/CR1(X09)/J/ 144 Fibers OM3

00

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

140 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Page 8: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

UX2(C119)/CR1(X05)/A: s.n. D-96559 9UX2(C119)/CR1(X05)/B: s.n. D-96560 10UX2(C119)/CR1(X05)/C: s.n. D-96571 11UX2(C119)/CR1(X05)/D: s.n. D-96562 12UX2(C119)/CR1(X05)/E: s.n. D-96563 13UX2(C119)/CR1(X05)/F: s.n. D-96564 14

1DAQC1YX05

CR1

1MCHU2YC119

MCH-I

Detector: MCH I-side

Fiber cables:6 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Muon (C-side)

Giuseppe Simonetti

UX2(C119)/CR1(X05)/A

UX2(C119)/CR1(X05)/B

UX2(C119)/CR1(X05)/C

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3

UX2(C119)/CR1(X05)/E/ 144 Fibers OM3

UX2(C119)/CR1(X05)/D/ 144 Fibers OM3

UX2(C119)/CR1(X05)/F/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

140 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

12

11

10

09

08

06

05

04

03

02

01

00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00

Page 9: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX05

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

00

Terminal plate OM31U 12xMPO-MPO

Terminal plate OM31U 12xMPO-MPO (Spare)

Blind plate 3U

MPO OM3 plug terminated

1MIDU2YI36

UX2(I36)/CR1(X06)/A

UX2(I36)/CR1(X06)/B/ 48 Fibers OM3

/ 48 Fibers OM3

UX2(I36)/CR1(X05)/A: s.n. D-96603 15UX2(I36)/CR1(X05)/B: s.n. D-96604 16

Detector: MID I-side

Fiber cables:2 trunk cables OM3 MPO-MPO (48F)

Path: I-side from Level 4

Giuseppe Simonetti

MPO OM3 plug not terminated

MPO OM3 plug not terminated

MID-IA B

117 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

Page 10: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX06

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

UX2(C120)/CR1(X06)/A: s.n. D-96565 99UX2(C120)/CR1(X06)/B: s.n. D-96566 100UX2(C120)/CR1(X06)/C: s.n. D-96567 101UX2(C120)/CR1(X06)/D: s.n. D-96568 102UX2(C120)/CR1(X06)/E: s.n. D-96569 103UX2(C120)/CR1(X06)/F: s.n. D-96570 104

Detector: MCH O-side

Fiber cables:6 trunk cables OM3 MPO-MPO (144F)

Path: O-side from Muon (C-side)

Giuseppe Simonetti

1MCHU2YC120

MCH-O

00

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

UX2(C120)/CR1(X06)/A

UX2(C120)/CR1(X06)/B

UX2(C120)/CR1(X06)/C

/ 144 Fibers OM3

/ 144 Fibers OM3

UX2(C120)/CR1(X06)/E/ 144 Fibers OM3

UX2(C120)/CR1(X06)/D/ 144 Fibers OM3

UX2(C120)/CR1(X06)/F/ 144 Fibers OM3

/ 144 Fibers OM3

140 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

12

11

10

09

08

06

05

04

03

02

01

00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Page 11: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

Terminal plate OM31U 12xMPO-MPO

Terminal plate OM31U 12xMPO-MPO (Spare)

Blind plate 3U

MPO OM3 plug terminated

1MIDU2YO36

UX2(O36)/CR1(X06)/A: s.n. D-96601 97UX2(O36)/CR1(X06)/B: s.n. D-96602 98

Detector: MID O-side

Fiber cables:2 trunk cables OM3 MPO-MPO (48F)

Path: O-side from Level 4

Giuseppe Simonetti

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX06

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

UX2(O36)/CR1(X06)/A

UX2(O36)/CR1(X06)/B

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

05

04

03

02

01

MPO OM3 plug not terminated

MPO OM3 plug not terminated

00

MID-OA B

/ 48 Fibers OM3

/ 48 Fibers OM3

117 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

Page 12: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

A B

C D

00

00

01

01

02

02A

1MFTU2YC118A/B

MFTC118AC118B

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX12

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

00

Terminal module SM1U 24xLC/APC (spliced)

Terminal plate OM31U 12xMPO-MPO

Terminal plate OM31U 12xMPO-MPO (Spare)

Blind plate 3U

MPO OM3 plug terminated

LC/PC plug spliced

UX2(C118A)/CR1(X12)/A: s.n. D-96597 201UX2(C118A)/CR1(X12)/B: s.n. D-96598 202UX2(C118B)/CR1(X12)/C: s.n. D-96599 203UX2(C118B)/CR1(X12)/D: s.n. D-96600 204

Detector: MFT

Fiber cables:4 trunk cables OM3 MPO-MPO (144F)

Path: O-side from Back-Frame (C-side/FASS)

Giuseppe Simonetti

Terminal module OM3

3U 2xMPO-24xLC/PC

LC/PC plug terminated

/ 144 Fibers OM3UX2(C118A)/CR1(X12)/A

/ 144 Fibers OM3UX2(C118A)/CR1(X12)/B

/ 144 Fibers OM3UX2(C118B)/CR1(X12)/C

/ 144 Fibers OM3UX2(C118B)/CR1(X12)/D

114 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00

00 01 02 03 04 05 06 07 08 09 10 11

Page 13: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX12

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

00

Terminal module OM3

3U 2xMPO-24xLC/PC

00

LC/PC plug terminated

UX2(C33)/CR1(X12)/A: s.n. D-96611 79UX2(C33)/CR1(X12)/B: s.n. D-96612 80UX2(C33)/CR1(X12)/C: s.n. D-96613 81

Detector: FIT

Fiber cables:3 trunk cables OM3 MPO-MPO (48F)

Path: I-side from Bunker (C-side)

Giuseppe Simonetti

FITA B

Terminal plate OM31U 6xMPO-MPO

Terminal plate OM31U 6xMPO-MPO (Spare)

MPO OM3 plug terminated

1FITU2YC35

C

/ 48 Fibers OM3UX2(C33)/CR1(X12)/A

/ 48 Fibers OM3UX2(C33)/CR1(X12)/B

/ 48 Fibers OM3UX2(C33)/CR1(X12)/C

MPO OM3 plug not terminated

MPO OM3 plug not terminated

140 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

52

51

50

49

48

47

46

45

44

43

42

41

40

39

38

37

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Page 14: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX12

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

00

Terminal module OM3

3U 2xMPO-24xLC/PC

00

LC/PC plug terminated

MPO OM3 plug not terminated

CR4(X08)/CR1(X12)/A: s.n. D-96614 95CR4(X08)/CR1(X12)/B: s.n. D-96615 96

Detector: ZDC

Fiber cables:2 trunk cables OM3 MPO-MPO (48F)

Path: O-side from CR4

Giuseppe Simonetti

ZDCA B

Terminal plate OM31U 12xMPO-MPO

Terminal plate OM31U 12xMPO-MPO (Spare)

1ZDCC4YX08

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

05

04

03

02

01

/ 48 Fibers OM3CR4(X08)/CR1(X12)/A

/ 48 Fibers OM3CR4(X08)/CR1(X12)/B

Blind plate 3U

MPO OM3 plug terminated

MPO OM3 plug not terminated

41 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Page 15: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX12

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

Terminal module OM3

3U 2xMPO-24xLC/PC

00

LC/PC plug terminated

MPO OM3 plug not terminated

A A

B B

00

00

01

01

02

02

1TOFU2YA107A/B

TOF-A-OA107A (Baby Frame)

A107B (Door side)

TOF-A-IA A

1TOFU2YA106

Terminal module OM31U 2xMPO-24xLC/PC (Spare)

Terminal module OM31U 2xMPO-24xLC/PC

Blind plate 3U

MPO OM3 plug terminated

LC/PC plug spliced

Detector: TOF A-side

Fiber cables:2 trunk cables OM3 MPO-MPO (48F)

Path: O-side from Baby-Frame

Fiber cables:1 trunk cables OM3 MPO-MPO (48F)

Path: I-side from Baby-Frame

Giuseppe Simonetti

UX2(A106)/CR1(X12)/A: s.n. D-96605 85UX2(A107A)/CR1(X12)/A: s.n. D-96606 118UX2(A107B)/CR1(X12)/B: s.n. D-96607 119

/ 48 Fibers OM3UX2(C33)/CR1(X12)/A-I

/ 48 Fibers OM3UX2(C33)/CR1(X12)/A-O

/ 48 Fibers OM3UX2(C33)/CR1(X12)/B-O

107 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

04

08

00

00

1

1

2

2

3

3

4

4

1 2 3 4

D-96605 cord 2D-96605 cord 1

D-96605 cord 4D-96605 cord 3

1 2

3 4

5 6

7 8

9 10

11 12

D-96606 cord 2D-96606 cord 1

D-96606 cord 4D-96606 cord 3

D-96607 cord 2D-96607 cord 1

D-96607 cord 4D-96607 cord 3

Slot 00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Page 16: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YX12

CR1

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

Terminal plate OM33U 6xMPO-MPO

Terminal plate OM33U 6xMPO-MPO (Spare)

Terminal module OM3

3U 2xMPO-24xLC/PC

00

LC/PC plug terminated

MPO OM3 plug not terminated

TOF-C-I

00

6xE2000/APC SM (spliced)

6xE2000 OM2 (spliced)

12xE2000 OM2 (spliced)

1TOFU2YC117

TOF-C-O

00

1TOFU2YC108

TOF-C-O

00

1TOFU2YC110

Detector: TOF C-side

Fiber cables:3 trunk cables OM3 MPO-MPO (48F)

Path: O-side from Back-Frame (C-side/FASS)

Giuseppe Simonetti

UX2(C117)/CR1(X12)/A: s.n. D-96608 106UX2(C108)/CR1(X12)/B: s.n. D-96609 107UX2(C110)/CR1(X12)/C: s.n. D-96610 108

C100

C101

C102

C103C104

C105

C106

C107

C108

C109

C110

C111

C112C113

C114

C115

C116

C117

/ 48 Fibers OM3UX2(C117)/CR1(X12)/A

/ 48 Fibers OM3UX2(C108)/CR1(X12)/B

/ 48 Fibers OM3UX2(C110)/CR1(X12)/C

Terminal plate OM33U 12xMPO-MPO

Blind plate 3U

Terminal module OM3

3U 2xMPO-24xLC/PC

MPO OM3 plug terminated

LC/PC plug terminated

Terminal module OM3

3U 2xMPO-24xLC/PC (Spare)E2000 OM2 plug spliced

E2000/APC SM plug spliced

121 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

D-96608 cord 2D-96608 cord 1

D-96608 cord 4D-96608 cord 3

1 2

3 4

5 6

7 8

9 10

11 12

D-96609 cord 2D-96609 cord 1

D-96609 cord 4D-96609 cord 3

D-96610 cord 2D-96610 cord 1

D-96610 cord 4D-96610 cord 3

Slot 01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

1 2 3 4

00 01 02 03 04 05 06 07 08 09 10 11

1 2 3 4

00

00 01 02 03 04 05 06 07 08 09 10 11

1 2 3 4

00

04

08

00

Page 17: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

1DAQC1YY13

CR1

Blind plate 3U

00

Terminal module OM3

3U 2xMPO-24xLC/PC

LC/PC plug terminated

CR4(Y09)/CR1(Y13)/A: s.n. __

Detector: TPC Calibration

Fiber cables:1 trunk cable OM3 MPO-MPO (24F)

Path: O-side from CR4

Giuseppe Simonetti

TPC Calib

A

Terminal plate OM31U 6xMPO-MPO

1TPCC4YY09

56

55

54

53

52

51

50

49

48

47

46

45

44

43

42

41

05

04

03

02

01

/ 24 Fibers OM3CR4(Y09)/CR1(Y13)/A

Blind plate 3U

MPO OM3 plug terminated

MPO OM3 plug not terminated

45 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

E2000 OM2 plug spliced

Terminal module OM33U 12xE2000 (spliced)

CR4-Y09

00

Page 18: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

00 01 02 03 04 05 06 07 08 09 10 11

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC A-side (sec. 01, 02, 03)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Mini-Frame through rack A19 (A-side)

Giuseppe Simonetti

UX2(A19)/CR1(Y01)/A: s.n. D-96483 17UX2(A19)/CR1(Y01)/B: s.n. D-96477 18UX2(A19)/CR1(Y01)/C: s.n. D-96499 19UX2(A19)/CR1(Y01)/D: s.n. D-96501 20UX2(A19)/CR1(Y01)/E: s.n. D-96474 21UX2(A19)/CR1(Y01)/F: s.n. D-96475 22UX2(A19)/CR1(Y01)/G: s.n. D-96480 23UX2(A19)/CR1(Y01)/H: s.n. D-96503 24UX2(A19)/CR1(Y01)/I: s.n. D-96469 25

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY01

CR1

1TPCU2YA19

1TPCU2YA100

TPC

Mini-Frame (A100)

UX2(A19)/CR1(Y01)/A

UX2(A19)/CR1(Y01)/B

UX2(A100)/UX2(A19)/A: s.n. D-96437 __UX2(A100)/UX2(A19)/B: s.n. D-96405 __UX2(A100)/UX2(A19)/C: s.n. D-96412 __UX2(A100)/UX2(A19)/D: s.n. D-96411 __UX2(A100)/UX2(A19)/E: s.n. D-96410 __UX2(A100)/UX2(A19)/F: s.n. D-96454 __UX2(A100)/UX2(A19)/G: s.n. D-96420 __UX2(A100)/UX2(A19)/H: s.n. D-96407 __UX2(A100)/UX2(A19)/I: s.n. D-96436 __

Rack A19

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A19)/CR1(Y01)/C

/ 144 Fibers OM3UX2(A19)/CR1(Y01)/D

/ 144 Fibers OM3UX2(A19)/CR1(Y01)/E

/ 144 Fibers OM3UX2(A19)/CR1(Y01)/F

/ 144 Fibers OM3UX2(A19)/CR1(Y01)/G

/ 144 Fibers OM3UX2(A19)/CR1(Y01)/H

UX2(A19)/CR1(Y01)/I/ 144 Fibers OM3

52

51

41

40

39

38

37

36

35

34

33

32

31

30

05

04

03

02

01

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

UX2(A100)/UX2(A19)/A

UX2(A100)/UX2(A19)/B/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A100)/UX2(A19)/C

/ 144 Fibers OM3UX2(A100)/UX2(A19)/D

/ 144 Fibers OM3UX2(A100)/UX2(A19)/E

/ 144 Fibers OM3UX2(A100)/UX2(A19)/F

/ 144 Fibers OM3UX2(A100)/UX2(A19)/G

/ 144 Fibers OM3UX2(A100)/UX2(A19)/H

UX2(A100)/UX2(A19)/I/ 144 Fibers OM3

90 m 27 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

00 01 02 03 04 05 06 07 08 09 10 11

00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

12

11

10

08

07

06

05

04

03

02

01

09

00Back

Front

Page 19: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

00 01 02 03 04 05 06 07 08 09 10 11

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC A-side (sec. 04, 05, 06)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Mini-Frame through rack A19 (A-side)

Giuseppe Simonetti

UX2(A19)/CR1(Y02)/A: s.n. D-96505 60UX2(A19)/CR1(Y02)/B: s.n. D-96456 61UX2(A19)/CR1(Y02)/C: s.n. D-96471 62UX2(A19)/CR1(Y02)/D: s.n. D-96490 63UX2(A19)/CR1(Y02)/E: s.n. D-96497 64UX2(A19)/CR1(Y02)/F: s.n. D-96470 65UX2(A19)/CR1(Y02)/G: s.n. D-96472 66UX2(A19)/CR1(Y02)/H: s.n. D-96495 67UX2(A19)/CR1(Y02)/I: s.n. D-96491 68

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY02

CR1

1TPCU2YA19

1TPCU2YA101

TPC

Mini-Frame (A101)

UX2(A19)/CR1(Y02)/A

UX2(A19)/CR1(Y02)/B

UX2(A101)/UX2(A19)/A: s.n. D-96448 __UX2(A101)/UX2(A19)/B: s.n. D-96406 __UX2(A101)/UX2(A19)/C: s.n. D-96409 __UX2(A101)/UX2(A19)/D: s.n. D-96403 __UX2(A101)/UX2(A19)/E: s.n. D-96434 __UX2(A101)/UX2(A19)/F: s.n. D-96404 __UX2(A101)/UX2(A19)/G: s.n. D-96432 __UX2(A101)/UX2(A19)/H: s.n. D-96414 __UX2(A101)/UX2(A19)/I: s.n. D-96423 __

Rack A19

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A19)/CR1(Y02)/C

/ 144 Fibers OM3UX2(A19)/CR1(Y02)/D

/ 144 Fibers OM3UX2(A19)/CR1(Y02)/E

/ 144 Fibers OM3UX2(A19)/CR1(Y02)/F

/ 144 Fibers OM3UX2(A19)/CR1(Y02)/G

/ 144 Fibers OM3UX2(A19)/CR1(Y02)/H

UX2(A19)/CR1(Y02)/I/ 144 Fibers OM3

52

51

36

35

34

33

32

31

30

29

28

27

26

25

05

04

03

02

01

UX2(A101)/UX2(A19)/A

UX2(A101)/UX2(A19)/B/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A101)/UX2(A19)/C

/ 144 Fibers OM3UX2(A101)/UX2(A19)/D

/ 144 Fibers OM3UX2(A101)/UX2(A19)/E

/ 144 Fibers OM3UX2(A101)/UX2(A19)/F

/ 144 Fibers OM3UX2(A101)/UX2(A19)/G

/ 144 Fibers OM3UX2(A101)/UX2(A19)/H

UX2(A101)/UX2(A19)/I/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

90 m 27 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

12

11

10

08

07

06

05

04

03

02

01

09

00Back

Front

Page 20: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

00 01 02 03 04 05 06 07 08 09 10 11

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC A-side (sec. 07, 08, 09)

Fiber cables:8 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Mini-Frame through rack A19 (A-side)

Giuseppe Simonetti

UX2(A19)/CR1(Y03)/A: s.n. D-96476 52UX2(A19)/CR1(Y03)/B: s.n. D-96485 53UX2(A19)/CR1(Y03)/C: s.n. D-96494 54UX2(A19)/CR1(Y03)/D: s.n. D-96460 55UX2(A19)/CR1(Y03)/E: s.n. D-96498 56UX2(A19)/CR1(Y03)/F: s.n. D-96484 57UX2(A19)/CR1(Y03)/G: s.n. D-96487 58UX2(A19)/CR1(Y03)/H: s.n. D-96492 59

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY03

CR1

1TPCU2YA19

1TPCU2YA101

TPC

Mini-Frame (A101)

UX2(A19)/CR1(Y03)/A

UX2(A19)/CR1(Y03)/B

UX2(A101)/UX2(A19)/J: s.n. D-96444 __UX2(A101)/UX2(A19)/K: s.n. D-96419 __UX2(A101)/UX2(A19)/L: s.n. D-96440 __UX2(A101)/UX2(A19)/M: s.n. D-96441 __UX2(A101)/UX2(A19)/N: s.n. D-96408 __UX2(A101)/UX2(A19)/O: s.n.D-96430 __UX2(A101)/UX2(A19)/P: s.n. D-96449 __UX2(A101)/UX2(A19)/Q: s.n. D-96443 __

Rack A19

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A19)/CR1(Y03)/C

/ 144 Fibers OM3UX2(A19)/CR1(Y03)/D

/ 144 Fibers OM3UX2(A19)/CR1(Y03)/E

/ 144 Fibers OM3UX2(A19)/CR1(Y03)/F

/ 144 Fibers OM3UX2(A19)/CR1(Y03)/G

/ 144 Fibers OM3UX2(A19)/CR1(Y03)/H

52

51

31

30

29

28

27

26

25

24

23

22

21

20

05

04

03

02

01

UX2(A101)/UX2(A19)/J

UX2(A101)/UX2(A19)/K/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A101)/UX2(A19)/L

/ 144 Fibers OM3UX2(A101)/UX2(A19)/M

/ 144 Fibers OM3UX2(A101)/UX2(A19)/N

/ 144 Fibers OM3UX2(A101)/UX2(A19)/O

/ 144 Fibers OM3UX2(A101)/UX2(A19)/P

/ 144 Fibers OM3UX2(A101)/UX2(A19)/Q

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

90 m 27 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

00

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

12

11

10

08

07

06

05

04

03

02

01

09

00

Back

Front

Page 21: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

00 01 02 03 04 05 06 07 08 09 10 11

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC A-side (sec. 10, 11, 12)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Mini-Frame through rack A19 (A-side)

Giuseppe Simonetti

UX2(A19)/CR1(Y04)/A: s.n. D-96468 43UX2(A19)/CR1(Y04)/B: s.n. D-96493 44UX2(A19)/CR1(Y04)/C: s.n. D-96496 45UX2(A19)/CR1(Y04)/D: s.n. D-96455 46UX2(A19)/CR1(Y04)/E: s.n. D-96486 47UX2(A19)/CR1(Y04)/F: s.n. D-96467 48UX2(A19)/CR1(Y04)/G: s.n. D-96502 49UX2(A19)/CR1(Y04)/H: s.n. D-96504 50UX2(A19)/CR1(Y04)/I: s.n. D-96478 51

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY04

CR1

1TPCU2YA19

1TPCU2YA102

TPC

Mini-Frame (A102)

UX2(A19)/CR1(Y04)/A

UX2(A19)/CR1(Y04)/B

UX2(A102)/UX2(A19)/E: s.n. D-96431 __UX2(A102)/UX2(A19)/F: s.n. D-96442 __UX2(A102)/UX2(A19)/G: s.n. D-96433 __UX2(A102)/UX2(A19)/H: s.n. D-96445 __UX2(A102)/UX2(A19)/I: s.n. D-96422 __UX2(A102)/UX2(A19)/J: s.n. D-96425 __UX2(A102)/UX2(A19)/K: s.n. D-96417 __UX2(A102)/UX2(A19)/L: s.n. D-96418 __UX2(A102)/UX2(A19)/M: s.n. D-96421 __

Rack A19

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A19)/CR1(Y04)/C

/ 144 Fibers OM3UX2(A19)/CR1(Y04)/D

/ 144 Fibers OM3UX2(A19)/CR1(Y04)/E

/ 144 Fibers OM3UX2(A19)/CR1(Y04)/F

/ 144 Fibers OM3UX2(A19)/CR1(Y04)/G

/ 144 Fibers OM3UX2(A19)/CR1(Y04)/H

UX2(A19)/CR1(Y04)/I/ 144 Fibers OM3

51

50

26

25

24

23

22

21

20

19

18

17

16

15

04

03

02

01

00

UX2(A102)/UX2(A19)/E

UX2(A102)/UX2(A19)/F/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A102)/UX2(A19)/G

/ 144 Fibers OM3UX2(A102)/UX2(A19)/H

/ 144 Fibers OM3UX2(A102)/UX2(A19)/I

/ 144 Fibers OM3UX2(A102)/UX2(A19)/J

/ 144 Fibers OM3UX2(A102)/UX2(A19)/K

/ 144 Fibers OM3UX2(A102)/UX2(A19)/L

UX2(A102)/UX2(A19)/M/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

90 m 27 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

00

00 01 02 03 04 05 06 07 08 09 10 11

A B

C D

00

00

01

01

02

02A08

07

06

05

04

03

02

01

09

00 01 02 03 04 05 06 07 08 09 10 11

Back

Front

Page 22: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

00 01 02 03 04 05 06 07 08 09 10 11

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC A-side (sec. 13, 14, 15)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Mini-Frame through rack A19 (A-side)

Giuseppe Simonetti

UX2(A19)/CR1(Y05)/A: s.n. D-96465 35UX2(A19)/CR1(Y05)/B: s.n. D-96481 36UX2(A19)/CR1(Y05)/C: s.n. D-96473 37UX2(A19)/CR1(Y05)/D: s.n. D-96459 38UX2(A19)/CR1(Y05)/E: s.n. D-96466 39UX2(A19)/CR1(Y05)/F: s.n. D-96500 40UX2(A19)/CR1(Y05)/G: s.n. D-96461 41UX2(A19)/CR1(Y05)/H: s.n. D-96462 42UX2(A19)/CR1(Y06)/I: s.n. D-96458 34

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY05

CR1

1TPCU2YA19

1TPCU2YA103

TPC

Mini-Frame (A103)

UX2(A19)/CR1(Y05)/A

UX2(A19)/CR1(Y05)/B

UX2(A103)/UX2(A19)/E: s.n. D-96413 __UX2(A103)/UX2(A19)/F: s.n. D-96450 __UX2(A103)/UX2(A19)/G: s.n. D-96426 __UX2(A103)/UX2(A19)/H: s.n. D-96416 __UX2(A103)/UX2(A19)/I: s.n. D-96438 __UX2(A103)/UX2(A19)/J: s.n. D-96447 __UX2(A103)/UX2(A19)/K: s.n. D-96435 __UX2(A103)/UX2(A19)/L: s.n. D-96427 __UX2(A100)/UX2(A19)/M: s.n. D-96446 __

Rack A19

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A19)/CR1(Y05)/C

/ 144 Fibers OM3UX2(A19)/CR1(Y05)/D

/ 144 Fibers OM3UX2(A19)/CR1(Y05)/E

/ 144 Fibers OM3UX2(A19)/CR1(Y05)/F

/ 144 Fibers OM3UX2(A19)/CR1(Y05)/G

/ 144 Fibers OM3UX2(A19)/CR1(Y05)/H

51

50

21

20

19

18

17

16

15

14

13

12

11

10

04

03

02

01

00

UX2(A103)/UX2(A19)/E

UX2(A103)/UX2(A19)/F/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A103)/UX2(A19)/G

/ 144 Fibers OM3UX2(A103)/UX2(A19)/H

/ 144 Fibers OM3UX2(A103)/UX2(A19)/I

/ 144 Fibers OM3UX2(A103)/UX2(A19)/J

/ 144 Fibers OM3UX2(A103)/UX2(A19)/K

/ 144 Fibers OM3UX2(A103)/UX2(A19)/L

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

90 m 27 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00

00

00 01 02 03 04 05 06 07 08 09 10 11

A B

C D

00

00

01

01

02

02A08

07

06

05

04

03

02

01

09

00 01 02 03 04 05 06 07 08 09 10 11

UX2(A19)/CR1(Y04)/I/ 144 Fibers OM3 UX2(A102)/UX2(A19)/M

/ 144 Fibers OM3

Back

Front

Page 23: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

00 01 02 03 04 05 06 07 08 09 10 11

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC A-side (sec. 16, 17, 00)

Fiber cables:8 trunk cables OM3 MPO-MPO (144F)

Path: I-side from Mini-Frame through rack A19 (A-side)

Giuseppe Simonetti

UX2(A19)/CR1(Y06)/A: s.n. D-96506 26UX2(A19)/CR1(Y06)/B: s.n. D-96457 27UX2(A19)/CR1(Y06)/C: s.n. D-96482 28UX2(A19)/CR1(Y06)/D: s.n. D-96479 29UX2(A19)/CR1(Y06)/E: s.n. D-96488 30UX2(A19)/CR1(Y06)/F: s.n. D-96463 31UX2(A19)/CR1(Y06)/G: s.n. D-96489 32UX2(A19)/CR1(Y06)/H: s.n. D-96464 33

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY06

CR1

1TPCU2YA19

1TPCU2YA100

TPC

Mini-Frame (A100)

UX2(A19)/CR1(Y06)/A

UX2(A19)/CR1(Y06)/B

UX2(A100)/UX2(A19)/J: s.n. D-96439 __UX2(A100)/UX2(A19)/K: s.n. D-96415 __UX2(A100)/UX2(A19)/L: s.n. D-96424 __UX2(A100)/UX2(A19)/M: s.n. D-96451 __UX2(A100)/UX2(A19)/N: s.n. D-96429 __UX2(A100)/UX2(A19)/O: s.n. D-96453 __UX2(A100)/UX2(A19)/P: s.n. D-96428 __UX2(A100)/UX2(A19)/Q: s.n. D-96452 __

Rack A19

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A19)/CR1(Y06)/C

/ 144 Fibers OM3UX2(A19)/CR1(Y06)/D

/ 144 Fibers OM3UX2(A19)/CR1(Y06)/E

/ 144 Fibers OM3UX2(A19)/CR1(Y06)/F

/ 144 Fibers OM3UX2(A19)/CR1(Y06)/G

/ 144 Fibers OM3UX2(A19)/CR1(Y06)/H

UX2(A100)/UX2(A19)/J/ 144 Fibers OM3

/ 144 Fibers OM3UX2(A100)/UX2(A19)/K

/ 144 Fibers OM3UX2(A100)/UX2(A19)/L

/ 144 Fibers OM3UX2(A100)/UX2(A19)/M

/ 144 Fibers OM3UX2(A100)/UX2(A19)/N

/ 144 Fibers OM3UX2(A100)/UX2(A19)/O

/ 144 Fibers OM3UX2(A100)/UX2(A19)/P

UX2(A100)/UX2(A19)/Q/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

90 m 27 m

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

12

11

10

08

07

06

05

04

03

02

01

09

00

00

00

52

51

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

/ 1 MPO (# 12)

11 MPOs (# 1-11)

Terminal module MM3U 1MPO-12xLC/PC

TPC Calibration Control:

MPO #12 splitted in 12 LC/PC

MPO OM3 plug not terminated

Back

Front

/ 1 MPO (# 12)

11 MPOs (# 1-11)

Terminal module MM3U 1MPO-12xLC/PC

MPO OM3 plug not terminated

TPC Calibration Control

Page 24: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

C100

C101

C102

C103C104

C105

C106

C107

C108

C109

C110

C111

C112C113

C114

C115

C116

C117

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC C-side (sec. 00, 01, 02)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: O-side from FASS (C-side)

Giuseppe Simonetti

UX2(C100)/CR1(Y07)/A: s.n. D-96507 109UX2(C100)/CR1(Y07)/B: s.n. D-96508 110UX2(C100)/CR1(Y07)/C: s.n. D-96509 111UX2(C100)/CR1(Y07)/D: s.n. D-96510 112UX2(C101)/CR1(Y07)/A: s.n. D-96511 113UX2(C101)/CR1(Y07)/B: s.n. D-96512 114UX2(C101)/CR1(Y07)/C: s.n. D-96513 115UX2(C102)/CR1(Y07)/A: s.n. D-96514 116UX2(C102)/CR1(Y07)/B: s.n. D-96515 117

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY07

CR1

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - --|

|---- -- -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |

TPCC00

TPCC01

TPCC02

1TPCU2YC100

1TPCU2YC101

1TPCU2YC102

00

TOF

TTC

TOF

DCS

|------ -- - -- - -- -- - -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- - --|

TOF

TTC

TOF

DCS

TOF

TTC

TOF

DCS

UX2(C100)/CR1(Y07)/A

UX2(C100)/CR1(Y07)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C100)/CR1(Y07)/C

/ 144 Fibers OM3UX2(C100)/CR1(Y07)/D

UX2(C101)/CR1(Y07)/A

UX2(C101)/CR1(Y07)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C101)/CR1(Y07)/C

UX2(C102)/CR1(Y07)/A

UX2(C102)/CR1(Y07)/B/ 144 Fibers OM3

/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

6xE2000/APC SM (spliced)

6xE2000 OM2 (spliced)

12xE2000 OM2 (spliced)

E2000 OM2 plug spliced

E2000/APC SM plug spliced

126 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

D-96513D-96512

D-96511

D-96514

D-96507

D-96508

D-96509

D-96510

Cord loop inside subrack

Page 25: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

C100

C101

C102

C103C104

C105

C106

C107

C108

C109

C110

C111

C112C113

C114

C115

C116

C117

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC C-side (sec. 03, 04, 05)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: O-side from FASS (C-side)

Giuseppe Simonetti

UX2(C103)/CR1(Y08)/A: s.n. D-96516 205UX2(C103)/CR1(Y08)/B: s.n. D-96517 206UX2(C103)/CR1(Y08)/C: s.n. D-96518 207UX2(C104)/CR1(Y08)/A: s.n. D-96519 208UX2(C104)/CR1(Y08)/B: s.n. D-96520 209UX2(C104)/CR1(Y08)/C: s.n. D-96521 210UX2(C105)/CR1(Y08)/A: s.n. D-96522 211UX2(C105)/CR1(Y08)/B: s.n. D-96523 212UX2(C105)/CR1(Y08)/C: s.n. D-96524 213

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY08

CR1

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |Pre-Tri g|

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |

TPCC03

TPCC04

TPCC05

1TPCU2YC103

1TPCU2YC104

1TPCU2YC105

TOF

TTC

TOF

DCS

|------ -- - -- - -- -- - -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- - --|

TOF

TTC

TOF

DCS

UX2(C103)/CR1(Y08)/A

UX2(C103)/CR1(Y08)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C103)/CR1(Y08)/C

UX2(C105)/CR1(Y08)/C

UX2(C104)/CR1(Y08)/A

UX2(C104)/CR1(Y08)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C104)/CR1(Y08)/C

UX2(C105)/CR1(Y08)/A

UX2(C105)/CR1(Y08)/B/ 144 Fibers OM3

/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

6xE2000/APC SM (spliced)

6xE2000 OM2 (spliced)

12xE2000 OM2 (spliced)

E2000 OM2 plug spliced

E2000/APC SM plug spliced

/ 144 Fibers OM3

TOF

TTC

TOF

DCS

00

TRD

Pre

Tri g

E2000/APC SM plug not spliced

126 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

C103

C104

C105

D-96516D-96518

D-96519D-96521

D-96522D-96524

Cord loop inside subrack

Page 26: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

C100

C101

C102

C103C104

C105

C106

C107

C108

C109

C110

C111

C112C113

C114

C115

C116

C117

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC C-side (sec. 06, 07, 08)

Fiber cables:8 trunk cables OM3 MPO-MPO (144F)

Path: O-side from FASS (C-side)

Giuseppe Simonetti

UX2(C106)/CR1(Y09)/A: s.n. D-96525 214UX2(C106)/CR1(Y09)/B: s.n. D-96526 215UX2(C106)/CR1(Y09)/C: s.n. D-96527 216UX2(C107)/CR1(Y09)/A: s.n. D-96528 217UX2(C107)/CR1(Y09)/B: s.n. D-96529 218UX2(C107)/CR1(Y09)/C: s.n. D-96530 219UX2(C108)/CR1(Y09)/A: s.n. D-96531 220UX2(C108)/CR1(Y09)/B: s.n. D-96532 221

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY09

CR1

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - --|

|---- -- -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |

TPCC06

TPCC07

TPCC08

1TPCU2YC106

1TPCU2YC107

1TPCU2YC108

TOF

TTC

TOF

DCS

|------ -- - -- - -- -- - -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- - --|

TOF

TTC

TOF

DCS

UX2(C106)/CR1(Y09)/A

UX2(C106)/CR1(Y09)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C106)/CR1(Y09)/C

UX2(C107)/CR1(Y09)/A

UX2(C107)/CR1(Y09)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C107)/CR1(Y09)/C

UX2(C108)/CR1(Y09)/A

UX2(C108)/CR1(Y09)/B/ 144 Fibers OM3

/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

6xE2000/APC SM (spliced)

6xE2000 OM2 (spliced)

12xE2000 OM2 (spliced)

E2000 OM2 plug spliced

E2000/APC SM plug spliced

TOF

TTC

TOF

DCS

00

Terminal plate OM3

3U 2xMPO-24xLC/PC

LC/PC plug terminated

126 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

D-96609

D-96532

D-96531

D-96525D-96526

D-96527

D-96528D-96529

D-96530

Cord loop inside subrack

Page 27: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

C100

C101

C102

C103C104

C105

C106

C107

C108

C109

C110

C111

C112C113

C114

C115

C116

C117

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC C-side (sec. 09, 10, 11)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: O-side from FASS (C-side)

Giuseppe Simonetti

UX2(C109)/CR1(Y10)/A: s.n. D-96533 222UX2(C109)/CR1(Y10)/B: s.n. D-96534 223UX2(C109)/CR1(Y10)/C: s.n. D-96535 224UX2(C110)/CR1(Y10)/A: s.n. D-96536 225UX2(C110)/CR1(Y10)/B: s.n. D-96537 226UX2(C110)/CR1(Y10)/C: s.n. D-96538 227UX2(C111)/CR1(Y10)/A: s.n. D-96539 228UX2(C111)/CR1(Y10)/B: s.n. D-96540 229UX2(C111)/CR1(Y10)/C: s.n. D-96541 230

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY10

CR1

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - --|

|---- -- -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |

TPCC09

TPCC10

TPCC11

1TPCU2YC109

1TPCU2YC110

1TPCU2YC111

TOF

TTC

TOF

DCS

|------ -- - -- - -- -- - -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- - --|

UX2(C109)/CR1(Y10)/A

UX2(C109)/CR1(Y10)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C109)/CR1(Y10)/C

UX2(C111)/CR1(Y10)/C

UX2(C110)/CR1(Y10)/A

UX2(C110)/CR1(Y10)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C110)/CR1(Y10)/C

UX2(C111)/CR1(Y10)/A

UX2(C111)/CR1(Y10)/B/ 144 Fibers OM3

/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

6xE2000/APC SM (spliced)

6xE2000 OM2 (spliced)

12xE2000 OM2 (spliced)

E2000 OM2 plug spliced

E2000/APC SM plug spliced

/ 144 Fibers OM3

TOF

TTC

TOF

DCS

00

TOF

TTC

TOF

DCS

Terminal plate OM3

3U 2xMPO-24xLC/PC

LC/PC plug terminated

126 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Cord loop inside subrack

D-96533

D-96534

D-96535

D-96536

D-96537D-96538

D-96539D-96540

D-96541

D-96610

Page 28: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

C100

C101

C102

C103C104

C105

C106

C107

C108

C109

C110

C111

C112C113

C114

C115

C116

C117

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC C-side (sec. 12, 13, 14)

Fiber cables:9 trunk cables OM3 MPO-MPO (144F)

Path: O-side from FASS (C-side)

Giuseppe Simonetti

UX2(C112)/CR1(Y11)/A: s.n. D-96542 231UX2(C112)/CR1(Y11)/B: s.n. D-96543 232UX2(C112)/CR1(Y11)/C: s.n. D-96544 233UX2(C113)/CR1(Y11)/A: s.n. D-96545 234UX2(C113)/CR1(Y11)/B: s.n. D-96546 235UX2(C113)/CR1(Y11)/C: s.n. D-96547 236UX2(C114)/CR1(Y11)/A: s.n. D-96548 237UX2(C114)/CR1(Y11)/B: s.n. D-96549 238UX2(C114)/CR1(Y11)/C: s.n. D-96550 239

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY11

CR1

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |Pre-Tri g|

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |

TPCC12

TPCC13

TPCC14

1TPCU2YC112

1TPCU2YC113

1TPCU2YC114

TOF

TTC

TOF

DCS

|------ -- - -- - -- -- - -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- - --|

TOF

TTC

TOF

DCS

UX2(C112)/CR1(Y11)/A

UX2(C112)/CR1(Y11)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C112)/CR1(Y11)/C

UX2(C114)/CR1(Y11)/C

UX2(C113)/CR1(Y11)/A

UX2(C113)/CR1(Y11)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C113)/CR1(Y11)/C

UX2(C114)/CR1(Y11)/A

UX2(C114)/CR1(Y11)/B/ 144 Fibers OM3

/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

6xE2000/APC SM (spliced)

6xE2000 OM2 (spliced)

12xE2000 OM2 (spliced)

E2000 OM2 plug spliced

E2000/APC SM plug spliced

/ 144 Fibers OM3

TOF

TTC

TOF

DCS

00

TRD

Pre

Tri g

E2000/APC SM plug not spliced

126 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Cord loop inside subrack

C113

D-96542D-96543 D-96544

D-96545 D-96547

D-96548D-96550

Page 29: ALICE O² Project | ALICE O2 Project - O-side path: TPC (C-side) … · 2020. 5. 5. · V P F-A F-C 1,2 m x 0,8 m ITS (4x144) X14 Y14 DCal (16 DDL2) Z15 ITS (4x144) ACO (1 DDL2) X13

C100

C101

C102

C103C104

C105

C106

C107

C108

C109

C110

C111

C112C113

C114

C115

C116

C117

X14

Y14

Z15

X13 X12 X11 X10 X09 X08 X07 X06 X05 X04 X03 X02 X01

Y13 Y12 Y11 Y10 Y09 Y08 Y07 Y06 Y05 Y04 Y03 Y02 Y01

Z14 Z13 Z10 Z09 Z08 Z07 Z06 Z05 Z04 Z03 Z02 Z01

CR1

Detector: TPC C-side (sec. 15, 16, 17)

Fiber cables:8 trunk cables OM3 MPO-MPO (144F)

Path: O-side from FASS (C-side)

Giuseppe Simonetti

UX2(C115)/CR1(Y12)/A: s.n. D-96551 240UX2(C115)/CR1(Y12)/B: s.n. D-96554 243UX2(C115)/CR1(Y12)/C: s.n. D-96555 244UX2(C116)/CR1(Y12)/A: s.n. D-96552 241UX2(C116)/CR1(Y12)/B: s.n. D-96553 242UX2(C116)/CR1(Y12)/C: s.n. D-96556 245UX2(C117)/CR1(Y12)/A: s.n. D-96557 246UX2(C117)/CR1(Y12)/B: s.n. D-96558 247

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

1DAQC1YY12

CR1

|------ -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - --|

|---- -- -- - -- - -- -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- |

TPCC15

TPCC16

TPCC17

1TPCU2YC115

1TPCU2YC116

1TPCU2YC117

TOF

TTC

TOF

DCS

|------ -- - -- - -- -- - -- - -- TRD DAQ ---- -- -- - -- - -- -- - -- - --|

TOF

TTC

TOF

DCS

UX2(C115)/CR1(Y12)/A

UX2(C115)/CR1(Y12)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C115)/CR1(Y12)/C

UX2(C116)/CR1(Y12)/A

UX2(C116)/CR1(Y12)/B

/ 144 Fibers OM3

/ 144 Fibers OM3

/ 144 Fibers OM3UX2(C116)/CR1(Y12)/C

UX2(C117)/CR1(Y12)/A

UX2(C117)/CR1(Y12)/B/ 144 Fibers OM3

/ 144 Fibers OM3

Terminal plate OM33U 12xMPO-MPO

MPO OM3 plug terminated

Blind plate 3U

Terminal plate OM33U 12xMPO-MPO (Spare)

6xE2000/APC SM (spliced)

6xE2000 OM2 (spliced)

12xE2000 OM2 (spliced)

E2000 OM2 plug spliced

E2000/APC SM plug spliced

TOF

TTC

TOF

DCS

00

Terminal plate OM3

3U 2xMPO-24xLC/PC

LC/PC plug terminated

126 m

47

46

45

44

43

42

41

40

39

38

37

36

35

34

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

09

08

07

06

05

04

03

02

01

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

00 01 02 03 04 05 06 07 08 09 10 11

Cord loop inside subrack

D-96551D-96554

D-96555

D-96552D-96553

D-96556

D-96557

D-96558

D-96608