alignment measurement with optical transponder system of … · 2014-03-21 · alignment...

20
Alignment measurement with optical transponder system of Hayabusa-2 LIDAR Hirotomo NODA 1 , Takahide MIZUNO 2 , Hiroo KUNIMORI 3 , Hiroshi TAKEUCHI 2 , Noriyuki NAMIKI 4 1 National Astronomical Observatory of Japan (NAOJ) 2 Japan Aerospace Exploration Agency (JAXA) 3 National Institute of Information and Communications Technology (NICT) 4 Chiba Institute of Technology 1 13-Po06: Noda et al.

Upload: others

Post on 17-Apr-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Alignment measurement with optical transponder system of

Hayabusa-2 LIDAR Hirotomo NODA1, Takahide MIZUNO2, Hiroo KUNIMORI3, Hiroshi TAKEUCHI2, Noriyuki NAMIKI4 1National Astronomical Observatory of Japan (NAOJ) 2Japan Aerospace Exploration Agency (JAXA) 3National Institute of Information and Communications Technology (NICT) 4Chiba Institute of Technology

1

13-Po06: Noda et al.

Page 2: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Introduction

• Japanese Hayabusa-2 is a mission to C-type asteroid 1999 JU 3, and will be launched in 2014 winter

• LIDAR (Laser altimeter) is aboard Hayabusa-2 for navigation and geodetic science.

• LIDAR is equipped with “optical transponder” function for optical link experiment

• Optical link experiment between ground SLR station and Hayabusa-2 LIDAR is scheduled when satellite flies near Earth during Earth Swing-by in 2015 winter.

• The experiment will give the first opportunity to check the performance of LIDAR (link budget, alignment, …)

2

Page 3: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Hayabusa-2 mission to asteroid

3

Year/month events 2014/winter launch 2015/12 Earth gravity assist 2018/6 Arrival at 1999 JU3

remote sensing, sampling

2019/End Departure from 1999 JU3

2020/12 re-entry to Earth Research based on sample data

Page 4: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Target asteroid 1999 JU3

Earth orbit

Mars orbit

Name 1999 JU3

Diameter 0.9 km

Albedo 0.05-0.07

Spectral type C

Rotation period 7.63 hours

1999 JU3

4

Page 5: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Hayabusa2 LIDAR CAD drawing of LIDAR

LIDAR Transmitter

Receiver

To asteroid

+Z +X

+Y

wavelength 1064 nm

Laser power 10 mJ

Repetition rate 1 Hz

Pulse width <10 nsec

Transmitter FOV 1 mrad

Receiver FOV (far) 1.5 mrad

Range resolution 0.5 m

R 5 5 (@25k ) 1 (@30 )

Specification of LIDAR 5

Page 6: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Science targets by LIDAR

• Shape modeling and gravity measurement gives average porosity of target asteroid, which is important to characterize the asteroid

• Albedo measurement at laser wavelength: with visible and Near-IR albedo data, it will constrain the surface material

• Detection of levitation dust : so far there is no observational evidences of circum-asteroid environment. If detected, it will be the first observation of dust around asteroids.

6

Page 7: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Measurement requirement • Porosity is a key

parameter to characterize asteroids

• Porosity can be estimated from volume and mass

• 10% uncertainty ←density 10% ←volume 5%, mass3% ←radius< 2 %( ~10m)

Figure 2. Relation of effective diameter and bulk porosity of asteroids. In addition to estimates by Baer et al. [2011], data taken from literatures are shown. Inferred internal structures such as fractured, monolithic and rubble-pile are based on classification by Britt et al. [2002]. Microscopic porosity is assumed to be 10 % that is a typical value of meteorites.

7

(Namiki et al, submitted)

Page 8: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

8

Dust Detection

Wait time

Dust count range

1999JU3 1999JU3

RARR from Earth

Gravity measurement

free-fall & LIDAR ranging

1999JU3

LIDAR ranging & Visible image data -> shape model

Shape modeling & albedo

LIDAR Rx/ Tx power ratio -> surface albedo

Optical link experiment

Page 9: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Hayabusa vs Hayabusa-2 alignment measurement

• In Hayabusa, NIRS has 1 um band, where the LIDAR footprint could be detected so that the LIDAR boresight direction was determined within 1.7 mrad (0.1 deg) FOV of NIRS.

• In Hayabusa-2, no sensitivity at 1 um range in NIRS3*.

• Optical link experiment gives opportunity to determine alignment w.r.t. spacecraft.

• As FOV of LIDAR transmitter is 1 mrad and spacecraft attitude error is 0.5 mrad, boresight direction will be determined within 1.5 mrad.

• 1.5mrad accuracy satisfies the requirement of the volume measurement of asteroid.

Abe et al. Science 2006 Fig. 1 9 *NIRS3 = Near Infrared Spectrometer at 3 μm

Page 10: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Telescope parameters parameter NICT 1.5m LIDAR Transmitter wavelength, nm 1064 1064 Laser pulse energy, mJ 1200 10 Repetition frequency, Hz 10 1 Pulse width, ns 10 <10 Beam divergence, mrad 0.01 1 Receiver Telescope diameter, m 1.5 0.11 Detector FOV, mrad 0.1 1.5 Pointing Pointing accuracy, mrad ~ 0.01 (~2 arcsec) 0.5 (attitude stability) Scanning Scan rate, mrad/s TBD ( arcsec step) 0.5 TBD Scan amplitude, mrad TBD 5

10

Page 11: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Link equation

0)( LGrLLGPP rsprttts •••••••= ηηUplink case, the receiving power Ps [W] (uplink) is calculated as follows:

Uplink : NICT 1.5m -> LIDAR Downlink: LIDAR -> NICT1.5m

0)()/( LGrLLGhEN rsprtttqpe ••••••••= ηηνη

11

Downlink case, single photon is detected with APD Geiger mode at ground station, therefore the number of photoelectorn Npe is a measure of detection, which is calculated by using laser energy Et as follows:

, which is converted to output voltage of detector (APD) with 500kV/W responsivity

Page 12: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Link equation: parameters

12

Symbol meaning Value(uplink) Value(downlink)

Transmitter power 120 MW (/pulse) --

Transmitter energy -- 0.01 J

Quantum efficiency -- 0.2

Transmitter efficiency 0.8 0.8

Transmitter gain * 1.6E11 1.6E7

Receiver efficiency 0.5 0.5

Pointing loss 0.487 0.487

Space loss 1.2E-34 @ 0.05 AU

Receiver gain 1.05E11 1.96E13

Other losses 0.5 0.5

tP

tηtGrη

pL)(rLs

rG0L

* Calculated from beam divergence angle

tEqη

Page 13: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Link budget (uplink)

1.00E+00

1.00E+01

1.00E+02

1.00E+03

1.00E+04

1.00E+05

0 0.1 0.2 0.3 0.4 0.5 0.6

APD

outp

ut [m

V]

distance [AU]

APD output Voltage [mV]

APD output [mV]

Detection limit 9mV (18nW)

13

Page 14: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Link budget (Downlink)

1.00E-01

1.00E+00

1.00E+01

1.00E+02

0 0.1 0.2 0.3 0.4 0.5 0.6

num

ber o

f pho

tele

ctro

n

distance [AU]

photoelectron

photoelectron

Possible detection

14

Page 15: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Sun-Spacecraft-Earth angle limitation (SPE angle>120 or 130 degrees)

• The angle between Sun direction and normal of the solar panel must be within 60 (or 50) degrees.

S/C -Z direction = LIDAR boresight

Normal of solar panel

< 60 degrees

SPE angle > 120 degrees Nominal attitude of S/C Solar panel toward Sun

(130)

(50)

15

Page 16: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

SPE angle near Earth Swing-by

• No chance if SPE > 130 is required

• Almost anytime if SPE > 120 is allowed

16

Page 17: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Chances of experiment at Koganei

17

・S/C visible from ground ・SPE angle >120 degrees ・night at ground station 4 hours/day until Dec. 4, 2015

Earth Swing-by

Page 18: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

An example: Nov. 6, 2015

night

S/C elevation>0

Chance of observation

18

Page 19: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

19

Page 20: Alignment measurement with optical transponder system of … · 2014-03-21 · Alignment measurement with optical transponder system of Hayabusa-2 LIDAR . Hirotomo 3NODA. 1, Takahide

Summary

• If opt-link is possible, it can constrain the LIDAR FOV alignment w.r.t. spacecraft within 1.5 mrad.

• Link budget – Uplink: further than the downlink case is possible – Downlink: up to 0.3 AU might be possible

• Chance of observation – 4 hours/day is possible at least within a month

prior to Earth swing-by

20