INKBIRD ITC-1000TEMP. CONTROLLER
Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO WIREWire diagram
1 of 15Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
IMPORTENCE: Please don’t forget to wire the Heating andCooling device to Power supplier and make a circuit.
HOW TO WIRESAMPLES
Tools and Materials:
ITC-1000
ABS project box
Power cords and wires
Power Socket
Terminal Block
2 of 15Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO WIRESAMPLES
3 of 15Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
Attach wires to terminal block
HOW TO WIRESAMPLES
4 of 15Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
Fit to ITC-1000
HOW TO WIRESAMPLES
5 of 15Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
Sample from our customer
HOW TO SETPANEL INSTRUCTION
6 of 15
Up Key: Choose Parameter, Increase Value and Check the Setting Temperature Value
Down Key: Choose Parameter, Decrease Value and Check the Setting Difference Value
Set Key: Entry, Exit and Set Parameters
Power Key: Power On and Off, Confirm the Setting Value, Save and Exit Function
C/F Display: Degrees Celsius or degrees Fahrenheit
PV/SV Display: Display Process Value, Set Value and Parameter Menu
Set Indicator Lamp: On: Parameter Setting Status
Heat Indicator Lamp: On: Heating StartOff: Heating Stop
Cool Indicator Lamp: On: Refrigerating StartOff: Refrigerating StopFlash: Compressor Delay
(Left lamp)
(Right lamp)
Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO SETKEY OPERATING
Check Parameter
In normal working status, press “ ”
key once, it will display the setting
temperature value; press “ ” key
once, it will display the difference
value
7 of 15
Parameter Setting •In normal working status, keep pressing “ ” for more than 3s to enter set mode, set indicator lamp is on, screen displays the first menu code “TS”.
•Press “ ” key or “ ” key to move up or down the menu item and display the menu code.
•Press “ ” key to enter the parameter setting of current menu, the parameter value starts to flash.
•Press “ ” key or “ ” key to adjust the parameter value of current menu.
•After the set, press “ ” key to exit the parameter setting of current menu, the parameter value stops to flash. User can set the other functions as above steps.
•In any status, press “ ” key to save the parameter modified value, and return to the normal temperature value.
•If no operating within 10s, it will exit the menu automatically and return to normal temperature display status, and does not save the parameter of this modification.
Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO SETOPERATING INSTRUCTION•In normal working status, press and hold “ ” key for more than 3s to turn off the controller; in Power-off Status, press and hold
“ ” key for more than 1s to turn on the controller.
•In normal working status, screen displays the current measuring value, the controller switch modes between heating and cooling
automatically.
•If the measuring temperature ≥ temperature set value + difference set value, the controller starts refrigerating, the cool indicator
lamp lights on, and the refrigerating relay is connected. When cool indicator lamp flashes, indicating that the refrigerating device is
under compressor delay protecting status.
•If the measuring temperature ≤ temperature set value, the cool indicator lamp turns off, and the refrigerating relay is disconnected.
•If the measuring temperature ≤ temperature set value - difference set value, the controller starts heating, the heat indicator lamp
lights on, and the heating relay is connected.
•If the measuring temperature ≥ temperature set value, the heat indicator lamp turns off, and the heating relay is disconnected.
8 of 15 Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO SETMENU INSTRUCTION
9 of 15
Code Function Set range Default Note
TSTemperatureSet Value
-50~99.9 oC 10.0 oC
DSDifference SetValue
0.3~15 oC 1.0 oC
PTCompressorDelay
0~10 minutes
3munites
CATemperatureCalibrationValue
-15 oC~15 oC 0 oC
CFFahrenheit orCelsius Setting
C
Code Function Set range Default Note
TSTemperature Set Value
-50~210 oF 50 oF Min. Unit 1 oF
DSDifference Set Value
1~30 oF 3 oF
PTCompressor Delay
0~10 minutes
3 minutes
CATemperature Calibration Value
-15~15 oF 0 oF
CFFahrenheit or Celsius Setting
F
When the set temperature is degrees Celsius When the set temperature is degrees Fahrenheit
Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO SET
SETTING TARGET
Fahrenheit or Celsius Setting:F
CF
Target Temperature: 75 – 85 ℉
TS + DS
Compressor Delay:2 minutes
PT
Temperature Calibration Value:2 ℉
CA
10 of 15
SAMPLE
Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO SETSAMPLEFahrenheit or Celsius Setting: F
keep pressing “ ” for more than3s to enter set mode
Press “ ” key once , and thescreen shows “CF” code
ENTER CF MODE
Press “ ” Key to enter CF setting, use “ ”key or “ ” key, choose “F”.
Press “ ” key to confirm and continue tosetting.
CHOOSE F
11 of 15 Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO SETExample: Target Temperature: 75 – 85 ℉
To get 75-85 F target temperature, you need to set:TS(temperature set value)= 80DS(difference set value) = 5
Press “ ” key and choose “TS”code
ENTER TS MODEPress “ ” Key to enter TS setting, use “ ” keyor “ ” key, choose “80”.
Press “ ” key to confirm and continue to setting.
CHOOSE 80
12 of 15 Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
SAMPLE
Press “ ” key and choose “DS”code
ENTER DS MODEPress “ ” Key to enter DS setting, use “ ” keyor “ ” key, choose “5”.
Press “ ” key to confirm and continue to setting.
CHOOSE 5
HOW TO SETSAMPLECompressor Delay: 2 minutes
Press “ ” key to choose “PT” code
ENTER PT MODE
Press “ ” Key once to enter PT setting, use“ ” key or “ ” key, choose “2”.
Press “ ” key to confirm and continue tosetting.
CHOOSE 2
13 of 15 Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
HOW TO SETSAMPLECA(Temperature Calibration Value)=2
Press “ ” key and choose “CA”code
ENTER CA MODE
Press “ ” Key once to enter CA setting, use“ ” key or “ ” key, choose “2”.
Press “ ” key to confirm and continue tosetting.
CHOOSE 2
14 of 15 Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
IMPORTENCE: after setting, don’t forget to press “ ” key to save the parameter modified value, and return to the normal temperature value.
GET IN TOUCHCONTACT US
ABOUT USINKBIRD is a home automation brand operating around the globe. We specialize in thermostat and lighting control system products.
We pride ourselves on understanding what consumers need and how to fulfill their demand. Since 2010, INKBIRD has enjoyed years ofcontinuous growth thanks to millions of satisfied customers around the world.
At INKBIRD, We look into the latest innovations and find products that can connect with our daily life; ideas that can make our routine tasks easier;technologies that truly enhance our activities.
15 of 15
Email: [email protected]
Website: www.ink-bird.com
INKBIRD Tech. C. L.
Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.
THANK YOU
Contact UsEmail: [email protected] , www.ink-bird.com INKBIRD Tech. C. L.