altivar flange mounting kit...340 360 13.38 14.17 d in mm 150 160 5.90 6.29 e in mm 15 18 0.59 0.70...

8
1/8 E6581354-04 02/2019 Altivar Flange Mounting Kit Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this product. © 2019 Schneider Electric. All Rights Reserved. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • Only appropriately trained persons who are familiar with and understand the contents of this manual and all other pertinent product documentation and who have received safety training to recognize and avoid hazards involved are authorized to work on and with this drive system. Installation, adjustment, repair, and maintenance must be performed by qualified personnel. • The system integrator is responsible for compliance with all local and national electrical code requirements as well as all other applicable regulations with respect to grounding of all equipment. • Many components of the product, including the printed circuit boards, operate with mains voltage. Do not touch. Use only electrically insulated tools. • Do not touch unshielded components or terminals with voltage present. • Motors can generate voltage when the shaft is rotated. Prior to performing any type of work on the drive system, block the motor shaft to prevent rotation. • AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of unused conductors of the motor cable. • Do not short across the DC bus terminals or the DC bus capacitors or the braking resistor terminals. • Before performing work on the drive system: - Disconnect all power, including external control power that may be present. - Place a "Do Not Turn On" label on all power switches. - Lock all power switches in the open position. - Wait 15 minutes to allow the DC bus capacitors to discharge. The DC bus LED is not an indicator of the absence of DC bus voltage that can exceed 800 Vdc. - Measure the voltage on the DC bus between the DC bus terminals (PA/+ and PC/-) using a properly rated voltmeter to verify that the voltage is <42 Vdc. - If the DC bus capacitors do not discharge properly, contact your local Schneider Electric representative. Do not repair or operate the product. • Install and close all covers before applying voltage. Failure to follow these instructions will result in death or serious injury. VW3A9510...VW3A9515 VW3A9510 VW3A9512...515 VW3A9511 E658135404

Upload: others

Post on 25-Jan-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • 1/8E6581354-0402/2019

    Altivar Flange Mounting Kit

    Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibilityis assumed by Schneider Electric for any consequences arising out of the use of this product.© 2019 Schneider Electric. All Rights Reserved.

    DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Only appropriately trained persons who are familiar with and understand the contents of this manual and all other

    pertinent product documentation and who have received safety training to recognize and avoid hazards involved are authorized to work on and with this drive system. Installation, adjustment, repair, and maintenance must be performed by qualified personnel.

    • The system integrator is responsible for compliance with all local and national electrical code requirements as well as all other applicable regulations with respect to grounding of all equipment.

    • Many components of the product, including the printed circuit boards, operate with mains voltage. Do not touch. Use only electrically insulated tools.

    • Do not touch unshielded components or terminals with voltage present.• Motors can generate voltage when the shaft is rotated. Prior to performing any type of work on the drive system, block

    the motor shaft to prevent rotation.• AC voltage can couple voltage to unused conductors in the motor cable. Insulate both ends of unused conductors of

    the motor cable.• Do not short across the DC bus terminals or the DC bus capacitors or the braking resistor terminals.• Before performing work on the drive system:

    - Disconnect all power, including external control power that may be present.- Place a "Do Not Turn On" label on all power switches.- Lock all power switches in the open position.- Wait 15 minutes to allow the DC bus capacitors to discharge. The DC bus LED is not an indicator of the

    absence of DC bus voltage that can exceed 800 Vdc.- Measure the voltage on the DC bus between the DC bus terminals (PA/+ and PC/-) using a properly rated

    voltmeter to verify that the voltage is

  • E6581354-04 www.schneider-electric.com2/8

    Cut and holes

    Flange Mounting Kit

    VW3A9510VW3A9511

    VW3A9510

    ain mm

    260

    310

    10.23

    12.20VW3A9511

    c

    d

    e

    af

    195

    4xØ8

    8xØ8

    6xØ10

    7.67

    g

    ai

    h

    b

    bin mm

    790

    845

    31.10

    33.26

    cin mm

    340

    360

    13.38

    14.17

    din mm

    150

    160

    5.90

    6.29

    ein mm

    15

    18

    0.59

    0.70

    fin mm

    100

    83.5

    3.93

    3.28

    gin mm

    15

    10

    0.59

    0.39

    hin mm

    120

    70

    4.72

    2.75

    iin mm

    80

    91.5

    3.14

    3.60

  • E6581354-04 www.schneider-electric.com3/8

    Cut and holes

    Flange Mounting Kit

    VW3A9512 VW3A9513

    VW3A9512

    ain mm

    280

    280

    11.02

    11.02VW3A9513

    bin mm

    970

    970

    38.18

    38.18

    cin mm

    360

    460

    14.17

    18.11

    din mm

    160

    150

    6.29

    5.90

    ein mm

    15

    15

    0.59

    0.59

    fin mm

    120

    120

    4.72

    4.72

    gin mm

    20

    20

    0.78

    0.78

    hin mm

    60

    60

    2.36

    2.36

    iin mm

    195

    195

    7.67

    7.67

    af

    b b

    g

    i i

    aa

    h

    af

    aa

    h

    c

    eg

    c

    e

    d d4xØ8 8xØ8

    8xØ10

    6xØ8

    8xØ10

    6xØ8

  • E6581354-04 www.schneider-electric.com4/8

    Cut and holes

    Flange Mounting Kit

    VW3A9514VW3A9515

    VW3A9514

    ain mm

    280

    280

    11.02

    11.02VW3A9515

    bin mm

    970

    970

    38.18

    38.18

    cin mm

    610

    685

    24.01

    26.96

    din mm

    160

    160

    6.29

    6.29

    ein mm

    17.5

    17.5

    0.68

    0.68

    fin mm

    120

    120

    4.72

    4.72

    gin mm

    20

    20

    0.78

    0.78

    hin mm

    60

    60

    2.36

    2.36

    iin mm

    215

    240

    8.46

    9.44

    af

    g

    a

    b

    ah

    c

    iii

    e

    d

    195

    7.67

    8xØ8

    8xØ10

    8xØ8

  • E6581354-04 www.schneider-electric.com5/8

    1

    2 3

    4

    VW3A9510

    Mounting

    Flange Mounting Kit

    M4 1.1...1.7 N·m (9.74...15.05 lbf.in)

    M6 4.2...5.1 N·m (37.17...45.14 lbf.in)

  • E6581354-04 www.schneider-electric.com6/8

    5

    6 7

    8 9

    Mounting

    Flange Mounting Kit

    M5 2.6...3.3 N·m (23.01...29.21 lbf.in)

    VW3A9510

  • E6581354-04 www.schneider-electric.com7/8

    2

    1

    Mounting

    Flange Mounting Kit

    VW3A9512...515VW3A9511

    VW3A9511...515

    M8 13.5 N·m (119.5 lbf.in)M6 4.2...5.1 N·m (37.17...45.14 lbf.in)

    VW3A951010

    M12 41 N·m (360 lbf.in)M12

    M8

    M8 10.0...13.5 N·m (88.51...119.49 lbf.in)

  • E6581354-04 www.schneider-electric.com8/8

    3

    4

    Mounting

    Flange Mounting Kit

    5

    M12 M8

    VW3A9511

    M12

    M8

    VW3A9512...515

    M12 41 N·m (360 lbf.in)

    M8 10.0...13.5 N·m (88.51...119.49 lbf.in)

    IS_Flush_mounting_kit_VW3A9510-15_E6581354_01IS_Flush_mounting_kit_VW3A9510-15_E6581354_02IS_Flush_mounting_kit_VW3A9510-15_E6581354_03IS_Flush_mounting_kit_VW3A9510-15_E6581354_04IS_Flush_mounting_kit_VW3A9510-15_E6581354_05IS_Flush_mounting_kit_VW3A9510-15_E6581354_06IS_Flush_mounting_kit_VW3A9510-15_E6581354_07IS_Flush_mounting_kit_VW3A9510-15_E6581354_08