am-tite series non-metallic plugs msr series switched … msr am-tite.pdf · ul 1686 c1 pin &...

5
Compatible with UL 1686 C1 Pin & Sleeve Devices AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Upload: vuongcong

Post on 08-May-2018

227 views

Category:

Documents


1 download

TRANSCRIPT

Compatible with UL 1686 C1

Pin & Sleeve Devices

AM-Tite Series Non-Metallic Plugs

MSR Series Switched and Interlocked Receptacles

MENNEKES® MSR Series Switched and Interlocked

Receptacles incorporate an interlocking receptacle and

disconnect switch in one non-metallic NEMA 4X; 12

enclosure. Units are available both fusible and non-fusible

to meet your application requirements. The patented

interlock mechanism prohibits the switch from being

turned “ON” unless the plug is fully inserted. The plug

cannot be removed unless the unit is turned “OFF”.

Safer. Easier. Better.MENNEKES® Non-Metallic MSR Switched and Interlocked Receptacles

and Non-Metallic AM-Tite series plugs allow you to maintain existing plant

standards, while benefiting from new and innovative designs and materials.

Applications:

• Wet, damp or hose down environments

• Welding Applications

• Portable Pumps and Lift Stations

• Transformer Carts

• Food and Beverage Manufacturing

• Paper and Pulp Industry

• Automotive Plants

• Shipyards

• Cement and Steel Plants

MSR Series Interlocks are used with traditional metal

plugs, or with the new and innovative MENNEKES

AM-Tite Series plugs. These next generation UL

1686 configured plugs are easier to install and

are compatible with mating devices from other

manufacturers. With AM-tite plugs, you can maintain

existing plant standards while promoting operator

safety inherent with non-metallic devices.

NEMA 4X AM-Tite Non-Metallic

Plugs available in 30A & 60A

AM-Tite Series Non-Metallic PlugsMSR Series Switched and Interlocked Receptacles

MSR Interlock mated

with traditional metal plug

The MSR Series Receptacles conform to UL Standard

1686 C1 configurations assuring interchangeability with

other manufacturers. Units meet OSHA requirements for

lockout/tagout (Reg. 1910.147) and prevent arc-flash.

MENNEKES Interlocked Receptacles operate in harsh

environments and facilitate operator safety when providing

power to welders, pumps, break-out packaging equipment

and various other uses.

AM-Tite Plug mated

to metal devices;

compatible with other

manufacturers with

Style 2 grounding

Generous wiring space allows for convenient accessto field terminals.

Fusible version onlyRemovable fuse holders allow for fuse replacement away from circuit. Risk of touching live parts is minimized versus traditional “knife style” switches. (fuses not provided).

NEMA 4X Valox® enclosure; impact modified and chemical resistant. Featurespoured-in-place gasketing and molded conduit drill points in top/bottom/rear walls.

Corner mounting tubes minimize mounting footprint.Moveable mounting feet also provided.

Fusible Interlocked Receptacles

Compliance:

Standards 98; 1682 & 1686

to CSA Standard C22.2 No. 4-M89, Enclosed Switches

Environmental: Type 4X, 12; IP 66 Suitable

Construction:

Enclosure: Valox with Nylon Handle

Hardware: Stainless Steel and Ni plated Brass

Insulator: Thermoset Polyester

Contacts: Brass with Beryllium Copper Spring

Gaskets: Fermapor Polyurethane & NBR

Receptacle Cover: Cu free Aluminum with

Epoxy Powder Coat

Ratings:

Receptacles: 30A & 60A, 600Vac in 3Wire 4Pole

Grounding: Style 2

Switch: Fusible w/Type J Fuse Clips,

600Vac Capable

Short Circuit: 100kAIC w/Fuses

3Ø HP Rating: 10 to 50HP Max Ratings

Factory wired switch to receptacle, available fusible or non-fusible. (fusible version shown)

High visibility, pad-lockable handle actuates switch and receptacle interlockmechanism to assure “no-load” make and break of plug connected equipment.

Thermoset receptacle to UL 1686 C1 configurations;UL Classified for combination use with competing brand plugs.

Threaded stainless steel ring provides NEMA 4X rating with locking plugs;UL tested.

Dust tight and watertight rated cover;field replaceable.

Hidden hinge system eliminates sanitationconcerns; provides access to interior forfuse replacement, if applicable.

7” Width mounts in web of standardI-beam. Compact design is ideally suited to retrofits when comparedto current industry alternatives.

MSR Series Switched and Interlocked Receptacles 30 Amp and 60 Amp, Fusible and Non-Fusible

Compliance:

Standards 508; 1682 & 1686

to CSA Standard C22.2 No. 14-M95

Environmental: Type 4X, 12; IP 66 Suitable

Construction:

Enclosure: Valox with Nylon Handle

Hardware: Stainless Steel and Ni plated Brass

Insulator: Thermoset Polyester

Contacts: Brass with Beryllium Copper Spring

Gaskets: Fermapor Polyurethane & NBR

Receptacle Cover: Cu free Aluminum with

Epoxy Powder Coat

Ratings:

Receptacles: 30A & 60A, 600Vac in 3Wire 4Pole

Grounding: Style 2

Switch: Heavy Duty, 600Vac Capable

Short Circuit: 65kA RMS Symmetrical when protected

by equally-sized Class J Fuse

3Ph HP Rating: 5 to 50HP

* Valox is a trademark of SABIC Innovative Plastics, acquired from General Electric Company.

Non-Fusible Interlocked Receptacles

DIN rail and screw mounting of components allow for easeof maintenance.

Compliance and Ratings

MSR Optional Auxiliary Contacts

Amps Fusible Non-Fusible

Catalog Number Catalog Number

30A ME30FDAUX ME30AUX

1 N/O or 1 N/C 1 N/O and 1 N/C

60A ME60FDAUX-0 ME80AUX

1 N/O 1 N/O and 1 N/C

60A ME60FDAUX-C N/A

1 N/C

Amps Type Poles/ Voltage MSR Interlocks Mating Plug Mating Plug

Wires Catalog Numbers Catalog Numbers Catalog Numbers

(non-metallic) (metallic)

30A Fusible 3W 4P 600VAC MSR430MIFS2W ME3034NM ME3034BC

30A Non-Fusible 3W 4P 600VAC MSR430MIS2W ME3034NM ME3034BC

60A Fusible 3W 4P 600VAC MSR460MIFS2W ME6034NM ME6034BC

60A Non-Fusible 3W 4P 600VAC MSR460MIS2W ME6034NM ME6034BC

Electrical

Dielectric Voltage Withstands 3,000 VAC Min.

Max. Working Voltage 250VDC/600VAC

Max. Short Circuit Rating

– Fusible MSR; 100,000 RMS Symmetrical Amperes w/fuses

– Non-Fusible MSR; 65,000 RMSSymmetrical Amperes

Operations (min)

– Fusible; 6,000 Electrical 20,000 Mechanical

– Non-Fusible; 10,000 Electrical 100,000 Mechanical

Fuse Type(s)

30A & 60A – Type J

Fuse Type(s) - not provided 30A & 60A – Type J 30A - Type CC Option Available

Mechanical

Impact Resistance Per UL 746C

Terminal Identification Per UL/CSA and Accepted

International Conventions

Product Ratings – Identification & General Rating

on External Label – HP Ratings per Operating Voltages

on Internal Label

Mounting Moveable Mounting Feet or

Use of Corner Mounting Tubes

Environmental

Moisture Resistance – Type 4X (Watertight, Washdown)

per UL 50E

– Type 12K (Dusttight, Falling Dirt) per UL 50E

International Rating IP66 Suitability, per IEC 60529

Flammability UL94-5V0 and V0 Classification

Operating Temperatures Max. Continuous: +60° C Min. Continuous: -40° C

without impact

UV Resistance Enclosure & Handle Materials are UV Stabilized

MSR Replacement Parts

Description Fusible Non-Fusible

30A Replacement Switch ME30XFDSJ ME30MIX

60A Replacement Switch ME60XFDSJ ME60MIX

30A Cover Assembly ME3430MIFRC2W ME3430MIRC2W

60A Cover Assembly ME3460MIFRC2W ME3460MIRC2W

30A Chain Cover for Receptacle MEPTTC30 MEPTTC30

60A Chain Cover for Receptacle MEPTTC60 MEPTTC60

30A Threaded Cover Ring ME3430MI2SSR ME3430MI2SSR

60A Threaded Cover Ring ME3460MI2SSR ME3460MI2SSR

30A Contact Carrier - 3W 4P MEARI3034 MEARI3034

60A Contact Carrier - 3W 4P MEARI6034 MEARI6034

Max HP Ratings

Amp Type Single Phase (Volts) Three Phase (Volts)

120 240 208 240 480 600

30 Fusible 2 3 7.5 7.5 15 20

30 Non-Fusible 2 5 10 10 20 20

60 Fusible – 7.5 15 15 30 50

60 Non-Fusible 3 10 20 20 40 50

Ordering Information

MSR Performance

Dimensions & Ratings; 30 Amp and 60 Amp MSR Interlocks

Visit www.MENNEKES.com for spec sheets and mechanical drawings.

Approximate Dimensions (in inches)

A B C D E F G H

30A 11.50 7.00 6.34 13.00 .20 7.23 8.45 13.46

60A 11.50 7.00 6.34 13.00 .20 7.23 8.93 14.45

Also available in traditional metal version

AM-Tite Non-Metallic Plugs; 30 Amp and 60 Amp

Sure-grip Rubberized Locking Ring

Provides high impact protection

and NEMA 4X Rating

Coarse Rugged Threading

Facilitates quick assembly

Molded Gaskets

Permanently molded to the housing for

watertight seal. Unique design assures

gaskets will never be lost or misaligned.

Ready to Wire Terminals

Provided with backed out terminal screws

and large wire chamber to speed installation

Oversized Terminal Screws

Preferred by installers

Strain Relief Assembly

Accommodates wide cable range

which easily threads into NPT housing

Rugged Housing

Offers outstanding insulation for user safety.

Innovative design and engineered materials

provide a durable alternative to traditional

metal products.

Specifications

UL Standards: 1682; 1686; 50E- TYPE 4X;12

Configuration: 30A & 60A 3W 4P Style 2 Ground (C1)

Housing Material: Impact Modified PBT Polyester

Hardware: Stainless Steel or Ni Plated

Outdoor Use: UV Stabilized Housing and Gasket Materials

Mennekes

electrical Products

277 Fairfield Road

Fairfield, NJ 07004

Tel: (800) 882-7584

Fax: (973) 882-5585

Email: [email protected]

Internet: www.MENNEKES.com

©2016 MENNEKES Electronics, Inc. ME 3108 8/2016