amendment sheet - acson international · amendment sheet manual : wall mounted split system code :...

26
Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up Description : Add In Model and Typing Amendment Amendment on Manual’s Page No. : 1 Product Line-Up Outdoor Unit ALC-C Series Cap Tube Gold Coated Bare Contactor High Pressure Switch Low Pressure Switch Scroll Rotary CE Back Panel Grille Super Tropical Specification ACPOE X X X X ACPIE X X X X ACPOD X X X X ACPID X X X X ACPOB X X X X ACPIB X X X X ACPOD X X X X ACPID X X X X ACPOD X X X X ACPID X X X X ACPBD X X X X X ACPOD X X X X ACPID X X X X ACPBD X X X X X ACPHB X X X X X X ACPOD X X X X ACPID X X X X ACPBD X X X X X ACPHB X X X X X X ACHOB X X X ACHIB X X X ACHBB X X X X 30C AFGE X X X X X X PCB COOLING ALC 10C 15C 18C 20C 28C FIN Nomenclature Classification Marking Others Special 07C Safety Devices Compressor Refrigerant Control 09C 25C 5

Upload: truongthuy

Post on 04-May-2018

224 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Product Line Up

Description : Add In Model and Typing Amendment

Amendment on Manual’s Page No. :

1

Product Line-Up

Outdoor Unit

ALC-C Series

Cap

Tu

be

Go

ld C

oa

ted

Bare

Co

nta

cto

r

Hig

h P

res

su

re S

wit

ch

L

ow

Pre

ssu

re S

wit

ch

S

cro

ll

Ro

tary

CE

Bac

k P

an

el

Gri

lle

S

up

er

Tro

pic

al

Sp

ec

ific

ati

on

ACPOE X X X X

ACPIE X X X X

ACPOD X X X X

ACPID X X X X

ACPOB X X X X

ACPIB X X X X

ACPOD X X X X

ACPID X X X X

ACPOD X X X X

ACPID X X X X

ACPBD X X X X X

ACPOD X X X X

ACPID X X X X

ACPBD X X X X X

ACPHB X X X X X X

ACPOD X X X X

ACPID X X X X

ACPBD X X X X X

ACPHB X X X X X X

ACHOB X X X

ACHIB X X X

ACHBB X X X X

30C AFGE X X X X X X

P

CB

CO

OL

ING

ALC

10C

15C

18C

20C

28C

F

IN

No

me

nc

latu

re

Classification

M

ark

ing

O

the

rs

S

pec

ial

07C

S

afe

ty D

ev

ice

s

C

om

pre

ss

or

R

efr

ige

ran

t

C

on

tro

l

09C

25C

5

Page 2: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Product Line Up

Description : Add In Model and Typing Amendment

Amendment on Manual’s Page No. :

2

Outdoor Unit

ALC-CR Series

C

ap

Tu

be

T

XV

G

old

Co

ate

d

B

are

C

on

tac

tor

H

igh

Pre

ss

ure

Sw

itch

Lo

w P

res

su

re S

wit

ch

Sc

roll

R

ota

ry

C

E

D

rain

Elb

ow

S

up

er

Tro

pic

al

Sp

ecif

icati

on

ACPOD X X X X

ACPID X X X X

ACPOB X X X X

ACPIB X X X X

ACPOA X X X X

ACPIA X X X X

ACPOD X X X X

ACPID X X X X

ACPOD X X X X

ACPID X X X X

ACPHB X X X X X

ACPOD X X X X

ACPID X X X X

ACPHB X X X X X

ACHOB X X X X

ACHIB X X X X

30CR AFFB X X X X X X X X

ALC

No

me

ncla

ture

Classification

P

CB

R

efr

ige

ran

t

C

on

tro

l

F

IN

S

afe

ty D

ev

ice

s

C

om

pre

ss

or

M

ark

ing

O

thers

S

pe

cia

l

HE

AT

PU

MP

09CR

10CR

15CR

18CR

20CR

25CR

28CR

6

Page 3: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Refrigerant Diagram

Description : Amendment In Refrigerant Diagram For AWM301 - ALC28C

Amendment on Manual’s Page No. :

3

Refrigerant Circuit Diagram

Model: AWM301 – ALC28C

12

Page 4: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Refrigerant Diagram

Description : Add In Refrigerant Diagram For AWM301/R - ALC28C/CR

Amendment on Manual’s Page No. : NIL

4

Model: AWM301 – ALC30C

Page 5: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Refrigerant Diagram

Description : Add In Refrigerant Diagram For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. :

5

Model: AWM301R –ALC30CR

NIL

Page 6: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

6

Engineering & Physical Data

General Data - Cooling Only (R22)

AWM - 20G AWM - 20G

ALC - 18C ALC - 20C

Btu/h 18000 19000

W 5280 5570

W 1820 1807

A 8.10 8.00

V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

W/W 2.90 3.08

R22 R22

OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL LCD REMOTE CONTROL

l/s / CFM 231 / 490 231 / 490

l/s / CFM 193 / 410 193 / 410

l/s / CFM 160 / 340 160 / 340

dBA 43 / 40 / 35 43 / 40 / 35

mm/in 304 / 12.0 304 / 12.0

mm/in 1062 / 41.8 1062 / 41.8

mm/in 222 / 8.7 222 / 8.7

mm/in 378 / 14.9 378 / 14.9

mm/in 1130 / 44.5 1130 / 44.5

mm/in 292 / 11.5 292 / 11.5

kg/lb 16 / 35.3 16 / 35.3

mm/in 20 / 0.8 20 / 0.8

l/s / CFM 614 / 1300 614 / 1300

dBA 51 51

mm/in 654 / 25.7 654 / 25.7

mm/in 855 / 33.7 855 / 33.7

mm/in 328 / 12.9 328 / 12.9

mm/in 710 / 28.0 710 / 28.0

mm/in 990 / 39.0 990 / 39.0

mm/in 415 / 16.3 415 / 16.3

kg/lb 58 / 127.9 59 / 130.1

FLARE VALVE FLARE VALVE

LIQUID mm/in 6.35 / 1/4 6.35 / 1/4

GAS mm/in 15.88 / 5/8 15.88 / 5/8

kg/lb 0.80 / 1.76 1.35 / 2.981) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

REFRIGERANT CHARGE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

POWER SOURCE

EER

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL RUNNING CURRENT

37

Page 7: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

7

General Data - Cooling Only (R22)

AWM - 25G AWM - 301

ALC - 25C ALC - 28C

Btu/h 23500 27000

W 6890 7913

W 2530 2708

A 11.30 13.10

V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

W/W 2.72 3.00

R22 R22

OUTDOOR CAP. TUBE EXTERNAL ORIFICE KIT

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

AUTO LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL LCD REMOTE CONTROL

l/s / CFM 297 / 630 316 / 670

l/s / CFM 231 / 490 297 / 630

l/s / CFM 208 / 440 236 / 500

dBA 49 / 44 / 42 49 / 47 / 45

mm/in 304 / 12.0 360 / 14.2

mm/in 1062 / 41.8 1200 / 47.2

mm/in 222 / 8.7 200 / 7.9

mm/in 378 / 14.9 420 / 16.5

mm/in 1130 / 44.5 1267 / 49.9

mm/in 292 / 11.5 260 / 10.2

kg/lb 16 / 35.3 17 / 37.48

mm/in 20 / 0.8 20 / 0.8

l/s / CFM 755 / 1600 741 / 1570

dBA 52 54

mm/in 756 / 29.8 756 / 29.8

mm/in 855 / 33.7 855 / 33.7

mm/in 328 / 12.9 328 / 12.9

mm/in 810 / 31.9 810 / 31.9

mm/in 990 / 39.0 990 / 39.0

mm/in 415 / 16.3 415 / 16.3

kg/lb 62 / 136.7 65 / 143.3

FLARE VALVE FLARE VALVE

LIQUID mm/in 9.52 / 3/8 9.52 / 3/8

GAS mm/in 15.88 / 5/8 15.88 / 5/8

kg/lb 1.5 / 3.30 1.75 / 3.861) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL RUNNING CURRENT

POWER SOURCE

EER

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

REFRIGERANT CHARGE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

38

Page 8: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

8

General Data - Cooling Only (R22)

AWM - 301

ALC - 30C

Btu/h 30000

W 8790

W 2944

A 12.60

V/Ph/Hz 220 - 240 / 1 / 50

W/W 2.99

R22

EXTERNAL ORIFICE KIT

AUTO LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL

l/s / CFM 316 / 670

l/s / CFM 297 / 630

l/s / CFM 236 / 500

dBA 49 / 47 / 45

mm/in 360 / 14.2

mm/in 1200 / 47.2

mm/in 200 / 7.9

mm/in 420 / 16.5

mm/in 1267 / 49.9

mm/in 260 / 10.2

kg/lb 17 / 37.48

mm/in 20 / 0.8

l/s / CFM 1605 / 3400

dBA 58

mm/in 850 / 33.5

mm/in 1030 / 40.6

mm/in 400 / 15.6

mm/in 1000 / 39.4

mm/in 1200 / 47.2

mm/in 560 / 22.1

kg/lb 95 / 209.4

FLARE VALVE

LIQUID mm/in 9.52 / 3/8

GAS mm/in 15.88 / 5/8

kg/lb 1.60 / 3.531) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL RUNNING CURRENT

POWER SOURCE

EER

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

REFRIGERANT CHARGE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

NIL

Page 9: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

9

General Data - Heat pump (R22)

AWM - 09GR AWM - 10GR

ALC - 09CR ALC - 10CR

Btu/h 8800 9500

W 2580 2780

Btu/h 8600 9500

W 2520 2780

W 910 860

W 750 750

A 4.00 3.80

A 3.40 3.40

V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

W/W 2.84 3.23

W/W 3.36 3.71

R22 R22

OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL LCD REMOTE CONTROL

l/s / CFM 130 / 275 142 / 300

l/s / CFM 106 / 225 118 / 250

l/s / CFM 83 / 175 94 / 200

dBA 40 / 35 / 29 39 / 34 / 28

mm/in 260 / 10.2 260 / 10.2

mm/in 799 / 31.5 899 / 35.4

mm/in 198 / 7.8 198 / 7.8

mm/in 337 / 13.3 337 / 13.3

mm/in 857 / 33.7 957 / 37.7

mm/in 270 / 10.6 270 / 10.6

kg/lb 10 / 22.5 12 / 26.5

mm/in 16 / 0.6 16 / 0.6

l/s / CFM 307 / 650 396 / 840

dBA 46 46

mm/in 495 / 19.5 540 / 21.3

mm/in 600 / 23.6 700 / 27.6

mm/in 245 / 9.7 250 / 9.8

mm/in 575 / 22.6 620 / 24.4

mm/in 715 / 28.1 810 / 31.9

mm/in 330 / 13.0 330 / 13.0

kg/lb 28 / 61.7 32 / 70.5

FLARE VALVE FLARE VALVE

LIQUID mm/in 6.35 / 1/4 6.35 / 1/4

GAS mm/in 9.52 / 3/8 9.52 / 3/8

kg/lb 0.60 /1.32 0.63 / 1.391) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

WIDTH

UNIT DIMENSION

UNIT WEIGHT

PIPE CONNECTION

WIDTH

DEPTH

HEIGHT

REFRIGERANT CHARGE

IND

OO

R U

NIT

AIR FLOW

DEPTH

PACKING

DIMENSION

HEIGHT

DEPTH

OU

TD

OO

R U

NIT

TYPE

SIZE

HEIGHT

NOMINAL RUNNING CURRENT (HEATING)

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

LOW

EER

COP

POWER SOURCE

SOUND PRESSURE LEVEL (H/M/L)

WIDTHUNIT DIMENSION

AIR FLOW

INDOOR UNIT

CONTROLAIR DISCHARGE

HIGH

MODELOUTDOOR UNIT

NOMINAL RUNNING CURRENT (COOLING)

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

NOMINAL COOLING CAPACITY

MEDIUM

OPERATION

SOUND PRESSURE LEVEL

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

39

Page 10: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

10

General Data - Heat pump (R22)

AWM - 301R AWM - 301R

ALC - 28CR ALC - 30CR

Btu/h 27000 30000

W 7913 8790

Btu/h 27000 30000

W 7913 8790

W 2708 2944

W 2273 2864

A 13.20 14.30

A 13.30 13.70

V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

W/W 2.92 2.99

W/W 3.48 3.07

R22 R22

OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL LCD REMOTE CONTROL

l/s / CFM 316 / 670 316 / 670

l/s / CFM 297 / 630 297 / 630

l/s / CFM 236 / 500 236 / 500

dBA 49 / 47 / 45 49 / 47 / 45

mm/in 360 / 14.2 360 / 14.2

mm/in 1200 / 47.2 1200 / 47.2

mm/in 200 / 7.9 200 / 7.9

mm/in 420 / 16.5 420 / 16.5

mm/in 1267 / 49.9 1267 / 49.9

mm/in 260 / 10.2 260 / 10.2

kg/lb 17 / 37.48 17 / 37.48

mm/in 20 / 0.8 20 / 0.8

l/s / CFM 741 / 1570 1605 / 3400

dBA 54 58

mm/in 756 / 29.8 850 / 33.5

mm/in 855 / 33.7 1030 / 40.6

mm/in 328 / 12.9 400 / 15.8

mm/in 810 / 31.9 1000 / 39.4

mm/in 990 / 39.0 1200 / 47.2

mm/in 415 / 16.3 560 / 22.1

kg/lb 68 / 150 95 / 209

FLARE VALVE FLARE VALVE

LIQUID mm/in 9.52 / 3/8 9.52 / 3/8

GAS mm/in 15.88 / 5/8 15.88 / 5/8

kg/lb 1.83 / 4.03 2.15 / 4.741) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

NOMINAL RUNNING CURRENT (COOLING)

NOMINAL RUNNING CURRENT (HEATING)

POWER SOURCE

EER

COP

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

REFRIGERANT CHARGE

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

42

Page 11: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

11

General Data - Cooling Only (R22)

A5WM - 07G A5WM - 09G

A5LC - 07C A5LC - 10C

Btu/h 7500 9000

W 2200 2640

W 620 860

A 2.90 3.90

V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

W/W 3.55 3.07

R410A R410A

OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL LCD REMOTE CONTROL

l/s / CFM 130 / 275 130 / 275

l/s / CFM 106 / 225 106 / 225

l/s / CFM 83 / 175 83 / 175

dBA 40 / 35 / 29 40 / 35 / 29

mm/in 260 / 10.2 260 / 10.2

mm/in 799 / 31.5 799 / 31.5

mm/in 198 / 7.8 198 / 7.8

mm/in 337 / 13.3 337 / 13.3

mm/in 857 / 33.7 857 / 33.7

mm/in 270 / 10.6 270 / 10.6

kg/lb 10 / 22.0 10 / 22.0

mm/in 16 / 0.6 16 / 0.6

l/s / CFM 307 / 650 396 / 840

dBA 44 46

mm/in 495 / 19.5 540 / 21.3

mm/in 600 / 23.6 700 / 27.6

mm/in 245 / 9.7 250 / 9.8

mm/in 575 / 22.6 620 / 24.4

mm/in 715 / 28.1 810 / 31.9

mm/in 330 / 13.0 330 / 13.0

kg/lb 26 / 57.3 32 / 70.5

FLARE VALVE FLARE VALVE

LIQUID mm/in 6.35 / 1/4 6.35 / 1/4

GAS mm/in 9.52 / 3/8 9.52 / 3/8

kg/lb 0.48 / 1.06 0.73 / 1.611) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

REFRIGERANT CHARGE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

POWER SOURCE

EER

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL RUNNING CURRENT

43

Page 12: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

12

General Data - Cooling Only (R410A)

A5WM - 10G A5WM - 15G

A5LC - 10C A5LC - 15C

Btu/h 9500 12000

W 2780 3520

W 910 1230

A 3.90 5.40

V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

W/W 3.05 2.86

R410A R410A

OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL LCD REMOTE CONTROL

l/s / CFM 142 / 300 163 / 345

l/s / CFM 118 / 250 135 / 285

l/s / CFM 94 / 200 104 / 220

dBA 39 / 34 / 28 42 / 36 / 29

mm/in 260 / 10.2 260 / 10.2

mm/in 899 / 35.4 899 / 35.4

mm/in 198 / 7.8 198 / 7.8

mm/in 337 / 13.3 337 / 13.3

mm/in 957 / 37.7 957 / 37.7

mm/in 270 / 10.6 270 / 10.6

kg/lb 12 / 26.5 12 / 26.5

mm/in 16 / 0.6 16 / 0.6

l/s / CFM 396 / 840 453 / 960

dBA 46 49

mm/in 540 / 21.3 540 / 21.3

mm/in 700 / 27.6 700 / 27.6

mm/in 250 / 9.8 250 / 9.8

mm/in 620 / 24.4 620 / 24.4

mm/in 810 / 31.9 810 / 31.9

mm/in 330 / 13.0 330 / 13.0

kg/lb 33 / 70.5 32 / 70.5

FLARE VALVE FLARE VALVE

LIQUID mm/in 6.35 / 1/4 6.35 / 1/4

GAS mm/in 9.52 / 3/8 12.70 / 1/2

kg/lb 0.73 / 1.61 0.83 / 1.831) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

REFRIGERANT CHARGE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

POWER SOURCE

EER

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL CAPACITY

NOMINAL TOTAL INPUT POWER

NOMINAL RUNNING CURRENT

44

Page 13: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

13

General Data - Cooling Only (R410A)

A5WM - 311

A5LC - 28C

Btu/h 26000 / <26000>

W 7620 / <7620>

W 2560 / <2631>

A 12.2 / <4.6>

V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50>

W/W 2.98 / <2.90>

R410A

OUTDOOR CAP. TUBE

AUTO LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL

l/s / CFM 316 / 670

l/s / CFM 297 / 630

l/s / CFM 236 / 500

dBA 49 / 47 / 45

mm/in 360 / 14.2

mm/in 1200 / 47.2

mm/in 200 / 7.9

mm/in 420 / 16.5

mm/in 1267 / 49.9

mm/in 260 / 10.2

kg/lb 17 / 37.5

mm/in 20 / 0.8

l/s / CFM 632 / 1340

dBA 54

mm/in 756 / 29.8

mm/in 855 / 33.7

mm/in 328 / 12.9

mm/in 810 / 31.9

mm/in 990 / 39.0

mm/in 415 / 16.3

kg/lb 68 / 149.9

FLARE VALVE

LIQUID mm/in 9.52 / 3/8

GAS mm/in 15.88 / 5/8

kg/lb 1.80 / 3.971) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL CAPACITY-1Ø/ <3Ø>

NOMINAL TOTAL INPUT POWER-1Ø/ <3Ø>

NOMINAL RUNNING CURRENT-1Ø/ <3Ø>

POWER SOURCE-1Ø/ <3Ø>

EER-1Ø/ <3Ø>

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

REFRIGERANT CHARGE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

46

Page 14: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

14

General Data - Heat pump (R410A)

A5WM - 07GR A5WM - 09GR

A5LC - 07CR A5LC - 10CR

Btu/h 7500 9000

W 2200 2640

Btu/h 7500 9000

W 2200 2640

W 680 860

W 550 745

A 3.10 3.90

A 2.60 3.40

V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

W/W 3.24 3.07

W/W 4.00 3.54

R410A R410A

OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

DOUBLE LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL LCD REMOTE CONTROL

l/s / CFM 130 / 275 130 / 275

l/s / CFM 106 / 225 106 / 225

l/s / CFM 83 / 175 83 / 175

dBA 40 / 35 / 29 40 / 35 / 29

mm/in 260 / 10.2 260 / 10.2

mm/in 799 / 31.5 799 / 31.5

mm/in 198 / 7.8 198 / 7.8

mm/in 337 / 13.3 337 / 13.3

mm/in 857 / 33.7 857 / 33.7

mm/in 270 / 10.6 270 / 10.6

kg/lb 10 / 22.0 10 / 22.0

mm/in 16 / 0.6 16 / 0.6

l/s / CFM 307 / 650 396 / 840

dBA 44 46

mm/in 495 / 19.5 540 / 21.3

mm/in 600 / 23.6 700 / 27.6

mm/in 245 / 9.7 250 / 9.8

mm/in 575 / 22.6 620 / 24.4

mm/in 715 / 28.1 810 / 31.9

mm/in 330 / 13.0 330 / 13.0

kg/lb 26 / 57.3 32 / 70.5

FLARE VALVE FLARE VALVE

LIQUID mm/in 6.35 / 1/4 6.35 / 1/4

GAS mm/in 9.52 / 3/8 9.52 / 3/8

kg/lb 0.50 /1.10 0.73 / 1.611) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING)

NOMINAL TOTAL INPUT POWER (HEATING)

NOMINAL RUNNING CURRENT (COOLING)

NOMINAL RUNNING CURRENT (HEATING)

POWER SOURCE

EER

COP

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

REFRIGERANT CHARGE

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

47

Page 15: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Amendment On Engineering And Physical Data

Amendment on Manual’s Page No. :

15

General Data - Heat pump (R410A)

A5WM - 301R

A5LC - 28CR

Btu/h 26000 / <26000>

W 7620 / <7620>

Btu/h 26000 / <26000>

W 7620 / <7620>

W 2560 / <2631>

W 2442 / <2294>

A 12.2 / <4.6>

A 11.6 / <4.2>

V/Ph/Hz 220-240/ 1/ 50 / <380-415/ 3/ 50>

W/W 2.98 / <2.90>

W/W 3.12 / <3.32>

R410A

OUTDOOR CAP. TUBE

AUTO LOUVER (UP & DOWN) &

GRILLE (LEFT & RIGHT)

LCD REMOTE CONTROL

l/s / CFM 316 / 670

l/s / CFM 297 / 630

l/s / CFM 236 / 500

dBA 49 / 47 / 45

mm/in 360 / 14.2

mm/in 1200 / 47.2

mm/in 200 / 7.9

mm/in 420 / 16.5

mm/in 1267 / 49.9

mm/in 260 / 10.2

kg/lb 17 / 37.5

mm/in 20 / 0.8

l/s / CFM 632 / 1340

dBA 54

mm/in 756 / 29.8

mm/in 855 / 33.7

mm/in 328 / 12.9

mm/in 810 / 31.9

mm/in 990 / 39.0

mm/in 415 / 16.3

kg/lb 68 / 149.9

FLARE VALVE

LIQUID mm/in 9.52 / 3/8

GAS mm/in 15.88 / 5/8

kg/lb 1.80 / 3.971) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :

a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR

b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

MODELINDOOR UNIT

OUTDOOR UNIT

NOMINAL COOLING CAPACITY- 1Ø / <3Ø>

NOMINAL HEATING CAPACITY- 1Ø / <3Ø>

NOMINAL TOTAL INPUT POWER (COOLING)- 1Ø / <3Ø>

NOMINAL TOTAL INPUT POWER (HEATING)- 1Ø / <3Ø>

NOMINAL RUNNING CURRENT (COOLING)- 1Ø / <3Ø>

NOMINAL RUNNING CURRENT (HEATING)- 1Ø / <3Ø>

POWER SOURCE- 1Ø / <3Ø>

EER- 1Ø / <3Ø>

COP- 1Ø / <3Ø>

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

IND

OO

R U

NIT

CONTROLAIR DISCHARGE

OPERATION

AIR FLOW

HIGH

MEDIUM

LOW

SOUND PRESSURE LEVEL (H/M/L)

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

CONDENSATE DRAIN SIZE

OU

TD

OO

R U

NIT

AIR FLOW

SOUND PRESSURE LEVEL

UNIT DIMENSION

HEIGHT

WIDTH

DEPTH

PACKING

DIMENSION

REFRIGERANT CHARGE

HEIGHT

WIDTH

DEPTH

UNIT WEIGHT

PIPE CONNECTION

TYPE

SIZE

50

Page 16: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Add In Data For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. :

16

Components Data - Cooling Only (R22)

AWM - 301

ALC - 30C

CROSS FLOW FAN

1

ACRYLO NITRILE STYRENE

DIRECT

mm/in 106 / 4.17

mm/in 950 / 37.4

INDUCTION

1

IP24

PROPELLER

1

GLASS REINFORCED ACRYL STYRENE

RESIN

DIRECT

mm/in 610 / 24

INDUCTION

1

-

SCROLL

MINERAL (Sontex 200 LT)

cm3 / fl.oz. 1240 / 43.6

SEAMLESS INNER COPPER TUBE

mm/in 9.52 / 0.375

mm/in 0.35 / 0.013

ALUMINIUM (HYDROPHILIC SLIT FIN

TYPE)mm/in 0.11 / 0.0043

m2/ft

2 0.291 / 3.130

2

16

SEAMLESS COPPER TUBE

mm/in 9.52/ 0.375

mm/in 0.35 / 0.014

ALUMINIUM (SLIT FIN TYPE)

mm/in 0.12 / 0.005

m2/ft

2 0.87 / 9.33

1

16

SARANET + IONIZER

pc 3 X 3

LENGTH mm/in 330 / 13.0

WIDTH mm/in 317 / 12.4

THICKNESS mm/in 1.8 / 0.07

NO

MATERIAL ABS

COLOUR LIGHT GREY

MATERIAL GALVANISED MILD STEEL

COLOUR LIGHT GREY

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

MODELINDOOR UNIT

OUTDOOR UNIT

INDOOR FAN

TYPE

QUANTITY

MATERIAL

DRIVE

DIAMETER

LENGTH

INDOOR FAN

MOTOR

TYPE

QUANTITY

INDEX OF PROTECTION (IP)

OUTDOOR FAN

TYPE

QUANTITY

MATERIAL

DRIVE

DIAMETER

ROW

OUTDOOR FAN

MOTOR

TYPE

QUANTITY

INDEX OF PROTECTION (IP)

COMPRESSOR

TYPE

OIL TYPE

OIL AMOUNT

FACE AREA

INDOOR COIL

TUBE

MATERIAL

DIAMETER

THICKNESS

FIN

MATERIAL

THICKNESS

FACE AREA

NEGATIVE IONIZER

FIN PER INCH

OUTDOOR COIL

TUBE

MATERIAL

DIAMETER

THICKNESS

FIN

MATERIAL

THICKNESS

CASING

INDOOR UNIT

OUTDOOR UNIT

ROW

FIN PER INCH

AIR QUALITYFILTER

TYPE

QUANTITY

SIZE

NIL

Page 17: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Engineering And Physical Data

Description : Add In Data For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. :

17

Components Data - Heatpump (R22)

AWM - 301R AWM - 301R

ALC - 28CR ALC - 30CR

ANTI FUNGUS CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN

1 1

ACRYLO NITRILE STYRENE ACRYLO NITRILE STYRENE

DIRECT DIRECT

mm/in 106 / 4.17 106 / 4.17

mm/in 950 / 37.4 950 / 37.4

INDUCTION INDUCTION

1 1

IP24 IP24

PROPELLER PROPELLER

1 1

GLASS REINFORCED ACRYL STYRENE

RESIN

GLASS REINFORCED ACRYL STYRENE

RESIN

DIRECT DIRECT

mm/in 457.2/18 610.0/24

INDUCTION INDUCTION

1 1

IP54 -

ROTARY HERMETIC SCROLL

ATMOS M60 or SUNISO 4GDID MINERAL (Sontex 200 LT)

cm3 / fl.oz. 1130 / 39.8 1240 / 43.6

SEAMLESS INNER GROOVE COPPER SEAMLESS COPPER TUBE

mm/in 9.52 / 0.375 9.52 / 0.375

mm/in 0.35 / 0.013 0.35 / 0.013

ALUMINIUM (HYDROPHILIC SLIT FIN TYPE) ALUMINIUM (HYDROPHILIC SLIT FIN TYPE)

mm/in 0.11 / 0.0043 0.11 / 0.004

m2/ft

2 0.291 / 3.130 0.291 / 3.130

2 2

16 16

SEAMLESS INNER GROOVE COPPER SEAMLESS COPPER TUBE

mm/in 9.52 / 3/8 9.52 / 3/8

mm/in 0.33 / 0.013 0.33 / 0.013

ALUMINIUM (SLIT FIN) ALUMINIUM (SLIT FIN)

mm/in 0.11 / 0.004 0.12/ 0.005

m2/ft

2 0.61 / 6.52 0.87 / 9.33

2 2

18 16

SARANET + IONIZER SARANET + IONIZER

pc 3 X 3 3 X 3

LENGTH mm/in 330 / 13.0 330 / 13.0

WIDTH mm/in 317 / 12.4 317 / 12.4

THICKNESS mm/in 1.8 / 0.07 1.8 / 0.07

NO NO

MATERIAL ABS ABS

COLOUR LIGHT GREY LIGHT GREY

MATERIAL GALVANISED MILD STEEL GALVANISED MILD STEEL

COLOUR LIGHT GREY LIGHT GREY

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

MATERIAL

TYPE

QUANTITY

MATERIAL

ROW

FIN PER INCH

DIAMETER

THICKNESS

THICKNESS

FACE AREA

COMPRESSOR

TYPE

OIL TYPE

INDEX OF PROTECTION (IP)

OUTDOOR FAN

MOTOR

OIL AMOUNT

QUANTITY

DIAMETER

LENGTH

OUTDOOR FAN MATERIAL

DRIVE

TYPE

TYPE

QUANTITY

DIAMETER

INDOOR UNIT

OUTDOOR UNITMODEL

TYPE

INDOOR FAN

INDOOR FAN

MOTOR

QUANTITY

MATERIAL

DRIVE

INDEX OF PROTECTION (IP)

INDOOR COIL

OUTDOOR COIL

FIN

FIN

TUBE

TUBE

CASING

FILTER

SIZE

QUANTITY

TYPE

INDOOR UNIT

OUTDOOR UNIT

NEGATIVE IONIZER

AIR QUALITY

MATERIAL

MATERIAL

ROW

FIN PER INCH

DIAMETER

THICKNESS

THICKNESS

FACE AREA

58

Page 18: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Performance Data

Description : Add In Performance Data For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. : NIL

18

Performance Data

Cooling Only (R22)

Model : AWM301 – ALC30C

Page 19: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Performance Data

Description : Add In Performance Data For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. : NIL

19

Heat Pump (R22) Model : AWM301R – ALC30CR

Cooling Mode

Model : AWM301R – ALC30CR

Heating Mode

Page 20: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Outline Dimension

Description : Add In Outline Dimension For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. : NIL

20

Outline and Dimension

Indoor Unit

Model : AWM 301/301R

Outdoor Unit

Model : ALC 30C/CR

Page 21: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Electrical Data

Description : Add In Electrical Data For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. :

21

Electrical Data

Electrical Data – Cooling Only (R22) AWM - 301

ALC - 30C

CLASS B

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50

RATED INPUT POWER W 71

RATED RUNNING CURRENT A 0.30

MOTOR OUTPUT W 40

4

CLASS B

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50

RATED INPUT POWER W 220

RATED RUNNING CURRENT A 1.02

MOTOR OUTPUT W 145

8

-

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50

CAPACITOR µµµµF 50.0

RATED INPUT POWER W 2377

RATED RUNNING CURRENT A 11.50

LOCKED ROTOR AMP. A 82

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

MODELINDOOR UNIT

OUTDOOR UNIT

INDOOR MOTOR

INSULATION GRADE

POLES

OUTDOOR MOTOR

INSULATION GRADE

POLES

COMPRESSOR

INSULATION GRADE

Electrical Data – Heat Pump (R22) AWM - 301R AWM - 301R

ALC - 28CR ALC - 30CR

CLASS B CLASS B

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

RATED INPUT POWER W 71 71

RATED RUNNING CURRENT A 0.30 0.30

MOTOR OUTPUT W 75 75

4 4

CLASS B CLASS B

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

RATED INPUT POWER W 142 220

RATED RUNNING CURRENT A 0.62 1.02

MOTOR OUTPUT W 75 145

6 8

CLASS E -

POWER SOURCE V/Ph/Hz 220 - 240 / 1 / 50 220 - 240 / 1 / 50

CAPACITOR µµµµF 50.0 50.0

RATED INPUT POWER (COOLING) W 2570 2377

RATED INPUT POWER (HEATING) W 2610 2584

RATED RUNNING CURRENT (COOLING) A 12.30 11.50

RATED RUNNING CURRENT (HEATING) A 12.40 12.30

LOCKED ROTOR AMP. A 66 82

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

MODELINDOOR UNIT

OUTDOOR UNIT

INDOOR MOTOR

INSULATION GRADE

POLES

COMPRESSOR

INSULATION GRADE

OUTDOOR MOTOR

INSULATION GRADE

POLES

103

Page 22: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Wiring Diagram

Description : Add In Wiring Diagram For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. : NIL

22

Wiring Diagram

Cooling Only Model

Indoor Unit

Model : AWM301

Outdoor Unit

Model : ALC30C

Page 23: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Wiring Diagram

Description : Add In Wiring Diagram For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. : NIL

23

Heat Pump Model

Indoor Unit

Model : AWM301R

Outdoor Unit

Model : ALC30CR

Page 24: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Exploded View And Parts List

Description : Add In Exploded View and Parts List For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. :

24

Exploded View and Parts List

Outdoor Unit

Model : ALC30C

1 Assy. Base Pan R50014053238 13 Fan Motor R03039004046

2 Assy. 3 Way VLV 3/8" R50059030464 14 Fan Blade R03013028160

3 Assy. 3 Way VLV 5/8" R50059030532 15 Assy. Front Panel R50014053236

4 Assy. Panel, Partition R50014053277 16 Valve Plate R01013034235

5 Assy. Compressor R50049013221 Part Not In Diagram

6 Service Panel R01010029898 Capacitor, Compressor R04029026779

7 Accumulator R02119025988 Capacitor, Fan Motor R04029026761

8 Panel, Back Right R01014053233Y Pressure Switch R04109031314

9 Top Panel R01011029900 Contactor R04039018866

10 Assy. Coil R50024041851 Fan Guard R01023030109

11 Fan Motor Bracket R01014053232 Assy. Terminal Board Main R50044067920

12 Panel Side Left R01013029899

No Description Part Number No Description Part Number

NIL

Page 25: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

Amendment Sheet

Manual : Wall Mounted Split System Code : AWM-G-2009-0002

Subject : Exploded View and Parts List

Description : Add In Exploded View and Parts List For AWM301/R – ALC30C/CR

Amendment on Manual’s Page No. :

25

Outdoor Unit

Model : ALC30CR

1 Assy. Base Pan R50014053238 13 Fan Motor R03039004046

2 Assy. 3 Way VLV 3/8" R50059030464 14 Fan Blade R03013028160

3 Assy. 3 Way VLV 5/8" R50059030532 15 Assy. Front Panel R50014053236

4 Assy. Panel, Partition R50014053277 16 Valve Plate R01013034235

5 Assy. Compressor R50049013221 Part Not In Diagram

6 Service Panel R01010029898 Capacitor, Compressor R04029026779

7 Accumulator R02114013198 Capacitor, Fan Motor R04029026761

8 Panel, Back Right R01014053233Y Pressure Switch R04109031314

9 Top Panel R01011029900 Contactor R04039018866

10 Assy. Coil R50024035282 Fan Guard R01023030109

11 Fan Motor Bracket R01014053232 Assy. Terminal Board Main R50044067926

12 Panel Side Left R01013029899 Valve, 4-Way R05029001991

No Description Part Number No Description Part Number

NIL

Page 26: Amendment Sheet - Acson International · Amendment Sheet Manual : Wall Mounted Split System Code : AWM-G-2009-0002 Subject : Product Line Up ... mm/in 810 / 31.9 810 / 31.9 mm/in

26

Revision Table

Code Subject Amendment on

Manual’s Page No. Date

AWM-G-2009-0001 New Low Ambient Range Launching NIL 29.4.2009

AWM-G-2009-0002 Amendment For WM Split System Manual 5,6,12,37-39,42-

44,46,47,50,58,103 02.7.2009