amp - latronics · use only a 96v-110v turbine. makes sure the turbine does not already have a...

4
INSTRUCTION MANUAL and WARRANTY REGISTRATION CARD Ph 61 7 5491 6988 web: www.latronics.com.au email: [email protected] Latronics P.O. Box 73 Moffat Beach Qld 4551 AUSTRALIA A NEW WORLD POWER ® LATRONICS P.O. BOX 73 MOFFAT BEACH QLD 4551 AUSTRALIA Please Affix Stamp Here TC96 Turbine Controller 25 AMP For use with PVE2500 Grid Connect Inverter

Upload: others

Post on 28-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AMP - Latronics · Use only a 96V-110V turbine. Makes sure the turbine does not already have a controller. Please remove if this is the case. The turbine must be used in conjunction

INSTRUCTION MANUALand

WARRANTY REGISTRATION CARD

Ph

61

7 5

49

1 6

98

8

web: w

ww

.latro

nic

s.c

om

.au e

mail: s

ale

sl@

latro

nic

s.c

om

.au

Latro

nic

s P

.O. B

ox 7

3 M

offa

t Beach

Qld

4551

AU

ST

RA

LIA

AN

EW

WO

RL

DP

OW

ER

®

LA

TR

ON

ICS

P.O

. BO

X 7

3M

OF

FA

T B

EA

CH

QL

D 4

551

AU

ST

RA

LIA

Ple

ase

Affix

Sta

mp

Here

TC96Turbine Controller

25 AMP

For use with PVE2500 Grid Connect Inverter

Page 2: AMP - Latronics · Use only a 96V-110V turbine. Makes sure the turbine does not already have a controller. Please remove if this is the case. The turbine must be used in conjunction

WELCOME

Latronics

Latronics

Latronics

Latronics

products are all proudly designed, engineered andmanufactured in Australia. As a specialist renewable energy companywe produce this turbine controller for battery-less connection to the

Grid Connected inverter.

In order to produce the most reliable products available,products have been designed to endure the most rugged terrain andthe harshest conditions across the Australian continent.

All products are engineered using the latest high quality componentsand manufactured to stringent quality standards, thus ensuring

customers all enjoy many years of trouble free operation.

It is important to us at , that our clients enjoy the maximumbenefits from our Inverters in a safe and productive environment. Sowe strongly advise that you read through the next few pages of thismanual, which explains all the modes of operation and relevant safetyprecautions for your new Turbine Controller.

Please remember to complete either your registration card ORcomplete the online registration to validate your warrantyPlease retain your receipt as proof of purchase.

PVE2500

LATRONICS

PO BOX 73

MOFFAT BEACH Q 4551

PH: 61 7 5491 6988 FAX: 61 7 5491 6792

EMAIL: sales

WEB: www.latronics.com.au

@latronics.com.au

Se

ria

l N

o.................................... D

ate

ca

rd r

etu

rne

d..............................

IMPO

RTA

NT !

As a

n e

nviro

nm

en

tally c

on

sc

ious c

usto

me

r yo

u m

ay c

ho

ose

to

Re

gis

ter

on

lin

e a

t http

://la

tro

nic

s.c

om

.au .

On

ce

co

mp

lete

d

on

lin

e the

re is n

o n

ee

d to

po

st th

is r

eg

istra

tio

n c

ard

.

RE

GIS

TR

AT

ION

CA

RD

Your

warr

anty

is o

nly

valid

if th

is c

ard

or

onlin

e r

egis

tration is c

om

ple

ted w

ithin

3 m

onth

s o

f th

e d

ate

of purc

hase.

Nam

e:...................................................................................

.Serial N

o:.................................................

Date

of P

urc

hase:............................................S

upplie

r:................................................................................................................

?R

esid

ential

Com

merc

ial

Sola

r B

atteries W

ind O

ther

Featu

res V

alu

e for

Money

Appeara

nce R

ecom

mendation W

arr

anty

Austr

alia

n M

ade

Fair G

ood V

ery

Good E

xcelle

nt

Above E

xpecta

tions

Yes N

o

Com

ments

:...........................................................................

.......................................................................................................................................................................................................

* W

here

is y

our

Contr

olle

r bein

g u

sed

......................

* W

as y

our

decis

ion m

ade b

ecause o

f?

* H

ow

do y

ou r

ate

the s

erv

ice fro

m y

our

supplie

r?

* D

id y

our

new

Contr

olle

r m

eet your

expecta

tions?

.Post code:......................

Em

ail

/ P

hone (

optional):..................................................................

*W

hat E

nerg

y S

ourc

e is c

onnecte

d to y

our

contr

olle

r?

Copyright Latronics. Doc No A340-D10-V03-Q2 06/10

Page 3: AMP - Latronics · Use only a 96V-110V turbine. Makes sure the turbine does not already have a controller. Please remove if this is the case. The turbine must be used in conjunction

Wind and Solar Configuration

4 1

Solar Panels

PV Edge

Grid Inverter

TurbineController

Grid MainsTurbine

3 Phase or DC Voltage

Voltage 96V

Voltage Type Input 3 Phase AC or DC

Current 25A

Brake System Electronic PWM Brake

Brake Voltage 150V

Weight 2kg

Connections Screw Terminal Junction Box

Chassis Powder Coated 2mm Aluminium

Dimensions 260mm x 160mm x 100mm

Warranty 2 years

Ratings Specifications @ 25ºC

TC96 Specifications

SYSTEM DIAGRAM

PV Edge

Grid Inverter

TurbineController

Grid Mains

Turbine

3 Phase or DC Voltage

The Latronics Turbine Controller utilises the latest in micro-controllerdesign to deliver a stable and safe supply of power to the grid connectinverter. Designed specifically to integrate with the Latronics PVE2500Grid Connect Inverter, it allows battery-less grid connection of DC or 3phase AC wind and water turbines.

Electronic Smart Brake:

Multiple Input Types:

Versatile and Reliable:

The electronic braking system progressivelyincreases the braking until the turbine comes to a complete stop. Thiswill extend bearing life and prevent damage to both the PV Edge andTurbine during extreme conditions.

The Latronics turbine controllers come standardwith a voltage rectifier. This means 3 phase AC or DC Voltage can befed in to the Turbine controller.

Suitable for use with wind generators, micro-hydro and other renewable turbine sources. Over 25 years ofexperience and continuous adherence to stringent quality standardsensures optimum reliability backed with a full 2 year parts and labourwarranty

Load Dump

IIIIIIIIII Load Dump

IIIIIIIIII

Page 4: AMP - Latronics · Use only a 96V-110V turbine. Makes sure the turbine does not already have a controller. Please remove if this is the case. The turbine must be used in conjunction

2 3

IndicatorsGreen LED Flashing

Green LED On

Red LED On

: Indicates there is power butinsufficient levels to begin feeding

: Indicates there is sufficient powerto feed the grid.: Indicates the turbine is over-

spinning and the electronic Smart Braking systemis functional

On Switch32A DC breaker to safely turn on and off the

Turbine Controller and protect from over current

Ventilation Holes

For Cool, Fan-less operation

Input Junction BoxTo connect either 3 phase

or DC voltage from turbineAC

Output LeadsTo connect to PV-Edge UsingAnderson Connector supplied

with PVE2500

Important Notes Before Installation

Turbine Requirements

!

!

!

!

!

!

!

!

The unit must be placed in a well ventilated and protected area,not exposed to the open environment, and free fromcontaminates (i.e. Exhaust gases, sea air, dust etc.)The Turbine Controller is designed for indoor installation in asuitable location where ambient temperature will not exceedrated values.As the Turbine Controller has a wall mountable enclosure,ensure proper air circulation for cooling.When attaching the turbine to the Turbine Controller, polarity andor wire sequence does not matter due to the internal rectifier.Due to dangerous voltages, do not disconnect any wiring untilthe unit has completely powered down with no lights flashingand the turbine has stopped or been disconnected.

Use only a 96V-110V turbine.Makes sure the turbine does not already have a controller.Please remove if this is the case.The turbine must be used in conjunction with a load dump thatwas supplies with the turbine.

WARNING!PV-Edge Grid-connect Inverter must be in battery mode

WARNING!Do not operate load dump connected, as this will

cause damage to the turbine controller and PV-Edge inverter.

(See PV Edge Manual)

without

It is important that all wiring in the installation complies with the relevantstandards (AS4777 / AS3100)

Any work carried out is to be performed by Qualified and Licensedpersonnel

Load DumpTo connect external load dump

supplied with turbine