FKWCSJMT
CONTACT US FOR DETAILSGLYN
D38999/26
Lanyard Release Plug
D38999/24D38999/20
HERMETICS
D38999/20 F A35 P N -LCSHELL STYLE FINISH LAYOUT CONTACT POLARIZATION MODIFIER
1 2 3 4 5 6
STEP 1:
RECEPTACLES PLUGSMates with
STEP 2:
!"#$%#&%'()$*+(,-(.$/01(-2/*#3*(40(526(7'*#$%01
!"#
!"###$%$&'()*+,-$./%0./$.12%3.&1.$'
2-%4.-%!"###$3*12*3$222
For assistance in Europe, please see the back cover for a complete listing of our branch offices and contact numbers.Specifications subject to change.
Military Contacts
P - Pin inserts only (Contact us for socket availability)Note: MS connector G75 is supplied with size 8 twinax Propriety connector 21-75 is supplied with size 8 coax
Coax Twinax J20 is supplied with 2-#12 coax and 2-#12 shielded contacts
Contact us for more information.
D38999 Total Layout Number 22D 20 16 12 10 8 A35 M 6 6 P A98 I 3 3 P B2 I 2 2 B5 I 5 5 P B35 M 13 13 P B98 I 6 6 P B99 I 7 7 C4 I 4 4 P C8 I 8 8 P C35 M 22 22 P C98 I 10 10 P D5 II 5 5 P D15 I 15 14 1 P D18 I 18 18 P D19 I 19 19 P D35 M 37 37 P D97 I 12 8 4 P E2 M 39 38 1 E6 I 6 6 P E8 II 8 8 P E26 I 26 26 P E35 M 55 55 P E99 I 23 21 2 F11 II 11 11 P F18 M 18 14 4 F28 I 28 26 2 F32 I 32 32 P F35 M 66 66 P G11 I 11 11 G16 II 16 16 P G35 M 79 79 P G39 I 39 37 2 P G41 I 41 41 P G75 M 4 4 (See Note) H21 II 21 21 P H35 M 100 100 P H53 I 53 53 P H55 I 55 55 P J4 I 56 48 8 P J7 TWINAX 99 97 2 J8 TWINAX 8 8 J11 N 11 2 9 J19 I 19 19 P J20 N 30 10 13 4 3 J24 I 24 12 12 P J29 I 29 29 J35 M 128 128 P J37 I 37 37 J43 I 43 23 20 2 J46 I 46 40 4 2 J61 I 61 61 P J90 I 46 40 4 2
Service Rating
SHELL MINOR KEY LOCATION SIZE AR! & AP! BR! & BP! CR! & CP! DR! & DP! A N 105 140 215 265 A 102 132 248 320 B 80 118 230 312 C 35 140 205 275 D 64 155 234 304 E 91 131 197 240 B N 95 141 208 236 C A 113 156 182 292 D B 90 145 195 252 C 53 156 220 255 D 119 146 176 298 E 51 141 184 242 E N 80 142 196 293 F A 135 170 200 310 B 49 169 200 244 C 66 140 200 257 D 62 145 180 280 E 79 153 197 272 G N 80 142 196 293 H A 135 170 200 310 B 49 169 200 244 J C 66 140 200 257 D 62 145 180 280 E 79 153 197 272
LC
Available in Hermetic Pin Layouts
UNIVERSAL MOD UUSUTUWSB or HSB
CG
CA
STEP 3:For listing by # of contacts, "##$%&'#"$()*+((),
STEP 4:
PSHJAB
NABCD
STEP 5:
STEP 6:
!"#
!"###$%$&'()*+,-$./%0./$.12%3.&1.$'
2-%4.-%!"###$3*12*3$222
For assistance in North America: +1 800.642.8750 for Pricing/Delivery or +1 800.523.0727 @peigenesis.com
TV06/TVS06CTV06/CTVS06
TVS06RB_W88
TV09/TVS09
TV01/TVS01CTV01/CTVS01
TVP00/TVPS00CTVP00/CTVPS00
TV07/TVS07CTV07/CTVS07
TVP02/TVPS02CTVP02/CTVPS02
NOTE: For high-vibration and harsh-environment applications. Please contact us. (TV26/HTV26)
# Not Firewall Capable
NOTE: To be used with Service Classes RF, RK & RS only for 200°C. TVS/CTVS TVPS/CTVPS
TVP00 RW- 9-35 P - -LCSHELL STYLE FINISH LAYOUT CONTACT POLARIZATION MODIFIER
1 2 3 4 5 6
STEP 1:
RECEPTACLES PLUGSMates with
HERMETICS
!"#$%#&%'()$*+(,-(.$/01(-2/*#3*(40(526(7'*#$%01
RBRFRKRWRSZNDT
CONTACT US FOR DETAILSYYNRGFRGWRQFRQWRGQFRGQWRQK #RX
STEP 2:
!"#
!"###$%$&'()*+,-$./%0./$.12%3.&1.$'
2-%4.-%!"###$3*12*3$222
For assistance in Europe, please see the back cover for a complete listing of our branch offices and contact numbers.Specifications subject to change.
Not tooled for 02-R Q = Available in Quadrax Layouts25-20 is supplied with 2-#12 coax and 2-#12 shielded contacts Coax Twinax Power Contact us for more information.
G = Groundplane option available. 9-5 is exclusively groundplane.Note: Propriety connector 21-75 is supplied with size 8 coax
9-5QG Grounded 1 1 9-35 M 6 6 P 9-94 M 2 2 9-98 I 3 3 P 11-01 Twinax 1 1 11-2 G I 2 2 11-4 4 4 11-5 I 5 5 P 11-35 M 13 13 P 11-54 II 4 4 11-98 I 6 6 P 11-99 I 7 7 13-4G I 4 4 P 13-8 I 8 8 P 13-13 I,Fibre Optic 4 2 2 13-35 M 22 22 P 13-98 I 10 10 P 15-4 I 4 4 15-5G II 5 5 P 15-15 I 15 14 1 P 15-18 I 18 18 P 15-19 I 19 19 P 15-35 M 37 37 P 15-97 I 12 8 4 P 17-2 M 39 38 1 17-6 I 6 6 P 17-8G II 8 8 P 17-20 M 20 16 4 17-22 Q Coax 4 2 2 17-26 I 26 26 P 17-35 M 55 55 P 17-52Q M 2 2 17-60Q I/Coax 10 8 2 17-99 I 23 21 2 19-ADQ I/Twinax 17 16 1 19-11G II 11 11 P 19-17 M 17 10 1 4 2 19-18 Q M 18 14 4 19-28 I 28 26 2 19-31 Q M 15 12 1 2 19-32 I 32 32 P 19-35 M 66 66 P 21-11G I 11 11 21-16G II 16 16 P 21-29 I 27 19 4 4 21-35 M 79 79 P 21-39 I 39 37 2 P 21-41 I 41 41 P 21-48 4 4 21-75QG M 4 4 (See Note) 21-79Q II 19 17 2 23-6QG M 6 6 23-14 I 14 14 23-21G II 21 21 P 23-35 M 100 100 P 23-53 I 53 53 P 23-54 M 53 40 9 4 23-55 I 55 55 P 25-4 I 56 48 8 P 25-7 Q Twinax 99 97 2 25-8 QG Twinax 8 8 25-11 N 11 2 9 25-17 M 42 36 6 25-19G I 19 19 P 25-20 Q N 30 10 13 4 3 25-24G I 24 12 12 P 25-26 I 25 16 5 4 25-29G I 29 29 25-35 M 128 128 P 25-37 G I 37 37 25-41 I 41 22 3 11 2 3 25-43 I 43 23 20 25-46 Q I 46 40 4 2 25-61 I 61 61 P 25-62 Q I 12 8 4 25-90 I 46 40 4 2 25-F4 M/I 66 49 13 4
Commercial ontacts Contacts Available in Hermetic Pin Layouts
TV/CTV Total Layout Number 22D 20 16 12 10 8
Service Rating
!""#$%&"#'() for more Modifiers.
SHELL MINOR KEY LOCATION SIZE AR* & AP* BR* & BP* CR* & CP* DR* & DP* 9 N 105 140 215 265 A 102 132 248 320 B 80 118 230 312 C 35 140 205 275 D 64 155 234 304 E 91 131 197 240 11 N 95 141 208 236 13 A 113 156 182 292 15 B 90 145 195 252 C 53 156 220 255 D 119 146 176 298 E 51 141 184 242 17 N 80 142 196 293 19 A 135 170 200 310 B 49 169 200 244 C 66 140 200 257 D 62 145 180 280 E 79 153 197 272 21 N 80 142 196 293 23 A 135 170 200 310 25 B 49 169 200 244 C 66 140 200 257 D 62 145 180 280 E 79 153 197 272
LC
W52W88
STEP 4:
PSHJAB
ABCDE
STEP 5:
STEP 6:
STEP 3:For listing by # of contacts, +""#$%&"+#'(,-''(.
!"#
!"###$%$&'()*+,-$./%0./$.12%3.&1.$'
2-%4.-%!"###$3*12*3$222
For assistance in North America: +1 800.642.8750 for Pricing/Delivery or +1 800.523.0727 @peigenesis.com
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
-9-942-#20
M
CONTACTS 1 2 3 4
B211-22-#16
I
A989-983-#20
I
-11-544-#22D
II
-13-13
2-#16, 2-#12I,
FIBER OPTIC
C413-44-#16
I
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 4
-15-44-#12
I
-17-22 Q
2-#12 , 2-#8COAX
G7521-75Q
4-#8 orM
B511-55-#20
I
D515-55-#16
II
B9811-986-#20
I
E617-66-#12
I
A359-35
6-#22DM
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
C813-88-#20
I
E817-88-#16
II
J825-8 Q8-#8TWINAX
CONTACTS 5 6
-23-6Q6-#8
M
B9911-997-#20
I
C9813-9810-#20
I
-11-44-#20
I
-21-48
4-#8-
-17-60Q
8-#22D, 2-#8I/COAX
-17-52Q2-#8
M
-9-5Q1-#8
M
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 7 8 10
Coax Twinax Power Not Tooled for 02-R Q Quadrax Contact us for more information.
-11-01
1-#8TWINAX
!"#
!"###$%$&'()*+,-$./%0./$.12%3.&1.$'
2-%4.-%!"###$3*12*3$222
For assistance in Europe, please see the back cover for a complete listing of our branch offices and contact numbers.Specifications subject to change.
-17-20
16-#22D, 4-#12M
F1119-1111-#16
II
G1121-1111-#12
I
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 11 12
J1125-11
2-#20, 9-#10N
D9715-97
8-#20, 4-#16I
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
-19-31 Q
12-#22D, 1-#12, 2-#8M
D1515-15
14-#20,1-#16I
G1621-1616-#16
II
CONTACTS 13 14 15 16
B3511-35
13-#22DM
-23-1414-#12
I
-21-79Q
17-#22D, 2-#8II
F1819-18 Q
14-#22D, 4-#8M
D1815-1818-#20
I
D1915-1919-#20
I
J1925-1919-#12
I
-19-ADQ
16-#20, 1#8I/TWINAX
-19-17
10-#22D,1-#20, 4-#16, 2-#8M
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 19 20
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 17 18
-25-62Q
8-#16, 4-#8I
Coax Twinax Power Not Tooled for 02-R Q Quadrax Contact us for more information.
!!"
!"###$%$&'()*+,-$./%0./$.12%3.&1.$'
2-%4.-%!"###$3*12*3$222
For assistance in North America: +1 800.642.8750 for Pricing/Delivery or +1 800.523.0727 @peigenesis.com
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 29 30 32 37
F2819-28
26-#20, 2-#16I
J2925-2929-#16
I
J2025-20 Q
10-#20, 13-#16, 4-#12 , 3-#8N
F3219-3232-#20
I
Coax Twinax Power Not Tooled for 02-R Q Quadrax Contact us for more information.
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 37 39 41
D3515-35
37-#22DM
1
2131
J3725-3737-#16
I
E217-2
38-#22D, 1-#8M
G3921-39
37-#20;2-#16I
G4121-4141-#20
I
-21-29
19-#20, 4-#16, 4-#12I
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
E2617-2626-#20
I
CONTACTS 25 26 27 28
J2425-24
12-#16, 12-#12I
-25-26 Q
16-#20, 5-#12, 4-#8I
E9917-99
21-#20, 2-#16I
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
C3513-35
22-#22DM
CONTACTS 21 22 23 24
H2123-2121-#16
II
-25-41
22-#22D, 3-#20, 11-#16, 2-#12 , 3-#8I
25-20 is supplied with 2-#12 coax and 2-#12 shielded contacts
!!"
!"###$%$&'()*+,-$./%0./$.12%3.&1.$'
2-%4.-%!"###$3*12*3$222
For assistance in Europe, please see the back cover for a complete listing of our branch offices and contact numbers.Specifications subject to change.
-25-17
36-#22D, 6-#8M
J4325-43
23-#20, 20-#16I
J4625-46 Q
40-#20, 4-#16, 2-#8I
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 42 43 46
J9025-90
40-#20, 4-#16, 2-#8I
H5323-5353-#20
I
E3517-35
55-#22DM
-23-54
40-#22D, 9-#16, 4-#12M
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
CONTACTS 53 55
H5523-5555-#20
I
J425-4
48-#20, 8-#16I
J6125-6161-#20
I
-25-F4
49-#22D, 13-#16, 4-#12M/I
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
J725-7 Q
97-#22D, 2-#8TWINAX
H3523-35
100-#22DM
J3525-35
128-#22DM
CONTACTS 56 61 66
F3519-35
66-#22DM
G3521-35
79-#22DM
CONTACTS 79 99 100 128
D38999 LAYOUTTV/CTV LAYOUT
# OF CONTACTSSERVICE RATING
Coax Twinax Power Not Tooled for 02-R Q Quadrax Contact us for more information.