1.ipaso lct setting
Post on 12-Nov-2014
127 Views
Preview:
DESCRIPTION
TRANSCRIPT
NEC Confidential
© PT. NEC Indonesia 2010 NEC ConfidentialPage 2
LCT COMMUNICATION INTERFACELCT COMMUNICATION INTERFACETHE LOCAL CRAFT TERMINAL IS USED TO SETUP, MONITOR AND MAINTAIN iPASOLINK RADIO. iPASOLINK SUPPLY USER GUI ENVIRONMENT THROUGH WEB BROWSER. LCT SUPPORTS BOTH LOCAL AND REMOTE
CONNECTIONS
WINDOWS XP WINDOWS VISTA & WINDOWS 7
CPU PENTIUM-M 1.6 GHz OR BETTER
INTEL CORE2 DUO 1.6 GHz
RAM 512 MB OR MORE 1 GB
HDD 40 GB OR MORE FREE CAPACITY
40 GB OR MORE FREE CAPACITY
DISPLAY COLOR LCD (1024x768) COLOR LCD (1024x768)
LAN PORT
10/100 Base T(X) 10/100 Base T(X)
SOFTWARE REQUIREMENT
OSWIN DOWS XP (ENGLISH VERSION) WINDOWS VISTA (ENGLISH VERSION)WINDOWS 7 (ENGLISH VERSION)
IE8, IE7, FIREFOX 3.6 OR HIGHER
COMMUNICATION BETWEEN THE LCT AND THE IPASOLINK IS VIA THE LCT PORT OF IDU CONNECTED BY LAN CABLE.
10/100 Base-TX (RJ-45)
SET THE PC INTERNET PROTOCOL, TCP IP PROPERTIES TO “OBTAIN IP ADDRESS AUTOMATICALLY “ AND “OBTAIN DSN SERVER ADDRESS AUTOMATICALLY”
LCT Port supports DHCP Default IP address is 172.17.254.253
© PT. NEC Indonesia 2010 NEC ConfidentialPage 3
LCT Startup and LoginLCT Startup and Login
Start the browser Internet Explorer and enter the URL http://172.17.254.253/weblct/ to open the WebLCT Login screen.
Enter the “User Name” and “Password” in the provided text boxes and Click Ok button
Default Username : Admin
Password: 12345678
LCT main menu opens in the “Current Status screen”
© PT. NEC Indonesia 2010 NEC ConfidentialPage 4
WebLCT LOGOUTWebLCT LOGOUT
To Logout of the WebLCT, click on the Logout button on the top right hand of the LCT screen.
When Logout Confirm window appears, Click Yes
LCT Login window appears
Close the Browser window to exit WebLCT.
Always Logout using this button before disconnecting the cable.
© PT. NEC Indonesia 2010 NEC ConfidentialPage 5
WebLCT Initial ScreenWebLCT Initial ScreenLogin User Name
Indicate the current logged in user
Summary Alarm Indication
Indicate the summary alarm of ODU, IDU, AUX I/O, TCN, & Maintenance Status
Opposite Site Links
Connect
Maintenance
Maintenance ON/OFF button
Logout
Logout button
Menu tree
Indicate the LCT Main Menu
Block Diagram
Indicate the ODU, IDU and Interfaces
mounted
Detail Display
Display detail alarm & status information of items selected from the Tabs
© PT. NEC Indonesia 2010 NEC ConfidentialPage 6
Block DiagramBlock Diagram
Block Diagram of IDU with two ODUs connected and
STM-1 option
Block Diagram of IDU with one ODU connected and additional 16 X E1 option
Block Diagram of IDU with one ODU connected and additional 16 X E1 , AUX
and PS Input options
Block Diagram of IDU withone ODUs connected and
STM-1 option
© PT. NEC Indonesia 2010 NEC ConfidentialPage 7
Active Alarms & Event LogActive Alarms & Event Log
Click on the Active Alarm Tab to see details of current Alarms
Click on Save button to save the active alarm list to the PC
Click on Event Log tab to see the even Log information. Click save to save the event log to a CSV file
© PT. NEC Indonesia 2010 NEC ConfidentialPage 8
ODU & IDU Detail Alarm and StatusODU & IDU Detail Alarm and StatusClick on the ODU icon in the block diagram or the ODU tab to see the detail alarm and status information of the ODUs
Click on the IDU block diagram or the IDUtab to see the detail alarm and status information of the IDU and its mounted modules
© PT. NEC Indonesia 2010 NEC ConfidentialPage 9
WebLCT Main MenuWebLCT Main MenuMenus for Metering
Equipment UtilityUser Account / SecurityS/W License setup
Can be accessed by selecting the check box “Detail Menu”
Click the “Expand All” icon to expand all menu items and click “ Collapsed All” icon to collapse the menu items
© PT. NEC Indonesia 2010 NEC ConfidentialPage 10
Main MenuMain Menu
© PT. NEC Indonesia 2010 NEC ConfidentialPage 11
Provisioning MenuProvisioning Menu
Click the “+” to expand each main menu folder and see the sub-menu items
© PT. NEC Indonesia 2010 NEC ConfidentialPage 12
Maintenance MenuMaintenance Menu