DAB PUMPS reserve the right to make modifications without prior notice4®
JET
GENERAL DATA
ApplicationsSelf-priming centrifugal pump with excellent suction capacity even when there are air bubbles and smallparticles of sand in the water.Used especially for supplying water to domestic installations. Ideal for use in small-scale agriculture andgardening, limited industrial services and wherever self-priming operation is necessary.
Constructional features of the pumpCast iron pump body and motor support.Motor support in die-cast aluminium for Jet 62-82-102-112-92-132.Technopolymer impeller, diffuser, Venturi tube and sand guard.Stainless steel pressure discs.Carbon/ceramic mechanical seal.
Constructional features of the motorInduction motor, closed and cooled with external ventilation.Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life.Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phaseversion.Three-phase motors should be protected with a suitable overload protection complying with theregulations in force.Manufactured according to CEI 2-3 and CEI 61-69 standards (EN 60335-2-41).Motor protection: IP 44Terminal box protection: IP 55Insulation class: FStandard voltage: single-phase 220-240 V/50 Hz
three-phase 230-400 V/50 Hz
JET 200-300
JET 62-82-102-112-92-132 JET 151-251
DAB PUMPS reserve the right to make modifications without prior notice 5®
* In contact with the liquid.
TECHNICAL DATA
Self priming capacity
1 4 28 7
316160
- Operating range: from 0,4 to 10,5 m3/h with head up to 62 metres
- Liquid quality requirements: clean, free from solids or abrasive substances, non viscous,non aggressive, non crystallized, chemically neutral, close tothe characteristics of water.
- Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41)from 0°C to +40°C for other uses
- Maximum ambient temperature: +40°C
- Maximum operating pressure: 8 bar (800 kPa)
- Installation: fixed in a horizontal position
- Special executions on request: other voltages and/or frequencies
t (sec) Tempo di adescamento0 10 20 30 40 50 60 70 80 90 100
0 0
1
2
3
4
5
6
7
8
9
10
Hs(m
)Alte
zza
dias
piraz
ione
5
10
15
20
25
30
H(ft)
t (sec) Tempo di adescamento0 10 20 30 40 50 60 70 80 90 100
0 0
1
2
3
4
5
6
7
8
9
10
Hs(m
)Alte
zza
dias
piraz
ione
5
10
15
20
25
30
H(ft)
G 1DN 25
N.13
47
1628160
PARTS*PUMP BODYSUPPORT
IMPELLERSHAFT WITH ROTOR
MECHANICAL SEALOR GASKETNOZZLE-VENTURIDIFFUSER ASSEMBLY
MATERIALSCAST IRON 200 UNI ISO 185CAST IRON 200 UNI ISO 185DIE-CAST ALUMINIUMTECHNOPOLYMER ASTAINLESS STEEL AISI 416X12 CrS13 - UNI 6900/71CARBON/CERAMICNBR RUBBERTECHNOPOLYMER A
MODELS
JET 151; 251; 200; 300JET 62; 82; 102; 112; 92; 132
Hs(m
)Suc
tionhe
ight
t (sec) Priming time
Hs(m
)Suc
tionhe
ight
t (sec) Priming time
A
A1
C
H3
H
E FI
G
B
A
A1
C
H3
H
E FI
G
B
DAB PUMPS reserve the right to make modifications without prior notice6®
A
395
A1
390
B
178
C
108
E
192
F
14
G
111
H
193
H3
144
I
9
DNA
1” G
DNM
1” G
MODEL
JET 62 470 240 240
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,022
WEIGHTKg
10,5
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
0,72
0,67
0,44
0,44
0,6
0,6
3,12
2,1-1,2
12,5
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
42
Q00
35
Q0,610
29,2
Q1,220
25,6
Q1,830
22,9
Q2,440
21,1
Q2,745
–
Q3,660
MODEL
JET 62 M
JET 62 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2850 1/min)
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0 °C to +35°C
Maximum ambient temperature: +40°C
JET 62
Q m3/h0 0,5 1 1,5 2 2,5 30
10
20
30
40
0
20
40
60
80
100
120
0
0
0
Q l/s
Q l/min
Q IMP gpm
Q US gpm
0
0
0,2 0,4 0,6 0,8
10 20 30 40 50
Hm
Hft
PkPa
100
200
300
400
2 4 6 8 10 12
2 4 6 8 10
JET 62
8
6 5 4
2
Hs 9
7
3
A
395
A1
395
B
178
C
108
E
192
F
14
G
111
H
193
H3
144
I
9
DNA
1” G
DNM
1” G
MODEL
JET 82 470 240 240
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,022
WEIGHTKg
10,7
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
0,85
0,86
0,6
0,6
0,8
0,8
3,2
2,8-1,6
12,5
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
47
Q00
40
Q0,610
34
Q1,220
30
Q1,830
26,2
Q2,440
23,5
Q350
20,3
Q3,660
MODEL
JET 82 M
JET 82 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)
JET 82
Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40
10
20
30
40
50
0
20
40
60
80
100
120
160
0
0
0
Q l/s
Q l/min
Q IMP gpm
Q US gpm
0
0
0,2 0,4 0,6 0,8 1
10 20 30 40 50 60
Hm H
ft
PkPa
100
200
300
400
2 4 6 8 10 12 14 16
2 4 6 8 10 12 14
JET 82
Hs 9
8
5 43 2
7 6
A
A1
C
H3
H
E FI
G
B
A
A1
C
H3
H
E FI
G
B
DAB PUMPS reserve the right to make modifications without prior notice 7®
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0 °C to +35°C
Maximum ambient temperature: +40°C
JET 102
A
414
A1
409
B
178
C
108
E
197
F
14
G
111
H
203
H3
144
I
9
DNA
1” G
DNM
1” G
MODEL
JET 102 470 240 240
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,022
WEIGHTKg
12,5
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
1,13
1,04
0,75
0,75
1
1
5,1
3,3-1,9
16
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
53,8
Q00
47
Q0,610
41
Q1,220
36,3
Q1,830
32,4
Q2,440
28,8
Q350
25,8
Q3,660
MODEL
JET 102 M
JET 102 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2800 1/min)
Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40
10
20
30
40
50
0
20
40
60
80
100
120
160
0
0
0
Q l/s
Q l/min
Q IMP gpm
Q US gpm
0
0
0,2 0,4 0,6 0,8 1
10 20 30 40 50 60
Hm H
ft
PkPa
100
200
300
400
2 4 6 8 10 12 14 16
2 4 6 8 10 12 14
JETCOM 102
Hs 98
7
42
65
3
A
414
A1
409
B
178
C
108
E
192
F
14
G
111
H
203
H3
144
I
9
DNA
1” G
DNM
1” G
MODEL
JET 112 470 240 240
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,022
WEIGHTKg
13,5
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
1,4
1,35
1
1
1,36
1,36
6,2
4,3-2,5
25
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
61
Q00
54
Q0,610
47,8
Q1,220
42,8
Q1,830
38,8
Q2,440
34,8
Q350
20
Q3,660
MODEL
JET 112 M
JET 112 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)
JET 112
Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40 0
40
80
120
160
200
0
0
0
Q l/s
Q l/min
Q IMP gpm
Q US gpm
0
0
0,2 0,4 0,6 0,8 1
10 20 30 40 50 60
Hm H
ft
PkPa
10100
20200
30300
40400
50500
60600
2 4 6 8 10 12 14 16
2 4 6 8 10 12 14
JET 112
87
42
65
3
Hs 9
A
A1
C
H3
H
E FI
G
B
A
A1
C
H3
H
E FI
G
B
DAB PUMPS reserve the right to make modifications without prior notice8®
A
395
A1 B
390
C
178
E
108
F
192
G
14 111
H
193
H3
144
I
9
DNA
1” G
DNM
1” G
MODEL
JET 92 470 240 240
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,022
WEIGHTKg
11,7
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0 °C to +35°CMaximum ambient temperature: +40°C
JET 92
Q m3/h0 1 2 3 4 50 0
20
40
60
80
100
120
140
0
00
Q l/sQ l/min
Q IMP gpmQ US gpm
0
0
0,2 0,4 0,6 0,8 1 1,2 1,4
10 20 30 40 50 60 70 80 90
Hm
Hft
PkPa
10100
20200
30300
40400
2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20
Hs8
2
75 4
3
JET 92
9
6
A
414
B
409409
A1
263
C
108
E
192
F
14
G
111
H
203
H3
144
I
9
DNA
1” G
DNM
1” G
MODEL
JET 132 470 240 240
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,022
WEIGHTKg
13,5
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
1,49
1,43
1
1
1,36
1,36
6,6
4,7-2,7
25
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
48
Q00
45,6
Q0,610
42,8
Q1,220
40
Q1,830
37,6
Q2,440
35
Q350
32,5 30 27
Q3,660
Q4,270
Q4,880
MODEL
JET 132 M
JET 132 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
0,94
0,93
0,75
0,75
1
1
4,2
3,3-1,9
14
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
36,2
Q00
33,5
Q0,610
31
Q1,220
28,4
Q1,830
26
Q2,440
24
Q350
21,8 19,6 17
Q3,660
Q4,270
Q4,880
MODEL
JET 92 M
JET 92 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)
JET 132
Q m3/h0 1 2 3 4 50 0
20
40
60
80
100
120
140
0
00
Q l/sQ l/min
Q IMP gpmQ US gpm
0
0
0,2 0,4 0,6 0,8 1 1,2 1,4
10 20 30 40 50 60 70 80 90
Hm
Hft
PkPa
10100
20200
30300
40400
2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20
Hs8
6
2
7
54
3
JET 132
9
DAB PUMPS reserve the right to make modifications without prior notice 9®
A
558
B
210
C
221
E
350
F
20
G
145
I Ø
11
H
255
H1
158
DNA
11/4”G
DNM
1” G
MODEL
JET 151 612 248 279
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,042
WEIGHTKg
31
A
632
558
210
210
221
221
350
350
20
20
145
145
11
11
255
255
158
158
B C E F G I Ø H H1 DNA
11/4”G
11/4”G
DNM
1” G
1” G
MODEL
JET 251 M
JET 251 T
657
612
248
248
279
279
0,045
0,042
35
31
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
WEIGHTKg
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
1,6
1,6
1,1
1,1
1,5
1,5
7,2
5,2-3
31,5
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
61
Q00
58,2
Q0,610
56
Q1,220
53
Q1,830
50
Q2,440
46
Q350
43
Q3,660
39,5
Q4,270
36
Q4,575
MODEL
JET 151 M
JET 151 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2800 1/min)
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0 °C to +35°CMaximum ambient temperature: +40°C
JET 151
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
2,2
2,2
1,85
1,85
2,5
2,5
10
6,9-4
40
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
62
Q00
60
Q0,610
58
Q1,220
56
Q1,830
54
Q2,440
51
Q350
48,5
Q3,660
46
Q4,270
43,5
Q4,580
39
Q6100
34,2
Q7,2120
MODEL
JET 251 M
JET 251 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2800 1/min)
JET 251
Q m3/h0 1 2 3 4 5 6 7 8 90
10
20
30
40
50
60
0
40
80
120
160
200
0
00
Q l/sQ l/min
Q IMP gpmQ US gpm
0
0
0,5 1 1,5 2 2,5
20 40 60 80 100 120 140
Hm
Hft
PkPa
100
200
300
400
500
600
5 10 15 20 25 30 35 405 10 15 20 25 30
6
2
75
1
3
Hs 8
4
Q m3/h0 1 2 3 4 50
10
20
30
40
50
60
0
40
80
120
160
200
0
00
Q l/sQ l/min
Q IMP gpmQ US gpm
0
0
0,2 0,4 0,6 0,8 1 1,2 1,4
10 20 30 40 50 60 70 80 90
Hm
Hft
PkPa
100
200
300
400
500
600
2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20
Hs 86
2
7
5 4
1
3
DAB PUMPS reserve the right to make modifications without prior notice10®
A
521
B
214
C
151
E
282
F
20
G
160
I Ø
11
H
227
H1
175
DNA
11/2”G
DNM
11/4”G
MODEL
JET 200 612 248 279
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
0,042
WEIGHTKg
27
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
2,0
2,0
1,5
1,5
2
2
9
6,8-3,9
31,5
–
450
–
H(m)
P1MAXkW
InA
P2NOMINALkW HP
CAPACITOR
µF Vc
Qm3/hl/min
41
46,5
38
43,5
36,5
41,8
34
39,2
31,8
37
29,5
34,2
27,2
31,8
24
28
21,3
25
Q00
Q1,525
Q2,440
Q3,660
Q4,880
Q6100
Q7,2120
Q9150
Q10,5175
MODEL
JET 200 M
JET 200 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2850 1/min)
VOLTAGE50 Hz
1x220-240 V ∼
3x230-400 V ∼
2,7
2,5
2,2
2,2
3
3
12
8,5-4,9
40
–
450
–
H(m)
P1MAXkW
InA
P2NOMINAL
kW HP
CAPACITOR
µF Vc
Qm3/hl/min
51
Q00
49
Q1,525
48
Q1,830
47
Q2,440
44,5
Q3,660
42
Q4,880
40
Q6100
37
Q7,2120
33
Q9150
29
Q10,5175
MODEL
JET 300 M
JET 300 T
ELECTRICAL DATA HYDRAULIC DATA (n ~ 2850 1/min)
The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.
Liquid temperature range: from 0 °C to +35°CMaximum ambient temperature: +40°C
JET 200
A
595
521
214
214
151
151
282
282
20
20
160
160
11
11
235
227
175
175
B C E F G I Ø H H1 DNA
11/2”G
11/2”G
DNM
11/4”G
11/4”G
MODEL
JET 300 M
JET 300 T
657
612
248
248
279
279
0,045
0,042
31,5
27
PACKING DIMENSIONSL/A L/B H
VOLUMEm3
WEIGHTKg
JET 300
Q m3/h0 1 2 3 4 5 6 7 8 9 10 11 120
10
20
30
40
50
0
20
40
60
80
100
120
160
0
00
Q l/sQ l/min
Q IMP gpmQ US gpm
0
0
0,5 1 1,5 2 2,5 3
20 40 60 80 100 120 140 160 180 200
Hm
Hft
PkPa
100
200
300
400
5 10 15 20 25 30 35 40 45 505 10 15 20 25 30 35 40
Hs 86
3 2
75 4
1
top related