2 d r e a d e p d c r a g e · 2019-01-22 · sensor type 1.3 million pixel cmos sensor light...
Post on 01-Jun-2020
1 Views
Preview:
TRANSCRIPT
www.fluidx.co.uk
2D
R
ea
de
rs
P
ro
du
ct
R
an
ge
In
cl
ud
in
g
tu
be
l
ab
el
li
ng
a
nd
s
or
ti
ng
ve
rs
io
n
2.
0
Reader Overview Charts
Single tube readers 1
Whole rack readers 2
Single Tube Readers
XTR-SINGLE 3
XTR-1 PRO 4
XTR-1 ELITE 5
XTR-1 ELITE BT 6
Whole Rack Readers
Summary table 7
XTR-RACK (standard, with linear barcode, and cryo options) 8
XTR-RACK FLEX (standard, with linear barcode, and cryo options) 9
XTR-RACK LF (standard, with linear barcode, and cryo options) 11
Cryo option 12
Camera-Based Whole Rack Readers
XTR-RACK PRO 13
EasyTrack Software 15
Sample Storage Starter Packs 16
XTP-1152 Automated Tube Picker and Sorter 18
XTL-96 Microtube Labelling System 20
CONTENTS
PRODUCT XTR-SINGLE XTR-1 PRO XTR-1 ELITE XTR-1 ELITE BT
CATALOG NO 20-1001 20-1010 20-1003 20-1008
SCAN AND DECODE TIME (seconds) 1 1 1 1
DIMENSIONS (mm) 77 x 100 x 100 125x 100 x 95 61 x 167 x 41.2 65 x 196 x 47.5
KEYBOARD WEDGE P P P P
CONFIGURE OUTPUT TEXT P P P P
WINDSOCK CLIENT x P x x
WINDSOCK SERVER x P x x
TCP/IP REMOTE CONTROL x P x x
LINEAR SQL QUERY x P x x
LINEAR BARCODE x P P P
COMPATIBILITY All All All All
CABLE USB USB USB USB
EXTERNAL POWER x P x x
VIRTUAL RS232 COM PORT x x x P
1
Single Tube 2D Code Readers Overview
2D DATAMATRIX CODE READERS
2
Whole Rack 2D Code Readers Overview
PRODUCT XTR-RACK XTR-RACK FLEX XTR-RACK CRYO XTR-RACK LF CRYO XTR-RACK PRO
CATALOG NO 20-2002 20-2102 20-2105 20-2106 20-3101/ 20-3121
BASIC SPECIFICATIONS
IMAGING TECHNOLOGY CCD CCD CCD CCD CAMERA X8
DECODE TIME 2 SECS 2 SECS 2 SECS 2 SECS 1 SEC
SCAN TIME 8 SECS 8 SECS 8 SECS 15 SECS 1 SEC
DIMENSIONS (mm) 291 X 175 X 71 291 X 175 X 71 291 X 175 X 71 440 X 300 X 68 207 X 184 X 84
SOFTWARE COMPATIBILITY
WINDOWS XP P P P P P
WINDOWS 7 32 BIT P P P P X
WINDOWS 7 64 BIT P P P P X
CONNECTION USB X2 USB X2 USB X2 USB X1 CUSTOM
OUTPUT OPTIONS
OUTPUT TEXT FILE P P P P P
CONFIGURE OUTPUT FILE P P P P P
EXPORT TO EXCEL X P P P P
ODBC DATABASE PUSH X P P P P
USER ACCOUNT INDEPENDENT P P P P P
NETWORK READY X P P P P
TCP/IP REMOTE CONTROL X P P P P
DIRECT LINK TO EASYTRACK X P P P P
AUTORUN READ AND CLOSE
(DRIVELESS INTEGRATION)P P P P P
RACK AND TUBE COMPATIBILITY
24 RACK X P P P X
48 RACK P P P P X
96 RACK P P P P P
10X10 CRYO RACK X X X P X
384 RACK X P P P X
FULLY CUSTOMISABLE RACK FORMAT X P P P P
READ ALL DATAMATRIX CODES P P P P P
REMP COMPATIBLE X P* P* P* P
AUTO RACK ORIENTATION X P P P P
OTHER FEATURES
NO TUBE FEATURE X P P P P
SINGLE TUBE READING X P P P X
RACK TEMPLATES X P P P X
ANTI-FROST SYSTEM X X P P P
ROBOT GRIPPER FRIENDLY P P P P P
OPTIONAL LINEAR BARCODE READER X P P P P
2D RACK ID X P P P X
* Please contact FluidX for additional information
2D DATAMATRIX CODE READERS
Code formats Datamatrix, ISO 16022, square and rectangular format,
ECC200, 0 to 20 grid sizes, white on black, black on
white, numeric and alphanumeric
Sensor type 1/3” CCD
Light source R LED
Read time Less than 1 second per tube
Ambient operating
temperature
5 to 50°C
Tube compatibility All tubes in 24, 48, 96, 240 and 384-formats.
Glass compound storage tubes, cryo tubes, biological
sample tubes
Dimensions H 77 X W 100 X D 100mm
Weight 0.25 Kg
Power requirements 5V DC 0.1A max. supplied through USB
User interface FluidX GUI
Cable length 1.5m
Cable interface USB 2.0
Operating system Windows XPTM and Windows 7TM 32 and 64 bit
Specifications
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk3
SINGLE TUBE 2D CODE READERS
XTR-SINGLE standard single tube reader
Decode all 2D-coded tubes
FluidX single tube readers are compatible with tubes provided by
all major manufactures in 24, 48, 96, 240 and 384 rack formats.
Also suitable for use with larger capacity tubes including glass
compound storage tubes, cryo tubes and biological sample
tubes.
Auto learning setup for quick and easy changing between tube
types.
Fast
All our single tube readers take less than 1 second to scan and
decode.
The XTR- SINGLE is quick and simple to install.
Flexible data capture
Tube data can be sent to any application via keyboard wedge
interface.
Dependable decoding
All FluidX readers use the same industry leading decoding
algorithm.
Large window and scan area.
Tube ID displayed instantly on computer screen for identification
or sample entry or application can run in the background.
Ordering Information
Catalog No Description
20-1001 XTR-SINGLE single tube reader for all 2D Datamatrix coded tubes.
XTR-1 PRO single tube reader with built-in display
Code formats Datamatrix, ISO 16022, square and rectangular
format, ECC200, 0 to 20 grid sizes, white on black,
black on white, numeric and alphanumeric
Sensor type 1/3” CCD
Light source R LED
Read time Less than 1 second per tube
Tube compatibility All tubes in 24, 48, 96, 240 and 384-formats.
Glass compund storage tubes, cryo tubes, biological
sample tubes
Dimensions Width125mm x depth 100mm x height 95mm
Weight 0.25 Kg
Power requirements External 12V power source
User interface FluidX GUI, realtime video image, including WindowsTM
TCP/IP, ODBC
Cable interface USB 2.0
Ambient operating
temperature
5 to 50°C
Operating humidity
(non-condensing)
10 to 90%
Operating system Windows XPTM and Windows 7TM (32 bit only)
Specifications
Decode any 2D-coded tube
FluidX single tube readers are compatible with tubes provided by all
major manufactures in 24, 48, 96, 240 and 384 rack formats.
Also suitable for use with larger capacity tubes including glass
compound storage tubes, cryo tubes and biological sample tubes.
Auto learning setup for quick and easy changing between tube
types.
Fast
All single tube readers take less than 1 second to scan and decode.
Flexible data capture
All FluidX single tube readers are easy to use with a wide variety of
data capture options.
Tube data can be sent to any application and linked to a spread-
sheet or database (including ExcelTM).
The FluidX unique “smart-wedge” ensures the data goes exactly
where you want.
Tube data and SQL database query results are displayed on the
reader to provide immediate confirmation of the sample name,
volume or additional details obtained directly from database, with
full support for SQL queries.
Data can also be sent to any application and linked to a spread-
sheet or database.
1GB internal storage option is available for back-up and/or
installation CD.
Reader can be moved between computers.
Dependable decoding
All FluidX readers use the same industry leading decoding
algorithm.
SINGLE TUBE 2D CODE READERS
Ordering Information
Catalog No Description
20-1010 XTR-1Pro
Single tube reader for all 2D Data-Matrix labelled tubes with build in
display and SQL Database query function.
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk4
46.75
63
61.1
19.3
1.3
17.3
536
.7
2.25
92
124
94
68.8
98.8
35.2
5
62
1.75
Ǿ16
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk5
XTR-1 ELITE The easiest to use single tube reader now comes with enhanced performance
SINGLE TUBE 2D CODE READERS
Code formats Data Matrix®, ISO 16022, Square and
Rectangular Format, ECC 200, 0 - 20grid sizes,
White on Black and Black on White, Numeric
and Alphanumeric
Sensor type 1.3 million pixel CMOS sensor
Light source Class 2M Visible Laser Diode at 630nm
Read time Less than 1 second per tube
Tube compatibility All tubes in 24, 48, 96, 240 and 384-formats.
Glass compund storage tubes, cryo tubes,
biological sample tubes
Dimensions Width 61mm x depth 167mm x height 41.2mm
Weight 0.3Kg
Power requirements USB hub (5V)
User interface Keyboard wedge
Cable interface USB
Ambient operating
temperature
5 - 50°C
Operating humidity
(non-condensing)
5 - 95%
Operating system Windows XPTM and Windows 7TM , Windows CE,
MAC OSX, Linux
Specifications
The XTR-1ELITE remains the easiest to use single tube 2D-code
reader available. Simply plug into a USB port and it will be ready to
read within 5 seconds!
No software installation or CPU usage. Can be used with any PC
and all versions of WindowsTM operating systems.
The XTR-1ELITE will send the decoded tube ID to any open
application (where the cursor is placed).
Decode all 2D-coded tubes
FluidX single tube readers are compatible with tubes provided by all
major manufactures in 24, 48, 96, 240 and 384 rack formats.
Also suitable for use with larger capacity tubes including glass
compound storage tubes, cryo tubes and biological sample tubes.
Auto learning setup for quick and easy changing between tube
types.
Fast
All single tube readers take less than 1 second to scan and decode.
Flexible data capture
Tube data can be sent to any application.
Dependable decoding
All FluidX readers use the same industry leading decoding
algorithm.
Ordering Information
Catalog No Description
20-1003 XTR-1Elite
Single tube reader for all 2D Data-Matrix labelled tubes, hardware
decoding with USB connection and keyboard wedge.
167
118.6
30.5
6141
.2
38.5
2
16
25.4
13.3
Ǿ20
21.8
XTR-1 ELITE BT easiest to use single tube reader with enhanced performance
The easiest to use single tube 2D code reader available is now
mobile. With the addition of Bluetooth the XTR-ELITE BT can identify
samples anywhere, anytime, particularly useful for reading codes
in remote locations.
Overcome the traditional issues of partial bluetoothTM connections
by using unique bluetooth air cable.
Decode all 2D-coded tubes
FluidX single tube readers are compatible with tubes provided by
all major manufactures in 24, 48, 96, 240 and 384 rack formats.
Also suitable for use with larger capacity tubes including glass
compound storage tubes, cryo tubes and biological sample
tubes.
Auto learning setup for quick and easy changing between tube
types.
Fast
All single tube readers take less than 1 second to scan and
decode.
Flexible data capture
All FluidX single tube readers are easy to use with a wide variety of
data capture options.
Tube data can be sent to any application and linked to a spread-
sheet or database (including ExceTM l).
The FluidX unique “smart-wedge” ensures the data goes exactly
where you want.
Simple to integrate
ODBC connectivity allows database integration.
Winsock connectivity provides instantrobotic integration.
Dependable decoding
All FluidX readers use the same industry leading decoding
algorithm.
Sample identification is almost instantaneous. Simply turn on to
scan the tube and the tube ID is inserted into Windows ExcelTM on
the PDA.
Further data can be added manually.
Excel spreadsheet synchronises with PC when docked.
No software installation or CPU usage.
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk
SINGLE TUBE 2D CODE READERS
Code formats Data Matrix®, ISO 16022, Square and Rectangular
Format, ECC 200, 0 - 20grid sizes, White on Black
and Black on White, Numeric and Alphanumeric
Sensor type 1.3 million pixel CMOS sensor
Light source Class 2M Visible Laser Diode at 630nm
Read time Less than 1 second per tube
Tube compatibility All tubes in 24, 48, 96, 240 and 384-formats.
Glass compound storage tubes, cryo tubes,
biological sample tubes.
Dimensions Width 65mm x depth 196mm x height 47.5mm
Weight 0.4Kg
Power requirements USB hub (5V)
User interface Keyboard wedge
Cable interface USB
Virtual com port Virtual com prt RS232/BT
Ambient operating
temperature
5 - 50°C
Operating humidity
(non-condensing)
5 - 95%
Operating system Windows XPTM and Windows 7TM , Windows CETM ,
MAC OSX, Linux
Specifications
Ordering Information
Catalog No Description
20-1005 XTR-1Elite BT HP PDA
Bluetooth and Battery enabled Single tube reader for all 2D Data-Matrix
labelled tubes, hardware decoding with HP iPAQ 214 PDA
20-1006 XTR-1Elite BT PC
Bluetooth and Battery enabled Single tube reader for all 2D Data-Matrix
labelled tubes, hardware decoding with Bluetooth USB Modem, no drivers
or software required.
20-1007 XTR-1Elite BT PC & PDA
Bluetooth and Battery enabled Single tube reader for all 2D Data-Matrix
labelled tubes, hardware decoding with Bluetooth USB Modem, no drivers
or software required and HP iPAQ 214 PDA.
20-1008 XTR-1Elite BT Modem
Bluetooth USB Modem, no drivers or software required for use with
XTR-1Elite BT Edition.
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk6
196
23
68
34
22.5
28.15
44 47.5
Ǿ12
.15
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk
WHOLE RACK 2D CODE READERS introduction
Standard Version Integrated Linear
Barcode Option
Cryo Model
(Integrated Frost
Reduction System)
Cryo Model
With Integrated Linear
Barcode Reader
XTR-RACK Cat No 20-2002 Not available Cat No 20-2003 Not available
XTR-RACK FLEX Cat No 20-2102 Cat No 20-2103 Cat No 20-2105 Cat No 20-2107
XTR-RACK LF Not available Not available Cat No 20-2106 Not available
7
The XTR-RACK range of whole rack 2D code readers is made up of three
standard models, the XTR-RACK, XTR-RACK FLEX and XTR-RACK LF.
In addition, the XTR-RACK PRO readers are designed to meet high
throughput needs.
The XTR-RACK, XTR-RACK FLEX and XTR-RACK LF readers use CCD
imaging and sophisticated decoding methods to provide robust sample
identification in just 10 seconds (total scan and decode time).
OPTIONS
A choice of additional options are available with these models (see
table below). These include an integrated linear barcode reader and
cryo version which features and integrated frost reduction system that
enables multiple racks to be read straight from freezer without the
reliability issues that can arise due to the presence of frost or
condensation.
The XTR-RACK PRO high speed whole rack readers can be easily
integrated into automated systems, with a total scan and decode
time of just 2 seconds for a rack of 96 or 384 tubes.
With frost reduction system Without frost reduction system
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk8
XTR-RACK benchtop whole rack reader for SBS format racked tubes
WHOLE RACK 2D CODE READERS
Code formats Data Matrix®, ISO 16022, Square and Rectangular
Format, ECC 200, 0 - 20grid sizes, White on Black and
Black on White, Numeric and Alphanumeric
Sensor type Colour CIS (contact image sensor)
Light source R, G, B LED (variable light source)
Read time Less than 9 seconds per rack
Tube compatibility All tubes in 24, 48 and 96-formats. Glass compound
storage tubes, cryo tubes, biological sample tubes
Dimensions Width 51mm x depth 256mm x height 154mm
Power
requirements
AC 100 -240 V +/-10%. Less than 8W
User interface FluidX GUI, including WindowsTM TCP/IP, ODBC
Cable interface USB 2.0/ USB 1.1, USB type B
Operating system Windows XPTM and Windows 7TM
SpecificationsCompatible with all SBS format racks (24, 48, 96, 240, 384 tubes
per rack)*
Fast and compact
Based on a super-fast A5 high definition scanner that takes less
than eight seconds to scan and decode a full rack of 96 tubes.
Easy to use
Simple intuitive interface enables single button scan, decode
and export of results to a wide range of other applications.
Simple to integrate
Driverless remote use makes integration simplicity itself. Simply
call the application to open, run, export and close.
World-class de-coding
All fluidx rack scanners use the same industry leading decoding
algorithm to provide the fastest, most robust decoding
available.
Read racks straight from freezer
Cryo option available with integrated frost reduction system for
use with low temperature storage tubes, see page12 for further
details.
*System supplied with 96 format racks enabled, additional racks can be
added as a cost option.
Ordering Information
Catalog No Description
20-2002 XTR-RACK
Small Form Factor Whole rack reader for racks of 96 2D-labelled
tubes. Fast reading on the bench top use.
20-2003 XTR-RACK CRYO
Small Form Factor Whole rack reader for racks of 96 2D-labelled
tubes. Fast reading on the bench top use.
With integrated frost reduction system.
Fast and reliable
12 second total scan and decode time for rack of 96 tubes. Quick
warm-up time. Excellent image quality and depth of focus.
Compatible with all 2D barcoded tubes in 24, 48, 96 and 384
racked format.
Also suitable for use with larger tubes such as glass compound
storage tubes, cryo tubes and biological sample tubes.
Easy to use with a wide variety of data capture options
Simple and intuitive Graphical User Interface. Results can be
viewed directly or integrated with other applications, ODBC
connectivity for database integration.
Direct data output to ExcelTM.
Automatic Rack Orientation, More Secure Tracking
FluidX racks are now supplied with a unique 2D Data Matrix code
identifier. This code can be read simultaneously when usingthe
XTR-RACK FLEX to provide automatic rack orientation and more
secure sample tracking.
“No tube” feature
Able to discriminate between tube with a barcode that cannot be
decoded and a rack position with no tube.
Will not attempt to decode empty tube positions and data files are
kept “clean” , wasted data entry is avoided leading to faster rack
reading.
Rack templates
User able to set up rack templates for applications where partially
filled racks are routinely decoded, leading to faster decoding time,
eliminates unwanted data.
Simple to integrate
ODBC connectivity allows database integration.
Winsock connectivity provides instant integration.
Only one USB connection is required for both power and data.
Dependable decoding
All FluidX readers use the same industry leading decoding
algorithm.
Single tube reading
Can be a pre-set location or a user-defined position within the rack.
When activated the system will decode a single tube within 8
seconds and display ID on screen, the ID can be copied to any
application with a single click.
Read 2D codes straight from freezer
CRYO version available with integrated frost reduction system for
use with low temperature storage tubes, further details on page 12.
Integrated linear bar code reader option
See ordering details on next page.
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk9
XTR-RACK FLEX a “next generation” rapid whole rack reader for desktop use with improved image quality
WHOLE RACK 2D CODE READERS
Code formats Data Matrix®, ISO 16022, Square and Rectangular Format, ECC 200, 0 - 20grid sizes,
White on Black and Black on White, Numeric and Alphanumeric
Sensor type CCD image sensor
Light source CCFL (cold cathode fluorescent light source)
Read time 12 seconds total scan and decode time for rack of 96 tubes
Tube compatibility All tubes in 24, 48, 96 and 384-formats.
Glass compound storage tubes, cryo tubes, biological sample tubes
Dimensions Width 175mm x depth 291mm x height 71mm
Weight 0.5kg
Power requirements AC 100 -240 V +/-10%. Less than 8W
User interface FluidX GUI, including Windows TCP/IP, ODBC
Cable interface USB 2.0/ USB 1.1, USB type B
Operating system Windows XPTM and Windows 7TM
Specifications
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk
XTR-RACK FLEX a “next generation” rapid whole rack reader for desktop use with improved image quality
WHOLE RACK 2D CODE READERS
Ordering Information
Catalog No Description
20-2102 XTR-RACK FLEX
Small Form Factor Whole rack reader for racks of 48 / 96 2D labelled tubes; small-footprint scanner based solution
for rapid reading and integration. Suitable for all tube types.
20-2103 XTR-RACK FLEX BC
Small Form Factor Whole rack reader for racks of 48 / 96 2D labelled tubes; small-footprint scanner based solution
for rapid reading and integration. With Integrated Linear Barcode Reader for barcodes located on the A1-H1 side.
Suitable for all tube types.
20-2105 XTR-RACK FLEX CRYO
Small Form Factor Whole rack reader for racks of 48 / 96 2D labelled tubes; small-footprint scanner based solution
for rapid reading and integration. With Integrated frost reduction. Suitable for all tube types.
20-2107 XTR-RACK FLEX CRYO BC
Small Form Factor Whole rack reader for racks of 48 / 96 2D labelled tubes; small-footprint scanner based solution
for rapid reading and integration. With Integrated frost reduction. With Integrated Linear Barcode Reader for
barcodes located on the A1-H1 side. Suitable for all tube types.
290.75
175
70.50
75.5
35.5
40
71
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk11
WHOLE RACK 2D CODE READERS
XTR-RACK LF whole rack reader compatible with traditional format racked cryotubes AND SBS format racked tubes
The first scanner designed for use with both traditional cryo format
and SBS format racks.
Ideal for use with cryogenic storage racks in 10x10 and 9x9
(133mmx133mm) formats.
Can also be used with SBS format racks and 5x5 cryogenic storage
racks by using an optional spacer.
Easy to use
Results can be viewed directly or integrated with other applications.
Direct data output to Excel.
Easily integrated
Winsock connectivity enables instant robotic integration and
automatic rack orientation.
“No tube” feature
Able to discriminate between tube with a barcode that cannot be
decoded and a rack position with no tube.
Will not attempt to decode empty tube positions and data files are
kept “clean” , wasted data entry is avoided leading to faster rack
reading.
Rack templates
User able to set up rack templates for applications where partially
filled racks are routinely decoded, leading to faster decoding time,
eliminates unwanted data.
Dependable decoding
All FluidX readers use the same industry leading decoding algorithm.
Simple to integrate
ODBC connectivity allows database integration.
Winsock connectivity provides instant integration.
Only one USB connection is required for both power and data.
Read 2D Datamatrix codes straight from the freezer
Currently available in CRYO version only. This rapid whole rack reader
retains all the features and benefits of the original XTR-96 FLEXI (CRYO)
on which it is based. Includes the integrated frost reduction system
which allows multiple racks to be read without build-up of frost or
condensation on the underside of the glass.
Code formats Data Matrix®, ISO 16022, Square and Rectan-
gular Format, ECC 200, 0 - 20grid sizes, White
on Black and Black on White, Numeric and Al-
phanumeric
Sensor type CCD image sensor
Light source CCFL (cold cathode fluorescent light source)
Read time 12 seconds total scan and decode time for rack
of 96 tubes
Tube compatibility All common 2D coded cryo tubes in 10x10 and
9x9 format racks (provided there is an open base
for viewing the tube).
Weight 0.6kg
Power requirements AC 100 -240 V +/-10%. Less than 8W
User interface FluidX GUI, including Windows TCP/IP, ODBC
Cable interface USB 2.0/ USB 1.1, USB type B
Operating system Windows XPTM and Windows 7TM
Specifications
Ordering Information
Catalog No Description
20-2106 XTR-RACK LF CRYO
Large Form Factor Whole rack reader for racks of square cryo racks
with 2D labelled tubes; includes 2 reading positions, one for 10x10 or
9x9 square racks and a second for 5x5 square racks.
Coming soon.... XTR-RACK TETRA FLEX
The XTR-RACK TETRA FLEX is fitted with four linear barcode readers, making it the only
Multi-Rack Reader able to tell you where each rack was placed!
Compatible with all SBS format 2D coded tubes.
“No tube” feature, able to discriminate between tube with a barcode that cannot be
decoded and a rack position with no tube.
User templates for applications where partially filled racks are routinely decoded.
CRYO version allows multiple racks to be read straight from freezer without build-up of frost
or condensation on the underside of the glass. Visit www.fluidx.eu for more info....
WHOLE RACK 2D CODE READERS
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk12
N0.
of
rac
ks
rea
d b
efo
re r
ea
din
g iss
ue
s a
rose
>40
racks
21
XTR-RACK CRYO NON FLUIDX READER
Standard XTR-RACK after reading
two cryo tubes stored at -80oC
XTR-RACK CRYO after reading
two cryo tubes stored at -80oC
new image
Readers tested with tubes stored at -80oC
CRYO MODELS more about the integrated frost reduction system
The storage of biological samples such as DNA, protein, blood
fractions and viable cells is becoming commonplace and the need
to store them at lower temperatures (e.g. -20ºC, -80ºC and Gas
Phase Liquid Nitrogen) has resulted in reading challenges for
traditional rack readers.
FluidX have developed rack readers capable of reading multiple
rackswithout the build-up of frost or condensation on the underside
of the glass which causes the code to become unreadable.
Standard FluidX racks readers will operate in a cold environment as
low as -20ºC and decoding the occasional rack of cryo tubes
should not be considered an issue due to the quick read time.
However, when scanning multiple racks the accumulated time the
cold racks spend in contact with the reader glass causes a drop
the air temperature on the underside of the glass.
Condensation and frost can appear which results in poor reading
capability and possible damage to the scanning head.
FluidX 2D-coded tubes adhere to ECC200 standards and our
readers employ superior decoding algorithms, however unreliable
reading can occur as the condensation builds up as the code is
obscured and the contrast between the code and the back-
ground is diminished.
The XTR-RACK CRYO achieves 100% decoding after reading more than 40 racks from a -20ºC freezer.
Tube image before frosting
of glass surface image
Tube image after frosting of
glass surface
Decoding frosted tubes
“The new Xtr-96 with anti misting scanning window has allowed us
to batch scan multiple -80 frozen racks, unlike the previous model
which required scanning to be interrupted by application of a
heat block to the scanning window every few racks. The ease and
trouble free use has resulted in stock control and quality control
being a stress free experience.”
Kaetan Ladhani, CJD Resource Centre, NIBSC.
Standard XTR-RACK v XTR-RACK CRYO model
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk13
XTR-RACK PRO high speed whole rack reader, ideal for robotic integration
WHOLE RACK 2D CODE READERS
High speed whole rack readers, ideal for robotic integration.
Compatible with 24, 48, 96 or 384-format racked 2D-coded tubes.
Fast
4 seconds total scan and decode time. 8 CCD cameras enable a
near instant read.
Easy to use with a wide variety of data capture options.
Simple, intuitive Graphical User Interface, results can be viewed
directly or integrated with other applications. ODBC connectivity for
database integration. Direct data output to ExcelTM .
Easily integrated
Winsock connectivity for instant robotic integration.
Automatic rack read and orientation
Simply place the rack on the reader and the XTR-RACK PRO will
read automatically using in-built sensors to determine rack
placement.
Robust
Sealed reading head is IP65 rated. Resistant to water, dust and
gases.
The XTR-RACK PRO is suitable for use at low temperatures (-20oC).
Dependable decoding
All FluidX readers use the same industry leading decoding
algorithm.
Simple to integrate
ODBC connectivity allows database integration.
Winsock connectivity provides instant integration.
Only one USB connection is required for both power and data.
No tube feature
Able to discriminate between a tube with a barcode that cannot
be decoded and a rack position with no tube.
The system will not attempt to decode empty tube positions and
data files are kept “clean” as wasted data entry is avoided,
leading to faster rack reading.
Optional integrated linear barcode reader.
XTR-RACK PRO
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk14
WHOLE RACK 2D CODE READERS
XTR-RACK PRO high speed whole rack reader, ideal for robotic integration
Ordering Information
Catalog No Description
20-3101 XTR-RACK PRO (96)
Whole rack reader for racks of 24, 48 and 96 2D labelled tubes;
small-footprint camera based solution for very rapid reading and ideal
for integration.
Requires a PC running Windows XP and a Spare PC Card slot.
20-3121 XTR-RACK PRO (384)
Whole rack reader for racks of 24, 48, 96 and 384 2D labelled tubes;
camera based solution for very rapid reading and ideal for integration
Code formats Data Matrix®, ISO 16022, Square and
Rectangular Format, ECC 200, 0 - 20grid
sizes, White on Black and Black on White,
Numeric and Alphanumeric
Sensor type 8x1.3 million pixel CMSO
Light source LED
Read time 4 seconds
Tube compatibility All tubes in 24, 48, 96 and 384-formats.
Glass compound storage tubes, cryo tubes,
biological sample tubes
Dimensions Length: 20.7cm X Width: 18.4cm X
Height: 8.4cm
Weight 2Kg
Power Input: 100-240Vac
Output: 12V dc, 5.0A, (60W)
Operating voltage and current: Up to 12V,
0.41A
User interface GUI
Ambient operating
temperature
-20 to 50°C
Operating humidity
(non-condensing)
10-90%
Operating system Windows XPTM and Windows 7TM
Specifications
Dimensions for XTR-RACK PRO
39.7 128 32.3
21.7
14.7
255
168
217
200
24.7
120
21.5
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk15
EASYTRACK SOFTWARE
FluidX EasyTrack software is a graphical sample archiving package
for sample management.
Provides the ability to confirm sample ID, search and retrieve
samples, archive, re-array and cherry pick samples.
Easy to use and ideal for small and medium sized laboratories.
Choose one of three versions; EasyTrack Lite, EasyTrack Single, or
EasyTrack Multi.
Developed and tested for use in most applications including molec-
ular biology, cell biology, virology, microbiology, biochemistry and
chemistry.
Flexible, with the ability to handle 2D sample codes. Access can be
tailored to enable different groups to use the same software.
Suitable for storing and tracking both linear and 2D-coded samples,
even complete boxes of tubes can be processed.
The storage environment can be customised by the user to meet
specific requirements.
EasyTrack Lite EasyTrack Single EasyTrack Multi
Cat. No. 20-9001 20-9002 20-9003
License type Single Single Install, Multi User
including Multi Divisions
12 Concurrent Users across
LAN, Shared data, including
Multi Divisions
Features
To insert a single new sample Yes Yes Yes
To insert multiple samples belonging to a
scanned rack
Yes with Import from
EasyTrack rack readers
Yes with direct EasyTrack rack
reader control and import
Yes with direct EasyTrack rack
reader control and import
To make search using various criteria:
sample ID, box ID or name
Yes, including user
defined fields
Yes, full Boolean Logic search Yes, full Boolean Logic search
To create a child rack from an existing
sample rack (or box)
No Yes Yes
To join different samples No Yes Yes
To delete samples Yes Yes both delete and remove Yes both delete and remove
To reorganize racks (or box) No Yes Yes
To import data from an external Excel file No Yes Yes
To organize the samples into the
containers (e.g. freezers)
Yes Yes Yes
To display the rack contents and insert it
into a container
Yes Yes Yes
To define different models of containers Yes Yes Yes
To view the report on racks being
processed and those already processed
No Yes Yes
To define and print labels with both linear
and 2D barcode
No Yes Yes
To define fields’ names; to create groups;
to access the available utilities
Yes Yes with pre defined
values and attach files to
samples
Yes with pre defined
values and attach files to
samples
To create a new user or to modify an
existing one.
Yes Yes with the ability to
create different access levels
to perform different functions
and separate divisions
Yes with the ability to
create different access levels
to perform different functions
and separate divisions
To exit the program Yes Yes Yes
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk16
STARTER PACKS
FluidX starter packs offer a one-stop solution for laboratories that want
to implement a secure sample storage system at a competitive price.
FluidX offer a number of packages that include a wide choice of
tubes, caps, 2D-code readers and manual decappers to suit most
applications and budgets.
Tailored packages can also be created on request.
Typical starter pack includes:
XTR-1ELITE single tube reader for all 2D-Datamatrix
labelled tubes.
40 racks of 96-format 2D-coded tubes, either
standard or with protective jacket, or
1000 precapped cryo tubes.
Piercable TPE septum seals or screw caps.
Manual tube decapper.
Manual single tube picker.
Deluxe packages also contain an XTR-RACK
benchtop whole rack reader for 2D-coded tubes
or XTR-RACK CRYO whole rack reader with frost
reduction for use with cryo tubes.
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk
STARTER PACKS
BASIC
STARTER
PACK A1
(Cat No
21-1001)
BASIC
STARTER
PACK A2
(Cat No
21-1101)
BASIC
STARTER
PACK B1
(Cat No
21-1002)
BASIC
STARTER
PACK B2
(Cat No
21-1102)
BASIC
STARTER
PACK C1
(Cat No
21-1003)
DELUXE
STARTER
PACK A1
(Cat No
21-1011)
DELUXE
STARTER
PACK A2
(Cat No
21-1111)
DELUXE
STARTER
PACK B1
(Cat No
21-1012)
DELUXE
STARTER
PACK B2
(Cat No
21-1112)
DELUXE
STARTER
PACK C1
(Cat No
21-1013)
XTR-1 ELITE
Single tube reader
(20-1003)P P P P P P P P P P
XTR-RACK
Whole rack 2D tube
reader.
(20-2002)
P P P PP
(cryo model)
STANDARD 2D-CODED
TUBES 40 racks
0.5ml, 1.0ml or 1.4ml.
96 tubes/rack.
(66-xxxxx)
P P P P
2D-CODED TUBES WITH
JACKET 40 racks
0.75ml, or 1.4ml.
96 tubes/rack.
(67-xxxxx)
P P P P
2D-CODED CRYO TUBES
1000 tubes, precapped.
2ml or 4ml, internal or
external thread.
(65-xxxxx)
P P
PIERCABLE SEPTUM SEAL
Natural on backing
plate of 96 caps.
50 mats/case.
(65-73000)
P P P P
SCREW CAPS
Orange 100/bag.
(65-53107)P P P P
MANUAL TUBE
DECAPPER
For single tubes.
(65-54000)
P P P P
MANUAL TUBE
DECAPPER
For 8 tubes.
(65-54001)
P P P P
MANUAL TUBE
DECAPPER
For single cryo tubes.
(65-54003)
P P
SCREW CAP REMOVER
(54-54004) P P P P
XTP-1 COMPACT
Manual tube picker
(10-51001)P P P P P P P P
48-WAY DISPOSABLE
RACKS
with open bottom
(65-754x)
P
FluidX starter packs offer a one-stop solution for laboratories that want to implement a secure sample storage system at a competitive price.
A number of packages that include a wide choice of tubes, caps, 2D-code readers and manual decappers to suit most applications and
budgets.
Tailored packages can also be created on request.
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk18
XTP-1152 Automated Tube Picker and Sorter
Unique tube picking, with integrated 2D code reader, weigh
station, decapper AND liquid handling.
The XTP-1152 represents a unique combination for rapid picking
and processing of all common types of microtube including 0.5,
0.65, 0.75 and 1.4ml tubes (with or without 2D datamatrix coding).
Capable of tube picking, 2D reading, tube weighing, and liquid
handling using either a single fixed or disposable tip system. This
combined functionality provides an independent and stand-alone
picking and processing centre.
Tube picking and sample processing
Integral liquid handling capability. The XTP-1152 is capable of cherry
picking, dilution, reagent addition and sample transfer functions
can be integrated into a single tube picking protocol.
12 rack (or plate) capacity with "quick-change" racks so that high
throughput demands can be easily met.
2D-code reading
Integrated linear barcode and 2D-datamatrix reading for positive
tube identification.
Sample weighing
Analytical grade balance provides tare weights, determines liquid
compound volume or dry compound weight.
Decapping
A decapping / capping module enables liquid handling steps to
be completed, even with a wide variety of screw-cap tubes and
cryovials.
The XTP-1152 can perform septum piercing with fixed probe and is
suitable for use with most split septum caps.
Pipette volume 1.0ul to 1000ul (fixed or disposable tip)
Precision < 5% CV at 1ul typical
< 1% CV at 5ul typical
Accuracy
(liquid to liquid transfer)
+/- 5% at 1ul typical
+/- 1% at 5ul typical
Resolution 1ul (96 offset)
Configurable deck 12 standard SBS footprint positions or equivalent
tube racks
3 reagent reservoirs
Wash/reagent
2D bar-coded tube read position
Tube weigh station position
Screw-cap un-capping/capping station
Bar code reading Capable of reading standard linear bar-codes on all
micro-plates and tube racks
Capable of reading Data-matrix codes on the base of
all 96 tube format tubes (FluidX Xtr-1 data-matrix
reader and software)
Tube picking capability Any standard 0.5ml, 0.6ml, 0.75ml, 1.4ml 96 tubes in
SBS format racks
format tubes.
Cryo-vials
Any other tube up to 75mm in height and 12mm
diameter.
2D data-matrix reader Capable of reading most tubes from major suppliers
and those that conform to ECC200.
Weigh station 4 position balance to 0.0001g
Un-capping station Capable of uncapping screw-cap tubes from Matrix,
Abgene, Micronic, Nunc
PC requirements Windows XP / 2000
Picking throughput Picking only; 900 tubes/ hour
Picking with reading; 700 tubes/ hour
Picking with weighing; 300 tubes/ hour
Picking plus reading and weighing; 200 tubes/ hour
Dimensions Length 950mm, Height 520mm, Width 550mm
Weight 50kg.
Power requirement 50/60Hz, 100v - 240v
Specifications
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk19
XTP-1152 Automated Tube Picker and Sorter (cont)
The XTP-1152 has the capacity to hold twelve 1.4ml tube racks, a small
footprint and the ability to handle large workloads, and includes the
following modules:
XYZ arm
The main arm carries the single channel sample processing unit, tube
gripper and linear bar-code reader.
Sample processing unit
The sample processing module consists of a precision 1.0ml syringe
and drive mechanism (volume range 1.0ul to 1000ul) which can be
linked to either a Teflon coated stainless steel probe or a tip nozzle
capable of accepting 250ul or 1000ul disposable tips.
Tube gripper
Capable of picking all standard 0.5ml, 0.6ml, 0.75ml and 1.4ml tubes
and cryo-vials. When used with the uncapping station, the tube
gripper is also able to uncap screw caps to allow access by standard
liquid handling tips.
Linear bar-code reader
For racks and micro-plate identification, suitable for use with most
racks and plate types.
Software incorporates “smart positioning” which allows the user to
place racks in any position, the XTP-1152 will identify the position and
process accordingly.
2D bar-code reading station
Will identify the 2D code on the base of each tube.
Based on the established X-Track reader hardware and software this
reader provides a very high read rate with all varieties of tubes. Tube
ID can be linked to a data-base using ODBC connectivity for a two-
way exchange of data.
Weigh station
A four position balance specifically designed for integration into
robotic systems to provide fast and accurate weighing (mg level).
Rack and tube holders
A variety of tube, rack, microplate, vial holders and adaptors are
available. Easily converted for either rapid change-over of racks
when handling large workloads or for flexibility to pick and sample
using a wide variety of racks, plates or tubes.
Wash station
To minimise carryover an active (pumped) washstation is provided.
PC based software
Includes database functionality and connectivity together with
ActiveX control. For application security a run-time module is
provided to allow applications to be run but not edited.
The FluidX XTP-1152 is a unique cherry picking and sample processing combination.
XTP-1152 12 position tube picker complete with 12 rack / plate
adaptor, tube picking mechanism and PC control software
Configuration 1 Base Unit, 2D bar-code reader
Configuration 2 Base Unit, 2D bar-code reader, linear bar-code reading
Configuration 3 Base Unit, 2D bar-code reader, linear bar-code reading,
balance
Configuration 4 Base Unit, 2D bar-code reader, linear bar-code reading,
balance, liquid handling with passive wash module.
Configuration 5 Base Unit, 2D bar-code reader, linear bar-code reading,
balance, liquid handling with active wash module.
Configuration 6 Base Unit, 2D bar-code reader, linear bar-code reading,
balance, liquid handling with passive wash module,
decapping
Configuration 7 Base Unit, 2D bar-code reader, linear bar-code reading,
balance, liquid handling, decapping module, active washing
system
Ordering Details
Applications
Cherry picking (tube or sample) de-fragmenting, re-arraying and
tare-weighting in preparation for dry compound addition.
As a sample processor this system is ideal for cherry picking, sample
transfer, reagent addition, serial dilution or assay preparation.
As a combination tube picker and sample processor the system
can automate processes that would otherwise require significant in-
tegration of separate systems.
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk20
XTL-96 Microtube Labelling System
The Xtl-96 is a highly specialised print and apply label applicator for
automatic application of individually printed labels on tubes in 24,
48 and 96-format racks.
Uses thermal printing method to label 800 tubes / hour.
Standard label size 28x15mm or 28x12.5mm, additional label sizes
are also available.
Suitable for use at low temperatures, as low as -80°C.
Compatible with 96-format tubes, from 0.5ml to 1.4ml. Either
capped or non-capped.
Can also be used with 2ml cryo tubes in 24 or 48 rack format.
“Quick-change” gripper allows the tube type being used to be
changed quickly and easily.
Integrated PLC unit provides maximum control.
Optional FluidX 2D data matrix rack reader can be integrated into
the unit to allow 2D codes on the tubes to be read and the data
incorporated into the label for “print and apply”.
Capper and automated decapper/recapper options are also
available.
Interface PC with serial RS232 connection (USB and Ethernet)
Software Windows XP Compatible GUI.
Tubes can be printed with individually labels
Print method Thermal transfer. Prints a variety of widely used barcodes or
human readable text.
Label size 2 types are available, specially designed labels can withstand
temperatures down to -40°C with no loss of adherence.
Media Any 96-format tube in volume range 0.5ml to 1.4ml
2ml cryotubes from Fluidx, Nunc, Greiner and Sarsted.
Operates on capped as well as non-capped tubes.
Capacity Approx. 800 tubes / hour.
Dimensions L x W x H in mm: 690 x 510 x 520
Electrical 100 - 240 VAC
Air supply 6 - 8 bar
Weight 25kg
Specifications
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk21
XTL-96 Microtube Labelling System (cont)
Cat No Description
75-0001 MICROTUBE LABELLING SYSTEM - XTL-96 Base Unit
Automated Microtube Printer Labeller Base Unit, requires gripper
kit.
75-0002 XTL-96 Standard Gripper
For:Fluidx, Matrix, Abgene, Micronic, Nunc 96 format tubes. 0.5ml
to 1.4 ml.
75-0003 XTL-96 Standard Gripper
For: Fluidx, Nunc, Greiner, Sarsted Cryo Tubes.
75-0004 XTL-96 Quick Change Gripper
Multiple tube handling in the same unit with Quick Lock head
(easy change), preparation and program per extra tube.
75-0005 XTL-96 Integrated Rack Scanner for 2D Coded Tubes
Rack Reader and Software Package
75-0006 XTL-96 Database Software
75-0101 XTL-96, 4 Rack tray Customisation
4 x 96 Tube racks can be placed and labelled in a single batch.
75-1001 Labels 12.2mm x 29mm
1000 labels per roll, white polyester, 50 micron, suitable for -80oC.
75-1002 Label and Ribbon Kit
Label 12.2mm x 29mm, 1000 labels per roll, white polyester, 50
micron, suitable for -80oC.
10 x 1,000 Label rolls and matched ribbon (TR221)
Ordering Details
FLUIDX OFFICES
UK (Head Office)
FluidX Ltd. Monks Heath Hall Workshops,
Chelford Road, Nether Alderley, Cheshire, SK10 4SY, UK.
Tel: +44 (0) 1625 861614
Fax: +44 (0) 1625 861615
Email: info@fluidx.co.uk
GERMANY, SWITZERLAND AND AUSTRIA
FluidX Germany, Vogelsangstr. 12,
D-61273 Wehrheim, Germany.
Tel: +49 (0) 6081-5836711
Fax: +49 (0) 6081-5836714
Email: info@fluidx.de
NORTH AMERICA
FluidX North America, 71 Commercial Street #226,
Boston, MA 02109, USA.
Tel: +1 (0) 617 886 9109
Fax: +1 (0) 617 209 1298
Email: info@fluidx.us
FAR EAST REGIONAL OFFICE
Nihon Fluidx
8N-07 6-9 Koyo-cho,
Naka Higashinada-ku, KOBE
658-0032 JAPAN
Tel: +81 78 821 1100
Fax: +81 78 821 1102
Email: info@fluidx.jp
For the list of our global distributors please visit www.fluidx.eu
www.fluidx.co.uk / Tel +44 (0) 1625 861614 / Email info@fluidx.co.uk