a-311 · storage 107 dir. of nursing 101g billing 101f welcome storage 101d admin dir. 101h...
Post on 04-Aug-2020
1 Views
Preview:
TRANSCRIPT
STORAGE
107
DIR. OFNURSING
101G
BILLING
101F
WELCOMESTORAGE
101DADMIN DIR.
101H
CONFERENCE
101J
MED. REC.
101L
WOMEN'S
111MEN'S
112
ENTRYVESTIBULE
100
ADULT DAYCENTER
110
STORAGE
109
STAIRWAY
S-3
ELEV
E-2
BUS.OFFICE
101B
MULTI-PURPOSE
106
GREATROOM
102
BISTRO
103
STAIRWAY
S-4
HAIR SALON
114
SCH.OFFICE
101M
THEATER
104
?
?
CORRIDOR
101C
9'-0"A1
9'-0"A1
9'-0"A1ADMISSIONS
101E
9'-0"A1
9'-0"A1
9'-0"A1
10'-0"A1
10'-0"G1
9'-0"G1
11'-0"G1
9'-0"A1
TOILET
101Q
9'-0"A1
9'-0"A2
9'-0"A1
9'-0"G1
9'-0"G1
8'-0"G1
8'-0"A1
9'-0"G1
9'-0"G1
10'-0"A1
10'-0"A1
10'-0"A1
9'-0"G1
8'-0"G1
9'-0"G1
VESTIBULE
105B
8'-0"G1
8'-6"G1 8'-6"G1
8'-0"G1
8'-0"G1
8'-6"G1
EQ
EQ
3'-6"
9'-0"G1
10'-0"A1
WORKROOM
101P
9'-0"A1
9'-0"A1
9'-0"A1
TOILET
114A
MECH
101NLOCKER RM
113A
LOCKER RMVEST
113
COUNTRYSTORE
105A
9'-0"A1
9'-0"G1
9'-0"A1
8'-6"G1
10'-0"G1
3'-5 5/8"2'-11 3/4" 3'-0 3/8"
2'-6 5/8"
2'-6
"3
'-2
"4
'-0
"
2'-6
"4
'-2
"2
'-4
1/8
"
8'-6"
OPEN TOABOVE
3'-0
"
3'-0"
3'-0
"
9'-0"G1
3
8'-6"G1
2'-0
"1'-10 3/8" 2'-1 5/8"
5'-0
"
6'-9 1/4" 7'-0 1/2"
3'-0
"
4'-6" 4'-6"
3'-0"
3'-0
"
3'-0" 3'-0"
10'-0"A1
EQ
EQ
EQ EQ
2'-6"
7'-8
"7
'-0
"4
'-5
"
7'-8
"7
'-0
"4
'-3
1/8
"
11
"
3'-11 5/8" 3'-10 3/8" 4'-3"
1'-6 5/8"
3'-5
"4
'-3
1/8
"
7'-8 5/8" 8'-0" 8'-0"
2'-3 5/8"2'-2 3/8"
6'-0
"6
'-0
"6
'-0
"2
'-1
"
11
"
2'-1
"1
1"
1'-6 5/8" 1'-5 3/8"EQ EQ
4'-0 5/8" 3'-11 3/8"
5'-0 5/8"
11
"
1'-6 5/8"
8'-0
"8
'-0
"8
'-0
"4
'-5
"
7'-0" 7'-0" 4'-11 3/8"
11
"2
'-0
"
2'-4" 2'-4"
EQ EQ
EQ
EQ
EQ
EQ
9'-1" 9'-1" 9'-1 1/2" 6'-5" 6'-5" 7'-6" 7'-6" 7'-6" 7'-6" 7'-6" 7'-6" 7'-6" 7'-6"
2'-6" 2'-6" 2'-0" 2'-0"
EQ
EQ
2'-5
"2
'-7
"
2'-7 1/4"2'-6 5/8"
3'-0"
3'-0" 3'-0"
3'-0
"3
'-0
"
8'-0"G1
EQ EQ
1'-6
"
EQ EQ 2'-0" 2'-0" EQ EQ
2'-0
"
9'-0"A1
9'-0"A1
2'-0"
2'-2
"7
'-10
"
2'-0
"3
'-0
"
EQ EQ
2'-0" 2'-0" 2'-0" 2'-0"
1'-0
"
2'-0
"3
'-0
"
3'-0" 3'-0"
EQ
3'-0
"3
'-0
"3
'-0
"3
'-0
"E
Q
1'-9"
2'-0
"2
'-0
"
EQ
EQ
4'-0
"1
'-6
"1
'-6
"
4'-6
3/8
"4
'-5
5/8
"
2'-6
"2
'-6
"
1'-0
"
1'-6"
1'-6"
5'-0"5'-0"
5'-0
"5
'-0
"
8'-0"G1
2'-0"2'-0"
8'-6"G1
3'-0
"3
'-0
"3
'-0
"
3
9'-8"G1
A-2363
OPEN TOABOVE
OPEN TOABOVE
OPEN TOABOVE
EQ
3'-0
"3
'-0
"3
'-0
"3
'-0
"E
Q
5'-5 3/4" 4'-0
"
CHAPEL/THEATER
108
4'-8"
3'-6"
9'-0"
3'-6"
4'-3 3/4"
6"
10'-0"G1
8'-6"G1
8'-6"G1
EQ
EQ
EQ
EQ
EQ
1. ALL CEILINGS SHALL BE ACT - TYPE 1, UON.
2. CEILING HEIGHTS INDICATED ARE NOMINAL.
3. CENTER CEILING GRIDS IN ROOMS TYPICALLY ASSHOWN EXCEPT WHERE DIMENSIONS AREPROVIDED
4. CENTER FIXTURES AND EQUIPMENTS IN ROOMSIN CEILING TILE OR IN HALF TILES OR IN SOFFITS ASSHOWN
5. VANITY LIGHT FIXTURES ARE TO BE CENTEREDOVER THE LAVATORY SINK WHEN THE SINK ISCENTERED IN THE COUNTERTOP, OTHERWISE THEVANITY LIGHT FIXTURES ARE TO BE CENTEREDOVER THE VANITY COUNTERTOP.
6. REFER TO ELECTRICAL DRAWINGS FOR LIGHTFIXTURE DESIGNATION.
7. ALL RECESSED LIGHT FIXTURES PENETRATINGTHE FIRE RATED CEILINGS ARE TO BE TENTED PERA0 6.2B.
8. PROVIDE ACCESS PANELS WHERE REQUIRED TOPROVIDE ACCESS TO EQUIPMENT. RE: MECH/ ELECAND SPECIFICATIONS. COORDINATE LOCATIONS W/ARCHITECT PRIOR TO BEGINNING WORK.
9. UNLESS PREFINISHED TO MATCH ADJACENTSURFACE, PAINT MECHANICAL GRILLES,DIFFUSERS, ACCESS PANELS AND OTHEREQUIPMENT, TYP.
10. CONTRACTOR IS REQUIRED TO CONSULT WITHARCHITECT PRIOR TO ADDING SOFFITS ORALTERING CEILING HEIGHTS INDICATED.
11. ALL GYPSUM BOARD ADJACENT TO SHOWERS &TUBS IS TO BE MOISTURE/MOLD RESISTANT(FIREBLOCK AQUA-TOUGH INTERIOR PANELS ORAPPROVED EQUAL). COORDINATE PRODUCTREQUIREMENTS WITH ASSEMBLY REQUIREMENTSAND FIRE RATING.
GENERAL NOTES
REFER TO ENLARGED UNIT PLANS FOR LIGHTING IN THISAREA. RE: SHEET A-330
FAUX STEEL BEAM. MATERIAL T.B.D. - (CAST FOAM)SPECIFICATION BY INTERIOR DESIGNER TO BE PROVIDEDIN FOLLOW-UP ADDENDUM.
CENTER FIXTURE IN CEILING
REFER TO ENLARGED TOILET ROOM REFLECTED CEILINGPLAN FOR DIMENSIONS THIS AREA. RE: SHEET A-330
CEILING PLAN KEY NOTES:
1
2
3
4
RCP MATERIALS LEGEND
2' - 0" x 2' - 0" ACOUSTIC CEILINGTILE SYSTEM, RE: SPEC.
PAINTED/TEXTURED GYPSUM BOARD.
NOTE: REFER TO GENERAL NOTE 11FOR MOLD/MILDEW RESISTANTLOCATION SPECIFICATIONS.
G1 ELEV
A1 ELEV
A2 ELEV
A3 ELEV
2' - 0" x 4' - 0" ACOUSTIC CEILINGTILE SYSTEM, RE: SPEC.
2' - 0" x 4' - 0" ACOUSTIC CEILINGTILE SYSTEM WITH VINYL COATEDCEILING TILES, RE: SPEC.
RECESSED CAN(REFER TO SPEC)
RECESSED WALL WASHER(REFER TO SPEC)
CEILING SYMBOLS LEGEND
2X2 RECESSED FLUORESCENT(REFER TO SPEC)
MINI PENDANT(ALLOWANCE: $400)
WALL SCONCE(ALLOWANCE: $225)
2X4 RECESSED FLUORESCENT
PENDANT FIXTURE(ALLOWANCE: $550)
VANITY BAR LIGHT(ALLOWANCE: $250)
TRACK LIGHTING(ALLOWANCE: $500)
SURFACE MOUNTED FIXTURE(ALLOWANCE: $300)
1X4 SURFACE MNT'D FLUORESCENT
HEAT LAMP
NURSE CALL LIGHT
SUPPLY DIFFUSER OR GRILLE
RETURN AIR GRILLE
EXIT LIGHT
UNDER COUNTER LIGHTING/LED STRIP
NC
NOTE: ALLOWANCES LISTED ARE PRODUCT ONLY. DOESNOT INCLUDE: LABOR, DELIVERY, TAX, MARK-UP, INSTALL.
1X4 RECESSED FLUORESCENT
2X4 SURFACE MNT'D FLUORESCENT
EXHAUST FAN
ZONE 1
ZONE 2
ZONE 4
ZONE 5
ZONE 3
Seal:
LBA Project Number:
Date:
2013 Copyright c
5650 DTC Pkwy. I Suite 200 I Englewood I CO 80111Ph: 303.773.0436 I Fax: 303.773.8709
Lantz-Boggio Architects, P.C.
DRAWN BY:
Structural Engineer:Jirsa Hedrick & Associates7000 E. Belleview Ave. Suite 250Greenwood Village, CO 80111Ph. 303.839.1963Contact: Steve Jirsa
Mechanical/Plumbing Engineer:Given & Associates, Inc.735 S. Xenon Court, Suite 201Lakewood, CO 80228Ph. 303.716.1270Contact: Jeff Given
Electrical Engineer:Alber Engineering5173 Oak Hollow DriveMorrison, CO 80465Ph. 303.736.2739Contact: Jerry Alber
Interior Design:LBA Interiors5650 DTC Parkway, Suite 100Englewood, CO 80111Ph. 303.773.0436Contact: Mary Lou Parham
Owner:Campbell County Memorial Hospital501 South Burma Ave.Gillette, WY 82716P.O. Box 3011Gillette, WY 82717Ph. 307.688.1000
Civil Engineer:PCA Engineering, Inc.P.O. Box 21854506 Wigwam Blvd.Gillette, WY 82718Ph. 307..687.0600Contact: Clark Sanders
Food Service:United Restaurant Supply, Inc.725 Clark PlaceColorado Springs, CO 80915Ph. 719.574.3220Contact: Jon Bluhm
Landscape Architect:Four Front Design, Inc.517 7th StreetRapid City, SD 57701Ph. 605.342.9470Contact: Eirik Heikes
Key Plan:
NO
TIC
E: T
he
se d
ocu
me
nts
are
instr
um
ents
of pro
fess
iona
l serv
ice,a
nd
info
rmatio
n c
onta
ined there
in is
incom
ple
te u
nle
ss
used in
con
junct
ion w
ith L
antz
-Boggi o
's in
terp
reta
tions, desic
ions, obse
rva
tions
and a
dm
inis
tratio
ns.
Use
or
repro
du
ctio
n o
f th
ese d
ocu
me
nts
in w
hole
or
part
with
out L
antz
- B
oggio
's c
onse
nt is
in v
iola
tion o
f co
mm
on
law
, co
pyr
ights
, sta
tuto
ry a
nd o
ther
reser v
ed r
ights
. R
efe
r to
Act
17 U
.S.C
., p
ar.
51
1 (
1991).
whuic
h p
reem
pts
sta
te a
nd
local p
ublic
reco
rds a
c t. R
efe
r to
Act 1
7 U
.S.C
., p
ar
301 (
19
91).
2012.3000
October 31, 2013
FIRST FLOOR REFLECTEDCLNG PLAN - ZONE 3
A-311.3
PIONEER MANOR
2012.3000
Gillette/ Wyoming
Author
SCALE: 1/8" = 1'-0"1 FIRST FLOOR RCP - ZONE 3NORTH
ZO
NE
1
ZO
NE
3
ZO
NE
2
ZO
NE
3
ZO
NE
3
ZO
NE
4
ZO
NE
3
ZO
NE
5
No. Date Description1 05/17/2013 Design Development
2 10/31/2013 Construction Documents
3 12/05/2013 Addendum 2