a comparison of multimodal chromatography resin: case study

Post on 15-Apr-2017

237 Views

Category:

Health & Medicine

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Mixed Mode Chromatography and KBI’s mAB Purification Process Platform• Mixed Mode resins are ideal for KBI’s mAb platform process since by the nature of

our business there is a significant diversity in mammalian cell clones/cell culture harvest and mAbs

• Mixed mode resins can provide added robustness to a mAb platform to reduce both HMW and HCP impurities

• Given the complexity of mixed mode resin interactions, optimizing a mixed mode chromatography step can be time consuming and potentially material limiting

1

DS ProcessPlatform

Cell line diversity

Media/feed type

diversity

HCP level variability

Cell density variability

HMW level variability

Objectives• Determine if there is at least one mixed mode cation

exchange/hydrophobic interaction polishing step resin that performs well for multiple mAbs• Ideal candidates for a mAb process platform

• Present a high throughput, low material requirement method for identifying optimal operating ranges for multiple mixed mode resins in a single set of experiments• Show how the method can be use to identify optimal

chromatography conditions

• Show the relationship between the high throughput screening data and chromatography performance for different mAbs

2

Mixed-mode cation exchange/hydrophobic interaction resins

3

NuviaTM cPrimeTM

Bio-Rad Laboratories

MX-Trp-650MTosoh

EshmunoTM HCXEMD Millipore

CaptoTM MMCGE Healthcare

TM

High Throughput Screening: Plate Experimental Design

05/03/2023

4

Variable Conditions Evaluated

Load pH 4, 5, 6, 7, 8

Elution pH 4, 5, 6, 7, 8

Elution [NaCl] (M) 0.20, 0.65, 1.10, 1.55, 2.00

• Three mAbs evaluated under a series of conditions• One plate executed per load pH

5

• The low yield process condition zone size varies significantly with respect to resin, mAbs and process conditions and are easily identifiable

• In general, Capto MMC has slightly larger low yield zones for the mAbs and test conditions within our typical operating pH range .

• In general, each resin has a characteristic surface response map profile

Findings regarding the relationship between HT filter plate and chromatography data• High throughput filter plate data can be used to quickly

limit the focus of a chromatography evaluation using minimal amounts of the target protein• pH and NaCl conditions not favorable for high yields

are easily identifiable• There is a correlation between yield variability for each

condition (load pH and elution pH) and monomer selectivity• more variability leads to better selectivity