A I t t LtdAurora Instruments Ltd.

Smart Solutions for Elemental AnalysisSmart Solutions for Elemental Analysis

Aurora Group of Companies

Over 16 years, Aurora Instruments has been dedicated to designing, Over 16 years, Aurora Instruments has been dedicated to designing, manufacturing and servicing analytical instruments.manufacturing and servicing analytical instruments.

Aurora Instruments Ltd.

Aurora Biomed IncAurora Biomed Inc.

Aurora BioPharma Ltd.

A i Ab i SAtomic Absorption Spectrometer

AI 1200AI 1200

W 65 X D 55 X H 37 cm

AI 1200 Configurations

AI 1200 Fl• AI 1200 Flame

• AI 1200 Flame/Graphite Furnace (F/GF)AI 1200 Flame/Graphite Furnace (F/GF)

• AI 1200 Vapor Generation (VG)AI 1200 Vapor Generation (VG)

AI 1200 Features

• Switchable single/double beam optics• Switchable single/double beam optics

• Automatic Switch between all atomizers

• Auto aligned & five-lamp turret

• Transversely heated GF tube

• High GF heating rate ( upto 3800K/s)

• On-line dilution for single standard calibration for flame

systemsystem

AI 1200 Features

• Universal XYZ auto sampler - Best of any AA

• Industry leading AISPEC software

• Built in high intensity power supply• Built in high-intensity power supply

• Unmatched performance for flame and GF analysisp y

• Smallest footprint with big engine!

• with built in GF power supply and optics (f=300mm)

AI 1200 Flame

• Solid Teflon spray chamber

• Titanium coated burner head

• Inert to both acids and organics

• Corrosion resistant• Corrosion resistant

• Nebulizer impact bead p

Flame AAS Performance

Exceptional performanceExceptional performance::

2 ppm Cu sample is 0.4

ABS over ten 4 secABS over ten 4 sec.

integrations with less

than 0.5% RSD

Online Dilution

• Use a single stock solution to create entire set of calibration standards

• Decrease time and increase accuracy of results• Patented technology

Safety Interlocks

St d d S f t I t l kStandard Safety Interlocks

• Burner head detection

• Flame sensor

• Automatic shut off

G• Gas pressure sensor

• Automated oxidant changeoverAutomated oxidant changeover

AI 1200 Graphite Furnace

• Heating rate of 3800 K/sHeating rate of 3800 K/s

• Up to 30 programmable heating steps to suit

any application

• Fast-dry technique with autosampler greatly y q p g y

reduces analysis times

• Superior drying stage temperature control

• Detection limits in the ppb rangepp g

Transverse Heating GF

• Transversely heated furnace provides spatially isothermalprovides spatially isothermal temperature gradient

Benefits:

•Reduced memory effects•Reduced memory effects

•Lower background signals

•High atomization efficiency6 pictogram Cd samplep g p

Fast Dry Technique

Benefits:

Programming injection speed, preheating of temperatures, and cooling times

Benefits:

1. Decrease Analysis time• Normally, atomization step takes 1-2 minutes

due to time required to dry the atomizer before sample introduced and cooling times after. p gFast dry technique reduces time to seconds.

2 Increase Detection Limits2. Increase Detection Limits• Reduce splattering by slowing depositing sample onto a preheated

surface thus giving improved reproducibility, sensitivity and detection limitslimits

AI 1200 Vapor Generation (VG)

VG 411VG 411• Determination of hydride-forming elements

• Mercury analysis

• Revolutionary gas-liquidseparator

• 3 layer reaction/mixing manifoldmanifold

Vapor/Hydride Generation AAS

Sub trace detection limits for Hg & hydride forming elements

Benefits

• Sub-trace detection limits for Hg & hydride forming elements

• Quartz tube atomizer provides enhanced sensitivities and reduced

interferences

• Controllable peristaltic pumps for reproducible measurements

• Limitless flexibility to optimize instrument according to application• Limitless flexibility to optimize instrument according to application

RSD of 15 ng/ml Hg sampleg g p

Background Correction

The AI 1200 AAS employs two correction techniques:

•Smith-Hieftje / Self Reversal

•Deuterium Lamp Correctionindustry leading 1000Hz1000Hz modulation frequency

Advantages of Zeeman

Zeeman IF:

-Structured Background Interferences are Expected (i.e. As in a high PO4

-3 Matrix).g 4 )-Spectral Interferences are Expected (i.e. As in High Al Matrix).

D t i IFDeuterium IF:

- Don’t Expect Structured Background or Spectral Interferences p g p(95+% of the Existing Applications of AA).- Want Maximum Sensitivity.

W t M i D i R- Want Maximum Dynamic Range.- Want High Performance while limiting instrument costs.

Limitation of Zeeman Correction

• Sensitivity loss for some elements (Al, Sb,As, Cu, Se, Te)• Due to complexity of splitting of absorption profile in

magnetic field

• Loss of dynamic range

• Increase in calibration curvature resulting in roll over point

• Cost

Universal XYZ Autosampler

• Compatible with ALL atomizers: F/GF/VG

• 3D movement in all directions

• Virtually UNLIMITED sample capacityp y

• Robust movement compared rotary designdesign

•Adapt to ANY sample container: test p ptubes, cups, micro plates, etc

XYZ AUTOSAMPLER

Use of Autosampler + AISPECTM software allows:

• Calibration from a single standard

• Offers on line dilution• Offers on-line dilution

• Perform Fast-Dry furnace techniquesP i i j ti d h ti f t t• Programming injection speed, preheating of temperatures, and cooling times

Benefits:• Increased sensitivities• Reduced analysis timesReduced analysis times• High precision

AISPECTM Software

• Standard windows interface

• Template/worksheet environment

• Ability to customize the window view

Single Run – allow operator to test a method at any time

Batch Run – automated/manual control of multiple samples

AISPECTM Software

• Wavelength scan feature to further assist method g

development

• Easy calibration of instrument

• No Stimulations

• Real-time graphics allow easy interpretation of data

• Export files to LIMS and other software for quality• Export files to LIMS and other software for quality

assurance and control

AISPECTM Software

Benefits

• Easy to use

• Lower learning curve

• Reduced training cost

Competitor Analysis

Aurora AI 1200 Perkin Elmer Varian Thermo

Automatic-Switch – F/GF High End ($) Dual, Simultaneous

Dual, Simultaneous

Single/Double Beam No No NoSingle/Double Beam No No No

On-Line Dilution No SIPS System ($$) No

Optical Modulation 1000 Hz Up to 220 Hz Up to 220 Hz Up to 220 Hz

1 Autosampler for F/GF/VG No No No

Transverse Heating Graphite Tube (THGT)

High End No No

Background D2/SH D2/Zeeman D2/ Zeeman D2 (optionalBackground D2/SH D2/Zeeman D2/ Zeeman D2 (optional Zeeman)

Built-in High Intensity Power No No No

Competitor Analysis

Aurora AI 1200 GBC Analytika Jena Shimadzu

Automatic-Switch – F/GF No Yes, Manual Switching Platform

Top Model

Single/Double Beam No No No

On-Line Dilution No No No

Optical Modulation 1000 Hz N/A N/A Less than 220 Hz

1 Autosampler for F/GF/VG No No Yes (F/GF only)

Transverse Heating Graphite High End High End Model (Nov NoTransverse Heating Graphite Tube (THGT)

High End Model (Ultra-Z)

High End Model (Nov AA 440G)

No

Background D2/SH D2 & Zeeman (High End)

D2 or Zeeman; Both only High End (Zeenit

D2/SH( g ) y g (

700)

Built-in High Intensity Power No No No