a7 selection tables€¦ · suconet p ® (klöckner-möller), modulink p (weidmüller) modbus...
Post on 04-Feb-2021
4 Views
Preview:
TRANSCRIPT
-
1078
ÖLF
LEX®
ACC
ESSO
RIES
FLEX
IMAR
K®SI
LVYN
®SK
INTO
P®EP
IC®
HIT
RON
IC®
ETH
ERLI
NE®
UN
ITRO
NIC
®AP
PEN
DIX
For current information see: www.lappgroup.com
A7 Selection tablesUNITRONIC® BUS and ETHERLINE® – which cable suits which fieldbus system?
Legend Trademarks7-W = 7-wire braided conductorAS-I = AS-INTERFACECOMBI IBS = Installation bus cable for INTERBUSDN = Device NetEIB = European Installation BusFD = Cable suitable for drag chainsFRNC = Flame Retardant Non CorrosiveG = Rubber outer sheath (EPDM)H = Halogen-free materialIBS = Remote bus cable for INTERBUSL2 = Abbr. for SINEC L2-DP
LD = Long distanceP = Polyurethane outer sheathPB = PROFI BUSPE = Polyethylene outer sheathPROFIBUS-DP = Decentralised PeripheryPROFIBUS-FMS = Fieldbus Message SpecificationPROFIBUS-PA = Process AutomationTPE = Thermoplastic elastomerYv = Cable for routing outdoors/underground with reinforced PVC outer sheathYY = Twin PVC outer sheath
CC-Link® = is a registered trademark of CLPA, JapanDeviceNetTM = is a registered trademark of Open Device Vendors Association (ODVA)FoundationTM = is a registered trademark of Foundation FieldbusINTERBUS® = is a registered trademark of Phoenix Contact GmbH & Co.Modulink® P = is a registered trademark of Weidmüller GmbH & Co.SIMATIC® = is a registered trademark of SIEMENS AGSINEC® = is a registered trademark of SIEMENS AGSUCOnet P® = is a registered trademark of Klöckner + Moeller GmbHVariNet®-P = is a registered trademark of Pepperl + Fuchs GmbH
Usage criteria Cable designationPage 379 381 381 381 380 326 332 332 332 360 342 348 349 346 338 332 332 332 360 344 340 363 363 365 335 375 331 364
327 339
UN
ITRO
NIC
® B
US
IBS
A
UN
ITRO
NIC
® B
US
IBS
P C
OM
BI A
UN
ITRO
NIC
® B
US
IBS
FD P
UN
ITRO
NIC
® B
US
IBS
FD P
CO
MBI
UN
ITRO
NIC
® B
US
IBS
Yv C
OM
BI
UN
ITRO
NIC
® B
US
LD A
+ B
US
LD F
D P
A
UN
ITRO
NIC
® B
US
PB A
UN
ITRO
NIC
® B
US
PB P
E
UN
ITRO
NIC
® B
US
PB 7
-W A
UN
ITRO
NIC
® B
US
PA
UN
ITRO
NIC
® B
US
PB F
D P
UN
ITRO
NIC
® B
US
PB T
ORS
ION
UN
ITRO
NIC
® B
US
PB F
ESTO
ON
UN
ITRO
NIC
® B
US
PB F
D P
HYB
RID
UN
ITRO
NIC
® B
US
PB Y
v, P
B YY
UN
ITRO
NIC
® B
US
PB P
E FC
UN
ITRO
NIC
® B
US
PB H
FC
UN
ITRO
NIC
® B
US
PB P
FC
UN
ITRO
NIC
® B
US
PA F
C
UN
ITRO
NIC
® B
US
PB F
D P
FC
UN
ITRO
NIC
® B
US
PB B
URI
AL F
C
UN
ITRO
NIC
® B
US
CAN
UN
ITRO
NIC
® B
US
CAN
FD
P
UN
ITRO
NIC
® B
US
CAN
BU
RIAL
UN
ITRO
NIC
® B
US
PB H
EAT
180
UN
ITRO
NIC
® B
US
IS
UN
ITRO
NIC
® B
US
PB T
RAY
UN
ITRO
NIC
® B
US
CAN
TRA
Y
Standards
UL/CSA-approved
Installation
Fixed installation
Flexible
Highly flexible (drag chains etc.)
Suitable for outdoor use/direct burial, UV-resistant
Mean characteristic Impedance
100–120 ohms
150 ohms
Dimensions
In mm2, or diameter in mm, or AWG size
3 x 2 x 0.22
3 x 2 x 0.25
3 x 2 x 0.25 + 3 x 1.0
3 x 2 x 0.22 + 3 x 1.0
1 x 2 x 0.22/2 x 2 x 0.22/3 x 2 x 0.22
1 x 2 x 0.64
1 x 2 x 1.0
1 x 2 x 0.8
1 x 2 x 0.64 + 4 x 1.5
1 x 2 x 0.25/2 x 2 x 0.25
1 x 2 x 0.34/2 x 2 x 0.34
1 x 2 x 0.5/2 x 2 x 0.5
1 x 2 x 0.75/2 x 2 x 0.75
2 x 6 + 2 x 2.5 + 1 x 4 x 0.5
Bus systems
INTERBUS® DIN 19258 EN 50251 sensor/actuator bus
INTERBUS® (Phoenix Contact)
SUCOnet p® (Klöckner-Möller), Modulink® P (Weidmüller) MODBUSVariNet®-P (Pepperl + Fuchs)
PROFIBUS-DP, -FMS, FIP
PROFIBUS-PA, FoundationTM Fieldbus
CAN ISO 11898, CAN open
AS-INTERFACE
EIB
CC-Link®
Device NetTM (Allen-Bradley/Rockwell Automation)
Industrial Ethernet/Fast Ethernet
ISOBUS (ISO 11783-2)
-
1079
ÖLF
LEX®
ACC
ESSO
RIES
FLEX
IMAR
K®SI
LVYN
®SK
INTO
P®EP
IC®
HIT
RON
IC®
ETH
ERLI
NE®
UN
ITRO
NIC
®AP
PEN
DIX
For current information see: www.lappgroup.com
Selection tables A7UNITRONIC® BUS and ETHERLINE® – which cable suits which fieldbus system?
Usage criteria Cable designationPage 328 329 329 329 328 361 361 361 361 362 362 362 362 382 382 376 376 377 377 417 417 418 429 420 435 430 438 434 436 425 445 444 419 417 429 449
420
UN
ITRO
NIC
® B
US
ASI (
G)
UN
ITRO
NIC
® B
US
ASI L
D F
D P
UN
ITRO
NIC
® B
US
ASI F
D (T
PE) A
U
NIT
RON
IC® B
US
ASI F
D P
FRN
CU
NIT
RON
IC® B
US
ASI (
PVC
) AU
NIT
RON
IC® B
US
DN
TH
ICK
FRN
CU
NIT
RON
IC® B
US
DN
TH
IN F
RNC
UN
ITRO
NIC
® B
US
DN
TH
ICK
YU
NIT
RON
IC® B
US
DN
TH
IN Y
UN
ITRO
NIC
® B
US
DN
TH
ICK
FD P
UN
ITRO
NIC
® B
US
DN
TH
IN F
D P
UN
ITRO
NIC
® B
US
DN
TH
ICK
FD Y
UN
ITRO
NIC
® B
US
DN
TH
IN F
D Y
UN
ITRO
NIC
® B
US
EIB,
BU
S EI
B H
UN
ITRO
NIC
® B
US
EIB
CO
MBI
UN
ITRO
NIC
® B
US
FF 3
, FF
3 AR
MU
NIT
RON
IC® B
US
FF 2
UN
ITRO
NIC
® B
US
CC
UN
ITRO
NIC
® B
US
CC
FD
P F
RNC
ETH
ERLI
NE®
H, P
ETH
ERLI
NE®
H-H
ETH
ERLI
NE®
H F
LEX,
P-F
LEX
ETH
ERLI
NE®
PN
Cat
.5ET
HER
LIN
E® F
D C
at.5
ETH
ERLI
NE®
PN
Cat
.5 F
DET
HER
LIN
E® P
N F
LEX
Cat
.5ET
HER
LIN
E® C
at.5
ARM
ETH
ERLI
NE®
Cat
.5 F
RNC
HYB
RID
ETH
ERLI
NE®
Cat
.6A
ETH
ERLI
NE®
Cat
.7ET
HER
LIN
E® T
ORS
ION
Cat
.5ET
HER
LIN
E® F
D P
Cat
.6ET
HER
LIN
E® T
ORS
ION
Cat
.6A
ETH
ERLI
NE®
FD
Cat
.6A
ETH
ERLI
NE®
PN
Cat
.6A FL
EXET
HER
LIN
E® E
C F
LEX/
FD C
at.5
eET
HER
LIN
E® Y
FLE
X C
at.5
eET
HER
LIN
E® T
RAY
ER P
N Y
FC
ETH
ERLI
NE®
TO
RSIO
N C
at.7
Standards
UL/CSA-approved
Installation
Fixed installationFlexibleHighly flexible (drag chains, torsional stress etc.)Suitable for outdoor use/direct burial, UV-resistant
Mean characteristic Impedance
100–120 ohms
Dimensions
In mm2, or diameter in mm, or AWG size1 x 2 x 0.5, 2 x 2 x 0.52 x 1.52 x 2.5AWG 18 + 15AWG 24 + 222 x 2 x 0.82 x 2 x 0.8 + 3 x 1.52 x 2 x AWG 24/1 and 4 x 2 x AWG 24/14 x 2 x AWG 24/14 x 2 x AWG 24/72 x 2 x AWG 26/7 and 4 x 2 x AWG 26/74 x 2 x AWG 26/72 x 2 x AWG 22/12 x 2 x AWG 26/19, 4 x 2 x AWG 26/192 x 2 x AWG 22/72 x 2 x AWG 22/191 x 2 x 1.1 + 1 x 1.11 x 2 x 1.13 x 1 x AWG 204 x 2 x AWG 22/14 x 2 x AWG 22/74 x 2 x AWG 23/72 x 2 x AWG 22/7 + 4 x 1.54 x 2 x AWG 26/19
Bus systems
INTERBUS® DIN 19258 EN 50251 sensor/actuator busINTERBUS® (Phoenix Contact)SUCOnet p® (Klöckner-Möller), Modulink® P (Weidmüller) MODBUS VariNet®-P (Pepperl + Fuchs)PROFIBUS DIN 19245 EN 50170PROFIBUS-DP, -FMS, FIPPROFIBUS-PA, FoundationTM FieldbusCAN ISO 11898, CAN openAS-INTERFACEEIBCC-Link®
Device NetTM (Allen-Bradley/Rockwell Automation)Industrial Ethernet/Fast EthernetPROFINETEtherCAT
Legend Trademarks7-W = 7-wire braided conductorAS-I = AS-INTERFACECOMBI IBS = Installation bus cable for INTERBUSDN = Device NetEIB = European Installation BusFD = Cable suitable for drag chainsFRNC = Flame Retardant Non CorrosiveG = Rubber outer sheath (EPDM)H = Halogen-free materialIBS = Remote bus cable for INTERBUSL2 = Abbr. for SINEC L2-DP
LD = Long distanceP = Polyurethane outer sheathPB = PROFI BUSPE = Polyethylene outer sheathPROFIBUS-DP = Decentralised PeripheryPROFIBUS-FMS = Fieldbus Message SpecificationPROFIBUS-PA = Process AutomationTPE = Thermoplastic elastomerYv = Cable for routing outdoors/underground with reinforced PVC outer sheathYY = Twin PVC outer sheath
CC-Link® = is a registered trademark of CLPA, JapanDeviceNetTM = is a registered trademark of Open Device Vendors Association (ODVA)FoundationTM = is a registered trademark of Foundation FieldbusINTERBUS® = is a registered trademark of Phoenix Contact GmbH & Co.Modulink® P = is a registered trademark of Weidmüller GmbH & Co.SIMATIC® = is a registered trademark of SIEMENS AGSINEC® = is a registered trademark of SIEMENS AGSUCOnet P® = is a registered trademark of Klöckner + Moeller GmbHVariNet®-P = is a registered trademark of Pepperl + Fuchs GmbH
-
1080
ÖLF
LEX®
ACC
ESSO
RIES
FLEX
IMAR
K®SI
LVYN
®SK
INTO
P®EP
IC®
HIT
RON
IC®
ETH
ERLI
NE®
UN
ITRO
NIC
®AP
PEN
DIX
For current information see: www.lappgroup.com
A7 Selection tablesUNITRONIC® BUS and ETHERLINE® – technical data
** without FC = 65 mm/FC = 120 mm
Usage criteria Cable designationPage 379 381 380 326 327 332 342 338 360 363 363 376 376 364 331
344
UN
ITRO
NIC
® B
US
IBS
fixed
inst
alla
tion
UN
ITRO
NIC
® B
US
IBS
FD P
high
ly fl
exib
le a
pplic
atio
n
UN
ITRO
NIC
® B
US
IBS
Yvsu
itabl
e fo
r ou
tdoo
r us
e/di
rect
bur
ial
UN
ITRO
NIC
® B
US
LDfix
ed in
stal
latio
n
UN
ITRO
NIC
® B
US
LD F
D P
high
ly fl
exib
le a
pplic
atio
n
UN
ITRO
NIC
® B
US
PBfix
ed in
stal
latio
n
UN
ITRO
NIC
® B
US
PB F
D P
+ P
B FD
P F
Chi
ghly
flex
ible
app
licat
ion
UN
ITRO
NIC
® B
US
PB Y
vsu
itabl
e fo
r ou
tdoo
r us
e/di
rect
bur
ial
UN
ITRO
NIC
® B
US
PA (B
U +
BK)
fixed
inst
alla
tion
UN
ITRO
NIC
® B
US
CAN
fixed
inst
alla
tion
(0.2
2 m
m2 )
UN
ITRO
NIC
® B
US
FD P
CAN
FD
Phi
ghly
flex
ible
app
licat
ion
(0.2
5 m
m2 )
UN
ITRO
NIC
® B
US
FF 3
ARM
fixed
inst
alla
tion
UN
ITRO
NIC
® B
US
FF 2
fixed
inst
alla
tion
UN
ITRO
NIC
® B
US
CAN
TRA
Y
UN
ITRO
NIC
® B
US
PB T
RAY
Parameter
Characteristic impedance Ω 100 100 100 100–120100–120
150 +/-15
150 +/-15
150 +/-15
100 +/-20 120 120 100 100 120
150 +/-15
Mutual capacitance (800 Hz) max. nF/km 60 60 60 60 60 30 30 30 52 40 40 56 65 40 30
Peak operating voltage V (not for power applications)
250 250 250 250 250 250 250 250 250 250 250 300 300 250 250
Test voltage, core/core, Ueff V 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2000 2000
Conductor resistance (loop) Data network cable pair max. Ω/km
186 159.8 186 186 159.8 110 145, 133 115 44 186 159.8 ≤ 24 ≤ 24 110.8 110
Minimum bending radius, fixed installation 8 x D – 8 x D 8 x D – 75 mm – 75 mm 65 mm 8 x D – 15 x D 15 x D 8 x D 8 x D
Minimum bending radius, flexing – 15 x D – – 15 x D – ** – – – 15 x D – – – –
Temperature range from °Cfixed installation to °C
- 30 + 80
- 40 + 80
- 40 + 70
- 40 + 80
- 40 + 80
- 40 + 80
- 40 + 80
- 40 + 80
- 30 + 80
- 30 + 80
- 40 + 80
- 25 + 80
- 25 + 105
- 40 + 80
- 40 + 80
Temperature range from °Cflexing to °C –
- 30 + 70 –
- 5 + 70
- 30 + 70 –
- 30 + 70 – –
- 5 + 70
- 30 + 70 – –
- 10 + 70
- 10 + 70
Usage criteria Cable designationPage 377 377 417 417 417 418 418 418 419 419 422 430 430 436
UN
ITRO
NIC
® B
US
CC
UN
ITRO
NIC
® B
US
CC
FD
P F
RNC
ETH
ERLI
NE®
H C
at.5
e
ETH
ERLI
NE®
P C
at.5
e
ETH
ERLI
NE®
H-H
Cat
.5e
ETH
ERLI
NE®
H F
LEX
Cat
.5e
ETH
ERLI
NE®
P F
LEX
Cat
.5e
ETH
ERLI
NE®
Y F
LEX
Cat
.5e
ETH
ERLI
NE®
Y E
C F
LEX
Cat
.5e
ETH
ERLI
NE®
P E
C F
LEX
Cat
.5e
ETH
ERLI
NE®
P E
C F
D C
at.5
e
ETH
ERLI
NE®
PN
Cat
.5 Y
FLE
X FC
ETH
ERLI
NE®
PN
Cat
.5 F
RNC
FLE
X FC
ETH
ERLI
NE®
TO
RSIO
N C
at.5
Parameter
Characteristic impedance Ω 110 110 100 100 100 100 100 100 100 100 100 100 100 100
Mutual capacitance (800 Hz) max. nF/km 60 60 48 46 46 48 48 – – – – – – –
Peak operating voltage V (not for power applications)
300 300 125 125 125 125 125 125 100 100 100 125 125 100
Test voltage, core/core, Ueff V 2000 2000 1000 1000 1000 1000 1000 1000 1000 1000 1000 2000 2000 700
Conductor resistance (loop) Data network cable pair max. Ω/km
37.8 37.8 192 186.6 186.6 284 284 – – – – – – –
Minimum bending radius, fixed installation 15 x D 4 x D 7.5-8 x D 7.5-8 x D 8 x D 8 x D 8 x D 8 x D 4 x D 4 x D 4 x D 10 x D 4 x D 5 x D
Minimum bending radius, flexing – 8 x D – – – 15 x D 15 x D 15 x D 8 x D 8 x D 8 x D 15 x D 8 x D 5 x D
Temperature range from °Cfixed installation to °C
- 40 + 70
- 40 + 80
- 30 + 80
- 30 + 80
- 30 + 80
- 30 + 80
- 30 + 80
- 40 + 80
- 30 + 80
- 40 + 80
- 40 + 80
- 40 + 80
- 25 + 80
- 40 + 80
Temperature range from °Cflexing to °C –
- 40 + 80
- 5 + 60
- 5 + 60
- 5 + 60
- 5 + 60
- 5 + 60
- 10 + 70
- 5 + 50
- 30 + 50
- 30 + 50
- 20 + 60
- 25 + 80
- 40 + 80
-
1081
ÖLF
LEX®
ACC
ESSO
RIES
FLEX
IMAR
K®SI
LVYN
®SK
INTO
P®EP
IC®
HIT
RON
IC®
ETH
ERLI
NE®
UN
ITRO
NIC
®AP
PEN
DIX
For current information see: www.lappgroup.com
Selection tables A7UNITRONIC® BUS and ETHERLINE® – technical data
Usage criteria Cable designationPage 429 429 429 429 420 435 444 444 449
ETH
ERLI
NE®
PN
Cat
.5e
Y
ETH
ERLI
NE®
TRA
Y ER
PN
Y F
C
ETH
ERLI
NE®
Y F
C C
at.5
ETH
ERLI
NE®
Cat
.5e
YY
ETH
ERLI
NE®
FD
P C
at.5
e
ETH
ERLI
NE®
FD
P F
C C
at.5
hi
ghly
flex
ible
app
licat
ion
ETH
ERLI
NE®
PN
Cat
.6A
FRN
C F
C +
ETH
ERLI
NE®
PN
Cat
.7 F
RNC
ETH
ERLI
NE®
PN
Cat
.6A
P FC
+ET
HER
LIN
E® P
N C
at.7
P
ETH
ERLI
NE®
PN
Cat
.6A
Y FC
+ET
HER
LIN
E® P
N +
Cat
.7 Y
ETH
ERLI
NE®
PN
Cat
.6A
Y FL
EX F
C
ETH
ERLI
NE®
PN
Cat
.6A
FRN
C F
LEX
FC
ETH
ERLI
NE®
FD
Cat
.6A
+ TO
RSIO
N Y
Cat
.6A
ETH
ERLI
NE®
FD
P C
at.6
A + T
ORS
ION
P C
at.6
A
ETH
ERLI
NE®
TO
RSIO
N C
at.7
Parameter
Characteristic impedance Ω 100 100 100 100 100 100 100 100 100 100 100 100 100 100
Mutual capacitance (800 Hz) max. nF/km 48 48 48 48 50 52 – – – – – – – 50
Peak operating voltage V (not for power applications)
125 125 125 125 125 125 125 125 125 125 125 125 125 125
Test voltage, core/core, Ueff V 1000 2000 1000 1000 1000 700 1000 1000 1000 1000 1000 1000 1000 750
Conductor resistance (loop) Data network cable pair max. Ω/km
118 115 115 118 290 120 118 118 118 143 143 175 175 175
Minimum bending radius, fixed installation 7.5 x D 10 x D 10 x D 4 x D 8 x D 5 x D 4 x D 4 x D 4 x D 8 x D 8 x D 8 x D 8 x D 8 x D
Minimum bending radius, flexing 15 x D 15 x D 15 x D 8 x D 15 x D 8 x D 8 x D 8 x D 8 x D 15 x D 15 x D 15 x D 15 x D 15 x D
Temperature range from °Cfixed installation to °C
- 40 + 70
- 40 + 80
- 40 + 80
- 25 + 80
- 30 + 80
- 30 + 70
- 25 + 80
- 40 + 80
- 30 + 80
- 10 + 70
- 25 + 80
- 40 + 80
- 40 + 80
- 40 + 80
Temperature range from °Cflexing to °C
- 5 + 50
- 20 + 60
- 20 + 60
- 5 + 70
- 5 + 70
- 20 + 60 – – –
- 10 + 70
- 25 + 80
- 10 + 70
- 30 + 70
- 30 + 70
Usage criteria Cable designationPage 328 328 329 329 329 328 361 361 361 361 378 378 378
UN
ITRO
NIC
® B
US
ASI (
G) y
ello
w +
bla
ck
fixed
inst
alla
tion/
flexi
ble
UN
ITRO
NIC
® B
US
ASI (
TPE)
yel
low
+ b
lack
fix
ed in
stal
latio
n/fle
xibl
e
UN
ITRO
NIC
® B
US
ASI L
D F
D P
ye
llow
+ b
lack
hi
ghly
flex
ible
app
licat
ion
UN
ITRO
NIC
® B
US
ASI F
D (T
PE) A
ye
llow
+ b
lack
hi
ghly
flex
ible
app
licat
ion
UN
ITRO
NIC
® B
US
ASI F
D P
FRN
C
yello
w +
bla
ck
fixed
inst
alla
tion
UN
ITRO
NIC
® B
US
ASI (
PVC
) A
yello
w +
bla
ck
fixed
inst
alla
tion
UN
ITRO
NIC
® D
evic
eNet
TH
ICK
+ TH
IN (h
alog
en-fr
ee)
fixed
inst
alla
tion
UN
ITRO
NIC
® D
evic
eNet
TH
ICK
+ TH
IN (P
VC)
fixed
inst
alla
tion
UN
ITRO
NIC
® D
evic
eNet
TH
ICK
+ TH
IN (P
UR)
hi
ghly
flex
ible
UN
ITRO
NIC
® D
evic
eNet
TH
ICK
+ TH
IN (P
VC)
high
ly fl
exib
le
UN
ITRO
NIC
® B
US
SAFT
EY
fixed
inst
alla
tion/
high
ly fl
exib
le
UN
ITRO
NIC
® B
US
EIB
fixed
inst
alla
tion
UN
ITRO
NIC
® B
US
EIB
CO
MBI
fixed
inst
alla
tion
Parameter
Characteristic impedance Ω – – – – – – 120 120 120 120 100- 200 – –
Mutual capacitance (800 Hz) max. nF/km – – – – – – 39.8 39.8 39.8 39.8 45 max. 100max. 100
Peak operating voltage V (not for power applications)
300 300 300 300 300 300 300 300 300 300 250 250 250
Test voltage, core/core, Ueff V 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 3000 4000 4000
Conductor resistance (loop) Data network cable pair max. Ω/km
27.4 27.4 16.5 27.4 27.4 27.4 THICK 45THIN 180THICK 45THIN 180
THICK 45THIN 180
THICK 45THIN 180 52
max. 130
max. 130
Minimum bending radius, fixed installation 3 x D 3 x D 3 x D 3 x D 3 x D 3 x D 10 x D 10 x D – – 8 x D 10 x D 10 x D
Minimum bending radius, flexing – – 6 x D 6 x D – – – – 10 x D 10 x D – – –
Temperature range from °Cfixed installation to °C
- 40 + 85
- 40 + 85
- 40 + 80
- 40 + 105
- 40 + 80
- 30 + 90
- 25 + 80
- 20 + 80 – –
- 40 + 80
- 30 + 70
- 30 + 70
Temperature range from °Cflexing to °C – –
- 30 + 70
- 30 + 105
- 30 + 70 – – –
- 40 + 80
- 10 + 80
- 30 + 80 – –
1078_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®1079_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®1080_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®1081_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®
top related