aa 250/425 thermal entrances 1 - mod4 …mod4distribution.com/pdf_files/kawneer specialty swing...

Post on 09-Aug-2018

213 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

1AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

FEATURES

For specific product applications,Consult your Kawneer representative.

Features

• AA®250 narrow stile has 2-1/2" vertical stiles, 2-1/2" top rail, and 3-7/8" bottom rail

• AA®425 wide stile has 4-1/4" vertical stiles, 4-1/4" top rail, and 6-1/2" bottom rail

• Dooris2-1/4"deep

• Doorhas1/8"typicalwallthickness

• Dualweldedcornerconstruction

• Singleacting

• Offsetpivots,butthingesorcontinuousgearedhinge

• Surfacemountedorconcealedclosers

• MSlocksorexitdevicehardware

• ArchitectsClassicpush/pulls

• 1"insulatedglassinfill

• Meetingstileastragalhasdualpileweatheringwithpolymericfin

• Sealair®bulbpolymericweatherstrippingandpileweatheringwithpolymericfinin

doorframe

• Permanodic® anodized finishes in seven choices

• Paintedfinishesinstandardandcustomchoices

Optional Features

• Numerouspush/pullfinishes

• Varietyoftop,bottom,andcrossrails

• Twocolorfinishcapability

Product Applications

• AA®250-engineeredforthermalefficiencyinmoderatetrafficapplicationssuchasoffices,

stores,andapartmentbuildings

• AA®425-engineeredforthermalefficiencyandaddedstrengthforschools,institutions

andotherincreasedtrafficapplications

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

2 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

BLANK PAGE

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

3AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

INDEX

PICTORIAL VIEW ............................................................................... 5

AA®250 THERMAL ENTRANCE CONSTRUCTION DETAILS ........... 6

AA®425 THERMAL ENTRANCE CONSTRUCTION DETAILS ........... 7

TRIFAB® VG 451T CENTER DOOR FRAMES ................................ 8-9

ENTRANCE OFFERING .............................................................. 10-11

PUSH PULL HARDWARE ................................................................ 12

EXIT DEVICES .................................................................................. 13

OPTIONS AND ACCESSORIES....................................................... 14

THERMAL CHARTS .................................................................... 15-27

LAWSANDBUILDINGANDSAFETYCODESGOVERNINGTHEDESIGNANDUSEOFGLAZEDENTRANCE,WINDOW,ANDCURTAINWALLPRODUCTSVARYWIDELY.KAWNEERDOESNOTCONTROLTHESELECTIONOFPRODUCTCONFIGURATIONS,OPERATINGHARDWARE,ORGLAZINGMATERIALS,ANDASSUMESNORESPONSIBILITYTHEREFOR.

Metric(SI)conversionfiguresareincludedthroughoutthesedetailsforreference.Numbersinparentheses()aremillimetersunlessotherwisenoted.

Thefollowingmetric(SI)unitsarefoundinthesedetails:

m – meter

cm – centimeter

mm – millimeter

s – second

Pa–pascal

MPa–megapascal

Kawneerreservestherighttochangeconfigurationswithoutpriornoticewhendeemednecessaryforproductimprovement.

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

4 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

BLANK PAGE

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

5AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

PICTORIAL VIEW

#1 MECHANICAL FASTENING is accomplished byattachinga5/16"(7.9)thickextrudedaluminum channel clip to the vertical stile with 1/4"-20 heat strengthenedboltsand3/16"thicksteelnutplates forahighstrengthweldingbaseforattachment horizontal member.

#2 SIGMA* DEEP PENETRATION PLUG WELDS aremadetopandbottomafterthehorizontal is properly positioned over the channel clip to helpprovidethestrongestdoorcornerjoint currently available.

#3 SIGMA* FILLET WELDSalongbothtopand bottomwebsoftherailextrusioncompletethe DualWeldedcornerconstruction.

* An arc welding process known as Shielded Inert Gas Metal Arc (SIGMA) or also known as Metal Inert Gas (MIG).

DUAL WELDED CORNER CONSTRUCTION

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

6 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

AA®250 THERMAL ENTRANCE CONSTRUCTION DETAILS

5TRANSOM HEAD

6DOOR HEADER/TRANSOM BAR

7*BOTTOM RAIL

*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.

SCALE 3" = 1'-0"

1BUTT HINGE JAMB

1AOFFSET PIVOT HINGE JAMB

2MEETING STILES

3LOCK JAMB

1BCONTINUOUS HINGE JAMB

4TRANSOM

INSERT

AA®250 THERMAL ENTRANCE DOORS SINGLE ACTING

TRIFAB® VG 451T CENTER DOOR FRAMES SHOWN

1 1A 1B

7

6

2

6

3

7

5

7 7

64

2 3

6

5

1 1A 1B

1 1A 1B

1 1A 1B

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

7AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

AA®425 THERMAL ENTRANCE CONSTRUCTION DETAILS

SCALE 3" = 1'-0"

5TRANSOM HEAD

6DOOR HEADER/TRANSOM BAR

7*BOTTOM RAIL

*NOTE: Some building codes limit threshold height to 1/2" (12.7) max.

1BUTT HINGE JAMB

1AOFFSET PIVOT HINGE JAMB

2MEETING STILES

3LOCK JAMB

1BCONTINUOUS HINGE JAMB

4TRANSOM

INSERT

AA®425 THERMAL ENTRANCE DOORS SINGLE ACTING

TRIFAB® VG 451T CENTER DOOR FRAMES SHOWN

1 1A 1B

7

6

2

6

3

7

5

7 7

64

2 3

6

5

1 1A 1B

1 1A 1B

1 1A 1B

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

1/8"

(3.2

)4-

1/4"

(108

.0)

2"

(50.

8)

1/4"

(6.4

)

2"

(50.

8)

1/4"

(6.4

)

6-1/

2"

(165

.1)

11/1

6"

(17.

5)

1/8"

(3.2

)4-

1/4"

(108

.0)

1-1/

8"

(28.

6)

2"

(50.

8)

6-1/

2"

(165

.1)

11/1

6"

(17.

5)

8 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

TRIFAB® VG 451T CENTER DOOR FRAMES

SCALE 3" = 1'-0"

TRIFAB® VG 451T CENTER DOOR FRAMES

MA

SO

NR

YO

PE

NIN

G

FR

AM

ED

IME

NS

ION

DO

OR

OP

EN

ING

DO

OR

HE

IGH

T

D.L

.O.

MA

SO

NR

YO

PE

NIN

G

FR

AM

ED

IME

NS

ION

DO

OR

OP

EN

ING

DO

OR

HE

IGH

T

D.L

.O.

SINGLE ACTING DOOR WITHOUT TRANSOM

SINGLE ACTING DOOR WITH TRANSOM

D.L

.O.

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

2"

(50.8)

4-1/4"

(108.0)3/32"

(2.4)

1/4"

(6.4)

4-5/16"

(109.6)

4-1/4"

(107.9)

2"

(50.8)

1/4"

(6.4)

4-1/4"

(108.0)3/32"

(2.4)

1/4"

(6.4)

2"

(50.8)

1/4"

(6.4)

4"

(101.5)11/32"

(8.9)

9AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

TRIFAB® VG 451T CENTER DOOR FRAMES

SCALE 3" = 1'-0"

MASONRYOPENING

FRAMEDIMENSION

DOOROPENING

DOORHEIGHT

D.L.O.

DOORHEIGHT

D.L.O.

SINGLE ACTING DOOR

MASONRYOPENING

FRAMEDIMENSION

DOOROPENING

DOORHEIGHT

D.L.O.

CONTINUOUS HINGE JAMB

STANDARD SIZE TRIFAB® VG 451T CENTER DOOR FRAMES WITHOUT TRANSOM

Door Opening Dimension3'1/2"x7'0"(927.1x2134)3'6"x7'0"(1066.8x2134)6'0"x7'0"(1829x2134)

Overall Frame Dimension3'4"x7'1-3/4"(1016x2178)

3'9-1/2"x7'1-3/4"(1155.7x2178)6'3-1/2"x7'1-3/4"(1918x2178)

Masonry Opening Dimension3'4-1/2"x7'2"(1028.7x2185)

3'10"x7'2"(1168.4x2185)6'4"x7'2"(1930x2185)

Door Opening DimensionUnchangedfromabove

WITH TRANSOMOverall Frame Dimension

Add3'1-3/4"(959)toaboveheightsMasonry Opening Dimension

Add3'1-3/4"(959)toaboveheights

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

10 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

ENTRANCE OFFERINGS

OPTIONALSTANDARD

Door Sizes StandardsizesshownonPage10. Anysizeupto3'-6"x8'-0"(1067x2438)

Glass Stops Squareglassstopsfor1"(25.4)infill.

Door Frames •Trifab®VG451TCenter-2"x4-1/2"(50.8x114.3) fordoubleglazing.

Push-Pulls Single Acting:•ArchitectsClassicStyle"CO-9"Pulland"CP-II" Pushbar.•ArchitectsClassicStyle"CO-9"Pulland"CP"Pushbar.

Single Acting:•ArchitectsClassicStyle"CO-12"Pulland"CP-II" Pushbar.•ArchitectsClassicStyle"CO-12"Pulland"CP" Pushbar.•ArchitectsClassicStyle"CO-9"/"CO-9"Pull.•ArchitectsClassicStyle"CO-12"/"CO-12"Pull.

Door Closers Single Acting:•Norton1601adjustableor1601BFadjustablesurfacecloser withback-check,andwithorwithouthold-open.

Single Acting:•LCN1260adjustable•LCN4040surfacecloserwithorwithoutadjustable hold-open.•StandardCOCwith singleactingoffsetarm.•Norton8100surfacecloserwith50%springpower adjustment(foropeningforcesoflessthan8pounds.) Closerisavailablewithstandardback-checksandwith orwithoutthehold-openfeature.•Door-O-Matic/FalconSC60surfacecloser.

Pivots / Butts Single Acting:•Kawneertopandbottomoffsetpivots.•Kawneertopandbottom4-1/2"x4"(114.3x101.6) ballbearingbutthingewithnon-removablepin(NRP).•ContinuousHinge.

IntermediatePivots / Butts

Single Acting:• Kawneer optional intermediate pivot.•Kawneer4-1/2"x4"(114.3x101.6)ballbearingbutt hingewithnon-removablepin(NRP).

Power Transfers

Locks(Active Leaf)

Adams-RiteMS1850ADeadlockwithtwo1-5/32"(29.4)diameter 5 pin cylinders.

•Adams-Rite#4510LatchLock.•Adams-Rite#1850A-500ShortthrowDeadlock.•Adams-Rite#1850A-505HookboltLock.•Adams-Rite#4015Two-pointLock.•Adams-Rite#4015&4016Three-pointLock.•Adams-Rite#4089ExitIndicator.•Adams-Rite#7130ElectricStrike.•KawneerCylinderGuard.•KawneerThumbturn(inlieuofcylinder).

Power Supply •SP1000PowerSupply

Single Acting:•Kawneeroptionalintermediatepivotwithwiretransfer.•Kawneerstandard(4-1/2"x4")(114.3x101.6)ball bearing(NRP)butthingewithwiretransfer.•EPT(ElectricPowerTransfer)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

11AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

ENTRANCE OFFERINGS

Locks(Inactive Leaf)

OnepairofKawneerflushboltsintheinactiveleafofapairofdoors.

Threshold A1/2"x4-1/2"(12.7x114.3)aluminummillfinishthreshold.

Weathering SEALAIR® Weathering system in the door and frameconsistingofadense,bulbpolymericmaterial,whichremainsresilientandretainsitsweatheringabilityundertemperatureextremes.CompletewithanEPDMbladegasketsweepstripappliedtoboththeinteriorandexteriorofthebottomrailwithconcealedfasteners.

Exit Devices •Kawneer1686concealedrodexitdevicewith or without a rim type cylinder.

•Kawneer1786rimtypeexitdevicewithor without a rim type cylinder.

•Adams-Rite8600concealedrodexitdevice.

•Adams-Rite8400rimexitdevice.

•Dor-O-Matic/Falcon1690concealedrodexitdevicewith or without a rim type cylinder.

•Dor-O-Matic/Falcon1790rimtypeexitdevicewithor without a rim type cylinder.

•Dor-O-Matic/FalconEL1690concealedrodexitdevice withorwithoutarimtypecylinder.Thedeviceisdesigned forelectrifiedaccesscontrolandiscompatiblewithmost keypadandcardreadersystems.

•Dor-O-Matic/FalconEL1790rimtypeexitdevicewithor withoutarimtypecylinder.Thedeviceisdesignedfor electrifiedaccesscontrolandiscompatiblewithmostkey pad and card reader systems.

•Dor-O-Matic/Falcon1990isaconcealedrodexitdevice with or without a rim type cylinder.

•Dor-O-Matic/Falcon2090isarimtypeexitdevicewith or without a rim type cylinder.

•VonDuprin33concealedrodexitdevicewithorwithout nightlatchassembly.

•VonDuprin99concealedrodexitdevicewithorwithout nightlatchassembly.

Exit Device Pulls

•ArchitectsClassicstyle"CO-9"Pull.•ArchitectsClassicstyle"CPN"PullforPaneline® and Paneline®ELexitdevices.

Exit Device Pulls

•ArchitectsClassicstyle"CO-12"Pull (except forPaneline®andPaneline®ELexitdevices).

OPTIONALSTANDARD

Reference Hardware section for additional information

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

12 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

PUSH-PULL HARDWARE

ARCHITECTS CLASSIC (PUSH-PULL SETS)SINGLEACTINGDOORSUSEAPULLHANDLEANDPUSHBAR.

RefertoHARDWARE SECTIONforcompletehardwareinformation.

CO-9 / CP-IICO-12 / CP-II

CO-9 / CPCO-12 / CP

CP-II / CP-II CP / CP

CO-9 / CO-9CO-12 / CO-12

ARCHITECTS CLASSIC (COMPONENTS)

"CO-9"PULL

"CO-12"PULL

"CP-II" PUSH BAR "CP" PUSH BAR

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

13AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

EXIT DEVICES and EXIT DEVICE PULLS

"CO-9"PULL

"CO-12"PULL

CONCEALED ROD EXIT DEVICEDor-O-Matic/Falcon 1990

RIM LATCH EXIT DEVICEDor-O-Matic/Falcon 2090

CONCEALED ROD EXIT DEVICEDor-O-Matic/Falcon 1690

Dor-O-Matic/Falcon EL 1690

RIM LATCH EXIT DEVICEDor-O-Matic/Falcon 1790

Dor-O-Matic/Falcon EL 1790

CONCEALED ROD EXIT DEVICEKawneer 1686

RIM LATCH EXIT DEVICEKawneer 1786

MORTISE EXIT DEVICE Adams-Rite 8400 CONCEALED EXIT DEVICE

Adams-Rite 8600

CONCEALED EXIT DEVICE Von Duprin 3347A CONCEALED EXIT DEVICE

Von Duprin 9947

EXIT DEVICES

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

10"

[254

.0]

1-3/

8"

(34.

9)

8-1/

4"

(209

.6)

1/2"

(12.7)

1"

(25.

4)

2-15

/32"

(62.

7)

069-177

1/2"

(12.7)

11/1

6"

(17.

5)

2-15

/32"

(62.

7)

069-154

14 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

10" BOTTOM RAIL

APPLIED DOOR STOP

APPLIED DOOR STOP

OPTIONS AND ACCESSORIES

1-3/8" CROSSRAIL 8-1/4" CROSSRAIL

SCALE 3" = 1'-0"

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.49

66%

0.480.460.440.420.400.380.360.340.320.300.280.260.240.220.20

0.70

0.80

0.60

0.50

0.40

0.30

0.2085 80 75 70 65 60

0.75

0.65

0.55

0.45

0.35

0.25

(2.73)(2.61)(2.50)(2.39)(2.27)(2.16)(2.05)(1.93)(1.82)(1.71)(1.59)(1.48)(1.37)(1.25)(1.14)

0.90

0.85

7'-2

"(2

184.

4)

3'-4"(1016.0)

30.125"(765.2)

75.7

5"(1

924.

1)

15AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

THERMAL CHARTS

Project Specific U-Factor Example Calculation

ExampleGlassU-Factor =0.28Btu/hr•ft2•°F

TotalDaylightOpening =30.125"x75.75"=15.85ft2

TotalProjectedArea =3'-4"x7'-2"=23.9ft2

PercentofGlass =(TotalDaylightOpening÷TotalProjectedArea)100 =(15.85÷23.9)100=66%

System U-factor vs Percent of Glass Area

EXAMPLE

NOT FOR DESIGN

COGU-factor

Percent of Glass Area

Basedon66%glassandcenterofglass(COG)U-factorof0.28SystemU-factorisequalto0.49Btu/hr•ft2•°F

Btu

hr

•ft

2 •

°FS

yste

m U

-fac

tor

(DLO)

(DLO

)

(F.W.)

(F.H

.)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.47(2.67)0.46(2.61)0.44(2.50)0.42(2.39)0.40(2.27)0.38(2.16)

0.36(2.05)

0.34(1.93)0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)0.24(1.37)

0.22(1.25)0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

16 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

AA®250 (SINGLE DOOR)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

17AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

AA®250 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.57

0.57

0.55

0.54

0.53

0.52

0.51

0.50

0.49

0.48

0.47

0.46

0.45

0.44

0.43

0.42

0.41

0.40

0.39

0.38

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.43

0.40

0.37

0.34

0.31

0.29

0.26

0.23

0.20

0.17

0.14

0.11

0.09

0.06

0.03

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.45

0.42

0.39

0.36

0.34

0.31

0.28

0.25

0.22

0.19

0.16

0.13

0.11

0.08

0.05

18 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolation is permitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof960mmwideby 2090mmhigh(37-3/4"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AA®250 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.47(2.67)0.46(2.61)

0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)

0.36(2.05)

0.34(1.93)

0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

19AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

AA®250 (PAIR OF DOORS)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

20 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

AA®250 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.56

0.55

0.54

0.53

0.52

0.51

0.50

0.49

0.48

0.46

0.45

0.44

0.43

0.42

0.41

0.39

0.38

0.37

0.36

0.35

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.46

0.43

0.40

0.37

0.34

0.31

0.28

0.25

0.21

0.18

0.15

0.12

0.09

0.06

0.03

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.48

0.45

0.42

0.39

0.36

0.32

0.29

0.26

0.23

0.20

0.17

0.14

0.11

0.08

0.05

21AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolation is permitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof1920mmwideby 2090mmhigh(75-1/2"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AA®250 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.47(2.67)0.46(2.61)0.44(2.50)0.42(2.39)0.40(2.27)0.38(2.16)0.36(2.05)0.34(1.93)0.32(1.82)0.30(1.71)0.28(1.59)0.26(1.48)0.24(1.37)0.22(1.25)0.20(1.14)0.18(1.02)0.16(0.91)0.14(0.80)0.12(0.68)0.10(0.57)

22 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

AA®425 (SINGLE DOOR)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

23AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

AA®425 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.58

0.58

0.57

0.56

0.55

0.54

0.53

0.52

0.51

0.51

0.50

0.49

0.48

0.47

0.46

0.44

0.43

0.43

0.42

0.41

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.36

0.34

0.32

0.29

0.27

0.24

0.22

0.19

0.17

0.15

0.12

0.10

0.07

0.05

0.02

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.39

0.36

0.34

0.32

0.29

0.27

0.24

0.22

0.19

0.17

0.15

0.12

0.10

0.07

0.05

24 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolation is permitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof960mmwideby 2090mmhigh(37-3/4"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AA®425 (SINGLE DOOR)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.47(2.67)0.46(2.61)

0.44(2.50)

0.42(2.39)

0.40(2.27)

0.38(2.16)0.36(2.05)

0.34(1.93)0.32(1.82)

0.30(1.71)

0.28(1.59)

0.26(1.48)

0.24(1.37)

0.22(1.25)

0.20(1.14)

0.18(1.02)

0.16(0.91)

0.14(0.80)

0.12(0.68)

0.10(0.57)

25AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

AA®425 (PAIR OF DOORS)

System U-factor vs Percent of Glass Area

Sys

tem

U-f

acto

r (B

TU

/hr·

ft2 ·

oF

)

Percent of Glass = Vision Area/Total Area(Total Daylight Opening / Projected Area)

COGU-factor

Notes for System U-Factor, SHGC and VT charts: Forglassvaluesthatarenotlisted,linearinterpolationispermitted. Glasspropertiesarebasedoncenterofglassvalues(winterconditions)andareobtained fromyourglasssupplier.

THERMAL CHARTS

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

26 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

THERMAL CHARTS

System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area

Sys

tem

SH

GC

Vision Area / Total Area (%)

COGSHGC

System Visible Transmittance (VT) vs Percent of Vision Area

Sys

tem

VT

Vision Area / Total Area (%)

COGVT

AA®425 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

0.48

0.46

0.44

0.42

0.40

0.38

0.36

0.34

0.32

0.30

0.28

0.26

0.24

0.22

0.20

0.18

0.16

0.14

0.12

0.10

0.57

0.57

0.56

0.55

0.54

0.53

0.52

0.51

0.50

0.49

0.48

0.47

0.46

0.45

0.44

0.43

0.42

0.41

0.40

0.39

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.39

0.37

0.34

0.32

0.29

0.26

0.24

0.21

0.18

0.16

0.13

0.11

0.08

0.05

0.03

0.75

0.70

0.65

0.60

0.55

0.50

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.42

0.39

0.36

0.34

0.31

0.28

0.26

0.23

0.21

0.18

0.15

0.13

0.10

0.07

0.05

27AA®250/425 THERMAL ENTRANCESSEPTEMBER, 2012

NOTE:Forglassvaluesthatarenotlisted,linear interpolation is permitted.

1. U-FactorsaredeterminedinaccordancewithNFRC100.2. SHGCandVTvaluesaredeterminedinaccordancewith NFRC200.3. Glasspropertiesarebasedoncenterofglassvalues (winterconditions)andareobtainedfromyourglasssupplier.4. OverallU-Factor,SHGC,andVTMatriciesarebasedon thestandardNFRCspecimensizeof1920mmwideby 2090mmhigh(75-1/2"by82-3/8").

Thermal Transmittance 1 (BTU/hr•ft2•°F)

SHGC Matrix 2 Visible Transmittance 2

Glass U-Factor 3 Overall U-Factor 4

Glass VT 3 Overall VT 4Glass SHGC 3 Overall SHGC 4

THERMAL PERFORMANCE MATRIX (NFRC SIZE)

AA®425 (PAIR OF DOORS)

Law

s an

d b

uild

ing

and

saf

ety

cod

es g

over

ning

the

des

ign

and

use

of g

laze

d

entr

ance

, win

dow

, and

cur

tain

wal

l pro

duc

ts v

ary

wid

ely.

Kaw

neer

doe

s no

t co

ntro

l th

e se

lect

ion

of p

rod

uct

confi

gura

tions

, op

erat

ing

hard

war

e, o

r gl

azin

g m

ater

ials

, an

d a

ssum

es n

o re

spon

sib

ility

the

refo

r.

Kaw

neer

res

erve

s th

e rig

ht t

o ch

ange

con

figur

atio

n w

ithou

t p

rior

notic

e w

hen

dee

med

nece

ssar

y fo

r p

rod

uct

imp

rove

men

t.

© K

awne

er C

omp

any,

Inc.

, 201

2

kawneer.com

EC 97911-46

28 AA®250/425 THERMAL ENTRANCES SEPTEMBER, 2012

top related